首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Electrochemical impedance spectroscopy (EIS) is a widely used technique for probing bioaffinity interactions at the surfaces of electrically conducting polymers. EIS methods can be employed to investigate 'labeless' detection of analytes via impedimetric transduction. This paper describes the development of a direct immunosensor for the detection of a cell-surface protein on Listeria monocytogenes, an extremely important food-borne pathogen. L. monocytogenes are facultative anaerobic, non-sporing, Gram-positive, motile rods that employ the surface bound protein, Internalin B (InlB), to promote invasion into host cells. A recombinant form of InlB was previously cloned and expressed in Escherichia coli and a panel of antibodies and antibody fragments directed against the protein were also produced. Here, we describe how a portion of the recombinant InlB protein, the F3 fragment, and an anti-InlB polyclonal antibody, were used to develop a platform for the labeless immunosensing of InlB. Sensors were fabricated by electropolymerisation of planar screen-printed carbon electrodes with polyaniline (PANI), to produce a conductive substrate. Polyclonal anti-InlB antibody was subsequently incorporated onto the PANI layer using a biotin-avidin system for site-specific immobilisation. The sensors were then probed with varying concentrations of InlB antigen and the impedimetric response at each concentration was recorded. An anti-IgG antibody was immobilised at the electrode surface, as a control and subsequently exposed to the same concentrations of InlB. Impedimetric data for the control sensors were also recorded. Upon exposure to a range of concentrations of antigen, complex plane impedance analyses were used to relate the differing redox states of the polymer layer, to the possible charge transfer at the surface, with respect to the related mechanisms between the antibody and the polymer. These effects were subsequently monitored to assess the impedance of the polymer thereby determining the amount of bound antigen at the sensor surface. Calibration profiles for both sample (InlB) and control (IgG) sensors were constructed. A limit of detection of 4.1 pg/ml was achieved for Internalin B.  相似文献   

2.
This work presents the synthesis of bacteria-mediated bioimprinted films for selective bacterial detection. Marine pathogen sulfate-reducing bacteria (SRB) were chosen as the template bacteria. Chitosan (CS) doped with reduced graphene sheets (RGSs) was electrodeposited on an indium tin oxide electrode, and the resulting RGSs-CS hybrid film served as a platform for bacterial attachment. The electrodeposition conditions were optimized to obtain RGSs-CS hybrid films with excellent electrochemical performance. A layer of nonconductive CS film was deposited to embed the pathogen, and acetone was used to wash away the bacterial templates. Electrochemical impedance spectroscopy was performed to characterize the stepwise modification process and monitor the SRB population. Faradic impedance measurements revealed that the charge transfer resistance (R(ct)) increased with increased SRB concentration. A linear relationship between ΔR(ct) and the logarithm of SRB concentration was obtained within the concentration range of 1.0×10(4)cfumL(-1) to 1.0×10(8)cfumL(-1). The impedimetric sensor showed good selectivity towards SRB based on size and shape. Hence, selectivity for bacterial detection can be improved if the bioimprinting technique is combined with other bio-recognition elements.  相似文献   

3.
An amperometric glucose biosensor with glucose oxidase (GOx) immobilized into palladium hexacyanoferrate (PdHCF) hydrogel has been prepared and evaluated. The sensor was based on a two-layer configuration with biocatalytic and electrocatalytic layers separately deposited onto the electrode. To reduce the overpotential for reduction of hydrogen peroxide liberated in the enzyme catalyzed oxidation of glucose, an inner thin layer of nickel hexacyanoferrate (NiHCF) electrodeposited onto the surface of graphite electrode was used as an electrocatalyst. As an outer layer, the hydrogel of palladium hexacyanoferrate with entrapped glucose oxidase was used. Under optimal operating conditions (pH 5.0 and E = -0.075 V versus calomel (3.0 M KCl) reference electrode), sensor showed high sensitivity to glucose (0.3-1.0 microA/mM) and a response time of less than 30s. The linear response to glucose was obtained in the concentration range between 0.05 and 1.0 mM in batch analysis mode and 0-7.0 mM in FIA. During the 32 days testing period, no significant decrease in the sensor sensitivity was observed. The sensor was applied for the determination of glucose concentration in fruit juice and yoghurt drink, and the results obtained showed good correlation with results obtained by reference spectrophotometric enzyme method.  相似文献   

