首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
Serum paraoxonase (PON) is associated with plasma high density lipoproteins, and prevents the oxidative modification of low density lipoproteins. We have developed a sensitive sandwich enzyme-linked immunosorbent assay (ELISA), using two monoclonal antibodies against PON, to measure serum PON concentration. The concentration of PON in healthy Japanese subjects was 59.3 +/- 1.3 microgram/mL (mean +/- SEM; n = 87). Serum PON concentrations in relation to the PON 192 genetic polymorphism were: 69.5 +/- 2.9 microgram/mL in the QQ genotype; 63.0 +/- 1.9 microgram/mL in the QR genotype; and 52.8 +/- 1.7 microgram/mL in the RR genotype. Concentrations were significantly lower in the RR than in the QQ genotype (P < 0.01). Serum paraoxonase specific activity was higher in RR than in QQ subjects (18.6 +/- 0.40 vs. 2. 56 +/- 0.05 nmol/min/microgram, P < 0.01), but arylesterase specific activity was unrelated to genotype. PON concentration was positively associated (P < 0.001) with both serum arylesterase activity and, after adjusting for the effect of the position 192 polymorphism, with serum paraoxonase activity. Subjects with angiographically verified coronary heart disease had significantly lower PON concentrations than the healthy controls (52.0 +/- 2.3 microgram/mL; n = 35, P < 0.01). This association was independent of the position 192 genotype. Our new ELISA should be of value for epidemiologic and clinical studies of serum PON concentration. immunosorbent assay for human serum paraoxonase concentration.  相似文献   

2.
Apolipoprotein A-V (apoA-V) is a recently discovered apolipoprotein that appears to have a role in plasma triglyceride (TG) transport. We have developed an ELISA for apoA-V using monoclonal antibodies that has a lower limit of detection of 0.3 ng/ml and linearity up to 20 ng/ml. The ELISA was then used to quantify plasma apoA-V in 196 healthy subjects and 106 patients with insulin-resistant diabetes mellitus. In the healthy subjects, total apoA-V concentration was 179.2 +/- 74.8 ng/ml, and it was greater in females than in males (P < 0.005). It was correlated positively with the plasma HDL cholesterol (r = 0.32, P < 0.0001), apoA-I (r = 0.27, P = 0.0001), and apoE (r = 0.18, P = 0.011) concentrations and negatively with plasma TG concentration (r = -0.22, P = 0.021). In relation to single nucleotide polymorphism 3 (-1131C/T) of the apoA-V gene, apoA-V concentration was higher in the T/T type than in the C/C type (P < 0.01). Plasma TG concentration was lower in the T/T type than in the C/C or C/T type (P < 0.05). ApoA-V concentration was lower in the diabetic patients (69.4 +/- 44.3 ng/ml; P < 0.01) than in the healthy controls.  相似文献   

3.
Tissue transglutaminase (tTG) is a calcium-dependent enzyme that catalyzes crosslinking of peptidic glutamine residues with primary amines via isopeptide bonds and hydrolysis of ATP or GTP. The enzyme exerts a variety of functions at the cellular and tissue levels that may be disturbed in disease. Its role in pathoprocesses is poorly understood. For investigation of the involvement of tTG in disease, sensitive and specific assays should be available. We have developed the first sandwich enzyme-linked immunosorbent assay (ELISA) based on two monoclonal antibodies (mabs) against human tTG. tTG is captured by mab 3C10 and detected by biotinylated mab 10F3. After incubation with peroxidase-conjugated streptavidin, bound tTG is visualized by peroxidase reaction applying a luminescence substrate. The detection limit was 40 pg/ml. The assay was highly reproducible. Recovery of spiked tTG in crude samples was greater than 92%. The enzyme could be detected in cellular lysates and tissue homogenates of humans. The effect of typical effectors (retinoic acid and interferon-γ) on tTG expression could be demonstrated. A low signal was also obtained in mice samples, suggesting cross-reactivity of the mabs with murine tTG. The new sandwich ELISA may be successfully applied for investigation of physiological functions of tTG and of disorders associated with inadequate tTG expression.  相似文献   

