首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 906 毫秒
1.
The pressure induced structural and mechanical properties of nanocrystalline ZnO, ZnS, ZnSe, GaN, CoO, CdSe, CeO(2), SnO(2), SiC, c-BC(2)N, and β-Ga(2)O(3) with different grain sizes have been analyzed under high pressures. The molecular dynamics simulation model has been used to compute isothermal equation of state, volume collapse and bulk modulus of these materials in nano and bulk phases at ambient and high pressures and compared with the experimental data. It is evident from these calculations that the change in particle size affects directly the phase transition pressure and bulk modulus. The values of phase transition pressure and bulk modulus increase with decrease in grain size of the material. The equilibrium cell volume and volume collapse in parent phase is directly proportional to the grain size of the materials. Present results are in good agreement with experimental data. The model is able to explain these thermodynamic properties at varying temperatures and pressures successfully.  相似文献   

2.
The maximum pore fluid pressures due to uniaxial compression are determined for both the vascular porosity (Haversian and Volkmann's canals) and the lacunar-canalicular porosity of live cortical bone. It is estimated that the peak pore water pressure will be 19 percent of the applied axial stress in the vascular porosity and 12 percent of the applied axial stress in the lacunar-canalicular porosity for an impulsive step loading. However, the estimated relaxation time for the vascular porosity (1.36 microseconds) is three orders of magnitude faster than that estimated for the lacunar-canalicular porosity (4.9 ms). Thus, under physiological loading, which has a stress rise time generally larger than 1 ms, pressures higher than the vascular pressure cannot be sustained in the vascular porosity due to the swift pressure relaxation in this porosity (unless the fluid drainage through the boundary is obstructed). The model also predicts a slight hydraulic stiffening of the bulk modulus due to longer draining time of the lacunar-canalicular porosity. The undrained bulk modulus is 6 percent higher than the drained bulk modulus in this case.  相似文献   

3.
Blast waves generated by improvised explosive devices can cause mild, moderate to severe traumatic brain injury in soldiers and civilians. To understand the interactions of blast waves on the head and brain and to identify the mechanisms of injury, compression-driven air shock tubes are extensively used in laboratory settings to simulate the field conditions. The overall goal of this effort is to understand the mechanics of blast wave–head interactions as the blast wave traverses the head/brain continuum. Toward this goal, surrogate head model is subjected to well-controlled blast wave profile in the shock tube environment, and the results are analyzed using combined experimental and numerical approaches. The validated numerical models are then used to investigate the spatiotemporal distribution of stresses and pressure in the human skull and brain. By detailing the results from a series of careful experiments and numerical simulations, this paper demonstrates that: (1) Geometry of the head governs the flow dynamics around the head which in turn determines the net mechanical load on the head. (2) Biomechanical loading of the brain is governed by direct wave transmission, structural deformations, and wave reflections from tissue–material interfaces. (3) Deformation and stress analysis of the skull and brain show that skull flexure and tissue cavitation are possible mechanisms of blast-induced traumatic brain injury.  相似文献   

4.
A collapsible tube surrounded by soft material within a rigid box was proposed as a two-dimensional mechanical model for the pharyngeal airway. This model predicts that changes in the box size (pharyngeal bony enclosure size anatomically defined as cross-sectional area bounded by the inside edge of bony structures such as the mandible, maxilla, and spine, and being perpendicular to the airway) influence patency of the tube. We examined whether changes in the bony enclosure size either with head positioning or bite opening influence collapsibility of the pharyngeal airway. Static mechanical properties of the passive pharynx were evaluated in anesthetized, paralyzed patients with sleep-disordered breathing before and during neck extension with bite closure (n = 11), neck flexion with bite closure (n = 9), and neutral neck position with bite opening (n = 11). Neck extension significantly increased maximum oropharyngeal airway size and decreased closing pressures of the velopharynx and oropharynx. Notably, neck extension significantly decreased compliance of the oropharyngeal airway wall. Neck flexion and bite opening decreased maximum oropharyngeal airway size and increased closing pressure of the velopharynx and oropharynx. Our results indicate the importance of neck and mandibular position for determining patency and collapsibility of the passive pharynx.  相似文献   

