首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.

Context

Technological advancements have led craniofacial researchers and clinicians into the era of three-dimensional digital imaging for quantitative evaluation of craniofacial growth and treatment outcomes.

Objective

To give an overview of soft-tissue based methods for quantitative longitudinal assessment of facial dimensions in children until six years of age and to assess the reliability of these methods in studies with good methodological quality.

Data Source

PubMed, EMBASE, Cochrane Library, Web of Science, Scopus and CINAHL were searched. A hand search was performed to check for additional relevant studies.

Study Selection

Primary publications on facial growth and treatment outcomes in children younger than six years of age were included.

Data Extraction

Independent data extraction by two observers. A quality assessment instrument was used to determine the methodological quality. Methods, used in studies with good methodological quality, were assessed for reliability expressed as the magnitude of the measurement error and the correlation coefficient between repeated measurements.

Results

In total, 47 studies were included describing 4 methods: 2D x-ray cephalometry; 2D photography; anthropometry; 3D imaging techniques (surface laser scanning, stereophotogrammetry and cone beam computed tomography). In general the measurement error was below 1 mm and 1° and correlation coefficients range from 0.65 to 1.0.

Conclusion

Various methods have shown to be reliable. However, at present stereophotogrammetry seems to be the best 3D method for quantitative longitudinal assessment of facial dimensions in children until six years of age due to its millisecond fast image capture, archival capabilities, high resolution and no exposure to ionizing radiation.  相似文献   

2.

Aim

The purpose of this study was to present and validate an innovative semi-automatic approach to quantify the accuracy of the surgical outcome in relation to 3D virtual orthognathic planning among patients who underwent bimaxillary surgery.

Material and Method

For the validation of this new semi-automatic approach, CBCT scans of ten patients who underwent bimaxillary surgery were acquired pre-operatively. Individualized 3D virtual operation plans were made for all patients prior to surgery. During surgery, the maxillary and mandibular segments were positioned as planned by using 3D milled interocclusal wafers. Consequently, post-operative CBCT scan were acquired. The 3D rendered pre- and postoperative virtual head models were aligned by voxel-based registration upon the anterior cranial base. To calculate the discrepancies between the 3D planning and the actual surgical outcome, the 3D planned maxillary and mandibular segments were segmented and superimposed upon the postoperative maxillary and mandibular segments. The translation matrices obtained from this registration process were translated into translational and rotational discrepancies between the 3D planning and the surgical outcome, by using the newly developed tool, the OrthoGnathicAnalyser. To evaluate the reproducibility of this method, the process was performed by two independent observers multiple times.

Results

Low intra-observer and inter-observer variations in measurement error (mean error < 0.25 mm) and high intraclass correlation coefficients (> 0.97) were found, supportive of the observer independent character of the OrthoGnathicAnalyser. The pitch of the maxilla and mandible showed the highest discrepancy between the 3D planning and the postoperative results, 2.72° and 2.75° respectively.

Conclusion

This novel method provides a reproducible tool for the evaluation of bimaxillary surgery, making it possible to compare larger patient groups in an objective and time-efficient manner in order to optimize the current workflow in orthognathic surgery.  相似文献   

3.

Purpose

To rebuild the three-dimensional (3-D) model of the anterior segment by high-speed swept-source optical coherence tomography (SSOCT) and evaluate the repeatability of measurement for the parameters of capsule-intraocular lens (C-IOL) complex.

Methods

Twenty-two pseudophakic eyes from 22 patients were enrolled. Three continuous SSOCT measurements were performed in all eyes and the tomograms obtained were used for 3-D reconstruction. The output data were used to evaluate the measurement repeatability. The parameters included postoperative aqueous depth (PAD), the area and diameter of the anterior capsule opening (Area and D), IOL tilt (IOL-T), horizontal, vertical, and space decentration of the IOL, anterior capsule opening, and IOL-anterior capsule opening.

Results

PAD, IOL-T, Area, D, and all decentration measurements showed high repeatability. Repeated measure analysis showed there was no statistically significant difference among the three continuous measurements (all P > .05). Pearson correlation analysis showed high correlation between each pair of them (all r >0.90, P<0.001). ICCs were all more than 0.9 for all parameters. The 95% LoAs of all parameters were narrow for comparison of three measurements, which showed high repeatability for three measurements.

