首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 125 毫秒
1.
Current microarray technology allows researchers to genotype a large number of SNPs with relatively small amounts of DNA. Nevertheless, researchers and clinicians still frequently face the problem of acquiring enough high-quality DNA for analysis. Whole-genome amplification (WGA) methods offer a solution for this problem, and earlier studies have shown that WGA samples perform reasonably well in small-scale genetic analyses (e.g. Affymetrix 10K array). To determine the performance of WGA products on a large-scale genotyping array, we compared the Affymetrix 250K array genotyping results of genomic DNA and their WGA products from four individuals. Our results indicate that WGA product performs well on the 250K array compared to genomic DNA, especially when using the BRLMM calling algorithm. WGA samples have high call rates (97.5% on average, compared to 99.4% for genomic DNA) and excellent concordance rates with their corresponding genomic DNA samples (98.7% on average). In addition, no apparent systematic genomic amplification bias can be detected. This study demonstrates that, although there is a slight decrease in the total call rates, WGA methods provide a reliable approach for increasing the amount of DNA samples for use with a common SNP genotyping array.  相似文献   

2.

Background

Whole genome amplification (WGA) promises to eliminate practical molecular genetic analysis limitations associated with genomic DNA (gDNA) quantity. We evaluated the performance of multiple displacement amplification (MDA) WGA using gDNA extracted from lymphoblastoid cell lines (N = 27) with a range of starting gDNA input of 1–200 ng into the WGA reaction. Yield and composition analysis of whole genome amplified DNA (wgaDNA) was performed using three DNA quantification methods (OD, PicoGreen® and RT-PCR). Two panels of N = 15 STR (using the AmpFlSTR® Identifiler® panel) and N = 49 SNP (TaqMan®) genotyping assays were performed on each gDNA and wgaDNA sample in duplicate. gDNA and wgaDNA masses of 1, 4 and 20 ng were used in the SNP assays to evaluate the effects of DNA mass on SNP genotyping assay performance. A total of N = 6,880 STR and N = 56,448 SNP genotype attempts provided adequate power to detect differences in STR and SNP genotyping performance between gDNA and wgaDNA, and among wgaDNA produced from a range of gDNA templates inputs.

Results

The proportion of double-stranded wgaDNA and human-specific PCR amplifiable wgaDNA increased with increased gDNA input into the WGA reaction. Increased amounts of gDNA input into the WGA reaction improved wgaDNA genotyping performance. Genotype completion or genotype concordance rates of wgaDNA produced from all gDNA input levels were observed to be reduced compared to gDNA, although the reduction was not always statistically significant. Reduced wgaDNA genotyping performance was primarily due to the increased variance of allelic amplification, resulting in loss of heterozygosity or increased undetermined genotypes. MDA WGA produces wgaDNA from no template control samples; such samples exhibited substantial false-positive genotyping rates.

Conclusion

The amount of gDNA input into the MDA WGA reaction is a critical determinant of genotyping performance of wgaDNA. At least 10 ng of lymphoblastoid gDNA input into MDA WGA is required to obtain wgaDNA TaqMan® SNP assay genotyping performance equivalent to that of gDNA. Over 100 ng of lymphoblastoid gDNA input into MDA WGA is required to obtain optimal STR genotyping performance using the AmpFlSTR® Identifiler® panel from wgaDNA equivalent to that of gDNA.
  相似文献   

3.
增强PCR和全基因组扩增是当前微量DNA分析的主要策略,但是,由于DNA模板量过少,受随机效应影响显著,往往不能得到可靠的DNA分型结果.本文提出一种新的检验策略:PLP-LDR-HRCA,尝试微量DNA检材的SNPs分型研究.选择rs17750303位点,并设计等位基因特异性锁式探针,采用连接酶检测反应来识别等位基因,而后采用超分支滚环扩增反应来放大检测信号.结果表明,PLP-LDR-HRCA反应特异性好,灵敏度高,能够直接鉴别微量基因组DNA模板中待测SNP位点,rs17750303纯合型样品(AA型或CC型)和杂合型样品(AC型)准确分型所需最少模板量分别为20pg和30pg.对于增强PCR和全基因组扩增技术不能有效检验的微量检材,PLP-LDR-PCR策略独具优势,可能具有较大的开发价值.  相似文献   

