首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 125 毫秒
1.
We report the investigation of label-free protein detection directly from lysed cells using microcantilever sensors. The integration of an internally referenced microcantilever sensor combined with peptide aptamer technology enables scalable and label-free detection of proteins from a complex biological environment (e.g. cell lysate). The internally referenced microcantilever sensor was found to be effective in minimizing both the effects of thermal drift and non-specific binding interactions with the backside of the cantilever, thereby allowing protein detection in a complex biological background. Highly specific peptide aptamers are used to modify the cantilever surface to specifically detect less than 80nM CDK2 protein from yeast cell lysate. This binding of CDK2 on the microcantilever generates a tensile surface stress of average magnitude equal to 70+/-22mN/m. Similar experiments conducted with quartz crystal microbalance (QCM) technology are consistent with the response observed using microcantilever sensors.  相似文献   

2.
Microcantilever biosensors   总被引:12,自引:0,他引:12  
Biosensors are sensors in which biomolecular interactions are used as sensing reactions. Biomolecular interactions, when combined with a microcantilever platform, can produce an extremely powerful biosensing design. The resonance frequency of a microcantilever shifts sensitively due to mass loading from molecular interaction as in the case of any acoustic sensors. In addition, the microcantilevers also undergo bending if the molecular adsorption is confined to a single surface of a microcantilever. This cantilever bending is due to a differential surface stress caused by the forces involved in the adsorption process and is amplified by making the cantilever surfaces chemically different. Lack of specificity, the main disadvantage of the cantilevers, can be overcome by using the extremely selective biochemical reactions such as receptor-ligand, antibody-antigen, or enzyme-substrate reactions. Here we review the microcantilever technology and discuss a number of highly sensitive biochemical sensor applications based on microcantilevers.  相似文献   

3.
We developed a field-effect transistor (FET)-based enzyme sensor that detects an enzyme-catalyzed redox-reaction event as an interfacial potential change on an 11-ferrocenyl-1-undecanethiol (11-FUT) modified gold electrode. While the sensitivity of ion-sensitive FET (ISFET)-based enzyme sensors that detect an enzyme-catalyzed reaction as a local pH change are strongly affected by the buffer conditions such as pH and buffer capacity, the sensitivity of the proposed FET-based enzyme sensor is not affected by them in principle. The FET-based enzyme sensor consists of a detection part, which is an extended-gate FET sensor with an 11-FUT immobilized gold electrode, and an enzyme reaction part. The FET sensor detected the redox reaction of hexacyanoferrate ions, which are standard redox reagents of an enzymatic assay in blood tests, as a change in the interfacial potential of the 11-FUT modified gold electrode in accordance with the Nernstian response at a slope of 59 mV/decade at 25 degrees C. Also, the FET sensor had a dynamic range of more than five orders and showed no sensitivity to pH. A FET-based enzyme sensor for measuring cholesterol level was constructed by adding an enzyme reaction part, which contained cholesterol dehydrogenase and hexacyanoferrate (II)/(III) ions, on the 11-FUT modified gold electrode. Since the sensitivity of the FET sensor based on potentiometric detection was independent of the sample volume, the sample volume was easily reduced to 2.5 microL while maintaining the sensitivity. The FET-based enzyme sensor successfully detected a serum cholesterol level from 33 to 233 mg/dL at the Nernstian slope of 57 mV/decade.  相似文献   

4.
We reported that peptide could be utilized as receptor molecule in the gas phase for application in micro/nano sensors by using a specific peptide that recognizes 2,4-dinitrotoluene at room temperature and in an atmospheric environment and measuring changes in the resonant frequency of the peptide immobilized microcantilevers. By using these peptides as receptors on a microcantilever sensor, we were able to experimentally detect 2,4-dinitrotoluene (DNT) vapor at concentrations as low as parts per billion (ppb) in the gas phase. While resonant frequency changes after binding between 2,4-DNT and the specific peptide receptor that was immobilized on microcantilevers were observed, the resonant frequency of DNT nonspecific peptide immobilized microcantilever did not change when exposed to 2,4-DNT vapor. The limit of detection (LOD) was calculated to be 431 ppt of limit of detection is numerically expected by experimental based on an equation that describes the relationship between the noise-equivalent analyte concentration. These results indicate that the peptide receptors hold great promise for use in the development of an artificial olfactory system and electronic nose based on micro/nanotechnology for monitoring various chemical vapors in the gas phase such as explosive mixtures of chemicals and/or volatile organic compounds.  相似文献   

