首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
RG7652 is a human immunoglobulin 1 (IgG1) monoclonal antibody (mAb) targeting proprotein convertase subtilisin/kexin type 9 (PCSK9) and is designed for the treatment of hypercholesterolemia. A target-binding enzyme-linked immunosorbent assay (ELISA) was developed to measure RG7652 levels in human serum in a Phase I study. Although target-binding assay formats are generally used to quantify free therapeutic, the actual therapeutic species being measured are affected by assay conditions, such as sample dilution and incubation time, and levels of soluble target in the samples. Therefore, in the presence of high concentrations of circulating target, the choice of reagents and assay conditions can have a significant effect on the observed pharmacokinetic (PK) profiles. Phase I RG7652 PK analysis using the ELISA data resulted in a nonlinear dose normalized exposure. An investigation was conducted to characterize the ELISA to determine whether the assay format and reagents may have contributed to the PK observation. In addition, to confirm the ELISA results, a second orthogonal method, liquid chromatography tandem mass spectrometry (LC-MS/MS) using a signature peptide as surrogate, was developed and implemented. A subset of PK samples, randomly selected from half of the subjects in the 6 single ascending dose (SAD) cohorts in the Phase I clinical study, was analyzed with the LC-MS/MS assay, and the data were found to be comparable to the ELISA data. This paper illustrates the importance of reagent characterization, as well as the benefits of using an orthogonal approach to eliminate bioanalytical contributions when encountering unexpected observations.  相似文献   

2.
《MABS-AUSTIN》2013,5(5):623-631
To interpret pharmacokinetic (PK) data of biotherapeutics, it is critical to understand which drug species is being measured by the PK assay. For therapeutic antibodies, it is generally accepted that “free” circulating antibodies are the pharmacologically active form needed to determine the PK/ pharmacodynamic (PD) relationship, safety margin calculations, and dose projections from animals to humans and the eventual characterization of the exposure in the clinic. However, “total” drug may be important in evaluating the dynamic interaction between the drug and the target, as well as the total drug exposure. In the absence of or with low amounts of soluble ligand /shed receptor, total and free drug species are often equivalent and their detection is less sensitive to assay formats or reagent choices. In contrast, in the presence of a significant amount of ligand, assay design and characterization of assay reagents are critical to understanding the PK profiles. Here, we present case studies where different assay formats affected measured PK profiles and data interpretation. The results from reagent characterizations provide a potential explanation for the observed discrepancies and highlight the importance of reagent characterization in understanding which drug species are being measured to accurately interpret PK parameters.  相似文献   

3.
To interpret pharmacokinetic (PK) data of biotherapeutics, it is critical to understand which drug species is being measured by the PK assay. For therapeutic antibodies, it is generally accepted that “free” circulating antibodies are the pharmacologically active form needed to determine the PK/ pharmacodynamic (PD) relationship, safety margin calculations, and dose projections from animals to humans and the eventual characterization of the exposure in the clinic. However, “total” drug may be important in evaluating the dynamic interaction between the drug and the target, as well as the total drug exposure. In the absence of or with low amounts of soluble ligand /shed receptor, total and free drug species are often equivalent and their detection is less sensitive to assay formats or reagent choices. In contrast, in the presence of a significant amount of ligand, assay design and characterization of assay reagents are critical to understanding the PK profiles. Here, we present case studies where different assay formats affected measured PK profiles and data interpretation. The results from reagent characterizations provide a potential explanation for the observed discrepancies and highlight the importance of reagent characterization in understanding which drug species are being measured to accurately interpret PK parameters.  相似文献   