4.
Min K  Cho M  Han SY  Shim YB  Ku J  Ban C 《Biosensors & bioelectronics》2008,23(12):1819-1824
Tuberculosis is the most frequent cause of infection-related death worldwide. We constructed a simple and direct electrochemical sensor to detect interferon (IFN)-gamma, a selective marker for tuberculosis pleurisy, using its RNA and DNA aptamers. IFN-gamma was detected by its 5'-thiol-modified aptamer probe immobilized on the gold electrode. Interaction between IFN-gamma and the aptamer was recorded using electrochemical impedance spectroscopy and quartz crystal microbalance (QCM) with high sensitivity. The RNA-aptamer-based sensor showed a low detection limit of 100 fM, and the DNA-aptamer-based sensor detected IFN-gamma to 1 pM in sodium phosphate buffer. With QCM analysis, the aptamer immobilized on the electrode and IFN-gamma bound to the aptamer probe was quantified. This QCM result shows that IFN-gamma exists in multimeric forms to interact with the aptamers, and the RNA aptamer prefers the high multimeric state of IFN-gamma. Such a preference may describe the low detection limit of the RNA aptamer shown by impedance analysis. In addition, IFN-gamma was detected to 10 pM by the DNA aptamer in fetal bovine serum, a mimicked biological system, which has similar components to pleural fluid.  相似文献   

5.
A facile, sensitive and reliable impedimetric immunosensor doped with reduced graphene sheets (RGSs) and combined with a controllable electrodeposition technique was developed for the selective detection of marine pathogenic sulphate-reducing bacteria (SRB). The morphology of RGSs and the electrochemical properties of RGSs-doped chitosan (CS) nanocomposite film were investigated by atomic force microscopy, Fourier transform infrared spectroscopy, and cyclic voltammetry (CV). Electrochemical impedance spectroscopy and CV were used to verify the stepwise assembly of the sensor system. Faradic impedance spectroscopy for charge transfer for the redox probe Fe(CN)(6)(3-/4-) was done to determine SRB concentrations. The diameter of the Nyquist diagram that is equal to the charge-transfer resistance (R(ct)) increased with increasing SRB concentration. A linear relationship between R(ct) and SRB concentration was obtained in the SRB concentration range of 1.8×10(1) to 1.8×10(7) cfu/ml. The impedimetric biosensor gave a distinct response to SRB, but had no obvious response to Vibrio angillarum. It showed a high selectivity for the detection of the pathogen. Based on a combination of the biocompatibility of CS and good electrical conductivity of RGSs, a nanocomposite film with novel architecture was used to immobilize biological and chemical targets and to develop a new type of biosensor.  相似文献   

6.
Label-free detection of bisphenol A based on the impedance measurement was achieved with an impedimetric immunosensor. The immunosensor was fabricated by the covalent bond formation between a polyclonal antibody and a carboxylic acid group functionalized onto a nano-particle comprised conducting polymer. By using a commercial reagent 4,4-bis(4-hydroxyphenyl) valeric acid (BHPVA), which has an analogous structure of BPA, we have prepared the antigen through the conjugation of BHPVA with bovine serum albumin (BSA) and then produced a specific polyclonal antibody. The immobilization of antibody and the interaction between antibody and antigen were studied using quartz crystal microbalance (QCM) and electrochemical impedance spectroscopic (EIS) techniques. The impedance and mass changes due to the specific immuno-interaction at the sensor surface were utilized to detect antigen and bisphenol A (BPA). The immunosensor showed specific recognition of BPA with less interference than 4.5% from other common phenolic compounds. Under an optimized condition, the linear dynamic range of BPA detection was between 1 and 100 ng/ml. The detection limit of bisphenol A was determined to be 0.3+/-0.07 ng/ml. The proposed immunosensor was applied to a human serum sample and the BPA concentration was determined by the standard addition method.  相似文献   

