首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Champy miniplates have been used in the treatment of craniofacial fractures and in osteotomies for correction of posttraumatic deformities, congenital craniofacial deformities, and secondary bony deformities due to pathologies such as hemangioma and neurofibroma. An additional use has been to stabilize free and vascularized bone grafts. The total number of cases reviewed were 50 (25 acute trauma, 4 vascularized mandible reconstruction, and 21 osteotomies of varied types). There were three infections, two in mandibular fractures that were comminuted and compound into the mouth and one in a compound comminuted fracture of the frontal and maxillary area that was judged to be infected when the plate was placed in position. Two plates have been obvious under the skin. No patient has requested plate removal. The advantages of plating in selected cases are decreased operating time, rigid fixation at surgery, good fixation of bone grafts, and the ability to remove intermaxillary fixation in children at the end of the procedure or within the first few postoperative days.  相似文献   

2.
The role of primary bone grafting in complex craniomaxillofacial trauma   总被引:5,自引:0,他引:5  
The role of craniofacial surgical techniques and immediate bone grafting in the management of complex craniofacial trauma has been reviewed. Four hundred and one patients with complex facial injuries have been treated. Two hundred and forty-one primary bone and cartilage grafts have been performed in 66 patients. Complex facial injuries should be managed by direct exposure, reduction, and fixation of all fractures utilizing interfragmentary wiring. Very comminuted or absent bone is replaced by immediate bone grafting, producing a stable skeleton without the need for external fixation devices. Associated mandibular fractures are managed with rigid internal fixation utilizing A-O technique. Results of immediate bone grafting have been excellent, and complications are rare. All deformities should be corrected, whenever possible, during the initial operation. This one-stage reconstruction of even the most complex facial injuries will prevent severe postoperative traumatic deformity and disability that may be extremely difficult or impossible to correct secondarily.  相似文献   

3.
The fate of plates and screws after facial fracture reconstruction.   总被引:2,自引:0,他引:2  
Rigid plate and screw fixation is the mainstay of treatment for complex fractures of the facial skeleton. Complications of plate and screw fixation include prominence, infection, exposure, and migration. Five hundred and seven patients undergoing plate and screw fixation for facial fractures (1112 fractures) from 1983 to 1988 were followed for complications. Sixty-one patients (12 percent) required hardware removal. The location on the facial skeleton influenced symptoms and the rate of hardware removal. Infection and exposure may be decreased with antiseptic irrigations, avoiding mucosal damage, attention to proper mucosal closure, and correct placement of plates. Prominence may be decreased by the use of microplates in the supraorbital, frontal, and naso-orbital-ethmoid locations.  相似文献   

4.
Surgery for mandibular condyle fractures must allow direct vision of the fracture, reduce surgical trauma and achieve reduction and fixation while avoiding facial nerve injury. This prospective study was conducted to introduce a new surgical approach for open reduction and internal fixation of mandibular condyle fractures using a modified transparotid approach via the parotid mini-incision, and surgical outcomes were evaluated. The modified transparotid approach via the parotid mini-incision was applied and rigid internal fixation using a small titanium plate was carried out for 36 mandibular condyle fractures in 31 cases. Postoperative follow-up of patients ranged from 3 to 26 months; in the first 3 months after surgery, outcomes for all patients were analyzed by evaluating the degree of mouth opening, occlusal relationship, facial nerve function and results of imaging studies. The occlusal relationships were excellent in all patients and none had symptoms of intraoperative ipsilateral facial nerve injury. The mean degree of mouth opening was 4.0 (maximum 4.8 cm, minimum 3.0 cm). No mandibular deviations were noted in any patient during mouth opening. CT showed complete anatomical reduction of the mandibular condyle fracture in all patients. The modified transparotid approach via the smaller, easily concealed parotid mini-incision is minimally invasive and achieves anatomical reduction and rigid internal fixation with a simplified procedure that directly exposes the fracture site. Study results showed that this procedure is safe and feasible for treating mandibular condyle fracture, and offers a short operative path, protection of the facial nerve and satisfactory aesthetic outcomes.  相似文献   

