首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The paper presents a theoretical model for the response of a tissue-equivalent proportional counter (TEPC) irradiated with charged particles. Heavy ions and iron ions in particular constitute a significant part of radiation in space. TEPCs are used for all space shuttle and International Space Station (ISS) missions to estimate the dose and radiation quality (in terms of lineal energy) inside spacecraft. The response of the tissue-equivalent proportional counters shows distortions at the wall/cavity interface. In this paper, we present microdosimetric investigation using Monte Carlo track structure calculations to simulate the response of a TEPC to charged particles of various LET (1 MeV protons, 2.4 MeV alpha particles, 46 MeV/nucleon 20Ne, 55 MeV/nucleon 20Ne, 45 MeV/nucleon 40Ar, and 1.05 GeV/nucleon 56Fe). Data are presented for energy lost and energy absorbed in the counter cavity and wall. The model calculations are in good agreement with the results of Rademacher et al. (Radiat. Res. 149, 387-389, 1998), including the study of the interface between the wall and the sensitive region of the counter. It is shown that the anomalous response observed at large event sizes in the experiment is due to an enhanced entry of secondary electrons from the wall into the gas cavity.  相似文献   

2.
The radiation environment on board the space shuttle and the International Space Station includes high-Z and high-energy (HZE) particles that are part of the galactic cosmic radiation (GCR) spectrum. Iron-56 particles are considered to be one of the most biologically important parts of the GCR spectrum. Tissue-equivalent proportional counters (TEPCs) are used as active dosimeters on manned space flights. These TEPCs are further used to determine the average quality factor for each space mission. A TEPC simulating a 1-microm-diameter sphere of tissue was exposed as part of a particle spectrometer to (56)Fe particles at energies from 200-1000 MeV/nucleon. The response of TEPCs in terms of mean lineal energy, y(F), and dose mean lineal energy, y(D), as well as the energy deposited at different impact parameters through the detector was determined for six different incident energies of (56)Fe particles in this energy range. Calculations determined that charged-particle equilibrium was achieved for each of the six experiments. Energy depositions at different impact parameters were calculated using a radial dose distribution model, and the results were compared to experimental data.  相似文献   

3.
Waker AJ  Aslam 《Radiation research》2011,175(6):806-813
To improve radiation protection dosimetry for low-energy neutron fields encountered in nuclear power reactor environments, there is increasing interest in modeling neutron energy deposition in metrological instruments such as tissue-equivalent proportional counters (TEPCs). Along with these computational developments, there is also a need for experimental data with which to benchmark and test the results obtained from the modeling methods developed. The experimental work described in this paper is a study of the energy deposition in tissue-equivalent (TE) medium using an in-house built graphite-walled proportional counter (GPC) filled with TE gas. The GPC is a simple model of a standard TEPC because the response of the counter at these energies is almost entirely due to the neutron interactions in the sensitive volume of the counter. Energy deposition in tissue spheres of diameter 1, 2, 4 and 8 μm was measured in low-energy neutron fields below 500 keV. We have observed a continuously increasing trend in microdosimetric averages with an increase in neutron energy. The values of these averages decrease as we increase the simulated diameter at a given neutron energy. A similar trend for these microdosimetric averages has been observed for standard TEPCs and the Rossi-type, TE, spherical wall-less counter filled with propane-based TE gas in the same energy range. This implies that at the microdosimetric level, in the neutron energy range we employed in this study, the pattern of average energy deposited by starter and insider proton recoil events in the gas is similar to those generated cumulatively by crosser and stopper events originating from the counter wall plus starter and insider recoil events originating in the sensitive volume of a TEPC.  相似文献   

