首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Protein chemistry, such as crosslinking and photoaffinity labeling, in combination with modern mass spectrometric techniques, can provide information regarding protein–protein interactions beyond that normally obtained from protein identification and characterization studies. While protein crosslinking can make tertiary and quaternary protein structure information available, photoaffinity labeling can be used to obtain structural data about ligand–protein interaction sites, such as oligonucleotide–protein, drug–protein and protein–protein interaction. In this article, we describe mass spectrometry-based photoaffinity labeling methodologies currently used and discuss their current limitations. We also discuss their potential as a common approach to structural proteomics for providing 3D information regarding the binding region, which ultimately will be used for molecular modeling and structure-based drug design.  相似文献   

2.
Protein chemistry, such as crosslinking and photoaffinity labeling, in combination with modern mass spectrometric techniques, can provide information regarding protein-protein interactions beyond that normally obtained from protein identification and characterization studies. While protein crosslinking can make tertiary and quaternary protein structure information available, photoaffinity labeling can be used to obtain structural data about ligand-protein interaction sites, such as oligonucleotide-protein, drug-protein and protein-protein interaction. In this article, we describe mass spectrometry-based photoaffinity labeling methodologies currently used and discuss their current limitations. We also discuss their potential as a common approach to structural proteomics for providing 3D information regarding the binding region, which ultimately will be used for molecular modeling and structure-based drug design.  相似文献   

3.
MOTIVATION: High-resolution mass spectrometers generate large data files that are complex, noisy and require extensive processing to extract the optimal data from raw spectra. This processing is readily achieved in software and is often embedded in manufacturers' instrument control and data processing environments. However, the speed of this data processing is such that it is usually performed off-line, post data acquisition. We have been exploring strategies that would allow real-time advanced processing of mass spectrometric data, making use of the reconfigurable computing paradigm, which exploits the flexibility and versatility of Field Programmable Gate Arrays (FPGAs). This approach has emerged as a powerful solution for speeding up time-critical algorithms. We describe here a reconfigurable computing solution for processing raw mass spectrometric data generated by MALDI-ToF instruments. The hardware-implemented algorithms for de-noising, baseline correction, peak identification and deisotoping, running on a Xilinx Virtex 2 FPGA at 180 MHz, generate a mass fingerprint over 100 times faster than an equivalent algorithm written in C, running on a Dual 3 GHz Xeon workstation.  相似文献   

4.
The bioinformatic tool GlycosidIQ was developed for computerized interpretation of oligosaccharide mass spectrometric fragmentation based on matching experimental data with theoretically fragmented oligosaccharides generated from the database GlycoSuiteDB. This use of the software for glycofragment mass fingerprinting obviates a large part of the manual, labor intensive, and technically challenging interpretation of oligosaccharide fragmentation. Using 130 negative ion electrospray ionization-tandem mass spectrometry fragment spectra from identified oligosaccharide structures, it was shown that the GlycosidIQ scoring algorithms were able to correctly identify oligosaccharides in the great majority of cases (correct structure top ranked in 78% of the cases and an additional 17% were ranked second highest in the sample set).  相似文献   

5.
All major fragment ions of codeine and morphine were elucidated using LC-electrospray MS/MS and high resolution FT-ICR-MS combined with an IRMPD system. Nanogram quantities of labeled codeine were isolated and purified from Papaver somniferum seedlings, which were grown for up to 9 days in the presence of [ring-13C6]-l-tyrosine, [ring-13C6]-tyramine and [1,2-13C2], [6-O-methyl 13C]-(R,S)-coclaurine. The labeling degree of codeine up to 57% into morphinans was observed.  相似文献   

6.
We have developed a tool for computer-assisted assignments of protein NMR spectra from triple resonance data. The program is designed to resemble established manual assignment procedures as closely as possible. IBIS exports its results in XEASY format. Thus, using IBIS the operator has continuous visual and accounting control over the progress of the assignment procedure. IBIS achieves complete assignments for those residues that exhibit sequential triple resonance connectivities within a few hours or days.  相似文献   

