首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The purposes of this study were (a) to determine whether a significant strength imbalance existed between the left and right or dominant (D) and nondominant (ND) legs and (b) to investigate possible correlations among various unilateral and bilateral closed kinetic chain tests, including a field test, and traditional isokinetic dynamometry used to determine strength imbalance. Fourteen Division I collegiate women softball players (20.2 +/- 1.4 years) volunteered to undergo measures of average peak torque for isokinetic flexion and extension at 60 degrees .s(-1) and 240 degrees .s(-1); in addition, measures of peak and average force of each leg during parallel back squat, 2-legged vertical jump, and single-leg vertical jump and performance in a 5-hop test were examined. Significant differences of between 4.2% and 16.0% were evident for all measures except for average force during single-leg vertical jump between the D and ND limbs, thus revealing a significant strength imbalance. The 5-hop test revealed a significant difference between D and ND limbs and showed a moderate correlation with more sophisticated laboratory tests, suggesting a potential use as a field test for the identification of strength imbalance. The results of this study indicate that a significant strength imbalance can exist even in collegiate level athletes, and future research should be conducted to determine how detrimental these imbalances could be in terms of peak performance for athletes, as well as the implications for injury risk.  相似文献   

2.
A phenomenological model for muscle energy consumption was developed and used in conjunction with a simple Hill-type model for muscle contraction. The model was used to address two questions. First, can an empirical model of muscle energetics accurately represent the total energetic behavior of frog muscle in isometric, isotonic, and isokinetic contractions? And second, how does such a model perform in a large-scale, multiple-muscle model of human walking? Four simulations were conducted with frog sartorius muscle under full excitation: an isometric contraction, a set of isotonic contractions with the muscle shortening a constant distance under various applied loads, a set of isotonic contractions with the muscle shortening over various distances under a constant load, and an isokinetic contraction in lengthening. The model calculations were evaluated against results of similar thermal in vitro experiments performed on frog sartorius muscle. The energetics model was then incorporated into a large-scale, multiple-muscle model of the human body for the purpose of predicting energy consumption during normal walking. The total energy estimated by the model accurately reflected the observed experimental behavior of frog muscle for an isometric contraction. The model also accurately reproduced the experimental behavior of frog muscle heat production under isotonic shortening and isokinetic lengthening conditions. The estimated rate of metabolic energy consumption for walking was 29% higher than the value typically obtained from gait measurements.  相似文献   

3.
The aim of this study was to investigate the differences in the length-dependent changes in quadriceps muscle torque during voluntary isometric and isokinetic contractions performed after severe muscle-damaging exercise. Thirteen physically active men (age = 23.8 ± 3.2 years, body weight = 77.2 ± 4.5 kg) performed stretch-shortening cycle (SSC) exercise comprising 100 drop jumps with 30-second intervals between each jump. Changes in the voluntary and electrically evoked torque in concentric and isometric conditions at different muscle lengths, muscle soreness, and plasma creatine kinase (CK) activity were assessed within 72 hours after SSC exercise. Isokinetic knee extension torque decreased significantly (p < 0.05) at all joint angles after SSC exercise. At 2 minutes and at 72 hours after SSC exercise, the changes in knee torque were significantly smaller at 80° (where 180° = full knee extension) than at 110-130°. At 2 minutes after SSC exercise, the optimal angle for isokinetic knee extension torque shifted by 9.5 ± 8.9° to a longer muscle length (p < 0.05). Electrically induced torque at low-frequency (20-Hz) stimulation decreased significantly more at a knee joint angle of 130° than at 90°. The subjects felt acute muscle pain and CK activity in the blood increased to 1,593.9 ± 536.2 IU·L?1 within 72 hours after SSC exercise (p < 0.05). This study demonstrates that the effect of muscle-damaging exercise on isokinetic torque is greatest for contractions at short muscle lengths. These findings have practical importance because the movements in most physical activities are dynamic in nature, and the decrease in torque at various points in the range of motion during exercise might affect overall performance.  相似文献   

