首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A simple method for simultaneous determination of androstenediol 3-sulfate (Adiol-3S) and dehydroepiandrosterone sulfate (DHEA-S) in human serum using isotope diluted liquid chromatography-electrospray ionization-ion trap-mass spectrometry (LC-ESI-ion trap-MS) was developed. After addition of deuterated internal standards ([2H5]Adiol-3S and [2H4]DHEA-S), human serum (100 microl) was deproteinized with acetonitrile and then applied to a solid-phase extraction cartridge, Oasis HLB. The obtained steroid sulfates fraction was washed with hexane and then analyzed by LC-ESI-MS operated in the negative ion mode. The quantification ranges of Adiol-3S and DHEA-S were 10-400 ng/ml and 0.05-8 microg/ml, respectively. The method does not require the chemical or enzymatic hydrolysis of the conjugates and purification with high-performance liquid chromatography, and shows satisfactory reproducibility and accuracy. The concentrations of these sulfates in the sera of healthy male volunteers (n=14) were 19.2-245.3 mg/ml (Adiol-3S) and 0.175-5.16 microg/ml (DHEA-S), and those of patients with prostate cancer (n=19) were 15.3-182.7 ng/ml (Adiol-3S; four samples, not detectable) and 0.110-2.421 microg/ml (DHEA-S).  相似文献   

2.
20 (R,S)-Ginsenoside-Rg2, an anti-shock agent, is prescribed as a racemate. To analyze simultaneously the enantiomers of 20 (R)-ginsenoside-Rg2 and 20 (S)-ginsenoside-Rg2 in plasma, a simple and reproducible high-performance liquid chromatographic (HPLC) method has been developed. The enantiomeric separation and determination were successfully achieved using a Diamonsil ODS C18 reversed-phase column (5 microm, 250 mm x 4.6 mm) with an RP18 (5 microm) guard column and a mobile phase of MeOH-aq. 4% H3PO4 (65:35, v/v, pH 5.1) with UV detection at 203 nm. Both enantiomers, 20 (R)-ginsenoside-Rg2 and 20 (S)-ginsenoside-Rg2, were well separated at 14.5 min and 13.6 min, respectively. The linear ranges of the standard curves were 2.0-250 microg/ml. The intra- and inter-day precision (R.S.D.) were 相似文献   

3.
A validated high-performance liquid chromatography method is described for the determination of scutellarin in rat plasma using a liquid-liquid extraction and ultraviolet (UV) absorbance detection. The separation used a Diamonsil ODS column (250 mm x 4.6mm i.d., 5 microm particle size) with an isocratic mobile phase consisting of methanol-acetonitrile-50mM dihydrogen ammonium phosphate buffer (22:15:63 (v/v/v), adjusted to pH 2.5 with 1M phosphoric acid). The ultraviolet detector operated at 335 nm. Plasma samples were extracted with ethyl acetate after acidification. The extraction recovery of scutellarin ranged from 68.1 to 80.5%. High selectivity and a low quantitation limit (0.050 microg/ml) were achieved. The linear range was 0.050-12.5 microg/ml, correlation coefficient r=0.9981. The method has a good reproducibility, R.S.D. values were below 7.9% for within-day and between-day precision. The method is simple, rapid, and applicable to preliminary pharmacokinetic studies of scutellarin in rats.  相似文献   

