首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Ceramic hydroxyapatite high-performance liquid chromatography was examined as a chromatographic method by which complexes of whole membrane proteins and sodium dodecyl sulfate could be analyzed. The chromatographic conditions were optimized using the erythrocyte membrane as a model. Whole proteins, including membrane proteins larger than 100 kDa, were eluted as sharp peaks from the column and separated well from each other under optimum conditions. This method gave better resolution of protein-SDS complexes than other chromatographic methods reported so far. The sodium dodecyl sulfate complexes of 24 well characterized proteins were analyzed by this method and their retention times were examined. The positive correlation of the retention time with log (molecular mass) and log sigma (hydrophobicity of amino acids) but not with the isoelectric point, was observed. Based on these results, the mechanism underlying the interaction of protein-SDS complexes with ceramic hydroxyapatite was discussed.  相似文献   

2.
The beneficial effect of high mass accuracy in mass spectrometry is especially pronounced when using less specific enzymes as the number of theoretically possible peptides increases dramatically without any cleavage specificity defined. Together with a preceding chromatographic separation, high-resolution mass spectrometers such as the MALDI-LTQ-Orbitrap are therefore well suited for the analysis of protein digests with less specific enzymes. A combination with fast, automated, and informative MALDI-TOF/TOF analysis has already been shown to yield increased total peptide and protein identifications. Here, a simple method for nLC separation and subsequent alternating spotting on two targets for both a MALDI-LTQ-Orbitrap and a MALDI-TOF/TOF instrument is introduced. This allows for simultaneous measurements on both instruments and subsequent combination of both data sets by an in-house written software tool. The performance of this procedure was evaluated using a mixture of four standard proteins digested with elastase. Three replicate runs were examined concerning repeatability and the total information received from both instruments. A cytosolic extract of C. glutamicum was used to demonstrate the applicability to more complex samples. Database search results showed that an additional 32.3% of identified peptides were found using combined data sets in comparison to MALDI-TOF/TOF data sets.  相似文献   

3.
Advancement in proteomics research relies on the development of new, innovative tools for identifying and characterizing proteins. Here, we describe a protocol for analyzing peptides and proteins on a chromatographic timescale by coupling nanoflow reverse-phase (RP) liquid chromatography (LC) to electron-transfer dissociation (ETD) mass spectrometry. For this protocol, proteins can be proteolytically digested before ETD analysis, although digestion is not necessary for all applications. Proteins 相似文献   

4.
A chromatographic method based on "split-peak" behavior was described for the determination of the coefficient of mass transfer of proteins on small reversed-phase columns. The coefficient of mass transfer was found to be a linear function of the protein translational diffusion coefficient and inversely proportional to the square of the support particle diameter, as predicted by chromatographic theory. As an example of the practical application of this method for the measurement of protein diffusion coefficients, the denaturation of bovine serum albumin with decreasing solution pH was followed by measuring the change in the coefficient of mass transfer. A major advantage of this method was that the results were not affected by the interaction of the protein with the stationary phase.  相似文献   

5.
Two-dimensional liquid chromatography (2D-LC) coupled on-line with electrospray ionization tandem mass spectrometry (2D-LC-ESI-MS/MS) is a new platform for analysis and identification of proteome. Peptides are separated by 2D-LC and then performed MS/MS analysis by tandem MS/MS. The MS/MS data are searched against database for protein identification. In one 2D-LC-ESI-MS/MS run, we obtained not only the structural information of peptides directly from MS/MS, but also the retention time of peptides eluted from LC. Information on the chromatographic behavior of peptides can assist protein identification in the new platform for proteomics. The retention time of the matching peptides of the identified protein was predicted by the hydrophobic contribute of each amino acid on reversed-phase liquid chromatography (RPLC). By using this strategy proteins were identified by four types of information: peptide mass fingerprinting (PMF), sequence query, and MS/MS ions searched and the predicted retention time. This additional information obtained from LC could assist protein identification with no extra experimental cost.  相似文献   

6.
The majority of proteome-wide studies rely on the high separation power of two-dimensional liquid chromatography-tandem mass spectrometry (2D LC-MS/MS), often combined with protein prefractionation. Alternative approaches would be advantageous in order to reduce the analysis time and the amount of sample required. On the basis of the recent advances in chromatographic and mass spectrometric instrumentation, thousands of proteins can be identified in a single-run LC-MS/MS experiment using ultralong gradients. Consequently, the analysis of simple proteomes or clinical samples in adequate depth becomes possible by performing single-run LC-MS/MS experiments. Here we present a generally applicable protocol for protein analysis from unseparated whole-cell extracts and discuss its potential and limitations. Demonstrating the practical applicability of the method, we identified 2,761 proteins from a HeLa cell lysate, requiring around 10 h of nanoLC-MS/MS measurement time.  相似文献   

