首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.

Background

The ability to perform a cognitive task while walking simultaneously (dual-tasking) is important in real life. However, the psychometric properties of dual-task walking tests have not been well established in stroke.

Objective

To assess the test-retest reliability, concurrent and known-groups validity of various dual-task walking tests in people with chronic stroke.

Design

Observational measurement study with a test-retest design.

Methods

Eighty-eight individuals with chronic stroke participated. The testing protocol involved four walking tasks (walking forward at self-selected and maximal speed, walking backward at self-selected speed, and crossing over obstacles) performed simultaneously with each of the three attention-demanding tasks (verbal fluency, serial 3 subtractions or carrying a cup of water). For each dual-task condition, the time taken to complete the walking task, the correct response rate (CRR) of the cognitive task, and the dual-task effect (DTE) for the walking time and CRR were calculated. Forty-six of the participants were tested twice within 3–4 days to establish test-retest reliability.

Results

The walking time in various dual-task assessments demonstrated good to excellent reliability [Intraclass correlation coefficient (ICC2,1) = 0.70–0.93; relative minimal detectable change at 95% confidence level (MDC95%) = 29%-45%]. The reliability of the CRR (ICC2,1 = 0.58–0.81) and the DTE in walking time (ICC2,1 = 0.11–0.80) was more varied. The reliability of the DTE in CRR (ICC2,1 = -0.31–0.40) was poor to fair. The walking time and CRR obtained in various dual-task walking tests were moderately to strongly correlated with those of the dual-task Timed-up-and-Go test, thus demonstrating good concurrent validity. None of the tests could discriminate fallers (those who had sustained at least one fall in the past year) from non-fallers.

Limitation

The results are generalizable to community-dwelling individuals with chronic stroke only.

Conclusions

The walking time derived from the various dual-task assessments generally demonstrated good to excellent reliability, making them potentially useful in clinical practice and future research endeavors. However, the usefulness of these measurements in predicting falls needs to be further explored. Relatively low reliability was shown in the cognitive outcomes and DTE, which may not be preferred measurements for assessing dual-task performance.  相似文献   

2.

Background

Levamisole, an imidazo(2,1-b)thiazole derivative, has been reported to be a potential antitumor agent. In the present study, we have investigated the mechanism of action of one of the recently identified analogues, 4a (2-benzyl-6-(4′-fluorophenyl)-5-thiocyanato-imidazo[2,1-b][1], [3], [4]thiadiazole).

Materials and Methods

ROS production and expression of various apoptotic proteins were measured following 4a treatment in leukemia cell lines. Tumor animal models were used to evaluate the effect of 4a in comparison with Levamisole on progression of breast adenocarcinoma and survival. Immunohistochemistry and western blotting studies were performed to understand the mechanism of 4a action both ex vivo and in vivo.

Results

We have determined the IC50 value of 4a in many leukemic and breast cancer cell lines and found CEM cells most sensitive (IC50 5 µM). Results showed that 4a treatment leads to the accumulation of ROS. Western blot analysis showed upregulation of pro-apoptotic proteins t-BID and BAX, upon treatment with 4a. Besides, dose-dependent activation of p53 along with FAS, FAS-L, and cleavage of CASPASE-8 suggest that it induces death receptor mediated apoptotic pathway in CEM cells. More importantly, we observed a reduction in tumor growth and significant increase in survival upon oral administration of 4a (20 mg/kg, six doses) in mice. In comparison, 4a was found to be more potent than its parental analogue Levamisole based on both ex vivo and in vivo studies. Further, immunohistochemistry and western blotting studies indicate that 4a treatment led to abrogation of tumor cell proliferation and activation of apoptosis by the extrinsic pathway even in animal models.

Conclusion

Thus, our results suggest that 4a could be used as a potent chemotherapeutic agent.  相似文献   

3.

Purpose

To describe a novel method for quantitative measurement of area parameters in ocular anterior segment ultrasound biomicroscopy (UBM) images using Photoshop software and to assess its intraobserver and interobserver reproducibility.

