首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Aortic valve (AV) calcification is a highly prevalent disease with serious impact on mortality and morbidity. Although exact causes and mechanisms of AV calcification are unclear, previous studies suggest that mechanical forces play a role. Since calcium deposits occur almost exclusively on the aortic surfaces of AV leaflets, it has been hypothesized that adverse patterns of fluid shear stress on the aortic surface of AV leaflets promote calcification. The current study characterizes AV leaflet aortic surface fluid shear stresses using Laser Doppler velocimetry and an in vitro pulsatile flow loop. The valve model used was a native porcine valve mounted on a suturing ring and preserved using 0.15% glutaraldehyde solution. This valve model was inserted in a mounting chamber with sinus geometries, which is made of clear acrylic to provide optical access for measurements. To understand the effects of hemodynamics on fluid shear stress, shear stress was measured across a range of conditions: varying stroke volumes at the same heart rate and varying heart rates at the same stroke volume. Systolic shear stress magnitude was found to be much higher than diastolic shear stress magnitude due to the stronger flow in the sinuses during systole, reaching up to 20 dyn/cm2 at mid-systole. Upon increasing stroke volume, fluid shear stresses increased due to stronger sinus fluid motion. Upon increasing heart rate, fluid shear stresses decreased due to reduced systolic duration that restricted the formation of strong sinus flow. Significant changes in the shear stress waveform were observed at 90 beats/min, most likely due to altered leaflet dynamics at this higher heart rate. Overall, this study represents the most well-resolved shear stress measurements to date across a range of conditions on the aortic side of the AV. The data presented can be used for further investigation to understand AV biological response to shear stresses.  相似文献   

2.
Aortic valve (AV) calcification is a highly prevalent disease with serious impact on mortality and morbidity. The exact cause and mechanism of the progression of AV calcification is unknown, although mechanical forces have been known to play a role. It is thus important to characterize the mechanical environment of the AV. In the current study, we establish a methodology of measuring shear stresses experienced by the aortic surface of the AV leaflets using an in vitro valve model and adapting the laser Doppler velocimetry (LDV) technique. The valve model was constructed from a fresh porcine aortic valve, which was trimmed and sutured onto a plastic stented ring, and inserted into an idealized three-lobed sinus acrylic chamber. Valve leaflet location was measured by obtaining the location of highest back-scattered LDV laser light intensity. The technique of performing LDV measurements near to biological surfaces as well as the leaflet locating technique was first validated in two phantom flow systems: (1) steady flow within a straight tube with AV leaflet adhered to the wall, and (2) steady flow within the actual valve model. Dynamic shear stresses were then obtained by applying the techniques on the valve model in a physiologic pulsatile flow loop. Results show that aortic surface shear stresses are low during early systole (<5 dyn/cm2) but elevated to its peak during mid to late systole at about 18-20 dyn/cm2. Low magnitude shear stress (<5 dyn/cm2) was observed during early diastole and dissipated to zero over the diastolic duration. Systolic shear stress was observed to elevate only with the formation of sinus vortex flow. The presented technique can also be used on other in vitro valve models such as congenitally geometrically malformed valves, or to investigate effects of hemodynamics on valve shear stress. Shear stress data can be used for further experiments investigating effects of fluid shear stress on valve biology, for conditioning tissue engineered AV, and to validate numerical simulations.  相似文献   

3.
The aortic valve (AV) achieves unidirectional blood flow between the left ventricle and the aorta. Although hemodynamic stresses have been shown to regulate valvular biology, the native wall shear stress (WSS) experienced by AV leaflets remains largely unknown. The objective of this study was to quantify computationally the macro-scale leaflet WSS environment using fluid–structure interaction modeling. An arbitrary Lagrangian–Eulerian approach was implemented to predict valvular flow and leaflet dynamics in a three-dimensional AV geometry subjected to physiologic transvalvular pressure. Local WSS characteristics were quantified in terms of temporal shear magnitude (TSM), oscillatory shear index (OSI) and temporal shear gradient (TSG). The dominant radial WSS predicted on the leaflets exhibited high amplitude and unidirectionality on the ventricularis (TSM>7.50 dyn/cm2, OSI < 0.17, TSG>325.54 dyn/cm2 s) but low amplitude and bidirectionality on the fibrosa (TSM < 2.73 dyn/cm2, OSI>0.38, TSG < 191.17 dyn/cm2 s). The radial WSS component computed in the leaflet base, belly and tip demonstrated strong regional variability (ventricularis TSM: 7.50–22.32 dyn/cm2, fibrosa TSM: 1.26–2.73 dyn/cm2). While the circumferential WSS exhibited similar spatially dependent magnitude (ventricularis TSM: 1.41–3.40 dyn/cm2, fibrosa TSM: 0.42–0.76 dyn/cm2) and side-specific amplitude (ventricularis TSG: 101.73–184.43 dyn/cm2 s, fibrosa TSG: 41.92–54.10 dyn/cm2 s), its temporal variations were consistently bidirectional (OSI>0.25). This study provides new insights into the role played by leaflet–blood flow interactions in valvular function and critical hemodynamic stress data for the assessment of the hemodynamic theory of AV disease.  相似文献   

