共查询到20条相似文献,搜索用时 15 毫秒
1.
Hyun Joo Shim Jong Jin Lee Sang Deuk Lee Won Bae Kim Junnick Yang So Hee Kim Myung Gull Lee 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1997,689(2):1131
A high-performance liquid chromatographic method was developed for the determination of a new non-narcotic analgesic, DA-5018 (I), in rat plasma, urine and bile samples, using propranolol for plasma samples and protriptyline for urine and bile samples as internal standards. The method involved extraction followed by injection of 100 μl of the aqueous layer onto a C18 reversed-phase column. The mobile phases were 5 mM methanesulfonic acid with 10 mM NaH2PO4 (pH 2.5)-acetonitrile, 70:30 (v/v) for plasma samples and 75:25 (v/v) for urine and bile samples. The flow-rates were 1.0 ml/min for plasma samples and 1.2 ml/min for urine and bile samples. The column effluent was monitored by a fluorescence detector with an excitation wavelength of 270 nm and an emission wavelength of 330 nm. The retention time for I was 4.8 min in plasma samples and 10.0 min in urine and bile samples. The detection limits for I in rat plasma, urine and bile were 20, 100 and 100 ng/ml, respectively. There was no interference from endogenous substances. 相似文献
2.
Kye Soo Han Hyun-Cheol Choi Joong-Keun Yoo Jong Wook Lee Myung Gull Lee 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1997,696(2):157
A high-performance liquid chromatographic method was developed for the determination of a new proton pump inhibitor, YH1885 (I), in human plasma and urine, and rat blood and tissue homogenate using fenticonazole as an internal standard. The sample preparation was simple: a 2.5 volume of acetonitrile was added to the biological sample to deproteinize it. A 50-μl aliquot of the supernatant was injected onto a C8 reversed-phase column. The mobile phase employed was methanol-0.005 M tetrabutylammonium dihydrogenphosphate (77:23, v/v), and it was run at a flow-rate of 1.0 ml/min. The column effluent was monitored using an ultraviolet detector at 270 nm. The retention times for I and the internal standard were 9.0 and 10.3 min, respectively. The detection limits for I in human plasma and urine, and in rat tissue homogenate (including blood) were 50, 100 and 100 ng/ml, respectively. The coefficients of variation of the assay (within-day and between-day) were generally low (below 8.84%) for human plasma and urine, and for rat tissue homogenate. No interferences from endogenous substances were found. 相似文献
3.
Elizabeth B. Agnew Richard H. Wilson Jean L. Grem Leonard Neckers Daoqin Bi Chris H. Takimoto 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2001,755(1-2)
A sensitive HPLC assay has been developed to determine the concentration of 17-(allylamino)-17-demethoxygeldanamycin (AAG) in human plasma over the concentration range of 12.5 to 2500 nM (7.33 to 1465 ng/mL). After the addition of 1000 nM geldanamycin as the internal standard, 1 mL samples of human plasma were subjected to solid-phase extraction, via Bond-Elut C18 cartridges, followed by analysis using an isocratic reversed-phase HPLC assay with UV detection. A Phenomenex Kingsorb, 3 micron, C18, 150×4.60 mm column and a Phenomenex Security Guard pre-column, C18 (ODS, Octadecyl), were used to achieve separation. AAG and GM were monitored at 334 and 308 nm, respectively, on a Hewlett-Packard 1050 Diode-Array Detector. The mobile phase, run at a flow-rate of 1 mL/min, was composed of 50% (v/v) 25 mM sodium phosphate (pH 3.00) with 10 mM triethylamine and 50% acetonitrile. HPLC effectively resolved AAG with retention times of 14.60
0.54 min and the internal standard geldanamycin at 10.72±0.38 min (n=15). This assay was able to measure plasma concentrations of AAG, the lower limit of quantitation being 12.5 nM, at a starting dose of 10 mg/m2 infused intravenously over 1 h in a Phase I clinical trial in adult patients with solid tumors. 相似文献
4.