4.
Despite numerous reports on isometric force depression, few reports have quantified force depression during active muscle shortening (dynamic force depression). The purpose of this investigation was to determine the influence of shortening history on isometric force following active shortening, force during isokinetic shortening, and velocity during isotonic shortening. The soleus muscles of four cats were subjected to a series of isokinetic contractions at three shortening velocities and isotonic contractions under three loads. Muscle excursions initiated from three different muscle lengths but terminated at a constant length. Isometric force produced subsequent to active shortening, and force or shortening velocity produced at a specific muscle length during shortening, were compared across all three conditions. Results indicated that shortening history altered isometric force by up to 5%, force during isokinetic shortening up to 30% and shortening velocity during isotonic contractions by up to 63%. Furthermore, there was a load by excursion interaction during isotonic contractions such that excursion had the most influence on shortening velocity when the loads were the greatest. There was not a velocity by excursion interaction during isokinetic contractions. Isokinetic and isotonic power–velocity relationships displayed a downward shift in power as excursions increased. Thus, to discuss force depression based on differences in isometric force subsequent to active shortening may underestimate its importance during dynamic contractions. The presence of dynamic force depression should be realized in sport performance, motor control modeling and when controlling paralyzed limbs through artificial stimulation.  相似文献   

5.
For static and dynamic conditions muscle geometry of the musculus gastrocnemius medialis of the rat was compared at different muscle lengths. The dynamic conditions differed with respect to isokinetic shortening velocity (25, 50 and 75 mm/s) of the muscle-tendon complex and in constancy of force (isotonic) and velocity (isokinetic) during shortening. Muscle geometry was characterized by fibre length and angle as well as aponeurosis length and angle. At high isokinetic shortening velocities (50 and 75 mm/s) small differences in geometry were found with respect to isometric conditions: aponeurosis lengths differed maximally by -2%, fibre length only showed a significant increase (+3.2%) at the highest shortening velocity. The isotonic condition only yielded significant differences of fibre angle (-4.5%) in comparison with isometric conditions. No significant differences of muscle geometry were found when comparing isotonic with isokinetic conditions of similar shortening velocity. The small differences of geometry between isometric and dynamic conditions are presumably due to the lower muscle force in the dynamic condition and the elastic behaviour of the aponeurosis. It is concluded that, unless very high velocities of shortening are used, the relationship between muscle geometry and muscle length in the isometric condition may be used to describe muscle geometry in the dynamic condition.  相似文献   

6.
The aim of this article is to present data on the strength and power characteristics of forwards and backs in a squad of elite English rugby league players and compare these findings to previously published literature from Australia. Participants were elite English rugby league players (n = 18; height 184.16 ± 5.76 cm; body mass 96.87 ± 10.92 kg, age 21.67 ± 4.10 years) who were all regular first team players for an English Superleague club. Testing included 5-, 10-, 20-m sprint times, agility, vertical jump, 40-kg squat jump, isometric squat, concentric and eccentric isokinetic knee flexion and extension. Independent t-tests were performed to compare results between forwards and backs, with paired samples t-tests used to compare bilateral differences from isokinetic assessments and agility tests. Forwards demonstrated significantly (p < 0.05) greater body mass (102.15 ± 7.5 kg), height (186.30 ± 5.47 cm), power during the 40-kg jump squat (2,106 ± 421 W), isometric force (3,122 ± 611 N) and peak torque during left concentric isokinetic knee extension (296.1 ± 54.2 N·m) compared to the backs (86.30 ± 8.97 kg; 179.87 ± 3.72 cm; 1,709 ± 286 W; 2,927 ± 607 N; 241.7 ± 35.2 N·m, respectively). However, no significant differences (p > 0.05) were noted between forwards and backs during right concentric isokinetic knee extension (274.8 ± 37.7 and 246.8 ± 25.8 N·m), concentric isokinetic knee flexion for both left (158.8 ± 28.6 and 141.0 ± 22. 7 N·m) and right legs (155.3 ± 22.9 and 128.0 ± 23.9 N·m), eccentric isokinetic knee flexion and extension, hamstring quadriceps ratios, or vertical jump (37.25 ± 4.35 and 40.33 ± 6.38 cm). In comparison, relative measures demonstrated that backs performed significantly better compared to the forwards during the 40-kg jump squat (20.71 ± 5.15 and 19.91 ± 3.91 W·kg?1) and the isometric squat (34.32 ± 7.9 and 30.65 ± 5.34 N·kg?1). Bilateral comparisons revealed no significant differences (p > 0.05) between left and right leg performances in the agility test (3.26 ± 0.18 and 3.24 ± 0.18 seconds), or between left (0.7 ± 0.10) and right (0.71 ± 0.17) leg eccentric hamstring concentric quadriceps ratios. The results demonstrate that absolute strength and power measures are generally higher in forwards compared to in backs; however, when body mass is taken into account and relative measures compared, the backs outperform the forwards.  相似文献   

