首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
A high-performance liquid chromatographic (HPLC) method for the simultaneous determination of flumequine and its metabolite 7-hydroxyflumequine in sheep plasma was described. The two compounds were extracted from 100 μl of plasma by liquid–liquid extraction. Aliquots (100 μl) were injected onto the HPLC system and separated on a LiChrospher Select B column with an isocratic system. The compounds were detected by fluorimetric detection for concentrations below 500 μg/l and by UV detection for the concentrations exceeding 500 μg/l. The range of the validated concentrations were 50 000 to 5 μg/l and 500 to 10 μg/l with mean recovery rates of 87±3% and 60±1% for flumequine and 7-hydroxyflumequine, respectively.  相似文献   

2.
A high-performance liquid chromatography (HPLC) analytical method for the determination of oxolinic acid and flumequine in Artemia nauplii is described. The samples were extracted and cleaned up by a solid-phase extraction (SPE) procedure using SPE C18 cartridges. Oxolinic acid and flumequine were determined by reversed-phase HPLC using a mobile phase of methanol–0.1 M phosphate buffer, pH 3 (45:55, v/v) and a UV detection wavelength of 254 nm. Calibration curves were linear for oxolinic acid in the range of 0.2–50 μg/g (r2=0.9998) and for flumequine in the range of 0.3–50 μg/g (r2=0.9994). Mean recoveries amounted to 100.8% and 98.4% for oxolinic acid and flumequine, respectively. The quantification limit was 0.2 μg/g for oxolinic acid and 0.3 μg/g for flumequine. Quantitative data from an in vivo feeding study indicated excellent uptake of both drugs by Artemia nauplii.  相似文献   

3.
Quinolones are a group of synthetic antibiotics that are widely used in veterinary medicine. Their residues may remain in tissues, milk, etc. intended for human consumption. The European Union fixes the maximum residue limits (MRLs) of veterinary medicinal products in foodstuffs of animal origin. Analytical methods are therefore needed to determine them in biological samples. In this study, we describe capillary isotachophoresis-capillary zone electrophoresis (ITP-CZE) to analyze three quinolones, enrofloxacin (ENR), ciprofloxacin (CPR) and flumequine (FLU), in pig plasma samples. We used solid-phase extraction with Oasis HLB cartridges as a sample pretreatment clean-up step. Capillary zone electrophoresis (CZE) requires low amounts of sample and is not as sensitive as one would wish. ITP-CZE is an easy way to increase the sample loadability and sensitivity. With this system sensitivity increases 40-fold. The detection limits for CPR, ENR and FLU were 70, 85 and 50 microg l(-1), respectively, which were lower than their MRLs in different kinds of samples. This method is simple and sensitive, and is therefore an alternative tool to the existing HPLC methods for analyzing the residuals of these quinolones in biological samples.  相似文献   

4.
A high-performance liquid chromatographic assay is described as a routine analytical method for the determination of fumagillin in rainbow trout muscle tissue. Muscle tissue samples (1 g) containing fumagillin were deproteinized with 8 ml of an acetonitrile-water mixture (2:6, v/v). The extracts were purified with a Bond Elut Octyl C8 cartridge column, washed with a water-methanol mixture (95:5, v/v; 4 ml) and fumagillin was eluted with acetonitrile (1 ml). Analytical separations were performed by reversed-phase HPLC with UV detection at 351 nm under gradient conditions. The mobile phase was acetonitrile-0.005 M tetrabutyl ammonium phosphate in water (pH 7.8). The assay is specific and reproducible within the fumagillin range of 20–1000 ng/g and recovery at 20 ng/g was 69.2%. Sample preparation involves the use of a robotic sample preparation system. Gravimetric validation of all operations enabled Good Laboratory Practices to be observed.  相似文献   

5.
A procedure is described for the determination of plasma catecholamines using reversed-phase, ion-pair high-performance liquid chromatography coupled with electrochemical detection. Optimisation of chromatographic conditions with respect to detector performance and adherence to procedures and precautions described, render the method applicable to both neurochemical research and routine clinical analysis. The limit of quantitative detection of the method was found to be approximately 30 pg per injection for individual catecholamines. A single chromatographic run, providing adequate resolution of each component, could be completed in approximately 12 min.  相似文献   

