首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.

Background

Image registration is to produce an entire scene by aligning all the acquired image sequences. A registration algorithm is necessary to tolerance as much as possible for intensity and geometric variation among images. However, captured image views of real scene usually produce unexpected distortions. They are generally derived from the optic characteristics of image sensors or caused by the specific scenes and objects.

Methods and Findings

An analytic registration algorithm considering the deformation is proposed for scenic image applications in this study. After extracting important features by the wavelet-based edge correlation method, an analytic registration approach is then proposed to achieve deformable and accurate matching of point sets. Finally, the registration accuracy is further refined to obtain subpixel precision by a feature-based Levenberg-Marquardt (FLM) method. It converges evidently faster than most other methods because of its feature-based characteristic.

Conclusions

We validate the performance of proposed method by testing with synthetic and real image sequences acquired by a hand-held digital still camera (DSC) and in comparison with an optical flow-based motion technique in terms of the squared sum of intensity differences (SSD) and correlation coefficient (CC). The results indicate that the proposed method is satisfactory in the registration accuracy and quality of DSC images.  相似文献   

2.

Background

Bladder cancer is the fourth most common malignancy in men, with a recurrence rate of 33–64%. Tumor documentation during cystoscopy of the bladder is suboptimal and might play a role in these high recurrence rates.

Objective

In this project, a bladder registration and navigation system was developed to improve bladder tumor documentation and consequently increase reproducibility of the cystoscopy.

Materials/Methods

The bladder registration and navigation system consists of a stereo-tracker that tracks the location of a newly developed target, which is attached to the endoscope during cystoscopy. With this information the urology registration and navigation software is able to register the 3D position of a lesion of interest. Simultaneously, the endoscopic image is captured in order to combine it with this 3D position. To enable navigation, navigational cues are displayed on the monitor, which subsequently direct the cystoscopist to the previously registered lesion. To test the system, a rigid and a flexible bladder phantom was developed. The system''s robustness was tested by measuring the accuracy of registering and navigating the lesions. Different calibration procedures were compared. It was also tested whether system accuracy is limited by using a previously saved calibration, to avoid surgical delay due to calibration. Urological application was tested by comparing a rotational camera (fixed to the rotating endoscope) to a non-rotational camera (dangling by gravity) used in standard urologic practice. Finally, the influence of volume differences on registering and navigating was tested.

Results/Conclusion

The bladder registration and navigation system has an acceptable accuracy for bladder lesion registration and navigation. Limitations for patient determinants included changes in bladder volume and bladder deformation. In vivo studies are required to measure the effect of these limitations and functionality in urological practice as a tool to increase reproducibility of the cystoscopy.  相似文献   

3.
WY Hsu 《PloS one》2012,7(7):e40558

Background

A common registration problem for the application of consumer device is to align all the acquired image sequences into a complete scene. Image alignment requires a registration algorithm that will compensate as much as possible for geometric variability among images. However, images captured views from a real scene usually produce different distortions. Some are derived from the optic characteristics of image sensors, and others are caused by the specific scenes and objects.

Methodology/Principal Findings

An image registration algorithm considering the perspective projection is proposed for the application of consumer devices in this study. It exploits a multiresolution wavelet-based method to extract significant features. An analytic differential approach is then proposed to achieve fast convergence of point matching. Finally, the registration accuracy is further refined to obtain subpixel precision by a feature-based modified Levenberg-Marquardt method. Due to its feature-based and nonlinear characteristic, it converges considerably faster than most other methods. In addition, vignette compensation and color difference adjustment are also performed to further improve the quality of registration results.

Conclusions/Significance

The performance of the proposed method is evaluated by testing the synthetic and real images acquired by a hand-held digital still camera and in comparison with two registration techniques in terms of the squared sum of intensity differences (SSD) and correlation coefficient (CC). The results indicate that the proposed method is promising in registration accuracy and quality, which are statistically significantly better than other two approaches.  相似文献   

4.

Context

Since September 2005, the International Committee of Medical Journal Editors (ICMJE) has required that randomised controlled trials (RCTs) are prospectively registered in a publicly accessible database. After registration, a trial registration number (TRN) is assigned to each RCT, which should make it easier to identify future publications and cross-check published results with associated registry entries, as long as the unique identification number is reported in the article.

