首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
Matrix-assisted laser desorption/ionisation (MALDI) mass spectrometry (MS) is a highly versatile and sensitive analytical technique, which is known for its soft ionisation of biomolecules such as peptides and proteins. Generally, MALDI MS analysis requires little sample preparation, and in some cases like MS profiling it can be automated through the use of robotic liquid-handling systems. For more than a decade now, MALDI MS has been extensively utilised in the search for biomarkers that could aid clinicians in diagnosis, prognosis, and treatment decision making. This review examines the various MALDI-based MS techniques like MS imaging, MS profiling and proteomics in-depth analysis where MALDI MS follows fractionation and separation methods such as gel electrophoresis, and how these have contributed to prostate cancer biomarker research. This article is part of a Special Issue entitled: Biomarkers: A Proteomic Challenge.  相似文献   

2.
Serum protein profiling by MS is a promising method for early detection of disease. Important characteristics for serum protein profiling are preanalytical factors, analytical reproducibility and high throughput. Problems related to preanalytical factors can be overcome by using standardized and rigorous sample collection and sample handling protocols. The sensitivity of the MS analysis relies on the quality of the sample; consequently, the blood sample preparation step is crucial to obtain pure and concentrated samples and enrichment of the proteins and peptides of interest. This review focuses on the serum sample preparation step prior to protein profiling by MALDI MS analysis, with particular focus on various SPE methods. The application of SPE techniques with different chromatographic properties such as RP, ion exchange, or affinity binding to isolate specific subsets of molecules (subproteomes) is advantageous for increasing resolution and sensitivity in the subsequent MS analysis. In addition, several of the SPE sample preparation methods are simple and scalable and have proven easy to automate for higher reproducibility and throughput, which is important in a clinical proteomics setting.  相似文献   

3.
Proteomics profiling of intact proteins based on MALDI‐TOF MS and derived platforms has been used in cancer biomarker discovery studies. This approach suffers from a number of limitations such as low resolution, low sensitivity, and that no knowledge is available on the identity of the respective proteins in the discovery mode. Nevertheless, it remains the most high‐throughput, untargeted mode of clinical proteomics studies to date. Here we compare key protein separation and MS techniques available for protein biomarker identification in this type of studies and define reasons of uncertainty in protein peak identity. As a result of critical data analysis, we consider 3D protein separation and identification workflows as optimal procedures. Subsequently, we present a new protocol based on 3D LC‐MS/MS with top‐down at high resolution that enabled the identification of HNRNP A2/B1 intact peptide as correlating with the estrogen receptor expression in breast cancer tissues. Additional development of this general concept toward next generation, top‐down based protein profiling at high resolution is discussed.  相似文献   

4.
5.
Pools of O-glycopeptides prepared from trypsin-digested reduced and alkylated human serum IgA1 have been analyzed using matrix-assisted laser desorption ionization-time of flight-mass spectrometry (MALDI-ToF-MS) in the positive-ion mode, using 2,4,6-trihydroxy acetophenone-ammonium citrate matrix. Dozens of such pools prepared from normal serum IgA1 and from serum of patients with a number of different medical conditions have been routinely analyzed in this manner. The glycopeptides present in these pools possess identical amino acid sequences but are substituted with a variety of neutral and sialylated glycans and the spectra obtained were such that individual compositional glycoforms were baseline resolved. In addition, the spectra were reproducible, exhibiting a relative peak intensity and area variation of around 11-16%, enabling the technique to be used for the relative quantitation of the different compositional glycoforms present. This could be achieved manually or by applying a Java program especially developed for this purpose. The MS analysis described here is a major improvement over present MALDI methods used for profiling the O-glycosylation of IgA1. The MS methodology together with the Java data analysis are expected to be generally applicable for profiling O-linked glycopeptides derived from other glycoproteins and probably for N-linked glycopeptide pools.  相似文献   