5.
Maxillofacial fractures in the elderly: a comparative study   总被引:2,自引:0,他引:2  
Previous maxillofacial trauma research has dealt primarily with facial bone fractures in the general population. Very few studies have specifically addressed maxillofacial fractures in the elderly. We compared 45 elderly (65 years of age or older) and 201 younger adult (16 to 64 years of age) patients admitted to our hospital with maxillofacial fractures. The percentage of patients admitted with nasal bone fractures was much greater in the elderly population, while mandibular fractures were more common in the adult group. Motor vehicle accidents accounted for over half the injuries in both groups, while falls were more prevalent in the elderly. Management of the elderly patient may be complicated by their associated injuries or underlying medical problems, perhaps partially accounting for their longer median length of hospital stay. The elderly are a unique subpopulation of maxillofacial fracture patients and deserve further study regarding their injuries and optimal methods for treatment.  相似文献   

6.
Between 1978 and 1984, 558 patients with complex facial fractures have been treated. One hundred and seventy-one of these patients have had complex Le Fort fractures of the maxilla. In this group of patients, the importance of direct anatomic reconstruction of the anterior maxillary buttresses has been assessed. Complete exposure of the injured buttresses will facilitate assessment of the exact fracture pattern. Direct fixation of the medial and lateral maxillary buttresses on each side, in combination with immediate bone-graft reinforcement or replacement of comminuted or missing buttresses, will facilitate the reconstruction of even the most severely injured maxilla in one stage. This approach is combined with similar reconstructive techniques in other areas of the craniofacial skeleton. Associated mandibular fractures are managed with rigid internal fixation utilizing A-O techniques. The use of these techniques dramatically facilitates airway management and simplifies the treatment of the edentulous patient, the patient with bilateral condylar neck fractures, and those patients with sagittal splitting of the maxilla and palate. The use of both internal craniofacial suspension wires and external craniofacial suspension devices has become largely unnecessary, and reconstruction of even the most complex injuries in one stage with minimal complications and secondary deformities is made possible.  相似文献   

7.
Objective: The occurrence of trauma in older people is well‐documented; however the incidence of maxillofacial trauma is scarcely reported. Therefore, the objective of this study is to determine the causes and consequences of maxillofacial trauma in older people. Design: A five‐year (March 95 ‐ March 2000) retrospective study was earned out of all patients over the age of 65 years with facial trauma presenting to Accident and Emergency Department (A&E). The information was collected using the medical notes and discharge summaries. Setting: The Departments of A&E and Maxillofacial Surgery. Subjects: A total of 42 patients' records were examined for study related data. Results: A total of 42 patients were seen during the study period. Thirty‐six gave a history of a fall, of which 15 had tripped, 5 had slipped, 3 resulted from a Transient Ischaemic Attack (TIA), 1 as a result of alcohol abuse, in 1 a prosthetic knee gave way and 11 gave no cause for the fall. Of the remaining 6 patients. 5 were assaulted and 1 had a wardrobe fall on top of him. The majority of the falls occurred during the winter months. Maxillofacial injuries were noted in 27 of the 42 patients. Sixteen patients had cheekbone fractures, 8 mandibular fractures, 2 midface and 1 orbital complex fracture. Twenty‐five percent of cheekbone fractures and 50% of mandibular fractures were treated surgically. Medical history was noted in 27 patients. Conclusions: This study clearly demonstrates the majority of the facial trauma in the older people can be treated conservatively unless the patients complain of functional problems.  相似文献   

8.
目的:本研究通过观察微创锁定钢板接骨术治疗老年股骨近端粉碎骨折临床效果,旨在找出最佳治疗方式。方法:自2007年12月~2010年03月,应用股骨近端锁定加压钢板治疗老年股骨近端粉碎骨折23例。记录术中出血量、手术时间,术后并发症、骨折愈合时间及最后一次随访时功能恢复情况。结果:骨折临床愈合时间为12~28周,平均16周。除1例患者髋内翻畸形,1例锁定加压钢板断裂外,其他患者均达到骨性愈合。结论:股骨近端锁定钢板具有创伤小、固定可靠、骨折愈合快、功能恢复满意的特点,尤其适用于老年股骨近端粉碎骨折。  相似文献   