4.
The bicuspid aortic valve (BAV) is a common congenital malformation of the aortic valve (AV) affecting 1% to 2% of the population. The BAV is predisposed to early degenerative calcification of valve leaflets, and BAV patients constitute 50% of AV stenosis patients. Although evidence shows that genetic defects can play a role in calcification of the BAV leaflets, we hypothesize that drastic changes in the mechanical environment of the BAV elicit pathological responses from the valve and might be concurrently responsible for early calcification. An in vitro model of the BAV was constructed by surgically manipulating a native trileaflet porcine AV. The BAV valve model and a trileaflet AV (TAV) model were tested in an in vitro pulsatile flow loop mimicking physiological hemodynamics. Laser Doppler velocimetry was used to make measurements of fluid shear stresses on the leaflet of the valve models using previously established methodologies. Furthermore, particle image velocimetry was used to visualize the flow fields downstream of the valves and in the sinuses. In the BAV model, flow near the leaflets and fluid shear stresses on the leaflets were much more unsteady than for the TAV model, most likely due to the moderate stenosis in the BAV and the skewed forward flow jet that collided with the aorta wall. This additional unsteadiness occurred during mid- to late-systole and was composed of cycle-to-cycle magnitude variability as well as high-frequency fluctuations about the mean shear stress. It has been demonstrated that the BAV geometry can lead to unsteady shear stresses under physiological flow and pressure conditions. Such altered shear stresses could play a role in accelerated calcification in BAVs.  相似文献   

5.
High levels of wall shear stress on the surface of valvular cusps can cause mechanical damage to the blood cells and the cusp surfaces. The shear stresses are also responsible for mechanical failure of prosthetic heart valves. Quatitative measurements of wall shear stress in the vicinity of the leaflets are thus essential for diagnosis of suspected complications and provide important information for the design and fabrication of bioprosthetic heart valves. For this purpose we measured the velocity distribution along the inside wall of the cusps of a tri-leaflet heart valve with a two colour laser Doppler anemometer system. The wall shear stresses on the cusp surface were computed and found to range from 80 to 120 N/m2 during the ejection phase. Wall shear stresses of up to 180 N/m2 were measured in loci of cusp flexure and the accelerated boundary layer. The results of this study show a correlation between the high shear stress loci and the clinically (animal) observed regions of cusp calcification.  相似文献   

6.
At present, little is known about how endothelial cells respond to spatial variations in fluid shear stress such as those that occur locally during embryonic development, at heart valve leaflets, and at sites of aneurysm formation. We built an impinging flow device that exposes endothelial cells to gradients of shear stress. Using this device, we investigated the response of microvascular endothelial cells to shear-stress gradients that ranged from 0 to a peak shear stress of 9–210 dyn/cm2. We observe that at high confluency, these cells migrate against the direction of fluid flow and concentrate in the region of maximum wall shear stress, whereas low-density microvascular endothelial cells that lack cell-cell contacts migrate in the flow direction. In addition, the cells align parallel to the flow at low wall shear stresses but orient perpendicularly to the flow direction above a critical threshold in local wall shear stress. Our observations suggest that endothelial cells are exquisitely sensitive to both magnitude and spatial gradients in wall shear stress. The impinging flow device provides a, to our knowledge, novel means to study endothelial cell migration and polarization in response to gradients in physical forces such as wall shear stress.  相似文献   