4.
The response of a tissue-equivalent proportional counter (TEPC) to different ions having a similar linear energy transfer (LET) has been studied. Three ions, 14N, 20Ne and 28Si, were investigated using the HIMAC accelerator at the National Institute of Radiological Sciences at Chiba, Japan. The calculated linear energy transfer (LET( infinity )) of all ions was 44 +/- 2 keV/microm at the sensitive volume of the TEPC. A particle spectrometer was used to record the charge and position of each incident beam particle. This enabled reconstruction of the location of the track as it passed though the TEPC and ensured that the particle survived without fragmentation. The spectrum of energy deposition events in the TEPC could be evaluated as a function of trajectory through the TEPC. The data indicated that there are many events from particles that did not pass through the sensitive volume. The fraction of these events increased as the energy of the particle increased due to changes in the maximum energy of the delta rays. Even though the LET of the incident particles was nearly identical, the frequency-averaged lineal energy, y(F), as well as the dose-averaged lineal energy, y(D), varied with the velocity of the incident particle. However, both values were within 15% of LET in all cases.  相似文献   

5.
Measurements in nearly monoenergetic beams of 144, 24.5, and 2 keV neutrons and of thermal neutrons have been performed with low-pressure proportional counters. The suitability of a tissue-equivalent proportional counter (TEPC) for dosimetry of low-energy neutrons has been investigated. In contrast to higher neutron energies, the modification of the primary radiation field by the detector wall and the contribution of secondaries produced in the gas are significant. These effects have been investigated by additional measurements with a carbon-walled proportional counter. The various physical processes of neutron interaction with wall and gas of the TEPC have been analyzed, and absorbed dose, kerma, and kerma contributions from the various processes are presented. In addition, dose contributions from contaminating neutrons and photons have been obtained for the calibration fields used. The results have been related to neutron fluence. The comparison with tabulated kerma factors shows excellent agreement, indicating the suitability of the TEPC method for dosimetry of low-energy neutrons.  相似文献   

6.
Experiments have been performed to measure the response of a spherical tissue-equivalent proportional counter (TEPC) and a silicon-based LET spectrometer (RRMD-III) to protons with energies ranging from 50-200 MeV. This represents a large portion of the energy distribution for trapped protons encountered by astronauts in low-Earth orbit. The beam energies were obtained using plastic polycarbonate degraders with a monoenergetic beam that was extracted from a proton synchrotron. The LET spectrometer provided excellent agreement with the expected LET distribution emerging from the energy degraders. The TEPC cannot measure the LET distribution directly. However, the frequency mean value of lineal energy, y(-)(f), provided a good approximation to LET. This is in contrast to previous results for high-energy heavy ions where y(-)(f) underestimated LET, whereas the dose-averaged lineal energy, y(-)(D), provided a good approximation to LET.  相似文献   

7.
One of the risks of prolonged manned space flight is the exposure of astronauts to radiation from galactic cosmic rays, which contain heavy ions such as (56)Fe. To study the effects of such exposures, experiments were conducted at the Brookhaven National Laboratory by exposing Wistar rats to high-mass, high-Z, high-energy (HZE) particles using the Alternating Gradient Synchrotron (AGS). The biological effectiveness of (56)Fe ions (1000 MeV/nucleon) relative to low-LET gamma rays and high-LET alpha particles for the induction of chromosome damage and micronuclei was determined. The mitotic index and the frequency of chromosome aberrations were evaluated in bone marrow cells, and the frequency of micronuclei was measured in cells isolated from the trachea and the deep lung. A marked delay in the entry of cells into mitosis was induced in the bone marrow cells that decreased as a function of time after the exposure. The frequencies of chromatid aberrations and micronuclei increased as linear functions of dose. The frequency of chromosome aberrations induced by HZE particles was about 3.2 times higher than that observed after exposure to (60)Co gamma rays. The frequency of micronuclei in rat lung fibroblasts, lung epithelial cells, and tracheal epithelial cells increased linearly, with slopes of 7 x 10(-4), 12 x 10(-4), and 11 x 10(-4) micronuclei/binucleated cell cGy(-1), respectively. When genetic damage induced by radiation from (56)Fe ions was compared to that from exposure to (60)Co gamma rays, (56)Fe-ion radiation was between 0.9 and 3.3 times more effective than (60)Co gamma rays. However, the HZE-particle exposures were only 10-20% as effective as radon in producing micronuclei in either deep lung or tracheal epithelial cells. Using microdosimetric techniques, we estimated that 32 cells were hit by delta rays for each cell that was traversed by the primary HZE (56)Fe particle. These calculations and the observed low relative effectiveness of the exposure to HZE particles suggest that at least part of the cytogenetic damage measured was caused by the delta rays. Much of the energy deposited by the primary HZE particles may result in cell killing and may therefore be "wasted" as far as production of detectable micronuclei is concerned. The role of wasted energy in studies of cancer induction may be important in risk estimates for exposure to HZE particles.  相似文献   