Methods

Twenty healthy volunteers with wide angles and twenty patients with narrow or closed angles were consecutively recruited. UBM images were obtained and analyzed using Photoshop software by two physicians with different-level training on two occasions. Borders of anterior segment structures including cornea, iris, lens, and zonules in the UBM image were semi-automatically defined by the Magnetic Lasso Tool in the Photoshop software according to the pixel contrast and modified by the observers. Anterior chamber area (ACA), posterior chamber area (PCA), iris cross-section area (ICA) and angle recess area (ARA) were drawn and measured. The intraobserver and interobserver reproducibilities of the anterior segment area parameters and scleral spur location were assessed by limits of agreement, coefficient of variation (CV), and intraclass correlation coefficient (ICC).

Results

All of the parameters were successfully measured by Photoshop. The intraobserver and interobserver reproducibilities of ACA, PCA, and ICA were good, with no more than 5% CV and more than 0.95 ICC, while the CVs of ARA were within 20%. The intraobserver and interobserver reproducibilities for defining the spur location were more than 0.97 ICCs. Although the operating times for both observers were less than 3 minutes per image, there was significant difference in the measuring time between two observers with different levels of training (p<0.001).

Conclusion

Measurements of ocular anterior segment areas on UBM images by Photoshop showed good intraobserver and interobserver reproducibilties. The methodology was easy to adopt and effective in measuring.  相似文献   

4.

Objective

To assess the ability of the urinary biomarkers IGFBP7 (insulin-like growth factor-binding protein 7) and TIMP-2 (tissue inhibitor of metalloproteinase 2) to early predict acute kidney injury (AKI) in high-risk surgical patients.

Introduction

Postoperative AKI is associated with an increase in short and long-term mortality. Using IGFBP7 and TIMP-2 for early detection of cellular kidney injury, thus allowing the early initiation of renal protection measures, may represent a new concept of evaluating renal function.

Methods

In this prospective study, urinary [TIMP-2]×[IGFBP7] was measured in surgical patients at high risk for AKI. A predefined cut-off value of [TIMP-2]×[IGFBP7] >0.3 was used for assessing diagnostic accuracy. Perioperative characteristics were evaluated, and ROC analyses as well as logistic regression models of risk assessment were calculated with and without a [TIMP-2]×[IGFBP7] test.

Results

107 patients were included in the study, of whom 45 (42%) developed AKI. The highest median values of biomarker were detected in septic, transplant and patients after hepatic surgery (1.24 vs 0.45 vs 0.47 ng/l2/1000). The area under receiving operating characteristic curve (AUC) for the risk of any AKI was 0.85, for early use of RRT 0.83 and for 28-day mortality 0.77. In a multivariable model with established perioperative risk factors, the [TIMP-2]×[IGFBP7] test was the strongest predictor of AKI and significantly improved the risk assessment (p<0.001).

Conclusions

Urinary [TIMP-2]×[IGFBP7] test sufficiently detect patients with risk of AKI after major non-cardiac surgery. Due to its rapid responsiveness it extends the time frame for intervention to prevent development of AKI.  相似文献   

5.

Introduction

This study investigated the test–retest reliability for assessment of postural stability using a quantitative method for identification of center of pressure (CoP) spatial patterns of three-dimensional statokinesigrams (3D-SKG).

Methods

Twenty-one healthy participants (11 women, age 26.8±7.2 years, body mass index 25.6±5.3 kg/m²) were submitted to four consecutive 60-s trials while performing undisturbed upright stance with feet together, with or without visual input each. CoP data was used to calculate parameters from the 3D-SKG (quantity of high-density regions, nHDR). Stabilogram (standard deviation, range, maximum velocity) and statokinesigram (elliptical area, average velocity) were also calculated. Intraclass correlation coefficients (ICC2,1 and ICC2,4) and repeated-measures analysis-of-variance were used for statistical analysis.

