首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
In order to verify the reproducibility, precision, and robustness of the optical immunosensor River Analyser (RIANA), we investigated two common statistical methods to evaluate the limit of detection (LOD) and the limit of quantification (LOQ). Therefore, we performed a simultaneous multi-analyte calibration with atrazine, bisphenol A, and estrone in Milli-Q water. Using an automated biosensor, it was possible for the first time to achieve a LOD below 0.020 microg L(-1) using a common statistically based method without sample pre-treatment and pre-concentration for each of the analytes in a simultaneous multi-analyte calibration. This biosensor setup shows values comparable to those obtained by more classical analytical methods. Based on this calibration, we measured spiked and un-spiked real water samples with complex matrices (samples from different water bodies, from ground water sources, and tap water samples). The comparison between our River Analyser and common analytical methods (like GC-MS and HPLC-DAD) shows overall comparable values for all three analytes. Furthermore, a calibration of isoproturon (IPU) (in single analyte mode) resulted in a LOD of 0.016 microg L(-1), and a LOQ of 0.091 microg L(-1). In compliance with guidelines of the Association of Analytical Communities International (AOAC), six out of nine recovery rates (recovery rate: measured concentration divided by real concentration in percent) for three surface water samples with different matrices (spiked and un-spiked) could be obtained between 70 and 120% (recovery rates between 70 and 120%, as demanded by the guidelines of the AOAC International). The reproducibility was checked by measuring replica of each sample within independent repetitions. Robustness could be demonstrated by long-term stability tests of the biosensor surface. These studies show that the biosensor used offers the necessary reproducibility, precision, and robustness required for an analytical method.  相似文献   

2.
A biosensor system based on total internal reflectance fluorescence (TIRF) was used to discriminate a mixture of the triazines atrazine and simazine. Only cross-reactive antibodies were available for these two analytes. The biosensor is fully automated and can be regenerated allowing several hundreds of measurements without any user input. Even a remote control for online monitoring in the field is possible. The multivariate calibration of the sensor signal was performed using artificial neural networks, as the relationship between the sensor signals and the concentration of the analytes is highly non-linear. For the development of a multi-analyte immunoassay consisting of two polyclonal antibodies with cross-reactivity to atrazine and simazine and different derivatives immobilised on the transducer surface, the binding characteristics between these substances like binding capacity and cross-reactivity were characterised. The examination of three different measurement procedures showed that a two-step measurement using only one antibody per step allows a quantification of both analytes in a mixture with limits of detection of 0.2 microg/l for atrazine and 0.3 microg/l for simazine. The biosensor is suitable for online monitoring in the field and remote control is possible.  相似文献   

3.
Han IS  Han MH  Kim J  Lew S  Lee YJ  Horkay F  Magda JJ 《Biomacromolecules》2002,3(6):1271-1275
A new type of biosensor is proposed that combines the recognition properties of "intelligent" hydrogels with the sensitivity and reliability of microfabricated pressure transducers. In the proposed device, analyte-induced changes in the osmotic swelling pressure of an environmentally responsive hydrogel are measured by confining it within a small implantable enclosure between a rigid semipermeable membrane and the diaphragm of a miniature pressure transducer. Proof-of-principle tests of this device were performed in vitro using pH-sensitive hydrogels, with osmotic deswelling data for the same hydrogels used as a benchmark for comparison. The swelling pressure of the hydrogel was accurately determined from osmotic deswelling measurements against reservoirs of known osmotic stress. Values of swelling pressure vs salt concentration measured with a preliminary version of the sensor agree well with osmotic deswelling results. Through modification of the hydrogel with various enzymes or pendant binding moieties, the sensor has the potential to detect a wide range of biological analytes with good specificity.  相似文献   

