共查询到20条相似文献,搜索用时 0 毫秒
1.
R. Huupponen 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1992,583(2)
A high-performance liquid chromatographic method for the determination of metformin, an oral antidiabetic agent, in plasma is described. Plasma samples containing the internal standard, phenformin, are eluted through Amprep extraction columns before injection into the chromatographic column, packed with μBondapak phenyl. The eluent is monitored at 236 nm. At a mobile phase flow-rate of 1.35 ml/min, the retention times of metformin and phenformin are 2.8 and 5.6 min, respectively. The intra-day coefficients of variation are 1.5 and 4.3% at metformin concentrations of 0.05 and 1 mg/l, respectively. 相似文献
2.
Gerard Forrest Graeme J. Sills John Paul Leach Martin J. Brodie 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1996,681(2):421
A rapid and simple method for determination of the novel antiepileptic compound gabapentin [1-(aminomethyl)cyclohexaneacetic acid] in plasma is described. Blank human plasma was spiked with gabapentin (1.0–10.0 μg/ml) and internal standard [1-(aminomethyl)-cycloheptaneacetic acid; 5.0 μg/ml]. Individual samples were treated with 2 M perchloric acid, centrifuged and then derivatised with o-phthalaldehyde-3-mercaptopropionic acid. Separation was achieved on a Beckman Ultrasphere 5 μm reversed-phase column with mobile phase consisting of 0.33 M acetate buffer (pH 3.7; containing 100 mg/l EDTA)-methanol-acetonitrile (40:30:30, v/v). Eluents were monitored by fluorescence spectroscopy with excitation and emission wavelengths of 330 and 440 nm, respectively. The calibration curve for gabapentin in plasma was linear (r=0.9997) over the concentration range 1.0–10.0 μg/ml. Recovery was seen to be 90%. The inter- and intra-assay variations for three different gabapentin concentrations were 10% throughout. The lower limit of quantitation was found to be 0.5 μg/ml. Chromatography was unaffacted by a range of commonly employed antiepileptic drugs or selected amino acids. 相似文献
3.
Hernn Speisky Bruce K. Cassels Susana Nieto Alfonso Valenzuela Luis J. Nuez-Vergara 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1993,612(2)
A sensitive method for the determination of boldine in blood plasma is described. The procedure involves a direct pH-buffered chloroform extraction of boldine from blood plasma, followed by its assay under isocratic conditions by HPLC with UV detection. The extraction recovery is excellent, and sensitivity and precision of the method are very high, when applied to plasma samples containing pharmacologically relevant concentrations of boldine. 相似文献
4.
5.
6.
7.
8.
9.
10.
11.
《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1996,685(1):123-127
An assay has been developed and validated for the routine monitoring of mivacurium in plasma. It consists of liquid-liquid extraction with dichloromethane and high-performance liquid chromatography with fluorometric detection (excitation and emission wavelengths 220 nm and 320 nm, respectively). A Spherisorb C1 5 μm column and a mobile phase containing acetonitrile, KH2PO4 and methanol are used. At a flow-rate of 1 ml/min, a concentration gradient is applied. The detection limit is approximately 1 ng/ml in plasma. For the separation of stereoisomeres, the Spherisorb SCX 10 μm column and acetonitrile-Na2SO4 as a mobile phase can be used. The assay shows good linearity over the range 1–1000 ng/ml. The accuracy and precision allows the utilisation in clinical pharmacokinetic studies. 相似文献
12.
13.
14.
15.
16.
17.
18.
19.
J. Havard 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1992,584(2):270-274
An assay using reversed-phase high-performance liquid chromatography with electrochemical detection was developed to measure hydroxyurea in plasma at concentrations suitable for pharmacokinetic studies. The sample preparation is simple, the analysis rapid and assays can be batched. The between-run precision is excellent (coefficient of VARIATION = 2.8–4.5%) and the limit of detection is 0.02 mmol/l. Preliminary studies have shown that the method is suitable for pharmacokinetic studies. 相似文献
20.
《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1997,689(1):239-243
A new method for the determination of omeprazole in human plasma was developed. Omeprazole was extracted from plasma with toluene-isoamylalcohol (95:5, v/v), the organic phase was evaporated, dissolved in the mobile phase and injected into a reversed-phase C18 column. Flunitrazepam was used as an internal standard. The mobile phase consisted of 47% methanol and 53% of 0.1 M dipotassium hydrogenphosphate, pH 7.8. The spectrophotometric detection was performed at 302 nm. Limit of quantitation was 9.7 ng/ml and the calibration curve was linear up to 1240 ng/ml. 相似文献