首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
It has become evident that the mystery of life will not be deciphered just by decoding its blueprint, the genetic code. In the life and biomedical sciences, research efforts are now shifting from pure gene analysis to the analysis of all biomolecules involved in the machinery of life. One area of these postgenomic research fields is proteomics. Although proteomics, which basically encompasses the analysis of proteins, is not a new concept, it is far from being a research field that can rely on routine and large-scale analyses. At the time the term proteomics was coined, a gold-rush mentality was created, promising vast and quick riches (i.e., solutions to the immensely complex questions of life and disease). Predictably, the reality has been quite different. The complexity of proteomes and the wide variations in the abundances and chemical properties of their constituents has rendered the use of systematic analytical approaches only partially successful, and biologically meaningful results have been slow to arrive. However, to learn more about how cells and, hence, life works, it is essential to understand the proteins and their complex interactions in their native environment. This is why proteomics will be an important part of the biomedical sciences for the foreseeable future. Therefore, any advances in providing the tools that make protein analysis a more routine and large-scale business, ideally using automated and rapid analytical procedures, are highly sought after. This review will provide some basics, thoughts and ideas on the exploitation of matrix-assisted laser desorption/ ionization in biological mass spectrometry – one of the most commonly used analytical tools in proteomics – for high-throughput analyses.  相似文献   

2.
Proline-containing peptides of the X-proline type are cleaved by the dipeptidase prolidase. The classical method of prolidase assay relied on the colorimetric estimation of the liberated proline with ninhydrin using acidic media and heat. This method, however, gave inconsistent results due to the nonspecificity of the ninhydrin color reaction. We report here a method for the detection of the liberated proline using matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry. Human sera were incubated with a mixture containing the dipeptide glycyl-proline in Tris-HCl supplemented with manganese at 37 degrees C for 24h. The samples were precipitated with trifluoroacetic acid and centrifuged. An aliquot of the supernatant was mixed with an equal volume of ferulic acid solution. An aliquot from this mixture was spotted on a stainless steel mass spectrometry grid and analyzed using MALDI-TOF mass spectrometry. The activity of the enzyme was determined by the complete disappearance of the glycyl-proline peak with the concomitant appearance of the proline peak and can be expressed in terms of the ratio of the area beneath the proline to the area beneath the glycyl-proline peak. Subjects homozygous for prolidase deficiency had a ratio ranging from 0.006 to 0.04 while obligatory heterozygotes had a ratio ranging from around 1.1 to 2.4. Normal subjects had ratios ranging from 9 to 239. Using this method we have unambiguously identified subjects with homozygous or heterozygous prolidase deficiency. In addition to the advantage of rapid sample preparation time, this method is highly specific, reproducible, and sensitive.  相似文献   

3.
A method is described for the quantitative determination of peptides using matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry. Known limitations imposed by crystal heterogeneity, peptide ionization differences, data handling, and protein quantification with MALDI-TOF mass spectrometry are addressed in this method with a "seed crystal" protocol for analyte-matrix formation, the use of internal protein standards, and a software package called maldi_quant. The seed crystal protocol, a new variation of the fast-evaporation method, minimizes crystal heterogeneity and allows for consistent collection of protein spectra. The software maldi_quant permits rapid and automated analysis of peak intensity data, normalization of peak intensities to internal standards, and peak intensity deconvolution and estimation for vicinal peaks. Using insulin proteins in a background of other unrelated peptides, this method shows an overall coefficient of variance of 4.4%, and a quantitative working range of 0.58-37.5 ng bovine insulin per spot. Coupling of this methodology to powerful analytical procedures such as immunoprecipitation is likely to lead to the rapid and reliable quantification of biologically relevant proteins and their closely related variants.  相似文献   

4.
Although modern MS has facilitated the advent of metabolomics, some natural products such as carotenoids are not readily compatible to detection by MS. In the present article, we describe how matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI/TOF-MS) can be utilized to acquire mass spectra of carotenoids effectively. The procedure is sensitive (pmole range), reduces 'spot to spot' variation and provides high mass accuracy, thus aiding identification. The technique has been applied in vivo to the analysis of carotenoids in isolated plant cells and in vitro to three applications: (i) to show compatibility with purification methods such as LC, TLC and HPLC; (ii) for the rapid identification and quantification (by isotope dilution) of carotenoids present in crude extracts from plant tissues and whole cells; (iii) simultaneous semi-quantitative determination of carotenoids metabolites (m/z values) in crude plant extracts. Multivariate analysis of the recorded m/z values shows the effectiveness of the procedure in distinguishing genotypes from each other. In addition, the utility of the technique has been demonstrated on two mutant tomato populations, to determine alterations in carotenoid content, and a comparison made with traditional HPLC-photodiode array analysis. These data show that MALDI/TOF-MS can be used to rapidly profile, identify and quantify plant carotenoids reproducibly, as well as detecting other metabolites (m/z) in complex biological systems.  相似文献   