Conclusion

SSOCT is available to be a new method for the 3-D measurement of C-IOL complex after cataract surgery. This method presented high repeatability in measuring the parameters of the C-IOL complex.  相似文献   

4.

Objective

To verify the reliability and clinical feasibility of a self-developed navigation system based on an augmented reality technique for endoscopic sinus and skull base surgery.

Materials and Methods

In this study we performed a head phantom and cadaver experiment to determine the display effect and accuracy of our navigational system. We compared cadaver head-based simulated operations, the target registration error, operation time, and National Aeronautics and Space Administration Task Load Index scores of our navigation system to conventional navigation systems.

Results

The navigation system developed in this study has a novel display mode capable of fusing endoscopic images to three-dimensional (3-D) virtual images. In the cadaver head experiment, the target registration error was 1.28 ± 0.45 mm, which met the accepted standards of a navigation system used for nasal endoscopic surgery. Compared with conventional navigation systems, the new system was more effective in terms of operation time and the mental workload of surgeons, which is especially important for less experienced surgeons.

Conclusion

The self-developed augmented reality navigation system for endoscopic sinus and skull base surgery appears to have advantages that outweigh those of conventional navigation systems. We conclude that this navigational system will provide rhinologists with more intuitive and more detailed imaging information, thus reducing the judgment time and mental workload of surgeons when performing complex sinus and skull base surgeries. Ultimately, this new navigational system has potential to increase the quality of surgeries. In addition, the augmented reality navigational system could be of interest to junior doctors being trained in endoscopic techniques because it could speed up their learning. However, it should be noted that the navigation system serves as an adjunct to a surgeon’s skills and knowledge, not as a substitute.  相似文献   

5.

Purpose

Superimposition of two dimensional preoperative and postoperative facial images, including radiographs and photographs, are used to evaluate the surgical changes after orthognathic surgery. Recently, three dimensional (3D) imaging has been introduced allowing more accurate analysis of surgical changes. Surface based registration and voxel based registration are commonly used methods for 3D superimposition. The aim of this study was to evaluate and compare the accuracy of the two methods.

Materials and methods

Pre-operative and 6 months post-operative cone beam CT scan (CBCT) images of 31 patients were randomly selected from the orthognathic patient database at the Dental Hospital and School, University of Glasgow, UK. Voxel based registration was performed on the DICOM images (Digital Imaging Communication in Medicine) using Maxilim software (Medicim-Medical Image Computing, Belgium). Surface based registration was performed on the soft and hard tissue 3D models using VRMesh (VirtualGrid, Bellevue City, WA). The accuracy of the superimposition was evaluated by measuring the mean value of the absolute distance between the two 3D image surfaces. The results were statistically analysed using a paired Student t-test, ANOVA with post-hoc Duncan test, a one sample t-test and Pearson correlation coefficient test.

Results

The results showed no significant statistical difference between the two superimposition methods (p<0.05). However surface based registration showed a high variability in the mean distances between the corresponding surfaces compared to voxel based registration, especially for soft tissue. Within each method there was a significant difference between superimposition of the soft and hard tissue models.

Conclusions

There were no significant statistical differences between the two registration methods and it was unlikely to have any clinical significance. Voxel based registration was associated with less variability. Registering on the soft tissue in isolation from the hard tissue may not be a true reflection of the surgical change.  相似文献   

6.

Background

Although conventional two-dimensional (2D) methods for orthognathic surgery planning are still popular, the use of three-dimensional (3D) simulation is steadily increasing. In facial asymmetry cases such as in cleft lip/palate patients, the additional information can dramatically improve planning accuracy and outcome. The purpose of this study is to investigate which parameters are changed most frequently in transferring a traditional 2D plan to 3D simulation, and what planning parameters can be better adjusted by this method.