4.
Based on the requirements of biomolecular interaction analysis on direct optical transducers, a streptavidin surface is examined. A general protocol was developed allowing the immobilization of biotinylated compounds using the rife biotin-streptavidin system. This type of surface modification can be applied to all biosensors using glass surfaces as sensor devices. Reflectometric interference spectroscopy (RIfS), a label-free, direct optical method was used to demonstrate the quality of the transducer surfaces. The surface modification is based on an aminofunctionalized polyethylene glycol layer covalently bound to the silica surface of the transducer and shows very little nonspecific binding. Biotin molecules can be easily coupled on such layers. Streptavidin followed by a biotinylated estrone derivative was immobilized by incubation of the biotinylated transducer surface. For the streptavidin layer we obtained interference signals corresponding to a protein monolayer. Finally, using a surface prepared as described above, biomolecular interaction experiments with an antibody against estrone were carried out to show the quality of the transducer surface. With RIfS all of the affinity-based surface modifications can be detected online and time resolved.  相似文献   

5.
In this work we present the development of a multi-analyte immunosensor for the determination of follitropin, human chorionic gonadotropin and prolactin in human serum. The immunosensor is based on plastic capillaries. According to the methodology, discrete areas of the internal capillary surface are coated with different antibodies, which are highly specific for each one of the analytes to be determined. The sample that will be analyzed along with a mixture of analyte-specific biotinylated antibodies is introduced into the capillary. The coated and the detection antibodies react with different epitopes of the analytes in the sample to form a 'sandwich'. The detection is based on reaction of the immobilized biotinylated antibody with streptavidin labeled with R-phycoerythrin. The fluorescent areas formed were quantified by scanning the capillary with a light beam of appropriate wavelength. A light sensor placed at the end of the capillary detects the emitted photons, that are trapped and waveguided into the capillary walls. The multi-analyte immunosensor assays were characterized by high specificity and short analysis time. In addition, the results obtained by the multi-analyte optical capillary immunosensor were comparable to those obtained by immunofluorimetric assays performed in microtitration wells. Potential applications of the proposed immunosensor include determination of several analyte panels in a broad spectrum of disciplines such as endocrinology, hematology, and oncology.  相似文献   

6.
This article describes the continuous on-line monitoring of a dechlorination process by a novel attenuated total reflection-Fourier transform infrared (ATR-FTIR) sensor. This optical sensor was developed to measure noninvasively part-per-million (ppm) concentrations of trichloroethylene (TCE), tetrachloroethylene (PCE), and carbon tetrachloride (CT) in the aqueous effluent of a fixed-bed dechlorinating bioreactor, without any prior sample preparation. The sensor was based on an ATR internal reflection element (IRE) coated with an extracting hydrophobic polymer, which prevented water molecules from interacting with the infrared (IR) radiation. The selective diffusion of chlorinated compound molecules from aqueous solution into the polymer made possible their detection by the IR beam. With the exclusion of water the detection limits were lowered, and measurements in the low ppm level became possible. The best extracting polymer was polyisobutylene (PIB) in the form of a 5.8-microm thick film, which afforded a detection limit of 2, 3, and 2. 5 mg/L (ppm) for TCE, PCE, and CT, respectively. Values of the enrichment factors between the polymer coating and the water matrix of these chloro-organics were determined experimentally and were compared individually with predictions obtained from the slopes of absorbance/concentration curves for the three analytes. Before coupling the ATR-FTIR sensor to the dechlorinating bioreactor, preliminary spectra of the chlorinated compounds were acquired on a laboratory scale configuration in stop-flow and flow-through closed-loop modes. In this way, it was possible to study the behavior and direct response of the optical sensor to any arbitrary concentration change of the analytes. Subsequently, the bioreactor was monitored with the infrared sensor coupled permanently to it. The sensor tracked the progression of the analytes' spectra over time without perturbing the dechlorinating process. To calibrate the ATR-FTIR sensor, a total of 13 standard mixtures of TCE, PCE and CT at concentrations ranging from 0 to 60 ppm were selected according to a closed symmetrical experimental design derived from a 3(2) full-factorial design. The above range of concentrations chosen for calibration reflected typical values during normal bioreactor operation. Several partial least squares (PLS) calibration models were generated to resolve overlapping absorption bands. The standard error of prediction (SEP) ranged between 0.6 and 1 ppm, with a relative standard error of prediction (RSEP) between 3 and 6% for the three analytes. The accuracy of this ATR-FTIR sensor was checked against gas chromatography (GC) measurements of the chlorocompounds in the bioreactor effluents. The results demonstrate the efficiency of this new sensor for routine continuous on-line monitoring of the dechlorinating bioreactor. This strategy is promising for bioprocess control and optimization.  相似文献   

