首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A new method for determining facet loads during in vitro spine loading using strain gauges and a neural networks solution method was investigated. A test showed that the new solution method was more robust than and as accurate as a previously presented graphical solution method for computing facet loads using surface strain. The technique was subsequently utilized to assess facet loads at L1-L2 during flexibility testing [7.5Nm pure moments in flexion (FL), extension (EX), right and left axial rotation (AR), and right and left lateral bending (LB)], and stiffness testing (FL-EX with 400N compressive follower load) of six human lumbar spine segments (T12-L2). In contrast to other techniques, such as thin film sensors or pressure-sensitive film, the strain-gauge method leaves the facet joint capsule intact during data collection, presumably allowing more natural load transmission. During flexibility tests, the mean (+/-standard deviation) calculated facet loads (in N) were 46.1+/-41.3 (FL), 51.5+/-39.0 (EX), 70.3+/-43.2 (AR-contralateral side), 31.3+/-33.4 (AR-ipsilateral side), 30.6+/-29.1 (LB-contralateral side), and 32.0+/-44.4 (LB-ipsilateral side). During stiffness tests, the calculated facet loads were 45.5+/-40.4 (upright), 46.6+/-41.9 (full FL), and 75.4+/-39.0 (full EX), corresponding to an equivalent of 11.4%, 11.6%, and 18.8% of the compressive follower load (upright, full FL and EX, respectively). The error associated with this technique, which was below 11N for loads up to 125N, is comparable to that reported with other techniques. The new method shows promise for assessing facet load during in vitro spine testing, an important parameter when evaluating new implant systems and surgical techniques.  相似文献   

2.
Simplified loading modes (pure moment, compressive force) are usually applied in the in vitro studies to simulate flexion-extension, lateral bending and axial rotation of the spine. The load magnitudes for axial rotation vary strongly in the literature. Therefore, the results of current investigations, e.g. intervertebral rotations, are hardly comparable and may involve unrealistic values. Thus, the question 'which in vitro applicable loading mode is the most realistic' remains open. A validated finite element model of the lumbar spine was employed in two sensitivity studies to estimate the ranges of results due to published load assumptions and to determine the input parameters (e.g. torsional moment), which mostly affect the spinal load and kinematics during axial rotation. In a subsequent optimisation study, the in vitro applicable loading mode was determined, which delivers results that fit best with available in vivo measurements. The calculated results varied widely for loads used in the literature with potential high deviations from in vivo measured values. The intradiscal pressure is mainly affected by the magnitude of the compressive force, while the torsional moment influences mainly the intervertebral rotations and facet joint forces. The best agreement with results measured in vivo were found for a compressive follower force of 720N and a pure moment of 5.5Nm applied to the unconstrained vertebra L1. The results reveal that in many studies the assumed loads do not realistically simulate axial rotation. The in vitro applicable simplified loads cannot perfectly mimic the in vivo situation. However, the optimised values lead to the best agreement with in vivo measured values. Their consequent application would lead to a better comparability of different investigations.  相似文献   

3.
A technique is described for measuring load magnitude and resultant load contact location in the facet joint in response to applied loads and moments, and the technique applied to the canine lumbar spine motion segment. Due to the cantilever beam geometry of the cranial articular process, facet joint loads result in surface strains on the lateral aspect of the cranial articular process. Strains were quantified by four strain gages cemented to the bony surface of the process. Strain measured at any one gage depended on the loading site on the articular surface of the caudal facet and on the magnitude of the facet load. Determination of facet loads during in vitro motion segment testing required calibration of the strains to known loads of various magnitudes applied to multiple sites on the caudal facet. The technique is described in detail, including placement of the strain gages. There is good repeatability of strains to applied facet loads and the strains appear independent of load distribution area. Error in the technique depends on the location of the applied facet loads, but is only significant in nonphysiologic locations. The technique was validated by two independent methods in axial torsion. Application of the technique to five in vitro canine L2-3 motion segments testing resulted in facet loads (in newtons, N) of 74+ / -23 N (mean + / -STD) in 2 newton-meter, Nm, extension, to unloaded in flexion. Lateral bending resulted in loads in the right facet of 40+ / -32 N for 1 Nm right lateral bending and 54+ / -29 N for 1 Nm left lateral bending. 4 Nm Torsion with and without 100 N axial compression resulted in facet loads of 92+ / -27 N and 69+ / -19 N, respectively. The technique is applicable to dynamic and in vivo studies.  相似文献   