5.
生物光学传感器是一种对生物物质敏感并将其浓度转换为光信号,再由光电器件转换成电信号进行检测的仪器。由于随着微加工技术和纳米技术的进步,生物光学传感器将不断的微型化,各种便携式生物光学传感器的出现使得人们在家中进行疾病诊断、在市场上直接检测食品及在野外快速检测环境污染成为可能。便携式生物光学传感器一般由光源、光学通路和光电元件三部分组成。传感器结构中各个组件的优化处理将有利于检测设备在实际运用中的便利性和在复杂环境中的适用性,同时也有利于提高生物检测的灵敏度。主要从激励光源的选择、生物光学检测的原理、用于传感光源分析的半导体光敏元件3方面,描述近年来常见的便携式生物光学传感器的研究进展。未来生物检测器件将趋于成本低廉、便携快捷、智能高效等特点,基于生物光学反应特性的研究和传感器结构制备的优化将使得便携式生物光学传感器在未来传感检测应用中具有巨大的商业价值和广泛的实用价值。  相似文献   

6.
We report a biosensor based on a microcantilever that is modified by a specific peptide for highly selective detection of trimethylamine (TMA). The assay is based on binding-induced bending of the peptide functionalized microcantilevers. The sensor is selectively responsive to TMA. The amplitude of microcantilever bending at equilibrium is a function of the concentration of TMA with a dynamic range from 8 ppm to 800 ppm. The detection limit is approximately 8 ppm. There is a good intra-sensor and an acceptable inter-sensor reproducibility as evidenced by the standard deviation of 5% and 15%, respectively.  相似文献   

7.
微悬臂列阵传感器在生物检测方面具有快速、痕量和非标记的特性. 我们以镀金并在其上固定了 DNA 探针的微悬臂为正极,在靶杂交液槽内引入另一电极作为负极,构成电场驱动微悬臂 DNA 生物传感器. 对该传感器系统施加静电场,驱动 DNA 分子朝正极迁移,使溶液中的 DNA 分子富集在微悬臂上,促进 DNA 分子的杂交. 结果表明: a. DNA 在微悬臂上的杂交时间仅需 3 min,加快了微悬臂生物传感器对 DNA 分子的检测速度; b. 提高了微悬臂生物传感器的灵敏度,可以检测到皮克级的 DNA 分子.  相似文献   

8.
Air pollution is a severe concern globally as it disturbs the health conditions of living beings and the environment because of the discharge of acetone molecules. Metal oxide semiconductor (MOS) nanomaterials are crucial for developing efficient sensors because of their outstanding chemical and physical properties, empowering the inclusive developments in gas sensor productivity. This review presents the ZnO nanostructure state of the art and notable growth, and their structural, morphological, electronic, optical, and acetone-sensing properties. The key parameters, such as response, gas detection limit, sensitivity, reproducibility, response and recovery time, selectivity, and stability of the acetone sensor, have been discussed. Furthermore, gas-sensing mechanism models based on MOS for acetone sensing are reported and discussed. Finally, future possibilities and challenges for MOS (ZnO)-based gas sensors for acetone detection have also been explored.  相似文献   

9.
Automatic detection of clinical mastitis is an essential part of high performance and robotic milking. Currently available technology (conductivity monitoring) is unable to achieve acceptable specificity or sensitivity of detection of clinical mastitis or other clinical diseases. Arrays of sensors with high cross-sensitivity have been successfully applied for recognition and quantitative analysis of other multicomponent liquids. An experiment was conducted to determine whether a multisensor system ("electronic tongue") based on an array of chemical sensors and suitable data processing could be used to discriminate between milk secretions from infected and healthy glands. Measurements were made with a multisensor system of milk samples from two different farms in two experiments. A total of 67 samples of milk from both mastitic and healthy glands were in two sets. It was demonstrated that the multisensor system could distinguish between control and clinically mastitic milk samples (p=0.05). The sensitivity and specificity of the sensor system (93 and 96% correspondingly) showed an improvement over conductivity (56 and 82% correspondingly). The multisensor system offers a novel method of improving mastitis detection.  相似文献   