7.
Frequent measurement of below ground water levels at multiple locations is an important component of many wetland ecosystem studies. These measurements, however, are usually time consuming, labor intensive, and expensive. This paper describes a water-level sensor that is inexpensive and easy to construct. The sensor is placed below the expected low water level in a shallow well and, when connected to a datalogger, uses a pressure transducer to detect groundwater or surface water elevations. Details of pressure transducer theory, sensor construction, calibration, and examples of field installations are presented. Although the transducers must be individually calibrated, the sensors have a linear response to changing water levels (r 2 .999). Measurement errors resulting from temperature fluctuations are shown to be about 4 cm over a 35°C temperature range, but are minimal when the sensors are installed in groundwater wells where temperatures are less variable. Greater accuracy may be obtained by incorporating water temperature data into the initial calibration (0.14 cm error over a 35C temperature range). Examples of the utility of these sensors in studies of groundwater/surface water interactions and the effects of water level fluctuations on tree growth are provided.  相似文献   

8.
Molecularly imprinted polymers (MIPs) are gaining great interest as tailor-made recognition materials for the development of biomimetic sensors. Various approaches have been adopted to interface MIPs with different transducers, including the use of pre-made imprinted particles and the in situ preparation of thin polymer layers directly on transducer surfaces. In this work we functionalized quartz crystal microbalance (QCM) sensor crystals by coating the sensing surfaces with pre-made molecularly imprinted nanoparticles. The nanoparticles were immobilized on the QCM transducers by physical entrapment in a thin poly(ethylene terephthalate) (PET) layer that was spin-coated on the transducer surface. By controlling the deposition conditions, it was possible to gain a high nanoparticle loading in a stable PET layer, allowing the recognition sites in nanoparticles to be easily accessed by the test analytes. In this work, different sensor surfaces were studied by micro-profilometry and atomic force microscopy and the functionality was evaluated using quartz crystal microbalance with dissipation (QCM-D). The molecular recognition capability of the sensors were also confirmed using radioligand binding analysis by testing their response to the presence of the test compounds, (R)- and (S)-propranolol in aqueous buffer.  相似文献   

9.
Biosensors     
Biosensors are analytical devices that respond selectively to analytes in an appropriate sample and convert their concentration into an electrical signal via a combination of a biological recognition system and an electrochemical, optical or other transducer. Such devices will find application in medicine, agriculture, environmental monitoring and the bioprocessing industries. The last few years have seen great advances in the design of sensor architectures, the marriage of biological systems with monolithic silicon and optical technologies, the development of effective electron-transfer systems and the configuration of direct immunosensors. Recent progress in these areas has already led to the introduction of new-generation biosensors into the competitive diagnostics market place.  相似文献   

10.
In this paper, surface plasmon resonance curves of an optical fiber-based sensor were investigated. From an experimental and theoretical perspective, the response curves were analyzed and discussed. Precisely, such curves were calculated by modeling the analyte/metallic layer interface using a multilayer system, including the effects of roughness. Then, the experimental response curves observed in solutions with different refractive indices were compared to the simulated curves. Good agreement was obtained with respect to the resonance peak location and the shape of the curves. Consequently, these results enabled us to predict the ideal functioning conditions of the sensor, i.e., the working parameters corresponding to the best sensitivities of detection.  相似文献   

