首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
A highly sensitive and selective liquid chromatography–atmospheric pressure chemical ionization tandem mass spectrometry assay was developed and validated for simultaneous determination of epimeric budesonide (BUD) and fluticasone propionate (FP) in plasma. The drugs were isolated from human plasma using C18 solid-phase extraction cartridges, and epimeric BUD was acetylated with a mixture of 12.5% acetic anhydride and 12.5% triethylamine in acetonitrile to form the 21-acetyl derivatives following the solid-phase extraction. Deuterium-labelled BUD acetate with an isotopic purity >99% was synthesized and used as the internal standard. The assay was linear over the ranges 0.05–10.0 ng/ml for epimeric BUD, and 0.02–4.0 ng/ml for FP. The inter- and intra-day relative standard deviations were <14.3% in the assay concentration range.  相似文献   

2.
A rapid, sensitive and accurate liquid chromatographic-tandem mass spectrometric method is described for the determination of tamsulosin in dog plasma. Tamsulosin was extracted from plasma using a mixture of hexane-ethyl acetate (2:1, v/v) and separated on a C18 column interfaced with a triple quadrupole tandem mass spectrometer. The mobile phase consisting of a mixture of methanol, water and formic acid (80:20:1, v/v/v) was delivered at a flow rate of 0.5 ml/min. Atmospheric pressure chemical ionization (APCI) source was operated in positive ion mode. Selected reaction monitoring (SRM) mode using the transitions of m/z 409-->m/z 228 and m/z 256-->m/z 166.9 were used to quantify tamsulosin and the internal standard, respectively. The linearity was obtained over the concentration range of 0.1-50.0 ng/ml for tamsulosin and the lower limit of quantitation was 0.1 ng/ml. For each level of QC samples, inter- and intra-run precision was less than 5.0 and 4.0% (relative standard deviation (R.S.D.)), respectively, and accuracy was within +/-0.3% (relative error (R.E.)). This method was successfully applied to pharmacokinetic study of a tamsulosin formulation product after oral administration to beagle dogs.  相似文献   

3.
Rapid resolution liquid chromatography/tandem multi-stage mass spectrometry (RRLC-MS(n)) and rapid resolution liquid chromatography/tandem mass spectrometry (RRLC/MS/MS) methods were developed for the identification and quantification of ergosterol and its metabolites from rat plasma, urine and faeces. Two metabolites (ERG1 and ERG2) were identified by RRLC/MS(n). The concentrations of the ergosterol were determined by RRLC/MS/MS. The separation was performed on an Agilent Zorbax SB-C18 with the mobile phase consisting of methanol and water (containing 0.1% formic acid). The detection was carried out by means of atmospheric pressure chemical ionization mass spectrometry in positive ion mode with multiple reaction monitoring (MRM). Linear calibration curves were obtained in the concentration range of 7-2000, 6-2000 and 8-7500 ng/mL for plasma, urine and faecal homogenate, respectively. The intra- and inter-day precision values (RSD) were below 10%. The method was applied to the pharmacokinetic properties and elimination pathway of ergosterol in rats.  相似文献   

4.
A highly sensitive and enantioselective assay has been developed and validated for the estimation of torcetrapib (TTB) enantiomers [(+)-TTB and (-)-TTB] in hamster plasma with chiral liquid chromatography coupled to tandem mass spectrometry with an atmospheric pressure chemical ionization interface in the negative-ion mode. The assay procedure involves liquid-liquid extraction of TTB enantiomers and IS (DRL-16126) from 100 microL hamster plasma with acetonitrile. TTB enantiomers were separated using n-hexane:propanol (80:20, v/v) at a flow rate of 0.7 mL/min on a Chiralpak AD column. The MS/MS ion transitions monitored were 599.2-->340.2 for TTB and 623.2-->298.1 for IS. Absolute recovery was found to be between 64 and 68% for TTB enantiomers and >100% for IS. The standard curves for TTB enantiomers were linear (r(2)>0.995) in the concentration range 5-2500 ng/mL for each enantiomer with an LLOQ of 5 ng/mL for each enantiomer. The inter- and intra-day precisions were in the range of 10.5-12.4 and 9.15-11.5% and 3.75-12.9 and 5.16-12.5% for (+)-TTB and (-)-TTB, respectively. Accuracy in the measurement of quality control (QC) samples was in the range 91.3-105 and 88.6-111% for (+)-TTB and (-)-TTB, respectively. This novel method has been applied to the study of stereoselective oral pharmacokinetics of (-)-TTB.  相似文献   