4.
We have developed a fibrinogen-specific sandwich enzyme-linked immunosorbent assay (ELISA) microarray assay for use in qualitatively distinguishing between blood plasma and serum samples. Three capture antibodies (49D2, HPA001900, and F8512) were evaluated in conjunction with 1D6 as the detection antibody. The data show that 49D2 and (to a lesser extent) F8512 successfully identify previously unknown plasma and serum samples based on approximately a 28-fold difference in signal intensity between the sample types. This assay has utility in rapidly identifying previously archived clinical samples with incomplete annotation in a high-throughput manner prior to proteomic analyses.  相似文献   

5.
The quantitation of low-molecular-weight haptens has been difficult with conventional sandwich immunoassays due to their small size. Many researchers have attempted to develop sandwich assays for haptens due to the significant advantages of the sandwich format over competitive assays including greater dynamic range, ease of automation, and sensitivity. Here we apply the open-sandwich ELISA (OS-ELISA), an immunoassay based on antigen-dependent stabilization of antibody variable regions (V(H) and V(L) domains), to hapten quantitation. Two fusion proteins, the high-affinity mutant V(H) domain from anti-4-hydroxy-3-nitrophenacetyl (NP) antibody B1-8 tethered with Escherichia coli alkaline phosphatase (V(H)(W33L)-PhoA) and the V(L) domain from the same antibody tethered with Streptococcus sp. protein G, were made. These fusion proteins when added together achieved Fv reassociation consequent to the addition of NP. Signal was generated in a direct relationship to the NP concentration with better sensitivity compared with competitive immunoassay, demonstrating this assay to be a quick noncompetitive alternative to the conventional assays for small compounds, such as environmental pollutants, drugs of abuse, and therapeutic drugs. With our previous demonstration that the OS-ELISA works well with large proteins, the OS-ELISA becomes the first practical immunoassay approach capable of quantifying any molecule regardless of their size.  相似文献   

6.
The standard ELISA technique was improved for the detection of antigalactocerebroside antibody in biological fluid. Mouse monoclonal antigalactocerebroside antibody was used to demonstrate specificity and sensitivity of the technique. After optimization of the assay, the usefulness of this measurement for the evaluation of patients with multiple sclerosis was assessed. The presence of antigalactocerebroside antibodies in the cerebrospinal fluid of 20 patients with multiple sclerosis, 10 with other neurological diseases and 10 normal individuals was determined. All the CSF samples from normal individuals were negative. In patients with multiple sclerosis 14 of the 20 samples had elevated levels of antigalactocerebroside antibody, whereas with other neurological diseases 5 out of 10 were positive. Antigalactocerebroside levels were lower in samples from patients during an acute relapse than in those from more chronic cases. These results indicate that the presence of anti-galactocerebroside antibody in cerebrospinal fluid is not specific to MS but may reflect previous damage to myelin.Abbreviations and trivial names used ELISA Enzyme-Linked Immunosorbent Assay - CSF cerebrospinal fluid; galacto- or glucocerebroside, ceramide-1-0-beta-galactoside or-glucoside  相似文献   

7.
This work aimed to evaluate a method to detect the residual ricin in animal tissues. Immunoprecipitation and sandwich enzyme-linked immunosorbent assay (ELISA) were used to detect ricin in the tissues of intoxicated mice. The monoclonal antibodies (Mabs) 4C13 and 3D74 were used to assay the whole ricin molecules via sandwich ELISA. Mab 4C13 was conjugated with Sepharose 4B to capture ricin or ricin A chain by immunoprecipitation. Mice injected intravenously with ricin at the dosage of 5 μg/mouse were killed at different time points after intoxication. The serum, liver, kidney, lung, and intestine were harvested. High levels of ricin were found in serum and liver samples at each poisoning time point by sandwich ELISA, suggesting the possibility of determining ricin intoxication by detecting residual ricin in the serum. However, this method turned out to be ineffective for examining ricin in the kidney, lung, and intestine of poisoned mice. Although the same tissue samples of intoxicated mice were analyzed by immunoprecipitation, positive bands were found. This indicated that some components in the kidney, lung, and intestine could bind with ricin and interfere in its binding activity with the coated antibody. Immunoprecipitation could be used to measure the existence of ricin in these samples.  相似文献   

