1.
Abstract

When some antigens bind to receptors, a portion of the antigen remains exposed and can be recognized by labeled monoclonal antibodies. By measuring the amount of antibody bound to the antigen-receptor complex, one can quantify the amount of antigen that is present. Since this assay procedure depends on simultaneous receptor recognition of a biologically active site and antibody recognition of a distal epitope on the analyte, we call it a bioimmunoassay. Bioimmunoassays have many of the advantages of radioligand receptor assays (RRA) used to quantify biological activity and, depending on the choice of antibodies employed, may be more specific than RRA. In addition, since they are sandwich assays, they are usually more sensitive than RRA. Bioimmunoassays can be performed in several different modes and in the case described here we used a radiolabeled antibody to detect hormone-receptor complexes. Hence we term this example a bio-immunoradiometric assay or BIO-IRMA. We illustrate the properties of various assay procedures using a monoclonal antibody to the beta subunit of hCG which recognizes an epitope common to all other mammalian LH/hCG-like gonadotropins and which is capable of detecting 10 pg of hCG standard. In principle, this assay can be applied to any material capable of binding to a receptor, enzyme, etc. which can also be recognized by an antibody. Since it is a sandwich type of assay, it is subject to the same advantages and limitations of other sandwich assays except that it can be used to discriminate some biologically active and inactive analytes. Monoclonal antibodies which are prepared from spleen cells of animals immunized with antigen-receptor complexes and selected for their ability to bind antigen-receptor complexes should prove most useful for bioimmunoassay procedures.  相似文献   

2.
In this study we describe a novel method of sampling and quantifying wound biomarkers for clinical settings. We believe the chosen format will allow rapid assessments of wound healing and provide biomarker evidence-based decision points for treatment of the wound at the time of presentation. The wound monitoring principle uses a proprietary sample collection tool (a thermally reversible hydrogel) to sample and isolate biomarkers within a wound environment without further sample extraction/preparation steps. We show how gel samples can be analysed in a lateral flow assay format utilising fluorescent microspheres with optically discrete emission characteristics and demonstrate quantitative detection of two analytes (duplexing) achieved in a single test line. As a model assay, the chronic wound biomarkers interleukin 6 (IL6) and tumour necrosis factor alpha (TNFα) are used. Limits of detection of 48.5 pg/mL and 55.5 pg/mL respectively in hydrogel samples and 7.15 pg/mL and 10.7 pg/mL respectively in plasma are reported. We believe this is the first literature example of quantitative detection of multiple analytes within a single test line using spectral separation to distinguish the analytes.  相似文献   

3.
Homogeneous assays are attractive because they are performed in only one phase, namely, the liquid phase, and thus, they do not require separation of phases as their heterogeneous counterparts do. As opposed to heterogeneous assays, the signal generation in a homogeneous assay is a direct result of analyte binding, which allows the multiple washing and incubation steps required in an indirect heterogeneous assay format to be eliminated. Moreover, homogeneous assays are usually fast and amenable to miniaturization and automation. In this article, we describe the development of a homogeneous assay for the hormone cortisol using the bioluminescent photoprotein aequorin as a reporter molecule. A cortisol derivative was chemically conjugated to the lysine residues of a genetically modified aequorin in order to prepare an aequorin-cortisol conjugate capable of binding anticortisol antibodies. The binding of anticortisol antibodies to the aequorin-cortisol conjugate resulted in a linear response reflected in the emission of bioluminescence by aequorin. A competitive binding assay was developed by simultaneously incubating the aequorin-cortisol conjugate, the anticortisol antibodies, and the sample containing free cortisol. Dose-response curves were generated relating the intensity of the bioluminescence signal with the concentration of free cortisol in the sample. The optimized homogeneous immunoassay produced a detection limit of 1 x 10 (-10) M of free cortisol, with a linear dynamic range spanning from 1 x 10 (-5) to 1 x 10 (-9) M. Both serum and salivary levels of cortisol fall well within this assay's linear range (3.0 x 10 (-7) M to 7.5 x 10 (-7) M and 1.0 x 10 (-8) M to 2.5 x 10 (-8) M, respectively), thereby making this assay attractive for the analysis of this hormone in biological samples. To that end, it was demonstrated that the assay can be reliably used to measure the concentration of free cortisol in saliva without significant pretreatment of the sample.  相似文献   