4.
Pharmacokinetic (PK) and immunohistochemistry (IHC) assays are essential to the evaluation of the safety and efficacy of therapeutic monoclonal antibodies (mAb) during drug development. These methods require reagents with a high degree of specificity because low concentrations of therapeutic antibody need to be detected in samples containing high concentrations of endogenous human immunoglobulins. Current assay reagent generation practices are labor-intensive and time-consuming. Moreover, these practices are molecule-specific and so only support one assay for one program at a time. Here, we describe a strategy to generate a unique assay reagent, 10C4, that preferentially recognizes a panel of recombinant human mAbs over endogenous human immunoglobulins. This “panel-specific” feature enables the reagent to be used in PK and IHC assays for multiple structurally-related therapeutic mAbs. Characterization revealed that the 10C4 epitope is conformational, extensive and mainly composed of non-CDR residues. Most key contact residues were conserved among structurally-related therapeutic mAbs, but the combination of these residues exists at low prevalence in endogenous human immunoglobulins. Interestingly, an indirect contact residue on the heavy chain of the therapeutic appears to play a critical role in determining whether or not it can bind to 10C4, but has no affect on target binding. This may allow us to improve the binding of therapeutic mAbs to 10C4 for assay development in the future. Here, for the first time, we present a strategy to develop a panel-specific reagent that can expedite the development of multiple clinical assays for structurally-related therapeutic mAbs.  相似文献   

5.
随着生物技术药物研发的大力开展,单抗类药物的药动学评价越来越受到重视。对近年来应用LC-MS/MS检测单抗类药物药动 学特征的文献进行归纳,总结其样品前处理的不同方法及各自优缺点和适用范围,为单抗类药物LC-MS/MS检测方法的进一步研究提供 参考。  相似文献   

6.
While ELISA is a frequently used means of assessing 8-oxo-7,8-dihydro-2-deoxyguanosine (8-oxodG) in biological fluids, differences in baseline urinary 8-oxodG levels, compared to chromatographic techniques, have raised questions regarding the specificity of immunoassays. Recently, ELISA of salivary 8-oxodG has been used to report on periodontal disease. We compared salivary 8-oxodG levels, determined by two commercial ELISA kits, to liquid chromatography-tandem mass spectrometry (LC-MS/MS) with prior purification using solid-phase extraction. While values were obtained with both ELISA kits, salivary 8-oxodG values were below or around the limit of detection of our LC-MS/MS assay. As the limit of detection for the LC-MS/MS procedure is much lower than ELISA, we concluded that the assessment of salivary 8-oxodG by ELISA is not accurate. In contrast to previous studies, ELISA levels of urinary 8-oxodG (1.67 ± 0.53 pmol/μmol creatinine) were within the range reported previously only for chromatographic assays, although still significantly different than LC-MS/MS (0.41 ± 0.39 pmol/μmol creatinine; p = 0.002). Furthermore, no correlation with LC-MS/MS was seen. These results question the ability of ELISA approaches, at present, to specifically determine absolute levels of 8-oxodG in saliva and urine. Ongoing investigation in our laboratories aims to identify the basis of the discrepancy between ELISA and LC-MS/MS.  相似文献   

7.
While ELISA is a frequently used means of assessing 8-oxo-7,8-dihydro-2-deoxyguanosine (8-oxodG) in biological fluids, differences in baseline urinary 8-oxodG levels, compared to chromatographic techniques, have raised questions regarding the specificity of immunoassays. Recently, ELISA of salivary 8-oxodG has been used to report on periodontal disease. We compared salivary 8-oxodG levels, determined by two commercial ELISA kits, to liquid chromatography-tandem mass spectrometry (LC-MS/MS) with prior purification using solid-phase extraction. While values were obtained with both ELISA kits, salivary 8-oxodG values were below or around the limit of detection of our LC-MS/MS assay. As the limit of detection for the LC-MS/MS procedure is much lower than ELISA, we concluded that the assessment of salivary 8-oxodG by ELISA is not accurate. In contrast to previous studies, ELISA levels of urinary 8-oxodG (1.67 ± 0.53 pmol/μmol creatinine) were within the range reported previously only for chromatographic assays, although still significantly different than LC-MS/MS (0.41 ± 0.39 pmol/μmol creatinine; p = 0.002). Furthermore, no correlation with LC-MS/MS was seen. These results question the ability of ELISA approaches, at present, to specifically determine absolute levels of 8-oxodG in saliva and urine. Ongoing investigation in our laboratories aims to identify the basis of the discrepancy between ELISA and LC-MS/MS.  相似文献   

