首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A highly sensitive method for the determination of tamsulosin hydrochloride, a structurally new type of sulphamoile derivative, in human plasma dialysate, plasma and urine has been developed by using liquid chromatography–electrospray tandem mass spectrometry (LC–MS–MS). Plasma dialysate, plasma and urine samples were extracted by brief liquid-phase extraction and analyzed using an HPLC system coupled to a mass spectrometer via an electrospray ionization interface. Selected reaction monitoring was used for the detection of tamsulosin and its internal standard. This method was validated in the concentration range 10–1000 pg/ml in plasma dialysate, 0.5–50 ng/ml in plasma, and 1–100 ng/ml in urine with sufficient specificity, accuracy and precision. The in vivo protein binding study demonstrated that the unbound tamsulosin in human plasma obtained by the equilibrium dialysis after 0.4-mg oral dosing was measurable. In addition, the percentage of unbound tamsulosin in an in vitro study (0.71–0.91%) obtained by using spiked 14C-labelled tamsulosin was slightly larger than that of the in vivo study (0.68–0.86%), indicating that the unbound concentration calculated by the product of the plasma concentration and the in vitro unbound fraction (fu) was unfavorably overestimated. These results suggest that the combination of LC–MS–MS and equilibrium dialysis method has enough sensitivity to determine the unbound concentration in clinical use and gives the concentration more exactly than the in vitro fu.  相似文献   

2.
A fully automated screening using liquid chromatography–mass spectrometric method applying data-dependent acquisition was developed to identify toxicologically relevant substances in serum and urine. A library including more than 405 spectra of about 365 compounds (main drugs and important metabolites) was established. An easy to use program was created to automate and accelerate library search. Drugs were identified based on their relative retention times, molecular ions and fragment ions. Limits of detection were tested with 100 of the 365 compounds the majority of these were lower than 100 μg/l (67%). The developed LC–MS–MS system seems to be a valuable alternative to other general unknown screening methods allowing fast and specific identification of drugs in serum and urine samples.  相似文献   

3.
Microcystins (MC) and nodularins (Nod) are cyclic peptide hepatotoxins and tumour promoters produced by cyanobacteria. This study deals with liquid chromatography–mass spectrometry (LC–MS) analyses of 9 major cyanobacterial peptide toxins, starting with a comparison of six small particle size reversed-phase HPLC columns, from which one, Phenomenex Synergi Hydro-RP, was chosen for further chromatography with accurate mass MS studies in a complex biological fluid, serum. The instrumentation used for the serum sample analysis included a Bruker micrO-TOF-Q-MS coupled to an Agilent 1200RR LC system. Total analysis run time per sample was 8.5 min. The Q-TOF-MS instrument was operated on auto MS–MS mode to obtain fragment ions (such as the characteristic fragment m/z 135 from Adda amino acid residue) for toxin identification purposes. Detected mass errors in serum samples were in the range of from 0.3 mDa to 9.1 mDa. The narrow mass window (±20 mDa) for mass chromatograms used in quantitation gave benefits by background noise reduction. We conclude that a LC–ESI-Q-TOF-MS instrumentation is a powerful tool for identification and quantitation of cyanobacterial peptide toxins in a biological matrix.  相似文献   

4.
To reliably identify the residual tetracycline antibiotics (TCs), oxytetracycline (OTC), tetracycline, chlortetracycline (CTC) and doxycycline (DC), in bovine tissues, we have established a confirmation method using electrospray ionization liquid chromatography–tandem mass spectrometry (ESI LC–MS–MS) with daughter ion scan. All TCs gave [M+H−NH3]+ and [M+H−NH3−H2O]+ as the product ions, except for DC when [M+H]+ was selected as the precursor ion. The combination of C18 cartridge clean-up and the present ESI LC–MS–MS method can reliably identify TCs fortified at a concentration of 0.1 ppm in bovine tissues, including liver, kidney and muscle, and has been successfully applied to the identification of residual OTC in bovine liver and residual CTC in bovine muscle samples previously found at concentrations of 0.58 ppm and 0.38 ppm by LC, respectively.  相似文献   