9.
To develop an understanding of the expected functional outcomes after facial trauma, a retrospective cohort study of patients with complex facial fractures was conducted. A cohort of adults aged 18 to 55 years who were admitted to the R. Adams Cowley Shock Trauma Center between July of 1986 and July of 1994 for treatment of a Le Fort midface fracture (resulting from blunt force) was retrospectively identified.Outcomes of interest included measures of general health status and psychosocial well being in addition to self-reported somatic symptoms. General health status was ascertained using the Medical Outcomes Study 36-Item Short Form Health Survey (SF-36). The Body Satisfaction Scale was used to define patient concerns about altered body image and shape. To determine whether complex maxillofacial trauma and facial fractures contributed to altered social interactions, the Social Avoidance and Distress scale was used. In addition, information about a patient, his or her injury, and its treatment were ascertained from the medical records.Using the methods described above, 265 patients with Le Fort fractures were identified. These individuals were matched to a similar group of 242 general injury patients. A total of 190 of the Le Fort patients (72 percent of those eligible for the study) and 144 (60 percent) general injury patients were successfully located, and long-term interview data were acquired.Le Fort fracture patients as a group had similar health status outcomes when compared with the group of general injury patients. However, when outcomes were examined by the complexity of the Le Fort fracture, the authors found that study subjects with severe, comminuted Le Fort injuries (group D) had significantly lower SF-36 scores (worse outcomes) for the two dimensions related to role limitations: role limitations due to physical problems and role limitations due to emotional problems (p < 0.05). SF-36 scores for all other dimensions except physical function were also lower for comminuted versus less complex Le Fort fractures, although differences were not statistically significant.Specifically, there was a direct relationship between severity of facial injury and patients reporting work disability. Of group C and D Le Fort patients (severely comminuted fractures) only 55 and 58 percent, respectively, had returned to work at the time of follow-up interview. These figures are significantly lower than the back-to-work percentage of patients with less severe facial injury (70 percent).When study participants were asked if they were experiencing specific somatic symptoms at the time of the interview that they had not experienced before the injury, a significantly larger percent of the Le Fort fracture patients (compared with the general injury patients) responded in the affirmative. Differences between the Le Fort fracture and general injury groups were statistically significant (p < 0.05) for all 11 symptoms.The percentage of patients reporting complaints increased with increasing complexity of facial fracture in the areas of visual problems, alterations in smell, difficulty with mastication, difficulty with breathing, and epiphora, and these differences reached statistical significance.Patients sustaining comminuted Le Fort facial fractures report poorer health outcomes than patients with less severe facial injury and substantially worse outcomes than population norms. It is also this severely injured population that reports the greatest percentage of injury-related disability, preventing employment at long-term follow-up. The long-term goal of centralized tertiary trauma treatment centers must be to return the patient to a productive, active lifestyle.  相似文献   

10.
Toward CT-based facial fracture treatment   总被引:2,自引:0,他引:2  
Facial fractures have formerly been classified solely by anatomic location. CT scans now identify the exact fracture pattern in a specific area. Fracture patterns are classified as low, middle, or high energy, defined solely by the pattern of segmentation and displacement in the CT scan. Exposure and fixation relate directly to the fracture pattern for each anatomic area of the face, including frontal bone, frontal sinus, zygoma, nose, nasoethmoidal-orbital region, midface, and mandible. Fractures with little comminution and displacement were accompanied by subtle symptoms and required simple treatment; middle-energy injuries were treated by standard surgical approaches and rigid fixation. Highly comminuted fractures were accompanied by dramatic instability and marked alterations in facial architecture; only multiple surgical approaches to fully visualize the "buttress" system provided alignment and fixation. Classification of facial fractures by (1) anatomic location and (2) pattern of comminution and displacement define refined guidelines for exposure and fixation.  相似文献   

11.
目的:探讨微型钛板联合颌间牵引钉内固定术治疗颌骨骨折的临床效果及其在临床的安全性。方法:随机选取颌骨骨折患者共60例,将上述患者随机平均分成对照组与观察组。分别给予与单纯微型钛板坚固内固定治疗和微型钛板联合颌间牵引钉内固定术治疗方法。分析比较这两组患者4周内的临床治疗效果及安全性。结果:术后4周两组间临床治疗效果比较显示:采取微型钛板联合颌间牵引钉内固定术治疗的观察组治疗效果明显好于给予单纯微型钛板坚固内固定治疗的对照组。观察组总有效率为87%,对照组总有效率为53.3%,差异有统计学意义(P0.05).两组手术过程均顺利实施,患者术后均无严重并发症发生,术后恢复情况较好,经比较两组术后不良反应的差异无统计学意义(P0.05)。结论:微型钛板联合颌间牵引钉内固定术是治疗颌骨多发骨折有效安全方法。  相似文献   

