首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A fully automated chromatographic method including on-line blood serum or plasma clean-up, isocratic high-performance liquid chromatography (HPLC) and spectrophotometric detection was developed for quantitative analysis of the new antipsychotic drug amisulpride. After injection of serum or plasma onto the HPLC system and clean-up on a pre-column (10x4.0 mm I.D.) filled with Silica CN 20 micrometer (pore size 10 nm) by an eluent consisting of 8% acetonitrile in deionized water, the chromatographic separation was performed on Lichrospher CN (5 micrometer; 250x4.6 mm I.D.) by an eluent consisting of 50% acetonitrile and 50% aqueous potassium phosphate buffer (0.008 M, pH 6.4). The UV detector was set at 254 nm. The limit of quantification was about 10 microgram/l. The method revealed linearity between 10 and 600 microgram/l (correlation coefficients R(2)>0.9996). The inter-assay reproducibility (coefficient of variation) of quality control samples was between 2.8 and 11.3%. Inaccuracy was between -0.6 and +9.1%. The performance of daily calibration standards revealed an imprecision always below 15% and maximum inaccuracy of 7.7%. The method can be applied to therapeutic drug monitoring as well as pharmacokinetic studies of amisulpride.  相似文献   

2.
A rapid high-performance liquid chromatography (HPLC) method was developed for determination of metformin, an oral antidiabetic agent, in plasma. Sample preparation entailed a 30-min centrifugation of plasma through a micron filter with direct injection of the protein-free ultrafiltrate into an HPLC system consisting of a cation-exchange extraction column (7.5×4.6 mm), a column switching valve, and a cation-exchange analytical column (250×4.6 mm). The eluent was monitored at 232 nm. Metformin was well resolved at a retention time of about 5 min. There was less than 2% loss of metformin during ultrafiltration and good linearity was established from 0.10 to 40 mg/l of metformin hydrochloride. The lower limit of quantitation was about 0.05 mg/l, at which concentration the signal-to-noise was above 10. The intra- and inter-assay coefficients of variation at plasma concentrations of metformin hydrochloride between 0.25 and 25 mg/l were typically 0.8–1.4% and 3.5–6.4%, respectively. This method offers a rapid sample preparation time and achieves excellent sensitivity without resorting to extraction and evaporation techniques.  相似文献   

3.
An isocratic high-performance liquid chromatographic (HPLC) method with UV absorbance detection is described for the quantification of clozapine (8-chloro-11-(4′-methyl)piperazino-5H-dibenzo[b,e]-1,4-diazepine) and its two major metabolites in plasma and red blood cells (RBCs). The method involves sample clean-up by liquid-liquid extraction with ethyl acetate. The organic phase was back-extracted with 0.1 M hydrochloric acid. Loxapine served as the internal standard. The analytes were separated by HPLC on a Kromasil Ultrabas C18 analytical column (5 μm particle size; 250×4.6 mm I.D.) using acetonitrile-phosphate buffer pH 7.0 (48:52, v/v) as eluent and were measured by UV absorbance detection at 254 nm. The limits of quantification were 20 ng/ml for clozapine and N-desmethylclozapine and 30 ng/ml for clozapine N-oxide. Recovery from plasma or RBCs proved to be higher than 62%. Precision, expressed as % C.V., was in the range 0.6–15%. Accuracy ranged from 96 to 105%. The method's ability to quantify clozapine and two major metabolites simultaneously with precision, accuracy and sensitivity makes it useful in therapeutic drug monitoring.  相似文献   

4.
We established a method for automated quantitative analysis of (es-)citalopram and desmethyl(es-)citalopram in serum using column-switching high performance liquid chromatography (HPLC). For sample clean-up serum was injected onto a LiChrospher CN 20 microm precolumn using 8% acetonitrile in deionized water. Drugs were eluted by back-flush flow onto the analytical column (LiChrospher CN 5 microm) at a flow rate of 1.5 ml/min with phosphate buffer 8 mmol/l pH 6.4/acetonitrile (50/50, v/v). Haloperidol was used as internal standard. Analytes were detected by ultraviolet spectrophotometry at 210 nm. Detection limit of (es-)citalopram was 6 ng/ml. The method was found to be suitable for therapeutic drug monitoring of patients treated with citalopram or escitalopram.  相似文献   