7.
A sensitive and selective immunosensor for the nonlabeled detection of sulfate-reducing bacteria (SRB) is constructed using a self-polymerised polydopamine film as the immobilisation platform. Self-polymerisation of dopamine is used as a powerful approach for applying multifunctional coatings onto the surface of a gold electrode. The polydopamine film is used not only as the immobilisation platform, but also as a cross-linker reagent for the immobilisation of the anti-SRB antibody. The polydopamine film is loaded with a high density of anti-SRB antibodies linked to the substrate to obtain high response signals. The formation and fabrication of the biosensor and the quantification of antibody anchoring are monitored, and SRB detection is performed by either quartz crystal microbalance (QCM) or electrochemical impedance spectroscopy (EIS). After modeling the impedance Nyquist plots of the SRB/anti-SRB/polydopamine/gold electrode for increasing concentrations of SRB, the electron transfer resistance (R(ct)) is used as a measure of immunocomplex binding. The R(ct) is correlated with the concentration of bacterial cells in the range of 1.8×10(2) to 1.8×10(6) CFU mL(-1); the detection limit is 50 CFU mL(-1). This work demonstrates a new immobilisation platform for the development of a sensitive and label-less impedimetric and piezoelectric immunosensor. This immunosensor may be broadly applied in clinical diagnoses and the monitoring of water environmental pollution. The method proposed is distinct in its ease of application, use of a simple protocol, and mild reaction conditions. These allow it to be applied to a wide variety of materials.  相似文献   

8.
This study presents the time-resolved detection of chemically induced stress upon intracellular signaling cascades by using genetically modified sensor cells based on the human keratinocyte cell line HaCaT. The cells were stably transfected with a HSP72-GFP reporter gene construct to create an optical sensor cell line expressing a stress-inducible reporter protein. The time- and dose-dependent performance of the sensor cells is demonstrated and discussed in comparison to a label-free impedimetric monitoring approach (electric cell-substrate impedance sensing, ECIS). Moreover, a microfluidic platform was established based on μSlidesI(0,4)Luer to allow for a convenient, sterile and incubator-independent time-lapse microscopic observation of the sensor cells. Cell growth was successfully achieved in this microfluidic setup and the cellular response to a cytotoxic substance could be followed in real-time and in a non-invasive, sensitive manner. This study paves the way for the development of micro-total analysis systems that combine optical and impedimetric readouts to enable an overall quantitative characterization of changes in cell metabolism and morphology as a response to toxin exposure. By recording multiple parameters, a detailed discrimination between competing stress- or growth-related mechanisms is possible, thereby presenting an entirely new in vitro alternative to skin irritation tests.  相似文献   

9.
An impedimetric mga gene specific DNA sensor was developed by immobilization of single stranded DNA probe onto the screen printed modified gold-dendrimer nanohybrid composite electrode for early and rapid detection of S. pyogenes in human throat swab samples causing rheumatic heart disease. Electrochemical impedance response was measured after hybridization with bacterial single stranded genomic DNA (ssG-DNA) with probe. The sensor was found highly specific to S. pyogenes and can detect as low as 0.01 ng ssDNA in 6 µL sample only in 30 min. The nanohybrid sensor was also tested with non-specific pathogens and characterized by FTIR. An early detection of the pathogen S. pyogenes in human can save damage of mitral and aortic heart valves (rheumatic heart disease) by proper medical care.  相似文献   

10.
We have reported that nanowell array (NWA) can enhance electrochemical detection of molecular binding events by controlling the binding sites of the captured molecules. Using NWA biosensor based amperometric analysis, we have detected biological macromolecules such as DNA, protein or aptamers at low concentrations. In this research, we developed an impedimetric immunosensor based on wafer-scale NWA for electrochemical detection of stress-induced-phosphoprotein-1 (STIP-1). In order to develop NWA sensor through the cost-effective combination of high-throughput nanopattern, the NWA electrode was fabricated on Si wafer by krypton-fluoride (KrF) stepper semiconductor process. Finally, 12,500,000 ea nanowell with a 500 nm diameter was fabricated on 4 mm × 2 mm substrate. Next, by using these electrodes, we measured impedance to quantify antigen binding to the immunoaffinity layer. The limit of detection (LOD) of the NWA was improved about 100-fold compared to milli-sized electrodes (4 mm × 2 mm) without an NWA. These results suggest that wafer-scale NWA immunosensor will be useful for biosensing applications because their interface response is appropriate for detecting molecular binding events.  相似文献   

