首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 93 毫秒
1.
BACKGROUND: The application of molecules that fluoresce in the infrared (IR) region to measure cell products would be enhanced by a flow cytometer capable of measuring them. To our knowledge, none exist at this time. Accordingly, we have developed such an instrument. METHODS: A Becton Dickinson LSR flow cytometer was modified to include a small 785-nm IR diode laser the size of a C cell battery with 44-mW output power. The instrument was modified further to accommodate this laser in addition to a 405-nm solid-state laser, a 488-nm air-cooled argon laser, and a 658-nm solid-state laser. Because the IR laser is dangerous to the eye, the laser beams were viewed for optical alignment using a CCD camera and video monitor. An avalanche photodiode was used in place of a photomultiplier tube because its detection sensitivity in the IR region is superior. RESULTS: To assess performance, scatter and fluorescence measurements were made using microspheres that fluoresce in the IR region, and human leukocytes were stained with CD45 biotin followed by a streptavidin conjugated with an IR dye. An avalanche photodiode was 2.3 to 2.8 times more sensitive than a photomultiplier tube for detecting IR fluorescence. Cells stained with CD45 biotin and avidin conjugated with an IR dye could easily be resolved and their fluorescence quantified; there was virtually no autofluorescence. In addition, a lipophilic membrane dye that emits in the IR region was studied. HL60 cells were stained with this dye and they exhibited bright fluorescence intensity. CONCLUSION: A commercial instrument could be modified to accommodate an IR laser for exciting dyes that fluoresce in the IR region. This new capability will extend the range of fluorescence that can be measured by flow cytometry.  相似文献   

2.
Circular dichroism (CD) is an important spectroscopic technique for monitoring chirality and biological macromolecule conformation. However, during a CD measurement, absorbance, light scattering/turbidity, and fluorescence can also be detected. The simultaneous measurement of these different spectral features for a single sample is the basis of a multi-mode optical spectrometer. This allows time-efficient gathering of complementary information and provides a scheme to ensure that CD measurements are reliable. Aspects of circular polarization differential light scattering, pH, and temperature variation of a protein (antibody) solution are described. A procedure to help ensure that CD measurements are reliable is described.  相似文献   

3.
An in vivo microscope system has been developed that can measure fluorescence emission and/or light absorption at up to five wavelengths in a tissue area of 18-30 microns diam while imaging adjacent microcirculatory vessels with a video system. The system also incorporates a computer-controlled stage and data acquisition system for rapid and repeated measurements from a number of tissue sites. The tissue area monitored for fluorescence or absorption can be defined further by a confocal arrangement of the microscope optics. Tests of the system for NADH fluorescence measurements show good agreement between the fluorescence at 450 nm and NADH concentration in vitro and in skeletal muscle. The instrument can also be used simultaneously for spectrophotometric determination of O2 saturation and hematocrit in microcirculatory vessels. In vitro tests indicate suitable accuracy for such measurements. The open architecture and modular arrangement of the instrument facilitates its use for a variety of simultaneous measurements of parenchymal cell and microcirculatory function.  相似文献   

4.
The nanosecond dynamics of the single tryptophan, Trp10, of HPr from Streptomyces coelicolor, HPrsc, has been monitored at different pHs. Time-resolved fluorescence methods and DOSY measurements have been used to map the compactness of the protein. At low pHs, where a molten globule-like species has been described, the correlation times from fluorescence showed an abrupt change as the pH was increased. When the protein was folded (above pH 4), two correlation times were observed, which remained practically constant up to pH 9.5. The long correlation time, around 7.5 ns, corresponds to the global rotational motion of the protein, since this value is in agreement with that determined theoretically from hydrodynamic measurements. The short correlation time, around 1.4 ns, must report on fast movements of the protein segment containing the tryptophan residue. On the other hand, fluorescence lifetimes showed the same abrupt change as the correlation times at low pH, but, in addition, a sigmoidal change with a pKa approximately 4.3 was also observed. On the basis of the modeled structure of HPrsc, this last transition could be due to the proximity of Glu12 to Trp10. The changes monitored by the fluorescence lifetimes agree with those observed previously by steady-state fluorescence, CD, and ANS binding experiments. Taken together, these data suggest a multistate equilibrium during folding of HPrsc starting from low pHs.  相似文献   