8.
We have calculated the electronic energy loss of proton and α-particle beams in dry DNA using the dielectric formalism. The electronic response of DNA is described by the MELF-GOS model, in which the outer electron excitations of the target are accounted for by a linear combination of Mermin-type energy-loss functions that accurately matches the available experimental data for DNA obtained from optical measurements, whereas the inner-shell electron excitations are modeled by the generalized oscillator strengths of the constituent atoms. Using this procedure we have calculated the stopping power and the energy-loss straggling of DNA for hydrogen- and helium-ion beams at incident energies ranging from 10 keV/nucleon to 10 MeV/nucleon. The mean excitation energy of dry DNA is found to be I = 81.5 eV. Our present results are compared with available calculations for liquid water showing noticeable differences between these important biological materials. We have also evaluated the electron excitation probability of DNA as a function of the transferred energy by the swift projectile as well as the average energy of the target electronic excitations as a function of the projectile energy. Our results show that projectiles with energy ?100 keV/nucleon (i.e., around the stopping-power maximum) are more suitable for producing low-energy secondary electrons in DNA, which could be very effective for the biological damage of malignant cells.  相似文献   

9.
AimThe aim of this study is simulation of the proton depth-dose distribution and dose evaluation of secondary particles in proton therapy of brain tumor using the GEANT4 and FLUKA Monte Carlo codes.BackgroundProton therapy is a treatment method for variety of tumors such as brain tumor. The most important feature of high energy proton beams is the energy deposition as a Bragg curve and the possibility of creating the spread out Bragg peak (SOBP) for full coverage of the tumor.Materials and methodsA spherical tumor with the radius of 1 cm in the brain is considered. A SNYDER head phantom has been irradiated with 30−130 MeV proton beam energy. A PMMA modulator wheel is used for covering the tumor. The simulations are performed using the GEANT4 and FLUKA codes.ResultsUsing a modulator wheel, the Spread Out Bragg Peak longitudinally and laterally covers the tumor. Flux and absorbed dose of secondary particles produced by nuclear interactions of protons with elements in the head are considerably small compared to protons.ConclusionsUsing 76.85 MeV proton beam and a modulator wheel, the tumor can be treated accurately in the 3-D, so that the distribution of proton dose in the surrounding tissues is very low. The results show that more than 99% of the total dose of secondary particles and protons is absorbed in the tumor.  相似文献   

10.
Fast neutrons (FN) have a higher radio-biological effectiveness (RBE) compared with photons, however the mechanism of this increase remains a controversial issue. RBE variations are seen among various FN facilities and at the same facility when different tissue depths or thicknesses of hardening filters are used. These variations lead to uncertainties in dose reporting as well as in the comparisons of clinical results. Besides radiobiology and microdosimetry, another powerful method for the characterization of FN beams is the calculation of total proton and heavy ion kerma spectra. FLUKA and MCNP Monte Carlo code were used to simulate these kerma spectra following a set of microdosimetry measurements performed at the National Accelerator Centre. The calculated spectra confirmed major classical statements: RBE increase is linked to both slow energy protons and alpha particles yielded by (n,alpha) reactions on carbon and oxygen nuclei. The slow energy protons are produced by neutrons having an energy between 10 keV and 10 MeV, while the alpha particles are produced by neutrons having an energy between 10 keV and 15 MeV. Looking at the heavy ion kerma from <15 MeV and the proton kerma from neutrons <10 MeV, it is possible to anticipate y* and RBE trends.  相似文献   