5.
A sensitive, specific, accurate and reproducible LC-MS-MS method was developed and validated for the simultaneous determination of rivastigmine and its major metabolite NAP 226-90 in human plasma according to International Regulatory Requirements. After addition of their respective labelled internal standards, the compounds were extracted from plasma using methyl-tert.-butyl ether at basic pH with a simultaneous derivatization of NAP 226-90 with propionic anhydride, and backextracted into an acidic solution. After re-extraction the compounds were analyzed on a 3-micrometer Purospher Star RP-18 column interfaced with a MDS Sciex API 3000 triple quadrupole mass spectrometer. Positive atmospheric chemical ionization was employed as the ionization source. The analytes and their internal standards were detected by use of multiple reaction monitoring mode. Intra- and inter-day accuracy and precision were found suitable over the range of concentrations between 0.200 and 30.0 ng/ml. The LC-MS-MS method was crossvalidated with a previously developed in-house GC-MS method by the analysis of plasma samples obtained from patients after administration of Exelon((R)) capsules and showed excellent correlation between the methods.  相似文献   

6.
A highly sensitive and selective HPLC-MS-MS method was developed for the determination of pramipexole in human plasma. The analytes, pramipexole and BHT-920 (internal standard), were extracted from plasma at basic pH with methyl tert.-butyl ether (MTBE). MTBE was evaporated to dryness and reconstituted in 100 μl of (95:5) methanol-water. Chromatographic separation was achieved on a Zorbax SB-CN column with a mobile phase of (15:5:80) water-0.1 M ammonium acetate—methanol. The analytes were detected utilizing HPLC in conjunction with atmospheric pressure chemical ionization (APCI) tandem mass spectrometry (MSM). The assay was linear in the concentration ranges of 50 to 5000 pg/ml. The analysis of pooled quality controls (150, 750, and 3000 pg/ml) demonstrated excellent precision with relative standard deviations (R.S.D.) (n=18) of 7.2%, 5.3% and 5.2%, respectively. The method is accurate with all intra-day (n=6) and overall (n=18) mean values being less than 11.7% from theoretical.  相似文献   

7.
A specific LC-MS/MS assay was developed for the automated determination of talinolol in human plasma, using on-line solid phase extraction system (prospekt 2) combined with atmospheric pressure chemical ionization (APCI) tandem mass spectrometry. The method involved simple precipitation of plasma proteins with perchloric acid (contained propranolol) as the internal standard (IS) and injection of the supernatant onto a C8 End Capped (10 mmx2 mm) cartridge without any evaporation step. Using the back-flush mode, the analytes were transferred onto an analytical column (XTerra C18, 50 mmx4.6 mm) for chromatographic separation and mass spectrometry detection. One of the particularities of the assay is that the SPE cartridge is used as a column switching device and not as an SPE cartridge. Therefore, the same SPE cartridge could be used more than 28 times, significantly reducing the analysis cost. APCI ionization was selected to overcome any potential matrix suppression effects because the analyte and IS co-eluted. The mean precision and accuracy in the concentration range 2.5-200 ng/mL was found to be 103% and 7.4%, respectively. The data was assessed from QC samples during the validation phase of the assay. The lower limit of quantification was 2.5 ng/mL, using a 250 microL plasma aliquot. The LC-MS/MS method provided the requisite selectivity, sensitivity, robustness accuracy and precision to assess pharmacokinetics of the compound in several hundred human plasma samples.  相似文献   