11.
An evanescent field fibre optic sensor was employed for detecting and monitoring aerobiological pathogen contamination in hospital environment. Measurements of methicillin-resistant Staphylococcus aureus (MRSA) and Streptococcus pneumoniae colonies were detected in 6 and 13 h, respectively, faster than those obtained by means of conventional techniques. All of the bacteria growth phases were clearly time resolved by means of the optical sensor. The 0.33 cm2 sensitive surface area fibre optic transducer also exhibited reproducibility, was of easy construction and low cost, which greatly enhances its potential and usefulness.  相似文献   

12.
A screening of 27 fungal strains for degradation of the phenylurea herbicide isoproturon was performed and yielded 15 strains capable of converting the herbicide to polar metabolites. The zygomycete fungus Cunninghamella elegans strain JS/2 isolated from an agricultural soil converted isoproturon to several known hydroxylated metabolites. In addition, unknown metabolites were produced in minor amounts. Inducible degradation was indicated by comparing resting cells pregrown with or without isoproturon. This shows that strain JS/2 is capable of partially degrading isoproturon and that one or more of the enzymes involved are inducible upon isoproturon exposure.  相似文献   

13.
Acoustic sensors that exploit resonating quartz crystals to directly detect the binding of an analyte to a receptor are finding increasing utility in the quantification of clinically relevant analytes. We have developed a novel acoustic detection technology, which we term resonant acoustic profiling (RAP). This technology builds on the fundamental basics of the "quartz crystal microbalance" or "QCM" with several key additional features including two- or four-channel automated sample delivery, in-line referencing and microfluidic sensor 'cassettes' that are pre-coated with easy-to-use surface chemistries. Example applications are described for the quantification of myoglobin concentration and its interaction kinetics, and for the ranking of enzyme-cofactor specificities.  相似文献   

14.
A SPR-based immunosensor for the detection of isoproturon   总被引:1,自引:0,他引:1  
The proof of principle of a reusable surface plasmon resonance (SPR)-based immunosensor for the monitoring of isoproturon (IPU), a selective and systemic herbicide, is presented. The detecting rat monoclonal anti-isoproturon antibody (mAb IOC 7E1) was reversibly immobilized through the use of a capture mouse anti-rat (kappa-chain) monoclonal antibody (mAb TIB 172), which was covalently immobilized on the sensor chip surface. Such strategy features a controlled binding of the captured detecting antibody as well as facilitates the surface regeneration. The capture of the anti-IPU mAb by the antibody (TIB 172) coated sensor surface could be carried out up to 120 times (immobilization/regeneration cycles) without any evidence of activity loss. With a high test midpoint and a low associated SPR signal, the direct detection format was shown to be unsuitable for the routine analysis of isoproturon. However, the limit of detection (LOD) could be easily enhanced by using a strategy based on a surface competition assay, which improved all immunosensor parameters. Moreover, the sensitivity and working range of the indirect format were found to be dependent on the surface density of the anti-IPU mAb IOC 7E1. As expected for competitive formats, the lowest surface coverage (0.5 ng/mm(2)) allowed a lower detection of the herbicide isoproturon with a calculated LOD of 0.1 microg/l, an IC(50) (50% inhibition) of 5.3+/-0.6 microg/l, and a working range (20-80% inhibition) of 1.3-16.3 microg/l.  相似文献   