5.
6.
7.
与传统的微生物鉴定技术相比,基质辅助激光解吸电离飞行时间质谱(matrix-assisted laser desorption ionization time-of-flight mass spectrometry, MALDI-TOF MS)是一种准确、可靠和快速的鉴定和分型的技术。本文通过检索近年来国内外相关研究论文,总结最新的研究进展,发现MALDI-TOF MS在临床病原微生物、食源性微生物以及环境微生物等鉴定中有较大的优势,加快了微生物鉴定的进程,同时探索该技术在新领域的最新进展和面临的挑战,以期为我国基质辅助激光解吸电离飞行时间质谱技术的发展提供参考。  相似文献   

8.
9.
A technique for sequencing oligonucleotides using matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry is described. The series of coupling failure species are extracted from the dimethoxytrityl-on, full-length oligonucleotide in crude synthetic material using C18 stationary-phase cartridges. These concentrated failure species can be easily detected by MALDI-TOF, which determines the mass difference between spectral ions to identify a particular base. The solid-phase extraction step greatly enhances ion signals and mass resolution, and sequencing information is generally obtained from the 5' end up to the first three to four nucleotides at the 3' end. Complete sequence can be generated in conjunction with snake venom phosphodiesterase digestion of purified material. This method eliminates difficulties associated with other mass spectrometric sequencing techniques involving oligonucleotide length; structure; and sugar, base, and backbone modifications. Examples of sequencing a 17-mer composed primarily of 2'-O-methylribonucleotides and a single nonnucleosidic linker and a mixed sugar backbone 51-mer with 2'-O-methylribonucleotides and a homopolymer tail are reported in this study.  相似文献   

10.
邵锦  万喆  李若瑜  余进 《菌物学报》2019,38(8):1277-1286
基质辅助激光解析电离飞行时间质谱(matrix-assisted laser desorption/ionization time-of-flight mass spectrometry,MALDI-TOF MS)是近年来新兴的微生物检测技术,通过核糖体蛋白分析实现对真菌快速、准确鉴定。本文针对MALDI-TOF MS用于致病真菌鉴定、分类、体外抗真菌药物敏感性检测以及临床微生物样本直接检测等方面作一综述。  相似文献   

11.
A capillary electrophoretic method (CE) for characterizing PEGylated human parathyroid hormone 1-34 (PTH) with matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) is described. CE was used to optimize the PEGylation of PTH through control of the reaction pH and the molar ratio of reactants with the advantages of minimal sample consumption and high separation capacity. The mono-PEGylated PTH (mono-PEG-PTH) was isolated and then digested with endoproteinase Lys-C. Resistance to Lys-C digestion on the PEGylation sites in the mono-PEG-PTH resulted in patterns of CE electropherograms different from that of the native PTH, and the PEGylation sites were assigned accordingly. The extent of positional isomers present in the mono-PEG-PTH was also determined by quantifying PEGylated fragments in the same CE electropherogram. In conclusion, the CE analysis of the Lys-C-digested sample allowed for simultaneous analysis of the PEGylation site and the extent of positional isomers in the mono-PEG-PTH. The results were confirmed by MALDI-TOF MS. This method will be applicable for characterizing PEGylation of other therapeutic peptides.  相似文献   