6.
Sandflies (Diptera: Psychodidae) (Newstead, 1911) are blood‐feeding insects that transmit human pathogens including Leishmania (Trypanosomatida: Trypanosomatidae) parasites, causative agents of the leishmaniases. To elucidate Leishmania transmission cycles, conclusive identification of vector species is essential. Molecular approaches including matrix‐assisted laser desorption ionization time‐of‐flight mass spectrometry (MALDI‐TOF MS) protein profiling have recently emerged to complement morphological identification. The aim of this study was to evaluate the effect of the trap type used to collect sandflies, specifically Centers for Disease Control (CDC) light or sticky traps, the two most commonly used in sandfly surveys, on subsequent MALDI‐TOF MS protein profiling. Specimens of five species (Phlebotomus ariasi, Phlebotomus papatasi, Phlebotomus perniciosus, Phlebotomus sergenti, Sergentomyia minuta) collected in periurban and agricultural habitats in southeast Spain were subjected to protein profiling. Acquired protein spectra were queried against an in‐house reference database and their quality assessed to evaluate the trap type effect. The results indicate that trap choice can substantially affect the quality of protein spectra in collected sandflies. Whereas specimens retrieved from light traps produced intense and reproducible spectra that allowed reliable species determination, profiles of specimens from sticky traps were compromised and often did not enable correct identification. Sticky traps should therefore not be used in surveys that deploy MALDI‐TOF MS protein profiling for species identification.  相似文献   

7.
Protein profiling in blood serum by fractionation and MS analysis has been applied in mice to assess its applicability as a fast, economical alternative to current DNA and RNA analyses for diagnosis of neuromuscular disorders. Mass spectra of peptides and proteins were generated using serum from dystrophin-deficient mdx and control mice by WCX ClinProt bead fractionation, followed by MALDI-MS. Double cross-validatory linear discriminant and logistic regression data analysis methods were compared with a new Bayesian logistic regression method. These were evaluated on their ability to discriminate between healthy and dystrophic samples, and to identify the discriminatory peaks in the mass spectra. All three approaches classified the spectra with comparable misclassification rates (between 18.4 and 20.6%), with much overlap between the differential peaks identified between the methods. The differential peak pattern from the Bayesian method was sparser and easier to interpret than from the other two methods, without compromising classifying strength. One of the two main differentiating peaks at m/z 3908 was identified as an N-terminal peptide of coagulation Factor XIIIa, previously identified in human serum. This work underlines the translational aspect of serum protein profiling in mice and supports a further study with serum from patients with neuromuscular disorders.  相似文献   

8.
Hsieh SY  Chen RK  Pan YH  Lee HL 《Proteomics》2006,6(10):3189-3198
Blood is an ideal source for biomarker discovery. However, little has been done to address the effects of sampling, handling and storage procedures on serum/plasma proteomes. We used magnetic bead-based MALDI-TOF MS to systematically evaluate the influence of each procedure on low-molecular-weight serum/plasma proteome profiling on the basis of the whole spectra. We found that sampling procedures, including the selection of blood collection tubes and anticoagulants, variations in clotting time or time lag before centrifugation, and hemolysis, displayed significant effects on the proteomes. Moreover, serum and plasma were mutually incompatible for proteome comparison. By contrast, overnight fasting, handling procedures, including centrifugation speeds (1500 x g vs. 3000 x g) or time (15 min vs. 30 min), and storage conditions, such as at 4 degrees C or 25 degrees C for up to 24 h or at -80 degrees C for up to 3 months, and repeated freeze/thaw of up to ten cycles, had relatively minor effects on the proteomes based upon our analysis of about 100 peaks. We concluded that low-molecular-weight serum/plasma proteomes were diversely affected by sampling, handling and storage with most change from variations of sampling procedures. We therefore suggest the necessity of standardizing sampling procedure for proteome comparison and biomarker discovery.  相似文献   

9.
The peptide‐based quantitation accuracy and precision of LC‐ESI (QSTAR Elite) and LC‐MALDI (4800 MALDI TOF/TOF) were compared by analyzing identical Escherichia coli tryptic digests containing iTRAQ‐labeled peptides of defined abundances (1:1, 2.5:1, 5:1, and 10:1). Only 51.4% of QSTAR spectra were used for quantitation by ProteinPilot Software versus 66.7% of LC‐MALDI spectra. The average protein sequence coverages for LC‐ESI and LC‐MALDI were 24.0 and 18.2% (14.9 and 8.4 peptides per protein), respectively. The iTRAQ‐based expression ratios determined by ProteinPilot from the 57 467 ESI‐MS/MS and 26 085 MALDI‐MS/MS spectra were analyzed for measurement accuracy and reproducibility. When the relative abundances of peptides within a sample were increased from 1:1 to 10:1, the mean ratios calculated on both instruments differed by only 0.7–6.7% between platforms. In the 10:1 experiment, up to 64.7% of iTRAQ ratios from LC‐ESI MS/MS spectra failed S/N thresholds and were excluded from quantitation, while only 0.1% of the equivalent LC‐MALDI iTRAQ ratios were rejected. Re‐analysis of an archived LC‐MALDI sample set stored for 5 months generated 3715 MS/MS spectra for quantitation, compared with 3845 acquired originally, and the average ratios differed by only 3.1%. Overall, MS/MS‐based peptide quantitation performance of offline LC‐MALDI was comparable with on‐line LC‐ESI, which required threefold less time. However, offline LC‐MALDI allows the re‐analysis of archived HPLC‐separated samples.  相似文献   