4.
We demonstrate a functional in vitro proof-of-principle homogeneous assay capable of detecting small (<1 kDa) to large (150 kDa) analytes using TEM-1 β-lactamase protein fragment complementation. In the assays reported here, complementary components are added together in the presence of analyte and substrate resulting in colorimetric detection within 10-min. We demonstrate the use of functional mutations leading to either increased enzymatic activity, reduced fragment self-association or increased inhibitor resistance upon analyte driven fragment complementation. Kinetic characterization of the resulting reconstituted enzyme illustrates the importance of balancing increased enzyme activity with fragment self-association, producing diagnostically relevant signal-to-noise ratios. Complementation can be utilized as a homogeneous immunoassay platform for the potential detection of a range of analytes including, antibodies, antigens and biomarkers.  相似文献   

5.
The Bio-Plex(?) system utilizes xMAP technology to permit the multiplexing of up to 100 different analytes. Multiplex analysis gives researchers the ability to look at analytes simultaneously providing more information from less sample volume in less time than traditional immunoassay methods. Similar to ELISA, xMAP utilizes an antibody sandwich for detection but differs from ELISA in capture substrate and detection method. Rather than a flat surface, Bio-Plex(?) assays make use of differentially detectable bead sets as a substrate capturing analytes in solution and employs fluorescent methods for detection. These bead sets identify the analytes and detection antibodies are used to measure the quantity of analyte. The use of differentially detectable beads enables the simultaneous identification and quantification of many analytes in the same sample.  相似文献   

6.
A multianalyte immunoassay for simultaneous detection of three analytes (hTSH, hCG and beta-Gal) has been demonstrated using DNA-labeled antibodies and polymerase chain reaction (PCR) for amplification of assay response. The labeled antibodies were prepared by covalently coupling uniquely designed DNA oligonucleotides to each of the analyte-specific monoclonal antibodies. Each of the DNA oligonucleotide labels contained the same primer sequences to facilitate co-amplification by a single primer pair. Assays were performed using a two-antibody sandwich assay format and a mixture of the three DNA-labeled antibodies. Dose-response relationships for each analyte were demonstrated. Analytes were detected at sensitivities exceeding those of conventional enzyme immunoassays by approximately three orders of magnitude. Detection limits for hTSH, beta-Gal and hCG were respectively 1 x 10(-19), 1 x 10(-17) and 1 x 10(-17) mol. Given the enormous amplification afforded by PCR and the existing capability to differentiate DNA based on size or sequence differences, the use of DNA-labeled antibodies could provide the basis for the simultaneous detection of many analytes at sensitivities greater than those of existing antigen detection systems. These findings in concert with previous reports suggest this hybrid technology could provide a new generation of ultra-sensitive multianalyte immunoassays.  相似文献   

7.
We describe the use of fluorophore-doped nanoparticles as reporters in a recently developed ArcDia TPX bioaffinity assay technique. The ArcDia TPX technique is based on the use of polymer microspheres as solid-phase reaction carrier, fluorescent bioaffinity reagents, and detection of two-photon excited fluorescence. This new assay technique enables multiplexed, separation-free bioaffinity assays from microvolumes with high sensitivity. As a model analyte we chose C-reactive protein (CRP). The assay of CRP was optimized for assessment of CRP baseline levels using a nanoparticulate fluorescent reporter, 75 nm in diameter, and the assay performance was compared to that of CRP assay based on a molecular reporter of the same fluorophore core. The results show that using fluorescent nanoparticles as the reporter provides two orders of magnitude better sensitivity (87 fM) than using the molecular label, while no difference between precision profiles of the different assay types was found. The new assay method was applied for assessment of baseline levels of CRP in sera of apparently healthy individuals.  相似文献   

8.