Objective

Our primary objective was to evaluate the reporting of trial registration numbers in biomedical publications. Secondary objectives were to evaluate how many published RCTs had been registered and how many registered RCTs had resulted in a publication, using a sample of trials from the Netherlands Trials Register (NTR).

Design, Setting

Two different samples of RCTs were examined: 1) RCTs published in November 2010 in core clinical journals identified in MEDLINE; 2) RCTs registered in the NTR with a latest expected end date of 31 August 2008.

Results

Fifty-five percent (166/302) of the reports of RCTs found in MEDLINE and 60% (186/312) of the published reports of RCTs from the NTR cohort contained a TRN. In both samples, reporting of a TRN was more likely in RCTs published in ICMJE member journals as compared to non-ICMJE member journals (MEDLINE 58% vs. 45%; NTR: 70% vs. 49%). Thirty-nine percent of published RCTs in the MEDLINE sample appear not to have been registered, and 48% of RCTs registered in the NTR seemed not to have been published at least two years after the expected date for study completion.

Conclusion

Our results show that further promotion and implementation of trial registration and accurate reporting of TRN is still needed. This might be helped by inclusion of the TRN as an item on the CONSORT checklist.  相似文献   

5.

Background

Registration can help with transparency of acupuncture clinical trials (ACTs) by making protocol information and results available to the public. Recently, the number of registered ACTs has increased greatly, but only a few researchers have focused on the quality of ACTs registration. This review provides the first assessment of the registration quality of ACTs and the baseline information for future development.

Methods

All records of ACTs registered in the World Health Organization (WHO) International Clinical Trials Registry Platform (ICTRP) were collected. Data was extracted and input to Excel spreadsheets. The current 20 items of the WHO Trial Registration Data Set (TRDS) and the special prepared items for acupuncture intervention details were used to assess the registration quality of ACTs.

Results

A total of 740 records, found in 11 registries, were examined. The number of registered ACTs increased rapidly and involved a number of different diseases. The completeness of 20 items was not too poor due to 16 of them had a higher reported percentage (>85%). The completeness of the 20 items was different among registries. For example, the average registration percentage of 20 items in Clinicaltrials.gov, ChiCTR, ISRCTN and ANZCTR were 89.6%, 92.2%, 82.4% and 91.6% respectively. Detailed information regarding acupuncture intervention was seriously insufficient. Among the 740 registration records, 89.2% lacked information on the style of acupuncture, 80.8% did not contain details regarding the needles used, 53.5% lacked information on the treatment regimen and 76.2% did not give details of other interventions administered with acupuncture.

Conclusions

The overall registration quality of ACTs is not high enough due to the serious lack of information on the specifics of acupuncture intervention. It is vital that a number of special items be set regarding acupuncture in order to develop a suitable system for the registration of ACTs.  相似文献   

6.

Background

Current guidelines for evaluating cleft palate treatments are mostly based on two-dimensional (2D) evaluation, but three-dimensional (3D) imaging methods to assess treatment outcome are steadily rising.

Objective

To identify 3D imaging methods for quantitative assessment of soft tissue and skeletal morphology in patients with cleft lip and palate.

Data sources

Literature was searched using PubMed (1948–2012), EMBASE (1980–2012), Scopus (2004–2012), Web of Science (1945–2012), and the Cochrane Library. The last search was performed September 30, 2012. Reference lists were hand searched for potentially eligible studies. There was no language restriction.

Study selection

We included publications using 3D imaging techniques to assess facial soft tissue or skeletal morphology in patients older than 5 years with a cleft lip with/or without cleft palate. We reviewed studies involving the facial region when at least 10 subjects in the sample size had at least one cleft type. Only primary publications were included.

Data extraction

Independent extraction of data and quality assessments were performed by two observers.

Results

Five hundred full text publications were retrieved, 144 met the inclusion criteria, with 63 high quality studies. There were differences in study designs, topics studied, patient characteristics, and success measurements; therefore, only a systematic review could be conducted. Main 3D-techniques that are used in cleft lip and palate patients are CT, CBCT, MRI, stereophotogrammetry, and laser surface scanning. These techniques are mainly used for soft tissue analysis, evaluation of bone grafting, and changes in the craniofacial skeleton. Digital dental casts are used to evaluate treatment and changes over time.