10.
Flea identification is a significant issue because some species are considered as important vectors of several human pathogens that have emerged or re‐emerged recently, such as Bartonella henselae (Rhizobiales: Bartonellaceae) and Rickettsia felis (Rickettsiales: Rickettsiaceae). Matrix‐assisted laser desorption/ionization time‐of‐flight mass spectrometry (MALDI‐TOF MS) has been evaluated in recent years for the identification of multicellular organisms, including arthropods. A preliminary study corroborated the usefulness of this technique for the rapid identification of fleas, creating a preliminary database containing the spectra of five species of flea. However, longterm flea preservation in ethanol did not appear to be an adequate method of storage in the context of specimen identification by MALDI‐TOF MS profiling. The goal of the present work was to assess the performance of MALDI‐TOF MS in the identification of seven flea species [Ctenocephalides felis (Siphonaptera: Pulicidae), Ctenocephalides canis, Pulex irritans (Siphonaptera: Pulicidae), Archaeopsylla erinacei (Siphonaptera: Pulicidae), Leptopsylla taschenbergi (Siphonaptera: Ceratophyllidae), Stenoponia tripectinata (Siphonaptera: Stenoponiidae) and Nosopsyllus fasciatus (Siphonaptera: Ceratophyllidae)] collected in the field and stored in ethanol for different periods of time. The results confirmed that MALDI‐TOF MS can be used for the identification of wild fleas stored in ethanol. Furthermore, this technique was able to discriminate not only different flea genera, but also the two congeneric species C. felis and C. canis.  相似文献   

11.
The MALDI‐TOF MS has already been a main platform for phosphoproteome analysis. However, there are some weaknesses in direct analysis of endogenous phosphopeptides by MALDI‐TOF MS because of the serious suppression effect and poor ionization efficiency, which is brought by the excess of nonphosphopeptides and protein. It is essential to enrich endogenous phosphopeptides from complex biosamples efficiently prior to MALDI‐TOF MS analysis. Herein, we present a time‐saving and detailed protocol for the synthesis of titanium(iv)‐immobilized magnetic mesoporous silica nanoparticles (denoted as Fe3O4@mSiO2‐Ti4+), the subsequent enrichment process, and MALDI‐TOF MS analysis. We tested the LOD, size‐exclusive effect, reproducibility, and stability of Fe3O4@mSiO2‐Ti4+ nanoparticles. Furthermore, the ability of this protocol for identifying endogenous phosphopeptides in healthy human serum and saliva was investigated.  相似文献   

12.
We present here the results from MS peptide profiling experiments of prostate carcinoma patients and controls with a specific focus on protease activity‐related protein fragments. After purification with surface‐active magnetic beads, MALDI‐TOF profiling experiments were performed on tryptic digests of serum samples of prostate cancer patients with metastases (n=27) and controls (n=30). This resulted in the reproducible detection of eight differentially expressed peptides, which were then identified by nanoLC‐MALDI‐TOF/TOF and confirmed by MALDI‐FTMS exact mass measurements. All differentially expressed peptides are derived from two homologous parts of human serum albumin; two of the eight peptides were tryptic and six were nontryptic. The presence of the nontryptic fragments indicates that a proteolysis process occurs which is not mediated by trypsin. Since the nontryptic fragments were found at significantly higher levels in control samples compared with metastases samples, it is proposed that a specific proteolytic inhibition process is in effect in the serum of prostate cancer patients. Experiments using synthetic peptides showed that this proteolytic activity occurs ex vivo and is sequence specific. Importantly, the observed prostate carcinoma‐related inhibition of the proteolysis was reproduced ex vivo using synthetic peptides.  相似文献   