15.
Engineering receptors and antibodies for biosensors   总被引:2,自引:0,他引:2  
Biosensor sensitivity and selectivity depend essentially on the properties of the biorecognition elements to be used for analyte binding. Two principally different applications are considered, (1) effects monitoring with biological components as targets for bioeffective substances, among them endocrine disruptors; and (2) immunochemical analysis employing antibodies as binding proteins for a wide variety of analytes such as pesticides. Genetic engineering provides an elegant way not only for providing unlimited amounts of biorecognition molecules but also for the alteration of existing properties and the supplementation with additional functions. Instrumental applications were carried out with the optical sensor BIAcore. The first example deals with the characterization of receptors. For this purpose, the human estrogen receptor alpha was used. Binding studies were carried out with natural as well as xenoestrogens. An equilibrium dissociation constant K(d) of 2.3x10(-10) (M) was derived for 17beta-estradiol. A competition assay was performed with a bovine serum albumin (BSA)-17beta-estradiol conjugate, immobilized at the optical sensor surface, and the free estrogen. The signals obtained represent estradiol equivalents. This format was transferred to a microplate-based enzyme-linked receptor assay. It reached a detection limit of 0.02 microg l(-1) 17beta-estradiol and proved suitable for the detection of natural and synthetic estrogens as well as xenoestrogens in field studies. The second example is targeted at kinetic and affinity measurements of recombinant antibody fragments derived from antibody libraries with s-triazine selectivities. Different strategies for the synthesis of antibody fragment libraries, followed by the selection of specific antibody variants, were examined. An antibody library was derived from a set of B cells. Chain shuffling of the heavy and light chains provided the best binders. An enzyme linked immunosorbent assay (ELISA) was achieved for atrazine with an IC(50) of 0.9 microg l(-1) and a detection limit of 0.2 microg l(-1). The close relations between the optimization of recombinant antibodies by evolutionary strategies and genetic algorithms are considered.  相似文献   

16.
Herbicides are largely used to control weed growth in wheat production. However, the application of some kind of herbicides usually aggravates the damage caused by low temperature, and is also a very common adversity during the early growth stages of wheat. In this study, we pre-treated wheat seedlings with the herbicide chemicals of isoproturon, fluroxypyr and fenoxaprop-P-ethyl, respectively and then exposed the plants to low temperature stress with different time intervals. The herbicides, especially isoproturon, significantly increased the negative effects of low temperature on electron transport rate, chlorophyll content, cell membrane stability as well as growth of wheat plants. Furthermore, the foliar application of ascorbic acid (AsA) decreased relative electric conductivity, reduced the content of malondialdehyde, and reduced the production rate of reactive oxygen species, these were in line with elevated activities of superoxide dismutase, catalase and peroxidase under the combined stress of isoproturon and low temperature, indicating that AsA effectively mitigated the sever oxidative stress induced by the combined stresses. Thus, some of the herbicides such as isoproturon are suggested to be very carefully used before the possibility of low temperature events. In case low temperature stress occurs after using of isoproturon, AsA could be used to partially alleviate the damage by the combined stress of isoproturon and low temperature in wheat production.  相似文献   

17.
Microplates with integrated optical oxygen sensors are a new tool to study metabolic rates and enzyme activities. Precise measurements are possible only if oxygen exchange between the sample and the environment is known. In this study we quantify gas exchange in plastic microplates. Dissolved oxygen was detected using either an oxygen-sensitive film fixed at the bottom of each well or a needle-type sensor. The diffusion of oxygen into wells sealed with different foils, paraffin oil, and paraffin wax, respectively, was quantified. Although foil covers showed the lowest oxygen permeability, they include an inevitable gas phase between sample and sealing and are difficult to manage. The use of oil was found to be critical due to the extensive shaking caused by movement of the plates during measurements in microplate readers. Thus, paraffin wax was the choice material because it avoids convection of the sample and is easy to handle. Furthermore, without shaking, significant gradients in pO2 levels within a single well of a polystyrene microplate covered with paraffin oil were detected with the needle-type sensor. Higher pO2 levels were obtained near the surface of the sample as well as near the wall of the well. A significant diffusion of oxygen through the plastic plate material was found using plates based on polystyrene. Thus, the location of a sensor element within the well has an effect on the measured pO2 level. Using a sensor film fixed on the bottom of a well or using a dissolved pO2-sensitive indicator results in pO2 offset and in apparently lower respiration rates or enzyme activities. Oxygen diffusion through a polystyrene microplate was simulated for measurements without convection--that is, for samples without oxygen diffusion through the cover and for unshaken measurements using permeable sealings. This mathematical model allows for calculation of the correct kinetic parameters.  相似文献   