Many environmental applications exist for biosensors capable of providing real-time analyses. One pressing current need is monitoring for agents of chemical- and bio-terrorism. These applications require systems that can rapidly detect small organics including nerve agents, toxic proteins, viruses, spores and whole microbes. A second area of application is monitoring for environmental pollutants. Processing of grab samples through chemical laboratories requires significant time delays in the analyses, preventing the rapid mapping and cleanup of chemical spills. The current state of development of miniaturized, integrated surface plasmon resonance (SPR) sensor elements has allowed for the development of inexpensive, portable biosensor systems capable of the simultaneous analysis of multiple analytes. Most of the detection protocols make use of antibodies immobilized on the sensor surface. The Spreeta 2000 SPR biosensor elements manufactured by Texas Instruments provide three channels for each sensor element in the system. A temperature-controlled two-element system that monitors for six analytes is currently in use, and development of an eight element sensor system capable of monitoring up to 24 different analytes will be completed in the near future. Protein toxins can be directly detected and quantified in the low picomolar range. Elimination of false positives and increased sensitivity is provided by secondary antibodies with specificity for different target epitopes, and by sensor element redundancy. Inclusion of more than a single amplification step can push the sensitivity of toxic protein detection to femtomolar levels. The same types of direct detection and amplification protocols are used to monitor for viruses and whole bacteria or spores. Special protocols are required for the detection of small molecules. Either a competition type assay where the presence of analyte inhibits the binding of antibodies to surface-immobilized analyte, or a displacement assay, where antibodies bound to analyte on the sensor surface are displaced by free analyte, can be used. The small molecule detection assays vary in sensitivity from the low micromolar range to the high picomolar.

  相似文献   

9.
Many environmental applications exist for biosensors capable of providing real-time analyses. One pressing current need is monitoring for agents of chemical- and bio-terrorism. These applications require systems that can rapidly detect small organics including nerve agents, toxic proteins, viruses, spores and whole microbes. A second area of application is monitoring for environmental pollutants. Processing of grab samples through chemical laboratories requires significant time delays in the analyses, preventing the rapid mapping and cleanup of chemical spills. The current state of development of miniaturized, integrated surface plasmon resonance (SPR) sensor elements has allowed for the development of inexpensive, portable biosensor systems capable of the simultaneous analysis of multiple analytes. Most of the detection protocols make use of antibodies immobilized on the sensor surface. The Spreeta 2000 SPR biosensor elements manufactured by Texas Instruments provide three channels for each sensor element in the system. A temperature-controlled two-element system that monitors for six analytes is currently in use, and development of an eight element sensor system capable of monitoring up to 24 different analytes will be completed in the near future. Protein toxins can be directly detected and quantified in the low picomolar range. Elimination of false positives and increased sensitivity is provided by secondary antibodies with specificity for different target epitopes, and by sensor element redundancy. Inclusion of more than a single amplification step can push the sensitivity of toxic protein detection to femtomolar levels. The same types of direct detection and amplification protocols are used to monitor for viruses and whole bacteria or spores. Special protocols are required for the detection of small molecules. Either a competition type assay where the presence of analyte inhibits the binding of antibodies to surface-immobilized analyte, or a displacement assay, where antibodies bound to analyte on the sensor surface are displaced by free analyte, can be used. The small molecule detection assays vary in sensitivity from the low micromolar range to the high picomolar.  相似文献   

10.
A significant challenge for all biosensor systems is to achieve high assay sensitivity and specificity while minimizing sample preparation requirements, operational complexity, and sample-to-answer time. We have achieved multiplexed, unamplified, femtomolar detection of both DNA and proteins in complex matrices (including whole blood, serum, plasma, and milk) in minutes using as few as two reagents by labeling conventional assay schemes with micrometer-scale magnetic beads, and applying fluidic force discrimination (FFD). In FFD assays, analytes captured onto a microarray surface are labeled with microbeads, and a controlled laminar flow is then used to apply microfluidic forces sufficient to preferentially remove only nonspecifically bound bead labels. The density of beads that remain bound is proportional to the analyte concentration and can be determined with either optical counting or magnetoelectronic detection of the magnetic labels. Combining FFD assays with chip-based magnetoelectronic detection enables a simple, potentially handheld, platform capable of both nucleic acid hybridization assays and immunoassays, including orthogonal detection and identification of bacterial and viral pathogens, and therefore suitable for a wide range of biosensing applications.  相似文献   

