1.
A high-throughput ultrafiltration method with a direct injection assay has been developed to determine unbound concentrations of a high-protein binding compound, an alpha(v)beta(3) bone integrin antagonist (I), in human plasma for a clinical pharmacokinetic study. The 96-well MultiScreen filter plate with Ultracel-PPB membrane was evaluated for the separation of unbound from protein-bound compound I by ultrafiltration. The sample preparation was automated using a Packard MultiPROBE II EX liquid handling system to transfer the plasma samples to the 96-well PPB plate for centrifugation and to prepare ultrafiltrate samples for analysis. Using on-line extraction with a column-switching setup for sample clean-up and separation, the ultrafiltrate samples were directly injected onto a reversed-phase HPLC system and analyzed using a mass spectrometer interfaced with an electrospray ionization (ESI) source in the positive ionization mode (LC/ESI-MS/MS). The performance of the ultrafiltration using Ultracel-PPB 96-well plate for unbound I analysis was evaluated and optimized with respect to sample volume, centrifugation temperature, speed and time, and the relationship of the well positions of the PPB plate versus filtrate volumes and concentrations. The assay intraday accuracy and precision were between 93.9 and 104.8 and <7.3% (CV), respectively. The linear range of the calibration curve for the assay was 0.1-500 ng/mL on a Finnigan TSQ Quantum LC/ESI-MS/MS system. Evaluation and validation of the unbound plasma assay demonstrated it to be rapid, sensitive and reproducible.  相似文献   

2.
A specific and sensitive liquid chromatography-electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) method has been developed for the determination of 1alpha-hydroxyvitamin D(3) (1alphaOHD(3)) in rat plasma. A new ferrocene-based Cookson-type reagent, 4-ferrocenylmethyl-1,2,4-triazoline-3,5-dione (FMTAD), designed and synthesized to be highly sensitive to vitamin D analogs in ESI, considerably improved the detection limit with 250 fg (359 amol)/injection. 1alphaOHD(3) in rat plasma was extracted with acetonitrile and then purified using Oasis HLB 96-well plates. After the precolumn derivatization with FMTAD, samples were subjected to LC/ESI-MS/MS employing a column-switching system. This method achieved a lower limit of quantitation of 5 pg from 0.1-mL plasma aliquots and 200-fold sensitivity of that without derivatization. The calibration curve (0.05-15 ng/mL) exhibited acceptable linearity (r>0.9966), intraassay precision ranged from 3.8 to 9.6%, interassay precision ranged from 3.0 to 17.0%, and accuracy was within 81.4-112.0%. This FMTAD derivatization method is considered very useful for determination of vitamin D analogs in ESI and applicable for biological samples.  相似文献   

3.
Plasma phospholipids metabolic profile of chronic glomerulonephritis was investigated using high performance liquid chromatography/mass spectrometry (LC/MS) and principal component analysis. The plasma samples of 18 patients with chronic glomerulonephritis, 17 patients with chronic renal failure (CRF) without renal replacement therapy and 18 healthy persons were collected and analyzed. It was found that combination of the LC/MS technique with PCA can be successfully applied to phospholipid profile analysis. The results showed that primary chronic glomerulonephritis and CRF had phospholipids metabolic abnormality. Nineteen phospholipid species were identified as possible biomarkers in plasma samples of chronic glomerulonephritis and chronic renal failure. Moreover, the identification of the molecular structure of the potential phospholipid markers was obtained by ESI-MS/MS experiment. It suggests that phospholipids can be used as potential biomarkers on the progress of primary chronic glomerulonephritis.  相似文献   