18.
A surface immobilized optical protein sensor has been utilized to detect Interleukin-8 (IL-8) protein, an oral cancer marker, and can reach limit of detection (LOD) at 1.1pM in buffer without using enzymatic amplification. Only after applying enzymatic amplification to increase the signal level by a few orders of magnitude, ELISA can reach the LOD of 1pM level. We then develop the confocal optics based sensor for further reducing the optical noise and can extend the LOD of the surface immobilized optical protein sensor two orders in magnitude. These improvements have allowed us to detect IL-8 protein at 4.0fM in buffer. In addition, these sensitive LODs were achieved without the use of enzymatic signal amplification, such that the simplified protocol can further facilitate the development of point-of-care devices. The ultra sensitive optical protein sensor presented in this paper has a wide number of applications in disease diagnoses. Measurements for detecting biomarkers in clinical sample are much more challenging than the measurements in buffer, due to high background noise contributed by large collections of non-target molecules. We used clinical saliva samples to validate the functionality of the optical protein sensor. Clinical detection of disease-specific biomarkers in saliva offers a non-invasive, alternative approach to using blood or urine. Currently, the main challenge of using saliva as a diagnostic fluid is its inherently low concentration of biomarkers. We compare the measurements of 40 saliva samples; half from oral cancer patients and half from a control group. The data measured by the optical protein sensor is compared with the traditional Enzyme-Linked Immunosorbant Assay (ELISA) values to validate the accuracy of our system. These positive results enable us to proceed to using confocal optical protein sensor to detect other biomarkers, which have much lower concentrations.  相似文献   

19.
Immobilized reagent phase flow injection analysis can be configured as discrete reagent cells upstream of the sensor element or as an integral reagent/transduction system (flow injection analysis-biosensor). The former approach has attracted greater attention because several assays can be assembled with greater versatility in reagent column units employing a single sensor, than can be co-immobilized on the surface of a transducer.  相似文献   

20.
The analysis of carbaryl in natural water samples was accomplished using a portable immunosensor based on surface plasmon resonance (SPR) technology. The assay was based on a binding inhibition immunoassay format with the analyte derivative covalently immobilized on the sensor surface. An alkanethiol self-assembled monolayer (SAM) was formed onto the gold-coated sensor surface to allow the reusability of the same sensing surface during 220 regeneration cycles. Reproducibility was evaluated by performing three independent assays in triplicate on 3 different days. The batch-assay variability was also calculated using three different gold-coated sensor surfaces. The intra- and inter-day relative standard deviation were 8.6 and 15.3%, respectively, whilst a variation of 7.4% in assay sensitivity was obtained by employing different sensor chips. The lowest detection limit, calculated as the concentration providing a 10% decrease of the blank signal, was of 1.38 microg L(-1). Matrix effects were also evaluated in different water types, showing I50 values (carbaryl concentrations that produced a 50% decrease of the blank signal) within the range of carbaryl standard curves in distilled water (2.78-3.55 microg L(-1)). The carbaryl immunoassay performance was validated with respect to conventional high-performance liquid chromatography-mass spectrometry (HPLC-MS). The correlation between methods was in good agreement (r2 = 0.998, 0.999 and 0.999) for the three types of natural water samples tested. A complete assay cycle, including regeneration, is accomplished in 20 min. All measurements were carried out with the SPR sensor system (beta-SPR) commercialised by the company SENSIA, SL (Spain). The small size and low-time of response of the beta-SPR platform would allow its utilization in real contaminated locations.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号