共查询到20条相似文献,搜索用时 15 毫秒
1.
Stable films of didodecyldimethylammonium bromide (DDAB, a synthetic lipid) and horseradish peroxidase (HRP) were made by casting the mixture of the aqueous vesicle of DDAB and HRP onto the glassy carbon (GC) electrode. The direct electron transfer between electrode and HRP immobilized in lipid film has been demonstrated. The lipid films were used to supply a biological environment resembling biomembrane on the surface of the electrode. A pair of redox peaks attributed to the direct redox reaction of HRP were observed in the phosphate buffer solution (pH 5.5). The cathodic peak current increased dramatically while anodic peak decreased by addition of small amount H(2)O(2). The pH effect on amperometric response to H(2)O(2) was studied. The biosensor also exhibited fast response (5 s), good stability and reproducibility. 相似文献
2.
The result of cyclic voltammetry shows that polyaniline doped with ferrocenesulfonic acid (PAnFc) can effectively catalyze the oxidation of hydrogen peroxide, so PAnFc is used as a sensor to determine the concentration of H2O2. Iron in the ferrocenesulfonic acid exists in two oxidation states: Fe2+ and Fe3+. They can reversibly oxidize and reduce between the Fe2+ and Fe3+ oxidation states, which play an important role in the catalytic oxidation of H2O2. The response current of the sensor depends on the pH, applied potential and temperature at a given concentration of H2O2. At optimum conditions, the sensor has a fast response to H2O2, good operational stability, a good linear response to H2O2 in the range from 4 to 64 microM, and a small temperature dependence of the response current. 相似文献
3.
A new enzyme electrode for the determination of alcohols was developed by immobilizing alcohol oxidase in polvinylferrocenium matrix coated on a Pt electrode surface. The amperometric response due to the electrooxidation of enzymatically generated H(2)O(2) was measured at a constant potential of +0.70 V versus SCE. The effects of substrate, buffer and enzyme concentrations, pH and temperature on the response of the electrode were investigated. The optimum pH was found to be pH 8.0 at 30 degrees C. The steady-state current of this enzyme electrode was reproducible within +/-5.0% of the relative error. The sensitivity of the enzyme electrode decreased in the following order: methanol>ethanol>n-butanol>benzyl alcohol. The linear response was observed up to 3.7 mM for methanol, 3.0 mM for ethanol, 6.2 mM for n-butanol, and 5.2 mM for benzyl alcohol. The apparent Michaelis-Menten constant (K(Mapp)) value and the activation energy, E(a), of this immobilized enzyme system were found to be 5.78 mM and 38.07 kJ/mol for methanol, respectively. 相似文献
4.
Reduction of hydrogen peroxide and organic peroxides (t-butyl hydroperoxide and linoleic acid hydroperoxide) was achieved with homovanillic acid as hydrogen donor in the presence of the triethylenetetramine-Fe3+ complex. By the catalytic action of this complex, homovanillic acid is oxidized to its fluorescent dimer. Based on this reaction a fluorometric method for the measurement of the hydroperoxides mentioned above is described. The method can be extended to the determination of substrate-enzyme systems that produce hydrogen peroxide, e.g., glucose-glucose oxidase. The method allows the determination of substances such as hydrogen peroxide and t-butyl hydroperoxide with an accuracy and precision of less than 3%. Glucose can be determined with similar precision and an accuracy of 4.7%. 相似文献
5.