8.
We established a method for precisely determining residual tetracycline antibiotics (TCs) in foods by atmospheric pressure chemical ionization liquid chromatography-tandem mass spectrometry (APCI LC–MS–MS) using selected reaction monitoring with an internal standard. By setting the nebulizer probe temperature to 475°C, we were able to use a mobile phase containing oxalic acid without clogging problems at the APCI interface, since oxalic acid decomposes to carbon dioxide and water at high temperature. DMCTC was very effective as an internal standard for determining TCs in various foods. TCs were cleaned up using a Bond Elut ENV cartridge and analysed by APCI LC–MS–MS. The recovery of TCs from various foods including animal tissues, honey, milk, eggs, and fish fortified at levels of 0.05, 0.10, and 0.50 ppm averaged 60.1–88.9%, with an RSD of 1.2–8.7%. The detection limits were 0.001 ppm for OTC and TC, 0.004 ppm for CTC, and 0.002 ppm for DC. The present method was also successfully used to determine TCs in swine kidney samples that were previously found by microbiological assay.  相似文献   

9.
Free carnitine and acylcarnitines play an important role in the metabolism of fatty acids. Sterols are structural lipids found in the membranes of many eukaryotic cells, and they also have functional roles such as the regulation of membrane permeability and fluidity, activity of membrane-bound enzymes and signals transduction. Abnormal profiles of these compounds in biological fluids may be useful markers of metabolic changes. In this review, we describe the subset of the lipidome represented by acylcarnitines and sterols, and we summarize how these compounds have been analyzed in the past. Over the last 50years, lipid mass spectrometry (MS) has evolved to become one of the most useful techniques for metabolic analysis. Today, the introduction of new ambient ionization techniques coupled to MS (AMS), which are characterized by the direct desorbing/ionizing of molecules from solid samples, is generating new possibilities for in situ analysis. Recently, we developed an AMS approach called APTDCI to desorb/ionize using a heated gas flow and an electrical discharge to directly analyze sterols and indirectly investigate acylcarnitines in dried blood or plasma spot samples. Here, we also describe the APTDCI method and some of its clinical applications, and we underline the common complications and issues that remain to be resolved.  相似文献   

10.
A liquid chromatography–atmospheric pressure chemical ionization tandem mass spectrometry (LC–APCI-MS–MS) method is described for the determination of a thromboxane receptor antagonist (4Z)-6-((2S,4S,5R)-2-(1-(2-cyano-4-methylphenoxy)-1-methylethyl)-4-(3-pyridyl)-3-dioxan-5-yl)hex-4-enoic acid (ZD9583, I) in human plasma and urine. Proteins in plasma and urine samples are precipitated using acidified acetonitrile. The resulting supernatant is chromatographed on a C8 reversed-phase chromatography column. Following the diversion of the solvent front from the mass spectrometer by a switching valve, the column eluate is passed on to the mass spectrometer via a heated nebulizer interface where the analyte is detected by multiple reaction monitoring (MRM). The method has a chromatographic run time of less than 2 min, a linear calibration curve with a range of 1–500 ng ml−1 and intra- and inter-day precision estimates of less than 10% over the calibration range.  相似文献   

11.
An enantioselective assay of omeprazole in blood plasma using normal-phase liquid chromatography on a Chiralpak AD column and detection by mass spectrometry is described. Omeprazole is extracted by a mixture of dichloromethane and hexane and, after evaporation, redissolution and injection, separated into its enantiomers on the chiral stationary phase. Detection is made by a triple quadrupole mass spectrometer, using deuterated analogues as internal standards. The method enables determination in plasma down to 10 nmol/l (LOQ) and shows excellent consistency suited for pharmacokinetic studies in man.  相似文献   

12.
The levels of estrogens and/or their metabolites play important roles in carcinogenesis, reproductive function, and sexual development during perinatal and adolescence periods. The main purpose of this report was to investigate the applicability of high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) with electrospray ionization (ESI) and/or atmospheric pressure chemical ionization (APCI) for simultaneous detection of estrone (E1) and its six metabolites. Both positive and negative ionization modes in ESI and APCI were used to evaluate the signal responses of seven target analytes. Among the seven target analytes, five analytes, E1, 16alpha-hydroxyestrone, 2-methoxyestrone, 4-methoxyestrone, and 2-hydroxyestrone-3-methyl, produced signals with the best signal-to-noise (S/N) ratios in positive APCI-MS/MS mode, while the other two analytes, 2-hydroxyestrone and 4-hydroxyestrone, yielded the best S/N ratios in negative ESI-MS/MS mode. Based on the results of the evaluation, HPLC-APCI-MS/MS with switching between positive and negative modes was recommended for simultaneous detection of E1 and its six metabolites. The proposed analytical scheme was successfully applied in the analysis of cell culture medium of Human liver carcinoma cells treated with varying amounts of 2,3,7,8-tetrachlorodibenzo-p-dioxin.  相似文献   