4.
The knee is one of the most frequently injured joints in the human body. A recent study suggests that axial compressive loads on the knee may play a role in injury to the anterior cruciate ligament (ACL) for the flexed knee, because of an approximate 10 degrees posterior tilt in the tibial plateau (J. Orthop. Res. 16 (1998) 122-127). The hypothesis of the current study was that excessive axial compressive loads in the human tibio-femoral (TF) joint would cause relative displacement and rotation of the tibia with respect to the femur, and result in isolated injury to the ACL when the knee is flexed to 60 degrees , 90 degrees or 120 degrees . Sixteen isolated knees from eleven fresh cadaver donors (74.3+/-10.5 yr) were exposed to repetitive TF compressive loads increasing in intensity until catastrophic injury. ACL rupture was documented in 14/16 cases. The maximum TF joint compressive force for ACL failure was 5.1+/-2.1 kN for all flexion angles combined. For the 90 degrees flexed knee, the injury occurred with a relative anterior displacement of 5.4+/-3.8mm, a lateral displacement of 4.1+/-1.4mm, and a 7.8+/-7.0 degrees internal rotation of the tibia with respect to the femur.  相似文献   

5.
The effects of the rib cage on thoracic spine loading are not well studied, but the rib cage may provide stability or share loads with the spine. Intervertebral disc pressure provides insight into spinal loading, but such measurements are lacking in the thoracic spine. Thus, our objective was to examine thoracic intradiscal pressures under applied pure moments, and to determine the effect of the rib cage on these pressures. Human cadaveric thoracic spine specimens were positioned upright in a testing machine, and Dynamic pure moments (0 to ±5 N·m) with a compressive follower load of 400 N were applied in axial rotation, flexion - extension, and lateral bending. Disc pressures were measured at T4-T5 and T8-T9 using needle-mounted pressure transducers, first with the rib cage intact, and again after the rib cage was removed. Changes in pressure vs. moment slopes with rib cage removal were examined. Pressure generally increased with applied moments, and pressure-moment slope increased with rib cage removal at T4-T5 for axial rotation, extension, and lateral bending, and at T8-T9 for axial rotation. The results suggest the intact rib cage carried about 62% and 56% of axial rotation moments about T4-T5 and T8-T9, respectively, as well as 42% of extension moment and 36–43% of lateral bending moment about T4-T5 only. The rib cage likely plays a larger role in supporting moments than compressive loads, and may also play a larger role in the upper thorax than the lower thorax.  相似文献   

6.
Coupled axial tibial rotation in response to an anterior tibial load has been used as a common diagnostic measurement and as a means to load the ligamentous structures during laboratory tests. However, the exact location of the point of application of these loads as well as the corresponding sensitivity of the coupled tibial rotation to this point can have an effect on the function of the soft tissues at the joint. Therefore, the purpose of this study was to determine the effects of four different points of application of the anterior tibial load on the anterior tibial translation and coupled axial tibial rotation. The four points include: (1) geometric point - midway between the collateral ligament insertion sites on the tibia, (2) clinical point - a position that attempts to simulate clinical diagnostic tests, (3) medial point - a position medial to the geometric point and (4) lateral point - a position lateral to the clinical point. A robotic/universal force-moment sensor testing system was used to apply the anterior tibial load at the four points of application and to record the resulting joint motion. Anterior tibial translation in response to an anterior tibial load of 100N was found not to vary between the four points of application of the anterior tibial load at all flexion angles examined. However, internal tibial rotation was found for the lateral point (13+/-10 degrees at 30 degrees of knee flexion) in all specimens and clinical point (8+/-10 degrees at 30 degrees of knee flexion) while external rotation resulted when the load was applied at the medial point (-8+/-7 degrees at 30 degrees of knee flexion). Both internal and external tibial rotations occurred throughout the range of flexion when the tibial load was applied at the geometric point. The results suggest that the clinical point should be used as the point of application of the anterior tibial load whenever clinical examinations are simulated and multi-degree-of-freedom joint and soft tissue function are examined.  相似文献   