Conclusion

Available evidence implies that 3D imaging methods can be used for documentation of CLP patients. No data are available yet showing that 3D methods are more informative than conventional 2D methods. Further research is warranted to elucidate it.

Systematic review registration

International Prospective Register of Systematic Reviews, PROSPERO CRD42012002041  相似文献   

7.
Superimposition of serial Cone Beam Computed Tomography (CBCT) scans has become a valuable tool for three dimensional (3D) assessment of treatment effects and stability. Voxel based image registration is a newly developed semi-automated technique for superimposition and comparison of two CBCT scans. The accuracy and reproducibility of CBCT superimposition on the anterior cranial base or the zygomatic arches using voxel based image registration was tested in this study. 16 pairs of 3D CBCT models were constructed from pre and post treatment CBCT scans of 16 adult dysgnathic patients. Each pair was registered on the anterior cranial base three times and on the left zygomatic arch twice. Following each superimposition, the mean absolute distances between the 2 models were calculated at 4 regions: anterior cranial base, forehead, left and right zygomatic arches. The mean distances between the models ranged from 0.2 to 0.37 mm (SD 0.08-0.16) for the anterior cranial base registration and from 0.2 to 0.45 mm (SD 0.09-0.27) for the zygomatic arch registration. The mean differences between the two registration zones ranged between 0.12 to 0.19 mm at the 4 regions. Voxel based image registration on both zones could be considered as an accurate and a reproducible method for CBCT superimposition. The left zygomatic arch could be used as a stable structure for the superimposition of smaller field of view CBCT scans where the anterior cranial base is not visible.  相似文献   

8.
Song S  Zhan Z  Long Z  Zhang J  Yao L 《PloS one》2011,6(2):e17191

Background

Support vector machine (SVM) has been widely used as accurate and reliable method to decipher brain patterns from functional MRI (fMRI) data. Previous studies have not found a clear benefit for non-linear (polynomial kernel) SVM versus linear one. Here, a more effective non-linear SVM using radial basis function (RBF) kernel is compared with linear SVM. Different from traditional studies which focused either merely on the evaluation of different types of SVM or the voxel selection methods, we aimed to investigate the overall performance of linear and RBF SVM for fMRI classification together with voxel selection schemes on classification accuracy and time-consuming.

Methodology/Principal Findings

Six different voxel selection methods were employed to decide which voxels of fMRI data would be included in SVM classifiers with linear and RBF kernels in classifying 4-category objects. Then the overall performances of voxel selection and classification methods were compared. Results showed that: (1) Voxel selection had an important impact on the classification accuracy of the classifiers: in a relative low dimensional feature space, RBF SVM outperformed linear SVM significantly; in a relative high dimensional space, linear SVM performed better than its counterpart; (2) Considering the classification accuracy and time-consuming holistically, linear SVM with relative more voxels as features and RBF SVM with small set of voxels (after PCA) could achieve the better accuracy and cost shorter time.

Conclusions/Significance

The present work provides the first empirical result of linear and RBF SVM in classification of fMRI data, combined with voxel selection methods. Based on the findings, if only classification accuracy was concerned, RBF SVM with appropriate small voxels and linear SVM with relative more voxels were two suggested solutions; if users concerned more about the computational time, RBF SVM with relative small set of voxels when part of the principal components were kept as features was a better choice.  相似文献   

9.

Introduction

The benefits of clinical trials registration include improved transparency on clinical trials for healthcare workers and patients, increased accountability of trialists, the potential to address publication bias and selective reporting, and possibilities for research collaboration and prioritization. However, poor quality of information in registered records of trials has been found to undermine these benefits in the past. Trialists'' increasing experience with trial registration and recent developments in registration systems may have positively affected data quality. This study was conducted to investigate whether the quality of registration has improved.

Methods

We repeated a study from 2009, using the same methods and the same research team. A random sample of 400 records of clinical trials that were registered between 01/01/2012 and 01/01/2013 was taken from the International Clinical Trials Registry Platform (ICTRP) and assessed for the quality of information on 1) contact details, 2) interventions and 3) primary outcomes. Results were compared to the equivalent assessments from our previous study.

