首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
PURPOSE: In a meta-analysis of the literature we evaluated the present knowledge of the material properties of cortical and cancellous bone to answer the question whether the available data are sufficient to realize anisotropic finite element (FE)-models of the proximal femur. MATERIAL AND METHOD: All studies that met the following criteria were analyzed: Young's modulus, tensile, compressive and torsional strengths, Poisson's ratio, the shear modulus and the viscoelastic properties had to be determined experimentally. The experiments had to be carried out in a moist environment and at room temperature with freshly removed and untreated human cadaverous femurs. All material properties had to be determined in defined load directions (axial, transverse) and should have been correlated to apparent density (g/cm(3)), reflecting the individually variable and age-dependent changes of bone material properties. RESULTS: Differences in Young's modulus of cortical [cancellous] bone at a rate of between 33% (58%) (at low apparent density) and 62% (80%) (at high apparent density), are higher in the axial than in the transverse load direction. Similar results have been seen for the compressive strength of femoral bone. For the tensile and torsional strengths, Poisson's ratio and the shear modulus, only ultimate values have been found without a correlation to apparent density. For the viscoelastic behaviour of bone only data of cortical bone and in axial load direction have been described up to now. CONCLUSIONS: Anisotropic FE-models of the femur could be realized for most part with the summarized material properties of bone if characterized by apparent density and load directions. Because several mechanical properties have not been correlated to these main criteria, further experimental investigations will be necessary in future.  相似文献   

2.
The objective of this study was to examine the dependence of the elastic properties of cortical bone as a transversely isotropic material on its porosity. The longitudinal Young's modulus, transverse Young's modulus, longitudinal shear modulus, transverse shear modulus, and longitudinal Poisson's ratio of cortical bone were determined from eighteen groups of longitudinal and transverse specimens using tensile and torsional tests on a servo-hydraulic material testing system. These cylindrical waisted specimens of cortical bone were harvested from the middle diaphysis of three pairs of human femora. The porosity of these specimens was assessed by means of histology. Our study demonstrated that the longitudinal Young's and shear moduli of human femoral cortical bone were significantly (p<0.01) negatively correlated with the porosity of cortical bone. Conversely, the elastic properties in the transverse direction did not have statistically significant correlations with the porosity of cortical bone. As a result, the transverse elastic properties of cortical bone were less sensitive to changes in porosity than those in the longitudinal direction. Additionally, the anisotropic ratios of cortical bone elasticity were found to be significantly (p<0.01) negatively correlated with its porosity, indicating that cortical bone tended to become more isotropic when its porosity increased. These results may help a number of researchers develop more accurate micromechanics models of cortical bone.  相似文献   

3.
At mechanical equilibrium, articular cartilage is usually characterized as an isotropic elastic material with no interstitial fluid flow. In this study, the equilibrium properties (Young's modulus, aggregate modulus and Poisson's ratio) of bovine humeral, patellar and femoral cartilage specimens (n=26) were investigated using unconfined compression, confined compression, and indentation tests. Optical measurements of the Poisson's ratio of cartilage were also carried out. Mean values of the Young's modulus (assessed from the unconfined compression test) were 0.80+/-0.33, 0.57+/-0.17 and 0.31+/-0.18MPa and of the Poisson's ratio (assessed from the optical test) 0.15+/-0.06, 0.16+/-0.05 and 0.21+/-0.05 for humeral, patellar, and femoral cartilages, respectively. The indentation tests showed 30-79% (p<0.01) higher Young's modulus values than the unconfined compression tests. In indentation, values of the Young's modulus were independent of the indenter diameter only in the humeral cartilage. The mean values of the Poisson's ratio, obtained indirectly using the mathematical relation between the Young's modulus and the aggregate modulus in isotropic material, were 0.16+/-0.06, 0.21+/-0.05, and 0.26+/-0.08 for humeral, patellar, and femoral cartilages, respectively. We conclude that the values of the elastic parameters of the cartilage are dependent on the measurement technique in use. Based on the similar values of Poisson's ratios, as determined directly or indirectly, the equilibrium response of articular cartilage under unconfined and confined compression is satisfactorily described by the isotropic elastic model. However, values of the isotropic Young's modulus obtained from the in situ indentation tests are higher than those obtained from the in vitro unconfined or confined compression tests and may depend on the indenter size in use.  相似文献   