11.
In this study, electrical impedimetric biosensors composed of Au-electrodes were fabricated for the quantitative detection of human serum albumin (HSA), an essential biomarker of liver function. The Au-electrodes were fabricated via a single-step photolithography process, and can be easily integrated in biochips for assessing liver function in the future. The glass sensing surface between two adjacent Au-electrodes was modified with 3-aminopropyltriethoxysilane (APTES) to improve the biocompatibility for its subsequent binding to anti-human serum albumin (AHSA). The sensing surface without AHSA binding was blocked using skim milk powders, preventing possible non-specific bonding HSA conjugation. Biosensors were used to measure HSA concentration for liver function detection. The impedance between two adjacent Au-electrodes of the biosensors applied with various HSA concentrations was directly measured, and quantified using an electrochemical impedance spectroscopy system under AC conditions. The results of plotting both values in log scales indicated the impedance increased linearly with HSA conjugation increase. The limit of HSA detection was about 2'10(-4)mg/ml using the electrochemical impedimetric biosensor proposed in this work. This study demonstrates the feasibility of using electrochemical impedimetry as a bio-sensing mechanism to quantify human serum albumin concentration. The sensor proposed in this work also displays great potential for assessing liver function because of its simple detection mechanism, ease of biochip integration, and low cost.  相似文献   

12.
This paper proposes a very simple procedure for preparing a biocompatible sensor based on a protein (bovine serum albumin, BSA), enzyme and vinylferrocene (VF) composite membrane modified electrode. The membrane was prepared simply by first casting vinylferrocene and then coating it with BSA and glucose oxidase immobilised with glutaraldehyde. The sensor response was independent of dissolved oxygen concentration from 3 to 10 ppm and showed good stability for serum sample measurement, unlike the commonly used BSA/enzyme modified electrode. The sensor response was almost unchanged over the measurement time (>10 h) whereas the responses of a BSA and glucose oxidase modified platinum electrode and an osmium-polyvinylpyridine wired horseradish peroxidase modified electrode (Ohara et al., 1993) fell to 68% of their initial value in a serum sample containing 10mM glucose.  相似文献   

13.
Deferrioxamine, a bacterial hydroxamic siderophore having high binding affinity for Fe(III), is used in its immobilized form, as self-assembled monolayer on Au, for accumulation and recognition of Fe(III) from the solution phase. The accumulated Fe(III) is detected via both active mode based on faradaic reduction current of Fe(III), and inactive mode based on impedimetric effect of accumulated Fe(III) against redox reaction of a suitable probe. Appropriate electrochemical techniques, square wave voltammetry and electrochemical impedance spectroscopy, are used for the transduction of analytical signals obtained by this sensor. Then, the parameters influencing the sensor response are optimized. In the best conditions, a linear response, from 1.0×10(-10) to 1.0×10(-7)M Fe(III) in logarithmic scale with a detection limit of 2.0×10(-11)M, and mean relative standard deviation of 1.7% for n=4 is observed. The results show that the sensor can be used for determination of Fe(III) in the presence of various inorganic ions and biological species. Validity of the method and applicability of the sensor are successfully tested by determination of Fe(III) in various real samples including plant tissue (corn leaves), industrial alloy (Ferrotitanium), and pharmaceutical samples (Venofer(?) ampoule, Ironorm(?) capsule, and V.M. Protein(?) powder).  相似文献   