7.
The purpose of this investigation was to determine the mechanomyographic (MMG) amplitude and mean power frequency (MPF) versus torque (or force) relationships during isokinetic and isometric muscle actions of the biceps brachii. Ten adults (mean +/- SD age = 21.6 +/- 1.7 years) performed submaximal to maximal isokinetic and isometric muscle actions of the dominant forearm flexors. Following determination of isokinetic peak torque (PT) and the isometric maximum voluntary contraction (MVC), the subjects randomly performed submaximal step muscle actions in 10% increments from 10% to 90% PT and MVC. Polynomial regression analyses indicated that MMG amplitude increased linearly with torque during both the isokinetic (r2 = 0.982) and isometric (r2 = 0.956) muscle actions. From 80% to 100% of isometric MVC, however, MMG amplitude appeared to plateau. Cubic models provided the best fit for the MMG MPF versus isokinetic (R2 = 0.786) and isometric (R2 = 0.940) torque relationships, although no significant increase in MMG MPF was found from 10% to 100% of isokinetic PT. For the isometric muscle actions, however, MMG MPF remained relatively stable from 10% to 50% MVC, increased from 50% to 80% MVC, and decreased from 80% to 100% MVC. The results demonstrated differences in the MMG amplitude and MPF versus torque relationships between the isokinetic and isometric muscle actions. These findings suggested that the time and frequency domains of the MMG signal may be useful for describing the unique motor control strategies that modulate dynamic versus isometric torque production.  相似文献   

8.
The aim of this study was to test the hypothesis that the repeated bout effect depends on intraindividual variability during a second bout of eccentric exercise. Eleven healthy men performed 2 resistance training bouts consisting of maximal eccentric exercise (EE1 and EE2) using the knee extensor muscles. The interval between the exercise bouts was 2 weeks and consisted of 10 sets of 12 repetitions at 160° · s(-1). Maximal isokinetic concentric torque at 30° · s(-1) was measured before the bouts and 2 minutes and 24 hours thereafter. Muscle soreness score and creatine kinase activity were determined before and after exercise. Intraindividual variability in torque during each eccentric repetition was measured during exercise. Repeated bout effect manifested after EE2: Muscle soreness was less, the shift in optimal knee joint angle to a longer muscle length was less, and the decrease in isokinetic concentric torque 2 minutes after exercise was less for EE2 compared with that for EE1. During concentric (isokinetic) contraction, length-dependent changes in isokinetic torque (IT) occurred after both EE1 and EE2: The shorter the muscle length, the greater the change in IT. There was a significant relationship between the decrease in maximal isokinetic knee extension torque 24 hours after EE1 and intraindividual variability of EE1 (R2 = 0.71, p < 0.05), but this relationship was not significant for EE2 (R2 = 0.18). It seems that intraindividual variability during eccentric exercise protects against muscle fatigue and damage during the first exercise bout but not during a repeat bout. These findings may be useful to coaches who wish to improve muscle function in resistance training with less depression in muscle function and discomfort of their athletes, specifically, when muscle is most sensitive to muscle-damaging exercise.  相似文献   

