首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
This study is designed to evaluate the visual outcomes, accuracy, and predictability of corneal flaps with different thicknesses created by 60-kHz femtosecond laser according to different corneal thicknesses in the patients with low and moderate refractive error. A total of 182 eyes were divided according to the central corneal thickness (470μm–499 μm in Group A, 500μm–549 μm in Group B, and 550μm–599 μm in Group C) and underwent femtosecond laser-assisted LASIK for a target corneal flap thickness (100 μm for Group A, 110 μm for Group B, and 120 μm for Group C). Uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), and refractive status were examined. The flap thickness of each eye was measured by anterior segment optical coherence tomography (AS-OCT) on 30 points at 1-month follow-up to assess the accuracy and predictability. Postoperatively, at least 75% of eyes had a UDVA of 20/16 or better, less than 2% of eyes lost one line, over 30% of eyes gained one or more lines in CDVA, at least 95% of eyes had astigmatism of less than 0.25 D, all eyes achieved a correction within ±1.00 D from the target spherical equivalent refraction. The visual and refractive outcomes did not differ significantly in all groups (P >0.05). The mean flap thickness was 100.36± 4.32 μm (range: 95–113 μm) in Group A, 111.64 ± 3.62 μm (range: 108–125 μm) in Group B, and 122.32 ± 2.88 μm (range: 112–128 μm) in Group C. The difference at each measured point among the three groups was significant (P < 0.05). The accuracy and predictability were satisfactory in all three groups. In conclusion, this customized treatment yielded satisfactory clinical outcomes with accurate and predictable flap thickness for patients with low and moderate refractive error.  相似文献   

2.
Corneal grafts for Descemet’s Stripping Automated Endothelial Keratoplasty are commonly prepared using mechanical microkeratomes. However, the cuts produced in such way render corneal lenticules that are thinner centrally than peripherally, thus inducing a hyperopic shift. Here we describe a novel device for preparing donor corneal grafts, in which a single low-energy femtosecond laser system is used as both a light source for optical coherence tomography and for cutting the graft illuminating from the endothelial side. The same laser is first utilized to obtain three-dimensional optical coherence tomography images of the donor tissue for guiding the dissection and obtaining grafts of uniform thickness with no applanation or contact. This device allows an optimal procedure for preparing consistently thin posterior grafts for transplantation.  相似文献   

3.

Purpose

To describe cytokines, chemokines and growth factors profiles in patients undergoing cataract surgery with femtosecond laser pretreatment and investigate their relationships with the postoperative in vivo inflammation index.

Methods

Aqueous humor was collected from 22 eyes after femtosecond laser pretreatment and from 22 eyes at the beginning of routine cataract surgery. The levels of 45 inflammation-related mediators were measured using multiplex fluorescent bead-based immunoassays. Laser flare photometry was measured preoperatively and at 1 day, 7 days and 30 days postoperatively.

Results

Compared with the control group, the femtosecond laser treatment group showed significantly higher aqueous humor levels of fibroblast growth factor (FGF-2), tumor necrosis factor (TNF)-α, leukemia inhibitor factor (LIF), interleukin (IL)-1ra and IL-18, and significantly lower aqueous humor levels of IL-9, platelet-derived growth factor (PDGF)-BB, eotaxin and TNF-β. Postoperative aqueous flare was significantly greater in the manual cataract surgery group at 1 day (p<0.001), 7days (p<0.001) and 30 days (p = 0.002).No correlation was found between the analyzed mediators and the aqueous flare values.

Conclusions

The expression profiles of cytokines, chemokines and growth factors and the correlations of these profiles with the in vivo inflammatory indexes for patients undergoing cataract surgery with femtosecond laser pretreatment were identified. Our data indicate a disturbance of postoperative inflammation response after femtosecond laser treatment.  相似文献   

4.

Purpose

To investigate the morphology of corneal caps in femtosecond laser small incision lenticule extraction (SMILE) and its relation to the refractive outcomes.

Methods

A prospective study of fifty-four corneal caps created with VisuMax femtosecond laser were examined using an Fourier-domain optical coherence tomography at 1 day, 1 week, 1 month and 6 months after SMILE. The cap thickness at nine points on each of the four meridians (0°, 45°, 90°, 135°) and the diameter were measured. Cap morphology, changes over time and its correlation with refractive outcomes were assessed.