4.
A sample treatment procedure and high-sensitive liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) method for quantitative determination of fexofenadine in human plasma was developed for a microdose clinical trial with a cold drug, i.e., a non-radioisotope-labeled drug. Fexofenadine and terfenadine, as internal standard, were extracted from plasma samples using a 96-well solid-phase extraction plate (Oasis HLB). Quantitation was performed on an ACQUITY UPLC system and an API 5000 mass spectrometer by multiple reaction monitoring. Chromatographic separation was achieved on an XBridge C18 column (100 mm x 2.1 mm i.d., particle size 3.5 microm) using acetonitrile/2 mM ammonium acetate (91:9, v/v) as the mobile phase at a flow rate of 0.6 ml/min. The analytical method was validated in accordance with the FDA guideline for validation of bioanalytical methods. The calibration curve was linear in the range of 10-1000 pg/ml using 200 microl of plasma. Analytical method validation for the clinical dose, for which the calibration curve was linear in the range of 1-500 ng/ml using 20 microl of plasma, was also conducted. Each method was successfully applied for making determinations in plasma using LC/ESI-MS/MS after administration of a microdose (100 microg solution) and a clinical dose (60 mg dose) in eight healthy volunteers.  相似文献   

5.
Homocysteine is an endogenous sulphydryl aminoacid irreversibly catabolized by transsulfuration to cysteine or remethylated to methionine. Increased plasma levels of homocysteine are an independent risk factor for atherosclerosis and cardiovascular disease. Accurate and reliable quantification of this amino acid in plasma samples is essential in clinical practice to explore the presence of a hyperhomocysteinemia, for instance after an ischemic event, or to control a possible adjunctive risk factor in patients at higher risk. In this review, LC–ESI-MS/MS methods are discussed and compared with other analytical methods for plasma homocysteine. LC–ESI-MS/MS is a technique combining the physicochemical separation of liquid chromatography with the analysis of mass spectrometry. It is based on stable-isotope dilution and possesses inherent accuracy and precision. Quantitative analysis is achieved by using commercially available homocystine-d8 as an internal standard. Taking advantage of the high sensitivity and specificity, approaches involving LC–ESI-MS/MS require less laborious sample preparation, no derivatization and produce reliable results.  相似文献   

6.
A reversed-phase high-performance liquid chromatographic assay for the simultaneous determination of phenytoin and fosphenytoin, a prodrug for phenytoin, in human plasma and plasma ultrafiltrate is described. For plasma, the method involves simple extraction of drugs with diethyl ether and evaporation of solvent, followed by injection of the reconstituted sample onto a reversed-phase C18 column. Plasma ultrafiltrate is injected directly into the HPLC column. Compounds are eluted using an ion-pair mobile phase containing 20% acetonitrile. The eluent is monitored by UV absorbance at 210 nm. The fosphenytoin standard curves are linear in the concentration range 0.4 to 400 μg/ml for plasma and 0.03 to 80 μg/ml for ultrafiltrate. Phenytoin standard curves are linear from 0.08 to 40 μg/ml for plasma and from 0.02 to 5.0 μg/ml for ultrafiltrate. No interferences with the assay procedure were found in drug-free blank plasma or plasma ultrafiltrate. Relative standard deviation for replicate plasma or ultrafiltrate samples was less than 5% at concentrations above the limit of quantitation for both within- and between-run calculations.  相似文献   

7.
Carboplatin is a platinum analogue that is used in a number of chemotherapeutic regimens for solid tumors, such as lung and ovarian carcinomas. Most often characterization of carboplatin's pharmacokinetic properties is based on measurement of platinum, rather than intact carboplatin. We have developed a sensitive LC-MS method for the determination of intact carboplatin in plasma ultrafiltrate and in tumor tissue. Carboplatin was extracted from rat plasma ultrafiltrate and tumor samples using solid-phase extraction cartridges and analyzed using reversed-phase chromatography with positive electrospray ionization followed by mass spectrometric detection. Using 50 microliter of plasma ultrafiltrate or 140 microliter of tumor homogenate supernatant, the extraction afforded a recovery of 58.7 and 45.8% for plasma and tumor, respectively. The mobile phase was 5% acetonitrile in 0.5% acetic acid at 0.2 ml/min that yielded a retention time of carboplatin of 2.2 min. The method has been validated at carboplatin plasma ultrafiltrate concentrations from 0.07 to 2.5 microgram/ml, and from 0.03 to 1.3 microgram/ml in tumor homogenates. The main advantages of this method compared with earlier methods are the ability to measure intact carboplatin in a sensitive and specific manner.  相似文献   