5.
Reversed-phase HPLC methods are described for determining the stability and concentration certification of the antituberculosis prodrug aconiazide (ACON) in aqueous dosing solution and for assessing the concentrations of ACON and isoniazid (INH) in plasma from ACON-treated male and female Fischer-344 rats. ACON was analyzed in plasma by direct injection; it was separated on a 250 × 4.6 mm I.D. 5 μm C18 column using a 40% aqueous methanol mobile phase containing 5 g/l ammonium formate, and detected at 313 nm. INH was determined in the plasma of treated rats after a two-step precipitation of plasma proteins; it was separated on a 250 mm × 4.6 mm I.D. 5 μm CN column, eluted with 5% aqueous isopropanol containing 5 g/l ammonium formate, and detected with an electrochemical detector at +0.8 V. These methods allow a simple, rapid, and reliable determination of ACON and INH in plasma down to 0.1 μg/ml.  相似文献   

6.
A simple, sensitive and reproducible method was developed for the determination of lamotrigine in whole blood with on-line solid phase extraction followed by HPLC separation with UV detection. Whole blood samples were diluted 1:1 with water and then injected directly on a clean-up column dry-packed with 40microm C8 silica and separated on a C18 reversed-phase column (150x4.6mm) at room temperature. The extraction column was activated with methanol and conditioned with phosphate buffer of pH 4.5. Mobile phases consisted of phosphate buffer of pH 4.5 for the extraction column and of phosphate buffer of pH 4.5 - acetonitrile (60:40, v/v) for the analytical column. At a flow rate of 1.0ml/min and a connection time of 1.0min, the complete cycle time was 10.0min. Detection was carried out at 260nm. No internal standard was necessary. The method was linear over concentration range 0.2-20.0microg/ml for lamotrigine. Recovery was 98%. Within-day and between-day coefficients of variation ranged from 1.8 to 6.7%.  相似文献   

7.
A high-performance liquid chromatography (HPLC) method was developed for quantification of both isomers of the thioxanthene neuroleptic flupentixol and of the butyrophenone derivative haloperidol in human serum. After extraction with diethyl ether–n-heptane (50:50, v/v), an isocratic normal-phase HPLC system with a Hypersil cyanopropyl silica column (250×4.6 mm, 5 μm particle size) was used with ultraviolet detection at 254 nm and elution with a mixture of 920 ml acetonitrile, 110 ml methanol, 30 ml 0.1 M ammonium acetate, and 50 μl triethylamine. The limit of quantitation of 0.5 ng/ml and 0.3 ng/ml for flupentixol and haloperidol, respectively, was sufficient to quantify both compounds in serum after administration of clinically adjusted doses. The suitability of the described method for therapeutic drug monitoring and clinical pharmacokinetic studies was assessed by analysis of more than 100 trough level serum samples.  相似文献   