4.
The Hopkinson bar stress technique and a universal testing machine (Instron 1125) have been used to investigate the dynamic and static mechanical properties of cortical bone taken from a human femur respectively. We found that the average dynamic Young's modulus value (Ed = 19.9 GPa) to be 23% higher than the average static Young's modulus value (Ed = 16.2 GPa). Furthermore, the Poisson's ratio did not exhibit any significant variation for the two different types of loading. No difference was observed between the values of the dynamic Young's modulus in tension and those found in compression. A comparison was made of the results of this study with those found by other researchers using different techniques, such as ultrasonics, and it was found that they agree well with most of the results of previous studies. Finally, the viscosity for cortical bone found in this study correlates with viscosity reported by Tennyson et al. [Expl Mech. 12, 502-507 (1972)] for ten days post mortem age specimens.  相似文献   

5.
Acoustic microscopy (30-60 microm resolution) and nanoindentation (1-5 microm resolution) are techniques that can be used to evaluate the elastic properties of human bone at a microstructural level. The goals of the current study were (1) to measure and compare the Young's moduli of trabecular and cortical bone tissues from a common human donor, and (2) to compare the Young's moduli of bone tissue measured using acoustic microscopy to those measured using nanoindentation. The Young's modulus of cortical bone in the longitudinal direction was about 40% greater than (p<0.01) the Young's modulus in the transverse direction. The Young's modulus of trabecular bone tissue was slightly higher than the transverse Young's modulus of cortical bone, but substantially lower than the longitudinal Young's modulus of cortical bone. These findings were consistent for both measurement methods and suggest that elasticity of trabecular tissue is within the range of that of cortical bone tissue. The calculation of Young's modulus using nanoindentation assumes that the material is elastically isotropic. The current results, i.e., the average anisotropy ratio (E(L)/E(T)) for cortical bone determined by nanoindentation was similar to that determined by the acoustic microscope, suggest that this assumption does not limit nanoindentation as a technique for measurement of Young's modulus in anisotropic bone.  相似文献   

6.
Tendons are exposed to complex loading scenarios that can only be quantified by mathematical models, requiring a full knowledge of tendon mechanical properties. This study measured the anisotropic, nonlinear, elastic material properties of tendon. Previous studies have primarily used constant strain-rate tensile tests to determine elastic modulus in the fiber direction. Data for Poisson's ratio aligned with the fiber direction and all material properties transverse to the fiber direction are sparse. Additionally, it is not known whether quasi-static constant strain-rate tests represent equilibrium elastic tissue behavior. Incremental stress-relaxation and constant strain-rate tensile tests were performed on sheep flexor tendon samples aligned with the tendon fiber direction or transverse to the fiber direction to determine the anisotropic properties of toe-region modulus (E0), linear-region modulus (E), and Poisson's ratio (v). Among the modulus values calculated, only fiber-aligned linear-region modulus (E1) was found to be strain-rate dependent. The E1 calculated from the constant strain-rate tests were significantly greater than the value calculated from incremental stress-relaxation testing. Fiber-aligned toe-region modulus (E(1)0 = 10.5 +/- 4.7 MPa) and linear-region modulus (E1 = 34.0 +/- 15.5 MPa) were consistently 2 orders of magnitude greater than transverse moduli (E(2)0 = 0.055 +/- 0.044 MPa, E2 = 0.157 +/- 0.154 MPa). Poisson's ratio values were not found to be rate-dependent in either the fiber-aligned (v12 = 2.98 +/- 2.59, n = 24) or transverse (v21 = 0.488 +/- 0.653, n = 22) directions, and average Poisson's ratio values in the fiber-aligned direction were six times greater than in the transverse direction. The lack of strain-rate dependence of transverse properties demonstrates that slow constant strain-rate tests represent elastic properties in the transverse direction. However, the strain-rate dependence demonstrated by the fiber-aligned linear-region modulus suggests that incremental stress-relaxation tests are necessary to determine the equilibrium elastic properties of tendon, and may be more appropriate for determining the properties to be used in elastic mathematical models.  相似文献   

7.
The bone tissue of the canine mandible is elastically isotropic   总被引:3,自引:0,他引:3  
This paper reports experimental measurements which show that canine mandibular bone tissue is elastically isotropic. Earlier work has established that human, canine and bovine cortical bone tissue of the femur, tibia and skull are elastically anisotropic and therefore the reported isotropy of mandibular tissue was unexpected. The isotropic elastic moduli of the canine mandible are represented by a Young's modulus of 7.5 GPa and a Poisson's ratio of 0.4. Earlier work gave the three orthotropic Young's moduli of the cortical one of the canine femur as 12.8 GPa, 15.6 GPa and 20.1 GPa. The experimental technique employed is elastic wave propagation at ultrasonic frequencies.  相似文献   