8.
For the determination of the HIV protease inhibitors lopinavir and ritonavir in human plasma, plasma ultrafiltrate, and peripheral blood mononuclear cells (PBMCs) a highly sensitive and selective method has been developed, validated, and applied to samples of a healthy volunteer. BD Vacutainer CPT and Amicon Centriplus centrifugal filter devices were used for separation of PBMCs and for ultrafiltrate generation, respectively. After liquid/liquid-extraction extracts were chromatographed isocratically within 6 min on a Jupiter Proteo column. The drugs were quantified using 2H5-saquinavir as internal standard and electrospray tandem mass spectrometry in the selected reaction monitoring mode. Limits of quantification for both analytes were 4.0 ng/mL in plasma, 0.2 ng/mL in ultrafiltrate, and 0.1 ng/cell pellet (approximately 3 x 10(6) cells) in PBMCs. The calibration ranges were linear over more than three logs with an over-all accuracy varying between 98.7% and 111.5% and an over-all precision ranging from 6.2% to 14.0% (SD batch-to-batch). After a regular oral dose of Kaletra (400 mg lopinavir, 100 mg ritonavir) analyte concentrations were detectable over a full dosing interval in plasma, ultrafiltrate, and PBMCs. The method is well suited for monitoring of free and total plasma, and intracellular lopinavir/ritonavir concentrations in samples from clinical trials.  相似文献   

9.
Measurement of oxalate in human plasma ultrafiltrate by ion chromatography   总被引:2,自引:0,他引:2  
An improved ion chromatographic method for the measurement of oxalate in human plasma ultrafiltrate is described. Ultrafiltration was carried out using an appropriate device and procedure. Centrifugation of 0.5 ml heparin plasma at 4°C for 50 min yielded water-clear ultrafiltrate in amounts allowing replicate measurements of oxalate. The specificity of the method was confirmed. The recovery of oxalate added to plasma was approximately 80%, whereas dilution of plasma, and of an oxalate-containing salt solution, resulted in falsely high values; the mechanism(s) underlying this phenomenon are insufficiently understood at present. The intra-assay of the method was assessed and from replicates of a pool plasma, the inter-assay precision from ten measurements of the same plasma on different days; the observed ranges of oxalate were 1.32-1.56 (mean 1.42) and 1.42-1.64 (mean 1.53) μmol/l, respectively. In plasma ultrafiltrate of a limited number of healthy volunteers the range of oxalate was 1.81-2.50 μmol/l, thus permitting renal oxalate handling to be studied.  相似文献   

10.
Plasma renin activity (PRA) is an essential analytical tool for screening and diagnosis of secondary forms of hypertension. Typically, PRA is measured by competitive radioimmunoassay, but there are significant drawbacks to this technique including non-specificity, long analysis times, narrow calibration range, and the requirement for radionucleotides. In this paper, we report a method for plasma renin activity determination by immuno-MALDI mass spectrometry detection. This method overcomes the issues of non-specificity and long analytical times present with RIA, and does not require the use of radionucleotides. As an initial methodological evaluation, plasma renin activity results obtained by radioimmunoassay, LC/ESI-MS/MS, and immuno-MALDI on 64 samples from an outpatient primary aldosteronism screening program have been compared. A strong correlation was found between immuno-MALDI and radioimmunoassay (R2 = 0.9412, 62/64 within the 95% CI of the Bland-Altman plot), and iMALDI and LC/ESI-MS/MS (R2 = 0.9471, 62/64 within the 95% CI of the Bland-Altman plot). Technical replicates showed a 4.8% CV, while inter- and intra-day replicates showed CVs of 17.3% and 17.2% respectively. We have developed an assay capable of measuring PRA without the use of radionucleotides. This immuno-MALDI approach affords the specificity of MS while avoiding the long analytical run times and technical problems associated with HPLC. With the use of robotic sample preparation to optimize precision, this assay should be adaptable to clinical environments.  相似文献   