12.
The patterns of midface fractures were related to postoperative computed tomography scans and clinical results to assess the value of ordering fracture assembly in success of treatment methods. A total of 550 midface fractures were studied for their midface components and the presence of fractures in the adjacent frontal bone or mandible. Preoperative and postoperative computed tomography scans were analyzed to generate recommendations regarding exposure and postoperative stability related to fracture pattern and treatment sequence, both within the midface alone and when combined with frontal bone and mandibular fractures. Large segment (Le Fort I, II, and III) fractures were seen in 68 patients (12 percent); more comminuted midface fracture combinations were seen in 93 patients (17 percent). Midface and mandibular fractures were seen in 166 patients (30 percent). Midface, mandible, and nasoethmoid fractures were seen in 38 patients (7 percent). Frontal bone and midface fractures were seen in 131 patients (24 percent). Split-palate fractures accompanied 8 percent of midface fractures. Frontal bone, midface, and mandibular fractures were seen in 54 patients (10 percent). The midface, because of weak bone structure and comminuted fracture pattern, must therefore be considered a dependent, less stable structure. Its injuries more commonly occur with fractures of the frontal bone or mandible (two-thirds of cases) and, more often than not (>60 percent), are comminuted. Comminuted and pan-facial (multiple area) fractures deserve individualized consideration regarding the length of intermaxillary immobilization. Examples of common errors are described from this patient experience.  相似文献   

13.
This study evaluates resorbable miniplate osteosyntheses in sagittal split osteotomies with major bone repositioning. Two resorbable 2.0-mm miniplate systems, MacroSorb (Macropore, San Diego, Calif.) and PolyMax (Synthes, Oberdorf, Switzerland), were compared consecutively. Amorphous 70:30 poly-L/DL-lactide copolymer plates sustain continuous hydrolysis through water penetration into the implant body during the first 6 months in situ. This breaks copolymer chains into smaller particles, which later become degraded through phagocytotic cells. Eighteen patients, 10 women and eight men, 16 to 57 years old (average, 27 years) were examined. They had severe dysgnathia caused by congenital craniofacial malformations, systemic disorders, trauma, amelogenesis imperfecta, oligodontia, and other conditions, and they needed five 8- to 10-mm and 13 major 10- to 12-mm repositions. Twelve sagittal split osteotomies were fixed with 12 MacroSorb plates in six patients, and 24 osteotomies were filled with 32 PolyMax plates in 12 patients. Ten mandibular plate, screw, hard-tissue, and soft-tissue specimens were taken at 3, 6, 9, or 12 months postoperatively in secondary operations (e.g., dental implant placement).Follow-up ranged from 4 to 19 months; all osteosyntheses reossified. Four patients showed proximal fragments rotated up to 5 mm sagittally anteriorly and nonaligned burr holes on the postoperative radiogram, suggesting plate fractures or screw pullout. When plate fracture was noted, guided occlusion was maintained 4 weeks after surgery. Occlusal, radiologic, and skeletal results remained stable. After starting fixation with two plates on each side, no more plate fractures were seen. In three other patients, minor skeletal relapses up to 3 mm horizontally resulted. Local histologic inspection of specimens showed thorough osseous union. Screw remnants embedded in bone made screw pullout unlikely; rather, screw-head or plate fractures were found as multiple degraded particles. Microscopy showed a chronic foreign body reaction. Two patients (11 percent) developed a sterile fistula 3 and 4 months after surgery, draining implant debris. Here, the biopsies showed a granulocytic infiltrate that subsided clinically after excisional biopsy. The assignment of MacroSorb plates followed by PolyMax plates was done in an otherwise unchanged treatment protocol. Comparison of the number of patients in each group with stable osteosyntheses and regular healing showed no significant differences by Fisher's exact test (p = 0.1516); therefore, the authors focused on the combined results for both treatments.The current osteosynthesis systems showed sufficient stability for mandibular fixation after sagittal split osteotomy and repositioning more than 10 mm distant when two plates were applied to each side; however, 27 percent of patients had complications, including relapses. Disadvantages were the cost, breakability, diameter, and need to place the screws vertically to the plate, necessitating a bent instrument or transbuccal incisions.  相似文献   

