首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 6 毫秒
1.
The interaction of forces that produce chest wall motion and lung volume change is complex and incompletely understood. To aid understanding we have developed a simple model that allows prediction of the effect on chest wall motion of changes in applied forces. The model is a lever system on which the forces generated actively by the respiratory muscles and passively by impedances of rib cage, lungs, abdomen, and diaphragm act at fixed sites. A change in forces results in translational and/or rotational motion of the lever; motion represents volume change. The distribution and magnitude of passive relative to active forces determine the locus and degree of rotation and therefore the effect of an applied force on motion of the chest wall, allowing the interaction of diaphragm, rib cage, and abdomen to be modeled. Analysis of moments allow equations to be derived that express the effect on chest wall motion of the active component in terms of the passive components. These equations may be used to test the model by comparing predicted with empirical behavior. The model is simple, appears valid for a variety of respiratory maneuvers, is useful in interpreting relative motion of rib cage and abdomen and may be useful in quantifying the effective forces acting on the rib cage.  相似文献   

2.
A respiratory pump is described which is controlled by compressed air and contains no mechanical moving parts, neither a motor nor a piston. It can function on a self-adjusting rhythm or can be regulated externally (for example by the discharge of a phrenic nerve).  相似文献   

3.
4.
5.
This extracorporeal insulin infuser has been designed to be compact, simple to operate, and suitable either for clinical investigations of insulin-dependent diabetes mellitus or for long term treatment of the condition. A syringe driver of unconventional design is used, and the syringe will be available prefilled with insulin, specially formulated at standard strength for long term infusion. The device is electronically controlled to give variable rates of basal infusion, preset by switch and supplemented by bolus infusions demanded by pushbotton prior to meals. Sufficient insulin is carried in the syringe to meet the needs of most diabetics for at least a week without refilling, and the battery life is commensurately long. Signalling of the mealtime dose regime, and of alarm and failure conditions is by audible means. Insulin will most commonly be delivered subcutaneously, though other routes are possible.  相似文献   

6.
7.
8.
9.
10.
We describe a servo-controlled piston pump driven by a stepping motor. The analogue controller is a single non-linear second-order feedback loop with adjustable speed and acceleration limits. This system, designed to simulate slowly-moving active and non-linear systems, can be used as a low (0–6.5 litre s−1) flow volume generator in calibration procedures.  相似文献   

11.
12.
Ascites, a complicating feature of many diseases of the liver and peritoneum, commonly causes dyspnea. The mechanism of this symptom, however, is uncertain. In the present study, progressively increasing ascites was induced in anesthetized dogs, and the hypothesis was initially tested that ascites increases the impedance on the diaphragm and, so, adversely affects the lung-expanding action of the muscle. Ascites produced a gradual increase in abdominal elastance and an expansion of the lower rib cage. Concomitantly, the caudal displacement of the diaphragm and the fall in airway opening pressure during isolated stimulation of the phrenic nerves decreased markedly; transdiaphragmatic pressure during phrenic stimulation also decreased. To assess the adaptation to ascites of the respiratory system overall, we subsequently measured the changes in lung volume, the arterial blood gases, and the electromyogram of the parasternal intercostal muscles during spontaneous breathing. Tidal volume and minute ventilation decreased progressively as ascites increased, leading to an increase in arterial PCO2 and parasternal intercostal inspiratory activity. It is concluded that 1) ascites, acting through an increase in abdominal elastance and an expansion of the lower rib cage, impairs the lung-expanding action of the diaphragm; 2) this impairment elicits a compensatory increase in neural drive to the inspiratory muscles, but the compensation is not sufficient to maintain ventilation; and 3) dyspnea in this setting results in part from the dissociation between increased neural drive and decreased ventilation.  相似文献   

13.
A new type of blood pump was tested in calves for 6 hours. The pump consists of a rigid housing with a trochoidal internal surface, an inlet and outlet, and two lateral walls. A two-corner piston rotating on an eccentric shaft, describes a trochoidal path, thus creating a gap seal, the gap measuring a constant 10-35 microns. The pump is driven by a watercooled DC motor. For right ventricular assist, a cannula is inserted into the right ventricle through the right atrium, and into the left ventricle for left ventricular assists. From a total of 10 experiments, two left ventricular assists, two right ventricular assists, and three biventricular assists were evaluated. The pump produced a pulsatile flow of 31 at 70 rpm. Energy requirements were 2.19 watts for left, 2.06 for right, and 7.26 for biventricular assists. Plasma hemoglobin remained as low as 10 mg/dl during monoventricular, and increased during biventricular assists to 20 mg/dl after 3 hours, and returned to 16 mg/dl after 6 hours. From these preliminary results it is concluded that this new rotary blood pump may be suitable as a circulatory assist device.  相似文献   