11.
Lipid profiling of human plasma by liquid chromatography-electrospray ionization coupled to mass spectrometry (LC–ESI-MS) is being used to identify biomarkers of health, disease, and treatment efficacy. However, there is no consensus on the choice of anticoagulant to perform and compare lipidomic measurements. This study assessed the effect of the anticoagulants citrate, EDTA, and heparin, on eight synthetic and 80 plasma lipids, and compared lipidomic data among anticoagulants. Lipid extraction was affected distinctively by the anticoagulant of choice likely due to the different physico-chemical properties among anticoagulants. Peak areas of seventy endogenous lipids showed significant differences between citrate–heparin and EDTA–heparin comparisons similar to those observed for synthetic lipids. Only ten endogenous lipid species showed comparable peak areas among the three anticoagulants. Correction by a structurally related internal standard only partly eliminated differences among anticoagulants (ANOVA, P value <0.001). However, comparisons among anticoagulants were possible for most endogenous lipids after correction of peak areas by the sum of areas of its lipid class. Our observations indicate that the choice of anticoagulant distinctively impact the peak response of most lipid species by LC–ESI-MS. Lipidomic data from plasma obtained with different anticoagulants should address differences in matrix effects and extraction procedures since ion strength, plasma pH, and different physicochemical properties among anticoagulants influence lipid extraction and LC–ESI-MS analysis.  相似文献   

12.
A direct plasma injection method has been developed for the rapid analysis of drugs in biological fluids. A new generation restricted access media column specifically designed to accommodate direct injection of plasma and other fluids is utilized for on-line HPLC–ESI-MS analysis. For rapid analysis the on-line extraction column is linked to a HPLC–ESI-MS system. Good results are obtained for the quantitation of CP-93 393 and deuterated internal standard over the range of 10–1000 ng/ml. The lower limit of detection for the assay was 58 pg injected on column. Accuracy and precision values are 9.0% or better over the entire range of the assay. In addition, more than 200 injections (100 μl) were performed per column with unattended, automated analysis.  相似文献   

13.
A liquid chromatographic procedure using UV detection was coupled with ultrafiltration for the quantitation of free phenylbutazone in bovine plasma, in the range of 20 ng/ml to 2.0 μg/ml. Whole plasma samples (0.5 to 1 ml) were placed in a 2-ml centrifugal concentrator with a molecular-mass cut-off membrane of 10 000 and centrifuged at 4500 g for 2 h at 4°C using a fixed angle rotor. The ultrafiltrate was transferred to an LC vial with a 200-μl insert and 100 μl was injected into an LC system. The chromatographic system used a C18 reversed-phase column connected to a UV detector set at 264 nm. The mobile phase was 0.2 M sodium phosphate buffer (pH 7)–methanol (1:1). Recoveries of phenylbutazone from protein-free plasma water fortified at levels of 20 ng/ml to 2 μg/ml ranged from 91 to 93%, with relative standard deviations (R.S.D.s) ranging from 1 to 4%. The concentration of incurred non-protein bound phenylbutazone obtained from a cow intravenously dosed twice with 2 g phenylbutazone, 8 h apart, was 111, 26 and 11 ng/ml for 2, 72 and 104 h post first phenylbutazone dose, respectively.  相似文献   

14.
Sirolimus is a widely used immunosuppressant that requires therapeutic drug monitoring (TDM). We optimized a preanalytical procedure that allows for the accurate quantiation of sirolimus in whole blood by LC/ESI-MS/MS with minimal matrix effects. Sirolimus is highly lipophilic, and solvents containing greater than 50% methanol were required to maintain sirolimus recovery. The final pretreatment procedure developed consists of a zinc sulfate protein precipitation, an extraction using octadecyl silyl-silica gel for eliminating water-soluble and hydrophilic compounds, and HybridSPE cartridge treatment to eliminate phospholipids. Using this procedure prior to LC/ESI-MS/MS led to the accurate and reproducible quantitation of sirolimus in human whole blood. The linear range of detection was 0.5-50 ng/mL, a range appropriate for TDM, and the method demonstrated good repeatability and intermediate precision within this quantitative range. In order to investigate the quantitative performance of this method, we compared it to two commercially available sirolimus immunoassays and our previously reported LC/ESI-MS/MS method. The immunoassays gave consistently greater values for the sirolimus concentration, and this may be related to antibody cross-reactivity with sirolimus metabolites and/or other matrix effects. Although our procedure is too long to support real-time TDM for outpatients, it can serve as reference method to assess the performance of other analytical methods that are currently available or may be developed in the future.  相似文献   