Patients and Methods

This prospective study enrolled 30 consecutive patients with cleft lip and/or cleft palate (mean age 18.6±2.9 years, range 15 to 32 years). All patients received two-jaw single-splint orthognathic surgery. 2D orthodontic surgery plans were transferred into a 3D setting. Severe bony collisions in the ramus area after 2D plan transfer were noted. The position of the maxillo-mandibular complex was evaluated and eventually adjusted. Position changes of roll, midline, pitch, yaw, genioplasty and their frequency within the patient group were recorded as an alternation of the initial 2D plan. Patients were divided in groups of no change from the original 2D plan and changes in one, two, three and four of the aforementioned parameters as well as subgroups of unilateral, bilateral cleft lip/palate and isolated cleft palate cases. Postoperative OQLQ scores were obtained for 20 patients who finished orthodontic treatment.

Results

83.3% of 2D plans were modified, mostly concerning yaw (63.3%) and midline (36.7%) adjustments. Yaw adjustments had the highest mean values in total and in all subgroups. Severe bony collisions as a result of 2D planning were seen in 46.7% of patients. Possible asymmetry was regularly foreseen and corrected in the 3D simulation.

Conclusion

Based on our findings, 3D simulation renders important information for accurate planning in complex cleft lip/palate cases involving facial asymmetry that is regularly missed in conventional 2D planning.  相似文献   

7.

Purpose

To determine the reproducibility of automated segmentation of the three-dimensional (3D) lamina cribrosa (LC) microarchitecture scanned in-vivo using optical coherence tomography (OCT).

Methods

Thirty-nine eyes (8 healthy, 19 glaucoma suspects and 12 glaucoma) from 49 subjects were scanned twice using swept-source (SS−) OCT in a 3.5×3.5×3.64 mm (400×400×896 pixels) volume centered on the optic nerve head, with the focus readjusted after each scan. The LC was automatically segmented and analyzed for microarchitectural parameters, including pore diameter, pore diameter standard deviation (SD), pore aspect ratio, pore area, beam thickness, beam thickness SD, and beam thickness to pore diameter ratio. Reproducibility of the parameters was assessed by computing the imprecision of the parameters between the scans.

Results

The automated segmentation demonstrated excellent reproducibility. All LC microarchitecture parameters had an imprecision of less or equal to 4.2%. There was little variability in imprecision with respect to diagnostic category, although the method tends to show higher imprecision amongst healthy subjects.

Conclusion

The proposed automated segmentation of the LC demonstrated high reproducibility for 3D LC parameters. This segmentation analysis tool will be useful for in-vivo studies of the LC.  相似文献   

8.

Aim

To investigate the clinical application of a technique for patient set-up verification in breast cancer radiotherapy based on a 3D surface image registration system.

Background

Accurate and reproducible patient set-up is a prerequisite to correctly deliver fractionated radiotherapy. Various approaches are available to verify and correct patient setup for 3D image acquisition in a radiation treatment room.

Materials and methods

The study analyzed the setup reproducibility of 15 patients affected by breast cancer and candidates for conformal radiotherapy by using the AlignRT system (VisionRT, London, UK). At the initial setup, electronic portal imaging device (EPID) images were compared with Digitally Reconstructed Radiographs (DRRs) and a reference three-dimensional (3D) surface image was obtained by AlignRT. Surface images were acquired prior to every subsequent setup procedure. The systematic and random errors along longitudinal and vertical directions were measured and compared for the two systems.

Results

The procedure for surface registration, image acquisition and comparison with the reference image took less than 1 min on average. The T test for systematic error showed no significant difference between the 2 verification systems along the longitudinal (p = 0.69) and vertical (p = 0.67) axes. The T-test for random error showed a significant difference between the 2 systems along the vertical axis (p = 0.05).

Conclusion

AlignRT is fast, simple, non-invasive and seems to be reliable in detecting patient setup errors. Our results suggest that it could be used to assess the setup reproducibility for breast cancer patients.  相似文献   

9.

Background

To study the morphology of the human spine and new spinal fixation methods, scientists require cadaveric specimens, which are dependent on donation. However, in most countries, the number of people willing to donate their body is low. A 3D printed model could be an alternative method for morphology research, but the accuracy of the morphology of a 3D printed model has not been determined.

Methods

Forty-five computed tomography (CT) scans of cervical, thoracic and lumbar spines were obtained, and 44 parameters of the cervical spine, 120 parameters of the thoracic spine, and 50 parameters of the lumbar spine were measured. The CT scan data in DICOM format were imported into Mimics software v10.01 for 3D reconstruction, and the data were saved in .STL format and imported to Cura software. After a 3D digital model was formed, it was saved in Gcode format and exported to a 3D printer for printing. After the 3D printed models were obtained, the above-referenced parameters were measured again.