8.
With the aim of understanding virus movement and fluctuations in the virus concentration in bulb and leaves of onion (Allium cepa L.) plants after infection, Onion yellow dwarf virus (OYDV) was analysed by double-antibody sandwich enzyme-linked immunosorbent assay (DAS-ELISA). OYDV concentrations were higher in onion leaves of plants grown from tested bulbs compared with bulbs, although the virus was successfully detected in bulb of onion.  相似文献   

9.
Enzyme-linked immunosorbent assays (ELISAs) are applied for the quantification of a vast diversity of small molecules. However, ELISAs require that the antigen is present in a soluble form in the sample. Accordingly, the few ELISAs described so far targeting insoluble proteins such as integral membrane and scaffold proteins have been restricted by limited extraction efficiencies and the need to establish an individual solubilization protocol for each protein. Here we describe a sandwich ELISA that allows the quantification of a diverse array of synaptic membrane and scaffold proteins such as munc13-1, gephyrin, NMDA R1 (N-methyl-d-aspartate receptor subunit 1), synaptic vesicle membrane proteins, and SNAREs (soluble N-ethylmaleimide-sensitive factor attachment protein receptors). The assay is based on initial solubilization by the denaturing detergent sodium dodecyl sulfate (SDS), followed by partial SDS removal using the detergent Triton X-100, which restores antigenicity while keeping the proteins in solution. Using recombinant standard proteins, we determined assay sensitivities of 78 ng/ml to 77 pg/ml (or 74-0.1 fmol). Calibration of the assay using both immunoblotting and mass spectroscopy revealed that in some cases correction factors need to be included for absolute quantification. The assay is versatile, allows parallel processing and automation, and should be applicable to a wide range of hitherto inaccessible proteins.  相似文献   

10.
A sensitive and specific enzyme-liked immunosorbent assay for endoglucanase I (EG-I) has been developed. The monoclonal antibody a-EG-I 2, directed against an epitope on the core part of the enzyme, was used to capture the antigen in microtiter plate wells. A second, polyclonal antibody against the enzyme was then used to detect and quantitate the bound antigen. The test was specific for EG-I; neither endoglucanase II nor cellobiohydrolase I or II interfered. As little as 20 pg of EG-I protein could be detected. The coefficients of variation were 3.8% within plates and 6% between plates for a diluted Trichoderma reesei culture supernatant that contained 31 ng of EG-I per ml. Binding of the antigen to the monoclonal antibody was pH dependent and restricted to values between pH 6.5 and 10.5 with a maximum around pH 9. Standard solutions of EG-I were very stable at concentrations as low as 5 ng/ml when prepared in buffer that contained 1% bovine serum albumin and that was stored at -20 degrees C. After 37 weeks the antigenicity was still 97%. With this test it was possible to monitor the production of EG-I in a cellulase-producing strain of T. reesei and to demonstrate the apparent absence of the enzyme in a strain with the eglI gene deleted.  相似文献   

11.
R Bühler 《Applied microbiology》1991,57(11):3317-3321
A sensitive and specific enzyme-liked immunosorbent assay for endoglucanase I (EG-I) has been developed. The monoclonal antibody a-EG-I 2, directed against an epitope on the core part of the enzyme, was used to capture the antigen in microtiter plate wells. A second, polyclonal antibody against the enzyme was then used to detect and quantitate the bound antigen. The test was specific for EG-I; neither endoglucanase II nor cellobiohydrolase I or II interfered. As little as 20 pg of EG-I protein could be detected. The coefficients of variation were 3.8% within plates and 6% between plates for a diluted Trichoderma reesei culture supernatant that contained 31 ng of EG-I per ml. Binding of the antigen to the monoclonal antibody was pH dependent and restricted to values between pH 6.5 and 10.5 with a maximum around pH 9. Standard solutions of EG-I were very stable at concentrations as low as 5 ng/ml when prepared in buffer that contained 1% bovine serum albumin and that was stored at -20 degrees C. After 37 weeks the antigenicity was still 97%. With this test it was possible to monitor the production of EG-I in a cellulase-producing strain of T. reesei and to demonstrate the apparent absence of the enzyme in a strain with the eglI gene deleted.  相似文献   