9.
The purpose of this study was to investigate the relationships between peripheral muscle structure (mass) and function (strength, endurance, and maximal aerobic capacity) in patients with chronic obstructive pulmonary disease (COPD) with different nutritional states. Thirty-nine patients (31 male) with moderate-severe COPD (63.5 ± 7.3 [SD] years) and 17 controls (14 male; 64.7 ± 5.5 [SD] years) underwent isokinetic (peak torque [PT]), isometric (isometric torque [IT]), and endurance strength (total work [TW]) measurements of the knee extensor muscles and a maximal cardiopulmonary exercise test to evaluate the maximal aerobic capacity (peak oxygen uptake [VO(2)] peak). Muscle mass (MM) was determined using dual-energy x-ray absorptiometry. Patients with COPD presented with reduced muscle function as compared with the healthy controls: PT (105.9 ± 33.9 vs. 134.3 ± 30.9, N·m(-1), respectively, p < 0.05), TW (1,446.3 ± 550.8 vs. 1,792.9 ± 469.1 kJ, respectively, p < 0.05), and VO(2)peak (68.1 ± 15.1 vs. 93.7 ± 14.5, % pred, respectively, p < 0.05). Significant relationships were found between muscle structure and function (strength and endurance) in the patient subgroup with preserved MM and in the control group: PT·MM(r(2) = 0.36; p = 0.01 vs. r(2) = 0.32; p = 0.01, respectively) and TW·MM (r(2) = 0.32; p = 0.01 vs. r(2) = 0.22; p = 0.05, respectively). Strength corrected for mass normalized this function in both patient subgroups, whereas endurance was normalized only in the patient subgroup without muscle depletion. Maximal aerobic capacity remained reduced, despite the correction, in both patient subgroups (depleted or nondepleted) compared with the healthy controls (VO(2)peak.MM: 9.1 ± 3.7 vs. 21.8 ± 4.9 vs. 28.5 ± 4.2 ml·min·kg, respectively, with p < 0.01 among groups). Muscle atrophy seems to be the main determinant of strength reduction among patients with moderate-severe COPD, whereas endurance reduction seems to be more related to imbalance between oxygen delivery and consumption than to the local muscle structure itself. Peripheral MM did not constitute a good predictor for maximal aerobic capacity in this population. The main practical application of this study is to point out a crucial role for the strategies able to ameliorate cardiorespiratory and muscular fitness in patients with COPD, even in those patients with preserved MM.  相似文献   

10.
This study assessed the mechanical reliability and validity of the INRTEK iSAM 9000 isokinetic dynamometer, and compared the obtained torque values of the prototype device with those from a traditional device. Sixty volunteers (40 men and 20 women) were tested at 60 degrees per second for shoulder, knee, and trunk flexion, and extension on both the Cybex 6000 and a new isokinetic dynamometer (iSAM 9000). Intraclass correlation coefficients (ICC) and standard errors of measurement (SEM) revealed a high level of reproducibility and precision in the device's torque measurements (ICC range = 0.94-0.98; SEM range = 5.2-29.7). Pearson r values revealed very high relationships between the two instruments (set 1: r = 0.84-0.93; set 2: r = 0.87-0.93; P < 0.05). Significantly higher peak torque for both sets of left and right knee flexion and extension, right shoulder extension and trunk extension was found for the iSAM 9000 compared to the Cybex 6000 (P < 0.05). The strong ICCs and small SEMs support the device's mechanical reliability and validity. The high correlation coefficients between the prototype dynamometer and the Cybex 6000 support the new device's validity in the measurement of isokinetic torque. The findings of this study will be used to refine the next generation of the INRTEK isokinetic device with respect to test protocols and the reliability of measuring human muscle performance.  相似文献   

11.
For decades it was believed that direct and indirect heating (the latter of which elevates blood and core temperatures without directly heating the area being evaluated) increases skin but not skeletal muscle blood flow. Recent results, however, suggest that passive heating of the leg may increase muscle blood flow. Using the technique of positron-emission tomography, the present study tested the hypothesis that both direct and indirect heating increases muscle blood flow. Calf muscle and skin blood flows were evaluated from eight subjects during normothermic baseline, during local heating of the right calf [only the right calf was exposed to the heating source (water-perfused suit)], and during indirect whole body heat stress in which the left calf was not exposed to the heating source. Local heating increased intramuscular temperature of the right calf from 33.4 ± 1.0°C to 37.4 ± 0.8°C, without changing intestinal temperature. This stimulus increased muscle blood flow from 1.4 ± 0.5 to 2.3 ± 1.2 ml·100 g?1·min?1 (P < 0.05), whereas skin blood flow under the heating source increased from 0.7 ± 0.3 to 5.5 ± 1.5 ml·100 g?1·min?1 (P < 0.01). While whole body heat stress increased intestinal temperature by ~1°C, muscle blood flow in the calf that was not directly exposed to the water-perfused suit (i.e., indirect heating) did not increase during the whole body heat stress (normothermia: 1.6 ± 0.5 ml·100 g?1·min?1; heat stress: 1.7 ± 0.3 ml·100 g?1·min?1; P = 0.87). Whole body heating, however, reflexively increased calf skin blood flow (to 4.0 ± 1.5 ml·100 g?1·min?1) in the area not exposed to the water-perfused suit. These data show that local, but not indirect, heating increases calf skeletal muscle blood flow in humans. These results have important implications toward the reconsideration of previously accepted blood flow distribution during whole body heat stress.  相似文献   