Results

Significant differences in nHDR among trials were not noticed in both protocols, as well as for any parameter of the stabilogram or statokinesigram (all P>0.05). Reliability for identification of nHDR with or without visual input was either excellent (ICC2,4=0.844 and 0.792, respectively) or fair to good (ICC2,1=0.575 and 0.488, respectively). Reliability of parameters from stabilogram and statokinesigram varied from excellent to poor for either postural task with (ICC2,4 range: 0.961–0.491; ICC2,1 range: 0.859–0.194) or without visual input (ICC2,4 range: 0.990–0.444; ICC2,1 range: 0.960–0.166).

Conclusions

Test–retest reliability for identification of CoP spatial patterns is excellent or fair to good using averaged or single measurements of nHDR, respectively. No learning effect on repeated trials for identification of CoP spatial patterns was detected but deserves further research.  相似文献   

6.

Purpose

To evaluate the repeatability and reproducibility of corneal power measurements obtained by Topcon KR-1W and iTrace, and assess the agreement with measurements obtained by Allegro Topolyzer and IOLMaster.

Methods

The right eyes of 100 normal subjects were prospectively scanned 3 times using all the 4 devices. Another observer performed additional 3 consecutive scans using the Topcon KR-1W and iTrace in the same session. About one week later, the first observer repeated the measurements using the Topcon KR-1W and iTrace. The steep keratometry (Ks), flat keratometry (Kf), mean keratometry (Km), J0 and J45 were analyzed. Repeatability and reproducibility of measurements were evaluated by the within-subject standard deviation (Sw), coefficient of variation (CoV), test-retest repeatability (2.77Sw), and intraclass correlation coefficient (ICC). Agreements between devices were assessed using Bland-Altman analysis and 95% limits of agreement (LoA).

Results

Intraobserver repeatability and interobserver and intersession reproducibility of the Ks, Kf and Km showed a CoV of no more than 0.5%, a 2.77Sw of 0.70 D or less, and an ICC of no less than 0.99. However, J0 and J45 showed poor intraobserver repeatability and interobserver and intersession reproducibility (all ICCs not greater than 0.446). Statistically significant differences existed between Topcon KR-1W and IOLMaster, Topcon KR-1W and iTrace, Topcon KR-1W and Topolyzer, iTrace and Topolyzer, iTrace and IOLMaster for Ks, Kf and Km measurements (all P < 0.05). The mean differences between Topcon KR-1W, iTrace, and the other 2 devices were small. The 95% LoA were approximately 1.0 D to 1.5 D for all measurements.

Conclusions

The Ks, Kf and Km obtained by Topcon KR-1W and iTrace showed excellent intraobserver repeatability and interobserver and intersession reproducibility in normal eyes. The agreement between Topcon KR-1W and Topolyzer, Topcon KR-1W and IOLMaster, iTrace and Topolyzer, iTrace and IOLMaster, Topcon KR-1W and iTrace were not so good, they should not be interchangeable in clinical application. Given that the intraobserver repeatability and interobserver and intersession reproducibility of corneal astigmatism measurements obtained by Topcon KR-1W and iTrace were poor, it should be cautious that Topcon KR-1W and iTrace were applied for the preparation of toric lens implantation.  相似文献   

7.

[Purpose]

The purpose of this study was to identify the effect of detraining on motor unit potential area (SMUP), muscular function and physical performance, according to CNTF gene polymorphism.

[Methods]

For this study, GG (normal homozygote, n = 8) group and GA + AA (mutation heterozygote and homozygote, n = 10) group were divided by CNTF gene polymorphism and both groups were performed detraining for 4 weeks. The data was analyzed by two-way repeated measures ANOVA for verifying the differences between two groups and interaction using SPSS (ver. 20.0) statistical program.

[Results]

The results were as follows. First, changes in body composition were measured but there was no significant interaction effect between time and group. Seconds, changes in SMUP were measured by SEMG. Interaction effect between time and group was found lateral vastus during isokinetic exercise of 180°/sec (p < .05). Third, changes in isokinetic muscle strength of 60°/sec and 180°/sec were measured but there was no significant interaction effect. Fourth, significant statistical differences were not showed changes of sports performance after detraining.

[Conclusion]

In conclusion, there were no significantly differences between GG and GA + AA group after detraining, therefore, further study will be considered a matter in various its interventions such as serum levels of CNTF and changes in receptors and muscle fiber types.  相似文献   

8.

