首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The volume and fluid pressure characteristics of the intact bone marrow is incompletely understood. We used microspheres and lipoproteins for measurements of intravascular volume (IVV) and EDTA for interstitial fluid volume (IFV) within the rat bone marrow. Interstitial fluid pressure (IFP) was determined with micropipettes connected to a servo-controlled counter-pressure system. Both the microspheres and the lipoproteins yielded estimates of IVV of approximately 1 ml/100 g. After a brief reactive hyperemia, IVV increased to 2.5 ml/100 g, whereas IFV decreased with approximately 1.5 ml/100 g, so that total extracellular volume did not change. Baseline bone marrow IFP was 9.7 mmHg. The hyperemia led to a transient twofold increase in IFP, whereas a marked blood loss decreased IFP by almost one-half. These novel data suggest that extracellular volume and IFP within the bone marrow can be measured with tracer methods and the micropuncture technique. The responses of IVV, IFV, and IFP during changes in blood flow to the bone marrow suggest a tight regulation and are thus compatible with those for a low-compliant tissue.  相似文献   

2.
The role of red blood cell (RBC) aggregation as a determinant of in vivo blood flow is still unclear. This study was designed to investigate the influence of a well-controlled enhancement of RBC aggregation on blood flow resistance in an isolated-perfused heart preparation. Guinea pig hearts were perfused through a catheter inserted into the root of the aorta using a pressure servo-controlled pump system that maintained perfusion pressures of 30 to 100 mmHg. The hearts were beating at their intrinsic rates and pumping against the perfusion pressure. RBC aggregation was increased by Pluronic (F98) coating of RBC at a concentration 0.025 mg/ml, corresponding to about a 100% increment in RBC aggregation as measured by erythrocyte sedimentation rate. Isolated heart preparations were perfused with 0.40 l/l hematocrit unmodified guinea pig blood and with Pluronic-coated RBC suspensions in autologous plasma. At high perfusion pressures there were no significant differences between the flow resistance values for the two perfusates, with differences in flow resistance only becoming significant at lower perfusion pressures. These results can be interpreted to reflect the shear dependence of RBC aggregation: higher shear forces associated with higher perfusion pressures should have dispersed RBC aggregates resulting in blood flow resistances similar to control values. Experiments repeated in preparations in which the smooth muscle tone was inhibited by pre-treatment with papaverine indicated that significant effects of enhanced RBC aggregation could be detected at higher perfusion pressures, underlining the compensatory role of vasomotor control mechanisms.  相似文献   

3.
Compared with arterial hemodynamics, there has been relatively little study of venous hemodynamics. We propose that the venous system behaves just like the arterial system: waves propagate on a time-varying reservoir, the windkessel, which functions as the reverse of the arterial windkessel. During later diastole, pressure increases exponentially to approach an asymptotic value as inflow continues in the absence of outflow. Our study in eight open-chest dogs showed that windkessel-related arterial resistance was approximately 62% of total systemic vascular resistance, whereas windkessel-related venous resistance was only approximately 7%. Total venous compliance was found to be 21 times larger than arterial compliance (n = 3). Inferior vena caval compliance (0.32 +/- 0.015 ml x mmHg(-1) x kg(-1); mean +/- SE) was approximately 14 times the aortic compliance (0.023 +/- 0.002 ml x mmHg(-1) x kg(-1); n = 8). Despite greater venous compliance, the variation in venous windkessel volume (i.e., compliance x windkessel pulse pressure; 7.8 +/- 1.1 ml) was only approximately 32% of the variation in aortic windkessel volume (24.3 +/- 2.9 ml) because of the larger arterial pressure variation. In addition, and contrary to previous understanding, waves generated by the right heart propagated upstream as far as the femoral vein, but excellent proportionality between the excess pressure and venous outflow suggests that no reflected waves returned to the right atrium. Thus the venous windkessel model not only successfully accounts for variations in the venous pressure and flow waveforms but also, in combination with the arterial windkessel, provides a coherent view of the systemic circulation.  相似文献   