14.
G. J. Lloyd  T. A. Wright 《CMAJ》1977,116(6):626-628
Internal fixation of fractures has become increasingly important since the introduction of self-compressing implants. Rigidity of fixation thus ensured permits primary bone healing. Two types of self-compressing implants are available--screws and plates. The former produces compression between fracture fragments, the latter, along the long axis of the bone. Two common types of plates are the dynamic compression plate and the Osteo self-compressing plate. Use of self-compressing implants requires familiarity with the technique, a definite plan of operation, and strict asepsis and lack of infection in the patient. Indications for the technique include failure or unsuitability of closed reduction of fractures, care of associated serious soft-tissue injuries, and displaced intra-articular fractures. Use of self-compressing plates hastens rehabilitation, lessens joint stiffness and reduces the duration of hospitalization. The incidence of nonunion with self-compression techniques is lower than with traditional methods of fracture management.  相似文献   

15.
The medial canthal tendon and the fragment of bone on which it inserts ("central" fragment) are the critical factors in the diagnosis and treatment of nasoethmoid orbital fractures. The status of the tendon, the tendon-bearing bone segment, and the fracture pattern define a clinically useful classification system. Three patterns of fracture are appreciated: type I--single-segment central fragment; type II--comminuted central fragment with fractures remaining external to the medial canthal tendon insertion; and type III--comminuted central fragment with fractures extending into bone bearing the canthal insertion. Injuries are further classified as unilateral and bilateral and by their extension into other anatomic areas. The fracture pattern determines exposure and fixation. Inferior approaches alone are advised for unilateral single-segment injuries that are nondisplaced superiorly. Superior and inferior approaches are required for displaced unilateral single-segment injuries, for bilateral single-segment injuries, and for all comminuted fractures. Complete interfragment wiring of all segments is stabilized by junctional rigid fixation. All comminuted fractures require transnasal wiring of the bones of the medial orbital rim (medial canthal tendon-bearing or "central" bone fragment). If the fracture does not extend through the canthal insertion, the canthus should not be detached to accomplish the reduction.  相似文献   

16.
This study characterizes the surgically treated patient population suffering from orbital floor fractures by use of current data from a large series consisting of 199 cases taken from a nonurban setting. Data were gathered through a retrospective chart review of patients surgically treated for orbital floor fractures at the University of Michigan Health System, collected over a 10-year period. Data regarding patient demographics, signs and symptoms of presentation, cause of injury, nature of injury, associated facial fractures, ocular injury, and associated nonfacial skeleton trauma were collected. In total, there were 199 cases of orbital floor fractures among 189 patients. Male patients outnumbered female patients by a 2:1 ratio and were found to engage in a wider range of behaviors that resulted in orbital floor fractures. Motor vehicle accidents were the leading cause of orbital floor fractures, followed by physical assault and sports-related mechanisms. The ratio of impure to pure orbital floor fracture was 3:1. The most common signs and symptoms associated with orbital floor fractures, in descending order, were periorbital ecchymosis, diplopia, subconjunctival hemorrhage, and enophthalmos. Associated facial fractures were found in 77.2 percent of patients, the most prevalent of which was the zygoma-malar fracture. Serious ocular injury occurred in 19.6 percent of patients, with globe rupture being the most prevalent, accounting for 40.5 percent of those injuries. There was a 38.1 percent occurrence of associated nonfacial skeletal trauma; skull fracture and intracranial injury were the most prevalent manifestations. Associated cervical-spine fractures were rare (0.5 percent). Statistical examination, using odds ratios and chi-squared analysis, demonstrated significant associations that have not previously been reported. Impure and pure orbital floor fractures revealed striking differences in several demographic aspects, including mechanism of injury, signs and symptoms of presentation, spectrum of associated trauma, and the severity of concomitant trauma.  相似文献   