A biosensor for detection of formate at submicromolar concentrations has been developed by co-immobilizing formate dehydrogenase (FDH, E.C. 1.2.1.2), salicylate hydroxylase (SHL, E.C. 1.14.13.1) and NAD(+) linked to polyethylene glycol (PEG-NAD(+)) in a poly(vinyl alcohol) (PVA) matrix in front of a Clark-electrode. The principle of the bi-enzyme scheme is as follows: formate dehydrogenase converts formate into carbon dioxide using PEG-NAD(+). Corresponding PEG-NADH produced is then oxidized to PEG-NAD(+) by salicylate hydroxylase using sodium salicylate and oxygen. The oxygen consumption is monitored with the Clark-electrode. The advantages of this biosensor approach are the effective re-oxidation of PEG-NADH, and the entrapment of PEG-NAD(+) resulting in avoiding the addition of expensive cofactor to the working medium for each measurement. This bi-enzyme sensor has achieved a linear range of 1-300 microM and a detection limit of 1.98 x 10(-7) M for formate (S/N=3), with the response time of 4 min. The working stability is limited to 7 days due to the inactivation of the enzymes. Only sodium salicylate was needed in milli-molar amounts. 相似文献
6.
A simple colorimetric method for determination of hydrogen peroxide in plant tissues 总被引:7,自引:0,他引:7
Biyan Zhou Jihua Wang Zhenfei Guo Huoquan Tan Xiaochuan Zhu 《Plant Growth Regulation》2006,49(2-3):113-118
A simple colorimetric method for determination of hydrogen peroxide in plant materials is described. The method is based on hydrogen peroxide producing a stable red product in reaction with 4-aminoantipyrine and phenol in the presence of peroxidase. Plant tissues was ground with trichloroacetic acid (5% w/v) and extracts were adjusted to pH 8.4 with ammonia solution. Activated charcoal was added to the homogenate to remove pigments, antioxidants and other interfering substances. The colorimetric reagent (pH 5.6) consisted of 4-aminoantipyrine, phenol, and peroxidase. With this method, we have determined the hydrogen peroxide concentration in leaves of eight species which ranged from 0.2 to 0.8 μmol g−1 FW. Changes in hydrogen peroxide concentration of Stylosanthes guianensis in response to heat stress are also analyzed using this method. 相似文献
7.
Dimcheva N Horozova E Jordanova Z 《Zeitschrift für Naturforschung. C, Journal of biosciences》2002,57(9-10):883-889
A xanthine oxidase enzyme electrode (xanthine oxidase immobilized on electrochemically modified graphite and conveniently coated with gelatine electrode working surface) for quantitative analysis of xanthine is proposed. The detection of thus developed electrochemical system is based on the electroreduction of hydrogen peroxide generated in enzyme layer and offered L-ascorbic and uric acid reducing interference effect on the substrate determination. At a working potential -50 mV (vs. Ag/AgCl) the detection limit of 4.5 microM and the linearity of the amperometric signal up to substrate concentration of about 40 microM were found. At that working potential, the electrode is practically inert towards L-ascorbic- and uric acid present. The response time did not exceed 2 min. 相似文献
8.
A novel hydrogen peroxide biosensor was fabricated by using a DNA-Cu(II) complex as a novel electrocatalyst for the reduction of hydrogen peroxide (H2O2). A polyion complex (PIC) membrane composed of DNA and poly(allylamine) (PAA) functioned as a support matrix for immobilization of electrocatalytic element-copper ion. The circular dichroism (CD) spectrum of the DNA-Cu(II)/PAA membrane in wet state showed that the DNA exists in B-like form within the membrane. Electrochemical measurements of the DNA-Cu(II)/PAA membrane-modified glassy carbon (GC) electrode revealed that the copper ion embedded in the DNA/PAA layer exhibits good electrochemical behaviors, and the electrochemical rate constant between the immobilized copper ion and the GC electrode surface was estimated to be 26.4 s(-1). The resulting DNA-Cu(II)/PAA/GC electrode showed an excellent electrocatalytic activity for the H2O2 reduction. The sensitivity of the sensor for the determination of H2O2 was affected by the amount of each component, such as copper ion, DNA and PAA in the DNA-Cu(II)/PAA membrane. Effects of applied potential, pH, temperature, ionic strength and buffer concentrations upon the response currents of the sensor were also investigated for an optimum analytical performance. Even in the presence of dissolved oxygen, the sensor exhibited highly sensitive and rapid (response time, less than 5 s) response to H2O2. The steady-state cathodic current responses of the sensor obtained at -0.2 V versus Ag/AgCl in air-saturated 50 mM phosphate buffer (pH 5.0) increased linearly up to 135 microM with the detection limit of 50 nM. Interference by ascorbic acid and uric acid due to the reduction of Cu(II) was effectively cancelled by further modification of outermost layer of polyion complex film. In addition, the sensor exhibited good reproducibility and stability. 相似文献
9.