Results

Paired t-tests were used to determine the significance, set to P<0.05, of all parameter data from the radiographic images and 3D printed models. Furthermore, 88.6% of all parameters of the cervical spine, 90% of all parameters of the thoracic spine, and 94% of all parameters of the lumbar spine had Intraclass Correlation Coefficient (ICC) values >0.800. The other ICC values were <0.800 and >0.600; none were <0.600.

Conclusion

In this study, we provide a protocol for printing accurate 3D spinal models for surgeons and researchers. The resulting 3D printed model is inexpensive and easily obtained for spinal fixation research.  相似文献   

10.

Objective

To investigate image quality and radiation dose of CT colonography (CTC) with adaptive iterative dose reduction three-dimensional (AIDR3D).

Methods

Ten segments of porcine colon phantom were collected, and 30 pedunculate polyps with diameters ranging from 1 to 15 mm were simulated on each segment. Image data were acquired with tube voltage of 120 kVp, and current doses of 10 mAs, 20 mAs, 30 mAs, 40 mAs, 50 mAs, respectively. CTC images were reconstructed using filtered back projection (FBP) and AIDR3D. Two radiologists blindly evaluated image quality. Quantitative evaluation of image quality included image noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR). Qualitative image quality was evaluated with a five-score scale. Radiation dose was calculated based on dose-length product. Ten volunteers were examined supine 50 mAs with FBP and prone 20 mAs with AIDR3D, and image qualities were assessed. Paired t test was performed for statistical analysis.

Results

For 20 mAs with AIDR3D and 50 mAs with FBP, image noise, SNRs and CNRs were (16.4 ± 1.6) HU vs. (16.8 ± 2.6) HU, 1.9 ± 0.2 vs. 1.9 ± 0.4, and 62.3 ± 6.8 vs. 62.0 ± 6.2, respectively; qualitative image quality scores were 4.1 and 4.3, respectively; their differences were all not statistically significant. Compared with 50 mAs with FBP, radiation dose (1.62 mSv) of 20 mAs with AIDR3D was decreased by 60.0%. There was no statistically significant difference in image noise, SNRs, CNRs and qualitative image quality scores between prone 20 mAs with AIDR3D and supine 50 mAs with FBP in 10 volunteers, the former reduced radiation dose by 61.1%.

Conclusion

Image quality of CTC using 20 mAs with AIDR3D could be comparable to standard 50 mAs with FBP, radiation dose of the former reduced by about 60.0% and was only 1.62 mSv.  相似文献   

11.

Objective

The purpose of this study is to provide an optimized method to reconstruct the structure of the upper airway (UA) based on magnetic resonance imaging (MRI) that can faithfully show the anatomical structure with a smooth surface without artificial modifications.

Methods

MRI was performed on the head and neck of a healthy young male participant in the axial, coronal and sagittal planes to acquire images of the UA. The level set method was used to segment the boundary of the UA. The boundaries in the three scanning planes were registered according to the positions of crossing points and anatomical characteristics using a Matlab program. Finally, the three-dimensional (3D) NURBS (Non-Uniform Rational B-Splines) surface of the UA was constructed using the registered boundaries in all three different planes.

Results

A smooth 3D structure of the UA was constructed, which captured the anatomical features from the three anatomical planes, particularly the location of the anterior wall of the nasopharynx. The volume and area of every cross section of the UA can be calculated from the constructed 3D model of UA.

Conclusions

A complete scheme of reconstruction of the UA was proposed, which can be used to measure and evaluate the 3D upper airway accurately.  相似文献   

12.

Background

The mouse is the most commonly used animal model in biomedical research because of recent advances in molecular genetic techniques. Studies related to eye movement in mice are common in fields such as ophthalmology relating to vision, neuro-otology relating to the vestibulo-ocular reflex (VOR), neurology relating to the cerebellum’s role in movement, and psychology relating to attention. Recording eye movements in mice, however, is technically difficult.