8.
Non-invasive monitoring of oxidative stress is highly desirable. Urinary 7,8-8-oxo-7,8-dihydro-2'-deoxyguanosine (8-oxodG) is a biologically relevant and convenient analytical target. However, immunoassays can over-estimate levels of urinary 8-oxodG. Measurement of more than one DNA oxidation product in urine would be advantageous in terms of mechanistic information. Urines samples were analysed for 8-oxodG by solid-phase extraction/LC-MS/MS and ELISA. The solid-phase extraction/LC-MS/MS assay was also applied to the analysis of urinary 7,8-dihydro-8-oxo-2'-deoxyadenosine (8-oxodA). Concurring with previous reports, urinary 8-oxodG measured by ELISA was significantly higher than levels measured by LC-MS/MS. However, apparent improvement in the specificity of the commercially available Japanese Institute for the Control of Ageing (JaICA) ELISA brought mean LC-MS/MS and ELISA measurements of urinary 8-oxodG into agreement. Urinary 8-oxodA was undetectable in all urines, despite efficient recovery by solid phase extraction. Exploitation of the advantages of ELISA may be enhanced by a simple modification to the assay procedure, although chromatographic techniques still remain the 'gold standard' techniques for analysis of urinary 8-oxodG. Urinary 8-oxodA is either not present or below the limit of detection of the instrumentation.  相似文献   

9.
Non-invasive monitoring of oxidative stress is highly desirable. Urinary 7,8-8-oxo-7,8-dihydro-2’-deoxyguanosine (8-oxodG) is a biologically relevant and convenient analytical target. However, immunoassays can over-estimate levels of urinary 8-oxodG. Measurement of more than one DNA oxidation product in urine would be advantageous in terms of mechanistic information. Urines samples were analysed for 8-oxodG by solid-phase extraction/LC-MS/MS and ELISA. The solid-phase extraction/LC-MS/MS assay was also applied to the analysis of urinary 7,8-dihydro-8-oxo-2’-deoxyadenosine (8-oxodA). Concurring with previous reports, urinary 8-oxodG measured by ELISA was significantly higher than levels measured by LC-MS/MS. However, apparent improvement in the specificity of the commercially available Japanese Institute for the Control of Ageing (JaICA) ELISA brought mean LC-MS/MS and ELISA measurements of urinary 8-oxodG into agreement. Urinary 8-oxodA was undetectable in all urines, despite efficient recovery by solid phase extraction. Exploitation of the advantages of ELISA may be enhanced by a simple modification to the assay procedure, although chromatographic techniques still remain the ‘gold standard’ techniques for analysis of urinary 8-oxodG. Urinary 8-oxodA is either not present or below the limit of detection of the instrumentation.  相似文献   

10.
2-Hydroxypropyl-β-cyclodextrin (HP-β-CD), a widely used excipient for drug formulation, has emerged as an investigational new drug for the treatment of Niemann-Pick type C1 (NPC1) disease, a neurodegenerative cholesterol storage disorder. Development of a sensitive quantitative LC-MS/MS assay to monitor the pharmacokinetics (PKs) of HP-β-CD required for clinical trials has been challenging owing to the dispersity of the HP-β-CD. To support a phase 1 clinical trial for ICV delivery of HP-β-CD in NPC1 patients, novel methods for quantification of HP-β-CD in human plasma and cerebrospinal fluid (CSF) using LC-MS/MS were developed and validated: a 2D-LC-in-source fragmentation-MS/MS (2D-LC-IF-MS/MS) assay and a reversed phase ultra performance LC-MS/MS (RP-UPLC-MS/MS) assay. In both assays, protein precipitation and “dilute and shoot” procedures were used to process plasma and CSF, respectively. The assays were fully validated and in close agreement, and allowed determination of PK parameters for HP-β-CD. The LC-MS/MS methods are ∼100-fold more sensitive than the current HPLC assay, and were successfully employed to analyze HP-β-CD in human plasma and CSF samples to support the phase 1 clinical trial of HP-β-CD in NPC1 patients.  相似文献   