4.
Numerous studies have focused on the metabolic contributions of glucose and other substrates in isolated tissue preparations by examining the effects of eliminating glucose from the physiologic perfusate or bath solution. To date, however, an effective method of glucose removal from the blood supply to selected tissue in the whole animal model has not been available. We have developed a method for blood glucose removal by continuous flow dialysis. This method was used to generate isolated coronary hypoglycemia for an investigation of myocardial metabolic substrate selection during hypoperfusion in open-chest, anesthetized dogs. Arterial blood was passed through the dialysis system against an isotonic and physiologic dialysate solution prior to controlled coronary perfusion. During normal perfusion pressure (100 mmHg), with a coronary blood flow of 32 ± 4 ml/min, arterial blood glucose was reduced from 3.26 ± 0.31 to 0.54 ± 0.14 mM. When blood flow was reduced to 12 ± 3 ml/min with lower perfusion pressure (40 mmHg), dialysis reduced arterial glucose from 3.53 ± 0.36 to 0.15 ± 0.03 mM. We conclude that this is an effective method for producing regional hypoglycemia.  相似文献   

5.
A modified heart-lung preparation of the rat, which permits measuring systolic and diastolic coronary flow separately and enables coronary compliance to be evaluated, is described. The systemic circulation was substituted by a shunt circuit, and the elastic properties of the arterial tree were mimicked by a rubber balloon. Systolic and diastolic coronary flow was evaluated from the pulmonary and aortic flow signal. Integrated phasic pulmonary flow represented right ventricular stroke volume. Integrated phasic systolic aortic flow represented left ventricular stroke volume minus that volume flowing into the coronary arteries during systole, because the aortic flow probe had to be inserted distal to the origin of the coronary vessels. Because right and left ventricular stroke volume was identical under steady-state conditions, the difference between systolic pulmonary and systolic aortic flow resulted in systolic coronary flow. Diastolic coronary flow was measured by means of the retrograde flow through the aortic flow probe. Coronary compliance was calculated according to Frank's windkessel model from coronary resistance and from central diastolic aortic pressure, which decayed exponentially after switching out the rubber balloon and the shunt circuit. It could be shown that the proportion of systolic to diastolic coronary flow depends on coronary compliance.  相似文献   

6.
Animal experiments have shown that the coronary circulation is pressure distensible, i.e., myocardial blood volume (MBV) increases with perfusion pressure. In humans, however, corresponding measurements are lacking so far. We sought to quantify parameters reflecting coronary distensibility such as MBV and coronary resistance (CR) during and after coronary angioplasty. Thirty patients with stable coronary artery disease underwent simultaneous coronary perfusion pressure assessment and myocardial contrast echocardiography (MCE) of 37 coronary arteries and their territories during and after angioplasty. MCE yielded MBV and myocardial blood flow (MBF; in ml · min(-1) · g(-1)). Complete data sets were obtained in 32 coronary arteries and their territories from 26 patients. During angioplasty, perfusion pressure, i.e., coronary occlusive pressure, and MBV varied between 9 and 57 mmHg (26.9 ± 11.9 mmHg) and between 1.2 and 14.5 ml/100 g (6.7 ± 3.7 ml/100 g), respectively. After successful angioplasty, perfusion pressure and MBV increased significantly (P < 0.001 for both) and varied between 64 and 118 mmHg (93.5 ± 12.8 mmHg) and between 3.7 and 17.3 ml/100 g (9.8 ± 3.4 ml/100 g), respectively. Mean MBF increased from 31 ± 20 ml · min(-1) · g(-1) during coronary occlusion, reflecting collateral flow, to 121 ± 33 ml · min(-1) · g(-1) (P < 0.01), whereas mean CR, i.e., the ratio of perfusion pressure and MBF, decreased by 20% (P < 0.001). In conclusion, the human coronary circulation is pressure distensible. MCE allows for the quantification of CR and MBV in humans.  相似文献   

7.
Blood in the splanchnic vasculature can be transferred to the extremities. We quantified such blood shifts in normal subjects by measuring trunk volume by optoelectronic plethysmography, simultaneously with changes in body volume by whole body plethysmography during contractions of the diaphragm and abdominal muscles. Trunk volume changes with blood shifts, but body volume does not so that the blood volume shifted between trunk and extremities (Vbs) is the difference between changes in trunk and body volume. This is so because both trunk and body volume change identically with breathing and gas expansion or compression. During tidal breathing Vbs was 50–75 ml with an ejection fraction of 4–6% and an output of 750–1500 ml/min. Step increases in abdominal pressure resulted in rapid emptying presumably from the liver with a time constant of 0.61±0.1SE sec. followed by slower flow from non-hepatic viscera. The filling time constant was 0.57±0.09SE sec. Splanchnic emptying shifted up to 650 ml blood. With emptying, the increased hepatic vein flow increases the blood pressure at its entry into the inferior vena cava (IVC) and abolishes the pressure gradient producing flow between the femoral vein and the IVC inducing blood pooling in the legs. The findings are important for exercise because the larger the Vbs the greater the perfusion of locomotor muscles. During asystolic cardiac arrest we calculate that appropriate timing of abdominal compression could produce an output of 6 L/min. so that the abdominal circulatory pump might act as an auxiliary heart.  相似文献   