8.
Articular cartilage has been shown to exhibit large transverse contractions when loaded in tension, suggesting the existence of large values for the Poisson's ratio. Previous studies have suggested that this effect is dependent on amplitude of applied strain, so that a single Poisson's ratio may not be sufficient to describe cartilage behavior. In this study, the Poisson's ratio (v), toe region modulus (Eo), and linear region modulus (E) of human patellar articular cartilage were calculated in simple tension tests from optical analysis of the two-dimensional strain fields at equilibrium. The Poisson's ratio was found to be independent of strain due to the absence of viscoelastic effects during testing. The Poisson's ratio was found to be significantly higher in the surface zone (1.87 +/- 1.11, p<0.01) than in the middle zone (0.62 +/- 0.23), with no significant correlation of v with age of the cartilage. In general, values for Poisson's ratio were greater than 0.5, suggesting cartilage behavior in tension deviates from isotropy. Reported values for the Poisson's ratio of cartilage in compression have been much lower than values measured here in tension, reflecting a mechanical contribution of the collagen fibers to anisotropy in tension but not compression. The toe-region modulus (Eo) was significantly higher in the surface zone (4.51 +/- 2.78 MPa, n=8) compared to the middle zone (2.51 +/- 1.93 MPa, n=10). In addition, the linear-region modulus (E) in the surface zone, but not middle zone (3.42 +/- 2.17 MPa, n=10), was found to correlate with age (R=0.97, p<0.02) with values of surface zone E equal to 23.92 +/- 12.29 MPa (n=5) for subjects under 70 yr of age, and 4.27 +/- 2.89 MPa (n=3) for subjects over 70 yr. Moduli values and trends with depth were consistent with previous studies of human and animal cartilage. From direct measures of two independent material properties, v and E, we calculated a shear modulus, G, which had not been previously reported for cartilage from tensile testing. Calculated values for surface zone G were 3.64 +/- 1.80 MPa for subjects under 70 yr old and 0.96 +/- 0.69 MPa for subjects over 70 yr old, and were significantly higher in the surface zone than in the middle zone (1.10 +/- 0.78 MPa). This study provides an intrinsic measure for the Poisson's ratio of articular cartilage and its dependence on depth which will be important in understanding the nonlinear tension-compression and anisotropic behaviors of articular cartilage.  相似文献   

9.
Substrates with tunable mechanical properties are crucial for the study of cellular processes, and polyacrylamide gels (PAGs) are frequently used in this context. Several experimental techniques have been proposed to obtain the mechanical properties of PAGs. However, the range of the considered Poisson's ratio values remains quite large and no attempt has been made to propose an analytical relationship allowing the estimation of PAG Young's modulus when both bis-acrylamide and acrylamide concentrations are known. In order to complete the actual knowledge on the mechanical properties of PAGs, we took benefit of our original method based on the micropipette aspiration technique (Boudou et al., J. Biomech. 2006) for characterizing gels made with concentrations in the range 0.02% < or =[Bis]< or =0.20% and 3% < or =[Acry]< or =10%. We found that the PAGs Young's modulus varies nonlinearly with the acrylamide amount. Moreover, our study validates the quasi-incompressibility hypothesis usually made in studies using PAGs (mean Poisson's ratio of 0.480+/-0.012). More generally, and in agreement with data published by other groups, we propose an original nonlinear mathematical relationship allowing the computation of Young's modulus of PAG for any given acrylamide and bis-acrylamide amounts taken in the range of values we considered.  相似文献   

10.
We studied the elastic properties of bone to analyze its mechanical behavior. The basic principles of ultrasonic methods are now well established for varying isotropic media, particularly in the field of biomedical engineering. However, little progress has been made in its application to anisotropic materials. This is largely due to the complex nature of wave propagation in these media. In the present study, the theory of elastic waves is essential because it relates the elastic moduli of a material to the velocity of propagation of these waves along arbitrary directions in a solid. Transducers are generally placed in contact with the samples which are often cubes with parallel faces that are difficult to prepare. The ultrasonic method used here is original, a rough preparation of the bone is sufficient and the sample is rotated. Moreover, to analyze heterogeneity of the structure we measure velocities in different points on the sample. The aim of the present study was to determine in vitro the anisotropic elastic properties of cortical bones. For this purpose, our method allowed measurement of longitudinal and transverse velocities (C(L) and C(T)) in longitudinal (fiber direction) and the radial directions (orthogonal to the fiber direction) of compact bones. Young's modulus E and Poisson's ratio nu, were then deduced from the velocities measured considering the compact bone as transversely isotropic or orthotropic. The results are in line with those of other methods.  相似文献   