4.
Deltamethrin (DLM), [(S)-alpha-cyano-d-phenoxybenzyl-(1R,3R)-e-(2,2 dibromovinyl)-2,2-dimethylcyclo-propane-1-carboxylate], is a pyrethroid insecticide widely used in agriculture and households. There are several methods for analysis of DLM in biological fluids and tissues, but these methods are time consuming. They generally involve the extraction of DLM with lipid-soluble solvents such as n-pentane, n-hexane, diethylether or acetone, and subsequent evaporation of the solvent. A more rapid and sensitive high-performance liquid chromatography (HPLC) method to analyze DLM in plasma and tissues (liver, kidney, and brain) was developed and validated according to U.S. Food and Drug Administration (U.S. FDA) and International Conference on Harmonization (ICH) of Technical Requirements for Registration of Pharmaceuticals for Human Use guidelines. The limit of detection (S/N of 3/1) for DLM was 0.01 microg/ml for plasma, liver, kidney and brain. The method performances were shown to be selective for DLM and linear over the concentration range 0.01-20.0 microg/ml. For five replications of samples at 0.05, 0.1, 0.2, 1.5 and 4.0 microg/ml, intraday precision and accuracy values were in the range of 0.7-13.1% relative standard deviation (%R.S.D.) and 1.8-14.1%Error, respectively. Interday (n = 15) precision and accuracy values at 0.05, 0.1, 0.2, 1.5, and 4.0 microg/ml were in the range of 3.2-15.2% (%R.S.D.) and 3.7-14.8%Error, respectively. The absolute recoveries of DLM ranged from 93 to 103% for plasma, 95 to 114% for liver, 97 to 108% for kidney, and 95 to 108% for brain. This method can be quite useful for DLM pharmacokinetic and tissue distribution studies, for which multiple plasma and tissue samples have to be analyzed quickly with high reproducibility.  相似文献   

5.
Benzene is a human carcinogen and its metabolite, urinary trans,trans-muconic acid (ttMA), is a biomarker for risk assessment. However, most of the existing methods were not sensitive enough for monitoring of low level exposure. This paper describes a HPLC-UV method for ttMA determination with enhanced selectivity and sensitivity. A 30 mg OasisMAX cartridge was used to clean-up 50 microl of urine sample and gradient elution was performed on a Zorbax SB-C(18) column (30 degrees C). ttMA was detected at wavelength 263 nm using a UV diode array detector (DAD). The two mobile phases used were (A) 150 mM ortho-phosphoric acid containing of 9% (v/v) methanol; and (B) 125 mM ortho-phosphoric acid containing 30% (v/v) acetonitrile. The method was validated with 61 urine samples collected from non-occupationally benzene exposed individuals and 14 quality control specimens from an international quality assessment scheme. The urinary ttMA concentrations (mean+/-S.D.microg/g creatinine) were 90+/-34 for smokers (n=26), 49+/-39 for non-smokers (n=21) and 23+/-18 for non-smoking hospital staff (n=14). A correlation coefficient, r=0.99 was found with 14 external quality specimens for ttMA ranged from 0.4 to 6.8 mg/l. The recovery and reproducibility were generally over 90% and the detection limit was 5 microg/l.  相似文献   

6.
A new method of determining coenzyme Q10 in human plasma was developed based on column-switching high performance liquid chromatography (HPLC). CoQ10 was quantitatively extracted into 1-propanol with a fast one-step extraction procedure, after centrifugation, the supernatant was cleaned on an octadecyl-bonded silica column and then transferred to reversed-phase column by a column-switching valve. Determination of CoQ10 was performed on a reversed-phase analytical column with ultraviolet detection at 275 nm and the mobile phase containing 10% (v/v) isopropanol in methanol at a flow-rate of 1.5 ml/min. The sensitivity of this method allows the detection of 0.1 microg/ml CoQ10 in plasma (S/N=3). The linearity between the concentration and peak height is from 0.05 to 20 mg/l. The reproducibility (R.S.D.%) of the method is less than 2% (within day) and less than 3% (between day), the average recovery is 100.9 + 2.1%, it takes only 30 min to complete an analysis procedure, suitable for the determination of CoQ10 in human plasma especially for batch analysis in clinical laboratories. Finally, the method was applied to determine the plasma CoQ10 levels in healthy subjects, hyperthyroid and hypothyroid patients.  相似文献   

7.
A selective and sensitive high performance liquid chromatography-electrospray ionisation-mass spectrometry method has been developed for the determination of balofloxacin (BLFX) in human plasma. The sample preparation was a liquid-liquid extraction, and chromatographic separation was achieved with an Agilent ZORBAX 300SB C18 2.1 mm x 150 mm column using a mobile phase comprised of methanol-water (10 mM CH(3)COONH(4), pH 3.0)=40:60 (v/v). Standard curves were linear (r=0.9992) over the concentration range of 0.03-3 microg/ml and had good accuracy and precision. The within- and between-batch precisions were within 10% relative standard deviation (R.S.D.). The limit of detection (LOD) was 0.02 microg/ml. The validated HPLC-electrospray ionization (ESI)-MS method has been used successfully to study balofloxacin pharmacokinetics in healthy volunteers.  相似文献   