5.
Morphine (MOR) is an opioid analgesic used for the treatment of moderate to severe pain. MOR is extensively metabolized to morphine-3-glucuronide (M3G) and morphine-6-glucuronide (M6G). A rapid and sensitive method that was able to reliably detect at least 0.5 ng/ml of MOR and 1.0 ng/ml of M6G was required to define their pharmacokinetic profiles. An LC–MS–MS method was developed in our laboratory to quantify all three analytes with the required sensitivity and a rapid turnaround time. A solid-phase extraction (SPE) was used to isolate MOR, M3G, M6G, and their corresponding deuterated internal standards from heparinized plasma. The extract was injected on a LC tandem mass spectrometer with a turbo ion-spray interface. Baseline chromatographic separation among MOR, M3G, and M6G peaks was achieved on a silica column with an aqueous organic mobile phase consisting of formic acid, water, and acetonitrile. The total chromatographic run time was 3 min per injection, with retention times of 1.5, 1.9 and 2.4 min for MOR, M6G, and M3G, respectively. Chromatographic separation of M3G and M6G from MOR was paramount in establishing the LC–MS–MS method selectivity because of fragmentation of M3G and M6G to MOR at the LC–MS interface. The standard curve range in plasma was 0.5–50 ng/ml for MOR, 1.0–100 ng/ml for M6G, and 10–1000 ng/ml for M3G. The inter-day precision and accuracy of the quality control (QC) samples were <7% relative standard deviation (RSD) and <6% relative error (R.E.) for MOR, <9% RSD and <5% R.E. for M6G, and <3% RSD and <6% R.E. for M3G. Analyte stability during sample processing and storage were established. Method ruggedness was demonstrated by the reproducible performance from multiple analysts using several LC–MS–MS systems to analyze over one thousand samples from clinical trials.  相似文献   

6.
A liquid chromatographic–tandem mass spectrometric (LC–MS–MS) method was developed for the quantitation of urinary leukotriene E4 (LTE4). LTE4 and its internal standard were extracted by solid-phase extraction and analysed using LC–MS–MS in the selected reaction monitoring (SRM) mode. A good linear response over the range of 10 pg to 10 ng was demonstrated. The accuracy of added LTE4 ranged from 97.0% to 108.0% with a mean and SD of 100.6±2.4%. We detected LTE4 (63.1±18.7 pg/mg creatinine, n=10) in healthy human urine. This method can be used to determine LTE4 in biological samples.  相似文献   

7.
The discrepancy of results for the quantification of androstenedione in human serum between a radioimmunoassay (RIA) method and high performance liquid chromatography tandem-mass spectrometry (LC–MS/MS) was investigated. RIA overestimated concentrations compared to LC–MS/MS on 59 clinical samples (RIA = 1.79 × LC–MS/MS + 0.94). RIA kit and LC–MS/MS calibrants were also determined by both methods. The RIA performed with improved accuracy on the calibrants (RIA = 1.35 × LC–MS/MS − 0.28). Lipid, protein, electrolyte content, and pH of the two sets of calibrants were further investigated. The RIA calibrants contained little lipid material, while the LC–MS/MS calibrant material contained the same levels expected in normal serum/plasma. The pH and sex hormone binding globulin (SHBG) values were different between the RIA calibrants and the LC–MS/MS calibrant material (SHBG, 31 ± 2 and 38 ± 2 nmol/l; pH, 8.27 ± 0.18 and 8.66 ± 0.03, respectively). No correlation was observed between androstenedione RIA and LC–MS/MS discrepancy and lipid or protein. LC–MS/MS sample preparation was tested for the removal of protein-bound material and recovery determined (99–108%). The corresponding RIA results overestimated androstenedione by 52–174% compared to LC–MS/MS. The results here demonstrate that LC–MS/MS is the more accurate method.  相似文献   