A series of hybrid iron-cobalt hexacyanoferrate (FeCoHCF) films were electrodeposited on gold electrodes from solutions containing 6mM Fe(CN)(6)(3-) with different concentrations of Co(2+) and Fe(3+). FeCoHCF films deposited from solutions with different molar ratios of iron were studied by cyclic voltammetry, and their solid states were characterized by Fourier transform infrared spectroscopy. The kind of FeCoHCF film that deposited from a solution with a molar ratio of iron of 0.4 showed the largest response current to H(2)O(2) and was characterized by energy-dispersive X-ray spectroscopy. Therefore, the optimized FeCoHCF film was combined with nonconducting poly(o-aminophenol) (POAP) film that entrapped the hemoglobin (Hb) to construct hydrogen peroxide biosensor. The response current of the Hb/POAP/FeCoHCF/Au electrode (29.8 nA) was nearly 40 and was 1.5 times that of the Hb/POAP/Au (0.7 nA) and POAP/FeCoHCF/Au (20 nA) electrodes, respectively. The Michaelis-Menten constant of Hb in the Hb/POAP/FeCoHCF/Au film was 9.31 mM. These results show that the immobilized Hb in the Hb/POAP/FeCoHCF/Au film exhibits higher catalytic activity and larger response current to H(2)O(2) by the mediation of FeCoHCF. In addition, effects of applied potential, solution pH, and electroactive interferent on the response current of the Hb/POAP/FeCoHCF/Au electrode were investigated in detail. 相似文献
10.
Eriberta Nepomuceno Navera Koji Sode Eiichi Tamiya Isao Karube 《Biosensors & bioelectronics》1991,6(8):675-680
An enzyme sensor is developed using carbon fiber to measure acetylcholine concentration. The mechanism is based on the detection of H2O2 which is a product of the sequential enzyme reactions of acetylcholinesterase and choline oxidase. The fabrication of the electrode is described. The sensor is polarized at 1.2 V. Enzymes are co-immobilized in polyvinyl alcohol containing styryl pyrydinium (photo-crosslinkable polymer). A fast response time of 0.8 min is obtained. A linear correlation is observed between 0.2 and 1.0 mM. Other optimal operational conditions with respect to pH, temperature and stability are discussed. The use of carbon fiber containing co-immobilized enzymes could offer several model advantages especially in neuroscience research. In conclusion, the aims of the present work are centered on carbon fiber electrode fabrication, immobilization electrochemical measurements. 相似文献
11.
Jun Wan 《Analytical biochemistry》2009,386(2):256-59
A novel nanocomposite material of multiwalled carbon nanotubes (MWCNTs) and room temperature ionic liquid (RTIL) N-butylpyridinium hexafluorophosphate (BPPF6) was explored and used to construct a novel microperoxidase-11 (MP-11) biosensor for the determination of hydrogen peroxide (H2O2). Cyclic voltammetry (CV) and differential pulse voltammetry (DPV) were used to characterize the performance of the biosensor. Under the optimized experimental conditions, H2O2 could be detected in a linear calibration range of 0.5 to 7.0 × 10−7 mol L−1 with a correlation coefficient of 0.9949 (n = 9) and a detection limit of 3.8 × 10−9 mol L−1 at 3σ. The modified electrodes displayed excellent electrochemical response, high sensitivity, long-term stability, and good bioactivity and selectivity. 相似文献
12.