5.
The purpose of this study was to determine the true intraocular pressure and modulus of elasticity of the human cornea in vivo. The cornea was modeled as a shell, and the equations for the deformations of a shell due to applanating and intraocular pressures were combined to model the behavior of the cornea during applanation tonometry. At certain corneal dimensions called the calibration dimensions, the applanating and intraocular pressures are considered to be equal. This relationship was used to determine the modulus of elasticity of the cornea and the relationship between the applanating and intraocular pressures. The true intraocular pressure (IOPT) was found to be related to Goldmann’s applanating pressure (IOPG) as (IOPT = IOPG/K, where K is a correction factor. For the calibration corneal thickness of 0.52 mm, the modulus of elasticity E in MPa of the human cornea was found to be related to the true intraocular pressure IOPT in mmHg as E = 0.0229IOPT. The generalization of the Imbert—Fick law that takes into account the effect of corneal dimensions and stiffness was found to be given by IOPT = 73.5W/(K A), where W is the applanating weight in gf (gram force) and A is the applanated area in mm2. The calculated true intraocular pressure and modulus of elasticity were found to agree with published experimental results. The mathematical model developed may therefore be used to improve results from applanation tonometry and to estimate the mechanical property of the cornea in vivo.  相似文献   

6.
Prediction of femoral head collapse in osteonecrosis   总被引:6,自引:0,他引:6  
The femoral head deteriorates in osteonecrosis. As a consequence of that, the cortical shell of the femoral head can buckle into the cancellous bone supporting it. In order to examine the buckling scenario we performed numerical analysis of a realistic femoral head model. The analysis included a solution of the hip contact problem, which provided the contact pressure distribution, and subsequent buckling simulation based on the given contact pressure. The contact problem was solved iteratively by approximating the cartilage by a discrete set of unilateral linear springs. The buckling calculations were based on a finite element mesh with brick elements for the cancellous bone and shell elements for the cortical shell. Results of 144 simulations for a variety of geometrical, material, and loading parameters strengthen the buckling scenario. They, particularly, show that the normal cancellous bone serves as a strong supporting foundation for the cortical shell and prevents it from buckling. However, under the development of osteonecrosis the deteriorating cancellous bone is unable to prevent the cortical shell from buckling and the critical pressure decreases with the decreasing Young modulus of the cancellous bone. The local buckling of the cortical shell seems to be the driving force of the progressive fracturing of the femoral head leading to its entire collapse. The buckling analysis provides an additional criterion of the femoral head collapse, the critical contact pressure. The buckling scenario also suggests a new argument in speculating on the femoral head reinforcement. If the entire collapse of the femoral head starts with the buckling of the cortical shell then it is reasonable to place the reinforcement as close to the cortical shell as possible.  相似文献   

7.
The reflection of pressure waves in a fluid enclosed within a tube with an elastic wall is studied for the case of a localized change in diameter of the tube. The concept of impedance is introduced. The relation of the reflection characteristics of the parts of the tube at either side of the change is derived on the basis of the continuity of pressure and mass flow at the site of the change. This relations is used to derive the expression for the ratio of the pressure oscillations measured in front of, and behind, the constriction in terms of the constants of the system. As a result, a method is indicated to locate the coarctation from measurements of the pressures in front of, and behind it.  相似文献   

8.
Zhao J  Lu X  Zhuang F  Gregersen H 《Biorheology》2000,37(5-6):385-400
Morphometric and passive biomechanical properties were studied in isolated segments of the thoracic and abdominal aorta, left common carotid artery, left femoral artery and the left pulmonary artery in 20 non-diabetic and 28 streptozotocin (STZ)-induced diabetic rats. The diabetic and non-diabetic rats were divided into groups living 1, 4, 8, and 12 weeks after the induction of diabetes (n = 7 for each diabetic group) or sham injection (n = 5 for each group). The mechanical test was performed as a distension experiment where the proximal end of the arterial segment was connected via a tube to the container used for applying pressures to the segment and the distal end was left free. The vessel diameter and length were obtained from digitized images of the arterial segments at pre-selected pressures and at no-load and zero-stress states. Circumferential and longitudinal stresses (force per area) and strains (deformation) were computed from the length, diameter and pressure data and from the zero-stress state data. The zero-stress state was obtained by cutting vessel rings radially causing the rings to open up into a sector. Diabetes was associated with pronounced morphometric changes, e.g., wall thickness. With respect to the biomechanical data, the opening angle increased and reached a plateau in 4 weeks after which it decreased again (p < 0.05). The opening angle was smallest in the thoracic aorta and largest in the pulmonary artery. Furthermore, it was found that the circumferential stiffness of the arteries studied increased with the duration of diabetes. In the longitudinal direction significant differences were found 8 weeks after injection of STZ in all arteries except the pulmonary artery. In the 12 weeks group, the femoral artery was stiffest in the circumferential direction whereas the thoracic aorta was stiffest in the longitudinal direction. The accumulated serum glucose level correlated with the arterial wall thickness and elastic modulus (correlation coefficient between 0.56 and 0.81).  相似文献   