Results

There was a small and not statistically significant increase from 81.0% to 85.5% in the percentage of records that provided a name of a contact person. There was a significant increase from 68.7% to 74.9% in the number of records that provided either an email address or a telephone number. There was a significant increase from 44.2% to 51.9% in the number of intervention arms that were complete in registering intervention specifics. There was a significant increase from 38.2% to 57.6% in the number of primary outcomes that were specific measures with a meaningful timeframe. Approximately half of all trials continued to be retrospectively registered.

Discussion

There have been small but significant improvements in the quality of registration since 2009. Important problems with quality remain and continue to constitute an impediment to the meaningful utilization of registered trial information.  相似文献   

10.

Background

Cone-beam Computed Tomography (CBCT) and stereophotography are two of the latest imaging modalities available for three-dimensional (3-D) visualization of craniofacial structures. However, CBCT provides only limited information on surface texture. This can be overcome by combining the bone images derived from CBCT with 3-D photographs. The objectives of this study were 1) to evaluate the feasibility of integrating 3-D Photos and CBCT images 2) to assess degree of error that may occur during the above processes and 3) to identify facial regions that would be most appropriate for 3-D image registration.

Methodology

CBCT scans and stereophotographic images from 29 patients were used for this study. Two 3-D images corresponding to the skin and bone were extracted from the CBCT data. The 3-D photo was superimposed on the CBCT skin image using relatively immobile areas of the face as a reference. 3-D colour maps were used to assess the accuracy of superimposition were distance differences between the CBCT and 3-D photo were recorded as the signed average and the Root Mean Square (RMS) error.

Principal Findings:

The signed average and RMS of the distance differences between the registered surfaces were −0.018 (±0.129) mm and 0.739 (±0.239) mm respectively. The most errors were found in areas surrounding the lips and the eyes, while minimal errors were noted in the forehead, root of the nose and zygoma.

Conclusions

CBCT and 3-D photographic data can be successfully fused with minimal errors. When compared to RMS, the signed average was found to under-represent the registration error. The virtual 3-D composite craniofacial models permit concurrent assessment of bone and soft tissues during diagnosis and treatment planning.  相似文献   

11.

Purpose

Using three-dimensional (3D) stereophotogrammetry precise images and reconstructions of the human body can be produced. Over the last few years, this technique is mainly being developed in the field of maxillofacial reconstructive surgery, creating fusion images with computed tomography (CT) data for precise planning and prediction of treatment outcome. Though, in hand surgery 3D stereophotogrammetry is not yet being used in clinical settings.

Methods

A total of 34 three-dimensional hand photographs were analyzed to investigate the reproducibility. For every individual, 3D photographs were captured at two different time points (baseline T0 and one week later T1). Using two different registration methods, the reproducibility of the methods was analyzed. Furthermore, the differences between 3D photos of men and women were compared in a distance map as a first clinical pilot testing our registration method.

Results

The absolute mean registration error for the complete hand was 1.46 mm. This reduced to an error of 0.56 mm isolating the region to the palm of the hand. When comparing hands of both sexes, it was seen that the male hand was larger (broader base and longer fingers) than the female hand.

Conclusions

This study shows that 3D stereophotogrammetry can produce reproducible images of the hand without harmful side effects for the patient, so proving to be a reliable method for soft tissue analysis. Its potential use in everyday practice of hand surgery needs to be further explored.  相似文献   

12.

Aim

The aim of this study is to assess the effect of the compositions of various soft tissues and tissue-equivalent materials on dose distribution in neutron brachytherapy/neutron capture therapy.

Background

Neutron brachytherapy and neutron capture therapy are two common radiotherapy modalities.

Materials and methods

Dose distributions were calculated around a low dose rate 252Cf source located in a spherical phantom with radius of 20.0 cm using the MCNPX code for seven soft tissues and three tissue-equivalent materials. Relative total dose rate, relative neutron dose rate, total dose rate, and neutron dose rate were calculated for each material. These values were determined at various radial distances ranging from 0.3 to 15.0 cm from the source.