17.
Treatment of mandible fractures using bioabsorbable plates   总被引:3,自引:0,他引:3  
Kim YK  Kim SG 《Plastic and reconstructive surgery》2002,110(1):25-31; discussion 32-3
This study evaluated the short-term outcome of treating fractures of the mandible with bioabsorbable plates. Sixty-nine fractures of the mandible in 49 patients were treated by open reduction and internal fixation using bioabsorbable plates and 2.4-mm, 2.0-mm, and 1.5-mm pretapped screws. The duration of intermaxillary fixation ranged from 0 to 23 days, with a mean of 4.6 days. Patients were evaluated for complications during the follow-up period, which ranged from 1 to 18 months. Six patients (12.2 percent) experienced complications. These included infection (four patients), premature occlusal contact (one patient), and temporomandibular disorder (one patient). Except for one case, all complications were minor and adequately managed with incision and drainage, elastic traction, physical therapy, and medication. Delayed infection (osteomyelitis) developed in a symphysis fracture and was treated by saucerization and antibiotics. The fracture line subsequently showed complete consolidation. Bioabsorbable plates can be selectively used for internal fixation in mandibular fractures, with the advantage that they do not need to be removed.  相似文献   

18.
目的:改进骨折接骨扳内固定技术.观察新型迭形接骨板临床效果。方法:选择四肢长管骨骨折患者165例(上肢骨折26例,下肢骨折139例),均采用新型迭形接骨板施行骨折内固定手术。结果:手术后平均随访1年4个月(5年7个月~51天),除5例(占3%)出现并发症外,其余骨折均愈合良好,很少发现接骨板和螺钉断裂、折弯和松动情况。结论:与传统接骨板比较,新型迭形接骨板结构设计新颖,力学原理独特,临床效果满意,并发症少,较好地改进了四肢长管骨(尤其是下肢)骨折接骨板内固定技术,值得推荐。  相似文献   

19.
Conventional bone plates are commonly used for surgical mandibular fracture fixation. Improper alignment between bone segments, however, can result in malocclusion. Current methods of fixation require a surgeon to visually align segments of bone and affix a metal plate using bone screws, after which little can be done to adjust alignment. A method of adjusting fracture alignment after plate placement, without screw removal, presents an improvement over costly and risky revision surgery. A modified bone plate has been designed with a deformable section to give surgeons the ability to reduce misalignments at the fracture site. The mechanics of deformation for various adjustment mechanisms was explored analytically, numerically, and experimentally to ensure that the adjustable plate is comparable to conventional bone plates. A static force of 358.8 N is required to deform the adjustable bone plate, compared with predicted values of 351 N using numerical simulation and 362 N using a simple beam theory. Dynamic testing was performed to simulate in vivo loading conditions and evaluate load-capacity in both deformed and un-deformed bone plates. Results indicate that bending stiffness of a rectangular bone plate is 709 N/mm, compared with 174 N/mm for an octagonal plate and 176 N/mm for standard plates. Once deformed, the rectangular and octagonal plates had a stiffness of 323 N/mm and 228 N/mm, respectively. Un-deformed and deformed adjustable bone plates have efficacy in bone segment fixation and healing.  相似文献   

20.
Orbital roof fractures in the pediatric population   总被引:2,自引:0,他引:2  
Twenty-three patients aged 3.3 +/- 1.6 years (mean +/- SD) presented between January of 1984 and September of 1987 with fronto-orbital trauma resulting in fractures of one (N = 20) or both (N = 3) orbital roofs. All patients had computed tomography (CT) with axial and coronal sections that revealed three fracture patterns of the orbital roof (nondisplaced, superiorly displaced, and inferiorly displaced fractures). Orbital dystopia was exhibited in 35 percent (N = 8) of the patients. Exophthalmos was noted in 61 percent (N = 14) of the patients. Only 30 percent of the patients (N = 7) sustained associated maxillofacial fractures. Eight percent of fractures exhibited orbital encephaloceles. All patients lacked frontal sinus pneumatization. The majority of children with orbital roof fractures do not exhibit concomitant facial fractures. CT utilizing both axial and coronal sections is valuable in defining the extent and pattern of the fracture as well as in identifying associated neurologic injuries. Large, displaced orbital roof fractures, which occurred in 3 of 13 patients with displaced fractures in our series, should undergo early reduction to avoid late development of encephalocele.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号