7.
At present, little is known about how endothelial cells respond to spatial variations in fluid shear stress such as those that occur locally during embryonic development, at heart valve leaflets, and at sites of aneurysm formation. We built an impinging flow device that exposes endothelial cells to gradients of shear stress. Using this device, we investigated the response of microvascular endothelial cells to shear-stress gradients that ranged from 0 to a peak shear stress of 9–210 dyn/cm2. We observe that at high confluency, these cells migrate against the direction of fluid flow and concentrate in the region of maximum wall shear stress, whereas low-density microvascular endothelial cells that lack cell-cell contacts migrate in the flow direction. In addition, the cells align parallel to the flow at low wall shear stresses but orient perpendicularly to the flow direction above a critical threshold in local wall shear stress. Our observations suggest that endothelial cells are exquisitely sensitive to both magnitude and spatial gradients in wall shear stress. The impinging flow device provides a, to our knowledge, novel means to study endothelial cell migration and polarization in response to gradients in physical forces such as wall shear stress.  相似文献   

8.
Since artificial heart valve related complications such as thrombus formation, hemolysis and calcification are considered related to flow disturbances caused by the inserted valve, a thorough hemodynamic characterization of heart valve prostheses is essential. In a pulsatile flow model, fluid velocities were measured one diameter downstream of a Hancock Porcine (HAPO) and a Ionescu-Shiley Pericardial Standard (ISPS) aortic valve. Hot-film anemometry (HFA) was used for velocity measurements at 41 points in the cross-sectional area of the ascending aorta. Three-dimensional visualization of the velocity profiles, at 100 different instants during one mean pump cycle, was performed. Turbulence analysis was performed as a function of time by calculating the axial turbulence energy within 50 ms overlapping time windows during the systole. The turbulent shear stresses were estimated by using the correlation equation between Reynolds normal stress and turbulent (Reynolds) shear stress. The turbulent shear stress distribution was visualized by two-dimensional color-mapping at different instants during one mean pump cycle. Based on the velocity profiles and the turbulent shear stress distribution, a relative blood damage index (RBDI) was calculated. It has the feature of combining the magnitude and exposure time of the estimated shear stresses in one index, covering the entire cross-sectional area. The HAPO valve showed a skewed jet-type velocity profile with the highest velocities towards the left posterior aortic wall. The ISPS valve revealed a more parabolic-shaped velocity profile during systole. The turbulent shear stresses were highest in areas of high or rapidly changing velocity gradients. For the HAPO valve the maximum estimated turbulent shear stress was 194 N m-2 and for the ISPS valve 154 Nm-2. The RBDI was the same for the two valves. The turbulent shear stresses had magnitudes and exposure times that might cause endothelial damage and sublethal or lethal damage to blood corpuscules. The RBDI makes comparison between different heart valves easier and may prove important when making correlation with clinical observations.  相似文献   

9.
The bicuspid aortic valve (BAV) is associated with a high prevalence of calcific aortic valve disease (CAVD). Although abnormal hemodynamics has been proposed as a potential pathogenic contributor, the native BAV hemodynamic stresses remain largely unknown. Fluid-structure interaction models were designed to quantify the regional BAV leaflet wall-shear stress over the course of CAVD. Systolic flow and leaflet dynamics were computed in two-dimensional tricuspid aortic valve (TAV) and type-1 BAV geometries with different degree of asymmetry (10 and 16% eccentricity) using an arbitrary Lagrangian–Eulerian approach. Valvular performance and regional leaflet wallshear stress were quantified in terms of valve effective orifice area (EOA), oscillatory shear index (OSI) and temporal shear magnitude (TSM). The dependence of those characteristics on the degree of leaflet calcification was also investigated. The models predicted an average reduction of 49% in BAV peak-systolic EOA relative to the TAV. Regardless of the anatomy, the leaflet wall-shear stress was side-specific and characterized by high magnitude and pulsatility on the ventricularis and low magnitude and oscillations on the fibrosa. While the TAV and non-coronary BAV leaflets shared similar shear stress characteristics, the base of the fused BAV leaflet fibrosa exhibited strong abnormalities, which were modulated by the degree of calcification (6-fold, 10-fold and 16-fold TSM increase in the normal, mildly and severely calcified BAV, respectively, relative to the normal TAV). This study reveals the existence of major differences in wall-shear stress pulsatility and magnitude on TAV and BAV leaflets. Given the ability of abnormal fluid shear stress to trigger valvular inflammation, the results support the existence of a mechano-etiology of CAVD in the BAV.  相似文献   