14.
This study reports on the electropolymerization of a low toxic and biocompatible nanopolymer with entitle poly arginine‐graphene quantum dots‐chitosan (PARG‐GQDs‐CS) as a novel strategy for surface modification of glassy carbon surface and preparation of a new interface for measurement of malondialdehyde (MDA) in exhaled breath condensate. Electrochemical deposition, as a well‐controlled synthesis procedure, has been used for subsequently layer‐by‐layer preparation of GQDs‐CS nanostructures on a PARG prepolymerized on the surface of glassy carbon electrode using cyclic voltammetry techniques in the regime of ?1.5 to 2 V. The modified electrode appeared as an effective electroactivity for detection of MDA by using cyclic voltammetry, linear sweep voltammetry, and differential pulse voltammetry. The prepared modified electrode demonstrated a noticeably good activity for electrooxidation of MDA than PARG. Enhancement of peak currents is ascribed to the fast heterogeneous electron transfer kinetics that arise from the synergistic coupling between the excellent properties of PARG and semiconducting polymer, GQDs as high density of edge plane sites and subtle electronic characteristics and unique properties of CS such as excellent film‐forming ability, high permeability, good adhesion, nontoxicity, cheapness, and a susceptibility to chemical modification. The prepared sensor showed 1 oxidation processes for MDA at potentials about 1 V with a low limit of quantification 5.94 nM. Finally, application of new sensor for determination of MDA in exhaled breath condensate was suited. In general, the simultaneous attachment of GQDs and CS to structure of poly amino acids provides new opportunities within the personal healthcare.  相似文献   

15.
Sensitivity of Anthrax protective antigen (PA) detection has been improved by directly immobilizing a PA-specific peptide onto a multi-wall carbon nanotube (MWCNT). The MWCNT was covalently immobilized onto a polyaniline (PANI) electrode, which was prepared via electropolymerization of the aniline monomer onto a glassy carbon electrode (GCE). Then, the PA-specific peptide was covalently immobilized to the MWCNT layer for measurement. When comparing this technique to that of PA immobilization on an insulting self assembled organic layer, the advantages of the MWCNT are clear. The MWCNT sensor resulted in enhanced electron transfer across the sensing layer. The resulting limit of detection (LOD) was 0.4 pM, a 13-fold improvement over that of our previous self-assembled organic layer was used for immobilization of the same peptide. Neither positive nor negative interferences were observed when a sample containing both 100 pM PA and bovine serum albumin (BSA) was measured, indicating good selectivity of the proposed sensor.  相似文献   

16.
The detection of cancer biomarkers is as important tool for the diagnosis and prognosis of cancer such as brain cancer. Murine double minute 2 (MDM2) has been widely studied as prognostic marker for brain tumor. Here we describe development of a new sensitive label free impedimetric immunosensor for the detection of MDM2 based on cysteamine self assembled monolayers on a clean polycrystalline Au electrode surface. The amine-modified electrodes were further functionalized with antibody using homobifunctional 1,4-phenylene diisothiocyanate (PDITC) linker. The assembly processes of the immunosensor had been monitored with cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) techniques using Fe(CN)(6)(3-/4-) solution as redox probe. The impedance changes upon binding of MDM2 protein to the sensor surface was utilized for the detection of MDM2. The increase in relative electron-transfer resistance (ΔR/R(0)%) values was linearly proportional to the concentration of tumor marker MDM2 in the wide dynamic range of 1pg/ml-1μg/ml. The limit of detection was 0.29pg/ml in phosphate buffer saline (PBS) and 1.3pg/ml in mouse brain tissue homogenate, respectively. The immunosensor showed a good performance in comparison with ELISA for the analysis of the MDM2 in the cancerous mouse brain tissue homogenates. Moreover, the immunosensor had a good selectivity against epidermal growth factor receptor (EGFR) protein, long-storage stability and reproducibility. It might be become a promising assay for clinical diagnosis and early detection of tumors.  相似文献   

