首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
We report here a quantitative method for the analysis of sirolimus in blood using solid-phase sample preparation and HPLC–electrospray-tandem mass spectrometry detection. Blood samples (500 μl) were prepared by pre-treatment with acetonitrile: 15 mM zinc sulphate (70:30, v/v), containing 32-demethoxysirolimus (internal standard) and C18 solid-phase extraction. The electrospray conditions were chosen to enhance the [M+NH4]+ species at the expense of other species. Detection was by multiple reactant monitoring with the mass transitions m/z 931.8→864.6 and m/z 901.8→834.4 employed for sirolimus and the internal standard, respectively. The method was linear over the range 0.2 to 100.0 μg l−1. The accuracy and inter-day precision, over this concentration range, was 94.4% to 104.4% and 1.4% to 5.0%, respectively. The accuracy and total precision at the limit of quantitation (0.2 μg l−1) was 103.0% and 10.8%, respectively. The mean absolute recovery of sirolimus and the internal standard were 80.5% and 81.3%, respectively. The sensitivity and analytical concentration range of the method make it suitable for therapeutic drug monitoring and pharmacokinetic studies. Further, the ability of the method to measure parent drug specifically will facilitate the evaluation of immunoassays for sirolimus.  相似文献   

2.
A simple, accurate and sensitive high-performance liquid chromatographic method was developed for the determination of propofol, an intravenous anaesthetic agent, in rat whole blood or plasma samples. The method is based on precipitation of the protein in the biological fluid sample and direct injection of the supernatant into an HPLC system involving a C18 reversed-phase column using a methanol-water (70:30) mobile phase delivered at 1 ml/min. Propofol and the internal standard (4-tert.-octylphenol) were quantified using a fluorescence detector set at 276 nm (excitation) and 310 nm (emission). The analyte and internal standard had retention times of 6.3 and 10.5 min, respectively. The limit of quantification for propofol was 50 ng/ml using 100 μl of whole blood or plasma sample. Calibration curves were linear (r2=0.99) over a 1–10 μg/ml concentration range and intra- and inter-day precision were between 4–11%. The assay was applied to the determination of propofol whole blood pharmacokinetics and propofol whole blood to plasma distribution ratios in rats.  相似文献   

3.
A selective assay of flunitrazepam (F) and its metabolites 7-aminoflunitrazepam (7-AF), N-desmethylflunitrazepam (N-DF) and 3-hydroxyflunitrazepam (3-OHF) with liquid chromatography–atmospheric pressure chemical ionization mass spectrometry (LC–APCI-MS, positive ions) is described. The drugs were isolated from serum, blood or urine using a solid-phase extraction procedure previously applied to various drugs of abuse. F-d3 and 7-AF-d3 were used as internal standards. The drugs were separated on ODS column in acetonitrile–50 mM ammonium formate buffer, pH 3.0 (45:55, v/v). After analysis of mass spectra taken in full scan mode, a selected-ion monitoring detection was applied with following ions: m/z 284 (7-AF and F), 287 (7-AF-d3 and F-d3), 314 (F), 300 (N-DF and 3-OHF), 317 (F-d3), 330 (3-OHF). The limits of detection were: 0.2 μg/l for F and 7-AF, 1 μg/l for N-DF and 3-OHF. The method was linear in the range 1–500 μg/l, the recoveries ranged from 92 to 99%. The method was applied for determination of F and metabolites in clinical and forensic samples. LC–APCI-MS seems to be a method of choice for these compounds.  相似文献   

4.
Nelfinavir mesylate, a potent and orally bioavailable inhibitor of HIV-1 protease (Ki=2 nM), has undergone Phase III clinical evaluation in a large population of HIV-positive patients. A high-performance liquid chromatography analytical method was developed to determine the pharmacokinetic parameters of the free base, nelfinavir, in these human subjects. The method involved the extraction of nelfinavir and an internal standard, 6,7-dimethyl-2,3-di-(2-pyridyl)quinoxaline, from 250 μl of human plasma with a mixture of ethyl acetate–acetonitrile (90:10, v/v). The analysis was via ultraviolet detection at 220 nm using a reversed-phase C18 analytical column and a mobile phase consisting of 25 mM monobasic sodium phosphate buffer (adjusted to pH 3.4 with phosphoric acid)–acetonitrile (58:42, v/v) that resolved the drug and internal standard peaks from non-specific substances in human plasma. The method was validated under Good Laboratory Practice (GLP) conditions for specificity, inter- and intra-assay precision and accuracy, absolute recovery and stability. The mean recovery ranged from 92.4 to 83.0% for nelfinavir and was 95.7% for the internal standard. The method was linear over a concentration range of 0.0300 μg/ml to 10 μg/ml, with a minimum quantifiable level of 0.0500 μg/ml for nelfinavir.  相似文献   