10.
Bone marrow mesenchymal stem cells (MSCs) have multi-differentiation capability. Their endothelial cell (EC) oriented differentiation is the key to vasculogenesis, in which both mechanical and chemical stimulations play important roles. Most previous studies reported individual effects of VEGF or fluid shear stress (SS), when MSCs were subjected to shear stress of 10–15 dyn/cm2 over 24 hr. In this paper, we investigated responses of MSCs from young Sprague Dawley rats to shear stress, VEGF and the combination of the two stimuli. Our study showed that the combined stimulation of shear stress and VEGF resulted in more profound EC oriented differentiation of MSCs in comparison to any individual stimulation. Furthermore, we subjected MSCs to prolonged period of fluid shear stimulation, i.e. 48 hr rather than 24 hr, and increased the magnitude of the shear stress from 10 dyn/cm2 to 15, 20 and 25 dyn/cm2. We found that without VEGF, the endothelium oriented differentiation of MSCs that was seen following 24 hr of shear stimulation was largely abolished if we extended the shear stimulation to 48 hr. A similar sharp decrease in MSC differentiation was also observed when the magnitude of the shear stress was increased from 10–15 dyn/cm2 to 20–25 dyn/cm2 in 24 hr shear stimulation studies. However, with combined VEGF and fluid shear stimulation, most of the endothelial differentiation was retained following an extended period, i.e. at 48 hr, of shear stimulation. Our study demonstrates that chemical and mechanical stimulations work together in determining MSC differentiation dynamics.  相似文献   

11.
BHK-21 cells were cultured under various shear stress conditions in an Integrated Rotating-Wall Vessel (IRWV). Shear ranged from 0.5 dyn/cm2 (simulated microgravity) to 0.92 dyn/cm2. Under simulated microgravity conditions, BHK-21 cells complexed into three-dimensional cellular aggregates attaining 6 × 106 cells/ml as compared to growth under 0.92 dyn cm2 conditions. Glucose utilization in simulated microgravity was reduced significantly, and cellular damage at the microcarrier surface was kept to a minimum. Thus, the integrated rotating wall vessel provides a quiescent environment for the culture of mammalian cells. © 1993 Wiley-Liss, Inc.  相似文献   

12.
Summary As mostin vitro endothelial cell (EC)-vascular smooth muscle cell (SMC) co-culture studies have been performed utilizing static culture conditions, none have successfully mimicked the physical environment of these cellsin vivo. EC covering the inner surface of blood vessels are continuously exposed to a hemodynamically imposed mechanical stress resulting from the flow of blood, while SMC are affected by pressure, a flow-related force acting perpendicular to the surface. We have developed a perfused transcapillary co-culture system that permits the chronic exposure of EC and SMC to physiological shear stresses and pressures. SMC and EC co-cultures were successfully established and maintained in long-term culture (7 wk) on an enclosed perfused bundle of semipermeable polypropylene capillaries. By altering flow rate and/or viscosity, shear stresses of 0.07–20 dyn/cm2 can be readily achieved in this system. Electron microscopic analysis revealed that SMC formed multilayers around the outside of the capillaries, whereas EC, subjected to 3 dyn/cm2 shear stress, formed an intact closely adherent monolayer lining the capillary lumen. EC and SMC exhibited characteristic ultrastructural and gross morphology. EC were separated from SMC by the capillary wall (pore size 0.5 μm, width 150 μM) and while no direct cell-cell contact was evident some cells were seen to migrate into the capillary wall. Both EC and SMC are exposed to the same culture medium, allowing the interaction of substances released in both directions. Yet separate populations of cells are maintained and can be individually harvested for further analysis. This co-culture system that mimics the architecture and physical environment of the vessel wall should have many potential applications in vascular biology.  相似文献   

13.

Aims

Oxidative stress is present in and contributes to calcification of the aortic valve, but the driving factors behind the initiation of valve oxidative stress are not well understood. We tested whether the valve endothelium acts as an initiator and propagator of oxidative stress in aortic valve disease.

Methods and Results

Calcified human aortic valves showed side-specific elevation of superoxide in the endothelium, co-localized with high VCAM1 expression, linking oxidative stress, inflammation, and valve degeneration. Treatment with inflammatory cytokine TNFα increased superoxide and oxidative stress and decreased eNOS and VE-cadherin acutely over 48 hours in aortic valve endothelial cells (VEC) and chronically over 21 days in ex vivo AV leaflets. Co-treatment of VEC with tetrahydrobiopterin (BH4) but not apocynin mitigated TNFα-driven VEC oxidative stress. Co-treatment of ex vivo AV leaflets with TNFα+BH4 or TNFα+peg-SOD rescued endothelial function and mitigated inflammatory responses. Both BH4 and peg-SOD rescued valve leaflets from the pro-osteogenic effects of TNFα treatment, but only peg-SOD was able to mitigate the fibrogenic effects, including increased collagen and αSMA expression.