12.
Multivalent antigens (Ags) such as membrane proteins can be quantitated by using sandwich enzyme-linked immunosorbent assays (ELISAs), which typically show sensitivity from 0.1 to 50 ng/ml. The percentage of antigen that binds in the log-log linear region reflects the affinity of the capture antibody (CAb), and the range of linearity for assays conducted with a particular CAb is proportional to the antibody (Ab) concentration. The sandwich ELISA titration plot reflects the actual amount of Ag bound when asymmetrical configurations are used; steric hindrance that occurs with certain symmetrical configurations, especially when enzyme-Ab conjugates of greater than or equal to 10(6) daltons are used, can alter this relationship. Monoclonal CAbs bind less Ag than polyclonal CAbs. Immobilization of monoclonal CAbs by using a modified avidin-biotin system can result in greater antigen capture capacity (AgCC) than when the Abs are directly adsorbed on plastic. Adsorption of proteins on polystyrene is noncovalent and proportional to the amount added for up to 150 ng/200 microliter in a microtiter well. Adsorption can result in substantial loss of antigenic or antibody activity. Desorption is continuous at a low level and can negatively influence the results of an immunoassay. Data from microtiter sandwich ELISAs can be readily acquired and analyzed by using a computer-based analysis system (ELISANALYSIS) written for the IBM PC. This analytical system considers the immunochemical principles of sandwich ELISAs predicted theoretically and demonstrated empirically.  相似文献   

13.
A rapid and sensitive screening sandwich enzyme-linked immunosorbent assay (ELISA) was developed for the detection of staphylococcal enterotoxin B (SEB) in cheese by using a highly avid anti-SEB antibody (Ab) as the capture Ab (CAb) and as the biotinylated Ab conjugate. The glutaraldehyde fixation method for the immobilization of CAb on polystyrene dipsticks was superior to the adsorption fixation and the adsorption-glutaraldehyde fixation methods. The glutaraldehyde fixation method resulted in a higher surface-saturating CAb concentration as evaluated by the peroxidase saturation technique and by the ability of the CAb-coated dipstick to discriminate between positive and negative controls (index of discrimination). Of nine blocking agents used alone or in pairs, lysine-human serum albumin, bovine serum albumin, human serum albumin, and gelatin effectively saturated available sites on the CAb-coated dipsticks without causing interference with the antigen-Ab reactions. The addition of 1% polyethylene glycol to the diluent of the biotinylated anti-SEB Ab conjugate improved the detection of SEB. A concentration of 4% polyethylene glycol allowed a 5-min reaction time for the streptavidin-biotin-horseradish peroxidase conjugate. Cheddar cheese homogenate reduced the sensitivity of the SEB assay; however, the sensitivity was restored when 1.6% (wt/vol) of either a nonionic detergent (Mega-9) or two zwitterionic detergents (Zwittergent 3-10 and 3-12 detergent) was added to the diluent. By using the rapid sandwich ELISA, a minimum of 0.5 to 1.0 ng of SEB per ml was detected within 45 min. The whole procedure for the analysis of the cheddar cheese samples was completed within 1 h.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

