首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Quenching effects of bergenin, based on the electrochemiluminescence (ECL) of the tris(2,2′‐bipyridyl)‐ruthenium(II) (Ru(bpy)32+)/tri‐n‐propylamine (TPrA) system in aqueous solution, is been described. The quenching behavior can be observed with a 100‐fold excess of bergenin over Ru(bpy)32+. In the presence of 0.1 m TPrA, the Stern–Volmer constant (KSV) of the ECL quenching is as high as 1.16 × 104 M?1 for bergenin. The logarithmic plot of the inhibited ECL versus logarithmic plot of the concentration of bergenin was linear over the range 3.0 × 10?6–1.0 × 10?4 mol/L. The corresponding limit of detection was 6.0 × 10?7 mol/L for bergenin (S/N = 3). In the mechanism of quenching it is believed that the competition of the active free radicals between Ru(bpy)32+/TPrA and bergenin was the key factor for the ECL inhibition of the system. Photoluminescence, cyclic voltammetry, coupled with bulk electrolysis, supports the supposition mechanism of the Ru(bpy)32+/TPrA–bergenin system. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

2.
This work reports for the first time a potential‐based nano‐electrochemiluminescent (ECL) pH sensor, using anatase TiO2 nanocrystals (NCs) as the ECL probe. The first ECL peak potential of the TiO2 NCs shifted negatively with increasing pH, showing a linear range from −0.47 V (vs Ag/AgCl) at pH 3 to −1.06 V at pH 10. This phenomenon was attributed to the absorption of ‘potential‐determining ions’ of OH on the surface of TiO2 NCs, leading to larger impedance of the electron injection. Other common ‘potential‐determining ions’, such as phosphate, induced a slight potential shift of 0.03 V at a concentration of 0.1 M. Using urease as an enzyme model, a urea biosensor was developed by the simultaneous modification of urease and TiO2 NCs on indium–tin oxide (ITO) electrodes. The biosensor, measured on the basis of the pH increase caused by the enzyme catalysis reaction, had a linear range of 0.01–2.0 mM, with a potential shift of 0.175 V. The as‐prepared pH sensor, which has simple construction procedures and acceptable sensitivity and selectivity, may provide new avenues for the construction of ECL bioanalytical methodologies. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

3.
To develop conducting organic polymers (COPs) as luminescent sensors for determination of toxic heavy metals, a new benzene sulfonic acid‐doped polypyrrole (PPy‐BSA) thin film was electrochemically prepared by cyclic voltammetry (CV) on flexible indium tin oxide (ITO) electrode in aqueous solution. PPy‐BSA film was characterized by FTIR spectrometry, X‐ray photoelectron spectroscopy (XPS) and scanning electron microscopy (SEM). The optical properties of PPy‐BSA were investigated by ultraviolet (UV)‐visible absorption and fluorescence spectrometry in dimethylsulfoxide (DMSO) diluted solutions. PPy‐BSA fluorescence spectra were strongly quenched upon increasing copper(II) ion (Cu2+) and lead(II) ion (Pb2+) concentrations in aqueous medium, and linear Stern–Volmer relationships were obtained, which indicated the existence of a main dynamic fluorescence quenching mechanism. BSA‐PPy sensor showed a high sensitivity for detection of both metallic ions, Cu2+ and Pb2+, with very low limit of detection values of 3.1 and 18.0 nM, respectively. The proposed quenching‐fluorimetric sensor might be applied to the determination of traces of toxic heavy metallic ions in water samples.  相似文献   

4.
A chemically modified electrode constructed by incorporating N,N(')-bis(salicylidene)-1,2-phenylenediaminocobalt(II) into carbon-paste matrix was used as a sensitive electrochemical sensor for detection of cysteine. The resulting electrode exhibits catalytic properties for the electrooxidation of cysteine and lowers the overpotential for the oxidation of this compound. The faster rate of electron transfer results in a near-Nernstian behavior of the modified electrode and makes it a suitable potentiometric and voltammetric sensor for the fast and easy determination of cysteine. A linear response in concentration range from approximately 2 microM to 0.01 M was obtained with a detection limit of 1 microM for the potentiometric detection of cysteine. The modified electrode was also used for the amperometric and differential pulse voltammetric determination of cysteine and the results were compared with those of the potentiometric method.  相似文献   