8.
The flavonoid compound mangiferin is found in the leaves, stem bark, fruit peels and root of Mangifera indica L. and in many other herbal species with many potential pharmacological properties. We have established an analytical method of mangiferin extracted from M. indica L. bark and Mangifera persiciformis C.Y. Wu et T.L. Ming leaves utilizing CZE. An electrolytic buffer containing 0.05 M borate buffer, pH 7.4 with methanol (1:0.3, v/v) was deemed suitable for mangiferin analysis. An ideal mangiferin electropherogram with a migration time at approximately 10.50 min was obtained. Repeatability tests showed that the R.S.D.s for both intra- and inter-day migration time and peak area for all manigferin sources tested were less than 4%. The linearity range of this method was 5-1000 microg/ml. The detection limit of this method was 1.5 microg/ml. Quantitative analysis of mangiferin was also performed with this method. The accuracy of quantitation at 10, 500 and 1000 microg/ml of control mangiferin were 99.00, 99.38 and 99.14%, respectively (n=10). The repeatability of quantitation (R.S.D.) was below 3%. Our results demonstrated that CZE is a simple and reliable method in mangiferin analysis and more studies are needed to detect other mangiferin resources, such as clinical biological samples, in pharmacology and pharmacokinetic studies.  相似文献   

9.
Iodixanol is a widely used iso-osmolar contrast medium agent. Similar to iohexol, it can also be a good exogenous marker for the measurement of glomerular filtration rate (GFR). This article describes the development and validation of an HPLC-UV method for quantification of iodixanol in human plasma. Internal standard, iohexol (20 microl, 1 mg/ml), and perchloric acid (30 microl, 20%, v/v) were added to plasma samples (300 microl), followed by neutralization with 10 microl potassium carbonate (5M). Samples were centrifuged and 10 microl of the supernatant was injected onto a C(18) EPS analytical column (3 microm particle size, 150 mm x 4.6 mm). The extraction method yielded >95% recovery for both iodixanol and iohexol. The mobile phase consisted of 0.1% (w/v) sodium formate buffer and acetonitrile. Iohexol and iodixanol peaks were eluted at approximately 5 and 9 min, respectively using a fast gradient method. The assay lower limit of detection was 2.0 microg/ml and lower limit of quantification was 10 microg/ml. The calibration curves, assessed in six replicates, were linear over an iodixanol concentration range of 10-750 microg/ml. Intra- and inter-day accuracy was >95% and precision expressed as % coefficient of variation was <10%. This method is simple, accurate, precise and robust and can potentially be used for iodixanol quantification in large-scale clinical studies.  相似文献   

10.
The binding properties of glucagon receptors were determined in plasma membranes isolated from liver of untrained (n = 6) and swimming endurance-trained Sprague-Dawley male rats (n = 7; 3 h/day, 5 days/wk, for 8 wk). Plasma membranes were purified from liver by aqueous two-phase affinity partitioning, and saturation kinetics were obtained by incubation of plasma membranes (10 microg of proteins/150 microl) with (125)I-labeled glucagon at concentrations ranging from 0.15 to 3.0 nM for 30 min at 30 degrees C. Saturating curve analysis indicated no difference in the affinity of glucagon receptors (0.57 +/- 0.06 and 0.77 +/- 0.09 nM in untrained and trained groups, respectively) but a significant higher glucagon receptor density in liver from untrained vs. trained rats (3.09 +/- 0.12 vs. 4.28 +/- 0.19 pmol/mg proteins). These results suggest that the reported increase in liver glucagon sensitivity in endurance-trained subjects (Drouin R, Lavoie C, Bourque J, Ducros F, Poisson D, and Chiasson J-L. Am J Physiol Endocrinol Metab 274: E23-E28, 1998) could be partly due to an increased glucagon receptor density in response to training.  相似文献   