9.
The turtle shell is an amazing structure optimized through the long-term evolution by nature.This paper reports the mechanical response of the shell (Red-ear turtle) to static and dynamic loads,respectively.It is found that the turtle shell under a compressive load yields the maximum vertical displacement at the rear end,but the vertical displacement at the front end is only half of that at the rear end.The maximum horizontal displacement of the shell also occurs at the rear end.It is believed that such a deformation pattern is helpful for protecting the turtle's internal organs and its head.The principal stress directions in the inside surface of the shell under a compressive load are almost the same as those of the biofiber distribution in the inside surface,which results in the strong bending resistance of the turtle shell.  相似文献   

10.
Measurement of turgor pressure and its gradient in the Phloem of oak   总被引:12,自引:11,他引:1       下载免费PDF全文
Hammel HT 《Plant physiology》1968,43(7):1042-1048
A direct method is described for measuring the pressure in secondary phloem sieve tubes of oak trees. One end of a 26-gauge stainless steel tube was shaped such that when it penetrated the outer bark and transected a few sieve elements, it was stopped by the xylem so that small openings in the end allowed phloem sap to enter the tube. The other end of the stainless tube (phloem needle) was joined to a long glass capillary sealed at its other end to form a manometer for measuring phloem sap pressure. A method for measuring the average osmotic and turgor pressures in cells of leaves is also described. Phloem turgor pressures varied greatly in a series of phloem punctures around the trunk at 1.5 and at 6.3 meters. The variation in turgor pressure was always greater than the variation in osmotic pressure. In a series of turgor pressures arranged in descending order, the values in a sequence for the upper level was usually a little (0-3 atm) larger than the values for the lower level. These results may suggest that translocation of assimilate is favored by a small turgor pressure gradient, but they do more to emphasize the complications in measuring gradients in an elastic low resistance distribution system composed of contiguous longitudinal conduits. The results also imply that the sieve tubes are inflated with assimilate fluid under high pressure which can readily move longitudinally and with less pressure drop than would be necessary if the sieve tubes were rigid.  相似文献   

11.
Water penetration in the low and high pressure native states of ubiquitin   总被引:1,自引:0,他引:1  
Day R  García AE 《Proteins》2008,70(4):1175-1184
Theoretical studies on the solvation of methane molecules in water have shown that the effect of increased pressure is to stabilize solvent separated contacts relative to direct contacts. This suggests that high pressure stabilizes waters that have penetrated into a protein's core, indicating a mechanism for the high pressure denaturation of proteins. We test this theory on a folded protein by studying the penetration of water into the native state of ubiquitin at low and high pressures, using molecular dynamics. An ensemble of conformations sampled in the folded state of ubiquitin has been determined by NMR at two pressures below the protein's denaturation pressure, 30 atm and 3000 atm. We find that 1-5 more waters penetrate the high pressure conformations than the low pressure conformations. Low volume configurations of the system are favored at high pressures, but different components of the system may experience increases or decreases in their specific volumes. We find that penetrating waters have a higher volume per water than bulk waters, but that the volume per protein residue may be lowered by solvation. Furthermore, we find that penetration of the protein by water at high pressures is driven by the difference in the pressure dependence of the probability of cavity opening in the protein and pressure dependence of the probability of cavity opening in the bulk solvent. The volume changes associated with cavity opening and closing indicate that each penetrating water reduces the volume of the system by about 12 mL/mol. The experimental volume change going from the low pressure to the high pressure native state of ubiquitin is 24 mL/mol. Our results indicate that this volume change can be explained by penetration of the protein by two water molecules.  相似文献   

12.
Middle ear barotrauma during flight is a painful disorder experienced by passengers who cannot properly regulate their middle ear pressure in response to the changing cabin pressures during ascent and descent. Previous reports emphasized the important role of poor eustachian tube function in disease pathogenesis but paid little attention to other moderating factors. Here we describe a mathematical model of middle ear pressure regulation and simulate the pressure response to the changes in cabin pressure experienced over typical flights. The results document buffering mechanisms that decrease the requisite efficiency of active, muscle-assisted eustachian tube opening for disease-free flight. These include the relative difference between destination and departure elevations and the ratio of maximum tympanic membrane volume displacement to middle ear volume, where greater absolute values require lesser efficiencies for disease-free flight. Also, the specific type of functional deficit is important since ears with a completely obstructed eustachian tube can be less susceptible to barotrauma than those with a eustachian tube that passively opens but fails to dilate in response to muscle activity. These buffering systems can explain why some children and adults with poor eustachian tube function do not experience middle ear barotrauma.  相似文献   