Objective

To study the normal values of the retinal oxygen saturation in Rhesus monkeys and to evaluated repeatability and reproducibility of retinal oxygen saturation measurements.

Methods

Eighteen adult Rhesus macaque monkeys were included in this experimental study. An Oxymap T1 retinal oximeter (Oxymap, Reykjavik, Iceland) was used to perform oximetry on all subjects. Global arterial (SaO2) and venous oxygen saturation (SvO2), arteriovenous difference in SO2 were measured. In the first examination, each eye was imaged three times. At the following two examinations, each eye was imaged once. All examinations were finished in one month. P values were calculated to evaluate the difference between the measurements during three visits by performing an ANOVA. Intra-visit and inter-visit intraclass correlation coefficient (ICC) was determined.

Results

At baseline, the average SaO2 and SvO2 were 89.48 ± 2.64% and 54.85 ± 2.18%, respectively. The global A-V difference was 34.63 ± 1.91%. The difference between the three visits was not significant (p>0.05). The highest A-V difference in SO2 and lowest saturations were found in the inferotemporal quadrant. Intra-session and inter-visit repeatability were both high. For all oxygen saturation parameters, the ICC values of the intra-session repeatability ranged between 0.92 and 0.96. As found previously, a relatively high ICC value for inter-visit repeatability also was found for all oxygen saturation measurements, ranging between 0.86 and 0.94, with the lowest values in the infero-nasal quadrant.

Conclusions

Our study is the first to describe retinal SO2 in healthy Rhesus monkeys. In normal monkey eyes, the reproducibility and repeatability of retinal oximetry oxygen saturation measurements were high in the retinal arterioles and venules. Our results support that Oxymap T1 retinal oximetry is a suitable and reliable technique in monkey studies.  相似文献   

9.

Background

The precise definition of the post-operative resection status in high-grade gliomas (HGG) is crucial for further management. We aimed to assess the feasibility of assessment of the resection status with early post-operative positron emission tomography (PET) using [18F]O-(2-[18F]-fluoroethyl)-L-tyrosine ([18F]FET).

Methods

25 patients with the suspicion of primary HGG were enrolled. All patients underwent pre-operative [18F]FET-PET and magnetic resonance imaging (MRI). Intra-operatively, resection status was assessed using 5-aminolevulinic acid (5-ALA). Imaging was repeated within 72h after neurosurgery. Post-operative [18F]FET-PET was compared with MRI, intra-operative assessment and clinical follow-up.

Results

[18F]FET-PET, MRI and intra-operative assessment consistently revealed complete resection in 12/25 (48%) patients and incomplete resection in 6/25 cases (24%). In 7 patients, PET revealed discordant findings. One patient was re-resected. 3/7 experienced tumor recurrence, 3/7 died shortly after brain surgery.

Conclusion

Early assessment of the resection status in HGG with [18F]FET-PET seems to be feasible.  相似文献   

10.

Background and Aims

Noninvasive models have been developed for fibrosis assessment in patients with chronic hepatitis B. However, the sensitivity, specificity and diagnostic accuracy in evaluating liver fibrosis of these methods have not been validated and compared in the same group of patients. The aim of this study was to verify the diagnostic performance and reproducibility of ten reported noninvasive models in a large cohort of Asian CHB patients.

Methods

The diagnostic performance of ten noninvasive models (HALF index, FibroScan, S index, Zeng model, Youyi model, Hui model, APAG, APRI, FIB-4 and FibroTest) was assessed against the liver histology by ROC curve analysis in CHB patients. The reproducibility of the ten models were evaluated by recalculating the diagnostic values at the given cut-off values defined by the original studies.

Results

Six models (HALF index, FibroScan, Zeng model, Youyi model, S index and FibroTest) had AUROCs higher than 0.70 in predicting any fibrosis stage and 2 of them had best diagnostic performance with AUROCs to predict F≥2, F≥3 and F4 being 0.83, 0.89 and 0.89 for HALF index, 0.82, 0.87 and 0.87 for FibroScan, respectively. Four models (HALF index, FibroScan, Zeng model and Youyi model) showed good diagnostic values at given cut-offs.