11.
A reversed-phase high-performance liquid chromatographic method is described for the determination of betaxolol in human aqueous humour. Betaxolol and the internal standard metoprolol were extracted with cyclohexane and separated on a reversed-phase column (Luna C(18), 250 x 4.6 mm, 5 microm) with a mobile phase containing acetonitrile-phosphate buffer (40:60, v/v) at a flow-rate of 0.8 ml/min. The column effluent was monitored with a fluorescence detector at 227 nm (excitation) and 301 nm (emission). The retention times for metoprolol and betaxolol were 3.55 and 5.63 min, respectively. The recovery from aqueous humour was found to be 71.6% for betaxolol at 1.25 microg/ml. The within-day and day-to-day accuracy values were in the range of 96.17-105.2% for betaxolol at 0.1, 4 and 12 microg/ml (n=6), within-day and day-to-day precision values were less than 10% for betaxolol at the concentrations given above. The detection limit corresponding to the signal-to-noise ratio of 3:1 was 15 ng/ml. The presented method was suitable for measuring betaxolol levels in human aqueous humour samples obtained from patients after topical administration.  相似文献   

12.
A high-performance liquid chromatographic method using liquid-liquid extraction was developed for the determination of 1-(3-fluoro-4-hydroxy-5-mercaptomethyl-tetrahydrofuran-2-yl)-5-methyl-1H-pyrimidine-2,4-dione (l-FMAUS; I) in rat plasma and urine. A 100 microl aliquot of distilled water containing l-cysteine (100 mg/ml) was added to a 100 microl aliquot of biological sample. l-Cysteine was employed to protect binding between the 5'-thiol of I and protein in the biological sample. After vortex-mixing for 30s and adding a 50 microl aliquot of the mobile phase containing the internal standard (10 microg/ml of 3-aminophenyl sulfone), 1 ml of ethyl acetate was used for extraction. After vortex-mixing, centrifugation, and evaporating the ethyl acetate, the residue was reconstituted with a 100 microl aliquot of the mobile phase. A 50 microl aliquot was injected onto a C(18) reversed-phase column. The mobile phases, 50 mM KH(2)PO(4) (pH = 2.5):acetonitrile (85:15, v/v) for rat plasma and 50 mM KH(2)PO(4) (pH 2.5):acetonitrile:methanol (85:10:5, v/v/v) for urine samples, were run at a flow-rate of 1.2 ml/min. The column effluent was monitored by an ultraviolet detector set at 265 nm. The retention times for I and the internal standard were approximately 9.7 and 12.5 min, respectively, in plasma samples and the corresponding values in urine samples were 16.8 and 14.9 min. The quantitation limits of I in rat plasma and urine were 0.1 and 0.5 microg/ml, respectively.  相似文献   

13.
The aim of this study was to develop a rapid and sensitive HPLC method with UV detection for the estimation of imatinib from the plasma of patients with chronic myeloid leukemia (CML). The robustness of the method was checked by conducting first dose pharmacokinetics on blood samples from four patients who had been administered Gleevec (100 mg) in an oral dose. Samples were prepared in a simple and single step by precipitating the plasma proteins with methanol and injecting 50 microl aliquot from supernatant was subjected for analysis. Assay was conducted using a C8 column (250 mm x 4.6 mm, 5 microm particle size) under isocratic elution with 0.02 M potassium dihydrogen phosphate-acetonitrile (7:3, v/v) at a flow rate of 1 ml/min and detected using photodiode array at 265 nm. Calibration plots in spiked plasma were linear in a concentration range of 0.05-25 microg/ml. The inter and intra-day variation of standard curve was <4% (R.S.D.). This method could be a simple and quick method for the estimation of imatinib from the patient's plasma.  相似文献   

14.
A sensitive radioreceptor assay has been used to measure in vitro 1,25-dihydroxyvitamin D3 (1,25-(OH)2D3) synthesis in vitamin D-replete rats. Incubation of kidney cortical slices with 25-hydroxyvitamin D3 produced a product which co-migrated on high performance liquid chromatography with authentic 1,25(OH)2D3 in two different solvent systems and displaced 1,25(OH)2D3 from its intestinal receptor. In addition, mass spectral analysis of the product produced a mass fragmentation consistent with that of authentic 1,25(OH)2D3. Endogenous renal cortical 1,25(OH)2D3 content in phosphate-deprived rats averaged 1.1 +/- 0.3 pmol/g (n = 11), which was significantly greater than the renal cortical 1,25(OH)2D3 content of age-matched rats eating a normal diet which averaged 0.44 +/- 0.21 pmol/g (n = 8, p less than 0.001). After incubation, net 1,25(OH)2D3 synthesis in renal slices from phosphate-deprived rats averaged 51 pmol/g/h, about 13-fold greater than the mean of 3.8 pmol/g/h observed in renal slices from rats eating the normal diet. These results indicate that the elevated plasma 1,25(OH)2D3 levels observed in rats during dietary phosphate deprivation are due to increased renal synthesis of the hormone.  相似文献   