11.
High-charge and energy (HZE) nuclei represent one of the main health risks for human space exploration, yet little is known about the mechanisms responsible for the high biological effectiveness of these particles. We have used in situ hybridization probes for cross-species multicolor banding (RxFISH) in combination with telomere detection to compare yields of different types of chromosomal aberrations in the progeny of human peripheral blood lymphocytes exposed to either high-energy iron ions or gamma rays. Terminal deletions showed the greatest relative variation, with many more of these types of aberrations induced after exposure to accelerated iron ions (energy 1 GeV/nucleon) compared with the same dose of gamma rays. We found that truncated chromosomes without telomeres could be transmitted for at least three cell cycles after exposure and represented about 10% of all aberrations observed in the progeny of cells exposed to iron ions. On the other hand, the fraction of cells carrying stable, transmissible chromosomal aberrations was similar in the progeny of cells exposed to the same dose of densely or sparsely ionizing radiation. The results demonstrate that unrejoined chromosome breaks are an important component of aberration spectra produced by the exposure to HZE nuclei. This finding may well be related to the ability of such energetic particles to produce untoward late effects in irradiated organisms.  相似文献   

12.
A standardized dichlorofluorescin (DCF) fluorometric assay capable of measuring radiation-induced oxidative stress was used to determine the effectiveness of protons and high-mass, high-atomic number (Z) and high-energy (HZE) particles to produce oxidative stress in vitro. Protons were found to be about equally as effective as X rays in the generation of oxidative stress in cultured cells. However, 56Fe-ion beams with energies of 1 GeV/nucleon and 5 GeV/nucleon were less effective than X rays or gamma rays in inducing dichlorofluorescin (DCFH) oxidation. The relatively lower slope values for the dose responses of HZE-particle radiation-induced DCFH oxidation indicate that the sensitivity of the DCF fluorometric assay is probably dependent on the linear energy transfer (LET) of the radiation beam.  相似文献   

13.
An unusually small (51 KD) IgD myeloma protein was isolated from secretions of TEPC 1017 generation (gen) 24. The delta-chain mRNA and the delta-chain gene in this tumor were compared with those of TEPC 1017 of earlier generations. The gen 24 protein contained one normal-sized kappa-type light chain (21 KD) and one unusually short delta-heavy chain (30 KD). The delta-heavy chain was 15 KD shorter than that of TEPC 1017 of earlier generations, owing to a delta-mRNA (1.15 kb) which was 600 bp shorter than that of TEPC 1017 of earlier generations. TEPC 1017 is a tetraploid tumor, and the gen 24 appears to contain at least two different deletions on different chromosomes. The short mRNA was produced from one of these altered delta-chain genes which had a productive VDJ rearrangement but which had lost the C delta 3 domain and perhaps the C delta H domain as well. Despite these genetic insults, RNA splicing produced delta-mRNA with secreted termini and mRNA with membrane-binding termini. It is suggested that the mouse C delta gene has an unusual predilection for deletions because it normally lacks any vestige of C delta 2 and, during i.p. passage, it suffered further deletions or alterations.  相似文献   

14.
Ionizing radiation induces bistranded clustered damages--two or more abasic sites, oxidized bases and strand breaks on opposite DNA strands within a few helical turns. Since clusters are refractory to repair and are potential sources of double-strand breaks (DSBs), they are potentially lethal and mutagenic. Although induction of single-strand breaks (SSBs) and isolated lesions has been studied extensively, little is known about the factors affecting induction of clusters other than DSBs. To determine whether the type of incident radiation could affect the yields or spectra of specific clusters, we irradiated genomic T7 DNA, a simple 40-kbp linear, blunt-ended molecule, with ion beams [iron (970 MeV/nucleon), carbon (293 MeV/nucleon), titanium (980 MeV/nucleon), silicon (586 MeV/nucleon), protons (1 GeV/nucleon)] or 100 kVp X rays and then quantified DSBs, Fpg-oxypurine clusters and Nfo-abasic clusters using gel electrophoresis, electronic imaging and number average length analysis. The yields (damages/Mbp Gy(-1)) of all damages decreased with increasing linear energy transfer (LET) of the radiation. The relative frequencies of DSBs compared to abasic and oxybase clusters were higher for the charged particles-including the high-energy, low-LET protons-than for the ionizing photons.  相似文献   