Conclusions

HALF index, FibroScan, Zeng model, Youyi model, S index and FibroTest show a good diagnostic performance and all of them, except S index and FibroTest, have good reproducibility for evaluating liver fibrosis in CHB patients.

Registration Number

ChiCTR-DCS-07000039.  相似文献   

11.

Objectives

To study the value of assessing renal masses using different methods in parameter approaches and to determine whether BOLD MRI is helpful in differentiating RCC from benign renal masses, differentiating clear-cell RCC from renal masses other than clear-cell RCC and determining the tumour grade.

Methods

Ninety-five patients with 139 renal masses (93 malignant and 46 benign) who underwent abdominal BOLD MRI were enrolled. R2* values were derived from the largest cross-section (R2*largest) and from the whole tumour (R2*whole). Intra-observer and inter-observer agreements were analysed based on two measurements by the same observer and the first measurement from each observer, respectively, and these agreements are reported with intra-class correlation coefficients and 95% confidence intervals. The diagnostic value of the R2* value in the evaluation was assessed with receiver-operating characteristic analysis.

Results

The intra-observer agreement was very good for R2*largest and R2*whole (all > 0.8). The inter-observer agreement of R2*whole (0.75, 95% confidence interval: 0.69~0.79) was good and was significantly improved compared with the R2*largest (0.61, 95% confidence interval: 0.52~0.68), as there was no overlap in the 95% confidence interval of the intra-class correlation coefficients. The diagnostic value in differentiating renal cell carcinoma from benign lesions with R2*whole (AUC=0.79/0.78[observer1/observer2]) and R2*largest (AUC=0.75[observer1]) was good and significantly higher (p=0.01 for R2*largest[observer2] vs R2*whole[observer2], p<0.01 for R2*whole[observer1] vs R2*largest[observer2]) than R2*largest for observer 2 (AUC=0.64). For the grading of clear-cell RCC, both R2*whole and R2*largest were good (all > 0.7) and were not significantly different (p=0.89/0.93 for R2*largest vs R2*whole[observer1/observer2], 0.96 for R2*whole[observer1] vs R2*largest[observer2] and 0.96 for R2*whole [observer2] vs R2*largest[observer1]).

Conclusions

BOLD MRI could provide a feasible parameter for differentiating renal cell carcinoma from benign renal masses and for predicting clear-cell renal cell carcinoma grading. Compared with the largest cross-section, assessing the whole tumour provides better inter-observer agreement in parameter measurement for differentiating renal cell carcinoma from benign renal masses.  相似文献   

12.

Background

We hypothesized that heterogeneity exists within the Global Initiative for Chronic Obstructive Lung Disease (GOLD) 1 spirometric category and that different subgroups could be identified within this GOLD category.

Methods

Pre-randomization study participants from two clinical trials were symptomatic/asymptomatic GOLD 1 chronic obstructive pulmonary disease (COPD) patients and healthy controls. A hierarchical cluster analysis used pre-randomization demographics, symptom scores, lung function, peak exercise response and daily physical activity levels to derive population subgroups.

Results

Considerable heterogeneity existed for clinical variables among patients with GOLD 1 COPD. All parameters, except forced expiratory volume in 1 second (FEV1)/forced vital capacity (FVC), had considerable overlap between GOLD 1 COPD and controls. Three-clusters were identified: cluster I (18 [15%] COPD patients; 105 [85%] controls); cluster II (45 [80%] COPD patients; 11 [20%] controls); and cluster III (22 [92%] COPD patients; 2 [8%] controls). Apart from reduced diffusion capacity and lower baseline dyspnea index versus controls, cluster I COPD patients had otherwise preserved lung volumes, exercise capacity and physical activity levels. Cluster II COPD patients had a higher smoking history and greater hyperinflation versus cluster I COPD patients. Cluster III COPD patients had reduced physical activity versus controls and clusters I and II COPD patients, and lower FEV1/FVC versus clusters I and II COPD patients.

Conclusions

The results emphasize heterogeneity within GOLD 1 COPD, supporting an individualized therapeutic approach to patients.