15.
Liquid chromatography electrospray ionization tandem mass spectrometry (LC/ESI-MS/ MS) and high-performance liquid chromatography (HPLC) methods have been used to identify and quantify the major taxoids from extracts of Taxus chinensis cell cultures. Chromatography was carried out on a reverse phase C18 column with isocratic-mode elution. By analytically comparing LC/ESI-MS/MS of the extracts with that of the available reference substances and literature, six taxoids were identified as taxuyunnanine C (Tc, 1), yunnanxane (2), 2alpha,5alpha10beta-triacetoxy-14beta-propionyloxytaxa-4(20),11-diene (3), 2alpha,5alpha, 10beta-triacetoxy-14beta-(2-methyl)butyryloxytaxa-4(20),11-diene (4), taxol (5), and baccatin III (B III, 6), respectively. Among them, 2, 3 and 4 were assigned in the absence of the corresponding reference substances, and 3 and 4 were detected in this cell line for the first time. The identification was validated by NMR spectra. The precise quantification of 1 and 5 was made using HPLC. The limit of detection (LOD), 0.5 microg/ml for 5, 1.5 microg/ml for 1, and the linearity and accuracy of the quantitative method were evaluated, indicating a wide linear range and satisfactory accuracy. The amounts of other identified taxoids were calculated on the basis of comparison of the absolute response factors of similar structural substances. The proposed method provides a rapid, conventional and reliable tool to characterize and study cell lines for elucidating the taxane biosynthesis.  相似文献   

16.
We have adapted the Gamma-flo automated radioimmunoassay system to analyze for cyclic 3',5'-AMP in plasma. Direct analysis of plasma samples was not possible due to an interfering substance(s) in plasma. Evidence suggested that the interfering substance is human serum albumin. An efficient, relatively simple method was developed by applying the acetylation procedure to ultrafiltrates of plasma samples and utilizing the Gamma-flo system for rapid radioimmunoassay (50 samples per hour) of cyclic AMP content in the filtrates. Coefficient of variation within assays averaged 3% and interassay coefficient of variation was 4.7%. Recovery of cyclic AMP from plasma into the ultrafiltrate ranged from 93 to 100%. Increments of cyclic AMP added to plasma were recovered linearly up to approximately 60 pmol/ml, the highest concentration tested.  相似文献   

17.
Achieving a rapid microbiological diagnosis is crucial for decreasing morbidity and mortality of patients with a bloodstream infection, as it leads to the administration of an appropriate empiric antimicrobial therapy. Molecular methods may offer a rapid alternative to conventional microbiological diagnosis involving blood culture. In this study, the performance of a new technology that uses broad-spectrum PCR coupled with mass spectrometry (PCR/ESI-MS) was evaluated for the detection of microorganisms directly from whole blood. A total of 247 whole blood samples and paired blood cultures were prospectively obtained from 175 patients with a suspicion of sepsis. Both sample types were analyzed using the PCR/ESI-MS technology, and the results were compared with those obtained by conventional identification methods. The overall agreement between conventional methods and PCR/ESI-MS performed in blood culture aliquots was 94.2% with 96.8% sensitivity and 98.5% specificity for the molecular method. When comparing conventional methods with PCR/ESI-MS performed in whole blood specimens, the overall agreement was 77.1% with 50% sensitivity and 93.8% specificity for the molecular method. Interestingly, the PCR/ESI-MS technology led to the additional identification of 13 pathogens that were not found by conventional methods. Using the PCR/ESI-MS technology the microbiological diagnosis of bloodstream infections could be anticipated in about half of the patients in our setting, including a small but significant proportion of patients newly diagnosed. Thus, this promising technology could be very useful for the rapid diagnosis of sepsis in combination with traditional methods.  相似文献   