10.
Comprehensive identification of chemical contaminants in Army field water supplies can be a lengthy process, but rapid analytical methods suitable for field use are limited. A complementary approach is to directly measure toxicity instead of individual chemical constituents. Ten toxicity sensors utilizing enzymes, bacteria, or vertebrate cells were tested to determine the minimum number of sensors that could rapidly identify toxicity in water samples containing one of 12 industrial chemicals. The ideal sensor would respond at a concentration just exceeding the Military Exposure Guideline (MEG) level for the chemical (an estimated threshold for adverse effects) but below the human lethal concentration. Chemical solutions were provided to testing laboratories as blind samples. No sensors responded to deionized water blanks, and only one sensor responded to a hard water blank. No single toxicity sensor responded to more than six chemicals in the desired response range, and one chemical (nicotine) was not detected by any sensor with the desired sensitivity. A combination of three sensors (Microtox, the Electric Cell Substrate Impedance Sensing (ECIS) test, and the Hepatocyte low density lipoprotein (LDL) uptake test) responded appropriately to nine of twelve chemicals. Adding a fourth sensor (neuronal microelectrode array) to the test battery allowed detection of two additional chemicals (aldicarb and methamidophos), but the neuronal microelectrode array was overly sensitive to paraquat. Evaluating sensor performance using a standard set of chemicals and a desired sensitivity range provides a basis both for selecting among available toxicity sensors and for evaluating emerging sensor technologies. Recommendations for future toxicity sensor evaluations are discussed.  相似文献   

11.
Electroenzymatic glucose sensors implanted into sub-cutaneous (s.c.) tissue of human subjects and experimental animals exhibit lower sensitivities to glucose than in buffer solutions before implantation. The mechanism of the decrease of sensitivity is not known. Sensors used in this study were fabricated from platinum wires (diameter 0.125 mm) with covalently bound glucose oxidase at the tip of the wire. After coating the tip with polyurethane, wires were placed into 27 gauge steel needles. Sensors were operated potentiostatically at 700 mV against Ag/AgCl pseudo-reference electrodes. These sensors were implanted s.c. in 6 diabetic patients for 7 h. In 4 patients, sensors were responsive to successive increases of plasma glucose levels. Mean sensitivity to glucose in s.c. tissue was 29% of in vitro sensitivity. In 2 patients there was a sudden decrease of sensor currents, unrelated to glucose, shortly after implantation. Sensors were inhibited in human plasma to a similar extent. When sensors were exposed to native plasma and to plasma ultrafiltrate (mol. wt. <10 kDa) for 10 h, identical decreases of signals were found. Exposure to dialysed plasma (mol. wt. >12 kDa) caused much less decrease of sensor signals. Losses of sensor sensitivities to glucose in s.c. tissue and in plasma were totally reversible upon re-exposure of sensors to buffer solutions. We conclude that sensor inactivation in plasma and possibly in s.c. tissue is caused by low molecular weight substances not retained by the polyurethane membrane.  相似文献   

12.
A novel design and fabrication method of glucose sensors based on high aspect ratio carbon post-microarrays is reported in this paper. Apart from the fact that carbon has a wide electrochemical stability window, a major advantage of using carbon post-microarrays as working electrodes for an amperometric glucose sensor is the large reactive surface per unit footprint substrate area, improving sensitivity of the glucose sensor. The carbon post-microarrays were fabricated by carbon-microelectromechanical systems (C-MEMS) technology. Immobilization of enzyme onto the carbon post-electrodes was carried out through co-deposition of glucose oxidase (GOx) and electrochemically polymerized polypyrrole (PPy). Sensing performance of the glucose sensors with different post-heights and various post-densities was tested and compared. The carbon post-glucose sensors show a linear range from 0.5 mM to 20 mM and a response time of about 20 s, which are comparable to the simulation result. Sensitivity per unit footprint substrate area as large as 2.02 mA/(mM cm2) is achieved with the 140 μm high (aspect ratio around 5:1) carbon post-samples, which is two times the sensitivity per unit footprint substrate area of the flat carbon films. This result is consistent with the hypothesis that the number of reaction sites scales with the reactive surface area of the sensor. Numerical simulation based on enzymatic reaction and glucose diffusion kinetics gives the optimum geometric design rules for the carbon post-glucose sensor. Glucose sensors with even higher sensitivity can be achieved utilizing higher carbon post-microarrays when technology evolution will permit it.  相似文献   