13.
The work is devoted to the registration and the study of the properties of cylindrical shock waves generated in the fast discharge (dI/dt ~ 1012 A/s) inside the ceramic tube (Al2O3) filled by argon at pressures of 100 and 300 Pa. The shock wave appears at the inner wall of the insulator and moves to the discharge axis with a velocity of about (3?4) × 106 cm/s with subsequent cumulation. The plasma behind the front is heated enough to produce radiation in the vacuum ultraviolet (VUV) region, which makes it possible to study its structure by means of a pinhole camera with a microchannel plate detector. The time resolution of the registration system was 10 ns. The analysis of VUV spectra of the plasma shows that the electron temperature behind the shock wave front is about several eV; after the moment of cumulation, its temperature increases to 20–30 eV.  相似文献   

14.
Finite element stress analyses were conducted of the canine femoral head before and after implantation of various surface replacement-type components. The femoral head was replaced by four implant geometries; (a) shell, (b) shell with peg, (c) shell with rod, and (d) a new epiphyseal replacement design. All implants were modelled to simulate bony ingrowth along the underside of the shell and along the surfaces of the peg and rod. The results indicated that in the normal femur the forces are transferred from the articular surface through the femoral head cancellous bone to the inferior cortical shell of the femoral neck. After shell-type surface replacement, forces were transferred more distally at the rim of the shell and at the end of the peg or rod, thereby reducing the stresses in the proximal head cancellous bone. Computer simulation of bone remodelling due to proximal bone stress reduction was shown to accentuate the abnormality of the stress fields. Surface replacement with a lower modulus material created a less abnormal redistribution of bone stresses. The new epiphyseal replacement design resulted in stress distributions similar to those in the normal femoral head and minimal shear stresses at the implant/bone interface. These findings suggest that the epiphyseal replacement concept may provide better initial mechanical integrity and create a more benign milieu for adaptive bone remodelling than conventional, shell-type surface replacement components.  相似文献   

15.
P L Lane  B A McLellan  P D Johns 《CMAJ》1985,133(3):199-201
Patients who have suffered blunt trauma and present in shock of uncertain cause represent a problem frequently encountered by emergency physicians. A retrospective review of the charts of 879 patients who had suffered blunt trauma and presented to a regional trauma unit over a 44-month period revealed that 154 of the patients had presented to either a hospital or the trauma unit in shock. The most common causes of shock when a single source of hemorrhage was identified were, in order of decreasing frequency, intraperitoneal hemorrhage, pelvic or other musculoskeletal fractures, thoracic hemorrhage, severe head injury and spinal cord injury. Severe head injuries accounted for only 8% of the single-source cases and contributed to shock in only seven of the remaining cases.  相似文献   

16.
A working model of a sieve tube is described, based upon thePressure-Flow Hypothesis. The flow of solution in the sievetube is envisaged as being due to the joint influence of anaxial turgor pressure gradient and a lateral water potentialdifference which causes an intake of water along the tube. Inthis second respect the model differs from that originally suggestedby Münch. The model comprises a length of dialysis tubing rendered semi-permeable,incorporating capillary resistances at regular intervals. Asucrose solution is pumped into one end and collected at theother, the whole being submerged in water. Turgor pressures and concentrations along the model were recordedat intervals; thus the approach to the steady state was followed.In the steady state 14C-sucrose was introduced to the solutionbeing pumped and its approach to a steady distribution in themodel was followed. Important conclusions reached are that the Munch Pressure-FlowHypothesis implies a pressure profile convex upwards, a velocityincrease down the phloem, and an exponential fall in tracerconcentration without its lateral leakage.  相似文献   