7.
This study determined in-vitro anterior cruciate ligament (ACL) force patterns and investigated the effect of external tibial loads on the ACL force patterns during simulated weight-bearing knee flexions. Nine human cadaveric knee specimens were mounted on a dynamic knee simulator, and weight-bearing knee flexions with a 100N of ground reaction force were simulated; while a robotic/universal force sensor (UFS) system was used to provide external tibial loads during the movement. Three external tibial loading conditions were simulated, including no external tibial load (termed BW only), a 50N anterior tibial force (ATF), and a 5Nm internal rotation tibial torque (ITT). The tibial and femoral kinematics was measured with an ultrasonic motion capture system. These movement paths were then accurately reproduced on a robotic testing system, and the in-situ force in the ACL was determined via the principle of superposition. The results showed that the ATF significantly increased the in-situ ACL force by up to 60% during 0-55 degrees of flexion, while the ITT did not. The magnitude of ACL forces decreased with increasing flexion angle for all loading conditions. The tibial anterior translation was not affected by the application of ATF, whereas the tibial internal rotation was significantly increased by the application of ITT. These data indicate that, in a weight-bearing knee flexion, ACL provides substantial resistance to the externally applied ATF but not to the ITT.  相似文献   

8.
A linear optimization model was formulated using a semi-experimental protocol to estimate the forces in the spinal elements of a lumbar motion segment subjected to an extension or lateral bending moment with and without a 120 N compressive preload. A morphometer was used to acquire the three-dimensional locations of the disk center, facet centers and ligament origin and insertion sites with the specimen in a "neutral" position. The relative motion of the superior vertebra, under the loading conditions tested, was monitored using a Selspot II system. These data allowed the formulation of the static equilibrium equations for the superior vertebra at each of the loading conditions mentioned above. A linear optimization technique was used, along with a suitable cost function, to find an optimum solution for the set of equations and imposed constraints. Results showed that for 6.9 Nm of extension moment, each facet carried a load of 52 N, with the disk carrying an axial tensile load of 104 N. At the 6.9 Nm extension moment coupled with 120 N preload, each facet carried a load of 77.2 N and the disk an axial tensile load of 37 N. In right lateral bending, with and without preload, the load was distributed among the right facet, the disk, the left ligamentum flavum and the left capsular ligament. At the 6.9 Nm load step without preload the right facet carried an axial load of 127.01 N with the disk carrying an axial compressive load of 7.8 N. Ligament forces for this step for the left ligamentum flavum and capsular ligament, respectively, were 61.03 N and 65.14 N. The addition of 120 N of preload reduced the load on the right facet to 83.5 N. The compressive load in the disk increased to 107.5 N. The corresponding ligament forces were 43.2 N (left ligamentum flavum) and 50.7 N (left capsular ligament).  相似文献   

9.
The effect of loading rate on specimen calibration was investigated for an implantable force sensor of the two-point loading variety. This variety of sensor incorporates a strain gage to measure the compressive load applied to the sensor due to tensile loading in a soft tissue specimen. The Achilles tendon in each of four human cadaveric lower extremities was instrumented with a force sensor and then loaded in tension using a materials testing machine. Each specimen was tensile tested at three different displacement rates, 0.25, 2.5 and 12.7 cm s(-1), corresponding with mean loading rates of 33.8, 513.2, and 2838.6 N s(-1), respectively. A calibration curve relating the force sensor signal and applied tendon tension was generated for each specimen/ displacement rate combination. For each specimen, calibration curves were compared by calculating an RMS error for the entire data set (eRMS = 1.6% of the full load value) and a coefficient of determination, R2, of a curve fit through all of the data (R2 = 99.6%). Over the range of rates tested, no measurable change in sensor sensitivity due to loading rate was observed. Hysteresis for all displacement rates was on the order of 2.4%.  相似文献   

10.
The mechanical coupling behaviour of the thoracic spine is still not fully understood. For the validation of numerical models of the thoracic spine, however, the coupled motions within the single spinal segments are of importance to achieve high model accuracy. In the present study, eight fresh frozen human thoracic spinal specimens (C7-L1, mean age 54 ± 6 years) including the intact rib cage were loaded with pure bending moments of 5 Nm in flexion/extension (FE), lateral bending (LB), and axial rotation (AR) with and without a follower load of 400 N. During loading, the relative motions of each vertebra were monitored. Follower load decreased the overall ROM (T1-T12) significantly (p < 0.01) in all primary motion directions (extension: −46%, left LB: −72%, right LB: −72%, left AR: −26%, right AR: −26%) except flexion (−36%). Substantial coupled motion was found in lateral bending with ipsilateral axial rotation, which increased after a follower load was applied, leading to a dominant axial rotation during primary lateral bending, while all other coupled motions in the different motion directions were reduced under follower load. On the monosegmental level, the follower load especially reduced the ROM of the upper thoracic spine from T1-T2 to T4-T5 in all motion directions and the ROM of the lower thoracic spine from T9-T10 to T11-T12 in primary lateral bending. The facet joints, intervertebral disc morphologies, and the sagittal curvature presumably affect the thoracic spinal coupled motions depending on axial compressive preloading. Using these results, the validation of numerical models can be performed more accurately.  相似文献   