8.
We present fast LC–MS–MS analyses of multicomponent mixtures containing flavones, sulfonamides, benzodiazepines and tricyclic amines. Using a short microbore HPLC column with small particle size, five to eight compounds were partially resolved within 15 to 30 s. TurboIonSpray and atmospheric pressure chemical ionization interfaces were well suited to tolerate the higher eluent flow-rates of 1.2 to 2 ml/min. The methods were applied to biological sample matrices after clean-up using solid-phase or liquid–liquid extraction. Good precision and accuracy (average 8.9 and 97.7%, respectively) were achieved for the determination of tricyclic amines in human plasma. Benzodiazepines were determined in human urine with average precision of 9% and average accuracy of 95% for intra- and inter-assay. Detection limits in the low ng/ml range were obtained. An example for 240 injections per hour of demonstrated the feasibility of rapid LC–MS–MS analysis.  相似文献   

9.
Analytical methods for the determination of cloxacillin, ampicillin/hetacillin, and amoxicillin in bovine milk were developed. The methods involved ultrafiltration of milk diluted with methanol, acetonitrile, and water on a 10 000-dalton cut-off filter. Separation of penicillins from other milk components was accomplished by ion-paired chromatography using a microbore column. The penicillins were detected using ultraviolet photodiode array (UV-PDA) detection and confirmed by thermospray liquid chromatography—mass spectrometry (LC—MS). The thermospray spectra of these compounds exhibited [M + H]+ and [M + Na]+ ions along with several fragment ions. The limits of detection for these antibiotics were estimated to be 50 to 100 ppb for LC with UV-PDA detection and 100–200 ppb for thermospray LC—MS detection.  相似文献   

10.
A sensitive, reproducible, and rapid analytical method for the analysis of trace-level heterocyclic amines (HCAs) that are expected to have high levels of human exposure was developed. Liquid–liquid extraction (LLE) with dichloromethane (DCM) followed by solid-phase extraction (SPE) was carried out. Liquid extraction with DCM under basic conditions was efficient in extracting HCAs from urine samples. For further purification, mixed mode cationic exchange (MCX) cartridges were applied to eliminate the remaining interferences after liquid extraction. Separation and quantification were performed by liquid chromatography coupled with tandem mass spectrometry (LC–MS/MS) in selected reaction monitoring (SRM) mode. The overall recoveries ranged between 71.0% and 113.6% with relative standard deviations (RSDs) of 5.1% to 14.7% for the entire procedure. The limits of detection (LODs) and limits of quantification (LOQs) of the proposed analytical method were in the ranges of 0.04 to 0.10 ng/ml and 0.15 to 0.36 ng/ml, respectively. This method was applied to the analysis of monitoring in urine samples for Korean school children, and the results demonstrated that the method can be used for the trace determination of HCAs in urine samples.  相似文献   

11.
A specific method for the determination of erythromycin 2'-ethylsuccinate (EM-ES) in plasma is described. The method involves a liquid—liquid extraction procedure followed by the analysis of extracts using phase-system switching (PSS) continuous-flow fast atom bombardment (CF-FAB) liquid chromatography—mass spectrometry (LC—MS). In PSS EM-ES is enriched after analytical separation on a short trapping column, from which it is desorbed to the LC—MS interface. In this way, favourable mobile phases can be used for the LC separation and for the MS detection. Using the PSS approach a flow-rate reduction from 1.0 ml/min in the LC system to 15 μl/min going into the mass spectrometer was achieved without splitting. The determination limit for EM-ES was 0.1 μg/ml.  相似文献   

12.
An LC–MS–MS method for the analysis of the neuraminidase inhibitor, zanamivir, in human serum is described. Zanamivir was extracted from protein precipitated human serum samples using Isolute SCX solid-phase extraction cartridges and analysed using reversed-phase chromatography with TurboIonSpray atmospheric pressure ionisation followed by mass spectrometric detection. The method uses a stable isotope internal standard, is highly specific and sensitive for a compound of this type and has been used for the analysis of human serum and urine samples from clinical studies. The method was extended to the analysis of serum and plasma samples from pre-clinical studies involving the rat, ferret and cell culture media. The method has been shown to be robust and valid over a concentration range of 10–5000 ng/ml using a 0.2-ml sample volume. The main advantages of this method compared to earlier procedures are primarily specificity, sensitivity, ease of sample preparation, small sample volume and short analysis time (ca. 5 min).  相似文献   