13.
The use of nLC-ESI-MS/MS in shotgun proteomics experiments and GeLC-MS/MS analysis is well accepted and routinely available in most proteomics laboratories. However, the same cannot be said for nLC-MALDI MS/MS, which has yet to experience such widespread acceptance, despite the fact that the MALDI technology offers several critical advantages over ESI. As an illustration, in an analysis of moderately complex sample of E. coli proteins, the use MALDI in addition to ESI in GeLC-MS/MS resulted in a 16% average increase in protein identifications, while with more complex samples the number of additional protein identifications increased by an average of 45%. The size of the unique peptides identified by MALDI was, on average, 25% larger than the unique peptides identified by ESI, and they were found to be slightly more hydrophilic. The insensitivity of MALDI to the presence of ionization suppression agents was shown to be a significant advantage, suggesting it be used as a complement to ESI when ion suppression is a possibility. Furthermore, the higher resolution of the TOF/TOF instrument improved the sensitivity, accuracy, and precision of the data over that obtained using only ESI-based iTRAQ experiments using a linear ion trap. Nevertheless, accurate data can be generated with either instrument. These results demonstrate that coupling nanoLC with both ESI and MALDI ionization interfaces improves proteome coverage, reduces the deleterious effects of ionization suppression agents, and improves quantitation, particularly in complex samples.  相似文献   

14.
Proteomic profiling by MALDI‐TOF MS presents various advantages (speed of analysis, ease of use, relatively low cost, sensitivity, tolerance against detergents and contaminants, and possibility of automation) and is being currently used in many applications (e.g. peptide/protein identification and quantification, biomarker discovery, and imaging MS). Earlier studies by many groups indicated that moderate reproducibility in relative peptide quantification is a major limitation of MALDI‐TOF MS. In the present work, we examined and demonstrate a clear effect, in cases apparently random, of sample dilution in complex samples (urine) on the relative quantification of peptides by MALDI‐TOF MS. Results indicate that in urine relative abundance of peptides cannot be assessed with confidence based on a single MALDI‐TOF MS spectrum. To account for this issue, we developed and propose a novel method of determining the relative abundance of peptides, taking into account that peptides have individual linear quantification ranges in relation to sample dilution. We developed an algorithm that calculates the range of dilutions at which each peptide responds in a linear manner and normalizes the received peptide intensity values accordingly. This concept was successfully applied to a set of urine samples from patients diagnosed with diabetes presenting normoalbuminuria (controls) and macroalbuminuria (cases).  相似文献   

15.
Lipopolysaccharide (LPS)-binding proteins interact with LPS in human serum and mediate various immune responses. We describe a high-throughput LPS-binding protein profiling platform for discovering unknown LPS-binding proteins and potential inflammatory mediators. As a pull-down method, the LPS molecules were immobilized onto epoxy beads and then directly incubated with human serum to screen LPS-binding proteins. Through the "untargeted" mass spectrometric approach, potential LPS-binding proteins which elicit various immune responses in human serum were identified by a highly sensitive LTQ Orbitrap Hybrid Fourier Transform Mass Spectrometer (LTQ Orbitrap FT MS). Therefore, this mass spectrometry (MS)-based profiling method is straightforward for screening unknown LPS-binding proteins and provides physiologically relevant binding partners in human serum.  相似文献   

16.
Matrix-assisted laser desorption ionization mass spectrometry (MALDI MS) has become a valuable tool to address a broad range of questions in many areas of biomedical research. One such application allows spectra to be obtained directly from intact tissues, termed "profiling" (low resolution) and "imaging" (high resolution). In light of the fact that MALDI tissue profiling allows over a thousand peptides and proteins to be rapidly detected from a variety of tissues, its application to disease processes is of special interest. For example, protein profiles from tumors may allow accurate prediction of tumor behavior, diagnosis, and prognosis and uncover etiologies underlying idiopathic diseases. MALDI MS, in conjunction with laser capture microdissection, is able to produce protein expression profiles from a relatively small number of cells from specific regions of heterogeneous tissue architectures. Imaging mass spectrometry enables the investigator to assess the spatial distribution of proteins, drugs, and their metabolites in intact tissues. This article provides an overview of several tissue profiling and imaging applications performed by MALDI MS, including sample preparation, matrix selection and application, histological staining prior to MALDI analysis, tissue profiling, imaging, and data analysis. Several applications represent direct translation of this technology to clinically relevant problems.  相似文献   