5.
The pH dependence of the conformation of a mouse IgG2a, kappa monoclonal antibody (MN12) was investigated by several physical techniques, including fluorescence spectroscopy, near-ultraviolet and far-ultraviolet CD, and electric-field-induced transient birefringence measurements. The intensity of the intrinsic tryptophan fluorescence remained constant in the pH range from 3.5 to 10.0. A conformational alteration in the MN12 molecule was observed in the pH region between pH 3.5 and 2.5, as reflected by a substantial enhancement of the fluorescence quantum yield. This effect was more pronounced at high ionic strengths. The fluorescence emission was unaltered, indicating that the acid-induced conformational state is different from a completely unfolded state. This was confirmed by CD and fluorescence polarisation measurements. Iodide and acrylamide fluorescence quenching studies indicated a gradually increasing accessibility of MN12 tryptophan residues with decreasing pH. At low pH precipitation was observed in the presence of iodide. One rotational relaxation time (0.16-0.18 microseconds) was observed for MN12 by electric-field-induced transient birefringence measurements at low ionic strength. After exposure of MN12 to low pH for 1 h, the relaxation time was increased to 0.23 microseconds; a further increase to 0.30 microseconds was observed after 24 h. The combined results suggest an acid-induced expansion and enhanced flexibility of MN12, which eventually leads to irreversible aggregation.  相似文献   

6.
Sato S  Luisi DL  Raleigh DP 《Biochemistry》2000,39(16):4955-4962
The folding kinetics of the multidomain ribosomal protein L9 were studied using pH jump stopped-flow fluorescence and circular dichroism (CD) in conjunction with guanidine hydrochloride (GdnHCl) jump stopped-flow CD experiments. Equilibrium CD and 1D (1)H NMR measurements demonstrated that the C-terminal domain unfolds below pH 4 while the N-terminal domain remains fully folded. Thus, the N-terminal domain remains folded during the pH jump experiments. The folding rate constant of the C-terminal domain was determined to be 3.5 s(-1) by pH jump experiments conducted in the absence of denaturant using stopped-flow CD and fluorescence. CD-detected GdnHCl jump measurements showed that the N- and C-terminal domains fold independently each by an apparent two-state mechanism. The folding rate constant for the N-terminal domain and the C-terminal domain in the absence of denaturant were calculated to be 760 and 4. 7 s(-1), respectively. The good agreement between the pH jump and the denaturant concentration jump experiments shows that the folding rate of the C-terminal domain is the same whether or not the N-terminal domain is folded. This result suggests that the slow folding of the C-terminal domain is not a consequence of unfavorable interactions with the rest of the protein chain during refolding. This is an interesting result since contact order analysis predicts that the folding rate of the C-terminal domain should be noticeably faster. The folding rate of the isolated N-terminal domain was also measured by stopped-flow CD and was found to be the same as the rate for the domain in the intact protein.  相似文献   

7.
An instrument is described which allows measurements of leaf temperature within about 0.3 C. It consists of a special thermistor probe, a small circuit box, and a standard ammeter. The circuit box can easily be fixed to the meter and contains a battery, which passes 0.3 milliampere through the thermistor, and also contains an integrated circuit amplifier, so that the meter reads 20 C full scale deflection, with ranges adjustable in 10 C steps. Calibration experiments show the superiority of the thermistor leaf thermometer to a thermocouple pressed onto a rubber surface with a resilience resembling that of a leaf.  相似文献   