12.
A fast (0.1 mm steps within 2 ms), strong (40 N continuously) and accurate (resolution 0.002 N and 1.0 micron) muscle ergometer was developed to test dynamic and static properties of mammalian muscle. Both for twitches and for tetani isometric, isokinetic and isotonic contractions can be measured accurately. Force-velocity data and time to peak-force data of four EDL muscles, as well as force-extension data of their serial tendinous structures are shown to demonstrate the machine.  相似文献   

13.
The purpose of this study was to compare a piezoelectric contact sensor with an accelerometer for measuring the mechanomyographic (MMG) signal from the biceps brachii during submaximal to maximal isokinetic and isometric forearm flexion muscle actions. Following determination of isokinetic peak torque (PT) and the isometric maximum voluntary contraction (MVC), 10 adults (mean+/-SD age=22.8+/-2.7yrs) performed randomly ordered, submaximal step muscle actions of the dominant forearm flexors in 20% increments from 20% to 80% PT and MVC. Surface MMG signals were recorded simultaneously from a contact sensor and an accelerometer placed over the belly of the biceps brachii muscle. During the isokinetic and isometric muscle actions, the contact sensor and accelerometer resulted in linear increases in normalized MMG amplitude with torque (r(2) range=0.84-0.97) but the linear slope of the normalized MMG amplitude versus isokinetic torque relationship for the accelerometer was less (p<0.10) than that of the contact sensor. There was no significant (p>0.05) relationship for normalized MMG mean power frequency (MPF, %max) versus isokinetic and isometric torque for the contact sensor, but the accelerometer demonstrated a quadratic (R(2)=0.94) or linear (r(2)=0.83) relationship for the isokinetic and isometric muscle actions, respectively. There were also a number of significant (p<0.05) mean differences between the contact sensor and accelerometer for normalized MMG amplitude or MPF values. These findings indicated that in some cases involving dynamic and isometric muscle actions, the contact sensor and accelerometer resulted in different torque-related responses that may affect the interpretation of the motor control strategies involved.  相似文献   

14.
This study aimed to examine the relationship between the ratio of the length of the second and fourth digits (2D:4D) and locomotor muscle strength. Furthermore, two putative mechanisms that might explain any relationship of 2D:4D with muscle strength, specifically serum total and free testosterone, and androgen receptor genotype CAG repeat number (AR CAGn) were investigated. Seventy-seven healthy young Caucasian men completed a thorough assessment of isometric and isokinetic knee extensor strength, with unilateral measurements averaged across both legs and repeated on two occasions. The lengths of the second and fourth fingers of each hand were measured to calculate 2D:4D ratio. Serum total testosterone (TT) and serum hormone binding globulin (SHBG) were measured by ELISA and used to calculate free testosterone (FT). AR CAGn was determined by PCR and microchip electrophoresis. There was no association between mean, left or right hand 2D:4D and isometric or isokinetic knee extensor strength (all, R < 0.12, P > 0.32). TT and FT were unrelated to mean, left or right hand 2D:4D ratio (all, R < 0.12, P > 0.34). Finally AR CAGn was not associated with mean, right or left hand 2D:4D ratio (all, R < 0.20, P > 0.10). This study found no evidence of 2D:4D being related to locomotor muscle strength, TT, FT, or AR CAGn. The reported association of 2D:4D with sports performance does not seem to be explained by an influence on locomotor muscle strength, and could be due to an effect on motor or cognitive skills.  相似文献   