15.
A liquid chromatographic method is described for the simultaneous determination of cefalexin and trimethoprim in dog plasma. A simple protein precipitation procedure was adopted for the sample preparation with satisfactory extraction recoveries for both analytes. Chromatographic separation of the analytes was achieved on a C(18) column using a mixture of 2 mol/l formate buffer (pH 3.5), methanol and acetonitrile (22:7:7, v/v/v) containing a 0.002 mol/l sodium dodecyl sulfate as mobile phase and detection was performed at 240 nm. The linearity was obtained over the concentration ranges of 1.0-100.0 microg/ml for cefalexin and 0.5-50.0 microg/ml for trimethoprim. For each level of QC samples including the lower limit of quantification, both inter- and intra-day precisions (R.S.D.) were < or =14.0% for cefalexin and < or =11.4% for trimethoprim, and accuracy (RE) was -1.4% for cefalexin and -3.0% for trimethoprim. The present LC method was successfully applied to the pharmacokinetic studies of coformulated cefalexin dispersible tablets after oral administration to beagle dogs.  相似文献   

16.
A simple, sensitive, selective, and reproducible reversed-phase high-performance liquid chromatographic (HPLC) method with UV detection was developed for the determination of lorazepam (LZP) in human plasma, using oxazepam (OZP) as internal standard. LZP and OZP were extracted from alkalinized (pH 9.5) spiked and clinical plasma samples using a single step liquid-liquid extraction with a mixture of n-hexane-dichloromethane (70:30%; v/v). Chromatographic separation was performed on a reversed-phase Synergi Max RP analytical column (150 mmx4.6 mm i.d.; 4 microm particle size), using an aqueous mobile phase (10 mM KH2PO4 buffer (pH 2.4)-acetonitrile; 65:35%, v/v) delivered at a flow-rate of 2.5 ml/min. Retention times for OZP and LZP were 10.2 and 11.9 min, respectively. Calibration curves were linear from 10 to 300 ng with correlation coefficients (r2) better than 0.99. The limits of detection (LOD) and quantification (LOQ) were 2.5 and 10 ng/ml, respectively, using 0.5 ml samples. The mean relative recoveries at 20 and 300 ng/ml were 84.1+/-5.5% (n=6) and 72.4+/-5.9% (n=7), respectively; for OZP at 200 ng the value was 68.2+/-6.8% (n=14). The intra-assay relative standard deviations (R.S.D.) at 20, 150 and 270 ng/ml of LZP were 7.8%, 9.8% (n=7 in all cases) and 6.6% (n=8), respectively. The inter-assay R.S.D. at the above concentrations were 15.9%, 7.7% and 8.4% (n=7 in all cases), respectively. Intra- and inter-assay accuracy data were within the acceptance interval of +/-20% of the nominal values. There was no interference from other commonly co-administered anticonvulsant, antimicrobial, antipyretic, and antimalarial drugs. The method has been successfully applied to a pharmacokinetic study of LZP in children with severe malaria and convulsions following administration of a single intravenous dose (0.1 mg/kg body weight) of LZP.  相似文献   

17.
A simple, rapid and sensitive high-performance liquid chromatographic method was developed for determination of ibuprofen, (+/-)-(R, S)-2-(4-isobutylphenyl)-propionic acid, enantiomers in rat serum. Serum (0.1 ml) was extracted with 2,2,4-trimethylpentane/isopropanol (95:5, v/v) after addition of the internal standard, (S)-naproxen, and acidification with H(2)SO(4). Enantiomeric resolution of ibuprofen was achieved on ChiralPak AD-RH column with ultraviolet (UV) detection at 220 nm without interference from endogenous co-extracted solutes. The calibration curve demonstrated excellent linearity between 0.1 and 50 microg/ml for each enantiomer. The mean extraction efficiency was >92%. Precision of the assay was within 11% (relative standard deviation (R.S.D.)) and bias of the assay was lower than 15% at the limit of quantitation (0.1 microg/ml). The assay was applied successfully to an oral pharmacokinetic study of ibuprofen in rats.  相似文献   