Results

The mean achieved central cap thickness were (108.74±5.06) µm at 6 months and (107.32±4.81 ) µm at 1 month postoperatively, significantly thinner than that at 1 day (110.81±7.95) µm and 1 week (109.58±7.48 ) µm (P<0.05). The mean diameter on 0° meridian was (7.61±0.07) mm, significantly larger than that on 90° meridian (7.57±0.06) mm (P = 0.001). Cap morphology showed good regularity, except that the differences of points in two pairs were significant at 1 day postoperatively. The uniformity was consistent over time and the central cap thickness was thinner than those in the paracentral and peripheral areas. The refractive outcomes stabilized within 1 month. Uncorrected distance visual acuity (UDVA) was correlated to the central cap thickness at 1 day and 1 week (both rs = 0.33, p<0.05). The uniformity index was correlated with UDVA (rs = 0.34, p<0.05) and corrected distance visual acuity (rs = 0.32, p<0.05) at 1 week postoperatively.

Conclusions

Corneal caps of SMILE are predictable with good reproducibility, regularity and uniformity. Cap morphology might have a mild effect on refractive outcomes in the early stage. Further study should focus on the impact on the visual quality.  相似文献   

5.

Purpose

To evaluate corneal reinnervation, and the corresponding corneal sensitivity and keratocyte density after small incision lenticule extraction (SMILE) and femtosecond laser in situ keratomileusis (FS-LASIK).

Methods

In this prospective, non-randomized observational study, 18 patients (32 eyes) received SMILE surgery, and 22 patients (42 eyes) received FS-LASIK surgery to correct myopia. The corneal subbasal nerve density and microscopic morphological changes in corneal architecture were evaluated by confocal microscopy prior to surgery and at 1 week, 1 month, 3 months, and 6 months after surgery. A correlation analysis was performed between subbasal corneal nerve density and the corresponding keratocyte density and corneal sensitivity.

Results

The decrease in subbasal nerve density was less severe in SMILE-treated eyes than in FS-LASIK-treated eyes at 1 week (P = 0.0147), 1 month (P = 0.0243), and 3 months (P = 0.0498), but no difference was detected at the 6-month visit (P = 0.5277). The subbasal nerve density correlated positively with central corneal sensitivity in both groups (r = 0.416, P<0.0001, and r = 0.2567, P = 0.0038 for SMILE group and FS-LASIK group, respectively). The SMILE-treated eyes have a lower risk of developing peripheral empty space with epithelial cells filling in (P = 0.0005).

Conclusions

The decrease in subbasal nerve fiber density was less severe in the SMILE group than the FS-LASIK group in the first 3 months following the surgeries. The subbasal nerve density was correlated with central corneal sensitivity.  相似文献   

6.
Age-related macular degeneration (AMD) is the leading cause of legal blindness in the western nations beyond 50 years of age. The most frequent cause for severe visual loss is the growth of neovascular membrances from the choroid into the subretinal space. This usually results in irreversible degeneration of the overlying retina. Surgical removal of the membrane is feasible, however, usually results in functional loss of apposing retinal photoreceptors since retinal pigment epithelial (RPE) cells are removed concurrently due to their tight adherence to the neovascular complex. Therefore, various attempts have been undertaken to fill the resulting RPE cell defect with either heterologous or autologous RPE cell transplants. So far cell survival, function and subsequent visual function has been disappointing. To minimize trauma and resulting dedifferentiation harvesting in the eye and transplantation in whole sheets and without temporary removal from the eyes would be desirable. This may be achieved by isolating grafts consisting of choroid, Bruch's membrance and RPE cells from the peripheral retina and transplantation of this graft under the neurosensory retina after removal of the choroidal neovascularization. However, the choroidal component of such a graft would be expected to interfere with diffusion of metabolites to and from the retina. Therefore, outcome would be expected to be better if the choroidal tissue would be removed before translocation. In preclinical experiments we used a 308 nm UV AIDA excimer laser to microablate choroidal tissue from such a graft in human donor eyes.  相似文献   

7.
The corneal test (CT) for rabies diagnosis was evaluated in samples from 313 subjects of different species. Some of the subjects were inoculated experimentally and others were naturally infected. When the CT was compared with immunofluorescence staining and mouse inoculation tests on brains of the same subjects, a sensitivity of 41.7% and a specificity of 100% were found. The authors conclude that a positive CT result would confirm the diagnosis of rabies, but a negative one would not exclude the possibility of disease.  相似文献   

8.

Introduction

Phenothiazines when exposed to white light or to UV radiation undergo a variety of reactions that result in degradation of parental compound and formation of new species. This process is slow and may be sped up with exposure to high energy light such as that produced by a laser.