13.
Short narrow analytical HPLC columns have been used successfully with high linear flow-rates and combined with mass spectrometric detection to produce a generic approach to quantitative bioanalysis. The approach has been used to validate several assays in the low ng/ml region and an example is given in this paper. When combined with a simple solid-phase extraction process the need for complicated, time consuming method development has been removed for the majority of pharmaceutical compounds. The approach takes advantage of not only the extra selectivity of the MS–MS detector but the excellent resolution and peak shape produced by gradient elution.  相似文献   

14.
A liquid chromatography–electrospray ionization tandem mass spectrometric method was developed for the simultaneous determination of losartan and its major active metabolite, EXP-3174, in human plasma. The two analytes and the internal standard (DuP-167) were extracted from plasma under acidic conditions by using solid-phase extraction cartridges containing a sorbent of copolymer, poly(divinylbenzene-co-N-vinylpyrrolidone). The analytes were separated by LC equipped with a reversed-phase C18 column, and introduced into the mass spectrometer via the electrospray ion source with pneumatically-assisted nebulization. For LC–MS–MS samples, an isocratic mobile phase consisting of [0.1% triethylamine–0.1% acetic acid (pH 7.1)]–acetonitorile (65:35, v/v) was used, and the assay was monitored for the negative fragment ions of the analytes. The method demonstrated linearity from 1 to 1000 ng/ml for both losartan and EXP-3174. The limit of quantification for both compounds in plasma was 1 ng/ml. This assay method may be useful for the measurement of levels of the two compounds in clinical studies of losartan.  相似文献   

15.
The liquid chromatography–multiple reaction monitoring–tandem mass spectrometry (LC–MRM–MS/MS) method using 13C stable isotope-labeled dipeptides was newly developed to simultaneously determine the absorption of three antihypertensive peptides (Val-Tyr, Met-Tyr, and Leu-Tyr) into blood of spontaneously hypertensive rats in one run-in assay. After extracting 13C-labeled peptides in blood sample with a C18 cartridge, the extract was applied to a 13C monoisotopic transition LC–MRM–MS/MS system with d-Val-Tyr included as internal standard. An excellent separation of each dipeptide in LC was achieved at the elution condition of 5–100% methanol in 0.1% formic acid at a flow rate of 0.25 ml/min. The 13C-labeled peptides ionized by electron spray were detected in the positive ion mode within 15 min. The established method showed high reproducibility with less than 10% coefficient of variation as well as high accuracy of more than 85%. After the administration of a mixture containing the three 13C-labeled dipeptides to rats at each dose of 30 mg/kg, we could successfully determine the intact absorption of each 13C-labeled peptide with the maximal absorption amount of 1.1 ng/ml plasma for Val-Tyr by the proposed LC–MRM–MS/MS method.  相似文献   

16.
Adenosine-secreting cellular brain implants constitute a promising therapeutic approach for the treatment of epilepsy. To engineer neural stem cells for therapeutic adenosine delivery, a reliable and fast analytical method is necessary to quantify cell-based adenosine release. Here we describe the development, optimization and validation of adenosine measurement using liquid chromatography–atmospheric pressure chemical ionization-tandem mass spectrometry (LC–APCI-MS/MS). LC–MS/MS in positive ion mode used selected reaction monitoring at m/z of 268.2/136.1 and 302.2/170.0 for adenosine and the internal standard, respectively. The bias was within 15% of the nominal value and evaluation of precision showed a relative standard deviation lower than 15% for all measured concentrations. The lower limit of quantification of adenosine was 15.6 ng/ml. Freeze and thaw stability and processed sample stability also fulfilled the acceptance criteria. Evaluation of the matrix effect showed that the method is not affected by relative matrix effects. The major advantages of this method are the absence of an extraction phase and the combination of the high selectivity and sensitivity characteristic for the LC–MS/MS technique, with a short run time of 4.5 min. These results demonstrate that this method is a useful tool to measure adenosine concentrations in culture medium released from stem cells in vitro.  相似文献   