Results

Among the soft tissues and tissue-equivalent materials studied, adipose tissue and plexiglass demonstrated the greatest differences for total dose rate compared to 9-component soft tissue. The difference in dose rate with respect to 9-component soft tissue varied with compositions of the materials and the radial distance from the source. Furthermore, the total dose rate in water was different from that in 9-component soft tissue.

Conclusion

Taking the same composition for various soft tissues and tissue-equivalent media can lead to error in treatment planning in neutron brachytherapy/neutron capture therapy. Since the International Commission on Radiation Units and Measurements (ICRU) recommends that the total dosimetric uncertainty in dose delivery in radiotherapy should be within ±5%, the compositions of various soft tissues and tissue-equivalent materials should be considered in dose calculation and treatment planning in neutron brachytherapy/neutron capture therapy.  相似文献   

13.

Background

The use of HDR in the treatment of soft tissue sarcoma had been on the rise. However, there was limited study to evaluate the effect of different fractionation schemes on soft tissue and the optimal HDR scheme.

Aims

We aimed to assess the histopathologic changes on soft tissue after different HDR brachytherapy doses.

Methods

The subjects were divided into three groups. Each group included 10 limbs. Group A had only an applicator without radiation, group B received a total of 24 Gy at 6 Gy per fraction, twice a day, and group C received a total of 13.5 Gy in a single fraction. The histopathologic findings were grouped into soft tissue pathology-1 (edema, inflammation, endothelial proliferation, necrosis) and soft tissue pathology-2 (atrophy, calcification, vascular hyalinization, fibrosis) (STP-1–2).

Results

The highest mean grade values of STP-1 and STP-2 were observed in group C (0.95 and 1.45) in comparison to group A (0.45 and 0.85) and group B (0.65 and 0.9). The difference in STP-1 was found significant only between groups A and C and the difference in STP-2 was found both between groups A and C and groups B and C.

Conclusion

In our experimental study it was shown that the fractionated interstitial HDR had both lower rate and severity of toxicity in comparison to a single high dose fraction. Before using a single fractionated regimen in the clinic, the increased morbidity related to the irreversible early toxicities or progressive late toxicities should be kept in mind.  相似文献   

14.

Objectives

Reusing baseline volumes of interest (VOI) by applying non-rigid and to some extent (local) rigid image registration showed good test-retest variability similar to delineating VOI on both scans individually. The aim of the present study was to compare response assessments and classifications based on various types of image registration with those based on (semi)-automatic tumour delineation.

Methods

Baseline (n = 13), early (n = 12) and late (n = 9) response (after one and three cycles of treatment, respectively) whole body [18F]fluoro-2-deoxy-D-glucose positron emission tomography/computed tomography (PET/CT) scans were acquired in subjects with advanced gastrointestinal malignancies. Lesions were identified for early and late response scans. VOI were drawn independently on all scans using an adaptive 50% threshold method (A50). In addition, various types of (non-)rigid image registration were applied to PET and/or CT images, after which baseline VOI were projected onto response scans. Response was classified using PET Response Criteria in Solid Tumors for maximum standardized uptake value (SUVmax), average SUV (SUVmean), peak SUV (SUVpeak), metabolically active tumour volume (MATV), total lesion glycolysis (TLG) and the area under a cumulative SUV-volume histogram curve (AUC).

Results

Non-rigid PET-based registration and non-rigid CT-based registration followed by non-rigid PET-based registration (CTPET) did not show differences in response classifications compared to A50 for SUVmax and SUVpeak,, however, differences were observed for MATV, SUVmean, TLG and AUC. For the latter, these registrations demonstrated a poorer performance for small lung lesions (<2.8 ml), whereas A50 showed a poorer performance when another area with high uptake was close to the target lesion. All methods were affected by lesions with very heterogeneous tracer uptake.

Conclusions

Non-rigid PET- and CTPET-based image registrations may be used to classify response based on SUVmax and SUVpeak. For other quantitative measures future studies should assess which method is valid for response evaluations by correlating with survival data.  相似文献   

15.

Aim

The purpose of this study was to present and validate an innovative semi-automatic approach to quantify the accuracy of the surgical outcome in relation to 3D virtual orthognathic planning among patients who underwent bimaxillary surgery.