5.
A column-switching high-performance liquid chromatography method with ultraviolet detection at 210 nm has been developed for the determination of N-(trans-4-isopropylcyclohexylcarbonyl)-d-phenylalanine (AY4166, I) in human plasma. Plasma samples were prepared by solid-phase extraction with Sep-Pak Light tC18, followed by HPLC. The calibration graph for I was linear in the range 0.1–20 μg/ml. The limit of quantitation of I, in plasma, was 0.05 μg/ml. The recovery of spiked I (0.5 μg/ml) to drug-free plasma was over 92% and the relative standard deviation of spiked I (0.5 μg/ml) compared to drug-free plasma was 4.3% (n = 8).  相似文献   

6.
The aim of this study was to describe an high-performance liquid chromatographic assay for the simultaneous determination of two HIV protease inhibitors, saquinavir and ritonavir, in human serum. The method involved extraction of ritonavir and saquinavir from serum with the aid of solid-phase extraction C18 cartridges followed by high-performance liquid chromatography with a C8 column and ultraviolet detection set at a wavelength of 240 nm. The assay was linear and has been validated over the concentrations range of 0.5–32 μg/ml for ritonavir and 0.075–4.8 μg/ml for saquinavir, from 600 μl serum extracted. In future, the assay will be used to support human population pharmacokinetic studies, and therapeutic drug monitoring for ritonavir and saquinavir.  相似文献   

7.
This study reports a sensitive analytical method suitable for the quantitative analysis of ethylenethiourea (ETU) in human urine and its application to samples from the general population. Sample preparation involved the use of diatomaceous earth extraction columns to remove matrix interferences. Quantification was achieved by liquid chromatography–mass spectrometry using positive ion atmospheric pressure chemical ionisation. Within-day and between-day variability of 14% (n = 10) and 11% (n = 6), respectively, were obtained at 98 nmol/l (10 μg l−1). The assay was linear over the investigated range 2.5–245 nmol/l, with a limit of detection of 2.5 nmol/l. The method was applied to monitoring background levels of ETU in urine samples from the general population in the UK. Results obtained from 361 spot samples contained ETU levels ranging from less than the detection limit (54% of samples) to a maximum of 15.8 μmol/mol creatinine (14.3 μg/g creatinine). The 95th percentile was 5.7 μmol/mol creatinine (5.2 μg/g creatinine).  相似文献   

8.
A sensitive and selective method for the quantification of mycophenolate mofetil and its active metabolite mycophenolic acid in different human skin layers after dermal administration is presented. The skin layers were separated after in vitro penetration experiments and a methanolic extraction was performed. Positive ion electrospray HPLC–MS in selected ion monitoring mode was used to quantify the substances after isocratic separation by a C18 analytical column. The minimum detectable concentrations were 850 pg/ml for MMF and 1 ng/ml for MPA. The peak areas depended linearly on the concentration of both drugs over the range of 25–1000 ng/ml (r2≥0.996) with accuracy ≤9.8% and precision ≤13.2%. Total imprecision at quantification limits was 15.2% at 10 ng/ml and 16.3% at 1500 ng/ml for MMF and 15.1% at 21.0 ng/ml and 17.5% at 1300 ng/ml for MPA. This HPLC–MS method will be applicable to the profiling of MMF amounts in skin and its conversion to MPA after application of different formulations.  相似文献   