4.
We assessed the whole genome amplification strategy, known as multiple displacement amplification (MDA), for use with the TaqMan genotyping platform for DNA samples derived from two case-control studies nested in the Nurses' Health Study and the Physicians' Health Study. Our objectives were to (1) quantify DNA yield from samples of varying starting concentrations and (2) assess whether MDA products give an accurate representation of the original genomic sequence. Multiple displacement amplification yielded a mean 23000-fold increase in DNA quantity and genotyping results demonstrate 99.95% accuracy across six SNPs from four genes for 352 samples included in this study. These results suggest that MDA will provide a sufficiently robust amplification of limiting samples of genomic DNA that can be used for SNP genotyping in large case-control studies of complex diseases.  相似文献   

5.
Multiple displacement amplification (MDA) has emerged as a promising new method of whole genome amplification (WGA) with the potential to generate virtually unlimited genome-equivalent DNA from only a small amount of seed DNA. To date, genome-wide high marker density assessments of MDA–DNA have focussed mainly upon suitability for single nucleotide polymorphism (SNP) genotyping applications. Suitability for short tandem repeat (STR) genotyping has not been investigated in great detail, despite their inherent instability during DNA replication, and the obvious challenge that this presents to WGA techniques. Here, we aimed to assess the applicability of MDA in STR genotyping by conducting a genome-wide scan of 768 STR markers for MDAs of 15 high quality genomic DNAs. We found that MDA genotyping call and accuracy rates were only marginally lower than for genomic DNA. Pooling of three replicate MDAs resulted in a small increase in both call rate and genotyping accuracy. We identified 34 STRs (4.4% of total markers) of which five essentially failed with MDA samples, and 29 of which showed elevated genotyping failures/discrepancies in the MDAs. We emphasise the importance of DNA and MDA quality checks, and the use of appropriate controls to identify problematic STR markers.  相似文献   

6.

Background

Until recently, only a small number of low- and mid-throughput methods have been used for single nucleotide polymorphism (SNP) discovery and genotyping in grapevine (Vitis vinifera L.). However, following completion of the sequence of the highly heterozygous genome of Pinot Noir, it has been possible to identify millions of electronic SNPs (eSNPs) thus providing a valuable source for high-throughput genotyping methods.

Results

Herein we report the first application of the SNPlex? genotyping system in grapevine aiming at the anchoring of an eukaryotic genome. This approach combines robust SNP detection with automated assay readout and data analysis. 813 candidate eSNPs were developed from non-repetitive contigs of the assembled genome of Pinot Noir and tested in 90 progeny of Syrah × Pinot Noir cross. 563 new SNP-based markers were obtained and mapped. The efficiency rate of 69% was enhanced to 80% when multiple displacement amplification (MDA) methods were used for preparation of genomic DNA for the SNPlex assay.

Conclusion

Unlike other SNP genotyping methods used to investigate thousands of SNPs in a few genotypes, or a few SNPs in around a thousand genotypes, the SNPlex genotyping system represents a good compromise to investigate several hundred SNPs in a hundred or more samples simultaneously. Therefore, the use of the SNPlex assay, coupled with whole genome amplification (WGA), is a good solution for future applications in well-equipped laboratories.  相似文献   

7.
Whole-genome amplification (WGA) methods were adopted for single-nucleotide-polymorphism (SNP) typing to minimize the amount of genomic DNA that has to be used in typing for thousands of different SNPs in large-scale studies; 5-10 ng of genomic DNA was amplified by a WGA method (improved primer-extension-preamplification-polymerase chain reaction (I-PEP-PCR), degenerated oligonucleotide primer-PCR (DOP-PCR), or multiple displacement amplification (MDA)). Using 1/100 to 1/500 amounts of the whole-genome-amplified products as templates, subsequent analyses were successfully performed. SNPs were genotyped by the sequence-specific primer (SSP)-PCR method followed by fluorescence correlation spectroscopy (FCS). The typing results were evaluated for four different SNPs on tumor necrosis factor receptor 1 and 2 genes (TNFR1 and TNFR2). The genotypes determined by the SSP-FCS method using the WGA products were 100% in concordance with those determined by nucleotide sequencing using genomic DNAs. We have already carried out typing of more than 300 different SNPs and are currently performing 7,500-10,000 typings per day using WGA samples from patients with several common diseases. WGA coupled with FCS allows specific and high-throughput genotyping of thousands of samples for thousands of different SNPs.  相似文献   