A novel electrochemical sensor surface with enhanced sensitivity for the detection of hydrogen peroxide has been developed based on the layer-by-layer assembly of mercapto propionic acid (MPA), cystine-based polymethylene-bridged cyclic bisureas (CBU)/gold nanoparticle (AuNP) and horseradish peroxidase (HRP) on gold electrode. Possibility of a large number of hydrogen bonds, allowed by the chemical and sterical structure of the CBU ensures the proper immobilization of the enzyme in favorable orientation and retention of enzymatic activity. Efficient electron tunneling property of AuNP together with its electrocatalytic activity leads to higher sensitivity in the detection of H(2)O(2). In cyclic voltammetry measurements a cathodic current due to direct electron transfer of HRP is observed which, indicates excellent electrocatalytic activity of the sensor surface. The biosensor surface modified with gold nanoparticle and CBU showed a lower detection limit of 50 nM for hydrogen peroxide. Chronoamperometry is performed at -0.3 V and Michaelis-Menten constant K(M)(app) value is estimated to be 4.5 μM. The newly developed sensor surface showed very high stability, reproducibility and high sensitivity. 相似文献
13.
A microbiosensor for hydrogen peroxide (H2O2) was constructed by immobilizing catalase in a polyacrylamide gel on the tip of a Clark-type oxygen microelectrode. The outer tip diameter was 15–40 m. The sensors had response times of 0.7–1.2 s, and could detect as little as 2–4 M H2O2. They could measure with a spatial resolution of about 100m and remained operational for up to three weeks. 相似文献
14.
A convenient and effective way for fabricating amperometric hydrogen peroxide (H2O2) biosensor was designed in this paper. First, the polyaniline (PANI) nanofibers membrane with good conductance and high surface
area was electropolymerized on a gold electrode surface. Then, Pt nanoparticle (PtNP) was electrochemically deposited on the
PANI nanofibers membrane. Finally, the hybrid film of gold nanoparticle, chitosan, and horseradish peroxidase (HRP) was cast
onto the modified electrode to form a stable biofunctional film, which was also employed as a protective layer to PtNP. The
proposed biosensor exhibited a rapid response to H2O2 with the linear range from 7.0 × 10−6 to 1.4 × 10−2 M and a detection limit of 2.8 × 10−6 M (S/N = 3). The sensitivity of 558 μA mM−1 cm−2 was obtained. The Michaelis–Menten constant,
K\textM\textapp K_{\text{M}}^{\text{app}} value was 1.90 mM suggesting a high affinity. Moreover, it displayed a good reproducibility and long-term stability. 相似文献
15.
A mediator-free amperometric hydrogen peroxide biosensor was prepared by immobilizing horseradish peroxidase (HRP) enzyme
on colloidal Au modified platinum (Pt) wire electrode, which was modified by poly 2,6-pyridinediamine (pPA). The modified
process was characterized by electrochemical impedance spectroscopy (EIS), and the electrochemical characteristics of the
biosensor were studied by cyclic voltammetry, linear sweep voltammetry and chronoamperometry. The biosensor displayed an excellent
electrocatalytical response to reduction of H2O2 without the aid of an electron mediator, the linear range was 4.2 × 10−7–1.5 × 10−3 mol/L (r = 0.9977), with a detection limit of 1.4 × 10−7 mol/L. Moreover, the performance and factors influencing the resulted biosensor were studied in detail. The studied biosensor
exhibited permselectivity, good stability and good fabrication reproducibility. 相似文献
16.
《Journal of Molecular Catalysis .B, Enzymatic》2011,73(3-4):276-281
A nylon membrane based amperometric biosensor employing banana fruit polyphenol oxidase (PPO) is presented for polyphenol detection. Nylon membrane was first activated and then coupled with chitosan. PPO was covalently attached to this membrane through glutaraldehyde coupling. The membrane bioconjugate was characterized by scanning electron microscopy (SEM) and Fourier Transform Infrared (FTIR) study and then mounted onto Au electrode using parafilm to construct a working electrode. Once assembled along with Ag/AgCl as reference and Pt as auxiliary electrode, the biosensor gave optimum response within 15 s at pH 7.5 and 30 °C, when polarized at +0.4 V. The response (in mA) was directly proportional to polyphenol concentration in the range 0.2–400 μM. The lower detection limit of the biosensor was 0.2 μM. The biosensor was employed for determination of polyphenols in tea, beverages and water samples. The enzyme electrode showed 25% decrease in initial activity after 150 reuses over 6 months, when stored at 4 °C. 相似文献
17.