9.
10.
A reliable reversed-phase high-performance liquid chromatographic method has been developed for the determination of bromocriptine (BCT) in plasma and eye tissues. The BCT and propranolol, added as an internal standard (I.S.), were extracted by a liquid–liquid technique followed by an aqueous back-extraction, allowing injection of an aqueous solvent into a 4-μm Nova-Pak C18 column (150×3.9 mm I.D.). The mobile phase was a mixture of 30 parts of acetonitrile and 70 parts of 0.2% triethylamine (pH 3) at a flow-rate of 1 ml/min. Fluorescence detection was at an excitation wavelength of 330 nm and an emission wavelength of 405 nm. The retention times of I.S. and BCT were 4.1 and 11.6 min, respectively. The calibration curve was linear over the concentration range 0.2–10 μg/l for plasma (r>0.999) and vitreous humour (r>0.997) and 1–50 μg/l for aqueous humour (r>0.985). The limit of quantification was 0.2 μg/l for plasma and vitreous humour using a 1-ml sample and was 1 μg/l for aqueous humour using a 0.2-ml sample. The quality control samples were reproducible with acceptable accuracy and precision. The within-day recovery (n=3) was 100–102% for plasma, 91–106% for aqueous humour and 96–111% for vitreous humour. The between-day recovery (n=9) was 90–114% for plasma, 83–115% for aqueous humour and 90–105% for vitreous humour. The within-day precision (n=3) and the between-day precision (n=9) were 1.7–7.0% and 8.1–13.6%, respectively. No interferences from endogenous substances were observed. Taken together, the above simple, sensitive and reproducible high-performance liquid chromatography assay method was suitable for the determination of BCT in plasma and eye tissues following ocular application of BCT for the therapy of myopia.  相似文献   

11.
To face the problem of simultaneous isolation and quantitation of isotopically labeled amino acids in biological samples, two semi-preparative chromatographic methods were developed. One method was especially designed to isolate radioactively labeled amino acids for which we used derivatization with the fluorophore o-phtaaldialdehyde (OPA), which is known to be easy and reliable. Isolation of amino acids labeled with stable isotopes required another approach as we wanted to use isotope ratio mass spectroscopy (IRMS), which can only be performed on pure, non-derivatized amino acids. Becuase the OPA probe cannot be removed after isolation of the derivative, we used 9-fluorenylmethylchloroformate (FMOC) instead. This probe is linked to an amino acid via a peptide bond which can easily be broken byb gas-phase acid hydrolysis (103% recovery after 5 h at 150°C: S.D = 3.5%, n = 14). Run time (injection to injection) was 60 min for the OPA method and 75 min for the FMOC method. Both fluorescence and UV absorbance detection can be employed. The coefficient of variation (C.V.) for peak area measurement was below 2% for most OPA amino acids and below 3% for most FMOC amino acids. At maximum, a total of 1000 μl could be injcted, representing approximately 200 μl of deproteinized plasma. The methods were linear up to injection of 0.5 μmol of all amino acids (OPA: r2=0.995−0.999; FMOC: r2=0.992−0.999). The C.V. of the IRMS measurement within the range which can be isolated maximally in one chromatographic run (50–500 nmol), was less than 3% above 100 mmol, indicating that chromatographic isolation fulfils the needs of the IRMS determination. The resulting methods are suitable for the isolation and quantitation of micromolar amounts of labeled amino acids from biological samples.  相似文献   

12.
A high-performance liquid chromatography (HPLC) analytical method for the determination of oxolinic acid and flumequine in Artemia nauplii is described. The samples were extracted and cleaned up by a solid-phase extraction (SPE) procedure using SPE C18 cartridges. Oxolinic acid and flumequine were determined by reversed-phase HPLC using a mobile phase of methanol–0.1 M phosphate buffer, pH 3 (45:55, v/v) and a UV detection wavelength of 254 nm. Calibration curves were linear for oxolinic acid in the range of 0.2–50 μg/g (r2=0.9998) and for flumequine in the range of 0.3–50 μg/g (r2=0.9994). Mean recoveries amounted to 100.8% and 98.4% for oxolinic acid and flumequine, respectively. The quantification limit was 0.2 μg/g for oxolinic acid and 0.3 μg/g for flumequine. Quantitative data from an in vivo feeding study indicated excellent uptake of both drugs by Artemia nauplii.  相似文献   