13.
We present an acoustic Love-wave biosensor for detection of the Bacillus anthracis simulant, Bacillus thuringiensis at or below inhalational infectious levels. The present work is an experimental study of 36 degrees YX cut LiTaO3 based Love-wave devices for detection of pathogenic spores in aqueous conditions. Given that the detection limit (D1) of Love-wave-based sensors is a strong function of the overlying waveguide, two waveguide materials have been investigated, which are polyimide and polystyrene. To determine the mass sensitivity of Love-wave sensor, bovine serum albumin (BSA) protein was injected into the Love-wave test cell while recording the magnitude and phase shift across each sensor. Polyimide had the lowest mass detection limit with an estimated value of 1.0-2.0 ng/cm2, as compared to polystyrene where D1 = 2.0 ng/cm2. Suitable chemistries were used to orient antibodies on the Love-wave sensor using protein G. The thickness of each biofilm was measured using ellipsometry from which the surface concentrations were calculated. The monoclonal antibody BD8 with a high degree of selectivity for anthrax spores was used to capture the non-pathogenic simulant B. thuringiensis B8 spores. Bacillus subtilis spores were used as a negative control to determine whether significant non-specific binding would occur. Spore aliquots were prepared using an optical counting method, which permitted removal of background particles for consistent sample preparation. This work demonstrates that Love-wave biosensors are promising for low-level detection for whole-cell biological pathogens.  相似文献   

14.
Nucleic acid amplification has long been used in biosensor technologies, such as DNA sensors, DNA chips and microarrays, due to its advantage of high sensitivity in detecting target DNA. However, dynamic monitoring of nucleic acid amplifications with traditional DNA sensors in real-time is difficult since a constant temperature must be maintained during detection. Thus, the piezoelectric sensor, one type of traditional DNA sensor, is not applicable in real-time monitoring PCR due to the dramatic change in temperature that occurs during reaction. In this study, we introduced strand displacement amplification (SDA), an well-developed nucleic acid amplification technique that can work under conditions of constant temperature, into the development of a novel piezoelectric sensor. Using the new SDA-piezoelectric DNA sensor, we designed a stable system for liquid-phase detection, in which the crystal oscillator plate was fixed by an easily adjustable screw-threaded clamping mechanism and successfully applied the new sensor system to real-time SDA monitoring of human cytomegalovirus (HCMV). This new technique overcomes the shortcomings of traditional DNA sensors in real-time monitoring of nucleic acid amplification. The technique has proved to be a markedly simplified procedure with a number of advantages, such as higher sensitivity, better time efficiency, and the ability of dynamic real-time detection.  相似文献   

15.
In this study, we investigated the activity, stability, lifetime and re-usability of monoclonal antibodies to myoglobin covalently immobilised onto microfabricated cantilever surfaces. These sensing surfaces are of interest to us in the development of novel cantilever-based immunosensors. For such sensors the antibody layer represents the sensing element while the microcantilever acts as a mechanical transducer. A procedure for producing re-usable biological coatings has been tested with different independent techniques. An Enzyme Linked Immunosorbent Assay (ELISA) was used to determine the presence of an active antibody coating, and to monitor the lifetime and stability of the immobilised antibody. Through this analysis, the activity of the immobilised antibody layer was found to be more stable with the introduction of sucrose, as a stabilising agent. Sucrose was applied to the immobilised antibody layer after each regeneration step. The immobilised antibody was found to have a stable active lifetime for up to 7 weeks. Fluorescence microscopy was used to give information on the distribution of the coating on the gold and silicon nitride sides of the cantilever. Atomic Force Microscopy was used to determine the presence of the biological coating on the cantilever and to obtain information on the surface morphology of the biological element of the sensor. The combined results provide valuable information on the development of an optimised sensing element and demonstrate a set of methods to use for future sensor-to-sensor characterisation. Preliminary experimental results showing the antibody activity against myoglobin, detected with a microcantilever based sensor prototype confirmed the motivations and potentialities of the proposed immunosensing technique.  相似文献   

16.
In this article, a phage-based magnetoelastic sensor for the detection of Salmonella typhimurium is reported. Filamentous bacteriophage specific to S. typhimurium was used as a biorecognition element in order to ensure specific and selective binding of bacteria onto the sensor surface. Phage was immobilized onto the surface of the sensors by physical adsorption. The phage immobilized magnetoelastic sensors were exposed to S. typhimurium cultures with different concentrations ranging from 5x10(1) to 5x10(8) cfu/ml, and the corresponding changes in resonance frequency response of the sensor were studied. It was experimentally established that the sensitivity of the magnetoelastic sensors was higher for sensors with smaller physical dimensions. An increase in sensitivity from 159 Hz/decade for a 2 mm sensor to 770 Hz/decade for a 1 mm sensor was observed. Scanning electron microscopy (SEM) analysis of previously assayed biosensors provided visual verification of frequency changes that were caused by S. typhimurium binding to phage immobilized on the sensor surface. The detection limit on the order of 10(3) cfu/ml was obtained for a sensor with dimensions 1x0.2x0.015 mm.  相似文献   