6.
The present work firstly described the enantioseparation and determination of flumequine enantiomers in milk, yogurt, chicken, beef, egg, and honey samples by chiral liquid chromatography‐tandem mass spectrometry. The enantioseparation was performed under reversed‐phase conditions on a Chiralpak IC column at 20°C. The effects of chiral stationary phase, mobile phase components, and column temperature on the separation of flumequine enantiomers have been studied in detail. Target compounds were extracted from six different matrices with individual extraction procedure followed by cleanup using Cleanert C18 solid phase extraction cartridge. Good linearity (R2>0.9913) was obtained over the concentration range of 0.125 to 12.5 ng g‐1 for each enantiomer in matrix‐matched standard calibration curves. The limits of detection and limits of quantification of two flumequine enantiomers were 0.015‐0.024 and 0.045‐0.063 ng g‐1, respectively. The average recoveries of the targeted compounds varied from 82.3 to 110.5%, with relative standard deviation less than 11.7%. The method was successfully applied to the determination of flumequine enantiomers in multiple food matrices, providing a reliable method for evaluating the potential risk in animal productions.  相似文献   

7.
A rapid, sensitive method for quantitative determination of octopamine (a biogenic amine found in both vertebrate and invertebrate nervous tissue) has been developed using reversed-phase high-performance liquid chromatography. The biogenic amine is extracted with perchloric acid from tissue homogenates and derivatized witho-phthalaldehyde (OPT) prior to chromatography. Separation of the fluorescent octopamine-OPT adduct from other biogenic amines was achieved using a Bondapak C18 reversed-phase column and isocratic elution with a methanol-(0.08 mol/liter) acetic acid (5050 by vol, pH 2.9) mobile phase. A variable wavelength fluorometer with an 8-l flow cell was used for detection (excitation 340 nm, 418 nm secondary filter). Linearity ranged from 500 pg to 30 ng injected onto the column. Recovery of internal standard added to tissue homogenates averaged 65.4% with a standard deviation of 3.1%. The method has been used for the determination of octopamine in ganglia ofAplysia californica.This work was supported by the Naval Medical Research and Development Command, National Naval Medical Center, Department of the Navy, Research Task No. ZF51.524.023.1007. The opinions and statements contained herein are the private ones of the authors and are not to be construed as official or reflecting the views of the Navy Department or the Naval Service at large.  相似文献   

8.
A high-performance liquid chromatographic method, based on a dynamic cation-exchange system was used for the determination of physostigmine in brain tissue extracts. The precision and detection limit of the method as well as the extraction efficiency were established. The distribution of physostigmine over several parts of the brain after intravertebral application is reported.  相似文献   

9.
Cortisol and catecholamines are major physiological markers of human stress. In order to establish a fully automated assay system for both cortisol and catecholamines in saliva, which can be sampled without imposing stress, the previously developed system for salivary cortisol [Okumura et al., J. Chromatogr. B, 670 (1995) 11] was modified. The practical sensitivity was around 0.1 pmol ml−1 for norepinephrine and epinephrine and 0.5 pmol ml−1 for dopamine. The established assay procedure provided R.S.D. values of 2∼3% and recoveries of 96∼104% at 0.5 pmol ml−1. Measurement of salivary catecholamines in more than 300 samples taken from about 50 healthy volunteers indicated that the normal values of norepinephrine and dopamine were very low, about 0.1 pmol ml−1 each. In contrast to cortisol, salivary catecholamine levels did not parallel those in plasma. Nevertheless, since levels of salivary catecholamines may reflect the sympathetic nerve activity in the salivary gland, they were assayed in volunteers making a scientific presentation before a large audience. Four out of eleven volunteers reported strong feelings of fear or anxiety, and their salivary catecholamine levels were about ten times higher than normal.  相似文献   

10.
An automated liquid chromatography system was developed to carry out the separation of an egg yolk immunoglobulin (IgY) using cation exchange media. Industrially separated egg yolk was diluted 10 times with distilled water, the pH adjusted to 5.5, and the water-soluble protein fraction separated from lipoproteins by sedimentation. The supernatant was filtered and then applied to a column packed with a cation exchanger within an automated liquid chromatography system. Different operating conditions were investigated using phosphate buffer in order to assess the effect on recovery and purity. Fractions as pure as 80% could be collected and a recovery of the chromatography step of about 65% was obtained for a purity of 60% using either a linear or step gradient. The overall recovery for the process was 34% if one-step dilution/extraction is used for lipoprotein separation by sedimentation, and 51% if two-step dillution/extraction is used. Further improvement of the yield to about 60% is possible using centrifugation for lipoprotein separation. The automated system confers many advantages, the key elements being the time savings and accurate control of the process. (c) 1992 John Wiley & Sons, Inc.  相似文献   