13.
A simple, rapid and reproducible high-performance liquid chromatographic assay for cisapride and norcisapride in human plasma is described. Samples of plasma (150 μl) were extracted using a C18 solid-phase cartridge. Regenerated tubes were eluted with 1.0 ml of methanol, dried, redissolved in 150 μl of methanol and injected. Chromatography was performed at room temperature by pumping acetonitrile–methanol–0.015 M phosphate buffer pH 2.2–2.3 (680:194:126, v/v/v) at 0.8 ml/min through a C18 reversed-phase column. Cisapride, norcisapride and internal standard were detected by absorbance at 276 nm and were eluted at 4.3, 5.3 and 8.1 min, respectively. Calibration plots in plasma were linear (r>0.998) from 10 to 150 ng/ml. Intraday precisions for cisapride and norcisapride were 3.3% and 5.4%, respectively. Interday precisions for cisapride and norcisapride were 9.6% and 9.0%, respectively. Drugs used which might be coadministered were tested for interference.  相似文献   

14.
Camalexin is a phytoalexin of Arabidopsis thaliana and an important component of inducible defenses. Accurate quantification of low concentrations suffers from interference by structurally related metabolites. A. thaliana plants were induced with silver nitrate and camalexin was extracted using methanol and identified and quantified by (i) TLC as a blue fluorescent band, (ii) microtiter plate-based fluorescence spectroscopy, (iii) GC on a midpolar column coupled to flame ionization detection, (iv) C18 HPLC coupled to a photodiode detector, and (v) UPLC coupled to a mass spectrometer detector. Standard curves over the range of 0.1–15 μg ml−1 gave R2 values from 0.996 to 0.999. The different methods were compared and evaluated for their ability to detect and quantify increasing concentrations (<0.4–8 μg g−1 FW) of camalexin. Each of the techniques presented advantages and disadvantages with regard to accuracy, precision, interference, analytical sensitivity, and limits of detection. TLC is a good qualitative technique for the identification of camalexin and fluorescence spectroscopy is subject to quenching when performed on crude extracts. Comparable results were obtained with GC–FID, HPLC–PDA, and UPLC–MS, with UPLC–MS having the added advantage of short analysis times and detection based on accurate mass.  相似文献   

15.
A method was developed for the determination in human urine of S-phenylmercapturic (PMA) and S-benzylmercapturic (BMA) acids, metabolites respectively of benzene and toluene. PMA and BMA were determined, after alkaline hydrolysis, to give respectively thiophenol and benzylmercaptan, and coupling of the thiol-containing compounds with monobromobimane (MB), by reversed-phase HPLC on a diphenyl-silica bonded cartridge (100×4.6 mm I.D., 5 μm particle size) with fluorimetric detection. Wavelengths for excitation and emission were 375 and 480 nm, respectively. The recovery of PMA and BMA from spiked urines was >90% in the 10–500 μg/l range; the quantification limits were respectively 1 and 0.5 μg/l; day-to-day precision at 42 μg/l was C.V. <7%. The suitability of the proposed procedure for the biological monitoring of exposure to low-level airborne concentrations of benzene and toluene, was evaluated by analyzing the urinary excretion of PMA and BMA in subjects exposed to different sources of aromatic hydrocarbons, namely occupationally-unexposed referents (non-smokers, n=15; moderate smokers, n=8; mean number of cigarettes smoked PER-DAY=17 cig/day) and non-smoker workers occupationally exposed to toluene in maintenance operations of rotogravure machines (non-smokers, n=17). Among referents, non-smokers showed values of PMA ranging from <1 to 4.6 μg/l and BMA from 1.0 to 10.4 μg/l; in smokers, PMA values ranging from 1.2 to 6.7 μg/l and BMA from 9.3 to 39.9 μg/l, were observed. In occupationally exposed non-smoker subjects, BMA median excretion value (23.6 μg/l) was higher than in non-smoker referents (3.5 μg/l) (P<0.001) and individual BMA values (y, μg/l) were associated and increased with airborne toluene concentration (x, mg/m3) according to the equation y=6.5+0.65x (r=0.69, P<0.01, n=17). The proposed analytical method appears to be a sensitive and specific tool for biological monitoring of low-level exposure to benzene and toluene mixtures in occupational and environmental toxicology laboratory.  相似文献   