11.
A microfluidic electrochemical immunoassay system for multiplexed detection of protein cancer biomarkers was fabricated using a molded polydimethylsiloxane channel and routine machined parts interfaced with a pump and sample injector. Using off-line capture of analytes by heavily-enzyme-labeled 1 μm superparamagnetic particle (MP)-antibody bioconjugates and capture antibodies attached to an 8-electrode measuring chip, simultaneous detection of cancer biomarker proteins prostate specific antigen (PSA) and interleukin-6 (IL-6) in serum was achieved at sub-pg mL?1 levels. MPs were conjugated with ~90,000 antibodies and ~200,000 horseradish peroxidase (HRP) labels to provide efficient off-line capture and high sensitivity. Measuring electrodes feature a layer of 5 nm glutathione-decorated gold nanoparticles to attach antibodies that capture MP-analyte bioconjugates. Detection limits of 0.23 pg mL?1 for PSA and 0.30 pg mL?1 for IL-6 were obtained in diluted serum mixtures. PSA and IL-6 biomarkers were measured in serum of prostate cancer patients in total assay time 1.15 h and sensor array results gave excellent correlation with standard enzyme-linked immunosorbent assays (ELISA). These microfluidic immunosensors employing nanostructured surfaces and off-line analyte capture with heavily labeled paramagnetic particles hold great promise for accurate, sensitive multiplexed detection of diagnostic cancer biomarkers.  相似文献   

12.
A system for isolating and measuring up to 30 analytes in a single biological sample is described. The system is based on recycling a pre-labeled sample through an array of capillary immunoaffinity columns, each packed with glass beads, coated with a different antibody, thus enabling each column to isolate and extract a single analyte. Detection of the bound analytes is achieved by laser-induced fluorescence (LIF), using a laboratory-built scanning detector coupled to a fiber-optic spectrometer. The array can be regenerated up to 200 times, provided a suitable temperature is maintained. The individual immunoaffinity columns are able to bind between 2.9 and 3.6 ng of analyte, depending upon the individual column, with lower limits of detection (LOD) in the order of 1.6-2.8 pg/ml. The inter- and intra-assay coefficients of variation (CV) for all 30 columns in the array were less than 6.03+/-0.33 at analyte concentrations of 100 pg/ml. Comparison to standard enzyme-immunoassays demonstrated r(2) values in the range of 0.9151-0.9855 when analyzed by least-squares linear regression.  相似文献   

13.
上转磷光技术在快速生物分析中的应用   总被引:10,自引:0,他引:10  
上转磷光技术 (UPT)是基于上转磷光材料 (UCP)而发展起来的一种新型标记技术。UCP是由几种稀土金属元素掺杂于某些晶体的晶格中构成的纳米级颗粒。由于独特的结构 ,UCP可由红外光激发而发射可见光———上转磷光。这种特殊性质使UCP作为标记物在生物分析中 ,以无本底干扰、无淬灭、适于多重分析和定量分析等显著优势 ,从本质上有别于传统标记物。UCP将在快速免疫分析、微点阵、高通量药物筛选、基因组学研究、外科手术组织成像、食品环境检测以及生化战防御等多方面得到广泛地应用。  相似文献   