Methods

We developed a new algorithm for analyzing the three-dimensional (3D) rotation vector of eye movement in mice using high-speed video-oculography (VOG). The algorithm made it possible to analyze the gain and phase of VOR using the eye’s angular velocity around the axis of eye rotation.

Results

When mice were rotated at 0.5 Hz and 2.5 Hz around the earth’s vertical axis with their heads in a 30° nose-down position, the vertical components of their left eye movements were in phase with the horizontal components. The VOR gain was 0.42 at 0.5 Hz and 0.74 at 2.5 Hz, and the phase lead of the eye movement against the turntable was 16.1° at 0.5 Hz and 4.88° at 2.5 Hz.

Conclusions

To the best of our knowledge, this is the first report of this algorithm being used to calculate a 3D rotation vector of eye movement in mice using high-speed VOG. We developed a technique for analyzing the 3D rotation vector of eye movements in mice with a high-speed infrared CCD camera. We concluded that the technique is suitable for analyzing eye movements in mice. We also include a C++ source code that can calculate the 3D rotation vectors of the eye position from two-dimensional coordinates of the pupil and the iris freckle in the image to this article.  相似文献   

13.

Objectives

In this study, we develop a microdensitometry method using full width at half maximum (FWHM) analysis of the retinal vascular structure in a spectral-domain optical coherence tomography (SD-OCT) image and present the application of this method in the morphometry of arteriolar changes during hypertension.

Methods

Two raters using manual and FWHM methods measured retinal vessel outer and lumen diameters in SD-OCT images. Inter-rater reproducibility was measured using coefficients of variation (CV), intraclass correlation coefficient and a Bland-Altman plot. OCT images from forty-three eyes of 43 hypertensive patients and 40 eyes of 40 controls were analyzed using an FWHM approach; wall thickness, wall cross-sectional area (WCSA) and wall to lumen ratio (WLR) were subsequently calculated.

Results

Mean difference in inter-rater agreement ranged from -2.713 to 2.658 μm when using a manual method, and ranged from -0.008 to 0.131 μm when using a FWHM approach. The inter-rater CVs were significantly less for the FWHM approach versus the manual method (P < 0.05). Compared with controls, the wall thickness, WCSA and WLR of retinal arterioles were increased in the hypertensive patients, particular in diabetic hypertensive patients.

Conclusions

The microdensitometry method using a FWHM algorithm markedly improved inter-rater reproducibility of arteriolar morphometric analysis, and SD-OCT may represent a promising noninvasive method for in vivo arteriolar morphometry.  相似文献   

14.

Background

Understanding the three-dimensional (3-D) micro-architecture of lung tissue can provide insights into the pathology of lung disease. Micro computed tomography (µCT) has previously been used to elucidate lung 3D histology and morphometry in fixed samples that have been stained with contrast agents or air inflated and dried. However, non-destructive microstructural 3D imaging of formalin-fixed paraffin embedded (FFPE) tissues would facilitate retrospective analysis of extensive tissue archives of lung FFPE lung samples with linked clinical data.

Methods

FFPE human lung tissue samples (n = 4) were scanned using a Nikon metrology µCT scanner. Semi-automatic techniques were used to segment the 3D structure of airways and blood vessels. Airspace size (mean linear intercept, Lm) was measured on µCT images and on matched histological sections from the same FFPE samples imaged by light microscopy to validate µCT imaging.

Results

The µCT imaging protocol provided contrast between tissue and paraffin in FFPE samples (15mm x 7mm). Resolution (voxel size 6.7 µm) in the reconstructed images was sufficient for semi-automatic image segmentation of airways and blood vessels as well as quantitative airspace analysis. The scans were also used to scout for regions of interest, enabling time-efficient preparation of conventional histological sections. The Lm measurements from µCT images were not significantly different to those from matched histological sections.

Conclusion

We demonstrated how non-destructive imaging of routinely prepared FFPE samples by laboratory µCT can be used to visualize and assess the 3D morphology of the lung including by morphometric analysis.  相似文献   

15.

Objectives

To assess the impact of a standardized pre-operative telephone checklist on the rate of late cancellations of ambulatory surgery (AMBUPROG trial).

Design

Multicenter, two-arm, parallel-group, open-label randomized controlled trial.

Setting

11 university hospital ambulatory surgery units in Paris, France.