8.
The mini-rapid-scan-spectrophotometer (Mini-RSS) is a scanning single-beam spectrophotometer that has been patented. It is based on a minimum of reflections and involves exclusively mirrors as beam-deflecting components. This way stray light is minimized, which results in an excellent light-throughput, high dynamics, low cost, compactness and rigidity. The Mini-RSS has been designed as a multi-purpose instrument that allows absorption, transmission, reflection, fluorescence and luminescence measurements in a single-beam mode. Its spectral range extends from the UV and visible spectrum to the IR. This provides for the possibility to measure even optically unfavorable, highly turbid or scattering samples that would be otherwise inaccessible to investigations with commercial spectrophotometers. A miniaturized and very sensitive photomultiplier-module (PM) of high dynamics allows in the visible spectral range absorbance measurements that cover up to four OD units. The Mini-RSS is capable of scanning up to 100 spectra per second with a resolution of 12 bit and 500 points. The linear dispersion is currently 5 nm and the stray light level <0.01%.  相似文献   

9.
The General Fluorescence Plant Meter (GFP-Meter) is a portable spectrofluorometer that utilizes a fiber-optic cable and a leaf clip to gather spectrofluorescence data. In contrast to traditional analytical systems, this instrument allows for the rapid detection and fluorescence measurement of proteins under field conditions with no damage to plant tissue. Here we discuss the methodology of gathering and standardizing spectrofluorescence data from tobacco and canola plants expressing GFP. Furthermore, we demonstrate the accuracy and effectiveness of the GFP-Meter. We first compared GFP fluorescence measurements taken by the GFP-Meter to those taken by a standard laboratory-based spectrofluorometer, the FluoroMax-2. Spectrofluorescence measurements were taken from the same location on intact leaves. When these measurements were tested by simple linear regression analysis, we found that there was a positive functional relationship between instruments. Finally, to exhibit that the GFP-Meter recorded accurate measurements over a span of time, we completed a time-course analysis of GFP fluorescence measurements. We found that only initial measurements were accurate; however, subsequent measurements could be used for qualitative purposes.  相似文献   

10.
In order to characterize the isomerization of serumalbumin in the acidic pH-range equilibrium and kinetic measurements of the intrinsic fluorescence of bovine serumalbumin and human serumalbumin were performed. Additional experiments with modified bovine serumalbumin made use of substituted 1.9 benzoxanthene dyes as SH-specific extrinsic fluorophores. The intrinsic fluorescence (lambda exc = 275 nm) shows a pH-dependent shift of the maximum of fluorescence emissions which correlates with the N in equilibrium F isomerization. This and the acid expansion at pH less than 3.5 is indicated by the pH-dependence of the fluorescence intensity at 350 nm. While tyrosine fluorescence is increased in all steps of the transition, tryptophane fluorescence is decreased in a different way for BSA (2 trp/molecule) and HSA (1 trp/molecule), the latter showing the N in equilibrium F transition only. Combining the tryptophan fluorescence data with the results from the SH-specific modification of BSA the conclusion may be drawn that the tryptophan residues in BSA and the SH-group belong to different domains of the molecule. Stopped-flow experiments prove the N in equilibrium F' and the F' in equilibrium F transitions to be separable along the time axis, the relaxation times being in the range between 40-50 and 300-600 msec respectively. For the "expansion" the kinetic constants critically depend on the initial pH conditions of the solutions. The backward reaction F leads to N seems to be a multistep isomerization process which is characterized by relaxation times greater than 1 sec.  相似文献   