14.
The sensitivities of immunoassays relying on conventional radioisotopic labels (i.e. radioimmunoassay (RIA) and immunoradiometric assay (IRMA)) permit the measurement of analyte concentrations above ca 107 molecules/ml. This limitation primarily derives, in the case of ‘competitive’ or ‘limited reagent’ assays, from the manipulation errors arising in the system combined with the physicochemical characteristics of the particular antibody used; however, in the case of ‘non-competitive’ systems, the specific activity of the label may play a more important constraining role. It is theoretically demonstrable that the development of assay techniques yielding detection limits significantly lower than 107 molecules/ml depends on:
  • 1 the adoption of ‘non-competitive’ assays designs;
  • 2 the use of labels of higher specific activity than radioisotopes;
  • 3 highly efficient discrimination between the products of the immunological reactions involved.
Chemiluminescent and fluorescent substances are capable of yielding higher specific activities than commonly used radioisotopes when used as direct reagent labels in this context, and both thus provide a basis for the development of ‘ultra-sensitive’, non-competitive, immunoassay methodologies. Enzymes catalysing chemiluminescent reactions or yielding fluorescent reaction products can likewise be used as labels yielding high effective specific activities and hence enhanced assay sensitivities. A particular advantage of fluorescent labels (albeit one not necessarily confined to them) lies in the possibility they offer of revealing immunological reactions localized in ‘microspots’ distributed on an inert solid support. This opens the way to the development of an entirely new generatio of ‘ambient analyte’ microspot immunoassays perrnitting the simultaneous measurement of tens or even hundreds of different analytes in the same small sample, using (for example) laser scanning techniques. Early experience suggests that microspot assays with sensitivities surpassing that of isotopically based methodologies can readily be developed.  相似文献   

15.
Immunoassays based on electrochemical detection using microelectrode arrays   总被引:6,自引:0,他引:6  
We show that CombiMatrix's VLSI arrays of individually addressable electrodes, using conventional CMOS integrated circuitry, can be used in detecting various analytes via immunoassay protocols. These microarrays provide over 1000 electrodes per square centimeter. The chips are coated with a porous material on which specific affinity tags are synthesized proximate to selected electrode sites. CombiMatrix microarrays are used to develop spatially multiplexed assay formats for biological entities over a wide range of sizes, from small molecules to cells. Antibodies are tagged with coded affinity labels and then allowed to self-assemble on the appropriate electrode assay sites. Each analyte-specific antibody is chaperoned to individual, predetermined locations by the self-assembly process. The resulting chip can perform numerous different analyte-specific immunoassays, simultaneously. We present new detection technologies based upon the use of the active individually addressable microelectrodes on the chip: redox enzyme amplified electrochemical detection. The results for human alpha1 acid glycoprotein, ricin, M13 phage, Bacillus globigii spores, and fluorescein indicate that this method is one of the most sensitive available, with limits of detection in the attomole range. The detection range is 4-5 logs of analyte concentration, with an assay volume of 50 microl or less. The system provides for a host of multiplexed immunoassays because of the large number of electrodes available. We show how the assays can be optimized for maximum performance on the CombiMatrix microarray platform.  相似文献   

16.
Analysis of lateral flow biodetectors: competitive format   总被引:1,自引:0,他引:1  
Lateral flow (LF) biodetectors facilitate low-cost, rapid identification of various analytes. The LF cell consists of a porous membrane containing immobilized ligands at various locations. Through the action of capillary forces, a mixture of sample and reporter particles is transported to the ligand sites, where the target analytes and the reporters bind to the immobilized ligand. The concentration of the reporters is measured with a scanner. A mathematical model for two different competitive assays is constructed and used to study the performance of LF devices under various operating conditions. The model predicts the signal magnitude as a function of target analyte, reporter, and ligand concentrations, reaction rate constants, and flow rate. The predictions are compared and qualitatively agree with experimental data. The model provides insights into various experimental observations. Furthermore, the model can be used to optimize the performance of LF devices and to inexpensively and rapidly test the system under various operating conditions.  相似文献   