7.
Selected reaction monitoring (SRM) is a highly selective and sensitive mass spectrometric methodology for precise and accurate quantification of low-abundant proteins in complex mixtures and for characterization of modified peptides, and constitutes the method of choice in targeted proteomics. Owing to its outstanding features, SRM arises as an alternative to antibody-based assays for discovery and validation of clinically relevant biomarkers, a topic that is tackled in this article. Several of the obstacles encountered in SRM experiments, mainly those derived from shared physicochemical properties of peptides (e.g., mass, charge and chromatographic retention time), can compromise selectivity and quantitation. We illustrate how to circumvent these limitations on the basis of using time-scheduled chromatographic approaches and choosing appropriate spectrometric conditions, including the careful selection of the precursor and diagnostic ions.  相似文献   

8.
Capillary liquid chromatography (cLC) coupled with matrix-assisted laser desorption/ionization (MALDI) time-of-flight mass spectrometry (TOF-MS) was used to compare small proteins and peptides extracted from Bacillus subtilis spores grown on four different media. A single, efficient protein separation, compatible with MALDI-MS analysis, was employed to reduce competitive ionization between proteins, and thus interrogate more proteins than possible using direct MALDI-MS. The MALDI-MS data files for each fraction are assembled as two-dimensional data sets of retention time and mass information. This method of visualizing small protein data required careful attention to background correction as well as mass and retention time variability. The resulting data sets were used to create comparative displays of differences in protein profiles between different spore preparations. Protein differences were found between two different solid media in both phase bright and phase dark spore phenotype. The protein differences between two different liquid media were also examined. As an extension of this method, we have demonstrated that candidate protein biomarkers can be trypsin digested to provide identifying peptide fragment information following the cLC-MALDI experiment. We have demonstrated this method on two markers and utilized acid breakdown information to identify one additional marker for this organism. The resulting method can be used to identify discriminating proteins as potential biomarkers of growth media, which might ultimately be used for source attribution.  相似文献   

9.
The complexity and diversity of biological samples in proteomics require intensive fractionation ahead of mass spectrometry identification. This work developed a chromatographic method called virtual three-dimensional chromatography to fractionate complex protein mixtures. By alternate elution with different pHs and salt concentrations, we implemented pH and salt steps by turns on a single strong cation exchange column to fully exploit its chromatographic ability. Given standard proteins that were not resolved solely by pH or salt gradient elution could be successfully separated using this combined mode. With a reversed phase column tandem connected behind, we further fractionated as well as desalted proteins as the third dimension. This present strategy could readily be adapted with respect to special complexity of biological samples. Crude plasma without depleting high abundance proteins were fractionated by this three-dimensional mode and then analyzed by reversed phase liquid chromatography coupled with LTQ mass spectrometry. In total, 1933 protein groups with wide dynamic ranges were identified from a single experiment. Some characteristics that correlated to the behavior of proteins on strong cation exchange columns are also discussed.  相似文献   

10.
The effectiveness of proteome-wide protein identification and quantitative expression profiling is dependent on the ability of the analytical methodologies employed to routinely obtain information on low-abundance proteins, as these are frequently of great biological importance. Two-dimensional gel electrophoresis, the traditional method for proteome analysis, has proven to be biased toward highly expressed proteins. Recently, two-dimensional chromatography of the complex peptide mixtures generated by the digestion of unseparated protein samples has been introduced for the identification of their components, and isotope-coded affinity tags (ICAT) have been introduced to allow for accurate quantification of the components of protein mixtures by mass spectrometry. Here, we demonstrate that the combination of isotope coded affinity protein tags and multidimensional chromatography/mass spectrometry of tryptic peptide mixtures is capable of detecting and quantifying proteins of low abundance in complex samples.  相似文献   