11.
Kinetically-resolved absorbance measurements during extended, or steady-state illumination are typically hindered by large, light-induced changes in the light-scattering properties of the material. In this work, a new type of portable spectrophotometer, the Non-Focusing Optical Spectrophotometer (NoFOSpec), is introduced, which reduces interference from light-scattering changes and is in a form suitable for fieldwork. The instrument employs a non-focusing optical component, called a compound parabolic concentrator (CPC), to simultaneously concentrate and homogeneously diffuse measuring and actinic light (from light-emitting diode sources) onto the leaf sample. Light passing through the sample is then collected and processed using a subsequent series of CPCs leading to a photodiode detector. The instrument is designed to be compact, lightweight and rugged for field work. The pulsed measuring beam allows for high sensitivity (typically < 100 ppm noise) and time resolution (∼ 10 μs) measurements in the visible and near infrared spectral regions. These attributes allow high-resolution measurements of signals associated with energization of the thylakoid membrane (the electrochromic shifting of carotenoid pigments), as well as electron transfer, e.g., the 820-nm changes associated with electron transfer through Photosystem I (PS I). In addition, the instrument can be used as a kinetic fluorimeter, e.g., to measure saturation-pulse fluorescence changes indicative of Photosystem II (PS II) quantum efficiency. The instrument is demonstrated by estimating electron and proton fluxes through the photosynthetic apparatus in an intact tobacco leaf, using respectively the saturation-pulse fluorescence changes and dark-interval relaxation kinetics (DIRK) of the electrochromic shift. A linear relationship was found, confirming our earlier results with the laboratory-based diffused-optics flash spectrophotometer, indicating a constant H+/e stoichiometry for linear electron transfer, and suggesting that cyclic electron flow around PS I is either negligible or proportional to linear electron flow. This type of measurement should be useful under field conditions for estimating the extent of PS I cyclic electron transfer, which is proposed to operate under stressed conditions. This revised version was published online in August 2006 with corrections to the Cover Date.  相似文献   

12.
There is a need for simple and inexpensive methods for genotyping single nucleotide polymorphisms (SNPs) and short insertion/deletion variations (InDels). In this work, I demonstrate that a single-stranded DNA (ssDNA) binding dye can be used as a donor fluorophore for fluorescence resonance energy transfer (FRET). The method presented is a homogenous assay in which detection is based on the FRET from the fluorescence of the ssDNA dye bound to the unmodified detection primer to the fluorescent nucleotide analog incorporated into this detection primer during cyclic template directed primer extension reaction. Collection of the FRET emission spectrum with a scanning fluorescence spectrophotometer allows powerful data analysis. The fluorescence emission signal is modified by the optical properties of the assay vessel. This seems to be a completely neglected parameter. By proper selection of the optical properties of the assay plate one can improve the detection of the fluorescence emission signal.  相似文献   

13.
Measurement of fluorescence quantum yield has become an important tool in the search for new solutions in the development, evaluation, quality control and research of illumination, AV equipment, organic EL material, films, filters and fluorescent probes for bio-industry. Quantum yield is calculated as the ratio of the number of photons absorbed, to the number of photons emitted by a material. The higher the quantum yield, the better the efficiency of the fluorescent material. For the measurements featured in this video, we will use the Hitachi F-7000 fluorescence spectrophotometer equipped with the Quantum Yield measuring accessory and Report Generator program. All the information provided applies to this system. Measurement of quantum yield in powder samples is performed following these steps: 1. Generation of instrument correction factors for the excitation and emission monochromators. This is an important requirement for the correct measurement of quantum yield. It has been performed in advance for the full measurement range of the instrument and will not be shown in this video due to time limitations. 2. Measurement of integrating sphere correction factors. The purpose of this step is to take into consideration reflectivity characteristics of the integrating sphere used for the measurements. 3. Reference and Sample measurement using direct excitation and indirect excitation. 4. Quantum Yield calculation using Direct and Indirect excitation. Direct excitation is when the sample is facing directly the excitation beam, which would be the normal measurement setup. However, because we use an integrating sphere, a portion of the emitted photons resulting from the sample fluorescence are reflected by the integrating sphere and will re-excite the sample, so we need to take into consideration indirect excitation. This is accomplished by measuring the sample placed in the port facing the emission monochromator, calculating indirect quantum yield and correcting the direct quantum yield calculation. 5. Corrected quantum yield calculation. 6. Chromaticity coordinates calculation using Report Generator program. The Hitachi F-7000 Quantum Yield Measurement System offer advantages for this application, as follows: High sensitivity (S/N ratio 800 or better RMS). Signal is the Raman band of water measured under the following conditions: Ex wavelength 350 nm, band pass Ex and Em 5 nm, response 2 sec), noise is measured at the maximum of the Raman peak. High sensitivity allows measurement of samples even with low quantum yield. Using this system we have measured quantum yields as low as 0.1 for a sample of salicylic acid and as high as 0.8 for a sample of magnesium tungstate. Highly accurate measurement with a dynamic range of 6 orders of magnitude allows for measurements of both sharp scattering peaks with high intensity, as well as broad fluorescence peaks of low intensity under the same conditions. High measuring throughput and reduced light exposure to the sample, due to a high scanning speed of up to 60,000 nm/minute and automatic shutter function. Measurement of quantum yield over a wide wavelength range from 240 to 800 nm. Accurate quantum yield measurements are the result of collecting instrument spectral response and integrating sphere correction factors before measuring the sample. Large selection of calculated parameters provided by dedicated and easy to use software. During this video we will measure sodium salicylate in powder form which is known to have a quantum yield value of 0.4 to 0.5.  相似文献   