A sensitive high-performance liquid chromatography method for the determination of taurine in human plasma was developed. Taurine and N-methyltaurine (internal standard) were derivatized with 4-(5,6-dimethoxy-2-phthalimidinyl)-2-methoxyphenylsulfonyl chloride to produce fluorescent sulfonamides. The labeling reaction was carried out at 70 degrees C for 20 min at pH 7.5. The fluorescent derivatives were separated on a reversed-phase column by a stepwise elution using (A) acidic phosphate buffer/acetonitrile (83/17) and (B) acetonitrile and detected by fluorescence measurement at excitation and emission wavelengths of 318 and 392 nm, respectively. The detection limit (signal-to-noise ratio=3) of taurine was 3 fmol per injection. The within-day and day-to-day relative standard deviations were 3.0-4.8 and 2.5-4.7%, respectively. The concentration (means) of taurine in normal human plasma was 48.9+/-7.5 microM. 相似文献
5.
Sun Hwa Lee Myung Gull Lee 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1994,656(2)
High-performance liquid chromatographic methods were developed for the determination of azosemide and its metabolite, M1, in human plasma and urine and rabbit blood and tissue homogenates. The methods involved deproteinization of the biological samples: 2.5 volumes of acetonitrile were used for the determination of azosemide and 1 volume of saturated Ba(OH)2 and ZnSO4 for that of M1. A 50-μl aliquot of the supernatant was injected onto a C18 reversed-phase column in each instance. The mobile phases employed were 0.03 M phosphoric acid—acetonitrile (50:40, v/v) for azosemide and 0.03 M phosphoric acid/0.2 M acetic acid—acetonitrile (83:17, v/v) for M1. The flow-rate was 1.5 ml/min in both instances. The column effluent was monitored by ultraviolet detection at 240 and 236 nm for azosemide and M1, respectively. The retention times for azosemide and M1 were 6.0 and 8.3 min, respectively. The detection limits for both azosemide and M1 in both human plasma and urine were 50 ng/ml. The coefficients of variation of the assay were generally low (below 11.0%) for plasma, urine, blood and tissue homogenates. No interferences from endogenous substances or other diuretics tested were observed. 相似文献
6.
T. S. Selvamuniandy N. Mohamed S. M. Mansor N. K. Nair V. Navaratnam 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1997,700(1-2):209-213
A selective and sensitive HPLC assay for the quantitative determination of a new antifilarial drug, 6,4′-bis-(2-imidazolinylhydrazone)-2-phenylimidazo[1,2-a]pyridine (CDR 101) is described. After extraction from plasma and blood, CDR 101 was analysed using a C18 Nucleosil ODS column (250×4.6 mm, 5 μm particle size) and mobile phase of acetonitrile-0.05 M ammonium acetate adjusted to pH 3.0, with UV detection at 318 nm. The mean recoveries of CDR 101 in plasma and blood over a concentration range of 25–500 ng/ml were 95.5±2.01% and 83.3±1.87%, respectively. The within-day and day-to-day coefficient of variations for plasma were 3.23-6.21% and 2.59-9.90%, respectively, those for blood were 2.59-5.92% and 2.89-6.82%, respectively. The minimum detectable concentration for CDR 101 was 1 ng/ml in plasma and 2.5 ng/ml in whole blood. This method was found to be suitable for clinical pharmacokinetic studies. 相似文献
7.
Teh Lo Lee Marvin A. Brooks J.Arthur F. de Silva 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1981,224(2):275-288
A rapid, sensitive and specific normal-phase (adsorption) high-performance liquid chromatographic (HPLC) assay was developed for the determination of 1-(2-aminoethyl)-3-(2,6-dichlorophenyl)thiourea [I] in plasma and urine. The assay involves the extraction of the compound into methylene chloride from plasma or urine buffered to pH 10, and the HPLC analysis of the residue dissolved in methylene chloride—methanol—heptane (85:10:5). A 10-μm silica gel column was used with methylene chloride—methanol—heptane—ammonium hydroxide (85:10:5:0.1) as the eluting solvent. The effluent was monitored at 254 nm and quantitation was based on the peak height vs. concentration technique. The assay has a recovery of 64.5 ± 4.5% (S.D.) from plasma and 96.0 ± 6.3% (S.D.) from urine in the concentration range of 0.1–2 μg per ml and 2–40 μg per 0.1 ml of plasma and urine, respectively, with a limit of detection of 0.05–0.1 μg [I] per ml of plasma using a 1-ml specimen and 0.1 μg per ml urine using a 0.1-ml specimen, respectively. The assay was applied to the determination of plasma levels and urinary excretion of the compound [I] in dog following the oral administration of 28.8 mg of [I] · maleate per kg body weight.The HPLC assay was also used to determine the stability of [I] and for the measurement of a potential degradation product, clonidine [II] [2-(2,6-dichlorophenylamino)-2-imidazoline] in pooled human plasma stored at ?17°C, and pooled human urine stored at ?17°C and ?90°C, respectively. 相似文献
8.