8.
DNA quantity can be a hindrance in ecological and evolutionary research programmes due to a range of factors including endangered status of target organisms, available tissue type, and the impact of field conditions on preservation methods. A potential solution to low‐quantity DNA lies in whole genome amplification (WGA) techniques that can substantially increase DNA yield. To date, few studies have rigorously examined sequence bias that might result from WGA and next‐generation sequencing of nonmodel taxa. To address this knowledge deficit, we use multiple displacement amplification (MDA) and double‐digest RAD sequencing on the grey mouse lemur (Microcebus murinus) to quantify bias in genome coverage and SNP calls when compared to raw genomic DNA (gDNA). We focus our efforts in providing baseline estimates of potential bias by following manufacturer's recommendations for starting DNA quantities (>100 ng). Our results are strongly suggestive that MDA enrichment does not introduce systematic bias to genome characterization. SNP calling between samples when genotyping both de‐novo and with a reference genome are highly congruent (>98%) when specifying a minimum threshold of 20X stack depth to call genotypes. Relative genome coverage is also similar between MDA and gDNA, and allelic dropout is not observed. SNP concordance varies based on coverage threshold, with 95% concordance reached at ~12X coverage genotyping de‐novo and ~7X coverage genotyping with the reference genome. These results suggest that MDA may be a suitable solution for next‐generation molecular ecological studies when DNA quantity would otherwise be a limiting factor.  相似文献   

9.
When cytobrush buccal cell samples have been collected as a genomic DNA (gDNA) source for an epidemiological study, whole genome amplification (WGA) can be critical to maintain sufficient DNA for genotyping. We evaluated REPLI-g WGA using gDNA from two paired cytobrushes (cytobush 'A' kept in a cell lysis buffer, and 'B' dried and kept at room temperature for 3 days, and frozen until DNA extraction) in a pilot study (n=21), and from 144 samples collected by mail in a breast cancer study. WGA success was assessed as the per cent completion/concordance of STR/SNP genotypes. Locus amplification bias was assessed using quantitative PCR of 23 human loci. The pilot study showed > 98% completion but low genotype concordance between cytobrush wgaDNA and paired blood gDNA (82% and 84% for cytobrushes A and B, respectively). Substantial amplification bias was observed with significantly lower human gDNA amplification from cytobrush B than A. Using cytobrush gDNA samples from the breast cancer study (n =20), an independent laboratory demonstrated that increasing template gDNA to the REPLI-g reaction improved genotype performance for 49 SNPs; however, average completion and concordance remained below 90%. To reduce genotype misclassification when cytobrush wgaDNA is used, inclusion of paired gDNA/wgaDNA and/or duplicate wgaDNA samples is critical to monitor data quality.  相似文献   

10.

Background

Rolling circle amplification of ligated probes is a simple and sensitive means for genotyping directly from genomic DNA. SNPs and mutations are interrogated with open circle probes (OCP) that can be circularized by DNA ligase when the probe matches the genotype. An amplified detection signal is generated by exponential rolling circle amplification (ERCA) of the circularized probe. The low cost and scalability of ligation/ERCA genotyping makes it ideally suited for automated, high throughput methods.

Results

A retrospective study using human genomic DNA samples of known genotype was performed for four different clinically relevant mutations: Factor V Leiden, Factor II prothrombin, and two hemochromatosis mutations, C282Y and H63D. Greater than 99% accuracy was obtained genotyping genomic DNA samples from hundreds of different individuals. The combined process of ligation/ERCA was performed in a single tube and produced fluorescent signal directly from genomic DNA in less than an hour. In each assay, the probes for both normal and mutant alleles were combined in a single reaction. Multiple ERCA primers combined with a quenched-peptide nucleic acid (Q-PNA) fluorescent detection system greatly accellerated the appearance of signal. Probes designed with hairpin structures reduced misamplification. Genotyping accuracy was identical from either purified genomic DNA or genomic DNA generated using whole genome amplification (WGA). Fluorescent signal output was measured in real time and as an end point.