14.
A sensitive and specific enzyme-linked immunosorbent assay (ELISA) for nonhuman primate serum apolipoprotein A-I (apoA-I) is described. The assay is a noncompetitive, sandwich ELISA in which polystyrene microtiter plates were used with purified, monospecific goat anti-monkey apoA-I antibodies adsorbed on the wells. The serum samples were added to the coated wells, incubated, and after washing, antibodies conjugated to horseradish peroxidase were added. After further washing, the bound label was assayed. A heat treatment step, 52 degrees C for 3 hr, was used to maximize the apoA-I immunoreactive sites in diluted serum. Serum samples extracted with chloroform-methanol, delipidated with tetramethylurea, or denatured by heating gave essentially equivalent results. The working range of the apoA-I standards was 0.5 to 5 ng and parallel responses were observed for apoA-I in serum, in isolated HDL, and in buffer as a purified apoprotein. Recovery of apoA-I added to serum was quantitative (106 +/- 3%). The intra- and interassay coefficients of variation were 6.2 and 6.9%, respectively. The enzyme immunoassay yielded values that compared favorably with those obtained by radial immunodiffusion (r = 0.84). ApoA-I concentration in African green monkey serum was highly correlated with the HDL cholesterol concentration (r = 0.86). It is concluded that this ELISA is an accurate and precise method for determination of apoA-I concentrations in primate serum.  相似文献   

15.
PURPOSE: The HER-2/neu protein (p185) has become a promising target for antibody therapy in breast cancer. We tested the feasibility of a quantitative approach for HER-2/neu testing based on the analysis of tumor tissue extracts by an enzyme-linked immunosorbent assay (ELISA). EXPERIMENTAL DESIGN: Tumor tissue extracts of primary human breast cancers (n=124) were prepared using a triton-based buffer. HER-2/neu concentration was quantified by ELISA. Paraffin-embedded tissue sections of the same tumors were analyzed by immunohistochemical staining applying the monoclonal HER-2/neu antibody TAB 250 (n=124) and by chromogenic in situ hybridization (CISH) (n=73). RESULTS: Concentrations of p185 in tissue extracts determined by ELISA varied from 1 to 927 ng per mg protein with a median of 25 ng/mg protein, whereas normal breast tissue showed values from 0.4 to 5.5 ng/mg with a median of 2.2 ng/mg (p<0.0001, Mann-Whitney U test). A significant correlation between p185 concentration and immunohistochemical staining was observed (p<0.0001, Kruskal-Wallis test). In addition, p185 concentration measured by ELISA was correlated with the degree of HER-2/neu gene amplification determined by CISH. HER-2/neu-amplified tumors had significantly higher p185 concentrations (median value 181 ng/mg protein) than non-amplified tumors (median value 20 ng/mg; p<0.0001, Mann-Whitney U test). CONCLUSIONS: ELISA-based measurement of HER-2/neu protein concentration in breast cancer tissue extracts is feasible and provides quantitative results for p185 protein concentrations that correlate closely with HER-2/neu immunoscore and gene amplification.  相似文献   

16.
Adducts of benzo[a]pyrene-diolepoxide (BPDE) with blood nucleophiles have been used as biomarkers of exposure to polycyclic aromatic hydrocarbons (PAHs). The most popular such assay is a competitive enzyme-linked immunosorbent assay (ELISA) that employs monoclonal antibody 8E11 to detect benzo[a]pyrene tetrols following hydrolysis of BPDE adducts from lymphocyte DNA or human serum albumin (HSA). Here we used 8E11 as the capture antibody in a sandwich ELISA to detect BPDE-HSA adducts directly in 1-mg samples of HSA or 20 μl of serum/plasma. The assay employs an anti-HSA antibody for detection, and this is amplified by an avidin/biotinylated horseradish peroxidase complex. The sandwich ELISA has advantages of specificity and simplicity and is approximately 10 times more sensitive than the competitive ELISA. To validate the assay, HSA samples were assayed from three populations with known high PAH exposures (coke oven workers), medium PAH exposures (steel factory control workers), and low PAH exposures (volunteer subjects) (n = 30). The respective geometric mean levels of BPDE-HSA adducts—67.8, 14.7, and 1.93 ng/mg HSA (1010, 220, and 28.9 fmol BPDE equiv/mg HSA)—were significantly different (P < 0.05). The sandwich ELISA will be useful for screening PAH exposures in large epidemiologic studies and can be extended to other adducts for which capture antibodies are available.  相似文献   