8.
A simple, rapid, and accurate column-switching liquid chromatography method was developed and validated for direct and simultaneous analysis of loxoprofen and its metabolites (trans- and cis-alcohol metabolites) in human serum. After direct serum injection into the system, deproteinization and trace enrichment occurred on a Shim-pack MAYI-ODS pretreatment column (10 mm x 4.6 mm i.d.) by an eluent consisting of 20 mM phosphate buffer (pH 6.9)/acetonitrile (95/5, v/v) and 0.1% formic acid. The drug trapped by the pretreatment column was introduced to the Shim-pack VP-ODS analytical column (150 mm x 4.6 mm i.d.) using acetonitrile/water (45/55, v/v) containing 0.1% formic acid when the 6-port valve status was switched. Ketoprofen was used as the internal standard. The analysis was monitored on a UV detector at 225 nm. The chromatograms showed good resolution, sensitivity, and no interference by human serum. Coefficients of variations (CV%) and recoveries for loxoprofen and its metabolites were below 15 and over 95%, respectively, in the concentration range of 0.1-20 microg/ml. With UV detection, the limit of quantitation was 0.1 microg/ml, and good linearity (r = 0.999) was observed for all the compounds with 50 microl serum samples. The mean absolute recoveries of loxoprofen, trans- and cis-alcohol for human serum were 89.6 +/- 3.9, 93.5 +/- 3.2, and 93.7 +/- 4.3%, respectively. Stability studies showed that loxoprofen and its metabolites in human serum were stable during storage and the assay procedure. This analytical method showed excellent sensitivity with small sample volume (50 microl), good precision, accuracy, and speed (total analytical time 18 min), without any loss in chromatographic efficiency. This method was successfully applied to the pharmacokinetic study of loxoprofen in human volunteers following a single oral administration of loxoprofen sodium (60 mg, anhydrate) tablet.  相似文献   

9.
An automated HPLC method with column switching is described for the determination of quetiapine, clozapine, perazine, olanzapine and metabolites in blood serum. After clean-up on silica C8 material (20 microm particle size) drugs were separated on ODS Hypersil C18 material (5 microm; column size 250 mm x 4.6 mm i.d.) within 25 min and quantified by ultraviolet (UV) detection at 254 nm. The limit of quantification ranged between 10 and 50 ng/ml. At therapeutic concentrations of the drugs, the inter-assay reproducibility was below 10%. Analyses of drug concentrations in serum of 75-295 patients treated with therapeutic doses of the antipsychotic drugs revealed mean+/-S.D. steady state concentrations of 139+/-136 ng/ml for quetiapine, 328+/-195 ng/ml for clozapine, 48+/-27 ng/ml for olanzapine and 71+/-52 ng/ml for perazine. The method was thus suitable for routine therapeutic drug monitoring and may be extended to other drugs.  相似文献   

10.
A column-switching, reversed-phase high-performance liquid chromatographic (HPLC) method for the determination of a new carbapenem antibiotic assay using ultraviolet detection has been developed for a new carbapenem antibiotic L-749,345 in human plasma and urine. A plasma sample is centrifuged and then injected onto an extraction column using 25 mM phosphate buffer, pH 6.5. After 3 min, using a column-switching valve, the analyte is back-flushed with 10.5% methanol–phosphate buffer for 3 min onto a Hypersil 5 μm C18 BDS 100×4.6 mm analytical column and then detected by absorbance at 300 nm. The sample preparation and HPLC conditions for the urine assay are similar, except for a longer analytical column 150×4.6 mm. The plasma assay is specific and linear from 0.125 to 50 μg/ml; the urine assay is linear from 1.25 to 100 μg/ml.  相似文献   

11.
A gradient eluent HPLC analysis in human plasma and urine was developed and validated for methylprednisolone (MP), its prodrug methylprednisolone-21-hemisuccinate (MPS) with the metabolites 6β-hydroxy-6α-methylprednisolone (MPA), 20-hydroxymethylprednisolone (MPC), 6β-hydroxy-20α-hydroxymethylprednisolone (MPB), 6β-hydroxy-20β-hydroxymethylprednisolone (MPE), 20-carboxymethylprednisolone (MPD), methylprednisolone-glucuronide (MPF) and 21-carboxymethylprednisolone (MPX). The column was Cp Spherisorb C8 5 μm, 250 mm×4.6 mm I.D. (Chrompack, Bergen op Zoom, The Netherlands) with a guard column 75 mm×2.1 mm, packed with pellicular reversed-phase. The eluent was a mixture of acetonitrile and 0.067 M KH2PO4 buffer, pH 4.5. At t=0, the eluent consisted of 2% acetonitrile and 98% buffer (v/v). Over the following 35 min the eluent changed linearly until it attained a composition of 50% acetonitrile and 50% buffer (v/v). At 37 min (t=37) the eluent was changed over 5 min to the initial composition, followed by equilibration over 3 min. The flow-rate was 1.5 ml/min and UV detection was achieved at 248 nm. Preliminary pharmacokinetic data were obtained from one patient who showed illustrative plasma concentration–time curves and renal excretion-time profiles after a short-lasting infusion (0.5 h) of 1 g of methylprednisolone hemisuccinate. The half-life of prodrug methylprednisolone-21-hemisuccinate (MPS) was 0.3 h, that of metabolite MPX (21-carboxy MP) was 0.4 h and that of the parent drug methylprednisolone (MP) was 1.4 h. The half-lives of the metabolites are almost similar (4 h). The main compounds in the urine are methylprednisolone hemisuccinate (prodrug, 15.0%), methylprednisolone (parent drug, 14.6%), metabolite MPD (20-carboxy, 11.7%), and metabolite MPB (13.2%). The renal clearance values of metabolites MPB, MPC and MPD are approximately 500 ml/min, that of MP is 100 ml/min.  相似文献   