Methods

Varying concentrations of Chlorpromazine Hydrochloride (CPZ) (2–20 mg/mL in distilled water) were exposed to 266 nm laser beam (time intervals: 1–24 hrs). At distinct intervals the irradiation products were evaluated by spectrophotometry between 200–1500 nm, Thin Layer Chromatography, High Pressure Liquid Chromatography (HPLC) - Diode Array Detection, HPLC tandem mass spectrometry, and for activity against the CPZ sensitive test organism Staphylococcus aureus ATCC 25923.

Results

CPZ exposure to 266 nm laser beam of given energy levels yielded species, whose number increased with duration of exposure. Although the major species produced were Promazine (PZ), hydroxypromazine or PZ sulfoxide, and CPZ sulfoxide, over 200 compounds were generated with exposure of 20 mg/mL of CPZ for 24 hrs. Evaluation of the irradiation products indicated that the bioactivity against the test organism increased despite the total disappearance of CPZ, that is due, most probably, to one or more new species that remain yet unidentified.

Conclusions

Exposure of CPZ to a high energy (6.5 mJ) 266 nm laser beam yields rapidly a large number of new and stable species. For biological grade phenothiazines (in other words knowing the impurities in the samples: solvent and solute) this process may be reproducible because one can control within reasonably low experimental errors: the concentration of the parent compound, the laser beam wavelength and average energy, as well as the duration of the exposure time. Because the process is “clean” and rapid, it may offer advantages over the pyrogenically based methods for the production of derivatives.  相似文献   

9.
Plasma Physics Reports - The article deals with interaction of an extraordinary laser wave of high amplitude with inhomogeneous plasma in a strong magnetic field in the vicinity of twice the...  相似文献   

10.

Purpose

To investigate the changes in dry eye symptoms and clinical signs and corneal sensitivity after small incision lenticule extraction (SMILE) and femtosecond LASIK (femto-LASIK).

Design

Prospective, non-randomized comparative study.

Methods

The study included a total of 71 eyes of 71 patients; the SMILE group comprised 38 eyes of 38 patients, and the femto-LASIK group comprised 33 eyes of 33 patients. Ocular Surface Disease Index (OSDI), Tear film breakup time (TBUT), the Schirmer test without anesthesia (S1T), corneal fluorescein staining, and central corneal sensation were evaluated before surgery and at 1 week, 1 month, 3 months, and 6 months after surgery.

Results

OSDI scores in both groups were increased immediately and returned to preoperative level at 1 month after surgeries. The TBUT values in both groups were reduced after surgeries relative to their preoperative scores. Patients in SMILE group were less likely to have corneal staining compared with those in the femto-LASIK group ([odds ratio] OR = 0.50, 95% [confidence interval] CI 0.28 to 0.93, P = 0.03). Central corneal sensitivity was decreased at all postoperative time points in both groups. However, the central corneal sensation scores in the SMILE group were greater than that in the femto-LASIK group at all of the postoperative time points (all P<0.05).

Conclusions

SMILE surgeries resulted in a short-term increase in dry eye symptoms, tear film instability, and loss of corneal sensitivity. Furthermore, SMILE surgeries have superiority over femto-LASIK in lower risk of postoperative corneal staining and less reduction of corneal sensation.  相似文献   

11.
Surface-tension-confined microfluidic devices are platforms for manipulating 2D droplets based on patterned surfaces with special wettability.They have great potential for various applications,but are still in the early stages of development and face some challenges that need to be addressed.This study,inspired by the Wenzel and slippery transition of rose petal,develops a Patterned Oil-triggered Wenzel-slippery Surface(POWS)to examine the microfluidic devices.A laser-chemical composite method is established to fabricate POWSs,which take rose-petal-like microstructures as wettability pattern and a superamphiphobic surface as the background.The prepared POWSs switched between high adhesion superhydropho-bic state and the slippery liquid-infused surface state through adding or removing the lubricant oil.In the high adhesion superhydrophobic state,the droplets can be sticked on the surface.In the slippery liquid-infused state,the droplet can slide along the wettability pattern as the designed route.A POWS-based droplet reactor is further constructed,on which,the droplets can be remotely controlled to move,mix and react,as required.Such a POWS,which manipulates droplets with surface tension controlled by the switchable wettability patterns,would be a promising candidate to construct multiple surface-tension-confined microfluidic devices.In addition,the fabrication technique and design principle proposed here may aid the development of various field related to the bio-inspired surfaces,such as water collection,desalination and high throughput analysis,etc.  相似文献   