11.
Multiple control strategies, including a downstream purification process with well-controlled parameters and a comprehensive release or characterization for intermediates or drug substances, were implemented to mitigate the potential risk of host cell proteins (HCPs) in one concentrated fed-batch (CFB) mode manufactured product. A host cell process specific enzyme-linked immunosorbent assay (ELISA) method was developed for the quantitation of HCPs. The method was fully validated and showed good performance including high antibody coverage. This was confirmed by 2D Gel-Western Blot analysis. Furthermore, a LC-MS/MS method with non-denaturing digestion and a long gradient chromatographic separation coupled with data dependent acquisition (DDA) on a Thermo/QE-HF-X mass spectrometer was developed as an orthogonal method to help identify the specific types of HCPs in this CFB product. Because of the high sensitivity, selectivity and adaptability of the new developed LC-MS/MS method, significantly more species of HCP contaminants were able to be identified. Even though high levels of HCPs were observed in the harvest bulk of this CFB product, the development of multiple processes and analytical control strategies may greatly mitigate potential risks and reduce HCPs contaminants to a very low level. No high-risk HCP was identified and the total amount of HCPs was very low in the CFB final product.  相似文献   

12.
A sensitive and specific competitive enzyme-linked immunosorbent assay (ELISA) for rat prolactin was developed using reagents from the National Institute of Arthritis, Diabetes, Digestive Diseases and Kidney. In this assay soluble prolactin and prolactin adsorbed to a solid-phase support compete for rabbit anti-prolactin antibody binding sites. Therefore, a high concentration of soluble prolactin in the sample will result in a low concentration of antibody immobilized to the adsorbed prolactin. The immobilized antibody-prolactin complex is detected and quantified using goat anti-rabbit immunoglobulin G covalently conjugated to the enzyme horseradish peroxidase. Assay parameters were optimized by investigating the concentration of reagents and the reaction kinetics in each of the assay steps. The assay can be performed in 24 h. A sensitivity range of 0.06 to 6 ng in the region of 90 to 10% binding was obtained. Near 50% binding (0.6 ng), the intraassay coefficient of variation (CV) was 4.2% and the interassay CV was 7.6%. The correlation between radioimmunoassay and the ELISA was 0.868. Selected applications of the assay are described. The assay should prove a useful alternative to the radioimmunoassay in those instances where steps involving the use of 125I become limiting, for example, iodination facility and gamma counter availability or prolonged reagent storage.  相似文献   

13.
LC-MS/MS has demonstrated potential for detecting plant pathogens. Unlike PCR or ELISA, LC-MS/MS does not require pathogen-specific reagents for the detection of pathogen-specific proteins and peptides. However, the MS/MS approach we and others have explored does require a protein sequence reference database and database-search software to interpret tandem mass spectra. To evaluate the limitations of database composition on pathogen identification, we analyzed proteins from cultured Ustilago maydis, Phytophthora sojae, Fusarium graminearum, and Rhizoctonia solani by LC-MS/MS. When the search database did not contain sequences for a target pathogen, or contained sequences to related pathogens, target pathogen spectra were reliably matched to protein sequences from nontarget organisms, giving an illusion that proteins from nontarget organisms were identified. Our analysis demonstrates that when database-search software is used as part of the identification process, a paradox exists whereby additional sequences needed to detect a wide variety of possible organisms may lead to more cross-species protein matches and misidentification of pathogens.  相似文献   

14.
A two-stage, multilevel assay quality control (QC) system was designed and implemented for two high stringency QC anthrax serological assays; a quantitative anti-PA IgG enzyme-linked immunosorbent assay (ELISA) and an anthrax lethal toxin neutralization activity (TNA) assay. The QC system and the assays were applied for the congressionally mandated Centers for Disease Control and Prevention (CDC) Phase 4 human clinical trial of anthrax vaccine adsorbed (AVA, BioThrax). A total of 57,284 human serum samples were evaluated by anti-PA enzyme-linked immunosorbent assay (ELISA) and 11,685 samples by anthrax lethal toxin neutralization activity (TNA) assay. The QC system demonstrated overall sample acceptance rates of 86% for ELISA and 90% for the TNA assays respectively. Monitoring of multiple assay and test sample variables showed no significant long term trends or degradation in any of the critical assay reagents or reportable values for both assays. Assay quality control data establish the functionality of the quality control system and demonstrates the reliability of the serological data generated using these assays.  相似文献   