11.
Methods were developed to measure intervertebral disc pressure using optical fibre-Bragg gratings (FBGs). The FBG sensor was calibrated for hydrostatic pressure in a purpose-built apparatus and the average sensitivity was determined to be -5.7 +/- 0.085 pm/MPa (mean +/- SD). The average coefficient of determination (r(2)) for the calibration data was 0.99, and the average hysteresis of the sensor was 2.13% of full scale. The FBG was used to measure intradiscal pressure response to compressive load in five lumbar functional spine units. The pressure measured by the FBG sensor varied linearly with applied compressive load with coefficients of determination ranging from 0.84 to 0.97. The FBG sensor's sensitivity to compressive load ranged from 0.702 +/- 0.043 kPa/N (mean +/- SD) in a L1-L2 specimen, to 1.07 +/- 0.069 kPa/N in a L4-L5 specimen. These measurements agree with those of previous studies in lumbar spines. Two strain gauge pressure sensors were also used to measure intradiscal pressure response to compressive load. The measured pressure sensitivity to load ranged from 0.251 kPa/N (L4-L5) to 0.850 kPa/N (L2-L3). The average difference in pressure sensitivity to load between Sensors 1 and 2 was 12.9% of the value for Sensor 1, with a range from 1.1% to 20.4%, which suggests that disc pressure was not purely hydrostatic. This may have contributed to the difference between the responses of the FBG and strain gauge sensors.  相似文献   

12.
Several investigators have analysed the compressive load bearing properties of the knee. Careful review of these force/displacement data showed considerable variation, with some investigators reporting displacements 12-15 x higher than others for nearly identical testing conditions using the same animal model. In this study, we sought to determine if this variability was inherent in the tibiofemoral joint or if differences in experimental methodology explained the variation. Compressive force/displacement curves were obtained from 39 normal canine tibiofemoral specimens mounted in a universal testing machine. Two commonly reported methods of measuring compressive displacement were used simultaneously. The testing machine crosshead displacement was used as one measure of displacement of the joint. The other method consisted of extensometers mounted to bone at the joint line. Resultant joint rotation in the parasagittal plane was also measured. Using either approach, we found comparatively little variation among the 39 specimens tested. However, the crosshead displacement measurements diverged from the extensometer measurements as the compressive load increased. At 770 N, the crosshead measurement was nearly twice the extensometer displacement. Further analysis showed that the compliances differed by a uniform amount. Parasagittal joint rotation, as measured by the extensometers, was minimal--less than one half of one degree. Although our loading fixtures were expected to be rigid under the loads used, these data suggest that the deformation of the bone and loading fixtures was responsible for the differences we observed, and may be responsible for the variation in compressive displacement results among several published studies. A model is presented which uses a simple elastic element to represent this deformation.  相似文献   

13.
This study investigated the effect of hamstring co-contraction with quadriceps on the kinematics of the human knee joint and the in-situ forces in the anterior cruciate ligament (ACL) during a simulated isometric extension motion of the knee. Cadaveric human knee specimens (n = 10) were tested using the robotic universal force moment sensor (UFS) system and measurements of knee kinematics and in-situ forces in the ACL were based on reference positions on the path of passive flexion/extension motion of the knee. With an isolated 200 N quadriceps load, the knee underwent anterior and lateral tibial translation as well as internal tibial rotation with respect to the femur. Both translation and rotation increased when the knee was flexed from full extension to 30 of flexion; with further flexion, these motion decreased. The addition of 80 N antagonistic hamstrings load significantly reduced both anterior and lateral tibial translation as well as internal tibial rotation at knee flexion angles tested except at full extension. At 30 of flexion, the anterior tibial translation, lateral tibial translation, and internal tibial rotation were significantly reduced by 18, 46, and 30%, respectively (p<0.05). The in-situ forces in the ACL under the quadriceps load were found to increase from 27.8+/-9.3 N at full extension to a maximum of 44.9+/-13.8 N at 15 of flexion and then decrease to 10 N beyond 60 of flexion. The in-situ force at 15 was significantly higher than that at other flexion angles (p<0.05). The addition of the hamstring load of 80 N significantly reduced the in-situ forces in the ACL at 15, 30 and 60 of flexion by 30, 43, and 44%, respectively (p<0.05). These data demonstrate that maximum knee motion may not necessarily correspond to the highest in-situ forces in the ACL. The data also suggest that hamstring co-contraction with quadriceps is effective in reducing excessive forces in the ACL particularly between 15 and 60 of knee flexion.  相似文献   