12.
激光在农业和医疗等方面已有广泛应用,并且取得增产和一定疗效,但也有费介现象(暂称后继效应或潜在效应).激光辐照生物体虽然是局部的有限时间,但对由多种生物大分子组成的牛物体的影响可能是综合的.为了探索激光生物学效应的分子机理,以便进一步认识和掌握激光的生物学效应,对激光直接辐照有生物活性的生物大分子一酵母甘露聚糖产生的效应进行电镜扫描观察和紫外及红外光谱法分析研究.实验结果表明:308 nm 激光(单脉冲25 mJ,33.3 ml-34.4 ml,脉冲频率2次/s)无论是固定辐照时间(45 s)变化样晶所置距离,或反之固定样品所置距离(290 mm)改变辐照时广开J为15 s、30 s、45 s或60 s,都能引起受照样品的结构(构象)变化,特别足糖分子结构中富含的-OH、-CH-OH、-C-O-c-、-N-C=0、-C=0等结构部件处的IR谱线对激光能最变化影响敏感.它们既是糖分子内或分子间形成氧键和糖苷键的结构基础部件,又是甘露聚糖(Man-nan)糖基化其他生物大分子进而影响它们在生物信息流中作用的重要结构部件.结果显示糖在激光牛物效应中起了不可忽视的作用,这为综合探索激光生物效应分子机理和糖在生物信息传递中的作用提供了重要线索,为选择甘露聚糖作为生物导弹载体提供了参考依据.  相似文献   

13.
14.

Purpose

To measure horizontal and vertical lamina cribrosa (LC) tilt angles and investigate associated factors using prototype optical coherence tomography (OCT) with a broad wavelength laser light source.

Design

Cross sectional study.

Methods

Twenty-eight no glaucoma eyes (from 15 subjects) and 25 glaucoma eyes (from 14 patients) were enrolled. A total of 300 optic nerve head B-scans were obtained in 10 µm steps and the inner edge of Bruch''s membrane opening (BMO) was identified as the reference plane. The vertical and horizontal angles between BMO line and approximate the best-fitting line for the surface of the LC were measured and potential associated factors were estimated with univariate and multivariate logistic regression analyses.

Results

The median (interquartile range) horizontal and vertical tilt angles were 7.10 (2.43–11.45) degrees and 4.15 (2.60–6.85) degrees in eyes without glaucoma and 8.50 (4.40–14.10) degrees and 9.30 (6.90–14.15) degrees in glaucoma eyes, respectively. The refractive errors had a statistically significant association with horizontal LC tilt angles (coefficients, −1.53 per diopter) and glaucoma had a significant correlation with vertical tilt angles (coefficients, 6.56) using multiple logistic regression analysis (p<0.001).

Conclusions

OCT allowed evaluation of the internal tilting of the LC compared with the BMO. The horizontal internal LC tilt angle was correlated with refractive errors, corresponding to myopic physiological changes, and vertical internal LC tilt was correlated with glaucoma, corresponding to glaucomatous pathological changes. These parameters have important implications for investigation of the correlation between myopia, glaucoma and LC morphological features.  相似文献   

15.
Advances in the development of cornea substitutes by tissue engineering techniques have focused on the use of decellularized tissue scaffolds. In this work, we evaluated different chemical and physical decellularization methods on small intestine tissues to determine the most appropriate decellularization protocols for corneal applications. Our results revealed that the most efficient decellularization agents were the SDS and triton X-100 detergents, which were able to efficiently remove most cell nuclei and residual DNA. Histological and histochemical analyses revealed that collagen fibers were preserved upon decellularization with triton X-100, NaCl and sonication, whereas reticular fibers were properly preserved by decellularization with UV exposure. Extracellular matrix glycoproteins were preserved after decellularization with SDS, triton X-100 and sonication, whereas proteoglycans were not affected by any of the decellularization protocols. Tissue transparency was significantly higher than control non-decellularized tissues for all protocols, although the best light transmittance results were found in tissues decellularized with SDS and triton X-100. In conclusion, our results suggest that decellularized intestinal grafts could be used as biological scaffolds for cornea tissue engineering. Decellularization with triton X-100 was able to efficiently remove all cells from the tissues while preserving tissue structure and most fibrillar and non-fibrillar extracellular matrix components, suggesting that this specific decellularization agent could be safely used for efficient decellularization of SI tissues for cornea TE applications.  相似文献   

16.
目的:建立脉冲1 064 nm Nd:YAG激光致视网膜出血性损伤及非出血性损伤动物模型,为治疗药物评价提供技术基础.方法:应用自由振荡脉冲及调Q脉冲1 064 nm激光照射青紫蓝灰兔视网膜,通过在光路中加人透镜获得直径200μm眼底光斑,加入衰减片改变角膜入射激光能量.照射即刻对损伤应用检眼镜进行实时观察,并用眼底相...  相似文献   

17.
Mutation of Bacteriophage with Respect to Type of Plaque   总被引:18,自引:0,他引:18  
Hershey AD 《Genetics》1946,31(6):620-640
  相似文献   

18.