14.
15.
Activity of respiratory pump and upper airway muscles during sleep onset   总被引:9,自引:0,他引:9  
Ventilationdecreases at sleep onset. This change is initiated abruptly at -electroencephalographic transitions. The aim of this study was todetermine the contributions of reduced activity in respiratory pumpmuscles and upper airway dilator muscles to this change. Surfaceelectromyograms over the diaphragm (Di) and intercostal muscles andfine-wire intramuscular electrodes in genioglossus (GG) and tensorpalatini (TP) muscles were recorded in nine healthy young men. It wasshown that phasic Di and both phasic and tonic TP activities were lowerduring  than during  activity. Breath-by-breath analysis of thechanges at - transitions during the sleep-onset period showed anumber of changes. At - transitions, phasic activity of Di,intercostal, and GG muscles fell and rose again, and phasic and tonicactivities of TP fell and remained at low levels during . With astate transition from  to , the phasic and tonic activities ofthe Di, GG, and TP increased dramatically. It is now clear that thefall in ventilation that occurs with sleep is related to a fall inactivities of both upper airway dilator muscles and respiratory pumpmuscles.

  相似文献   

16.

Background

Several strategies and devices have been designed to protect health care providers from acquiring transmissible respiratory diseases while providing care. In modulating the physical characteristics of the respiratory secretions to minimize the aerosolization that facilitates transmission of airborne diseases, a fundamental premise is that the prototype drugs have no adverse effect on the first line of respiratory defense, clearance of mucus by ciliary action.

Methods

To assess and demonstrate the primary mechanism of our mucomodulators (XLs), we have built our evidence moving from basic laboratory studies to an ex-vivo model and then to an in-vivo large animal model. We exposed anesthetized dogs without hypersecretion to different dose concentrations of aerosolized XL "B", XL "D" and XL "S". We assessed: cardio-respiratory pattern, tracheal mucus clearance, airway patency, and mucus viscoelastic changes.

Results

Exposure of frog palate mucus to XLs did not affect the clearance of mucus by ciliary action. Dogs maintained normal cardio-respiratory pattern with XL administration. Tracheal mucociliary clearance in anesthetized dogs indicated a sustained 40% mean increase. Tracheal mucus showed increased filance, and there was no mucus retention in the airways.

Conclusion

The ex-vivo frog palate and the in-vivo mammalian models used in this study, appear to be appropriate and complement each other to better assess the effects that our mucomodulators exert on the mucociliary clearance defence mechanism. The physiological function of the mucociliary apparatus was not negatively affected in any of the two epithelial models. Airway mucus crosslinked by mucomodulators is better cleared from an intact airway and normally functioning respiratory system, either due to enhanced interaction with cilia or airflow-dependent mechanisms. Data obtained in this study allow us to assure that we have complied with the fundamental requirement criteria established in the initial phase of developing the concept of mucomodulation: Can we modulate the physical characteristics of the respiratory secretions to reduce aerosolization without affecting normal mucociliary clearance function, or even better improving it?  相似文献   

17.
Roles of the respiratory Na+ pump in bioenergetics of Vibrio alginolyticus   总被引:3,自引:0,他引:3  
Bioenergetic characteristics of Na+ pump-defective mutants of a marine bacterium Vibrio alginolyticus were compared with those of the wild type and revertant. Generation of membrane potential and motility at pH 8.5 in the mutants were completely inhibited by a proton conductor, carbonylcyanide m-chlorophenylhydrazone, whereas those in the wild type or revertant were resistant to the inhibitor. Motility and amino acid transport were driven by the electrochemical potential of Na+ not only in the wild type or revertant but also in the mutants. In the absence of the proton conductor, motility and amino acid transport of the mutants did not significantly differ from those of the wild type or revertant even at pH 8.5, where the Na+ pump has maximum activity. Therefore, the electrochemical potential of Na+ in the mutants seemed to be maintained at a normal level by a respiration-dependent H+ pump and Na+/H+ antiporter. On the other hand, growth of the mutants became defective as the medium pH increased, especially on minimal medium. These results indicate that the Na+ pump is an important energy-generating mechanism when nutrients are limited at alkaline pH.  相似文献   

18.
19.
20.
Fetal heart rate (FHR) monitoring forms the basis of routine fetal assessment, particularly short-term variability in the interbeat interval which can be difficult to interpret. Respiratory sinus arrhythmia (RSA), the change in heart rate in response to breathing, contributes to short-term variability, and the presence of RSA in utero may reflect the functional integrity of the central nervous system. This paper describes the use of Doppler ultrasound to derive the required measures of fetal heart rate and fetal breathing movements and spectral analysis to identify RSA. Cases are presented to illustrate the results obtained both in the presence and absence of RSA.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