11.
The anulus fibrosus (AF) of the intervertebral disc exhibits spatial variations in structure and composition that give rise to both anisotropy and inhomogeneity in its material behaviors in tension. In this study, the tensile moduli and Poisson's ratios were measured in samples of human AF along circumferential, axial, and radial directions at inner and outer sites. There was evidence of significant inhomogeneity in the linear-region circumferential tensile modulus (17.4+/-14.3 MPa versus 5.6+/-4.7 MPa, outer versus inner sites) and the Poisson's ratio v21 (0.67+/-0.22 versus 1.6+/-0.7, outer versus inner), but not in the axial modulus (0.8+/-0.9 MPa) or the Poisson's ratios V12 (1.8+/-1.4) or v13 (0.6+/-0.7). These properties were implemented in a linear an isotropic material model of the AF to determine a complete set of model properties and to predict material behaviors for the AF under idealized kinematic states. These predictions demonstrate that interactions between fiber populations in the multilamellae AF significantly contribute to the material behavior, suggesting that a model for th  相似文献   

12.
Articular cartilage is often characterized as an isotropic elastic material with no interstitial fluid flow during instantaneous and equilibrium conditions, and indentation testing commonly used to deduce material properties of Young's modulus and Poisson's ratio. Since only one elastic parameter can be deduced from a single indentation test, some other test method is often used to allow separate measurement of both parameters. In this study, a new method is introduced by which the two material parameters can be obtained using indentation tests alone, without requiring a secondary different type of test. This feature makes the method more suitable for testing small samples in situ. The method takes advantages of the finite layer effect. By indenting the sample twice with different-sized indenters, a nonlinear equation with the Poisson's ratio as the only unknown can be formed and Poisson's ratio obtained by solving the nonlinear equation. The method was validated by comparing the predicted Poisson's ratio for urethane rubber with the manufacturer's supplied value, and comparing the predicted Young's modulus for urethane rubber and an elastic foam material with modulii measured by unconfined compression. Anisotropic and nonhomogeneous finite-element (FE) models of the indentation were developed to aid in data interpretation. Applying the method to bovine patellar cartilage, the tissue Young's modulus was found to be 1.79 +/- 0.59 MPa in instantaneous response and 0.45 +/- 0.26 MPa in equilibrium, and the Poisson's ratio 0.503 +/- 0.028 and 0.463 +/- 0.073 in instantaneous and equilibrium, respectively. The equilibrium Poisson's ratio obtained in our work was substantially higher than those derived from biphasic indentation theory and those optically measured in an unconfined compression test. The finite element model results and examination of viscoelastic-biphasic models suggest this could be due to viscoelastic, inhomogeneity, and anisotropy effects.  相似文献   

13.
Damage accumulation plays a key role in weakening bones prior to complete fracture and in stimulating bone remodeling. The goal of this study was to characterize the degradation in the mechanical properties of cortical bone following a compressive overload. Longitudinally oriented, low-aspect ratio specimens (n=24) of bovine cortical bone were mechanically tested using an overload-hold-reload protocol. No modulus reductions greater than 5% were observed following overload magnitudes less than 0.73% strain. For each specimen, changes in strength and Poisson's ratio were greater (p=0.02) than that in modulus by 10.8- and 26.6-fold, respectively, indicating that, for the specimen configuration used in this study, longitudinal elastic modulus is one of the least sensitive properties to a compressive overload. Residual strains were also proportionately greater by 6.4-fold (p=0.01) in the transverse than axial direction. These results suggest that efforts to relate microcrack density and morphology to changes in compressive mechanical properties of cortical bone may benefit from considering alternative parameters to modulus reductions.  相似文献   