Conclusions

Combining the optimal elements for ligation/ERCA genotyping has resulted in a highly accurate single tube assay for genotyping directly from genomic DNA samples. Accuracy exceeded 99 % for four probe sets targeting clinically relevant mutations. No genotypes were called incorrectly using either genomic DNA or whole genome amplified sample.  相似文献   

11.

Background

Single nucleotide polymorphisms (SNPs) are the foundation of powerful complex trait and pharmacogenomic analyses. The availability of large SNP databases, however, has emphasized a need for inexpensive SNP genotyping methods of commensurate simpliCity, robustness, and scalability. We describe a solution-based, microtiter plate method for SNP genotyping of human genomic DNA. The method is based upon allele discrimination by ligation of open circle probes followed by rolling circle amplification of the signal using fluorescent primers. Only the probe with a 3' base complementary to the SNP is circularized by ligation.

Results

SNP scoring by ligation was optimized to a 100,000 fold discrimination against probe mismatched to the SNP. The assay was used to genotype 10 SNPs from a set of 192 genomic DNA samples in a high-throughput format. Assay directly from genomic DNA eliminates the need to preamplify the target as done for many other genotyping methods. The sensitivity of the assay was demonstrated by genotyping from 1 ng of genomic DNA. We demonstrate that the assay can detect a single molecule of the circularized probe.

Conclusions

Compatibility with homogeneous formats and the ability to assay small amounts of genomic DNA meets the exacting requirements of automated, high-throughput SNP scoring.  相似文献   

12.
Abstract

When cytobrush buccal cell samples have been collected as a genomic DNA (gDNA) source for an epidemiological study, whole genome amplification (WGA) can be critical to maintain sufficient DNA for genotyping. We evaluated REPLI-g? WGA using gDNA from two paired cytobrushes (cytobush ‘A’ kept in a cell lysis buffer, and ‘B’ dried and kept at room temperature for 3 days, and frozen until DNA extraction) in a pilot study (n=21), and from 144 samples collected by mail in a breast cancer study. WGA success was assessed as the per cent completion/concordance of STR/SNP genotypes. Locus amplification bias was assessed using quantitative PCR of 23 human loci. The pilot study showed > 98% completion but low genotype concordance between cytobrush wgaDNA and paired blood gDNA (82% and 84% for cytobrushes A and B, respectively). Substantial amplification bias was observed with significantly lower human gDNA amplification from cytobrush B than A. Using cytobrush gDNA samples from the breast cancer study (n =20), an independent laboratory demonstrated that increasing template gDNA to the REPLI-g reaction improved genotype performance for 49 SNPs; however, average completion and concordance remained below 90%. To reduce genotype misclassification when cytobrush wgaDNA is used, inclusion of paired gDNA/wgaDNA and/or duplicate wgaDNA samples is critical to monitor data quality.  相似文献   

13.
The ability to genotype multiple loci of single cells would be of significant benefit to investigations of cellular processes such as oncogenesis, meiosis, fertilization, and embryogenesis. We report a simple two-step, single-tube protocol for whole-genome amplification (WGA) from single human cells using components of the GenomiPhi V2 DNA Amplification kit. For the first time, we demonstrate reliable generation of 4-7 microg amplified DNA from a single human cell within 4 h with a minimum amount of artifactual DNA synthesis. DNA amplified from single cells was genotyped for 13 heterozygous short tandem repeats (STRs) and 7 heterozygous single nucleotide polymorphisms (SNPs), and the genotyping results were compared with purified genomic DNA. Accuracy of genotyping (percent of single-cell amplifications genotyped accurately for any particular STR or SNP) varied from 37% to 100% (with an average of 80%) for STRs and from 89% to 100% (averaging 94%) for SNPs. We suggest that the method described in this report is suitable for WGA from single cells, the product of which can be subsequently used for many applications, such as preimplantation genetic analysis (PGD).  相似文献   