Trial registration

www.clinicaltrials.gov. NCT01360788 and NCT01072396.  相似文献   

13.

Background

Although infant lung function (ILF) testing is widely practiced in developed Western countries it is not typically performed in Eastern countries, and lung measurements are scarce for Asian infants. Therefore, this study aimed to establish normal reference values for Taiwanese infants.

Materials and Methods

Full-term infants without any chronic diseases and major anomalies were enrolled in the Prediction of Allergies in Taiwanese Children (PATCH) cohort study. Detailed medical data, such as body weight and length, birth history, and histories of previous illness and hospitalization were recorded. Lung function measurements such as analysis of tidal breathing, passive respiratory mechanics, and forced tidal expiratory flow-volume curves were obtained through Jaeger Masterscreen BabyBody Paediatrics System. Multiple linear analyses were performed to determine various parameters of the lung function tests.

Results

ILF test parameters were collected from 126 infants, and 189 tests were performed. The results revealed that the ratio of time to peak expiratory flow to total expiratory time, the ratio of volume to peak expiratory flow to total expiratory volume, and the ratio of inspiratory time to total respiratory time remained relatively constant despite differences in age. However, body length is the strongest independent variable influencing tidal volume, respiratory rate, resistance, compliance, and maximal expiratory flow at functional residual capacity.

Conclusion

According to our review of relevant literature, this is the first study to establish a reference data of ILF tests in the Asian population. This study provided reference values and regression equations for several variables of lung function measurements in healthy infants aged less than 2 years. With these race-specific reference data, ILF can more precisely and efficiently diagnose respiratory diseases in infants of Chinese ethnicity.  相似文献   

14.

[Purpose]

Attention-deficit/hyperactivity disorder (ADHD) is a heritable, chronic, neurobehavioral disorder that is characterized by hyperactivity, inattention, and impulsivity. It is commonly believed that the symptoms of ADHD are closely associated with hypo-function of the dopamine system. Dopamine D2 receptor activation decreases the excitability of dopamine neurons, as well as the release of dopamine. Physical exercise is known to improve structural and functional impairments in neuropsychiatric disorders. We investigated the therapeutic effect of exercise on ADHD.

[Methods]

Open field task and elevated-plus maze task were used in the evaluation of hyperactivity and impulsivity, respectively. Dopamine D2 receptor expression in the substantia nigra and striatum were evaluated by western blotting.

[Results]

The present results indicated that ADHD rats showed hyperactivity and impulsivity. Dopamine D2 receptor expression in the substantia nigra and striatum were increased in ADHD rats. Exercise alleviated hyperactivity and impulsivity in ADHD rats. Furthermore, dopamine D2 receptor expression in ADHD rats was also decreased by exercise.

[Conclusion]

We thus showed that exercise effectively alleviates ADHD-induced symptoms through enhancing dopamine D2 expression in the brain.  相似文献   

15.

Purpose

To detect the causative mutation for congenital posterior polar cataracts in a five-generation Chinese family and further explore the potential pathogenesis of this disease.

Methods

Coding exons, with flanking sequences of five candidate genes, were screened using direct DNA sequencing. The identified mutations were confirmed by restriction fragment length polymorphism (RFLP) analysis. A full-length wild-type or an Y219* mutant aquaporin0 (AQP0) fused with an N-terminal FLAG tag, was transfected into HEK293T cells. For co-localization studies, FLAG-WT-AQP0 and Myc-Y219*-AQP0 constructs were co-transfected. Quantitative real-time RT-PCR, western blotting and immunofluorescence studies were performed to determine protein expression levels and sub-cellular localization, respectively.

Results

We identified a novel nonsense mutation in MIP (c.657 C>G; p.Y219*) (major intrinsic protein gene) that segregates with congenital posterior polar cataract in a Chinese family. This mutation altered a highly conserved tyrosine to a stop codon (Y219*) within AQP0.When FLAG-WT-AQP0 and FLAG-Y219*-AQP0 expression constructs were singly transfected into HEK 293T cells, mRNA expression showed no significant difference between the wild-type and the mutant, while Y219*-AQP0 protein expression was significantly lower than that of wild-type AQP0. Wild-type AQP0 predominantly localized to the plasma membrane, while the mutated protein was abundant within the cytoplasm of HEK293T cells. However, when FLAG-WT-AQP0 andMyc-MU-AQP0were co-expressed, both proteins showed high fluorescence in the cytoplasm.