11.
The naturally occurring aliphatic polyamines and diamines can be separated with an improved automated procedure on a sulfonated-type ion-exchange column. Quantitative determinations can be carried out on 2–20 nmoles of each amine.In addition to the simple diamines, spermidine, and spermine, this procedure separates a number of naturally occurring derivatives, such as monoacetyl-1,4-diaminobutane, monoacetylspermidine, carbamyl-1,4-diaminobutane, 1,4-diamino-2-hydroxybutane, and glutathionylspermidine.The method can be used for a variety of biological materials, including urine, animal tissues, and bacterial extracts.  相似文献   

12.
A sensitive and rapid HPLC assay for determining tazobactam and piperacillin in fatty tissue and serum is described. While the common methods need liquid-liquid extraction before the injection in a automated column switching HPLC, the new method works by direct injection of the filtered tissue extract or diluted serum in a automated column switching HPLC without any other pre-treatment. This was performed by the use of a NH2-precolumn and enrichment/transfer at different pH-level. During the analyses, the NH2-precolumn was automatically regenerated with acetonitrile-water. The chromatogram peaks for piperacillin and tazobactam were identified by the retention time and quantified by peak area. The calibration curve was linear between 1 and 16 microg/ml. The quantification limit of tazobactam was about 1 microg/ml in fatty tissue extracts and in diluted serum (calculated for pure serum 2 microg/ml), respectively. For piperacillin it was less. The described procedure allows sample clean-up and determination of the antibiotic within 35 min. The chromatograms with this easy sample treatment had the same quantity of matrix peaks and in contrast to liquid-liquid extraction no loss of piperacillin. Because of the automatically rinsing of the NH2-precolumn during the chromatographic separation, more than 50 different biological samples could be measured with one NH2-precolumn without loss of performance.  相似文献   

13.
A highly sensitive assay for arylsulfatase A was developed using high-performance liquid chromatography with electrochemical detection. The retention time of the enzymatic product, p-nitrocatechol, on a reverse phase column was approximately 2.0 min. The assay was able to detect 0.43 pmol p-nitrocatechol in a 20-microliter ethanol extract of the reaction mixture. The coefficients of variation for seven determinations of the intra- and interassays were 9 and 8%, respectively. The levels of arylsulfatase A activity in human saliva samples and leukocyte and platelet lysates determined by this assay were within 6 and 11%, respectively, of the levels determined by a spectrophotometric assay. The high-performance liquid chromatography assay may have utility in measuring arylsulfatase A activity in biological samples with low activity or specific activity or in samples with compounds which interfere with the spectrophotometric assay.  相似文献   

14.
A novel and highly sensitive method has been developed for the determination of catecholamines [noradrenaline (NA), dopamine (DA), serotonin (5-HT) and their metabolites 5-hydroxyindoleacetic acid (5-HIAA) and homovanillic acid (HVA)] in brain tissue. The method uses isocratic reversed-phase HPLC with amperometric end-point detection. The calibration curve was linear over the range 10–150 pg on-column. The assay limits of detection for NA, DA, 5-HT, 5-HIAA and HVA were 3.8, 3.8, 6.8, 5 and 7.5 pg on-column, respectively. The mean inter- and intra-assay relative standard deviations (RSDs) over the range of the standard curve were less than 5%. The absolute recoveries averaged 99.1%, 99.5%, 97.7%, 99.5% and 98.8% for NA, DA, 5-HT, 5-HIAA and HVA, respectively.  相似文献   

15.
An automated high-performance liquid chromatographic method for the assay of 3',5'-cyclic AMP was developed using octylsilica. Total analysis time was 10.1 min, with cAMP eluting at 3 min. As little as 10 pmol of cyclic AMP could be detected by absorption at 260 nm. Peak height and area were linearly related to cyclic AMP concentration over at least two orders of magnitude. The analytical procedure gave good results in the assay of crude microsomal preparations of adenylate cyclase from both bovine brain and sea urchin eggs. The method was used to demonstrate that sea urchin adenylate cyclase is a Ca2+-activated enzyme.  相似文献   