17.
Sensitive and specific electrochemiluminescence (ECL) assays were used to detect Clostridium botulinum neurotoxins serotypes A, B, E, and F in undiluted human serum, undiluted human urine, assay buffer, and selected food matrices (whole milk, apple juice, ground beef, pastry, and raw eggs). These novel assays used paramagnetic bead-based electrochemiluminescent technology in which biotinylated serotype-specific antibodies were bound to streptavidin-coated paramagnetic beads. The beads acted as the solid support and captured analyte from solution. Electrochemiluminescent detection relied on the use of ruthenium chelate-labeled anti-serotype antibodies and analysis with a BioVeris M-Series M1R analyzer. The sensitivities of the assays in clinically relevant matrices were 50 pg/ml for serotypes A and E, 100 pg/ml for serotype B, and 400 pg/ml for serotype F. The detection limits in selected food matrices ranged from 50 pg/ml for serotype A to 50 to 100 pg/ml for serotypes B, E, and F. The antibodies used for capture and detection exhibited no cross-reactivity when tested with the other serotypes. When purified native toxin was compared with toxins complexed to neurotoxin-associated proteins, no significant differences in assay response were noted for serotypes A, B, and F. Interestingly, the native form of serotype E exhibited reduced signal and limit of detection compared with the complexed form of the protein. We suspect that this difference may be due to trypsin activation of this particular serotype. The assays described in this article demonstrate limits of detection similar in range to the gold standard mouse bioassay, but with greatly reduced time to data. These rapid sensitive assays may have potential use in clinical settings, research studies, and screening of food products for botulinum toxins.  相似文献   

18.
Substances that alter the measurable concentration of the analyte or alter antibody binding can potentially result in immunoassay interference. Interfering, endogenous substances that are natural, polyreactive antibodies or autoantibodies (heterophiles), or human anti-animal antibodies together with other unsuspected binding proteins that are unique to the individual, can interfere with the reaction between analyte and reagent antibodies in immunoassay. Lipaemia, cross-reactivity, and exogenous interferences due to pre-analytical variation, matrix and equipment reaction also affect immunoassay. Interfering substances may lead to falsely elevated or falsely low analyte concentration in one or more assay systems depending on the site of the interference in the reaction and possibly result in discordant results for other analytes. The prevalence of interference is generally low in assays containing blocking agents that neutralise or inhibit the interference but is often higher in new, untested immunoassays. A wide range of analytes measured by immunoassay including hormones, tumour markers, drugs, cardiac troponin and microbial serology may be affected.Interference in immunoassay may lead to the misinterpretation of a patient's results by the laboratory and the wrong course of treatment being given by the physician. Laboratories should put processes in place to detect, test and report suspected interferences. It is equally important that physicians communicate any clinical suspicion of discordance between the clinical and the laboratory data to the laboratory. The detection of interference may require the use of an alternate assay or additional measurements, before and after treatment with additional blocking reagent, or following dilution of the sample in non-immune serum. It is imperative that laboratories inform physicians of the follow-up procedure and report on the presence of any interference. The establishment of on-going laboratory-physician contact is essential to the continuing awareness of wrong patient results due to interference.  相似文献   

19.
The residues of pyrethroids in foods of animal origin are dangerous to the consumers, so this study presented a chemiluminescence sensor for determination of pyrethroids in chicken samples. A dual‐dummy‐template molecularly imprinted polymer capable of recognizing 10 pyrethroids was synthesized. The results of computation simulation showed that the specific 3D conformations of the templates had important influences on the polymer' recognition ability. The polymer was used to prepare a sensor on conventional 96‐well microplates, and the sample solution was added into the wells for direct absorption. The absorbed analytes were initiated with the bis(2,4,6‐trichlorophenyl)oxalate–H2O2–imidazole system, and the chemiluminescence intensity was used for analyte quantification. Results showed that one assay was finished within 12 min, and this sensor could be reused four times. The limits of detection for the 10 analytes were in the range o0.3–6.0 pg/ml, and the recoveries from the standards of fortified blank chicken samples were in the range 70.5–99.7%.  相似文献   

20.
A heterogeneous, dual analyte-binding assay which makes use of the flash luminescence from both aequorin and an acridinium-9-carboxamide label is presented. The signal generating species were triggered both differentially and sequentially using Ca(2+) followed by basic peroxide. Both signals were resolved readily using a single photomultiplier tube without the need for multiwavelength detection. To demonstrate the tandem luminescence concept in a model assay system, dose-response curves for two analytes, biotinylated BSA and myoglobin, were generated using a competitive binding format. Because of the relatively short assay time and the well-resolved signals, this format will be useful in the development of dual analyte high-throughput assays.  相似文献   