2-(Phenoxy)propionate derivatives were separated on three chiral columns, OD, OK, and chiral-2 columns. The chlorine substitution in the phenyl ring and the alcohol moiety of the ester groups of the derivatives had great influence for separation on the OD and OK columns, but little effect on the chiral-2 column. 相似文献
9.
Jan Olgemller Georg Hempel Joachim Boos Gottfried Blaschke 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1999,726(1-2)
(E)-5-(2-Bromovinyl)-2′-deoxyuridine is an antiviral drug used for treatment of infections with Herpes simplex virus type 1 as well as Varicella zoster virus. Two fast methods for the determination of the drug and its metabolite in plasma and urine by capillary electrophoresis have been developed. The plasma method can be used for measurement of total as well as unbound drug and metabolite. Plasma and urine samples are prepared for measuring by liquid/liquid extraction resulting in a limit of quantification of 40 ng/ml for total and 10 ng/ml for free BVdU in plasma and 170 ng/ml in urine. Inter- as well as intra-day precision were found to be better than 10% and both methods have been used for drug monitoring of patients. 相似文献
10.
Margareta Bielenstein Leif Astner Staffan Ekberg 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1999,730(2):671-182
The chemical substance 2-(2-nitro-4-trifluoromethylbenzoyl)-1,3-cyclohexanedione (NTBC) is in clinical use for the treatment of hereditary tyrosinemia type 1. In the present study, the plasma concentration of NTBC was determined by a coupled column liquid chromatographic method. A 20-μl volume of plasma was diluted with phosphate buffer, pH 2, and injected into a small precolumn (BioTrapAcid C18) with a mobile phase containing sulfuric acid. The precolumn was based on the restricted access principle, i.e., retention of NTBC within the lipophilic pores, while polar and large endogenous compounds were eluted with the void volume. NTBC was transferred to the analytical column using a mobile phase with a high content of acetonitrile. The compound was monitored by UV detection at 278 nm. The standard curve was linear between 0.3 and 69 μM, and the between-day precision (RSD) was 3% (n=6 days) at 13.8 μM and 14% (n=6 days) at 0.3 μM NTBC in plasma. The quantitation limit was approximately 0.3 μM using 20 μl of plasma. 相似文献
11.
Hirofumi Inoue Haruo Iguchi Akira Kono Yasuto Tsuruta 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1999,724(2):689
A highly sensitive pre-column HPLC method for simultaneous determination of prolyl dipeptides, Pro and Hyp in urine was developed. The analytes were labelled with 4-(5,6-dimethoxy-2-phthalimidinyl)-2-methoxyphenylsulfonyl chloride at 70°C for 20 min. The derivatives separated on tandem reversed-phase columns by a gradient elution and were monitored with fluorescence detection at 318 nm (excitation) and 392 nm (emission). The detection limits for prolyl dipeptides, Pro and Hyp were 1–5 fmol/injection (S/N=3). Urine samples were treated with o-phthalaldehyde, followed by purification on a Bond Elut C18 column before conducting the labelling reaction. Pro–Hyp, Pro–Gly and Pro–Pro were identified as prolyl dipeptides in urine. The within-day and between-day relative standard deviations were 1.5–4.8 and 1.7–5.8%, respectively. The concentrations of Pro–Hyp, Pro–Gly, Pro–Pro, Pro and Hyp in normal human urine were 97.6±28.2, 2.74±1.48, 2.08±1.13, 6.71±3.34 and 2.30±1.59 nmol/mg creatinine, respectively. 相似文献
12.