Purpose

To assess the clinical outcomes of femtosecond laser-assisted keratoplasty (FLAK) using the VisuMax femtosecond laser system, and to compare them with those of conventional penetrating keratoplasty (PK).

Methods

We retrospectively examined 20 eyes of 20 consecutive patients undergoing FLAK and 20 eyes of 20 age- and diagnosis-matched patients undergoing conventional PK. We quantitatively assessed corneal astigmatism, refractive astigmatism, and corrected visual acuity, 1, 3, and 6 months postoperatively, and endothelial cell density 6 months postoperatively.

Results

Corneal and refractive astigmatism after FLAK were significantly lower after FLAK than that after conventional PK at 3 and 6 months postoperatively (p = 0.04 and p = 0.03, respectively, Mann-Whitney U test). FLAK provided significantly faster visual recovery than conventional PK at 1 month postoperatively (p = 0.02), but not at 3 and 6 months postoperatively (p = 0.52 and p = 0.80, respectively). We found no significant differences in the change in endothelial cell density between the two groups (p = 0.30).

Conclusions

FLAK using the VisuMax femtosecond laser system induces significantly less corneal and refractive astigmatism than conventional PK, and provides significantly faster visual recovery in the early postoperative period, possibly because the geometry of the donor-recipient matching is more physiological and requires less tight sutures. It is suggested that FLAK has advantages over conventional PK, in terms of astigmatism and fast visual recovery.  相似文献   

19.
Diffusion MRI and tractography allow for investigation of the architectural configuration of white matter in vivo, offering new avenues for applications like presurgical planning. Despite the promising outlook, there are many pitfalls that complicate its use for (clinical) application. Amongst these are inaccuracies in the geometry of the diffusion profiles on which tractography is based, and poor alignment with neighboring profiles. Recently developed contextual processing techniques, including enhancement and well-posed geometric sharpening, have shown to result in sharper and better aligned diffusion profiles. However, the research that has been conducted up to now is mainly of theoretical nature, and so far these techniques have only been evaluated by visual inspection of the diffusion profiles. In this work, the method is evaluated in a clinically relevant application: the reconstruction of the optic radiation for epilepsy surgery. For this evaluation we have developed a framework in which we incorporate a novel scoring procedure for individual pathways. We demonstrate that, using enhancement and sharpening, the extraction of an anatomically plausible reconstruction of the optic radiation from a large amount of probabilistic pathways is greatly improved in three healthy controls, where currently used methods fail to do so. Furthermore, challenging reconstructions of the optic radiation in three epilepsy surgery candidates with extensive brain lesions demonstrate that it is beneficial to integrate these methods in surgical planning.  相似文献   

20.
目的 :研究 10 64nm和 53 2nm波长激光在激光能量为 14 0mJ/pulse(脉冲 )时对犬心肌切割效率。方法 :用Q开关Nd :YAG 10 64和 53 2nm波长脉冲激光分别照射犬离体和在体心肌组织 ,光学显微镜和偏振光学显微镜行组织学分析 ,观察不同条件下激光切割组织的深度和光热对组织的损伤。结果 :离体和在体实验 ,10 64nm波长激光的切割效率高于 53 2nm(p <0 .0 1)。在体和离体实验显示 10 64nm激光能量和重复率相同时 ,所致的切割效率无明显差异 (p >0 .0 5) ,血液对 10 64nm激光的切割效率影响较小。相反 ,在 53 2nm时血液对其影响较大 ,相同的激光能量和重复率 ,离体实验切割效率高于在体 (p <0 .0 1)。 10 64nm激光所致的光热和机械损伤均轻于 53 2nm激光。结论 :在切割效率方面 ,10 64nm激光比 53 2nm更适用于TMLR。 10 64nmQ开关Nd :YAG激光可通过光导纤维传输 ,是TMLR的一个有潜力的激光源  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