11.
Peptides, proteins, single-stranded oligonucleotides, and double-stranded DNA fragments were separated with high resolution in micropellicular, monolithic capillary columns prepared by in situ radical copolymerization of styrene and divinylbenzene. Miniaturized chromatography both in the reversed-phase and the ion-pair reversed-phase mode could be realized in the same capillary column because of the nonpolar character of the poly-(styrene/divinylbenzene) stationary phase. The high chromatographic performance of the monolithic stationary phase facilitated the generation of peak capacities for the biopolymers in the range of 50-140 within 10 min under gradient elution conditions. Employing volatile mobile phase components, separations in the two chromatographic separation modes were on-line hyphenated to electrospray ionization (tandem) mass spectrometry, which yielded intact accurate molecular masses as well as sequence information derived from collision-induced fragmentation. The inaccuracy of mass determination in a quadrupole ion trap mass spectrometer was in the range of 0.01-0.02% for proteins up to a molecular mass of 20000, and 0.02-0.12% for DNA fragments up to a molecular mass of 310000. High-performance liquid chromatography-electrospray ionization mass spectrometry utilizing monolithic capillary columns was applied to the identification of proteins by peptide mass fingerprinting, tandem mass spectrometric sequencing, or intact molecular mass determination, as well as to the accurate sizing of double-stranded DNA fragments ranging in size from 50 to 500 base pairs, and to the detection of sequence variations in DNA fragments amplified by the polymerase chain reaction.  相似文献   

12.
In this report, we examine the performance of a mass spectrometry (MS)-based method for quantification of protein posttranslational modifications (PTMs) using stable isotope labeled internal standards. Uniform labeling of proteins and highly similar behavior of the labeled vs nonlabeled analyte pairs during chromatographic separation and electrospray ionization (ESI) provide the means to directly quantify a wide range of PTMs. In the companion report (Jiang et al., Anal. Biochem., 421 (2012) 506-516.), we provided principles and example applications of the method. Here we show satisfactory accuracy and precision for quantifying protein modifications by using the SILIS method when the analyses were performed on different types of mass spectrometers, such as ion-trap, time-of-flight (TOF), and quadrupole instruments. Additionally, the stable isotope labeled internal standard (SILIS) method demonstrated an extended linear range of quantification expressed in accurate quantification up to at least a 4 log concentration range on three different types of mass spectrometers. We also demonstrate that lengthy chromatographic separation is no longer required to obtain quality results, offering an opportunity to significantly shorten the method run time. The results indicate the potential of this methodology for rapid and large-scale assessment of multiple quality attributes of a therapeutic protein in a single analysis.  相似文献   

13.
Recombinant monoclonal antibodies (MAbs) have become one of the most rapidly growing classes of biotherapeutics in the treatment of human disease. MAbs are highly heterogeneous proteins, thereby requiring a battery of analytical technologies for their characterization. However, incompatibility between separation and subsequent detection is often encountered. Here we demonstrate the utility of a generic on-line liquid chromatography–mass spectrometry (LC-MS) method operated in a two-dimensional format toward the rapid characterization of MAb charge and size variants. Using a single chromatographic system capable of running two independent gradients, up to six fractions of interest from an ion exchange (IEC) or size exclusion (SEC) separation can be identified by trapping and desalting the fractions onto a series of reversed phase trap cartridges with subsequent on-line analysis by mass spectrometry. Analysis of poorly resolved and low-level peaks in the IEC or SEC profile was facilitated by preconcentrating fractions on the traps using multiple injections. An on-line disulfide reduction step was successfully incorporated into the workflow, allowing more detailed characterization of modified MAbs by providing chain-specific information. The system is fully automated, thereby enabling high-throughput analysis with minimal sample handling. This technology provides rapid data turnaround time, a much needed feature during product characterization and development of multiple biotherapeutic proteins.  相似文献   

14.
MS protein identification and quantitation are key proteomic techniques in biological research. Besides identification of proteins, MS is used increasingly to characterize secondary protein modifications. This often requires trimming the analytical strategy to a specific type of modification. Direct analysis of protein modifications in proteomic samples is often hampered by the limited dynamic range of current analytical tools. Here we present a fast, sensitive, multiplexed precursor ion scanning mode--implemented on a quadrupole-TOF instrument--that allows the specific detection of any modified peptide or molecule that reveals itself by a specific fragment ion or pattern of fragment ions within a complex proteomic sample. The high mass accuracy of the TOF mass spectrometer is available for the marker ion specificity and the precursor ion mass determination. The method is compatible with chromatographic separation. Fragment ions and intact molecular ions are acquired quasi-simultaneously by continuously switching the collision energy between elevated and low levels. Using this technique many secondary modifications can be analyzed in parallel; however, the number of peptides carrying a specific modification that can be analyzed successfully is limited by the chromatographic resolution or, more generally, by the depth of the resolved time domain.  相似文献   