We have developed a simple and highly sensitive semimicro high-performance liquid chromatographic method for the simultaneous determination of free and N-acetylated polyamines in urine. Polyamines and N-acetylated polyamines were derivatized with 4-(5,6-dimethoxy-2-phthalimidinyl)-2-methoxyphenylsulfonyl chloride to produce fluorescent sulfonamides. The labeling reaction was carried out at 50 degrees C for 15 min at pH 9. The fluorescent derivatives were separated on a reversed-phase column with a gradient elution using water-acetonitrile-methanol at 50 degrees C and detected by fluorescence measurement at 318 nm (excitation) and 406 nm (emission). The detection limits (signal-to-noise ratio=3) of the polyamines and N-acetylated polyamines were 0.7-4.5 fmol/injection. The within-day and day-to-day relative standard deviations were 3.2-7.9 and 3.0-7.7%, respectively. Significant differences were found in the urinary excretion of polyamines between cancer patients and normal subjects. 相似文献
13.
H. S. Bonner L. M. Shaw 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2000,739(2)
A high-performance liquid chromatographic method for automated analysis of both protein-bound and total S-2-(3-aminopropylamino)ethanethiol (WR-1065) in blood has been developed in our laboratory. WR-1065 is the active thiol metabolite of the radio- and chemo-protector drug amifostine (WR-2721). Using WR-1065 quality control levels over the experimental range: 7.0, 45.0 and 85.0 μmol/l spiked into plasma, method validation for total WR-1065 included between-run assessment of imprecision (SD/C.V.%: 1.11/16.7%, 6.58/15.5% and 9.24/11.3%, respectively) and % accuracy (94.7, 106.0 and 97.2%). 相似文献
14.
Martin R. Hackman Teh Lo lee Marvin A. Brooks 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1983,273(2):347-356
A rapid, sensitive and selective high-performance liquid chromatographic (HPLC) assay was developed for the determination of cibenzoline (Cipralan TM) in human plasma and urine. The assay involves the extraction of the compound into benzene from plasma or urine buffered to pH 11 and HPLC analysis of the residue dissolved in acetonitrile---phosphate buffer (0.015 mol/1, pH 6.0) (80:20). A 10-μ ion-exchange (sulfonate) column was used with acetonitrile—phosphate buffer (0.015 mol/1, pH 6.0) (80:20) as the mobile phase. UV detection at 214 nm was used for quantitation with the di-p-methyl analogue of cibenzoline as the internal standard.The recovery of cibenzoline in the assay ranged from 60 to 70% and was validated in human plasma and urine in the concentration range of 10–1000 ng/ml and 50–5000 ng/ml, respectively. A normal-phase HPLC assay was developed for the determination of the imidazole metabolite of cibenzoline. The assays were applied to the determination of plasma and urine concentrations of cibenzoline and trace amounts of its imidazole metabolite following oral administration of cibenzoline succinate to two human subjects. 相似文献
15.
Kenneth O. Ebete John E. Koundourellis 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1996,677(2):319-323
A rapid, reliable and specific reversed-phase high-performance liquid chromatographic procedure is described for the determination of diphenylpyraline hydrochloride at nanogram concentrations in plasma and urine. After extraction of the drug with n-pentane-2-propanol (50:1) from alkalinized samples, the organic extract was evaporated to dryness, reconstituted with methanol and chromatographed using a 5-μm Asahipak ODP-50 C18 column with UV detection at 254 nm. The elution time for diphenylpyraline was 7.9 min. The overall recovery of diphenylpyraline from spiked plasma and urine samples at concentrations ranging from 53 to 740 ng/ml were 94.65% and 92.29%, respectively. Linearity and precision data for plasma and urine standards after extraction were acceptable. The limit of detection was 15 ng/ml for both plasma and urine samples at 0.002 AUFS. 相似文献
16.
17.