12.
Studies investigating the relationship between CYP2C19 genotype and the stereoselective metabolism of omeprazole have not been reported. In the present study, we developed a simple and sensitive analytical method based on column switching reversed phase high-performance liquid chromatography (HPLC) with UV detection to determine the concentrations of (R)- and (S)-omeprazole and of its principal metabolites, (R)- and (S)-5-hydroxyomeprazole, and the non-chiral, omeprazole sulfone, in human plasma. Sample preparation involved liquid-liquid extraction with diethyl ether:dichloromethane (60:40, v/v) followed by clean-up on a TSK BSA-ODS/S column (5 μm, 10 mm × 4.6mm i.d.) using phosphate buffer:acetonitrile (97:3, v/v, pH 6.4). After column switching, separation was performed on a Shiseido CD-ph chiral column (5 μm, 150 mm × 4.6mm i.d.) using phosphate buffer:methanol (45:55, v/v, pH 5.0) as mobile phase. The limit of quantitation (LOQ) was 5 ng/mL for all analytes with intra- and inter-day precisions (as coefficient of variation) of <9.5% and <9.6%, respectively for all analytes. The present method was successfully applied to a chiral pharmacokinetic study of omeprazole in human volunteers with different CYP2C19 genotypes. The results show that the formation of (R)-5-hydroxyomeprazole gives the best correlation with CYP2C19 genotype.  相似文献   

13.
A simple and sensitive column-switching HPLC method was developed for the simultaneous determination of two furocoumarin compounds, byak-angelicin and oxypeucedanin hydrate, which are the main components of hot water extract of Angelica dahurica root (AE), in rat plasma. Plasma sample was simply deproteinated with perchloric acid. After centrifugation, the supernatant was injected into a column-switching HPLC system consisting of a clean-up column (Symmetry Shield RP 8, 20×3.9 mm I.D.) and analytical column (Symmetry C18, 75×4.6 mm I.D.) which were connected with a six-port switching valve. The flow-rate of the mobile phase (acetonitrile–water, 20:80) was maintained at 1 ml/min. Detection was carried out at wavelength 260 nm with a UV detector. The column temperature was maintained at 40°C. The calibration curves of byak-angelicin and oxypeucedanin hydrate were linear over the ranges 19.6 to 980 ng/ml (r2>0.997). The accuracy of these analytes was less than 4.4%. The intra- and inter-day relative standard deviations of byak-angelicin and oxypeucedanin hydrate were within 12.0% and 12.7%, respectively. The present method was applied for the analysis of plasma concentration from rats after administration of AE.  相似文献   