16.
A liquid chromatography procedure is described for the determination of some estrogens using fluorescence detection. The estrogens are labeled by precolumn derivatization with 5-dimethylaminonaphthalene-1-sulfonylchloride (dansyl chloride) and chromatographed on a reversed-phase, C-18 column with a mobile phase consisting of methanol, water, and acetic acid. The eluted analytes are measured with a fluorescence detector using excitation and emission wavelengths of 350 and 540 nm, respectively. The chief advantage of this new procedure is its sensitivity, requiring smaller amounts of sample to detect and quantitate estrogens in biological materials. We could detect less than 400 pg of estriol. With our procedure, this corresponded to about 25 ng in the final reaction mixture, before derivatization. The use of smaller sample volumes could improve this limit. Linearity for dansylated estriol, estrone, and estradiol was excellent over the estrogen range below 100 μg in the sample. This corresponds to approximately 1.7 μg on the column. Within-run precision was better than 5% for the full extraction and derivatization procedure for estriol from pregnancy urine samples. Chromatography is complete within 10 min for dansylated estriol, estrone, and estradiol.  相似文献   

17.
Using the CNS of Lymnaea stagnalis a method is described for the rapid analysis of neurotransmitters and their metabolites using high performance liquid chromatography coupled with electrochemical detection. Tissue samples were homogenised in ice-cold 0.1 M perchloric acid and centrifuged. Using a C(18) microbore column the mobile phase was maintained at a flow rate of 100 microl/min and consisted of sodium citrate buffer (pH 3.2)-acetonitrile (82.5:17.5, v/v) with 2 mM decane-sulfonic acid sodium salt. The potential was set at +750 mV versus Ag|AgCl reference electrode at a sensitivity of 50 nA full scale deflection. The detection limit for serotonin was 11.86 ng ml(-1) for a 5 microl injection. Preparation of tissue samples in mobile phase reduced the response to dopamine and serotonin compared with perchloric acid. In addition it was found that the storage of tissue samples at -20 degrees C caused losses of dopamine and serotonin. As a result of optimising the sample preparation and mobile phase the total time of analysis was substantially reduced resulting in a sample preparation and assay time of 15-20 min.  相似文献   

18.
A high-performance liquid chromatography assay for hydroxyurea in human serum was developed based on a commercial colorimetric assay kit for urea (Sigma Diagnostics). Serum (0.5 ml), spiked with methylurea as an internal standard, was treated with 70% perchloric acid. Supernatant (0.2 ml) was combined with 0.7 ml of BUN acid reagent and 0.6 ml of BUN color reagent. The resulting colored reactant (100 μl) was analyzed on a 300×3.9 mm Bondclone 10 C18 column coupled with a UV–Vis detector, at 449 nm. The mobile phase was 13% acetonitrile in water. Retention times of colored derivatives of hydroxyurea and methylurea were 6.5 and 12.2 min, respectively. The log–log calibration curve was linear from 0.0065 to 1.31 mM. Average accuracy was 99.9±4.0% and the intra- and inter-day error of assay did not exceed 11%.  相似文献   

19.
A sensitive and reproducible fully automated method for the determination of amino acids in plasma based on reversed-phase high-performance liquid chromatography and o-phthaldialdehyde pre-column derivatization is described. A 5-μm Spherisorb ODS 2 column (125 × 3 mm I.D.) was selected for routine determination. Over 40 physiological amino acids could be determined within 49 min (injection to injection) and 48 samples could be processed unattended. The coefficients of variation for most amino acids in plasma were below 4%. We were also able to measure trace amounts of amino acids in plasma normally not detected in a routine analysis. The results obtained with the method described compared favourably with those of conventional amino acid analysis (r = 0.997) and were in excellent agreement with those of other laboratories (r = 0.999).  相似文献   

20.
A validated high-performance liquid chromatographic procedure employing ultraviolet detection for the analysis of diclofenac in human plasma is reported. The method is rapid and, coupled with column switching, leads to a sensitive, accurate and reproducible assay. The retention times of diclofenac and the internal standard (4′-methoxydiclofenac, CGP-4287) are 6.4 and 7.6 min, respectively. The peak height versus plasma concentration is linear over the range 5.0–2000 ng/ml with a detection limit below 2.5 ng/ml. The mean absolute recovery of diclofenac using the described assay is 96.5% (n = 24). The inter- and intra-day accuracy and precision are within 8.3% of the actual values for all concentrations investigated. Furthermore, this procedure is applied to assess the pharmacokinetics of a single 75-mg oral dose of diclofenac sodium.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号