8.
A simplified model of arterial blood pressure intended for use in model-based signal processing applications is presented. The main idea is to decompose the pressure into two components: a travelling wave which describes the fast propagation phenomena predominating during the systolic phase and a windkessel flow that represents the slow phenomena during the diastolic phase. Instead of decomposing the blood pressure pulse into a linear superposition of forward and backward harmonic waves, as in the linear wave theory, a nonlinear superposition of travelling waves matched to a reduced physical model of the pressure, is proposed. Very satisfactory experimental results are obtained by using forward waves, the N-soliton solutions of a Korteweg–de Vries equation in conjunction with a two-element windkessel model. The parameter identifiability in the practically important 3-soliton case is also studied. The proposed approach is briefly compared with the linear one and its possible clinical relevance is discussed.  相似文献   

9.
The dynamics of the cerebral vascular response to blood pressure changes in hypertensive humans is poorly understood. Because cerebral blood flow is dependent on adequate perfusion pressure, it is important to understand the effect of hypertension on the transfer of pressure to flow in the cerebrovascular system of elderly people. Therefore, we examined the effect of spontaneous and induced blood pressure changes on beat-to-beat and within-beat cerebral blood flow in three groups of elderly people: normotensive, controlled hypertensive, and uncontrolled hypertensive subjects. Cerebral blood flow velocity (transcranial Doppler), blood pressure (Finapres), heart rate, and end-tidal CO(2) were measured during the transition from a sit to stand position. Transfer function gains relating blood pressure to cerebral blood flow velocity were assessed during steady-state sitting and standing. Cerebral blood flow regulation was preserved in all three groups by using changes in cerebrovascular resistance, transfer function gains, and the autoregulatory index as indexes of cerebral autoregulation. Hypertensive subjects demonstrated better attenuation of cerebral blood flow fluctuations in response to blood pressure changes both within the beat (i.e., lower gain at the cardiac frequency) and in the low-frequency range (autoregulatory, 0.03-0.07 Hz). Despite a better pressure autoregulatory response, hypertensive subjects demonstrated reduced reactivity to CO(2). Thus otherwise healthy hypertensive elderly subjects, whether controlled or uncontrolled with antihypertensive medication, retain the ability to maintain cerebral blood flow in the face of acute changes in perfusion pressure. Pressure regulation of cerebral blood flow is unrelated to cerebrovascular reactivity to CO(2).  相似文献   

10.
The muscle pump theory holds that contraction aids muscle perfusion by emptying the venous circulation, which lowers venous pressure during relaxation and increases the pressure gradient across the muscle. We reasoned that the influence of a reduction in venous pressure could be determined after maximal pharmacological vasodilation, in which the changes in vascular tone would be minimized. Mongrel dogs (n = 7), instrumented for measurement of hindlimb blood flow, ran on a treadmill during continuous intra-arterial infusion of saline or adenosine (15-35 mg/min). Adenosine infusion was initiated at rest to achieve the highest blood flow possible. Peak hindlimb blood flow during exercise increased from baseline by 438 +/- 34 ml/min under saline conditions but decreased by 27 +/- 18 ml/min during adenosine infusion. The absence of an increase in blood flow in the vasodilated limb indicates that any change in venous pressure elicited by the muscle pump was not adequate to elevate hindlimb blood flow. The implication of this finding is that the hyperemic response to exercise is primarily attributable to vasodilation in the skeletal muscle vasculature.  相似文献   