15.
The purpose of the present study was to investigate oarside and nonoarside lower extremity asymmetries in isokinetic strength and joint mobility of port and starboard oarsmen. Peak torques of right and left extensors and flexors were measured on isokinetic dynamometer at angular velocities of 60 and 180°·s-1 in 12 starboard (n = 12; training age 5.55 ± 0.52 years) and 14 port (n = 14; training age 6.09 ± 0.95 years) well-trained male rowers. Mobility of the hip, knee, and ankle joints was measured using the Myrin flexometer, a modification of the Leighton flexometer. The findings indicate that ports had a significantly higher peak torque in oarside right knee extensors at 60°·s-1 (p < 0.001) and 180°·s-1 (p < 0.01) compared to in the nonoarside left knee extensors. In a respective manner, starboards had a higher peak torque in left knee extensors at 60°·s-1 (p < 0.05) and 180°·s-1 (p < 0.05) compared to the right side. Right flexors peak torque was significantly higher in ports compared to that in starboards at 60°·s-1 (p < 0.05) and 180°·s-1 (p < 0.01). No significant difference between port and starboards in left knee flexors at either angular velocity was found. Both port and starboards exhibited a significantly higher hip (p < 0.01) mobility in oarside compared to in nonoarside. We conclude that sweep rowers develop a significantly higher flexion knee peak torque and hip mobility depending on oarside. Strength and mobility abnormalities may provide information for training and rehabilitation. Strengthening and stretching training programs to compensate for potential strength and mobility imbalance and thereby reducing the occurrence of injuries may be designed.  相似文献   

16.
The purpose of this study was to determine if an active warm-up affects peak torque (PT), rate of torque development (RTD), and the electromyographic (EMG) and mechanomyographic (MMG) signals. Twenty-one men (mean age ± SD: 24.0 ± 2.7 years) visited the exercise physiology laboratory on 2 occasions. During the first visit, they either performed an active warm-up (10 minutes of stationary cycling at 70% of predicted maximum heart rate) or sat quietly (no warm-up). Participants were then tested for isometric and isokinetic (60°, 180°, and 300°·s) PT, and RTD (measured as S-gradient) on an isokinetic dynamometer. Electromyographic and MMG sensors were placed over the vastus lateralis muscle to monitor the electrical and mechanical aspects of muscle contractions, respectively. The testing protocol used for the first visit was repeated for the second visit, but the preexercise treatment (warm-up, no warm-up) not given during the first visit was administered. The results indicated that an active warm-up did not affect PT, RTD, or measures of muscle activation as reflected by EMG amplitude, EMG frequency, or MMG frequency (p > 0.05). However, MMG amplitude at 180°·s was significantly greater in the warm-up condition compared with the no warm-up condition. The isolated increase in MMG amplitude suggested that warm-up may have affected the mechanical properties of muscle by reducing muscular stiffness or decreasing intramuscular fluid pressure, but that it was not sufficient to influence performance.  相似文献   

17.
The purpose of this study was to determine the influence of speed and distance of muscle shortening on the amount of force depression for voluntary contractions. Two experimental tests were performed. In the first test, subjects performed isometric knee extensor contractions following muscle shortening produced by isokinetic knee extensions over the range 25-50 degrees. In the second test, subjects performed isometric knee extensor contractions following muscle shortening produced by isokinetic knee extensions at two speeds: 20 and 240 degrees /s. Knee extensor moments, surface electromyographical (EMG) signals of quadriceps femoris, and interpolated twitch moments were measured during all contractions and were compared with the corresponding values obtained during purely isometric contractions. Force depression following muscle shortening for the voluntary contractions tested in this study did not depend on the distance or the speed of muscle shortening. These results are in contrast to the corresponding results in the literature obtained using artificial electrical stimulation in which force depression was always found to be directly related to the distance of shortening and inversely related to the speed of shortening. The difference in force depression as a function of the distance and speed of muscle shortening between voluntary and artificial electrical stimulation may be associated with changes in activation following the voluntary shortening contractions, whereas activation is controlled and constant in all artificial stimulation protocols.  相似文献   