14.
The envelope of passive knee joint motion   总被引:7,自引:2,他引:5  
The purpose of this study is to create an accurate experimental database for the passive (in vitro) freedom-of-motion characteristics of the human knee joint on a subject to subject basis, suitable for the verification and enhancement of mathematical knee-joint models. Knee-joint specimens in a six degree-of-freedom motion rig are moved through flexion under several combinations of external loads, including tibial torques, axial forces and AP-forces. Euler rotation angles and translation vectors, describing the relative, spatial motions of the joint are measured using an accurate Roentgen Stereo Photogrammetric system. Conceptually the joint is considered as a two degrees-of-freedom of motion mechanism (flexion-tibial rotation), whereby the limits of internal and external tibial rotation are defined at torques of +/- 3 Nm. The motion pathways along these limits are defined as the envelopes of passive knee joint motion. It is found that these envelope pathways are consistent and hardly influenced by additional axial forces up to 300 N and AP-forces of 30 N. Within the envelope of motion, however, the motion patterns are highly susceptible to small changes in the external load configuration. It is shown that the external tibial rotation during extension ('screw-home mechanism') is not an obligatory effect of the passive joint characteristics, but a direct result of the external loads. Anatomical differences notwithstanding, the inter-individual discrepancies in the motion patterns of the four specimens tested, showed to be relatively small in a qualitative sense. Quantitative differences can be explained by small differences in the alignment of the coordinate systems relative to the joint anatomy and by differences in rotatory laxity.  相似文献   

15.
Compression on the lumbar spine is 1000 N for standing and walking and is higher during lifting. Ex vivo experiments show it buckles under a vertical load of 80-100 N. Conversely, the whole lumbar spine can support physiologic compressive loads without large displacements when the load is applied along a follower path that approximates the tangent to the curve of the lumbar spine. This study utilized a two-dimensional beam-column model of the lumbar spine in the frontal plane under gravitational and active muscle loads to address the following question: Can trunk muscle activation cause the path of the internal force resultant to approximate the tangent to the spinal curve and allow the lumbar spine to support compressive loads of physiologic magnitudes? The study identified muscle activation patterns that maintained the lumbar spine model under compressive follower load, resulting in the minimization of internal shear forces and bending moments simultaneously at all lumbar levels. The internal force resultant was compressive, and the lumbar spine model, loaded in compression along the follower load path, supported compressive loads of physiologic magnitudes with minimal change in curvature in the frontal plane. Trunk muscles may coactivate to generate a follower load path and allow the ligamentous lumbar spine to support physiologic compressive loads.  相似文献   

16.
In the present work, the load-bearing role of the facet joints in a lumbar I2-3 segment is quantitatively determined by means of a three dimensional nonlinear finite element program. The analysis accounts for both material and geometric nonlinearities and treats the facet articulation as a nonlinear moving contact problem. The disc nucleus is considered as an inviscid incompressible fluid and the annulus as a composite of collagenous fibres embedded in a matrix of ground substance. The spinal ligaments are modelled as a collection of nonlinear axial elements. The loadings consist of axial compression and sagittal plane shears and bending moments, acting alone or combined. The results show that in pure compression, the external axial force is transmitted primarily by the intervertebral disc. The facet joints carry only a small percentage of the force. However, the facet joints carry large forces in extension, whereas in small flexion they carry none. Addition of compression tends to increase these contact forces in extension while it has no effect on them in flexion. In extension, the forces on the facet joints are transmitted by both the articular surfaces and the capsular ligaments. Although in small flexion the facets carry no load, large contact forces are predicted to develop as the segment is flexed beyond 7-8 degrees. These forces are of the same magnitude as those computed under large extension rotation and are oriented nearly in the horizontal plane with negligible component in the axial direction. The horizontal components of the contact forces generated during articulation are often larger than the axial components which directly resist the applied compressive force. The axial components of the contact forces, therefore, grossly underestimate the total forces acting on the facets. The transfer of forces from one facet to the adjacent one occurs through distinct areas in flexion and in extension loadings. That is, on the superior articular surface, the contact area shifts from the upper tip in large flexion to the lower margin in extension. On the inferior articular surface, the contact area shifts from the upper and central regions in large flexion to the lower tip in extension.  相似文献   