11.
We extend our recently published windkessel-wave interpretation of vascular function to the wave intensity analysis (WIA) of left ventricular (LV) filling dynamics by separating the pressure changes due to the windkessel from those due to traveling waves. With the use of LV compliance, the change in pressure due solely to LV volume changes (windkessel pressure) can be isolated. Inasmuch as the pressure measured in the cardiovascular system is the sum of its windkessel and wave components (excess pressure), it can be substituted into WIA, yielding the isolated wave effects on LV filling. Our study of six open-chest dogs demonstrated that once the windkessel effects are removed from WIA, the energy of diastolic suction is 2.6 times greater than we previously calculated. Volume-related changes in pressure (i.e., the windkessel or reservoir effect) must be considered first when wave motion is analyzed.  相似文献   

12.
The purpose of this study was to introduce and validate a new algorithm to estimate instantaneous aortic blood flow (ABF) by mathematical analysis of arterial blood pressure (ABP) waveforms. The algorithm is based on an autoregressive with exogenous input (ARX) model. We applied this algorithm to diastolic ABP waveforms to estimate the autoregressive model coefficients by requiring the estimated diastolic flow to be zero. The algorithm incorporating the coefficients was then applied to the entire ABP signal to estimate ABF. The algorithm was applied to six Yorkshire swine data sets over a wide range of physiological conditions for validation. Quantitative measures of waveform shape (standard deviation, skewness, and kurtosis), as well as stroke volume and cardiac output from the estimated ABF, were computed. Values of these measures were compared with those obtained from ABF waveforms recorded using a Transonic aortic flow probe placed around the aortic root. The estimation errors were compared with those obtained using a windkessel model. The ARX model algorithm achieved significantly lower errors in the waveform measures, stroke volume, and cardiac output than those obtained using the windkessel model (P < 0.05).  相似文献   

13.
The effectiveness of localized retrograde coronary venous perfusion (RCVP) in preventing or reversing myocardial ischemia after acute ligation of a coronary artery is described. Ten domestic pigs (Group I) underwent aorto left anterior coronary vein grafting with RCVP at systemic pressure. In another set of ten pigs (Group II), the coronary vein was similarly grafted, but the proximal end of the graft was perfused with oxygenated blood by means of an external pump at reduced pressure and flow. In both groups, RCVP successfully reversed the mechanical or electrical effects produced by 2 to 5 minutes of acute arterial ligation. After several hours, Group I animals showed evidence of acute ischemia and developing infarction. Group II animals, however, were maintained for 7 hours or more with regional RCVP and no evidence of ischemia. Retrograde coronary venous perfusion at reduced pressure may be more effective than perfusion at systemic pressure in providing myocardial blood flow.  相似文献   

14.
15.
The differences in shape between central aortic pressure (P(Ao)) and flow waveforms have never been explained satisfactorily in that the assumed explanation (substantial reflected waves during diastole) remains controversial. As an alternative to the widely accepted frequency-domain model of arterial hemodynamics, we propose a functional, time-domain, arterial model that combines a blood conducting system and a reservoir (i.e., Frank's hydraulic integrator, the windkessel). In 15 anesthetized dogs, we measured P(Ao), flows, and dimensions and calculated windkessel pressure (P(Wk)) and volume (V(Wk)). We found that P(Wk) is proportional to thoracic aortic volume and that the volume of the thoracic aorta comprises 45.1 +/- 2.0% (mean +/- SE) of the total V(Wk). When we subtracted P(Wk) from P(Ao), we found that the difference (excess pressure) was proportional to aortic flow, thus resolving the differences between P(Ao) and flow waveforms and implying that reflected waves were minimal. We suggest that P(Ao) is the instantaneous summation of a time-varying reservoir pressure (i.e., P(Wk)) and the effects of (primarily) forward-traveling waves in this animal model.  相似文献   

16.
A method of retrograde perfusion of the myocardium has been developed in dogs. It consists of a double lumen balloon-tipped catheter inserted transvenously into the coronary sinus, with one lumen connected to a roller pump, the other to a helium counterpulsing pump. Oxygenated heparinized blood is obtained from the femoral artery and pumped continuously into the coronary sinus at a pressure of 50-75 mm Hg. The balloon is inflated during diastole, sealing the coronary sinus and promoting retrograde flow, and is deflated during systole, allowing blood drainage into the right atrium and preventing venous congestion. Thirteen anesthetized open-chest dogs were subjected to 15 minutes of proximal LAD artery occlusion and 30 minutes of diastolic coronary sinus perfusion (DCSP). The area of ischemia was mapped by means of platinum electrodes capable of simultaneously measuring myocardial tissue oxygen tension M(p)O(2)) and electrograms. Reduction of M(p)O(2) with simultaneous elevation of the ST segment on the corresponding electrogram was considered an indication of ischemia. Diastolic coronary sinus perfusion improved myocardial oxygen tension in the ischemic myocardium, reduced ST segment elevation, and tended to restore arterial blood pressure. Histologically, there was no intramyocardial hemorrhage.  相似文献   