15.
The clinical application of Traditional Chinese medicine (TCM), using several herbs in combination (called formulas), has a history of more than one thousand years. However, the bioactive compounds that account for their therapeutic effects remain unclear. We hypothesized that the material basis of a formula are those compounds with a high content in the decoction that are maintained at a certain level in the system circulation. Network pharmacology provides new methodological insights for complicated system studies. In this study, we propose combining pharmacokinetic (PK) analysis with network pharmacology to explore the material basis of TCM formulas as exemplified by the Bushen Zhuanggu formula (BZ) composed of Psoralea corylifolia L., Aconitum carmichaeli Debx., and Cnidium monnieri (L.) Cuss. A sensitive and credible liquid chromatography tandem mass spectrometry (LC-MS/MS) method was established for the simultaneous determination of 15 compounds present in the three herbs. The concentrations of these compounds in the BZ decoction and in rat plasma after oral BZ administration were determined. Up to 12 compounds were detected in the BZ decoction, but only 5 could be analyzed using PK parameters. Combined PK results, network pharmacology analysis revealed that 4 compounds might serve as the material basis for BZ. We concluded that a sensitive, reliable, and suitable LC-MS/MS method for both the composition and pharmacokinetic study of BZ has been established. The combination of PK with network pharmacology might be a potent method for exploring the material basis of TCM formulas.  相似文献   

16.
MHAA4549A is a human immunoglobulin G1 (IgG1) monoclonal antibody that binds to a highly conserved epitope on the stalk of influenza A hemagglutinin and blocks the hemagglutinin-mediated membrane fusion in the endosome, neutralizing all known human influenza A strains. Pharmacokinetics (PK) of MHAA4549A and its related antibodies were determined in DBA/2J and Balb-c mice at 5 mg/kg and in cynomolgus monkeys at 5 and 100 mg/kg as a single intravenous dose. Serum samples were analyzed for antibody concentrations using an ELISA and the PK was evaluated using WinNonlin software. Human PK profiles were projected based on the PK in monkeys using species-invariant time method. The human efficacious dose projection was based on in vivo nonclinical pharmacological active doses, exposure in mouse infection models and expected human PK. The PK profiles of MHAA4549A and its related antibody showed a linear bi-exponential disposition in mice and cynomolgus monkeys. In mice, clearance and half-life ranged from 5.77 to 9.98 mL/day/kg and 10.2 to 5.76 days, respectively. In cynomolgus monkeys, clearance and half-life ranged from 4.33 to 4.34 mL/day/kg and 11.3 to 11.9 days, respectively. The predicted clearance in humans was ~2.60 mL/day/kg. A single intravenous dose ranging from 15 to 45 mg/kg was predicted to achieve efficacious exposure in humans. In conclusion, the PK of MHAA4549A was as expected for a human IgG1 monoclonal antibody that lacks known endogenous host targets. The predicted clearance and projected efficacious doses in humans for MHAA4549A have been verified in a Phase 1 study and Phase 2a study, respectively.  相似文献   

17.
An LC-MS/MS method for determination of the break down product of N-ethyl-N'-(3-dimethylaminopropyl) carbodiimide (EDC) urea derivative, EDU, has been developed and validated for monitoring the residual coupling reagents. Results indicate that the method exhibits suitable specificity, sensitivity, precision, linearity and accuracy for quantification of residual EDU in the presence of meningococcal polysaccharide-diphtheria toxoid conjugate vaccine and other vaccine matrix compounds. The assay has been validated for a detection range of 10-100 ng/mL and then successfully transferred to quality control (QC) lab. This same method has also been applied to the determination of residual diaminohexane (DAH) in the presence of EDU. LC-MS/MS has proven to be useful as a quick and sensitive approach for simultaneous determination of multiple residual compounds in glycoconjugate vaccine samples.  相似文献   