16.
A previously published method was used for the determination of piroxicam in plasma samples obtained from rat. The sample preparation involved liquid extraction, centrifugation and evaporation. Separation of piroxicam from internal standard occurred on a reversed-phase C18 column with a mobile phase consisting of methanol-phosphate buffer pH 2 (45:55). The detection limit of the assay was 0.02–20 μg/ml. The assay linearity was good (typically r = 0.9992). The method was applied for determination of piroxicam in rats after administration of an oral dose of 2 mg/kg piroxicam.  相似文献   

17.
18.
A method to determine plasma concentrations of ciprofloxacin and its metabolite desethyleneciprofloxacin (M1) by CE with HeCd laser-induced fluorescence detection is described. Following precipitation of proteins and centrifugation supernatant is injected hydrodynamically (10 s, 0.5 p.s.i.) into the capillary. Overall analysis time for the quantification of both analytes was 7 min. The total amount of plasma needed for multiple injections (n>5) was 10–20 μl. Data on accuracy and precision are presented. The assay performance is compared to the specifications of a validated HPLC method, which is routinely used for the quantification of ciprofloxacin and M1 in body fluids. Both methods showed comparable accuracy and precision for both analytes throughout the whole working range (inter-day precision <9%; inter-day accuracy 96–110%). The limit of quantification (LOQ) of 20 μg/l (M1 10 μg/l) for the CE procedure was slightly higher than for the HPLC method, where 10 μg/l (M1 2.5 μg/l) was determined. However, application of the methods to human plasma samples derived from a clinical study proved that comparable results are obtained and that the sensivity of the HPCE method was sufficient to fully describe typical plasma concentration timie profiles of ciprofloxacin and its metabolite M1. Both the adequate sensitivity and the required smaller sample volume compared to HPLC indicate that the method is feasible for clinical studies where sample amounts are limited, e.g., studies to investigate pharmacokinetics in pediatric patients. Preclinical studies form another possible application of this technique.  相似文献   

19.
A simple method for the determination of oxysterols was developed by semi-micro high-performance liquid chromatography with electrochemical detection (semi-micro HPLC–ECD). Semi-micro HPLC–ECD was established using a C30 microbore column, acetonitrile containing 50 mmol/L LiClO4 as a mobile phase, and an applied potential at +2.8 V versus Ag/AgCl. The current peak height was linearly related to the amount of sterol injected from 12.5 to 250 pmol (r > 0.999) with a relative standard deviation (RSD) of less than 2.9% (n = 6). This method was applied to the determination of seven oxysterols in oxidatively modified low-density lipoprotein (Ox–LDL). Oxysterols were determined with a recovery of more than 78.0% and an RSD of less than 2.9% (n = 6) except for 7-ketocholesterol. 7-Ketocholesterol was determined as a sum of intact 7-ketocholesterol and its degradation product on saponification, cholesta-3,5-dien-7-one, with a recovery of 98.0% and an RSD of 2.5% (n = 6). From these results, the current method enabled the simultaneous determination of seven oxysterols without any derivatization, providing a useful tool for the assessment of oxysterol contents in Ox–LDL.  相似文献   

20.
A method for the quantitative analysis of cudratricusxanthone B (CXB) in rat plasma by high performance liquid chromatography–electrospray ionization-tandem mass spectrometry (HPLC–ESI-MS/MS) has been developed and validated. The method involved liquid–liquid extraction from plasma, simple chromatographic conditions on a Venusil XBP-PH C18 column with the mobile phase of 0.5% formic acid in methanol, and mass spectrometric detection using an API-3000 instrument. Multiple reaction monitoring (MRM) mode was used to monitor precursor/product ion transitions of m/z 397.1/285.0 for CXB and m/z 381.6/269.2 for the internal standard (I.S.) cudraxanthone H. The standard curves were linear over the concentration range of 1–500 ng/mL for CXB in rat plasma. The intra- and inter-batch accuracy for CXB at four concentrations was 89.4–99.5% and 89.4–100.8%, respectively. The RSDs were less than 7.92%. The lower limit of quantification for CXB was 1.0 ng/mL using 100 μL of plasma. The average extraction recoveries of CXB ranged from 80.1 to 95.4% at the concentrations of 2, 50 and 500 ng/mL, respectively. This method was successfully applied to the pharmacokinetic study after an intravenous administration of CXB in male Sprague–Dawley (SD) rats.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号