14.
An instrument for optical waveguide lightmode spectroscopy (OWLS) was designed and developed for measurements at different and controlled temperatures in a range of 15 degrees C around room temperature. The instrument allows to scan the waveguide modes at different wavelengths on the same optical chip using different lasers. This instrument was used to monitor DMPC lipid bilayer main phase transition around the critical temperature. The main problem in these experiments is that the OWLS measurements do not give enough information about an optically anisotropic system like a lipid bilayer. Experimental OWLS data at two different wavelengths can however approximately solve the problem. The temperature dependence of the thickness and the refractive indices (ordinary and extraordinary) for the lipid bilayer around the phase transition is presented. (A theoretical derivation of the extraordinary refractive index is given in.)  相似文献   

15.
A coupled two-step reaction of Ellman's reagent (5,5′-dithiobis(2-nitrobenzoic acid)) with excess thioglycerol produces a progress curve composed of two superimposed exponentials. The ratio of the two pseudo-first-order rate constants equals 22.5 and does not vary appreciably with ehanges of either pH value or temperature. Because the ratio of the two amplitudes is defined by the ratio of the rate constants, the reaction can be used to estimate both the apparent zero time of mixing (or the dead time) and the detector linearity of a stopped-flow instrument with a single mixing experiment. The reaction is used as a standard of performance for both absorbance and fluorescence measurements with a stopped-flow spectrophotometer.  相似文献   

16.
An instrument is described which functions as a spectrophotometer, In addition it measures action spectra of photobiological processes, excitation and emission spectra of fluorescence, and gives data for calculation of action spectra of partial reactions of photosynthesis and photocontrolled enzymatic reactions. The instrument has a Bausch and Lomb 250 mm grating monochromator. Equal numbers of quanta at different wavelengths are adjusted electronically with control of the slit through a quantacorrected photocell and a servo motor which is programmed by a cam connected to the wavelength drive.  相似文献   

17.
An instrumental device is described which allows steady-state kinetic measurements of photophosphorylation at a desired proton gradient which can be maintained throughout the course of the experiment ('delta pH clamp'). This is achieved by electronic regulation of light intensity using the calibrated 9-aminoacridine fluorescence signal as sensor of the gradient. The instrument is suitable for determination of kinetic parameters of the proton-translocating ATPase in isolated envelope-free chloroplasts under defined conditions. At clamped delta pH, phosphorylation as a function of substrate concentration shows Michaelis-Menten kinetics. The true Michaelis constants and the dissociation constants for phosphate and ADP are reported. The Michaelis constants are not affected by the magnitude of the proton gradient in the investigated range. The significance of these results is discussed.  相似文献   