14.
High-performance liquid chromatographic assay for cefepime in serum   总被引:6,自引:0,他引:6  
A simple, rapid, specific and sensitive high-performance liquid chromatographic method was developed for the determination of cefepime 1-[[6R, 7R)-7-[2-(2-amino-4-thiazolyl)glyoxylamido]-2-carboxy-8-oxo-5-thia-1-azabicyclo-[4.2.0] oct-2-en-3-yl]methyl]-1-methylpyrrolidinium hydroxide, inner salt, 72-(Z)-(O-methyloxime) in human serum. Separation was achieved on a reversed-phase Ultrasphere XL-ODS column (75×4.6 mm I.D.). The mobile phase was 7% acetonitrile in 20 mM ammonium acetate (pH 4). Cefepime eluted in the range of 1.8–2.2 min. Detection was by UV absorbance at 254 nm. The lower limit of quantitation of cefepime in plasma was 0.5 μg/ml. The average absolute recovery was 106.2±2.1%. The linear range was from 0.1 to 50 μg/ml, with a correlation coefficient greater than 0.999. The within-day C.V.s for human samples were 4.9 and 2.3% for 1 and 50 μg/ml, respectively. The between-day C.V.s for human serum samples were 14.5, 7.4 and 6.7 for 1, 25 and 50 μg/ml, respectively. Cefepime was found to be unstable in serum at room temperature. For delayed assay, samples must be stored at −80°C.  相似文献   

15.
A simple, rapid and precise HPLC method has been developed for the assay of verapamil in human plasma. The clean up of the plasma samples was tested using several adsorbents for solid-phase extraction and best recovery was obtained using mixed-mode cartridges (HLB - hydrophilic-lipophilic balance) ranging between 94.70 and 103.71%. HPLC separation was performed with isocratic elution on Lichrospher 60 RP-select B column (250 mm × 4 mm I.D., 5 μm particle size). The mobile phase was 40% acetonitrile and 0.025 mol/L KH2PO4 with pH 2.5 at flow rate of 1 mL/min. Diltiazem was used as internal standard and the detection wavelength was 200 nm. The calibration curves were linear in the range of 10–500 ng/mL. The developed method is convenient for routine analysis of verapamil in human plasma.  相似文献   

16.
A sensitive HPLC method for the quantification of praziquantel enantiomers in human serum is described. The method involves the use of a novel disc solid-phase extraction for sample clean-up prior to HPLC analysis and is also free of interference from trans-4-hydroxypraziquantel, the major metabolite of praziquantel. Chromatographic resolution of the enantiomers was performed on a reversed-phase cellulose-based chiral column (Chiralcel OJ-R) under isocratic conditions using a mobile phase consisting of 0.1 M sodium perchlorate–acetonitrile (66:34, v/v) at a flow-rate of 0.5 ml/min. Recoveries for R-(−)- and S-(+)-praziquantel enantiomers were in the range of 84–89% at 50–500 ng/ml levels. Intra-day and inter-day precisions calculated as R.S.D. were in the ranges of 3–8% and 1–8% for both enantiomers, respectively. Intra-day and inter-day accuracies calculated as percent error were in the 0.2–5% and 0.3–8% ranges for both enantiomers, respectively. Linear calibration curves were in the concentration range 10–600 ng/ml for each enantiomer in serum. The limit of quantification of each enantiomer was 10 ng/ml. The detection limit for each enantiomer in serum using a UV detector set at 210 nm was 5 ng/ml (S/N=2).  相似文献   

17.
For the quantitation of prazosin a sensitive high-performance liquid chromatographic (HPLC) method was developed. This HPLC analysis method uses an electrochemical detection technique for the identification and quantitation of prazosin. In this assay the serum samples were deproteinized by using a simple acetonitrile precipitation technique that was followed by n-hexane extraction. Prazosin in the deproteinized serum sample was separated by an isocratic elution with an ODS Hypersil HPLC column (150 × 4.6 mm) using a mobile phase consisting of 0.05 M Na2HPO4-acetonitrile (60:40), pH 8.4. Prazosin that was eluted from the column was detected using a Coulochem II electrochemical detector. The precision of this assay method was assessed by performing inter- and intra-assay by spiking prazosin free fetal bovine serum samples with 20 and 40 ng/ml concentrations of prazosin. In the intra-assay the recovery was 95.40±4.82% and 97.80±3.40%, respectively, for 20 and 40 ng/ml concentrations of prazosin that were used to spike the serum samples. This electrochemical detection HPLC assay method could be very useful in monitoring plasma levels of prazosin.  相似文献   