13.
A simple and sensitive liquid chromatography/tandem mass spectrometry (LC-MS/MS) method using an atmospheric pressure chemical ionization source (APCI) for the quantification of fenretinide (4-HPR) in mouse plasma was developed and validated. After a simple protein precipitation of plasma sample by acetonitrile, 4-HPR was analyzed by LC-APCI-MS/MS. High-performance liquid chromatography (HPLC) separation was conducted on a Hypurity C18 column (50mmx2.1mm, 5microm) with a flow rate 0.60mL/min using a gradient mobile phase comprised of 0.05% formic acid in water (A) and methanol (B), and a run time of 4.5min. The elimination of a tedious sample preparation process and a shorter run time substantially reduced total analysis time. The method was linear over the range 0.5-100ng/mL, with r>0.998. The intra- and inter-assay precisions were 1.4-9.2% and 5.1-8.2%, respectively, and the intra- and inter-assay accuracies were 93.9-98.6% and 92.7-95.3%, respectively. The absolute recoveries were 90.3% (1.5ng/mL), 97.0% (7.5ng/mL) and 92.1% (75.0ng/mL) for 4-HPR, and 99.1% for the internal standard (150ng/mL). The analytical method had excellent sensitivity using a small sample volume (30microL) with the lower limit of quantification (LLOQ) 0.5ng/mL. This method is robust and has been successfully employed in a pharmacokinetic study of 4-HPR in a mouse xenograft model of neuroblastoma.  相似文献   

14.
A high-performance liquid chromatography tandem atmospheric pressure chemical ionization mass spectrometry method (HPLC-APCI-MS) has been developed for the characterization of astragalosides in the extracts of the roots of Astragalus spp. The [M - H](-) ions of astragalosides could be clearly observed in selected ion monitoring mode and APCI-MS-MS was used to further identify the structures of the astragalosides. Twelve astragalosides in the extracts of Radix Astragali obtained from Shandong in China were separated and identified. Using this method, astragalosides could be clearly identified and the profiles of these astragalosides could also be used to distinguish Astragalus spp. from different habitat regions.  相似文献   

15.
A method has been developed for the rapid determination of sugars, including molecular weight measurements, using high-performance liquid chromatography coupled with negative-ion, atmospheric-pressure chemical-ionization mass spectrometry. The chromatography was carried out on a 250 × 4 mm I.D. column packed with 7 μm NH2-silica. The mobile phase consisted of a high percentage of methanol or acetonitrile with a small amount of chloroform. During the mass spectrometry, a strong base is formed from the polar solvent molecules by corona discharge, followed by ion—molecule reactions in the chemical ionization ion source (e.g. the methoxy anion is formed from methanol). This strong base reacts with the chloroform, generating chloride ions, which in turn react with the neutral sugar molecules as they elute from the chromatograph. The chloride ion and sugar interactions yield chloride-attachment ions, which are further stabilized by successive collisions. In this method, authentic monosaccharides and some oligosaccharides show dominant quasi-molecular ions, [M + Cl], with little fragmentation, and it is particularly useful for the molecular weight determination of sugars.  相似文献   

16.
We developed a new method for the rapid determination of urinary organic acids using liquid chromatography—atmospheric pressure chemical ionization mass spectrometry. Mass spectra of authentic organic acids obtained in the negative-ion mode showed intense [M − H] ions with some fragment ions. Urine samples of patients with methylmalonic aciduria, ornithine transcarbamylase deficiency, and phenylketonuria were extracted using anion-exchange columns. The mass chromatograms of the extracts showed some dominant peaks of abnormal metabolites characteristic of each disorder. This is a useful method for the analysis of urinary organic acids for the diagnosis of organic aciduria, because the sample preparation is simple.  相似文献   