18.
2-Aminopurine (P) is a mutagen causing A.T to G.C transitions in prokaryotic systems. To study the base-pairing schemes between P and cytosine (C) or thymine (T), two self-complementary dodecamers containing P paired with either C or T were synthesized, and their protonation equilibria were studied by acid-base titrations and melting experiments. The mismatches were incorporated into the self-complementary sequence d(CGCPCCGGXGCG), where X was C or T. Spectroscopic data obtained from molecular absorption, circular dichroism (CD), and molecular fluorescence spectroscopy were analyzed by a factor-analysis-based method, multivariate curve resolution based on the alternating least squares optimization procedure (MCR-ALS). This procedure allows determination of the number of acid-base species or conformations present in an acid-base or melting experiment and the resolution of the concentration profiles and pure spectra for each of them. Acid-base experiments have shown that at pH 7, 150 mM ionic strength, and 37 degrees C, both C and P are deprotonated. At pH near 4, the majority of species shows C protonated and P deprotonated. Finally, at pH values near 3, the majority of species shows both protonated C and P. These results are in agreement with NMR studies showing a wobble geometry for the P x C base pair and a Watson-Crick geometry for the P x T base pair at neutral pH. Melting experiments were carried out to confirm the proposed acid-base distribution profile. For the sequence including the P x T mismatch, only one transition was observed at neutral pH. However, for the sequence including the P x C mismatch, two transitions were detected by CD but only one by molecular absorption. This behavior agrees with that observed by other authors for oligonucleotides of similar sequence and suggests the following sequence of conformational changes during melting: duplex --> hairpin --> random coil.  相似文献   

19.
BACKGROUND: Fluorescence lifetime microscopy (FLIM) is currently one of the best techniques to perform accurate measurements of interactions in living cells. It is independent of the fluorophore concentration, thus avoiding several common artifacts found in F?rster Resonance Energy Transfer (FRET) imaging. However, for FLIM to achieve high performance, a rigorous instrumental setup and characterization is needed. METHODS: We use known fluorophores to perform characterization experiments in our instrumental setup. This allows us to verify the accuracy of the fluorescence lifetime determination, and test the linearity of the instrument by fluorescence quenching. RESULTS: We develop and validate here a protocol for rigorous characterization of time-domain FLIM instruments. Following this protocol, we show that our system provides accurate and reproducible measurements. We also used HeLa cells expressing proteins fused to Green Fluorescent Proteins variants (CFP and YFP) to confirm its ability to detect interactions in living cells by FRET. CONCLUSIONS: We report a well-designed protocol in which precise and reproducible lifetime measurements can be performed. It is usable for all confocal-based FLIM instruments and is a useful tool for anyone who wants to perform quantitative lifetime measurements, especially when studying interactions in living cells using FRET.  相似文献   

20.
Two methods to combine fluorescence correlation spectroscopy (FCS) with modulated excitation, in a way that allows extraction of correlation data for all correlation times have been developed and experimentally verified. One method extracts distortion-free correlation data from measurements acquired with standard hardware correlators provided the fluorescence does not change systematically within the excitation pulses. This restriction does not apply to the second method, which, however, requires time-resolved acquisition of the fluorescence intensity. Modulation of the excitation in an FCS experiment is demonstrated to suppress triplet population buildup more efficiently than a corresponding reduction in continuous wave excitation intensity (shown for the dye rhodamine 6G in aqueous solution). Excitation modulation thus offers an additional means to optimize the FCS measurement conditions with respect to the photophysical properties of the dyes used. This possibility to suppress photoinduced states also provides a useful tool to distinguish additional processes occurring in the same time regime in the FCS measurements, as demonstrated here for the protonation kinetics of fluorescein at different pH. In general, the proposed concept opens for FCS measurements with a complete correlation timescale in a range of applications where a modulated excitation is either necessary or brings specific advantages.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号