17.
Many attempts to improve the perfusion of mammalian tissues aim at changes of the osmotic pressure. We describe a method for fixation of nervous tissues controlling both the hydrostatic pressure and the flow rate of a perfusion solution. The constancy of these parameters is guaranteed by an electronically controlled perfusion pump. Thus, a more uniform and complete preservation can be achieved. Further advantages of this method include provision for a rapid succession of rinsing and fixation solution and a continuous control of the hydrostatic pressure during perfusion.  相似文献   

18.
The influence of left ventricle pressure and volume changes on coronary blood flow was investigated in eight anesthetized dogs. Coronary artery pressure-flow relationships were determined at two levels of left ventricular pressure and volume. The distribution of blood flow within the myocardium was also determined when these relationships varied. Reducing left ventricle pressures and volumes increased heart rate. Rate-pressure product, diastolic coronary pressure, myocardial O2 consumption, total, subendocardial and subepicardial flow decreased. Hematocrit and blood gas data were unchanged. The pressure-flow relationships were shifted leftward (p = 0.001) but the range of autoregulation was not altered. At low left ventricle pressures and volumes, the lower coronary artery pressure limit was shifted leftward (from 75 to 45 mm Hg (1 mm Hg = 133.3 Pa)), while total, subendocardial, and subepicardial blood flow did not change compared with the control. Below the lower coronary artery pressure limit, subendocardial but not subepicardial flow decreased, resulting in maldistribution of flow across the left ventricular wall. When coronary pressure was reset between control and the lower coronary artery pressure limit, subendocardial flow was restored. These results show that the lower coronary artery pressure limit can be shifted leftward while the distribution of blood flow across the left ventricular wall is preserved.  相似文献   

19.
A method for rapidly changing perfusion pressure to the relatively intact dog hindlimb using vacuum assistance is proposed and demonstrated. The hindlimb of an anesthetized dog is inserted into a rigid sealed enclosure for application of a partial vacuum. The circulation of the hindlimb remains entirely intact except for a single large noncollapsible catheter placed in the femoral vein and connected to a servo-pump. The servo-pump maintains the venous pressure equal to the enclosure pressure even when this pressure is in the partial vacuum state. The automatically adjusted pumping rate of this pump also provides a continuous measure of the blood flow in the limb as it returns the blood via a jugular catheter. In nine dogs the systemic arterial pressure was maintained constant, and the enclosure pressure and venous pressure were set to subatmospheric levels, thus changing the perfusion pressure to any desired value up to 220 mmHg. The procedure had minimal impact on the central circulation, suggesting that the technique may be useful in studying hemodynamics of the hindlimb or other organs at high perfusion pressure, which has always been difficult to achieve experimentally. In the nine dogs, blood flow responses were observed at both elevated and reduced perfusion pressure. The changes in measured blood flow induced by the changes in perfusion pressure were variable but were generally directly proportional to perfusion pressure in the steady state.  相似文献   

20.
A hemodynamic analysis of coronary blood flow must be based on the measured branching pattern and vascular geometry of the coronary vasculature. We recently developed a computer reconstruction of the entire coronary arterial tree of the porcine heart based on previously measured morphometric data. In the present study, we carried out an analysis of blood flow distribution through a network of millions of vessels that includes the entire coronary arterial tree down to the first capillary branch. The pressure and flow are computed throughout the coronary arterial tree based on conservation of mass and momentum and appropriate pressure boundary conditions. We found a power law relationship between the diameter and flow of each vessel branch. The exponent is approximately 2.2, which deviates from Murray's prediction of 3.0. Furthermore, we found the total arterial equivalent resistance to be 0.93, 0.77, and 1.28 mmHg.ml(-1).s(-1).g(-1) for the right coronary artery, left anterior descending coronary artery, and left circumflex artery, respectively. The significance of the present study is that it yields a predictive model that incorporates some of the factors controlling coronary blood flow. The model of normal hearts will serve as a physiological reference state. Pathological states can then be studied in relation to changes in model parameters that alter coronary perfusion.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号