14.
We have developed a locus-specific DNA target preparation method for highly multiplexed single nucleotide polymorphism (SNP) genotyping called MARA (Multiplexed Anchored Runoff Amplification). The approach uses a single primer per SNP in conjunction with restriction enzyme digested, adapter-ligated human genomic DNA. Each primer is composed of common sequence at the 5′ end followed by locus-specific sequence at the 3′ end. Following a primary reaction in which locus-specific products are generated, a secondary universal amplification is carried out using a generic primer pair corresponding to the oligonucleotide and genomic DNA adapter sequences. Allele discrimination is achieved by hybridization to high-density DNA oligonucleotide arrays. Initial multiplex reactions containing either 250 primers or 750 primers across nine DNA samples demonstrated an average sample call rate of ~95% for 250- and 750-plex MARA. We have also evaluated >1000- and 4000-primer plex MARA to genotype SNPs from human chromosome 21. We have identified a subset of SNPs corresponding to a primer conversion rate of ~75%, which show an average call rate over 95% and concordance >99% across seven DNA samples. Thus, MARA may potentially improve the throughput of SNP genotyping when coupled with allele discrimination on high-density arrays by allowing levels of multiplexing during target generation that far exceed the capacity of traditional multiplex PCR.  相似文献   

15.
Major efforts are underway to systematically define the somatic and germline genetic variations causally associated with disease. Genome-wide genetic analysis of actual clinical samples is, however, limited by the paucity of genomic DNA available. Here we have tested the fidelity and genome representation of phi29 polymerase-based genome amplification (phi29MDA) using direct sequencing and high density oligonucleotide arrays probing >10,000 SNP alleles. Genome representation was comprehensive and estimated to be 99.82% complete, although six regions encompassing a maximum of 5.62 Mb failed to amplify. There was no degradation in the accuracy of SNP genotyping and, in direct sequencing experiments sampling 500,000 bp, the estimated error rate (9.5 x 10(-6)) was the same as in paired unamplified samples. The detection of cancer-associated loss of heterozygosity and copy number changes, including homozygous deletion and gene amplification, were similarly robust. These results suggest that phi29MDA yields high fidelity, near-complete genome representation suitable for high resolution genetic analysis.  相似文献   

16.
This study introduces a DNA microarray-based genotyping system for accessing single nucleotide polymorphisms (SNPs) directly from a genomic DNA sample. The described one-step approach combines multiplex amplification and allele-specific solid-phase PCR into an on-chip reaction platform. The multiplex amplification of genomic DNA and the genotyping reaction are both performed directly on the microarray in a single reaction. Oligonucleotides that interrogate single nucleotide positions within multiple genomic regions of interest are covalently tethered to a glass chip, allowing quick analysis of reaction products by fluorescence scanning. Due to a fourfold SNP detection approach employing simultaneous probing of sense and antisense strand information, genotypes can be automatically assigned and validated using a simple computer algorithm. We used the described procedure for parallel genotyping of 10 different polymorphisms in a single reaction and successfully analyzed more than 100 human DNA samples. More than 99% of genotype data were in agreement with data obtained in control experiments with allele-specific oligonucleotide hybridization and capillary sequencing. Our results suggest that this approach might constitute a powerful tool for the analysis of genetic variation.  相似文献   

17.
As the number of single-nucleotide polymorphism (SNP) screening and other mutation scanning studies have increased explosively, following the development of high-throughput instrumentation, it becomes even more important to have sufficient template DNA. The source of DNA is often limited, especially in epidemiological studies, which require many samples as well as enough DNA to perform numerous SNP screenings or mutation scannings. Therefore, the aim is to solve the problem of stock DNA limitation. This need has been an important reason for the development of whole genome amplification (WGA) methods. Several systems are based on Phi29 polymerase multiple displacement amplification (MDA) or on DNA fragmentation (OmniPlex). Using TaqMan SNP genotyping assays, we have tested four WGA systems -- AmpliQ Genomic Amplifier Kit, GenomiPhi, Repli-g, and GenomePlex -- on DNA extracted from Guthrie cards to evaluate the amplification bias, concordance- and call rates, cost efficiency, and flexibility. All systems successfully amplified picograms of DNA from Guthrie cards to micrograms of product without loss of heterozygosity and with minimal allelic bias. A modified AmpliQ set up was chosen for further evaluation. In all, 2,000 SNP genotyping results from amplified and nonamplified samples were compared and the concordance rates between the samples were 99.7%. The call rate using the TaqMan system was 99.8%. DNA extracted from Guthrie cards and amplified with one of the four evaluated WGA systems is applicable in epidemiological genetic screenings. System choice should be based on requirements for system flexibility, product yield, and use in subsequent analysis.  相似文献   