18.
The catalytic activity of methionine aminopeptidase-2 (MetAP2) has been pharmacologically linked to cell growth, angiogenesis, and tumor progression, making this an attractive target for cancer therapy. An assay for monitoring specific protein changes in response to MetAP2 inhibition, allowing pharmacokinetic (PK)/pharmacodynamic (PD) models to be established, could dramatically improve clinical decision-making. Candidate MetAP2-specific protein substrates were discovered from undigested cell culture-derived proteomes by MALDI-/SELDI-MS profiling and a biochemical method using (35)S-Met labeled protein lysates. Substrates were identified either as intact proteins by FT-ICR-MS or applying in-gel protease digestions followed by LC-MS/MS. The combination of these approaches led to the discovery of novel MetAP2-specific substrates including thioredoxin-1 (Trx-1), SH3 binding glutamic acid rich-like protein (SH3BGRL), and eukaryotic elongation factor-2 (eEF2). These studies also confirmed glyceraldehye 3-phosphate dehydrogenase (GAPDH) and cyclophillin A (CypA) as MetAP2 substrates. Additional data in support of these proteins as MetAP2-specific substrates were provided by in vitro MetAP1/MetAP2 enzyme assays with the corresponding N-terminal derived peptides and 1D/2D Western analyses of cellular and tissue lysates. FT-ICR-MS characterization of all intact species of the 18 kDa substrate, CypA, enabled a SELDI-MS cell-based assay to be developed for correlating N-terminal processing and inhibition of proliferation. The MetAP2-specific protein substrates discovered in this study have diverse properties that should facilitate the development of reagents for testing in preclinical and clinical environments.  相似文献   

19.
《MABS-AUSTIN》2013,5(4):449-456
Hu12F6mu is an Fc-mutated, humanized anti-CD3 antibody developed in our lab. The aim of this study was to assess single dose escalation pharmacokinetics (PK) and safety profile of hu12F6mu and to measure the effects of the antibody on levels of circulating T cells over time. Twenty-seven patients receiving renal allografts were randomized to receive hu12F6mu intravenously at a single-dose of 2.5, 5 or 10 mg. The concentration-time data obtained by a validated ELISA method were subjected to non-compartmental PK analysis by DAS 2.1 software. Subgroups of CD2+, CD3+, CD4+ and CD8+ lymphocytes were monitored periodically by flow cytometry. Our results showed that hu12F6mu exhibited linear PK over the dose range of 2.5 to 10 mg. A significant decline in the proportion of T cells was observed immediately after the infusion, followed by a progressive increase occurring over the ensuing days of therapy. A significant negative correlation was observed between serum concentration of hu12F6mu and CD3+ cell proportion. Intravenous infusion of hu12F6mu was well-tolerated in patients receiving renal allografts. These results suggest that hu12F6mu may have potential as a therapeutic agent, although further studies are needed.  相似文献   

20.
Antibody-drug conjugates (ADCs) are designed to combine the exquisite specificity of antibodies to target tumor antigens with the cytotoxic potency of chemotherapeutic drugs. In addition to the general chemical stability of the linker, a thorough understanding of the relationship between ADC composition and biological disposition is necessary to ensure that the therapeutic window is not compromised by altered pharmacokinetics (PK), tissue distribution, and/or potential organ toxicity. The six-transmembrane epithelial antigen of prostate 1 (STEAP1) is being pursued as a tumor antigen target. To assess the role of ADC composition in PK, we evaluated plasma and tissue PK profiles in rats, following a single dose, of a humanized anti-STEAP1 IgG1 antibody, a thio-anti-STEAP1 (ThioMab) variant, and two corresponding thioether-linked monomethylauristatin E (MMAE) drug conjugates modified through interchain disulfide cysteine residues (ADC) and engineered cysteines (TDC), respectively. Plasma PK of total antibody measured by enzyme-linked immunosorbent assay (ELISA) revealed ~45% faster clearance for the ADC relative to the parent antibody, but no apparent difference in clearance between the TDC and unconjugated parent ThioMab. Total antibody clearances of the two unconjugated antibodies were similar, suggesting minimal effects on PK from cysteine mutation. An ELISA specific for MMAE-conjugated antibody indicated that the ADC cleared more rapidly than the TDC, but total antibody ELISA showed comparable clearance for the two drug conjugates. Furthermore, consistent with relative drug load, the ADC had a greater magnitude of drug deconjugation than the TDC in terms of free plasma MMAE levels. Antibody conjugation had a noticeable, albeit minor, impact on tissue distribution with a general trend toward increased hepatic uptake and reduced levels in other highly vascularized organs. Liver uptakes of ADC and TDC at 5 days postinjection were 2-fold and 1.3-fold higher, respectively, relative to the unmodified antibodies. Taken together, these results indicate that the degree of overall structural modification in anti-STEAP1-MMAE conjugates has a corresponding level of impact on both PK and tissue distribution.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