17.
18.
A rapid and sensitive screening sandwich enzyme-linked immunosorbent assay (ELISA) was developed for the detection of staphylococcal enterotoxin B (SEB) in cheese by using a highly avid anti-SEB antibody (Ab) as the capture Ab (CAb) and as the biotinylated Ab conjugate. The glutaraldehyde fixation method for the immobilization of CAb on polystyrene dipsticks was superior to the adsorption fixation and the adsorption-glutaraldehyde fixation methods. The glutaraldehyde fixation method resulted in a higher surface-saturating CAb concentration as evaluated by the peroxidase saturation technique and by the ability of the CAb-coated dipstick to discriminate between positive and negative controls (index of discrimination). Of nine blocking agents used alone or in pairs, lysine-human serum albumin, bovine serum albumin, human serum albumin, and gelatin effectively saturated available sites on the CAb-coated dipsticks without causing interference with the antigen-Ab reactions. The addition of 1% polyethylene glycol to the diluent of the biotinylated anti-SEB Ab conjugate improved the detection of SEB. A concentration of 4% polyethylene glycol allowed a 5-min reaction time for the streptavidin-biotin-horseradish peroxidase conjugate. Cheddar cheese homogenate reduced the sensitivity of the SEB assay; however, the sensitivity was restored when 1.6% (wt/vol) of either a nonionic detergent (Mega-9) or two zwitterionic detergents (Zwittergent 3-10 and 3-12 detergent) was added to the diluent. By using the rapid sandwich ELISA, a minimum of 0.5 to 1.0 ng of SEB per ml was detected within 45 min. The whole procedure for the analysis of the cheddar cheese samples was completed within 1 h.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

19.
We generated two monoclonal antibodies (mAbs), 2A16 and 10G1, against pro-carboxypeptidase R (proCPR), also known as thrombin activatable fibrinolysis inhibitor (TAFI). By use of these mAbs, we developed a sandwich enzyme-linked immunosorbent assay (ELISA) system to detect proCPR. Since the amount of the antigen detectable by the ELISA was essentially the same in fresh plasma and serum incubated at 37 C for 1 hr, we concluded that the ELISA system detected not only proCPR, but also inactivated CPR generated from proCPR. However, an appreciable amount of proCPR remained unactivated in serum. For extensive activation of proCPR in plasma, thrombin and thrombomodulin complexes (TTM) can be used together with CaCl2. Following extensive conversion of proCPR to CPR by T-TM and CaCl2, converting plasma to serum (T-TM serum), antigenicity became undetectable by ELISA. Further analysis revealed that 2A16 reacts only with proCPR although 10G1 reacts with proCPR, active CPR and inactivated CPR. Therefore, we concluded that the ELISA system preferentially detects proCPR and not CPR. Our sandwich ELISA system utilizing 2A16 and 10G1 provides a suitable method for detecting proCPR and can be used to determine levels of proCPR in plasma samples from patients.  相似文献   

20.
The three murine monoclonal antibodies (MAb), D1G2, D9D10, and D13C8, are specific for human interferon-gamma (IFN-gamma), but not human IFN-alpha and IFN-beta. They react weakly with heat-treated IFN-gamma. The three antibodies recognize different epitopes of the IFN-gamma molecule, as evaluated by antibody-binding inhibition experiments. We have used these three monoclonal antibodies to construct a sandwich enzyme-linked immunosorbent assay (ELISA). The best result was obtained when we used D1G2 or D9D10 MAb as a solid-phase immunosorbent and D1G2 or D9D10 MAb as a tracer. When we measured IFN-gamma in sera by a combination of D1G2 (a solid-phase) and D1G2 (a tracer), a result similar to the one by a combination of D9D10 (a solid-phase) and D1G2 (a tracer), was obtained. This may suggest that human IFN-gamma exists in oligomeric form. Recombinant human IFN-gamma expressed in E. coli is detectable at a concentration of 1 ng/ml in this sandwich ELISA. This assay can be employed for the analysis of the structural characteristics of the human IFN-gamma molecule as well as measurement of IFN-gamma in human sera and tissue culture fluids.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号