Conclusions

Aortic valve endothelial cells are a novel source of oxidative stress in aortic valve disease. TNFα-driven VEC oxidative stress causes loss of endothelial protective function, chronic inflammation, and fibrogenic and osteogenic activation, mitigated differentially by BH4 and peg-SOD. These mechanisms identify new targets for tailored antioxidant therapy focused on mitigation of oxidative stress and restoration of endothelial protection.  相似文献   

14.
Endothelial cells lining blood vessels are exposed to various hemodynamic forces associated with blood flow. These include fluid shear, the tangential force derived from the friction of blood flowing across the luminal cell surface, tensile stress due to deformation of the vessel wall by transvascular flow, and normal stress caused by the hydrodynamic pressure differential across the vessel wall. While it is well known that these fluid forces induce changes in endothelial morphology, cytoskeletal remodeling, and altered gene expression, the effect of flow on endothelial organization within the context of the tumor microenvironment is largely unknown. Using a previously established microfluidic tumor vascular model, the objective of this study was to investigate the effect of normal (4 dyn/cm2), low (1 dyn/cm2), and high (10 dyn/cm2) microvascular wall shear stress (WSS) on tumor-endothelial paracrine signaling associated with angiogenesis. It is hypothesized that high WSS will alter the endothelial phenotype such that vascular permeability and tumor-expressed angiogenic factors are reduced. Results demonstrate that endothelial permeability decreases as a function of increasing WSS, while co-culture with tumor cells increases permeability relative to mono-cultures. This response is likely due to shear stress-mediated endothelial cell alignment and tumor-VEGF-induced permeability. In addition, gene expression analysis revealed that high WSS (10 dyn/cm2) significantly down-regulates tumor-expressed MMP9, HIF1, VEGFA, ANG1, and ANG2, all of which are important factors implicated in tumor angiogenesis. This result was not observed in tumor mono-cultures or static conditioned media experiments, suggesting a flow-mediated paracrine signaling mechanism exists with surrounding tumor cells that elicits a change in expression of angiogenic factors. Findings from this work have significant implications regarding low blood velocities commonly seen in the tumor vasculature, suggesting high shear stress-regulation of angiogenic activity is lacking in many vessels, thereby driving tumor angiogenesis.  相似文献   

15.
为探讨流体剪切力对内皮细胞micorRNAs表达的影响。采用旋转锥形圆盘剪切力系统对内皮细胞分别加载低(4dyn/cm2)、中(10 dyn/cm2)和高(15 dyn/cm2)3种不同梯度的剪切力作用24h。对照组未加载剪切力。采用高通量筛选芯片检测microRNAs表达变化,qRT-PCR验证,并进行生物信息学分析。与对照组比较,低剪切力组表达差异的microRNAs有33个(FC1.5或0.5倍,P0.05),其中28个上调,5个下调;中剪切力组表达差异的microRNAs有8个(FC1.5或0.5倍,P0.05),其中6个上调,2个下调;高剪切力组表达差异的microRNAs有31个(FC1.5或0.5倍,P0.05),其中25个上调,6个下调。miR-21在高剪切力组中上调最显著(FC=0.026),在低剪切力组中显著下调(FC=3.531)。miR-199a在低剪切力组中上调最显著(FC=0.075),在高剪切力组中显著下调(FC=3.031)。表达差异的microRNA的靶基因主要与内皮细胞的力学信号转导、细胞跨膜迁移、钙离子信号通路、细胞内吞作用等相关。流体剪切力可诱导内皮细胞miR-21和miR-199a表达发生改变。  相似文献   