Teh Lo Lee Marvin A. Brooks 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1982,227(1):137-148
A rapid, sensitive and specific high-performance liquid chromatographic (HPLC) assay was developed for the determination of amdinocillin (formerly mecillinam) in human plasma and urine. The assay is performed by direct injection of a plasma protein-free supernatant or a dilution of urine. A 10-μm μBondapak phenyl column with an eluting solvent of water—methanol—1 M phosphate buffer, pH 7 (70:30:0.5) was used, with UV detection of the effluent at 220 nm. Azidocillin potassium salt [potassium-6-(d-(-)-α-azidophenyacetamido)-penicillanate] was used as the internal standard and quantitation was based on peak height ratio of amdinocillin to that of the internal standard. The assay has a recovery of 74.4 ± 6.3% (S.D.) in the concentration ranges of 0.1–20 μg per 0.2 ml of plasma with a limit of detection equivalent to 0.5 μg/ml plasma. The urine assay was validated over a concentration range of 0.025–5 mg/ml of urine, and has a limit of detection of 0.025 mg/ml (25 μg/ml) using a 0.1-ml urine specimen per assay.The assay was applied to the determination of plasma and urine concentrations of amdinocillin following intravenous administration of a 10 mg/kg dose of amdinocillin to two human subjects. The HPLC and microbiological assays were shown to correlate well for these samples. 相似文献
18.
19.
J.G. Supko L.R. Phillips L. Malspeis 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1996,677(2):351
A facile, sensitive and highly specific HPLC method for assaying 1-(2-chloroethyl)-3-sarcosinamide-1-nitrosourea (SarCNU) in plasma has been developed. The drug was efficiently isolated from plasma by extraction with tert.-butyl methyl ether. A structurally related compound with similar physicochemical properties served as the internal standard (I.S.). Following evaporation of the organic solvent, the extract was reconstituted with 0.05 M ammonium acetate buffer, pH 5.0, and loaded onto a 4 μm Nova-Pak C18 column (15 cm×3.9 mm), which was preceded by a 7 μm Brownlee RP-18 precolumn (1.5 cm×3.2 mm). Chromatography was performed at ambient temperature using a mobile phase of methanol-0.1 M ammonium formate buffer, pH 3.7 (25:75, v/v). UV absorbance of the effluent was monitored at 240 nm. A flow-rate of 1.0 ml/min was used for analyzing mouse and dog plasma extracts. Under these conditions, the drug eluted at 4.0 min and was followed by the I.S. at 6.1 min. An automatic switching valve was employed to allow the precolumn to be flushed 1.5 min into the run, without interrupting the flow of the mobile phase to the analytical column, thereby preventing the apparent build-up of extractable, strongly retained, UV-absorbing components present in mouse and dog plasma. Operating in this manner, more than 100 samples could be analyzed during a day using a refrigerated autosampler for overnight injection. The method was readily adapted to the determination of SarCNU in human plasma by simply decreasing the eluent flow-rate to 0.6 ml/min, whereby SarCNU and the I.S. eluted at approximately 5.8 and 9.1 min, respectively. Furthermore, the switching valve was not necessary for the analysis of human plasma samples. With a 50-μl sample volume, the lowest concentration of SarCNU included in the plasma standard curves, 0.10 μg/ml, was quantified with a 7.8% R.S.D. (n=27) over a 2 month period. Plasma standards, with concentrations of 0.26 to 5.1 μg/ml, exhibited R.S.D. values ranging from 1.3 to 4.7%. Thermospray-ionization MS detection was used to definitively establish the specificity of the method. The sensitivity of the assay was shown by application to be more than adequate for characterizing the plasma pharmacokinetics of SarCNU in mice. 相似文献
20.
Takashi Kawauchi Hiroshi Matsumoto Shingo Yano 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2001,751(2):325-330
A high-performance liquid chromatographic method for the determination of a new thymidine phosphorylase inhibitor, TPI, in dog and rat plasma is described. TPI was isolated from biological samples by solid-phase extraction on Bond Elut PRS columns. Chromatographic separation was achieved on a C18 column using a mobile phase consisting of acetonitrile–10 mM acetate buffer (pH 4.3) including hexanesulfonate, with UV detection at 276 nm. This method has been validated across the range of 50–50 000 ng/ml using a 0.1-ml plasma volume. The mean recoveries from spiked plasma were 93% for dog and 94% for rat, respectively. The accuracy, precision and specificity of the method were demonstrated to be acceptable, and it was applied to the toxicokinetic study of TPI in rats. 相似文献