14.
The ultimate compressive strength and modulus of elasticity of femoral cortical bone from adult geese (Anser anser), were determined by sex and by quadrant by compressing small right circular cylinders which were 2.4 mm in height and 0.8 mm in diameter. The average ultimate compressive strength was 183 +/- 29 MPa. The average modulus of elasticity was 13.2 +/- 3.4 GPa. The bending strength and bending modulus of elasticity were determined by a three point bend test on rectangular prisms which had the approximate dimensions 0.75 mm X 0.75 mm X 25 mm. The average bending strength was 263 +/- 44 MPa while the average bending modulus was 19.6 +/- 3.1 GPa. The calcium content was determined by atomic absorption spectrophotometry and no correlation was found with the mechanical properties. The histology of the cortical bone was examined both quantitatively and qualitatively. A unique type of Haversian bone is described. Goose bone was found to be morphologically similar to adolescent human bone and to have mechanical properties similar to those of adult human bone.  相似文献   

15.
The ability to determine trabecular bone tissue elastic and failure properties has biological and clinical importance. To date, trabecular tissue yield strains remain unknown due to experimental difficulties, and elastic moduli studies have reported controversial results. We hypothesized that the elastic and tensile and compressive yield properties of trabecular tissue are similar to those of cortical tissue. Effective tissue modulus and yield strains were calibrated for cadaveric human femoral neck specimens taken from 11 donors, using a combination of apparent-level mechanical testing and specimen-specific, high-resolution, nonlinear finite element modeling. The trabecular tissue properties were then compared to measured elastic modulus and tensile yield strain of human femoral diaphyseal cortical bone specimens obtained from a similar cohort of 34 donors. Cortical tissue properties were obtained by statistically eliminating the effects of vascular porosity. Results indicated that mean elastic modulus was 10% lower (p<0.05) for the trabecular tissue (18.0+/-2.8 GPa) than for the cortical tissue (19.9+/-1.8 GPa), and the 0.2% offset tensile yield strain was 15% lower for the trabecular tissue (0.62+/-0.04% vs. 0.73+/-0.05%, p<0.001). The tensile-compressive yield strength asymmetry for the trabecular tissue, 0.62 on average, was similar to values reported in the literature for cortical bone. We conclude that while the elastic modulus and yield strains for trabecular tissue are just slightly lower than those of cortical tissue, because of the cumulative effect of these differences, tissue strength is about 25% greater for cortical bone.  相似文献   

16.
This work consists of the validation of a novel approach to estimate the local anisotropic elastic constants of the bone extracellular matrix using nanoindentation. For this purpose, nanoindentation on two planes of material symmetry were analyzed and the resulting longitudinal elastic moduli compared to the moduli measured with a macroscopic tensile test. A combined lathe and tensile system was designed that allows machining and testing of cylindrical microspecimens of approximately 4mm in length and 300 microm in diameter. Three bovine specimens were tested in tension and their outer geometry and porosity assessed by synchrotron radiation microtomography. Based on the results of the traction test and the precise outer geometry, an apparent longitudinal Young's modulus was calculated. Results between 20.3 and 27.6 GPa were found that match with previously reported values for bovine compact bone. The same specimens were then characterized by nanoindentation on a transverse and longitudinal plane. A longitudinal Young's modulus for the bone matrix was then derived using the numerical scheme proposed by Swadener and Pharr and the fabric-elasticity relationship by Zysset and Curnier. Based on the matrix modulus and a power law effective volume fraction, an apparent longitudinal Young's modulus was predicted for each microspecimen. This alternative approach provided values between 19.9 and 30.0 GPa, demonstrating differences between 2% and 13% to the values provided by the initial tensile test. This study therefore raises confidence in our nanoindentation protocol of the bone extracellular matrix and supports the underlying hypotheses used to extract the anisotropic elastic constants.  相似文献   