Material and Method

For the validation of this new semi-automatic approach, CBCT scans of ten patients who underwent bimaxillary surgery were acquired pre-operatively. Individualized 3D virtual operation plans were made for all patients prior to surgery. During surgery, the maxillary and mandibular segments were positioned as planned by using 3D milled interocclusal wafers. Consequently, post-operative CBCT scan were acquired. The 3D rendered pre- and postoperative virtual head models were aligned by voxel-based registration upon the anterior cranial base. To calculate the discrepancies between the 3D planning and the actual surgical outcome, the 3D planned maxillary and mandibular segments were segmented and superimposed upon the postoperative maxillary and mandibular segments. The translation matrices obtained from this registration process were translated into translational and rotational discrepancies between the 3D planning and the surgical outcome, by using the newly developed tool, the OrthoGnathicAnalyser. To evaluate the reproducibility of this method, the process was performed by two independent observers multiple times.

Results

Low intra-observer and inter-observer variations in measurement error (mean error < 0.25 mm) and high intraclass correlation coefficients (> 0.97) were found, supportive of the observer independent character of the OrthoGnathicAnalyser. The pitch of the maxilla and mandible showed the highest discrepancy between the 3D planning and the postoperative results, 2.72° and 2.75° respectively.

Conclusion

This novel method provides a reproducible tool for the evaluation of bimaxillary surgery, making it possible to compare larger patient groups in an objective and time-efficient manner in order to optimize the current workflow in orthognathic surgery.  相似文献   

16.
X.-B. Lin  X.-X. Li  D.-M. Guo 《IRBM》2019,40(2):78-85

Background

Label fusion is a core step of Multi-Atlas Segmentation (MAS), which has a decisive effect on segmentation results. Although existed strategies using image intensity or image shape to fuse labels have got acceptable results, there is still necessity for further performance improvement. Here, we propose a new label fusion strategy, which considers the joint information of intensity and registration quality.

Methods

The correlation between any two atlases is taken into account and the probability that two atlases both give wrong label is used to compute the fusion weights. The probability is jointly determined by the registration error and intensity similarity of the two corresponding atlas-target image pairs. The proposed label fusion algorithm is named Registration Error and Intensity Similarity based Label Fusion (REIS-LF).

Results

Using 3D Magnetic Resonance (MR) images, the proposed REIS-LF algorithm is validated in brain structure segmentation including the hippocampus, the thalamus and the nuclei of the basal ganglia. The REIS-LF algorithm has higher segmentation accuracy and robustness than the baseline AQUIRC-W algorithm.

Conclusions

Taking the registration quality, the inter-atlas correlations and intensity differences into account in label fusion benefits to improve the object segmentation accuracy and robustness.  相似文献   

17.

Objectives

Invasive therapy of proximal caries lesions initiates a cascade of re-treatment cycles with increasing loss of dental hard tissue. Non- and micro-invasive treatment aim at delaying this cascade and may thus reduce both the health and economic burden of such lesions. This study compared the costs and effectiveness of alternative treatments of proximal caries lesions.

Methods

A Markov-process model was used to simulate the events following the treatment of a proximal posterior lesion (E2/D1) in a 20-year-old patient in Germany. We compared three interventions (non-invasive; micro-invasive using resin infiltration; invasive using composite restoration). We calculated the risk of complications of initial and possible follow-up treatments and modelled time-dependent non-linear transition probabilities. Costs were calculated based on item-fee catalogues in Germany. Monte-Carlo-microsimulations were performed to compare cost-effectiveness of non- versus micro-invasive treatment and to analyse lifetime costs of all three treatments.

Results

Micro-invasive treatment was both more costly and more effective than non-invasive therapy, with ceiling-value-thresholds for willingness-to-pay between 16.73 € for E2 and 1.57 € for D1 lesions. Invasive treatment was the most costly strategy. Calculated costs and effectiveness were sensitive to lesion stage, patient’s age, discounting rate and assumed initial treatment costs.

Conclusions

Non- and micro-invasive treatments have lower long-term costs than invasive therapy of proximal lesions. Micro-invasive therapy had the highest cost-effectiveness for treating D1 lesions in young patients. Decision makers with a willingness-to-pay over 16.73 € and 1.57 € for E2 and D1 lesions, respectively, will find micro-invasive treatment more cost-effective than non-invasive therapy.  相似文献   

18.