17.
Ultrasonography of the optic nerve sheath diameter (ONSD) is a non-invasive and rapid method that might be helpful in the identification of increased intracranial pressure (ICP). The use of an ONSD greater than 5 mm on ultrasound as an indicator of increased ICP in a Caucasian population has been studied. However, the cut-off point of this predictor in Chinese patients has not been established. Thus, we conducted this study to identify the ONSD criterion for the detection of elevated opening pressure on lumbar puncture (LP) in a Chinese population and to investigate the influencing factors. This study was a blind cross-sectional study. Patients who presented with suspected increased ICP were included. The opening pressure on LP of each participant was confirmed. We analyzed the clinical differences between the groups of patients with abnormal and normal opening pressures on LP. A receiver operating characteristic curve was constructed to determine the ONSD cut-off point for the identification of abnormal opening pressure on LP. In total, 279 patients were recruited, and 101 patients presented with elevated opening pressure on LP. ONSD was a significant independent predictor of elevated opening pressure on LP (p<0.001). However, no statistical significance was observed regarding the factors that might have affected this relationship including gender, age, body mass index, waistline, head circumference, hypertension and pathological subtype. The ONSD cut-off point for the identification of elevated opening pressure on LP was 4.1 mm; this cut-off yielded a sensitivity of 95% and a specificity of 92%. ONSD is a strong and accurate predictor of elevated opening pressure on LP. The cut-off point of this predictor in a Chinese population was remarkably lower than that found in a Caucasian population. Thus, ethnic differences should be noted when using the ONSD as an indicator of increased ICP.  相似文献   

18.
We report our experience with an ultrasound system to measure esophageal varix pressure in an in vitro model. The ultrasound system consists of a 12.5 MHz frequency intraluminal ultrasound probe, a water infusion catheter, and a manometry catheter, all contained within a nondistensible latex bag. Esophagi and external jugular veins were harvested from five pigs. The vein and ultrasound system were placed inside the esophagus. One end of the vein was connected to a water reservoir to modulate its pressure; the other end was connected in two different ways to simulate hydrodynamic and hydrostatic flow conditions. The bag was inflated with water until vein occlusion was discernible on the ultrasound images. The influences of vein pressure, vein cross-sectional area and esophageal elasticity on the ultrasound measurement of vein pressure were assessed. A total of 108 trials were performed at nine different vein pressures. Complete vein occlusion occurred when the bag pressure was slightly greater (1.4 +/- 0.7 mmHg) than the vein pressure. For a vein pressure of 25 mmHg, the average occlusion and opening pressures were 27 +/- 0.2 and 25.7 +/- 0.3 mmHg, respectively (P < .05) suggesting that the vein opening pressure on the ultrasound images is more accurate than the vein closing pressure. In conclusion, the ultrasound technique can accurately measure intravariceal pressure in vitro. The bag pressure at the point of vein reopening is the best determinant of the vein pressure.  相似文献   

19.
Changes in respiratory mechanical loads are readily detected by humans. Although it is widely believed that respiratory muscle afferents serve as the primary source of information for load detection, there is, in fact, no convincing evidence to support this belief. We developed a shell that encloses the body, excluding the head and neck. A special loading apparatus altered pressure in proportion to respired volume (elastic load) in one of three ways: 1) at the mouth only (T), producing a conventional load in which respiratory muscles are loaded and airway and intrathoracic pressures are made negative in proportion to volume, 2) both at the mouth and in the shell (AW), where the same pattern of airway and intrathoracic pressure occurs but the muscles are not loaded because Prs (i.e., mouth pressure minus pressure in the shell is unchanged, and 3) positive pressure in proportion to volume at the shell only, loading the chest wall but causing no change in airway or thoracic pressures (CW). The threshold for detection (delta E50) with the three types of application was determined in seven normal subjects: 2.16 +/- 0.22, 2.65 +/- 0.54, and 6.21 +/- 0.85 (SE) cmH2O/l for T, AW, and CW, respectively. Therefore the active chest wall, including muscles, is a much less potent source of information than structures affected by the negative airway and intrathoracic pressure. The latter account for the very low threshold for load detection.  相似文献   

20.
A biphasic, anisotropic model of the aortic wall   总被引:4,自引:0,他引:4  
A biphasic, anisotropic elastic model of the aortict wall is developed and compared to literature values of experimental measurements of vessel wall radii, thickness, and hvdraulic conductivity as a function of intraluminal pressure. The model gives good predictions using a constant wall modulus for pressures less than 60 mmHg, but requires a strain-dependent modulus for pressures greater than this. In both bovine and rabbit aorta, the tangential modulus is found to be approximately 20 times greater than the radial modulus. These moduli lead to predictions that, when perfused in a cylindrical geometry, the aortic volume and its specific hydraulic coonductivity are relatively independent of perfusion pressure, in agreement with experimental measurements. M, the parameter that relates specific hydraulic conductivy, to tissue dilation, is found to be a positive quantity correcting a previous error in the literature.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号