7.
Shotgun proteomics yields tandem mass spectra of peptides that can be identified by database search algorithms. When only a few observed peptides suggest the presence of a protein, establishing the accuracy of the peptide identifications is necessary for accepting or rejecting the protein identification. In this protocol, we describe the properties of peptide identifications that can differentiate legitimately identified peptides from spurious ones. The chemistry of fragmentation, as embodied in the 'mobile proton' and 'pathways in competition' models, informs the process of confirming or rejecting each spectral match. Examples of ion-trap and tandem time-of-flight (TOF/TOF) mass spectra illustrate these principles of fragmentation.  相似文献   

8.
A computer algorithm is described that utilizes both Edman and mass spectrometric data for simultaneous determination of the amino acid sequences of several peptides in a mixture. Gas phase sequencing of a peptide mixture results in a list of observed amino acids for each cycle of Edman degradation, which by itself may not be informative and typically requires reanalysis following additional chromatographic steps. Tandem mass spectrometry, on the other hand, has a proven ability to analyze sequences of peptides present in mixtures. However, mass spectrometric data may lack a complete set of sequence-defining fragment ions, so that more than one possible sequence may account for the observed fragment ions. A combination of the two types of data reduces the ambiguity inherent in each. The algorithm first utilizes the Edman data to determine all hypothetical sequences with a calculated mass equal to the observed mass of one of the peptides present in the mixture. These sequences are then assigned figures of merit according to how well each of them accounts for the fragment ions in the tandem mass spectrum of that peptide. The program was tested on tryptic and chymotryptic peptides from hen lysozyme, and the results are compared with those of another computer program that uses only mass spectral data for peptide sequencing. In order to assess the utility of this method the program is tested using simulated mixtures of varying complexity and tandem mass spectra of varying quality.  相似文献   

9.
The isotopomer distributions of metabolites are invaluable pieces of information in the computation of the flux distribution in a metabolic network. We describe the use of tandem mass spectrometry with the daughter ion scanning technique in the discovery of positional isotopomer distributions (PID). This technique increases the possibilities of mass spectrometry since given the same fragment ions, it uncovers more information than the full scanning mode. The mathematics of the new technique is slightly more complicated than the techniques needed by full scanning mode methods. Our experiments, however, show that in practice the inadequacy of the fragmentation of amino acids in the tandem mass spectrometer does not allow uncovering the PID exactly even if the daughter ion scanning is used. The computational techniques have been implemented in a MATLAB application called PIDC (Positional Isotopomer Distribution Calculator).  相似文献   

10.
The interpretation of mass spectrometry data for protein identification has become a vital component of proteomics research. However, since most existing software tools rely on protein databases, their success is limited, especially as the pace of annotation efforts fails to keep pace with sequencing. We present a publicly available, web-based version of a software tool that maps peptide mass fingerprint data directly to their genomic origin, allowing for genome-based, annotation-independent protein identification.  相似文献   

11.
Mass peak alignment (ion-wise alignment) has recently become a popular method for unsupervised data analysis in untargeted metabolic profiling. Here we present MSClust-a software tool for analysis GC-MS and LC-MS datasets derived from untargeted profiling. MSClust performs data reduction using unsupervised clustering and extraction of putative metabolite mass spectra from ion-wise chromatographic alignment data. The algorithm is based on the subtractive fuzzy clustering method that allows unsupervised determination of a number of metabolites in a data set and can deal with uncertain memberships of mass peaks in overlapping mass spectra. This approach is based purely on the actual information present in the data and does not require any prior metabolite knowledge. MSClust can be applied for both GC-MS and LC-MS alignment data sets. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1007/s11306-011-0368-2) contains supplementary material, which is available to authorized users.  相似文献   