Conclusions

The novel nonsense mutation in the MIP gene (c.657 C>G) identified in a Chinese family may cause posterior polar cataracts. The dominant negative effect of the mutated protein on the wild-type protein interfered with the trafficking of wild-type protein to the cell membrane and both the mutant and wild-type protein were trapped in the cytoplasm. Consequently, both wild-type and mutant protein lost their function as a water channel on the cell membrane, and may result in a cataract phenotype. Our data also expands the spectrum of known MIP mutations.  相似文献   

16.

Purpose

To evaluate the intrasession reproducibility of various thickness parameters used to diagnose and follow-up glaucoma, in particular circumpapillary total retinal thickness (cpTR) provided by the RS-3000 optical coherence tomograph (OCT).

Methods

Fifty-three healthy eyes of 28 subjects underwent three consecutive imaging with the RS-3000 Advance OCT (NIDEK, Aichi,Japan) to evaluate the intrasession reproducibility of circumpapillary total retinal thickness (cpTR), circumpapillary retinal nerve fiber layer thickness (cpRNFL), macular ganglion cell complex thickness (mGCC) and macular total retina thickness (mTR) measurements. Intraclass correlation (ICC), coefficient of variation (CV) and reproducibility coefficient (RC) were calculated for each parameter.

Results

The ICC and CV values for mean cpTR and cpRNFL were 0.987 and 0.897, and 0.60% and 2.81%, respectively. The RC values for the mean cpTR and cpRNFL were 5.95 μm and 9.04 μm, respectively. For all cpTR parameters the ICC values were higher and both the CV and RC values were lower than those for the corresponding cpRNFL parameters. The ICC and CV values for superior mGCC, inferior mGCC, superior mTR and inferior mTR were 0.983, 0.980, 0.983 and 0.988, and 0.84%, 0.98%, 0.48% and 0.43%, respectively. The RC values for superior mGCC, inferior mGCC, superior mTR and inferior mTR were 2.86 μm, 3.12 μm, 4.41μm and 4.43 μm, respectively.

Conclusions

Intrasession reproducibility of cpTR, mGCC and mTR measurements made on healthy eyes was high. Repeatability of cpTR measurements was better than that of the corresponding cpRNFL measurements. These results suggest that future clinical investigations addressing detection of glaucoma and glaucomatous progression with the RS-3000 OCT may benefit from focusing on the cpTR parameters.  相似文献   

17.

Purpose

To evaluate repeatability and reproducibility of anterior corneal power measurements obtained with a new corneal topographer OphthaTOP (Hummel AG, Germany) and agreement with measurements by a rotating Scheimpflug camera (Pentacam HR, Oculus, Germany) and an automated keratometer (IOLMaster, Carl Zeiss Meditec, Germany).

Methods

The right eyes of 79 healthy subjects were prospectively measured three times with all three devices. Another examiner performed three additional scans with the OphthaTOP in the same session. Within one week, the first examiner repeated the measurements using the OphthaTOP. The flat simulated keratometry (Kf), steep K (Ks), mean K (Km), J0, and J45 were noted. Repeatability and reproducibility of measurements were assessed by within-subject standard deviation (Sw), repeatability (2.77 Sw), coefficient of variation (CoV), and intraclass correlation coefficient (ICC). Agreement between devices was assessed using 95% limits of agreement (LoA).

Results

Intraobserver repeatability and interobserver and intersession reproducibility of all measured parameters showed a 2.77 Sw of 0.29 diopter or less, a CoV of less than 0.24%, and an ICC of more than 0.906. Statistically significant differences (P<0.001) were found between the parameters analyzed by the three devices, except J0 and J45. The mean differences between OphthaTOP and the other two devices were small, and the 95% LoA was narrow for all results.