Nitric oxide (NO) is generated in biological systems and plays an important role as a bioregulatory molecule. Its ability to bind hemoglobin and myoglobin is well known. Moreover, it may lose an electron forming the nitrosyl group involved in the formation of S-nitrosothiols. The main problem in analyzing NO is its extreme reactivity. We have tackled this task by using an amperometric sensor to determine free NO, S-nitrosothiols (such as S-nitrosoglutathione), and nitrite in cell-free systems and murine microglial cell cultures. The determination of nitrosothiols is of biochemical relevance and a difficult task particularly at low concentration values. In this article we describe a new method based on the reductive cleavage of the S-NO bond by cuprous ions followed by a solid-state amperometric determination. The system described by us is sensitive, rapid, does not require previous purification steps, is easy to perform, and is inexpensive. For this reason, we think that it may represent an important analytical improvement. It has been suggested that nitrosothiols may exert biological activity by acting as a reservoir of NO. We tested the production of nitrite and of RSNO in stimulated, cultured murine microglial cells and we have shown that nitrite accumulates in these conditions. GSNO also accumulates, provided that GSH is present in the medium. 相似文献
18.
S Alexandre J Telegdi I Boutelet S Julien J C Vincent 《Comptes rendus de l'Académie des sciences. Série III, Sciences de la vie》1992,315(3):85-91
A new spectrophotometric method for determining low hydrogen peroxide concentrations by using horseradish peroxidase in the presence of NADH at pH 7.5 has been described. Both total NADH consumption and initial reaction rate may be used for the determination. Using the NADH consumption, a linear response with respect to hydrogen peroxide was observed in the concentration range 7 x 10(-8)-2.5 x 10(-6) M. Due to the presence of superoxide dismutase, hydrogen peroxide is partly regenerated and an amplification of the signal results, which explains the sensitivity. 相似文献
19.
20.
《Biochimica et Biophysica Acta (BBA)/General Subjects》2016,1860(2):452-464
BackgroundCerium oxide (CeO2) and Ce-doped nanostructured materials (NMs) are being seen as innovative therapeutic tools due to their exceptional antioxidant effects; nevertheless their bio-applications are still in their infancy.MethodsTiO2, Ce–TiO2 and CeO2–TiO2 NMs were synthesized by a bottom-up microemulsion-mediated strategy and calcined during 7 h at 650 °C under air flux. The samples were compared to elucidate the physicochemical characteristics that determine cellular uptake, toxicity and the influence of redox balance between the Ce3 +/Ce4 + on the cytoprotective role against an exogenous ROS source: H2O2. Fibroblasts were selected as a cell model because of their participation in wound healing and fibrotic diseases.ResultsCe–TiO2 NM obtained via sol–gel reaction chemistry of metallic organic precursors exerts a real cytoprotective effect against H2O2 over fibroblast proliferation, while CeO2 pre-formed nanoparticles incorporated to TiO2 crystalline matrix lead to a harmful CeO2–TiO2 material. TiO2 was processed by the same pathways as Ce–TiO2 and CeO2–TiO2 NM but did not elicit any adverse or protective influence compared to controls.ConclusionsIt was found that the Ce atoms source and its concentration have a clear effect on material's physicochemical properties and its subsequent influence in the cellular response. It can induce a range of biological reactions that vary from cytotoxic to cytoprotective.General significanceEven though there are still some unresolved issues and challenges, the unique physical and chemical properties of Ce-based NMs are fascinating and versatile resources for different biomedical applications. 相似文献