15.
PurposeTo determine out-of-field doses produced in proton pencil beam scanning (PBS) therapy using Monte Carlo simulations and to estimate the associated risk of radiation-induced second cancer from a brain tumor treatment.MethodsSimulations of out-of-field absorbed doses were performed with MCNP6 and benchmarked against measurements with tissue-equivalent proportional counters (TEPC) for three irradiation setups: two irradiations of a water phantom using proton energies of 78–147 MeV and 177–223 MeV, and one brain tumor irradiation of a whole-body phantom. Out-of-field absorbed and equivalent doses to organs in a whole-body phantom following a brain tumor treatment were subsequently simulated and used to estimate the risk of radiation-induced cancer. Additionally, the contribution of absorbed dose originating from radiation produced in the nozzle was calculated from simulations.ResultsOut-of-field absorbed doses to the TEPC ranged from 0.4 to 135 µGy/Gy. The average deviation between simulations and measurements of the water phantom irradiations was about 17%. The absorbed dose contribution from radiation produced in the nozzle ranged between 0 and 70% of the total dose; the contribution was however small in absolute terms. The absorbed and equivalent doses to the organs ranged between 0.2 and 60 µGy/Gy and 0.5–151 µSv/Gy. The estimated lifetime risk of radiation-induced second cancer was approximately 0.01%.ConclusionsThe agreement of out-of-field absorbed doses between measurements and simulations was good given the sources of uncertainties. Calculations of out-of-field organ doses following a brain tumor treatment indicated that proton PBS therapy of brain tumors is associated with a low risk of radiation-induced cancer.  相似文献   

16.
The radiation field in deep space contains high levels of high-energy protons and substantially lower levels of high-atomic-number, high-energy (HZE) particles. Calculations indicate that cellular nuclei of human space travelers will be hit during a 3-year Mars mission by approximately 400 protons and approximately 0.4 HZE particles. Thus most cells in astronauts will be hit by a proton(s) before being hit by an HZE particle. To investigate effects of dual ion irradiations on human cells, we irradiated primary human neonatal fibroblasts with protons (1 GeV/nucleon, 20 cGy) followed from 2.5 min to 48 h later by iron or titanium ions (1 GeV/nucleon, 20 cGy) and then measured clonogenic survival and frequency of anchorage-independent growth. This frequency depends on the interval between hydrogen- and iron-ion irradiation, with a critical window between 2.5 min and 1 h producing about three times more anchorage-independent colonies per survivor than expected from simple addition of the two ions separately. The hydrogen-titanium-ion dual-beam irradiation produced similar increases that persisted to approximately 6 h. At longer intervals, anchorage-independent growth frequencies were similar to those expected for additivity. However, irradiation of cells with either an iron or a titanium particle first followed by protons produced only additive levels.  相似文献   