17.
Quartz crystal microbalance (QCM) sensors are widely used for determining liquid properties or probing interfacial processes. For some applications the sensitivity of the QCM sensors typically used (5–20 MHz) is limited compared with other biosensor methods. In this study ultrasensitive QCM sensors with resonant frequencies from 39 to 110 MHz for measurements in the liquid phase are presented. The fundamental sensor effect of a QCM is the decrease of the resonant frequency of an oscillating quartz crystal due to the binding of mass on a coated surface during the measurement. The sensitivity of QCM sensors increases strongly with an increasing resonant frequency and, therefore, with a decreasing thickness of the sensitive area. The new kind of ultrasensitive QCM sensors used in this study is based on chemically milled shear mode quartz crystals which are etched only in the center of the blank, forming a thin quartz membrane with a thick, mechanically stable outer ring. An immunoassay using a virus specific monoclonal antibody and a M13-Phage showed an increase in the signal to noise ratio by a factor of more than 6 for 56 MHz quartz crystals compared with standard 19 MHz quartz crystals, the detection limit was improved by a factor of 200. Probing of acoustic properties of glycerol/water mixtures resulted in an increase in sensitivity, which is in very good agreement with theory. Chemically milled QCM sensors strongly improve the sensitivity in biosensing and probing of acoustic properties and, therefore, offer interesting new application fields for QCM sensors.  相似文献   

18.
生化需氧量(Biochemical oxygen demand,BOD)微生物传感器是一种快速检测水样中有机污染物含量的设备,固定化微生物是其核心部件之一,对其稳定性、响应时间、使用寿命及实际应用范围等性能有着重要影响。生物膜式BOD传感器较其他类型的BOD微生物传感器具有结构简单、灵敏度高、响应时间短等优点,受到广泛的研究和应用。本文主要针对固定化微生物在生物膜式BOD传感器中的应用情况,概述较典型的微生物固定化方式的原理、特点及应用;总结几类应用较多或具有较好前景的载体材料,并讨论载体特性与传感器性能之间的关系;综述微生物在该领域的应用现状;简要介绍生物膜式BOD传感器的实际应用及商业化现状,比较其与另外几种BOD微生物传感器的优缺点;分析生物膜式BOD传感器中固定化微生物现存的一些问题及其发展趋势。  相似文献   

19.
A temperature sensor based on hollow fiber (HF) filled with graphene-Ag composite nanowire and liquid is presented. The coupling properties and sensing performance are numerically analyzed by finite element method using wavelength and amplitude interrogations. Results show that the sensor exhibiting strong birefringence with x-polarized peak provides much higher sensitivities and better signal-to-noise ratio (SNR) than y-polarized, which is more suitable for temperature detection. The graphene-Ag composite nanowire can not only solve the oxidation problem but also avoid the metal coating. Moreover, it provides better performance than other similar works like Au-Ag nanowire-filled, Au nanowire-filled, and Ag nanowire-filled sensors. Contrary to the blue shift of traditional SPR temperature sensors, the resonance peak shifts to the longer wavelength in our device when temperature increases and the high sensitivity 9.44 nm/ °C is obtained. The influences of nanowire diameter, grapheme-layer thickness on the designed sensor, are also investigated. This work can provide a reference for developing a high sensitivity, real-time, remote sensing, and distributed temperature SPR sensor.  相似文献   

20.
Rapid and sensitive biosensor for Salmonella   总被引:2,自引:0,他引:2  
The rapid and sensitive detection of Salmonella typhymurium based on the use of a polyclonal antibody immobilized by the Langmuir-Blodgett method on the surface of a quartz crystal acoustic wave device was demonstrated. The binding of bacteria to the surface changed the crystal resonance parameters; these were quantified by the output voltage of the sensor instrumentation. The sensor had a lower detection limit of a few hundred cells/ml, and a response time of < 100 s over the range of 10(2)-10(10) cells/ml. The sensor response was linear between bacterial concentrations of 10(2)-10(7) cells/ml, with a sensitivity of 18 mV/decade. The binding of bacteria was specific with two binding sites needed to bind a single cell. The sensors preserve approximately 75% of their sensitivity over a period of 32 days.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号