18.
An isocratic high-performance liquid chromatographic (HPLC) method with ultraviolet detection is described for the quantification of the atypical neuroleptic clozapine and its major metabolites, N-desmethylclozapine and clozapine N-oxide, in human serum or plasma. The method included automated solid-phase extraction on C18 reversed-phase material. Clozapine and its metabolites were separated by HPLC on a C18 ODS Hypersil analytical column (5 μm particle size; 250 mm × 4.6 mm I.D.) using an acetonitrile—water (40:60, v/v) eluent buffered with 0.4% (v/v) N,N,N′,N′-tetramethylethylenediamine and acetic acid to pH 6.5. Imipramine served as internal standard. After extraction of 1 ml of serum or plasma, as little as 5 ng/ml of clozapine and 10 or 20 ng/ml of the metabolites were detectable. Linearity was found for drug concentrations between 5 and 2000 ng/ml as indicated by correlation coefficients of 0.998 to 0.985. The intra- and inter-assay coefficients of variation ranged between 1 and 20%. Interferences with other psychotropic drugs such as benzodiazepines, antidepressants or neuroleptics were negligible. In all samples, collected from schizophrenic patients who had been treated with daily oral doses of 75–400 mg of clozapine, the drug and its major metabolite, N-desmethylclozapine, could be detected, while the concentrations of clozapine N-oxide were below 20 ng/ml in three of sixteen patients. Using the method described here, data regarding relations between therapeutic or toxic effects and drug blood levels or metabolism may be collected in clinical practice to improve the therapeutic efficacy of clozapine drug treatment.  相似文献   

19.
In this study, three fluoroquinolones, pazufloxacin, ciprofloxacin and levofloxacin, were simultaneously determined in spiked human serum by high-performance liquid chromatography (HPLC) method with fluorescence detection. Chromatography was performed using a C8 column with an isocratic mobile phase consisting of 1% triethylamine (pH 3.0)/acetonitrile (86/14, v/v). Protein precipitation was conducted using perchloric acid and methanol. The calibration curves for the three fluoroquinolones were linear over concentrations ranging from 0.1 to 20.0 μg/mL. The within-day and between-day coefficients of variation obtained from three fluoroquinolones were less than 7%, and relative errors ranged from −1.6% to 9.3%. Mean recoveries of pazufloxacin, ciprofloxacin, and levofloxacin from spiked human serum were 97%, 88%, and 90%, respectively. The proposed method proved to be simple and reliable for the determination of three fluoroquinolones.  相似文献   

20.
Thi report describes the determination of thiacetazone in human and rat plasma by direct-injection high-performance liquid chromatography (HPLC). Plasma filtrate (50 μl) was injected directly into the internal surface reversed-phase (ISRP) mixed-functional phenyl column (Capcell Pak, 50×4.6 mm, 5 μm) and eluted with an aqueous mobile phase containing 7.5% acetonitrile at a flow-rate of 1 ml/min. With UV detection at 322 nm, thiacetazone eluted at 11.0 min whereas endogenous interferences eluted before 5 min. The lower detection limit for a 50-μl sample at a signal-to-noise ratio of 5 was 63 ng/ml, which was several hundred fold lower than its cytotoxic concentrations determined from in vitro cell line studies. At a concentration range of 0.17 to 2.7 μg/ml, the recovery of thiacetazone was 98.0±4.4% (mean±S.D.). The intra- and inter-day coefficients of variation were 3.0±1.4% and 4.2±2.1%, respectively. This method was successfully applied to study the pharmacokinetics of thiacetazone in rats. The direct injection method is simple, requires small sample volume and does not require sample extraction, internal standard, or gradient elution.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号