12.
13.
We describe a method for assessing the quality of mass spectra and improving reliability of relative ratio estimations from (18)O-water labeling experiments acquired from low resolution mass spectrometers. The mass profiles of heavy and light peptide pairs are often affected by artifacts, including coeluting contaminant species, noise signal, instrumental fluctuations in measuring ion position and abundance levels. Such artifacts distort the profiles, leading to erroneous ratio estimations, thus reducing the reliability of ratio estimations in high throughput quantification experiments. We used support vector machines (SVMs) to filter out mass spectra that deviated significantly from expected theoretical isotope distributions. We built an SVM classifier with a decision function that assigns a score to every mass profile based on such spectral features as mass accuracy, signal-to-noise ratio, and differences between experimental and theoretical isotopic distributions. The classifier was trained using a data set obtained from samples of mouse renal cortex. We then tested it on protein samples (bovine serum albumin) mixed in five different ratios of labeled and unlabeled species. We demonstrated that filtering the data using our SVM classifier results in as much as a 9-fold reduction in the coefficient of variance of peptide ratios, thus significantly improving the reliability of ratio estimations.  相似文献   

14.
Zhao Y  Lin YH 《Proteomics》2005,5(4):853-855
Instead of using the probability mean, a simple and yet effective heuristic approach was employed to treat experimentally obtained tandem mass spectrometry (MS/MS) data for protein identification. The proposed approach is based on the total number (T) of identified experimental MS/MS data. To warrant the subsequent ranking, the total number of identified b- and y-type ions (Tb+y) must be greater than 50% of T. Peptides having the same T and Tb+y are either ranked by the contiguity of identified ions or discarded during identification. When compared to other protein identification tools, good agreement with the searched results was seen.  相似文献   

15.

Background  

Extracting and visualizing of protein-protein interaction (PPI) from text literatures are a meaningful topic in protein science. It assists the identification of interactions among proteins. There is a lack of tools to extract PPI, visualize and classify the results.  相似文献   

16.
17.
The combination of high accuracy, sensitivity and speed of single and multiple-stage mass spectrometric analyses enables the collection of comprehensive sets of data containing detailed information about complex biological samples. To achieve these properties, we combined two high-performance matrix-assisted laser desorption ionization mass analyzers in one modular mass spectrometric tool, and applied this tool for dissecting the composition and post-translational modifications of protein complexes. As an example of this approach, we here present studies of the Saccharomyces cerevisiae anaphase-promoting complexes (APC) and elucidation of phosphorylation sites on its components. In general, the modular concept we describe could be useful for assembling mass spectrometers operating with both matrix-assisted laser desorption ionization (MALDI) and electrospray ionization (ESI) ion sources into powerful mass spectrometric tools for the comprehensive analysis of complex biological samples.  相似文献   

18.
13C metabolic flux analysis (MFA) is a well-established tool in Metabolic Engineering that found numerous applications in recent years. However, one strong limitation of the current method is the requirement of an-at least approximate-isotopic stationary state at sampling time. This requirement leads to a principle lower limit for the duration of a 13C labeling experiment. A new methodological development is based on repeated sampling during the instationary transient of the 13C labeling dynamics. The statistical and computational treatment of such instationary experiments is a completely new terrain. The computational effort is very high because large differential equations have to be solved and, moreover, the intracellular pool sizes play a significant role. For this reason, the present contribution works out principles and strategies for the experimental design of instationary experiments based on a simple example network. Hereby, the potential of isotopically instationary experiments is investigated in detail. Various statistical results on instationary flux identifiability are presented and possible pitfalls of experimental design are discussed. Finally, a framework for almost optimal experimental design of isotopically instationary experiments is proposed which provides a practical guideline for the analysis of large-scale networks.  相似文献   

19.
20.
This paper introduces the genome annotating proteomic pipeline (GAPP), a totally automated publicly available software pipeline for the identification of peptides and proteins from human proteomic tandem mass spectrometry data. The pipeline takes as its input a series of MS/MS peak lists from a given experimental sample and produces a series of database entries corresponding to the peptides observed within the sample, along with related confidence scores. The pipeline is capable of finding any peptides expected, including those that cross intron-exon boundaries, and those due to single nucleotide polymorphisms (SNPs), alternate splicing, and post-translational modifications (PTMs). GAPP can therefore be used to re-annotate genomes, and this is supported through the inclusion of a Distributed Annotation System (DAS) server, which allows the peptides identified by the pipeline to be displayed in their genomic context within the Ensembl genome browser. GAPP is freely available via the web, at www. gapp.info.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号