12.
The analysis of urinary acylglycines is an important biochemical tool for the diagnosis of many organic acidemias and mitochondrial fatty acid β-oxidation defects. A new rapid analytical method has been developed for quantification of acylglycines in urine by liquid chromatography coupled with tandem mass spectrometry (LC–MS/MS). The method requires a simple sample preparation avoiding derivatization. It has high sensitivity, specificity, and throughput capability, and it requires minimal instrument maintenance. The use of chromatographic separation allows us to identify and quantify isomeric compounds that cannot be solved by appropriate multiple reaction monitoring (MRM) transitions. Urinary concentrations of the different acylglycines were determined using deuterated internal standards. The reference interval for the various metabolites was established using 120 healthy controls. The diagnostic usefulness of the method was demonstrated in three patients with propionic acidemia (PA), one patient with isovaleric acidemia (IVA), two patients with beta ketothiolase deficiency (BKTD), one patient with short branched chain amino acid deficiency (SBCAD), four patients with medium chain acyl-coenzyme A dehydrogenase deficiency (MCADD), one patient with isobutyryl-coenzyme A dehydrogenase deficiency (IBDHD), and one patient with multiple acyl-coenzyme A dehydrogenase deficiency (MADD).  相似文献   

13.
14.
Activated factor XIII (FXIIIa) catalyzes the formation of γ-glutamyl-ε-lysyl cross-links within the fibrin blood clot network. Although several cross-linking targets have been identified, the characteristic features that define FXIIIa substrate specificity are not well understood. To learn more about how FXIIIa selects its targets, a matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI–TOF MS)-based assay was developed that could directly follow the consumption of a glutamine-containing substrate and the formation of a cross-linked product with glycine ethylester. This FXIIIa kinetic assay is no longer reliant on a secondary coupled reaction, on substrate labeling, or on detecting only the final deacylation portion of the transglutaminase reaction. With the MALDI–TOF MS assay, glutamine-containing peptides derived from α2-antiplasmin, Staphylococcus aureus fibronectin binding protein A, and thrombin-activatable fibrinolysis inhibitor were examined directly. Results suggest that the FXIIIa active site surface responds to changes in substrate residues following the reactive glutamine. The P−1 substrate position is sensitive to charge character, and the P−2 and P−3 substrate positions are sensitive to the broad FXIIIa substrate specificity pockets. The more distant P−8 to P−11 region serves as a secondary substrate anchoring point. New knowledge on FXIIIa specificity may be used to design better substrates or inhibitors of this transglutaminase.  相似文献   

15.
The attachment protein or G protein of the A2 strain of human respiratory syncytial virus (RSV) was digested with trypsin and the resultant peptides separated by reverse-phase high-performance liquid chromatography (HPLC). One tryptic peptide produced a mass by matrix-assisted laser desorption/ionization (MALDI) time-of-flight (TOF) mass spectrometry (MS) corresponding to residues 152-187 with the four Cys residues of the ectodomain (residues 173, 176, 182, and 186) in disulfide linkage and absence of glycosylation. Sub-digestion of this tryptic peptide with pepsin and thermolysin produced peptides consistent with disulfide bonds between Cys173 and Cys186 and between Cys176 and Cys182. Analysis of ions produced by post-source decay of a peptic peptide during MALDI-TOF-MS revealed fragmentation of peptide bonds with minimal fission of an inter-chain disulfide bond. Ions produced by this unprecedented MALDI-induced post-source fragmentation corroborated the existence of the disulfide arrangement deduced from mass analysis of proteolysis products. These findings indicate that the ectodomain of the G protein has a non-glycosylated subdomain containing a "cystine noose."  相似文献   

16.
Matrix-assisted laser desorption/ionization quadrupole ion trap time-of-flight mass spectrometry (MALDI-QIT-TOF MS) was used to analyze three pyridylamino (PA)-fucosyloligosaccharides isolated from human milk: lacto-N-fucopentaose (LNFP) I [Fucα1-2Galβ1-3GlcNAcβ1-3Galβ1-4Glc-PA], LNFP II [Galβ1-3(Fucα1-4)GlcNAcβ1-3Galβ1-4Glc-PA], and LNFP III [Galβ1-4(Fucα1-3)GlcNAcβ1-3Galβ1-4Glc-PA]. These oligosaccharides are linkage isomers. MALDI-QIT-TOF MS provides MSn spectra, which we used to characterize these PA-oligosaccharides. MS/MS/MS analysis of the non-reducing end tri-saccharide ions generated by MS/MS was able to distinguish these oligosaccharide isomers. The MALDI-QIT-TOF MS is a very convenient and rapid method, therefore, it would be useful for high throughput structural analyses of various types of pyridylaminated oligosaccharide isomers.  相似文献   