17.
Irradiation, delivered by a synchrotron facility, using a set of highly collimated, narrow and parallel photon beams spaced by 1 mm or less, has been termed Microbeam Radiation Therapy (MRT). The tolerance of healthy tissue after MRT was found to be better than after standard broad X-ray beams, together with a more pronounced response of malignant tissue. The microbeam spacing and transverse peak-to-valley dose ratio (PVDR) are considered to be relevant biological MRT parameters. We investigated the MRT concept for proton microbeams, where we expected different depth-dose profiles and PVDR dependences, resulting in skin sparing and homogeneous dose distributions at larger beam depths, due to differences between interactions of proton and photon beams in tissue. Using the FLUKA Monte Carlo code we simulated PVDR distributions for differently spaced 0.1 mm (sigma) pencil-beams of entrance energies 60, 80, 100 and 120 MeV irradiating a cylindrical water phantom with and without a bone layer, representing human head. We calculated PVDR distributions and evaluated uniformity of target irradiation at distal beam ranges of 60–120 MeV microbeams. We also calculated PVDR distributions for a 60 MeV spread-out Bragg peak microbeam configuration. Application of optimised proton MRT in terms of spot size, pencil-beam distribution, entrance beam energy, multiport irradiation, combined with relevant radiobiological investigations, could pave the way for hypofractionation scenarios where tissue sparing at the entrance, better malignant tissue response and better dose conformity of target volume irradiation could be achieved, compared with present proton beam radiotherapy configurations.  相似文献   

18.
Experimental measurements of the radial restricted linear energy transfer (LETr) for alpha beams of 18.3 MeV/n in tissue-equivalent gas were presented. The radial dose distribution for the alpha beam was deduced from the restricted LET measurements. A differential W value for the alpha particle in the tissue-equivalent gas was also deduced. The result for the differential W value was 29.0 +/- 0.9 eV/ion pair. The radial dose varied according to an inverse-square function with distance from the track center for radii larger than 0.026 micron. The maximum extension of the track, the penumbra radius, as 2.73 +/- 1.67 microns, which was less than predicted by calculations (7-9 microns).  相似文献   

19.
Space radiation, including high-mass, high-Z, high-energy particles (HZE; e.g. (56)Fe), represents a significant health risk for astronauts, and the central nervous system (CNS) may be a vulnerable target. HZE-particle radiation may directly affect neuronal function, or during immunological challenge, it may alter immune system-to-CNS communication. To test these hypotheses, we exposed mice to accelerated iron particles ((56)Fe; 600 MeV/nucleon; 1, 2, 4 Gy; brain only) and 1 month later prepared hippocampal slices to measure the effects of radiation on neurotransmission and synaptic plasticity in CA1 neurons. In a model of immune system-to-CNS communication, these electrophysiological parameters were measured in irradiated mice additionally challenged with the peripheral immunological stressor lipopolysaccharide (LPS) injected intraperitoneally 4 h before the slice preparation. Exposure to (56)Fe particles alone increased dendritic excitability and inhibited plasticity. In control mice (0 Gy), LPS treatment also inhibited synaptic plasticity. Paradoxically, in mice exposed to 2 Gy, the LPS treatment restored synaptic plasticity to levels similar to those found in controls (0 Gy, no LPS). Our results indicate that HZE-particle radiation alters normal electrophysiological properties of the CNS and the hippocampal response to LPS.  相似文献   

20.
DNA fragmentation was studied in the fragment size range 0.023-5.7 Mbp after irradiation of human fibroblasts with iron-ion beams of four different energies, i.e., 200 MeV/nucleon, 500 MeV/nucleon, 1 GeV/nucleon and 5 GeV/nucleon, with gamma rays used as the reference radiation. The double-strand break (DSB) yield (and thus the RBE for DNA DSB induction) of the four iron-ion beams, which have LETs ranging from 135 to 442 keV/mum, does not vary greatly as a function of LET. As a consequence, the variation of the cross section for DSB induction mainly reflects the variation in LET. However, when the fragmentation spectra were analyzed with a simple theoretical tool that we recently introduced, the results showed that spatially correlated DSBs, which are absent after gamma irradiation, increased markedly with LET for the iron-ion beams. This occurred because iron ions produce DNA fragments smaller than 0.75 Mbp with a higher probability than gamma rays (a probability that increases with LET). These sizes include those expected from fragmentation of the chromatin loops with Mbp dimensions. This result does not exclude a correlation at distances smaller than the lower size analyzed here, i.e. 23 kbp. Moreover, the DSB correlation is dependent on dose, decreasing when dose increases; this can be explained with the argument that at increasing dose there is an increasing fraction of fragments produced by DSBs caused by separate, uncorrelated tracks.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号