18.
A rapid high-performance liquid chromatography (HPLC) method was developed for determination of metformin, an oral antidiabetic agent, in plasma. Sample preparation entailed a 30-min centrifugation of plasma through a micron filter with direct injection of the protein-free ultrafiltrate into an HPLC system consisting of a cation-exchange extraction column (7.5×4.6 mm), a column switching valve, and a cation-exchange analytical column (250×4.6 mm). The eluent was monitored at 232 nm. Metformin was well resolved at a retention time of about 5 min. There was less than 2% loss of metformin during ultrafiltration and good linearity was established from 0.10 to 40 mg/l of metformin hydrochloride. The lower limit of quantitation was about 0.05 mg/l, at which concentration the signal-to-noise was above 10. The intra- and inter-assay coefficients of variation at plasma concentrations of metformin hydrochloride between 0.25 and 25 mg/l were typically 0.8–1.4% and 3.5–6.4%, respectively. This method offers a rapid sample preparation time and achieves excellent sensitivity without resorting to extraction and evaporation techniques.  相似文献   

19.
A novel and relatively simple analytical method for the separation, characterisation and semi-quantitation of phospholipids (PLs) from extracts of complex biological samples has been developed. This methodology allows PL extracts from cells and tissues to be analysed by liquid chromatography (LC) coupled to electrospray ionisation mass spectrometry (ESI-MS). Complex mixtures of PLs were separated on a high-performance liquid chromatography (HPLC) system using 0.5% ammonium hydroxide in methanol/water/hexane/formate mixture with UV detection at 205 nm. Identification and structural characterisation of molecular species were carried out utilising ESI-MS and MS/MS in the negative ion mode.The abnormal accumulation of PLs (phospholipidosis) was induced in male Sprague-Dawley rats by administration of the cationic amphiphilic drug (CAD), amiodarone. Analysis of the PL profile of liver and lung tissues, lymphocytes and serum from treated rats was carried out using this analytical procedure (LC-ESI/MS/MS). Differences in PL profiles between treated and untreated animals were highlighted by principal component analysis (PCA). This led to the selection of a potential metabolic marker of phospholipidosis (PLD) identified as a lyso-bis-phosphatidic acid (LBPA) derivative, also known as bis(monoglycero)phosphate (BMP). This PL was absent in control animals but was present in quantifiable amounts in all samples from amiodarone-treated rats.  相似文献   

20.
Vinorelbine is a semi-synthetic vinca alkaloid with demonstrated high activities against various types of advanced cancer. To support a clinical pharmacokinetic study, a simple, rapid and sensitive method to determine vinorelbine in human plasma was developed using reversed phase liquid chromatography (LC) coupled with electrospray ionization mass spectrometry/mass spectrometry (ESI-MS/MS). Vinorelbine and vinblastine (the internal standard) were extracted from human plasma by one-step liquid-liquid extraction (LLE) with methyl-t-butyl ether. The chromatographic separation was achieved on a Spursil polar-modified C(18) column (50 mm×2.1 mm, 3 μm, Dikma Technologies) with an isocratic mobile phase of a 75:25 (v/v) acetonitrile-4 mmol/L ammonium formate (pH 3.0) mixture at a flow-rate of 0.4 mL/min. The MS/MS detection was performed in the positive ion multiple reaction monitoring (MRM) mode by monitoring the precursor→product ion transitions at m/z 779.4→122.0 and m/z 811.3→224.2 for vinorelbine and the internal standard, respectively. The assay was validated in the range 0.1-200 ng/mL (r>0.997), the lowest level of this range being the lower limit of quantification (LLOQ) based on 50 μL of plasma. The intra- and inter-day precisions were within 6.0%, while the accuracy was within ±4.7% of nominal values. Detection and quantification of both analytes within 2 min make this method suitable for high-throughput analyses. The method was successfully applied to evaluate the systemic pharmacokinetics of vinorelbine after a 20-min intravenous infusion of 25 mg/m(2) of vinorelbine to patients with metastatic breast cancer.  相似文献   