17.
To evaluate matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-ToF MS) as a tool for rapid identification of common clinical bacterial isolates, we analyzed 25 carefully selected isolates of pathogenic Escherichia coli (E. coli) and additional Enterobacteriaceae members. Organisms were prepared according to clinical microbiological protocols and analyzed with minimal additional processing. Spectra were reproducible from preparation to preparation and comprised 40-100 peaks primarily representing intracellular proteins with masses up to 25 kDa. Spectra of 14 genetically diverse bacteremic isolates of E. coli were compared with isolates representing other genera within the Enterobacteriaceae family. Using a new spectrum comparison algorithm, E. coli isolates were closely related to each other and were readily distinguishable from other Enterobacteriaceae, including Salmonella and Shigella. Presently, the methodology permits the analysis of 40 unknown isolates per hour per instrument. These results suggest that MALDI-ToF MS offers a rapid and reliable approach for performing phyloproteomics i.e., identification of unknown bacterial isolates based on similarities within protein biomarker databases.  相似文献   

18.
It has become evident that the mystery of life will not be deciphered just by decoding its blueprint, the genetic code. In the life and biomedical sciences, research efforts are now shifting from pure gene analysis to the analysis of all biomolecules involved in the machinery of life. One area of these postgenomic research fields is proteomics. Although proteomics, which basically encompasses the analysis of proteins, is not a new concept, it is far from being a research field that can rely on routine and large-scale analyses. At the time the term proteomics was coined, a gold-rush mentality was created, promising vast and quick riches (i.e., solutions to the immensely complex questions of life and disease). Predictably, the reality has been quite different. The complexity of proteomes and the wide variations in the abundances and chemical properties of their constituents has rendered the use of systematic analytical approaches only partially successful, and biologically meaningful results have been slow to arrive. However, to learn more about how cells and, hence, life works, it is essential to understand the proteins and their complex interactions in their native environment. This is why proteomics will be an important part of the biomedical sciences for the foreseeable future. Therefore, any advances in providing the tools that make protein analysis a more routine and large-scale business, ideally using automated and rapid analytical procedures, are highly sought after. This review will provide some basics, thoughts and ideas on the exploitation of matrix-assisted laser desorption/ ionization in biological mass spectrometry - one of the most commonly used analytical tools in proteomics - for high-throughput analyses.  相似文献   

19.
Quantitative analysis of free fatty acids was achieved using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) with a meso-tetrakis porphyrin matrix. Cesium acetate was employed as a cationizing agent. The MALDI signal was reproducible and dominated by cesiated cesium carboxylates [RCOOCs + Cs]+. The addition of two Cs ions resulted in a mass shift of 264.8 Da for each fatty acid and greatly reduced background peaks. A linear relationship between fatty acid concentration and corresponding fatty acid to internal standard peak intensity ratio was observed for three representative fatty acids analyzed across a concentration range from 4.40 to 150 microM, with correlation coefficients between 0.986 and 0.987. The application of this method was demonstrated with the analysis of free fatty acids in nonfasted and fasted rat plasmas. A total of eight free fatty acids (14:0, 16:0, 16:1, 17:0, 18:0, 18:1, 18:2, and 20:4) were detected. The relative peak height ratios of the fatty acids to the internal standard allow quantitative measurements of the free fatty acids. It was shown that the levels of free fatty acids were higher in fasted rats than in rats in a nonfasted state. This method is simple, sensitive, and fast. Thus, it provides an appealing tool for the analysis of free fatty acids or other low-molecular weight compounds during drug discovery and/or development.  相似文献   

20.
N-Acetylneuraminic acid (a sialic acid) occurs mainly as a terminal substituent of oligosaccharides of glycoconjugates. Derivatives of neuraminic acid occur widely, substituted in the amino and hydroxy side chains, as well in the C-9 carbon skeleton. These derivatives are responsible for specific functions of sialic acids during cell-cell, cell-substrate, or cell-virus interactions. The study of O-acetylated neuraminic acids is difficult, because only small amounts are extractable from natural sources and they are generally unstable to acids and bases. We report a new method for the rapid analysis of O-acetylated neuraminic acids, using a combination of reversed phase HPLC and MALDI-TOF mass spectrometry. A mixture of neuraminic acids from bovine submaxillary gland mucins was analysed, as well as neuraminic acids variously substituted in the amino and hydroxy side chains with acetyl and glycolyl groups, respectively. © 1998 Rapid Science Ltd  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号