17.
Contact area is often used to characterize the biomechanical properties of joints, especially in testing of injury and joint replacement. Several methods have been developed to measure contact area, including piezo-resistive thin-film arrays. The purpose of this study was to determine the accuracy with which one of these systems (Tekscan, Inc., South Boston, MA) could measure the contact area of flat-ended circular indenters of varying known sizes. Static loads ranging from 1000 to 7000 N were applied to four flat, circular indenters (1140, 2027, 3167, and 4560 mm(2)) and the contact areas were recorded with Tekscan 5076 sensor. Similar testing was carried out on a 4000 sensor. I-scan software (Tekscan Inc., South Boston, MA) was used to analyze the Tekscan-recorded area measurements. The Tekscan data were also post-processed to filter out sensel signal intensity values that were at least two standard deviations from the average sensel signal intensity values of the sensor matrix. Unprocessed Tekscan measurements with the 5076 sensor had area percent errors ranging from 5% to 27%. The filtering algorithm reduced most errors to less than 1%. Similar trends of improved accuracy with post-filtering were found with the 4000 sensor. While this method of thresholding out the sensels with the lowest signal intensity values may not work for all surfaces and indenter shapes, it provides a new approach to improve the accuracy of contact area measurements collected with the Tekscan system.  相似文献   

18.
The capacity to perform isometric and dynamic muscle contractions at different forces has been measured in two separate groups of subjects: 25 men and 25 women performed sustained isometric contractions of the knee-extensor muscles of their stronger leg to fatigue, at forces corresponding to 80%, 50% and 20% of the maximum voluntary force of contraction (MVC). The second experimental model involved a bilateral elbow-flexion weight lifting exercise. Eleven women and 12 men performed repetitions at loads corresponding to 90%, 80%, 70%, 60% and 50% of maximum load (1RM), at a rate of 10 X min-1 to the point of fatigue. Males were stronger (p less than 0.001) than females in both the static (675 +/- 120 N vs 458 +/- 80 N; mean +/- SD) and dynamic (409 +/- 90 N vs 190 +/- 33 N) contractions. Isometric endurance time of the males at a force corresponding to 20% of MVC was less than that of the females (180 +/- 51 s vs 252 +/- 56 s; p less than 0.001) but there was no difference between the sexes at 50% or 80% of MVC. Similarly, when the sexes were compared using dynamic elbow-flexion exercise, the female subjects were able to perform a greater number of repetitions than males at loads of 50% (p less than 0.005), 60% (p less than 0.001) and 70% (p less than 0.025) of 1RM, but there was no difference between the sexes at loads of 80% or 90% of 1RM.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

19.
Although muscles are assumed to be capable of stabilizing the spinal column in vivo, they have only rarely been simulated in vitro. Their effect might be of particular importance in unstable segments. The present study therefore tests the hypothesis that mechanically simulated muscle forces stabilize intact and injured cervical spine specimens. In the first step, six human occipito-cervical spine specimens were loaded intact in a spine tester with pure moments in lateral bending (+/- 1.5 N m), flexion-extension (+/- 1.5 N m) and axial rotation (+/- 0.5 N m). In the second step, identical flexibility tests were carried out during constant traction of three mechanically simulated muscle pairs: splenius capitits (5 N), semispinalis capitis (5 N) and longus colli (15 N). Both steps were repeated after unilateral and bilateral transection of the alar ligaments. The muscle forces strongly stabilized C0-C2 in all loading and injury states. This was most obvious in axial rotation, where a reduction of range of motion (ROM) and neutral zone to <50% (without muscles=100%) was observed. With increasing injury the normalized ROM (intact condition=100%) increased with and without muscles approximately to the same extend. With bilateral injury this increase was 125-132% in lateral bending, 112%-119% in flexion-extension and 103-116% in axial rotation. Mechanically simulated cervical spine muscles strongly stabilized intact and injured cervical spine specimens. Nevertheless, it could be shown that in vitro flexibility tests without muscle force simulation do not necessarily lead to an overestimation of spinal instability if the results are normalized to the intact state.  相似文献   

20.
A comparison between the dynamic compressive properties of human lumbar intervertebral joints when fresh and after a period of deep frozen storage was made. Physiologically relevant loads of -750 +/- 250 N were applied in axial compression with the joint constrained against bending, over a frequency range of 0.01-10 Hz. Frozen storage was found not to affect the compressive stiffness or hysteresis of the seven joints. The magnitude of the observed changes in mean values were small, less than 1% decrease in the compressive stiffness and less than 1% increase in hysteresis after deep frozen storage.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号