16.
Fluid shear stress has been known to activate platelet reaction such as aggregation, but the exact mechanism of shear-induced platelet aggregation (SIPA) has not been fully understood. Calpain, an intracellular calcium-activated cysteine protease, is abundant in platelets and is considered to be activated and involved in the proteolytic processes during platelet activation. A possible activation of calpain in SIPA was investigated, employing a newly developed aggregometer and specific monoclonal antibodies to detect activation of calpain. When a shear stress gradient varying between 6 and 108 dyn/cm2 was applied to platelets, activation of μ-calpain was observed only in high-shear-stressed platelets, resulting in the proteolysis of talin. At 1 min after the onset of constant high shear stress of 108 dyn/cm2, μ-calpain activation and proteolysis of talin were detected and increased in a time-dependent manner. Constant shear stress more than 50 dyn/cm2, applied for 5 min, caused μ-calpain activation and proteolysis of talin, which were increased in a shear-force-dependent manner. Calpeptin, a calpain-specific peptide antagonist, caused the complete inhibition of both μ-calpain activation and proteolysis of talin, while SIPA profiles with calpeptin showed almost no change compared to those without calpeptin. These results suggest the possibility of calpain involvement in late phases of shear-induced platelet activation such as cytoskeletal reorganization. J. Cell. Biochem. 66:54–64, 1997. © 1997 Wiley-Liss, Inc.  相似文献   

17.
The shear stress at the wall has been of interest as one of the possible fluid dynamic factors that may be damaging in the region of prosthetic valves. The purpose of this study was to measure the axial wall shear stresses in the region of a 29 mm tissue annulus diameter porcine stent mounted prosthetic aortic valve (Hancock, Model 242). Studies were performed in an in vitro pulse duplicating system. The axial wall shear stress was calculated from velocities obtained near the wall with a laser Doppler anemometer. The largest axial wall shear stress was 29 dyn cm-2 and it occurred at the highest stroke volume used (80 ml). At a stroke volume of 50 ml, the largest axial wall shear stress was 17 dyn cm-2 and at a stroke volume of 35 ml, it was 15 dyn cm-2. Stresses of these magnitudes are far below those reported to be damaging to the endothelial surface. These stresses may be high enough, however, to affect platelet function.  相似文献   

18.
Red cells which adhere to a surface in a parallel plate flow channel are stretched when acted on by a fluid shear stress. Three types of stretching are studied: whole cell stretching, the stretching of a red cell evagination, and tether (long, thin membrane process) stretching. In addition, the stretching of a large scale model cell attached to a surface is studied in a Couette flow channel. The results indicate that the uniaxial stretching of red cell membrane can be described by a linear stress-strain relationship. Simple theories developed from free body diagrams permit the calculation of a value for the modulus of elasticity of cell membrane in each of the three experiments. In all cases the value for the modulus is on the order of 104 dyn/cm2 for an assumed membrane thickness of 0.01 μm. It was also observed that red cell tethers steadily increase in length when the fluid shear stress is greater than approximately 1.5 dyn/cm2 and tether lengths in excess of 200 μm have been achieved. Tethers appear to possess both fluid and elastic properties.  相似文献   

19.
The effect of collagen fibers on the mechanics and hemodynamics of a trileaflet aortic valve contained in a rigid aortic root is investigated in a numerical analysis of the systolic phase. Collagen fibers are known to reduce stresses in the leaflets during diastole, but their role during systole has not been investigated in detail yet. It is demonstrated that also during systole these fibers substantially reduce stresses in the leaflets and provide smoother opening and closing. Compared to isotropic leaflets, collagen reinforcement reduces the fluttering motion of the leaflets. Due to the exponential stress-strain behavior of collagen, the fibers have little influence on the initial phase of the valve opening, which occurs at low strains, and therefore have little impact on the transvalvular pressure drop.  相似文献   

20.
In this paper, a finite element analysis of the stress distribution on the cusps of a polyurethane trileaflet heart valve prosthesis in the closed position is presented. The geometry of the valve was modified from a relationship proposed by Ghista and Reul (J. Biomechanics 10, 313-324, 1977). The effects of variations in stent height, leaflet thickness and coaptation area on the stress distribution were also analyzed. Analyses were performed with both rigid and flexible stents for the trileaflet valve in order to delineate the effect of stent flexibility on the leaflet stress distribution. The results showed that regions of stress concentration were present near the commissural attachment similar to those predicted with the bioprostheses. The stresses on the leaflets were reduced by increasing the stent height with both rigid and flexible stents. Selectively increasing the leaflet thickness near the commissures and also increasing the coaptation area did not prove to reduce the leaflet stresses when the stent flexibility was taken into account. The possible effect of high stresses on the structural integrity of polyurethane leaflets and its relationship with calcification is yet to be investigated.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号