Participants

Patients scheduled for ambulatory surgery and able to be reached by telephone.

Intervention

A 7-item checklist designed to prevent late cancellation, available in five languages and two versions (for children and adults), was administered between 7 and 3 days before the planned date of surgery, by an automated phone system or a research assistant. The control group received standard management alone.

Main Outcome Measures

Rate of cancellation on the day of surgery or the day before.

Results

The study population comprised 3900 patients enrolled between November 2012 and September 2013: 1950 patients were randomized to the checklist arm and 1950 patients to the control arm. The checklist was administered to 68.8% of patients in the intervention arm, 1002 by the automated phone system and 340 by a research assistant. The rate of late cancellation did not differ significantly between the checklist and control arms (109 (5.6%) vs. 113 (5.8%), adjusted odds ratio [95% confidence interval] = 0.91 [0.65–1.29], (p = 0.57)). Checklist administration revealed that 355 patients (28.0%) had not undergone tests ordered by the surgeon or anesthetist, and that 254 patients (20.0%) still had questions concerning the fasting state.

Conclusions

A standardized pre-operative telephone checklist did not avoid late cancellations of ambulatory surgery but enabled us to identify several frequent causes.

Trial Registration

ClinicalTrials.gov NCT01732159  相似文献   

16.

Purpose

To assess the inter session reproducibility of automatic segmented MRI-derived measures by FreeSurfer in a group of subjects with normal-appearing MR images.

Materials and Methods

After retrospectively reviewing a brain MRI database from our institute consisting of 14,758 adults, those subjects who had repeat scans and had no history of neurodegenerative disorders were selected for morphometry analysis using FreeSurfer. A total of 34 subjects were grouped by MRI scanner model. After automatic segmentation using FreeSurfer, label-wise comparison (involving area, thickness, and volume) was performed on all segmented results. An intraclass correlation coefficient was used to estimate the agreement between sessions. Wilcoxon signed rank test was used to assess the population mean rank differences across sessions. Mean-difference analysis was used to evaluate the difference intervals across scanners. Absolute percent difference was used to estimate the reproducibility errors across the MRI models. Kruskal-Wallis test was used to determine the across-scanner effect.

Results

The agreement in segmentation results for area, volume, and thickness measurements of all segmented anatomical labels was generally higher in Signa Excite and Verio models when compared with Sonata and TrioTim models. There were significant rank differences found across sessions in some labels of different measures. Smaller difference intervals in global volume measurements were noted on images acquired by Signa Excite and Verio models. For some brain regions, significant MRI model effects were observed on certain segmentation results.

Conclusions

Short-term scan-rescan reliability of automatic brain MRI morphometry is feasible in the clinical setting. However, since repeatability of software performance is contingent on the reproducibility of the scanner performance, the scanner performance must be calibrated before conducting such studies or before using such software for retrospective reviewing.  相似文献   

17.

Background

The convenience and availability of real-time three-dimensional echocardiography (RT3DE) makes it an attractive candidate for assessing right ventricle function. However, the viability of RT3DE is not conclusive.

Aim of Study

This study aims to evaluate RT3DE relative to cardiac magnetic resonance and 2-dimensional echocardiography (2DE) for measuring right ventricular systolic function in patients with pulmonary hypertension.

Methods

Patients with pulmonary hypertension (n = 23) underwent cardiac magnetic resonance, 2DE, and RT3DE. Specifically, 2DE was used to measure the right ventricular index of myocardial performance (RIMP), fractional area change, tricuspid annular plane systolic excursion (TAPSE), and tissue Doppler-derived tricuspid annular systolic velocity (S′). Cardiac magnetic resonance and RT3DE were used to measure right ventricular end-diastolic volume (RVEDV) and end-systolic volume (RVESV). The right ventricular ejection fraction (RVEF) was calculated.

Results

Regarding the measurements taken by 2DE, RVEF positively correlated with fractional area change (r = 0.595, P = 0.003) and S′(r = 0.489, P = 0.018), and negatively correlated with RIMP (r = −0.745, P = 0.000). There was no association between RVEF and TAPSE (r = −0.029, P = 0.896). There existed a close correlation between the values of RVEDV, RVESV, and RVEF as measured by RT3DE and CMR respectively (P<0.001); Bland-Altmanan analyses showed good agreement between them.