18.
Yan J  Feng J  Hosono S  Sommer SS 《BioTechniques》2004,37(1):136-8, 140-3
Well-characterized epidemiological resources are generated with great effort, yet associated patient DNA samples can be limiting. The efficacy of the whole genome amplification (WGA) method, termed multiple displacement amplification (MDA), was assessed for detecting heterozygous sequence variants, mutation scanning, and PCR for challenging segments. Fifteen common polymorphisms from 10 genes located on 8 chromosomes were genotyped by direct sequencing of 300 PCR products from 115 high-quality MDA-amplified DNA samples extracted by different methods. The GC content of these analyzed segments ranges from 30% to 69%. Genotyping results demonstrate 100% accuracy. For heterozygotes, the relative intensity of peaks generated by the two alleles is highly similar for genomic and MDA-amplified genomic DNA, independent of GC content. In contrast, one of four heterozygous loci was mistyped when lower quality MDA-amplified DNA samples were used. The results of single-stranded conformation polymorphism (SSCP)-type of mutation scanningfor seven MDA-amplified DNA samples in four genes were concordant with the genomic DNA samples. PCR on MDA-amplified DNA was routinely successful for challenging 10- and 12-kb segments with GC content ranging from 30% to 80%, demonstrating that rather long segments, which are difficult to amplify with PCR, are amplified well with MDA. These results suggest that MDA is an effective method of WGA with utility in molecular epidemiology. Quality control of the MDA-amplified DNA is critical for high performance.  相似文献   

19.
Sperm typing is an effective way to study recombination rate on a fine scale in regions of interest. There are two strategies for the amplification of single meiotic recombinants: repulsion-phase allele-specific PCR and whole genome amplification (WGA). The former can selectively amplify single recombinant molecules from a batch of sperm but is not scalable for high-throughput operation. Currently, primer extension pre-amplification is the only method used in WGA of single sperm, whereas it has limited capacity to produce high-coverage products enough for the analysis of local recombination rate in multiple large regions. Here, we applied for the first time a recently developed WGA method, multiple displacement amplification (MDA), to amplify single sperm DNA, and demonstrated its great potential for producing high-yield and high-coverage products. In a 50 μl reaction, 76 or 93% of loci can be amplified at least 2500- or 250-fold, respectively, from single sperm DNA, and second-round MDA can further offer >200-fold amplification. The MDA products are usable for a variety of genetic applications, including sequencing and microsatellite marker and single nucleotide polymorphism (SNP) analysis. The use of MDA in single sperm amplification may open a new era for studies on local recombination rates.  相似文献   

20.
SNP genotyping on a genome-wide amplified DOP-PCR template   总被引:4,自引:1,他引:3       下载免费PDF全文
With the increasing demand for higher throughput single nucleotide polymorphism (SNP) genotyping, the quantity of genomic DNA often falls short of the number of assays required. We investigated the use of degenerate oligonucleotide primed polymerase chain reaction (DOP-PCR) to generate a template for our SNP genotyping methodology of fluorescence polarization template-directed dye-terminator incorporation detection. DOP-PCR employs a degenerate primer (5′-CCGACTCGAGNNNNNNATGTGG-3′) to produce non-specific uniform amplification of DNA. This approach has been successfully applied to microsatellite genotyping. We compared genotyping of DOP-PCR-amplified genomic DNA to genomic DNA as a template. Results were analyzed with respect to feasibility, allele loss of alleles, genotyping accuracy and storage conditions in a high-throughput genotyping environment. DOP-PCR yielded overall satisfactory results, with a certain loss in accuracy and quality of the genotype assignments. Accuracy and quality of genotypes generated from the DOP-PCR template also depended on storage conditions. Adding carrier DNA to a final concentration of 10 ng/µl improved results. In conclusion, we have successfully used DOP-PCR to amplify our genomic DNA collection for subsequent SNP genotyping as a standard process.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号