17.
Positive ion mass spectra were obtained from several coumarin oral anticoagulants (phenprocoumon, warfarin, acenocoumarol and dicoumarol) and derivatives by liquid chromatography—thermospray mass spectrometry (LC—TSP-MS) and liquid chromatography—electron impact mass spectrometry (LC—EI-MS) to assess the use of LC—MS methods for the determination of these compounds in biological materials. LC—TSP mass spectra showed a single [M + 1]+ ion with no fragmentation; LC—EI mass spectra showed fragment ions which were similar in mass and relative intensities to those obtained by conventional EI-MS. These data should serve as a basis for the development of LC—MS methods for the qualitative and quantitative analysis of coumarin anticoagulants in biological samples. LC—TSP-MS was applied to the determination of phenprocoumon in a plasma extract from an anticoagulated patient.  相似文献   

18.
The validation of a high-performance liquid chromatographic method for the simultaneous determination of low level cotinine and 3-hydroxycotinine in human saliva is reported. Analytes and deuterated internal standards were extracted from saliva samples using automated solid-phase extraction, the columns containing a hyper cross-linked styrene–divinylbenzene copolymer sorbent, and analysed by reversed-phase liquid chromatography with tandem mass spectrometric detection (LC–MS–MS). Lower limits of quantitation of 0.05 and 0.10 ng/ml for cotinine and 3-hydroxycotinine, respectively, were achieved. Intra- and inter-batch precision and accuracy values fell within ±17% for all quality control samples, with the exception of quality control samples prepared at 0.30 ng/ml for 3-hydroxycotinine (inter-day precision 21.1%). Results from the analysis of saliva samples using this assay were consistent with subjects’ self-reported environmental tobacco smoke (ETS) exposures, enhancing the applicability of cotinine as a biomarker for the assessment of low level ETS exposure.  相似文献   

19.
A capillary gas chromatography–mass spectrometric (GC–MS) method in human urine has been developed and validated for the quantitative determination of dicarboxylic acids (dioic acids) which are produced in the body as a consequence of the administration of an inhibitor of the enzyme squalene synthase, which is involved in the biosynthesis of cholesterol. The standards and quality control (QC) samples were prepared by adding dioic acids into human urine. Internal standard (sebacic acid) was added to each urine sample (0.1 ml) and then dried by evaporation under nitrogen. The dried sample was reacted with pentafluorobenzyl (PFB) bromide under conditions that maximized the formation of the di-PFB ester (at the expense of the mono-PFB ester) of the dioic acids. After drying by evaporation, each sample residue was reconstituted in mesitylene and injected into a capillary GC–MS system via a splitless injection. The detection was by negative ion chemical ionization mass spectrometry with selected ion monitoring (SIM) of the [M−PFB] of the analytes and the internal standard.  相似文献   

20.
A sensitive, specific, accurate and reproducible analytical method employing a divalent cation chelating agent (disodium EDTA) for sample treatment was developed to quantitate reserpine in FVB/N mouse plasma. Samples pretreated with 40 μl of 2% disodium EDTA in water were extracted by a semi-automated 96-well liquid–liquid extraction (LLE) procedure to isolate reserpine and a structural analog internal standard (I.S.), rescinnamine, from mouse plasma. The extracts were analyzed by turbo ionspray liquid chromatography–tandem mass spectrometry (LC–MS–MS) in the positive ion mode. Sample preparation time for conventional LLE was dramatically reduced by the semi-automated 96-well LLE approach. The assay demonstrated a lower limit of quantitation of 0.02 ng/ml using 0.1-ml plasma sample aliquots. The calibration curves were linear from 0.02 to 10 ng/ml for reserpine. The intra- and inter-assay precision of quality control (QC) samples ranged from 1.75 to 10.9% for reserpine. The intra- and inter-assay accuracy of QC samples ranged from −8.17 to 8.61%. Reserpine and the I.S. were found to be highly bound to FVB/N mouse plasma protein. This is the first report of disodium EDTA employed as a special protein-bound release agent to recover protein-bound analytes from plasma. These matrix effects and the effects of pH in the HPLC mobile phase on the sensitivities of LC–MS–MS are discussed in this paper.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号