Conclusion

RT3DE was a viable method for noninvasive, accurate assessment of right ventricular systolic function in patients with pulmonary hypertension.  相似文献   

18.

Background

Mitochondria, as recently suggested, might be involved in iron sensing and signalling pathways in plant cells. For a better understanding of the role of these organelles in mediating the Fe deficiency responses in plant cells, it is crucial to provide a full overview of their modifications occurring under Fe-limited conditions. The aim of this work is to characterize the ultrastructural as well as the biochemical changes occurring in leaf mitochondria of cucumber (Cucumis sativus L.) plants grown under Fe deficiency.

Methodology/Results

Mitochondrial ultrastructure was investigated by transmission electron microscopy (TEM) and electron tomography techniques, which allowed a three-dimensional (3D) reconstruction of cellular structures. These analyses reveal that mitochondria isolated from cucumber leaves appear in the cristae junction model conformation and that Fe deficiency strongly alters both the number and the volume of cristae. The ultrastructural changes observed in mitochondria isolated from Fe-deficient leaves reflect a metabolic status characterized by a respiratory chain operating at a lower rate (orthodox-like conformation) with respect to mitochondria from control leaves.

Conclusions

To our knowledge, this is the first report showing a 3D reconstruction of plant mitochondria. Furthermore, these results suggest that a detailed characterization of the link between changes in the ultrastructure and functionality of mitochondria during different nutritional conditions, can provide a successful approach to understand the role of these organelles in the plant response to Fe deficiency.  相似文献   

19.

Background

The aim of this study was to evaluate the survival outcomes and toxicity of postoperative chemoradiotherapy with capecitabine and concurrent intensity-modulated radiotherapy (IMRT) or three-dimensional conformal radiotherapy (3D-CRT) in patients with stage II and III rectal cancer.

Patients

We recruited 184 patients with pathologically proven, stage II or III rectal cancer. Following total mesorectal excision (TME), the patients were treated with capecitabine and concurrent IMRT/3D-CRT. The treatment regimen consisted of two cycles of oral capecitabine (1600 mg/m2/day), administered twice daily from day 1–14 of radiotherapy, followed by a 7-day rest. The median pelvic dose was 50 Gy in 25 fractions. Oxaliplatin-based adjuvant chemotherapy was administered after the chemoradiotherapy.

Results

The 5-year overall survival, disease-free survival and locoregional control (LRC) rates were 85.1%, 80% and 95.4%, respectively. Grade 3 and 4 toxicities were observed in 28.3% of patients during treatment. Grade 3 or 4 late toxicity, including neurotoxicity or gastrointestinal toxicity, was only observed in nine patients (4.9%).

Conclusions

This study demonstrated that capecitabine chemotherapy with concurrent IMRT/3D-CRT following TME is safe, is well tolerated and achieves superior LRC and favorable survival rates, with acceptable toxicity.  相似文献   

20.

Purpose

The aim of this study was the systematic image quality evaluation of coronary CT angiography (CTA), reconstructed with the 3 different levels of adaptive iterative dose reduction (AIDR 3D) and compared to filtered back projection (FBP) with quantum denoising software (QDS).

Methods

Standard-dose CTA raw data of 30 patients with mean radiation dose of 3.2 ± 2.6 mSv were reconstructed using AIDR 3D mild, standard, strong and compared to FBP/QDS. Objective image quality comparison (signal, noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), contour sharpness) was performed using 21 measurement points per patient, including measurements in each coronary artery from proximal to distal.

Results

Objective image quality parameters improved with increasing levels of AIDR 3D. Noise was lowest in AIDR 3D strong (p≤0.001 at 20/21 measurement points; compared with FBP/QDS). Signal and contour sharpness analysis showed no significant difference between the reconstruction algorithms for most measurement points. Best coronary SNR and CNR were achieved with AIDR 3D strong. No loss of SNR or CNR in distal segments was seen with AIDR 3D as compared to FBP.

Conclusions

On standard-dose coronary CTA images, AIDR 3D strong showed higher objective image quality than FBP/QDS without reducing contour sharpness.

Trial Registration

Clinicaltrials.gov NCT00967876  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号