17.
Serum protein profiling by mass spectrometry is a promising method for early detection of cancer. We have implemented a combined strategy based on matrix-assisted laser desorption ionization mass spectrometry (MALDI MS) and statistical data analysis for serum protein profiling and applied it in a well-described breast cancer case-control study. A rigorous sample collection protocol ensured high quality specimen and reduced bias from preanalytical factors. Preoperative serum samples obtained from 48 breast cancer patients and 28 controls were used to generate MALDI MS protein profiles. A total of nine mass spectrometric protein profiles were obtained for each serum sample. A total of 533 common peaks were defined and represented a 'reference protein profile'. Among these 533 common peaks, we identified 72 peaks exhibiting statistically significant intensity differences ( p < 0.01) between cases and controls. A diagnostic rule based on these 72 mass values was constructed and exhibited a cross-validated sensitivity and specificity of approximately 85% for the detection of breast cancer. With this method, it was possible to distinguish early stage cancers from controls without major loss of sensitivity and specificity. We conclude that optimized serum sample handling and mass spectrometry data acquisition strategies in combination with statistical analysis provide a viable platform for serum protein profiling in cancer diagnosis.  相似文献   

18.
Mass spectrometry imaging and profiling of individual cells and subcellular structures provide unique analytical capabilities for biological and biomedical research, including determination of the biochemical heterogeneity of cellular populations and intracellular localization of pharmaceuticals. Two mass spectrometry technologies-secondary ion mass spectrometry (SIMS) and matrix assisted laser desorption/ionization mass spectrometry (MALDI MS)-are most often used in micro-bioanalytical investigations. Recent advances in ion probe technologies have increased the dynamic range and sensitivity of analyte detection by SIMS, allowing two- and three-dimensional localization of analytes in a variety of cells. SIMS operating in the mass spectrometry imaging (MSI) mode can routinely reach spatial resolutions at the submicron level; therefore, it is frequently used in studies of the chemical composition of subcellular structures. MALDI MS offers a large mass range and high sensitivity of analyte detection. It has been successfully applied in a variety of single-cell and organelle profiling studies. Innovative instrumentation such as scanning microprobe MALDI and mass microscope spectrometers enables new subcellular MSI measurements. Other approaches for MS-based chemical imaging and profiling include those based on near-field laser ablation and inductively-coupled plasma MS analysis, which offer complementary capabilities for subcellular chemical imaging and profiling.  相似文献   

19.
A group of coagulase negative staphylococcal strains isolated from indoor air of occupied school rooms were the subject of this study. Conventional MALDI TOF MS profiling of cellular extracts and physiological tests (including API STAPH) provided incomplete identification of the set of strains. After separation of a 100 kDa band using 1D gel electrophoresis, profiling of peptides (released with tryptic digestion) using MALDI TOF MS allowed improved bacterial speciation in addition to determination of the identity of the protein of origin (aconitate hydratase). This was performed by Mascot search, empirical observation and computer-generated cross-correlation analysis of environmental isolates versus reference strains. The species studied included some with sequenced genomes and others with un-sequenced genomes. Peptide sequences were confirmed to originate from aconitate hydratase using MALDI TOF-TOF MS-MS analysis of a diverse set of m/z values representing variable and conserved sequences. The methodological approach described here might have widespread application in speciation of environmental isolates of diverse origin and in identification of their expressed proteins.  相似文献   

20.
Blood represents a convenient diagnostic specimen for clinical analysis. Serum metabolites and peptides have the potential to serve as reliable indicators of progression from a normal to a diseased state. However, the presence of salts, lipids and high concentrations of protein in blood serum can adversely affect its mass spectrometric profiling, as all of these moieties can hinder the ionisation and detection of diagnostic biomarkers. Several pre-fractionation strategies using chromatographic adsorbents have been employed to desalt samples and remove abundant proteins such as albumin and immunoglobulin. As an alternative to multi-stage fractionation chromatography, we describe in this practical review the adaptation and validation of a simple and fast solid-phase extraction technique using ZipTips. The protocol allows for the purification and concentration of peptides in a few, mostly automated steps, prior to spectral biomarker pattern diagnostics using MALDI MS and MS/MS. It has the added advantages of being suitable for use in a high-throughput and potentially clinical environment, only requiring a few microlitres of serum. We have evaluated, optimised, and standardised a number of analytical parameters ranging from serum storage and handling to automated peptide extraction, crystallisation, spectral acquisition, and signal processing. Using standardised protocols the average CV of serum profiles within- and between-run replicates has been evaluated and found to be around 10 % based on the variability of all detected peaks (more than 100 peaks per profile). The results show that this easy and fast method of using ZipTips, tested over a whole year, is more reproducible and more suitable for serum profile screening than magnetic bead-based methodologies which show higher variability and higher rates of rejected, low-quality spectra upon applying strict data quality control filters.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号