Conclusions

The OphthaTOP showed excellent intraobserver repeatability and interobserver and intersession reproducibility of corneal power measurements. Good agreements with the other two devices in these parameters were found in healthy eyes.  相似文献   

18.

Background

Mutations in the integral membrane protein 2B [1], also known as BRI2 [2], a type II trans-membrane domain protein cause two autosomal dominant neurodegenerative diseases, Familial British and Danish Dementia [3]. In these conditions, accumulation of a C-terminal peptide (ABri and ADan) cleaved off from the mutated precursor protein by the pro-protein convertase furin [4], leads to amyloid deposition in the walls of blood vessels and parenchyma of the brain. Recent advances in the understanding of the generation of amyloid in Alzheimer''s disease has lead to the finding that BRI2 interacts with the Amyloid Precursor Protein (APP), decreasing the efficiency of APP processing to generate Aβ [5], [6], [7]. The interaction between the two precursors, APP and BRI2, and possibly between Aβ and ABri or ADan, could be important in influencing the rate of amyloid production or the tendency of these peptides to aggregate.

Methodology/Principal Findings

We have generated the first BRI2 Danish Knock-In (FDDKI) murine model of FDD, expressing the pathogenic decamer duplication in exon 6 of the BRI2 gene. FDDKI mice do not show any evident abnormal phenotype, with normal brain histology and no detectable amyloid deposition in blood vessel walls or parenchyma.

Conclusions/Significance

This new murine mouse model will be important to further understand the interaction between APP and BRI2, and to provide insights into the molecular basis of FDD.  相似文献   

19.

[Purpose]

Functional near-infrared spectroscopy (fNIRS) provides functional imaging of cortical activations by measuring regional oxy- and deoxy-hemoglobin (Hb) changes in the forehead during a cognitive task. There are, however, potential problems regarding NIRS signal contamination by non-cortical hemodynamic (NCH) variables such as skin blood flow, middle cerebral artery blood flow, and heart rate (HR), which are further complicated during acute exercise. It is thus necessary to determine the appropriate post-exercise timing that allows for valid NIRS assessment during a task without any increase in NCH variables. Here, we monitored post-exercise changes in NCH parameters with different intensities of exercise.

[Methods]

Fourteen healthy young participants cycled 30, 50 and 70% of their peak oxygen uptake (Vo2peak) for 10 min per intensity, each on different days. Changes in skin blood flow velocity (SBFv), middle cerebral artery mean blood velocity (MCA Vmean) and HR were monitored before, during, and after the exercise.

[Results]

Post-exercise levels of both SBFv and HR in contrast to MCA Vmean remained high compared to basal levels and the times taken to return to baseline levels for both parameters were delayed (2-8 min after exercise), depending upon exercise intensity.

[Conclusion]

These results indicate that the delayed clearance of NCH variables of up to 8 min into the post-exercise phase may contaminate NIRS measurements, and could be a limitation of NIRS-based neuroimaging studies.  相似文献   

20.

Introduction

Our aim was to estimate the longitudinal effect of Socioeconomic status (SES) on lung function growth of Mexican children and adolescents.

Materials and Methods

A cohort of Mexican children in third grade of primary school was followed with spirometry twice a year for 6 years through secondary school. Multilevel mixed-effects lineal models were fitted for the spirometric variables of 2,641 respiratory-healthy Mexican children. Monthly family income (in 2002 U.S. dollars [USD]) and parents’ years completed at school were used as proxies of SES.

Results

Individuals with higher SES tended to have greater height for age, and smaller sitting height/standing height and crude lung function. For each 1-year increase of parents’ schooling, Forced expiratory volume in 1 sec (FEV1) and Forced vital capacity (FVC) increased 8.5 (0.4%) and 10.6 mL (0.4%), respectively (p <0.05) when models were adjusted for gender. Impact of education on lung function was reduced drastically or abolished on adjusting by anthropometric variables and ozone.

Conclusions

Higher parental schooling and higher monthly family income were associated with higher lung function in healthy Mexican children, with the majority of the effect likely due to the increase in height-for-age.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号