18.
In this work, molecularly imprinted microspheres (MIMs) were synthesized by aqueous microsuspension polymerization using astaxanthin (3,3'-dihydroxy-beta,beta'-carotene-4,4'-dione) as imprinting molecule. The MIMs obtained were subsequently packed into the stainless steel column and the chromatographic characterization of the column was investigated. The effects of pH and composition of the mobile phase on the retention factor (k') were investigated in detail. The mixture of methanol and dichloromethane (DCM) (8:2, v/v) was used as mobile phase A while the mixture of methanol and water (5:5, v/v) as mobile phase B. The separation of astaxanthin and zeaxanthin (3,3'-dihydroxyl-beta-carotene) was obtained when the concentration of mobile phase B was higher than 30% (v/v) due to their strong lipophilicity. The method developed was successfully applied to separate astaxanthin in the saponified samples of the microalga Haematococcus pluvialis and the yeast Phaffia rhodozyma. The recovery of adding 40 mg astaxanthin to 1.0 g microalgal sample was 95.5% with an R.S.D. (n =5) of 5.3%. The results of determination of astaxanthin in the microalga and the yeast were 3.7% (R.S.D (n = 1.5%, n = 9) and 0.041% (R.S.D n= 7.3%, n = 9), respectively.  相似文献   

19.
A method based on solid-phase extraction (SPE) and capillary zone electrophoresis (CZE) for the analysis of tobramycin in human serum is presented. An off-line SPE employing a carboxypropyl bonded phase (CBA) cartridge was used for the extraction of tobramycin from human serum. Adsorbed tobramycin was eluted from the CBA cartridge using a mixture of NH(3) (25%, w/v)-methanol (30:70, v/v). After evaporation, the analyte was reconstituted and derivatized with o-phthaldialdehyde (OPA)/3-mercaptopropionic acid (MPA). The resulting tobramycin-OPA/MPA derivative was purified, and then identified by mass spectrometry. The tobramycin-OPA/MPA derivative was then analysed by CZE with a background electrolyte (BGE) comprising of 30 mM sodium tetraborate pH 10.0-acetonitrile (ACN) (80:20, v/v) with ultraviolet detection at 230 nm. A linear response was observed in the range of 0.3-30 microg/ml with r(2) = 0.992. The sensitivity of the method was determined by its limit of quantitation (LOQ) and limit of detection (LOD) of 0.3 microg/ml and 0.1 microg/ml, respectively. SPE recovery ranged from 68 to 79% at the trough levels to 98% at the peak levels found in serum. Furosemide has been added as internal standard (IS) to improve precision. For the therapeutic range of tobramycin in serum (2-10 microg/ml) the relative standard deviation (R.S.D.) was less than 11% for the entire SPE/CE process. The method demonstrated excellent selectivity as shown by the lack of interference from a total of 20 drugs investigated. The method was then used in therapeutic drug monitoring of patients receiving the drug.  相似文献   

20.
Mitoguazone is an antiproliferative agent used in chemotherapy. This study describes a simple and sensitive high-performance liquid chromatographic method for the determination of mitoguazone in 100 microl of plasma. Samples were deproteinized with 100 microl of a solution of internal standard (amiloride, 10 microg/ml) in acetonitrile. An aliquot of the supernatant was injected onto the column. HPLC separation was achieved on a silica column with the mobile phase of methanol-50 mM potassium phosphate buffer (pH 3)-triethylamine (80:20:0.3, v/v), at a flow-rate of 1 ml/min. The eluent was detected at 320 nm. The retention time was about 5.5 min for amiloride and 12 min for mitoguazone. No endogenous substances were found to interfere. Calibration curves were linear from 0.25 to 50 microg/ml. The absolute recoveries of mitoguazone and amiloride were both greater than 84%. The limit of quantitation was 0.25 microg/ml. The intra- and inter-day precision (expressed as RSD) was 5.8%, or less, and the accuracy was 94.7% of the nominal concentration. The method is suitable in pharmacokinetic investigation and monitoring mitoguazone concentration.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号