17.
Qiu S  Gao S  Liu Q  Lin Z  Qiu B  Chen G 《Biosensors & bioelectronics》2011,26(11):4326-4330
Copper(I) species can be acquired from the reduction of copper(II) by ascorbic acid (AA) in situ, and which in turn quantitative catalyze the azides and alkynes cycloaddition reaction. In this study, propargyl-functionalized ferrocene (propargyl-functionalized Fc) has been modified on the electrode through reacting with azide terminal modified Au electrode via copper(I) catalyzed azides and alkynes cycloaddition (CuAAC) reaction. The electrochemical impedance spectroscopy (EIS) measurement has been applied to test the electron transfer resistance of the Au electrode before and after click reaction. The changes of the fractional surface coverage (θ) with different AA concentrations are characterized. It is found that the θ value has a linear response to the logarithm of AA concentration in the range of 5.0 pmol/L to 1.0 nmol/L with the detection limits of 2.6 pmol/L. The sensor shows a good stability and selectivity. And it has been successfully applied to the AA detection in the real samples (urine) with satisfactory results.  相似文献   

18.
A potentiometric enzyme electrode for the direct measurement of organophosphate (OP) nerve agents was developed. The basic element of this enzyme electrode was a pH electrode modified with an immobilized organophosphorus hydrolase (OPH) layer formed by cross-linking OPH with bovine serum albumin (BSA) and glutaradehyde. OPH catalyses the hydrolysis of organophosphorus pesticides to release protons, the concentration of which is proportional to the amount of hydrolysed substrate. The sensor signal and response time was optimized with respect to the buffer pH, ionic concentration of buffer, temperature, and units of OPH immobilized using paraoxon as substrate. The best sensitivity and response time were obtained using a sensor constructed with 500 IU of OPH and operating in pH 8.5, 1 mM HEPES buffer. Using these conditions, the biosensor was used to measure as low as 2 microM of paraoxon, ethyl parathion, methyl parathion and diazinon. The biosensor was completely stable for at least one month when stored in pH 8.5, 1 mM HEPES + 100 mM NaCl buffer at 4 degrees C.  相似文献   

19.
Electrochemical impedance spectroscopy (EIS) as a powerful, non-invasive and informative technique was used to obtain important information about kinetics of doping process in conducting polymers. Polypyrrole (PPy) and its derivatives can form conducting polymer films which represent excellent charge transfer behaviors during doping processes. It can also have a wide range of applications in bioelectrochemistry. In the present study the conducting polymer of alpha-carboxy pyrrole (alpha-COOH-PPy), appended onto the underlying film of PPy, was prepared by electrochemical methods and its behavior was analyzed using EIS. From highly accurate fitting of impedance results it was found that the charging mechanism is governed by the diffusion process. In addition, the impedance analyses provided values for the bulk polymer parameters including diffusion coefficient (D), equilibrium capacitance (C(0)) and diffusion resistance (R(0)). The surface morphology of the polymeric film was characterized using scanning electron microscopy (SEM). The film was then used to immobilize the cytochrome C (cyt-C) and to perform its electrochemical studies. The modified cyt-C/alpha-COOH-PPy electrode was used for electrocatalytic reduction of H(2)O(2) in solution and its viability as a new impedimetric biosensor was examined. Based on the calibration curve obtained for the proposed impedimetric biosensor, the limit of detection and relative standard deviation were evaluated as 0.25mumolL(-1) and 7%, respectively. Finally, the prolonged stability test was performed and high stability and reproducibility of the new biosensor was confirmed.  相似文献   

20.
A voltammetric sensor for (-)-ephedrine has been prepared by a novel approach based on immobilisation of an imprinted polymer for ephedrine (MIPE) in an electrosynthesised polypyrrole (PPY) film. Composite films were grown potentiostatically at 1.0 V vs. Pt (QRE) on a glassy carbon electrode using an unconventional "upside-down" (UD) geometry for the three-electrode cell. As a consequence, a high MIP loading was obtained, as revealed by SEM. The sensor response was evaluated, after overoxidation of PPY matrix, by cyclic voltammetry after pre-concentration in a buffered solution of analyte in 0.5-3 mM concentration range. An ephedrine peak at approximately 0.9 V increasing with concentration and saturating at high concentrations was evident. PPY-modified electrode showed a response, which was distinctly lower than the MIP response for the same concentration of the template. The effect of potential interferences including compounds usually found in human fluids (ascorbic acid, uric acid, urea, glucose, sorbitol, glycine, dopamine) was examined.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号