18.
The purpose of this study was to compare the effects of warm-up protocols using either whole-body vibration (WBV) or cycle ergometry (CE) on peak torque at 3 different isokinetic speeds and on fatigue in the knee extension exercise. Twenty-seven recreationally trained (age = 23.59 ± 3.87 years) men (n = 14) and women (n = 13) were tested at 3 different isokinetic speeds (60, 180, 300°·s-1) after either WBV or CE warm-up. The WBV consisted of intermittent bouts of 30 seconds of isometric squats at various degrees of hip and knee flexion for a total of 5 minutes. The CE consisted of 5 minutes of pedaling a cycle ergometer at 65-85% of age-predicted max heart rate. Comparisons between the warm-up conditions were analyzed using repeated measures analysis of variance. For the fatigue comparison, subjects completed 50 continuous concentric knee extensions at 240°·s-1. Means from the first 3 repetitions were compared to means from the final 3 repetitions to establish a fatigue index. Conditions were compared through an independent T-test. No significant (p > 0.05) differences were discovered between warm-up conditions at any speed or on the fatigue index. Means were virtually identical at 60°·s-1 (WBV = 142.14 ± 43.61 ft lb-1; CE = 140.64 ± 42.72 ft lb-1), 180° s-1 (WBV = 93.88 ± 35.18 ft lb-1; CE = 96.36 ± 31.53 ft lb-1), and 300°·s-1 (WBV = 78.36 ± 26.04 ft lb-1; CE = 80.13 ± 26.08), and on fatigue percentage (WBV = 51.14 ± 10.06%; CE = 52.96 ± 9.19%). These data suggest that the more traditional 5-minute cycle ergometer warm-up elicits results comparable to a less common vibration warm-up. The findings of this study are that these modalities are comparable under the tested conditions.  相似文献   

19.
Relations between force-velocity characteristics of the multijoint movement of the lower limbs and vertical jump performance were investigated. A total of 67 untrained subjects (age: 19.54 +/- 2.38 years; height: 166.88 +/- 8.53 cm; body mass: 59.14 +/- 10.82 kg, mean +/- SD) performed isometric and isotonic knee-hip extension movements on a servo-controlled dynamometer, and the force-velocity relations were determined. Also, vertical jump (VJ) performance was measured with a jump gauge. The force-velocity relation was described with a linear function so that the maximum isometric force (Fmax) and the maximum unloaded velocity (Vmax) for the knee-hip extension movement were estimated by extrapolation. Maximum isometric force coincided with maximum isometric force, F(0) (F(0)/Fmax = 1.03 +/- 0.24). Maximum isometric force, Vmax, and maximum power output (Pmax) were positively correlated with VJ (r = 0.48, 0.68, and 0.76, respectively; p < 0.001). However, when Fmax, Vmax, and Pmax were normalized with body mass (BM), leg length (LL), and BM, respectively, no correlation was seen between Fmax/BM and VJ (r = 0.24, p > 0.05), and significant correlations were seen between Vmax/LL and VJ (r = 0.56, p < 0.001) and between Pmax/BM and VJ (r = 0.65, p < 0.001). On the other hand, Fmax and Vmax (r = 0.12, p > 0.05) and Fmax/BM and Vmax/LL (r = 0.05, p > 0.05) were not significantly correlated, indicating that Fmax and Vmax were independent variables. The present estimates of Fmax, Vmax, and Pmax can be useful for evaluating the actual performance of multijoint movement of the lower limbs. It is suggested that, although in untrained individuals the speed of movement might be a more important determinant of jump performance, jump performance ability has a potential to improve with increases in strength of the lower limb.  相似文献   

20.
The objective of this study was to investigate the influence of active static stretching on the maximal isometric muscle strength (maximal voluntary contraction [MVC]) and rate of force development (RFD) determined within time intervals of 30, 50, 100, and 200 milliseconds relative to the onset of muscle contraction. Fifteen men (aged 21.3 ± 2.4 years) were submitted on different days to the following tests: (a) familiarization session to the isokinetic dynamometer; (b) 2 maximal isometric contractions for knee extensors in the isokinetic dynamometer to determine MVC and RFD (control); and (c) 2 active static stretching exercises for the dominant leg extensors (10 × 30 seconds for each exercise with a 20-second rest interval between bouts). After stretching, the isokinetic test was repeated (poststretching). Conditions 2 and 3 were performed in random order. The RFD was considered as the mean slope of the moment-time curve at time intervals of 0-30, 0-50, 0-100; 0-150; and 0200 milliseconds relative to the onset of muscle contraction. The MVC was reduced after stretching (285 ± 59 vs. 271 ± 56 N · m, p < 0.01). The RFD at intervals of 0-30, 0-50, and 0-100 milliseconds was unchanged after stretching (p > 0.05). However, the RFD measured at intervals of 0-150 and 0-200 milliseconds was significantly lower after stretching (p < 0.01). It can be concluded that explosive muscular actions of a very short duration (<100 milliseconds) seem less affected by active static stretching when compared with actions using maximal muscle strength.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号