Aim

To investigate the clinical application of a technique for patient set-up verification in breast cancer radiotherapy based on a 3D surface image registration system.

Background

Accurate and reproducible patient set-up is a prerequisite to correctly deliver fractionated radiotherapy. Various approaches are available to verify and correct patient setup for 3D image acquisition in a radiation treatment room.

Materials and methods

The study analyzed the setup reproducibility of 15 patients affected by breast cancer and candidates for conformal radiotherapy by using the AlignRT system (VisionRT, London, UK). At the initial setup, electronic portal imaging device (EPID) images were compared with Digitally Reconstructed Radiographs (DRRs) and a reference three-dimensional (3D) surface image was obtained by AlignRT. Surface images were acquired prior to every subsequent setup procedure. The systematic and random errors along longitudinal and vertical directions were measured and compared for the two systems.

Results

The procedure for surface registration, image acquisition and comparison with the reference image took less than 1 min on average. The T test for systematic error showed no significant difference between the 2 verification systems along the longitudinal (p = 0.69) and vertical (p = 0.67) axes. The T-test for random error showed a significant difference between the 2 systems along the vertical axis (p = 0.05).

Conclusion

AlignRT is fast, simple, non-invasive and seems to be reliable in detecting patient setup errors. Our results suggest that it could be used to assess the setup reproducibility for breast cancer patients.  相似文献   

19.

Purpose

Dual-energy (DE) radiographic imaging improves tissue discrimination by separating soft from hard tissues in the acquired images. This study was to establish a mathematic model of DE imaging based on intrinsic properties of tissues and quantitatively evaluate the feasibility of applying the DE imaging technique to tumor localization in radiotherapy.

Methods

We investigated the dependence of DE image quality on the radiological equivalent path length (EPL) of tissues with two phantoms using a stereoscopic x-ray imaging unit. 10 lung cancer patients who underwent radiotherapy each with gold markers implanted in the tumor were enrolled in the study approved by the hospital''s Ethics Committee. The displacements of the centroids of the delineated gross tumor volumes (GTVs) in the digitally reconstructed radiograph (DRR) and in the bone-canceled DE image were compared with the averaged displacements of the centroids of gold markers to evaluate the feasibility of using DE imaging for tumor localization.

Results

The results of the phantom study indicated that the contrast-to-noise ratio (CNR) was linearly dependent on the difference of EPL and a mathematical model was established. The objects and backgrounds corresponding to ΔEPL less than 0.08 are visually indistinguishable in the bone-canceled DE image. The analysis of patient data showed that the tumor contrast in the bone-canceled images was improved significantly as compared with that in the original radiographic images and the accuracy of tumor localization using the DE imaging technique was comparable with that of using fiducial makers.

Conclusion

It is feasible to apply the technique for tumor localization in radiotherapy.  相似文献   

20.

Purpose

To evaluate the displacement of the central ocular surface during non-contact tonometry with and without soft contact lenses and determine the factors associated with the displacement of the central ocular surface and intraocular pressure (IOP) reading changes caused by wearing soft contact lenses (CLs).

Methods

One eye each in 21 subjects was studied. The cornea was photographed using a high-speed camera at 5,000 frames/sec during non-contact tonometry without contact lenses (NCL), with -5.0 diopters (D), -0.5 D and +5.0 D CL. The displacement of the ocular surface and the factors affecting displacement at the IOP reading and maximum displacement time were investigated.

Results

The IOP readings while wearing +5 D CL were significantly higher than those obtained while wearing -5 D CL. The ocular surface displacement between +5 D CL and other groups were significantly different. A significant positive correlation was found between the ocular surface displacement of subjects at the IOP reading time and the IOP obtained with the non-contact tonometer. A significant negative correlation was found between the ocular surface curvature and the IOP obtained using the non-contact tonometer. The radius of curvature of the ocular surface affected the displacement during the IOP reading and maximum displacement time.

Conclusions

Our results indicate that soft contact lens use changes the ocular surface behavior and IOP readings during non-contact tonometry. The radius of curvature of the eye affects the ocular surface displacement and IOP readings in this situation.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号