15.
16.
It is known that protein adsorption is the initial interaction between implanted biomaterials and biological environment. Generally, a complex protein layer will be formed on material surfaces within a few minutes and the composition of this layer at the interface determines the biological response to the implanted material, and therefore the long-term compatibility of the biomaterial. Despite different techniques exist to observe protein adsorption on biomaterials, none of them led to the identification of adsorbed proteins. In this paper, we report a chromatographic technique coupled to proteomics to analyse and identify proteins from complex biological samples adsorbed on biomaterial surfaces. This approach is based on (1) elaboration of the chromatographic support containing the biomaterial (2) a chromatography step involving adsorption of proteins on the biomaterial (3) the high-resolution separation of eluted proteins by 2-DE gel and (4) the identification of proteins by mass spectrometry. Experiments were performed with proteins from platelets rich plasma (PRP) adsorbed on a biomaterial which consist in titanium bioactivated with PolyNaSS. Our results show that chromatographic approach combined to 2-DE gels and mass spectrometry provides a powerful tool for the analysis and identification of proteins adsorbed on various surfaces.  相似文献   

17.
Zetaprep mass ion-exchange media represent a rapid and efficient chromatographic tool in the separation of proteins, in place of the conventional agarose or cellulose-based gels. We adopted this method, combined with classical steps, to purify to homogeneity human recombinant interleukin 1 beta (IL-1 beta) produced from E. coli and from S. cerevisiae. An anion exchanger QAE-ZetaPrep was used to achieve a rapid partial purification of both proteins. The IL-1 beta purification was completed by gel permeation chromatography on Sephadex G-50. When the protein was produced from yeast, an intermediate chromatographic step on a hydroxylapatite column was also necessary. The isolated proteins proved to be homogeneous by electrophoresis and amino acid analysis. The biological activity of IL-1 beta produced by E. coli is comparable to that of the natural protein, while the protein produced by yeast showed very low specific activity.  相似文献   

18.

Background

Liquid chromatography combined with tandem mass spectrometry is an important tool in proteomics for peptide identification. Liquid chromatography temporally separates the peptides in a sample. The peptides that elute one after another are analyzed via tandem mass spectrometry by measuring the mass-to-charge ratio of a peptide and its fragments. De novo peptide sequencing is the problem of reconstructing the amino acid sequences of a peptide from this measurement data. Past de novo sequencing algorithms solely consider the mass spectrum of the fragments for reconstructing a sequence.

Results

We propose to additionally exploit the information obtained from liquid chromatography. We study the problem of computing a sequence that is not only in accordance with the experimental mass spectrum, but also with the chromatographic retention time. We consider three models for predicting the retention time and develop algorithms for de novo sequencing for each model.

Conclusions

Based on an evaluation for two prediction models on experimental data from synthesized peptides we conclude that the identification rates are improved by exploiting the chromatographic information. In our evaluation, we compare our algorithms using the retention time information with algorithms using the same scoring model, but not the retention time.
  相似文献   

19.
The chromatographic separation of an unstable protein is often a challenge to the scientist working in the field of life sciences. Especially for the purification of sensitive enzymes, making use of conventional chromatographic techniques is difficult and frequently results in a complete loss of biological activity of the target protein. This report summarizes some general strategies that may help to keep unstable proteins in their native conformation during the rather harsh conditions of a purification procedure. In this context, a recently developed hollow fiber membrane module, suitable for performing on-line dialysis, is introduced and examples of its application to liquid column chromatography are given. Many innovative separation techniques, characterized by dramatic improvements in both performance and separation time, have recently been developed. Since the chromatographic separation of unstable proteins requires the use of modern state-of-the-art equipment and technology, emphasis is given to newly developed separation techniques such as expanded bed adsorption, perfusion chromatography, protein free flow electrophoresis and the use of tentacle gels. In addition, examples of recently published purifications of unstable proteins are discussed with respect to strategies ensuring the preservation of the native protein structure during chromatographic separation.  相似文献   

20.
A method for the easy isolation and direct sequencing of N-terminally blocked peptide in proteins refractory to N-terminal sequencing was developed. It is based essentially on tandem enzymatic treatments of the protein with trypsin and carboxypeptidase B, and selective isolation of the Nalpha-blocked peptide using ion-exchange chromatography. The chromatographic step was optimized for picomole amounts of sample and very short elution times by placing a thin layer of the resin over the membrane of an ultrafiltration tube. The isolated fraction can be analyzed directly using MALDI or ESI mass spectrometry. The method was applied to several recombinant and natural N-terminal acetylated proteins. A critical discussion on the intrinsic limitations of the method is also given.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号