17.
Articular cartilage exhibits complex mechanical properties such as anisotropy, inhomogeneity and tension-compression nonlinearity. This study proposes and demonstrates that the application of compressive loading in the presence of osmotic swelling can be used to acquire a spectrum of incremental cartilage moduli (EYi) and Poisson's ratios (upsilon ij) from tension to compression. Furthermore, the anisotropy of the tissue can be characterized in both tension and compression by conducting these experiments along three mutually perpendicular loading directions: parallel to split-line (1-direction), perpendicular to split-line (2-direction) and along the depth direction (3-direction, perpendicular to articular surface), accounting for tissue inhomogeneity between the surface and deep layers in the latter direction. Tensile moduli were found to be strain-dependent while compressive moduli were nearly constant. The peak tensile (+) Young's moduli in 0.15M NaCl were E+Y1=3.1+/-2.3, E+Y2=1.3+/-0.3, E+Y3(Surface)=0.65+/-0.29 and E+Y3(Deep)=2.1+/-1.2 MPa. The corresponding compressive (-) Young's moduli were E-Y1=0.23+/-0.07, E-Y2=0.22+/-0.07, E-Y3(Surface)=0.18+/-0.07 and E-Y3(Deep)=0.35+/-0.11 MPa. Peak tensile Poisson's ratios were upsilon+12=0.22+/-0.06, upsilon+21=0.13+/-0.07, upsilon+31(Surface)=0.10+/-0.03 and upsilon+31(Deep)=0.20+/-0.05 while compressive Poisson's ratios were upsilon-12=0.027+/-0.012, upsilon-21=0.017+/-0.07, upsilon-31(Surface)=0.034+/-0.009 and upsilon-31(Deep)=0.065+/-0.024. Similar measurements were also performed at 0.015 M and 2 M NaCl, showing strong variations with ionic strength. Results indicate that (a) a smooth transition occurs in the stress-strain and modulus-strain responses between the tensile and compressive regimes, and (b) cartilage exhibits orthotropic symmetry within the framework of tension-compression nonlinearity. The strain-softening behavior of cartilage (the initial decrease in EYi with increasing compressive strain) can be interpreted in the context of osmotic swelling and tension-compression nonlinearity.  相似文献   

18.
Relaxation Young's modulus of cortical bone was investigated for two different directions with respect to the longitudinal axis of bone (bone axis, BA): the modulus parallel (P) and normal (N) to the BA. The relaxation modulus was analyzed by fitting to the empirical equation previously proposed for cortical bones, i.e., a linear combination of two Kohlraush-Williams-Watts (KWW) functions (Iyo et al., 2003. Biorheology, submitted): E(t)=E0 (A1 exp[-(t/tau1)beta]+(1-A1) exp[-(t/tau2)gamma]), [0 < A1, beta, gamma < 1], where E0 is the initial modulus value E0. Tau1 and tau2(>tau1) are characteristic times of the relaxation, A1 is the fractional contribution of the fast relaxation (KWW1 process) to the whole relaxation process, and beta and gamma are parameters describing the shape of the relaxation modulus. In both P and N samples, the relaxation modulus was described well by the empirical equation. The KWW1 process of a P sample almost completely coincided with that of an N sample. In the slow process (KWW2 process), there was a difference between the relaxation modulus of a P sample and that of an N sample. The results indicate that the KWW1 process in the empirical equation represents the relaxation in the collagen matrix in bone and that the KWW2 process is related to a higher-order structure of bone that is responsible for the anisotropic mechanical properties of bone.  相似文献   

19.
A hydrogel with potential applications in the role of a cushion form replacement joint bearing surface material has been investigated. The material properties are required for further development and design studies and have not previously been quantified. Creep indentation experiments were therefore performed on samples of the hydrogel. The biphasic model developed by Mow and co-workers (Mak et al., 1987; Mow et al., 1989a) was used to curve-fit the experimental data to theoretical solutions in order to extract the three intrinsic biphasic material properties of the hydrogel (aggregate modulus, HA, Poisson's ratio, Vs, and permeability, k). Ranges of material properties were determined: aggregate modulus was calculated to be between 18.4 and 27.5 MPa, Poisson's ratio 0.0-0.307, and permeability 0.012-7.27 x 10(-17) m4/Ns. The hydrogel thus had a higher aggregate modulus than values published for natural normal articular cartilage, the Poisson's ratios were similar to articular cartilage, and finally the hydrogel was found to be less permeable than articular cartilage. The determination of these values will facilitate further numerical analysis of the stress distribution in a cushion form replacement joint.  相似文献   

20.
Errors induced by off-axis measurement of the elastic properties of bone   总被引:1,自引:0,他引:1  
Misalignment between the axes of measurement and the material symmetry axes of bone causes error in anisotropic elastic property measurements. Measurements of Poisson's ratio were strongly affected by misalignment errors. The mean errors in the measured Young's moduli were 9.5 and 1.3 percent for cancellous and cortical bone, respectively, at a misalignment angle of 10 degrees. Mean errors of 1.1 and 5.0 percent in the measured shear moduli for cancellous and cortical bone, respectively, were found at a misalignment angle of 10 degrees. Although, cancellous bone tissue was assumed to have orthotropic elastic symmetry, the possibility of the greater symmetry of transverse isotropy was investigated. When the nine orthotropic elastic constants were forced to approximate the five transverse isotropic elastic constants, errors of over 60 percent were introduced. Therefore, it was concluded that cancellous bone is truly orthotropic and not transversely isotropic. A similar but less strong result for cortical bone tissue was obtained.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