17.
A selective assay of olanzapine with liquid chromatography atmospheric pressure chemical ionization (LC–APCI–MS, positive ions) is described. The drug and internal standard (ethyl derivative of olanzapine) were isolated from serum using a solid-phase extraction procedure (C18 cartridges). The separation was performed on ODS column in acetonitrile–50 mM ammonium formate buffer, pH 3.0 (25:75). After analysis of mass spectra taken in full scan mode, a selected-ion monitoring detection (SIM) was applied with the following ions: m/z 313 and 256 for olanzapine and m/z 327 and 270 for the internal standard for quantitation. The limit of quantitation was 1 μg/l, the absolute recovery was above 80% at concentration level of 10 to 100 μg/l. The method tested linear in the range from 1 to 1000 μg/l and was applied for therapeutic monitoring of olanzapine in the serum of patients receiving (Zyprexa™) and in one case of olanzapine overdose. Olanzapine in frozen serum samples and in frozen extracts was stable over at least four weeks. The examinations of urine extracts from patients receiving olanzapine revealed peaks of postulated metabolites (glucuronide and N-desmethylolanzapine).  相似文献   

18.
Analytical conditions for underivatized glycosphingolipids by using high-performance liquid chromatography atmospheric pressure ionization mass spectrometry (HPLC/API-MS) were investigated. The analysis was performed by using an ordinary reversed-phase column (4.6 X 150 or 4.6 X 250 mm) at a flow rate of 1 ml/min. The glycosphingolipids could be characterized from the HPLC/API-MS in terms of molecular weight, ceramide composition, and partial oligosaccharide sequence. In order to obtain an adequate spectrum the amount of material needed is in the range of a few micrograms of lipid. By selected ion monitoring the sensitivity of the method allowed characterization of only 60 ng of glycosphingolipid. The method will be very useful in the characterization of small quantities of glycosphingolipids from biological samples.  相似文献   

19.
A sensitive and specific liquid chromatography electrospray ionization mass spectrometry (LC-ESI-MS) method has been developed and validated for the identification and quantification of zolmitriptan in human plasma. After the addition of the internal standard (IS) and 1.0 M sodium hydroxide solution, plasma samples were extracted with methylene chloride:ethyl acetate mixture (20:80, v/v). The organic layer was evaporated under a stream of nitrogen at 40 degrees C. The residue was reconstituted with 100 microl mobile phase. The compounds were separated on a prepacked Lichrospher CN (5 microm, 150 mm x 2.0 mm) column using a mixture of methanol:water (10 mM NH(4)AC, pH 4.0) = 78:22 as mobile phase. Detection was performed on a single quadrupole mass spectrometer by selected ion monitoring (SIM) mode via electrospray ionization (ESI) source. The method was proved to be sensitive and specific by testing six different plasma batches. Linearity was established for the range of concentrations 0.30-16.0 ng/ml with a coefficient of determination (r) of 0.9998 and good back-calculated accuracy and precision. The intra- and inter-day precision (R.S.D.%) were lower than 15% and accuracy ranged from 85 to 115%. The lower limit of quantification was identifiable and reproducible at 0.30 ng/ml. The proposed method enables the unambiguous identification and quantification of zolmitriptan for pharmacokinetic, bioavailability or bioequivalence studies.  相似文献   

20.
Isosorbide 5-mononitrate (5-ISMN) is an organic nitrate widely used for its vasodilating properties in the treatment of angina pectoris. In the present study, an efficient, sensitive, robust method was developed for the determination and quantification of isosorbide 5-mononitrate, in human plasma, by liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS), using photospray ionization. Isosorbide 5-mononitrate was extracted from 0.5 mL human plasma by liquid-liquid extraction (LLE). The method had a chromatographic run of 2.0 min using a C(8) analytical column (100 mm x 2.1 mm i.d.) and the linear calibration curve over the range was linear from 20 to 2000 ng mL(-1) (r(2)>0.995). The between-run precision, based on the relative standard deviation replicate quality controls, was 7.9% (60 ng mL(-1)), 5.2% (300 ng mL(-1)) and 7.0% (1800 ng mL(-1)). The between-run accuracy was 94.9%, 94.1% and 88.8% for the above-mentioned concentrations, respectively. The method herein described was employed in a bioequivalence study of two tablet formulations of isosorbide 5-mononitrate 40 mg.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号