5.
Quantitative electrochemiluminescence (ECL) detection of a model protein, bovine serum albumin (BSA) was achieved via biotin–avidin interaction using an avidin-based sensor and a well-developed ECL system of tris(2,2′-bipyridine) ruthenium(II) derivative as label and tri-n-propylamine (TPA) as coreactant. To detect the protein, avidin was linked to the glassy carbon electrode through passive adsorptions and covalent interaction with carboxylate-terminated carbon nanotubes that was used as binder to immobilize avidin onto the electrode. Then, biotinylated BSA tagged with tris(2,2′-bipyridine) ruthenium(II) label was attached to the prepared avidin surface. After binding of BSA labeled with tris(2,2′-bipyridine) ruthenium(II) derivative to the surface-immobilized avidin through biotin, ECL response was generated when the self-assembled modified electrode was immersed in a TPA-containing electrolyte solution. Such double protein labeling protocol with a biotin label for biorecognition and ruthenium label for ECL detection facilitated the detection of protein compared to the classical double antibody sandwich format. The ECL intensity was linearly proportional to the feed concentration of BSA over two orders of magnitude in the range of 15 nM to 7.5 μM. The detection limit was estimated to be 1.5 nM. Further application to the lysozyme analysis was carried out to validate the present approach for an effective and favorable protocol for the quantitative detection of proteins. The dynamic range of lysozyme was from 0.001 g L−1 to 0.1 g L−1 and the detection limit was 0.1 mg L−1. Electrochemical impedance and cyclic voltammetric measurements along with some necessary control experiments were conducted to characterize the successful formation of self-assembled modified electrodes and to grant the whole detection process.  相似文献   

6.
Dai H  Liu F  Gao Q  Fu T  Kou X 《Luminescence》2011,26(6):523-530
An intramolecular charge transfer (ICT) fluorescent sensor 1 using a dansyl moiety as the fluorophore and an azathia-crown ether as the receptor was designed, synthesized and characterized. The ions-selective signaling behaviors of the sensor 1 were investigated in CH(3) CN-H(2) O (1:1, v/v) by fluorescence spectroscopy. It exhibited remarkable fluorescence quenching upon addition of Hg(2+), which was attributed to the 1:1 complex formation between 1 and Hg(2+), while other selected metal ions induced basically no spectral changes. The sensor 1 showed a rapid and linear response towards Hg(2+) in the concentration range from 5.0 × 10(-7) to 1.0 × 10(-5) mol L(-1) with the detection limit of 1.0 × 10(-7) mol L(-1). Furthermore, the whole process could be carried out in a wide pH range of 2.0-8.0 and was not disturbed by other metal ions. Thus, the sensor 1 was used for practical determination of Hg(2+) in different water samples with satisfactory results.  相似文献   

7.
A simple and sensitive electrochemiluminescence (ECL) method for the determination of etamsylate has been developed by coupling an electrochemical flow‐through cell with a tris(2,2'‐bipyridyl)ruthenium(II) (Ru(bpy)32+)–Nafion‐modified carbon electrode. It is based on the oxidized Ru(bpy)32+ on the electrode surface reacting with etamsylate and producing an excellent ECL signal. Under optimized experimental conditions, the proposed method allows the measurement of etamsylate over the range of 8–1000 ng/mL with a correlation coefficient of r = 0.9997 (n = 7) and a limit of detection of 1.57 ng/mL (3σ), the relative standard deviation (RSD) for 1000 ng/mL etamsylate (n = 7) is 0.96%. The immobilized Ru(bpy)32+ carbon paste electrode shows good electrochemical and photochemical stability. This method is rapid, simple, sensitive and has good reproducibility. It has been successfully applied to the determination of the studied etamsylate in pharmaceutical preparations with satisfactory results. The possible ECL reaction mechanism has also been discussed. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

8.
In this work, a highly sensitive biosensor for detecting cadmium ions (Cd2+) was developed based on a Cd2+-specific DNA aptamer and a hybridization chain reaction (HCR). The Cd2+ aptamer (named S0) was used to recognize Cd2+ and trigger the HCR. Without Cd2+, S0 initiated the HCR to form long nicked dsDNA structures to quench the fluorescence. Then, Cd2+ could bind with S0 to block HCR to recover fluorescence. This biosensor had high sensitivity with a detection limit of 0.36 nM and a linear range from 0 to 10 nM. Moreover, it showed a satisfactory selectivity and recovery rates.  相似文献   

9.
Based on the strong enhancement effect of procaterol hydrochloride on the electrochemiluminescence (ECL) of Ru(bpy)32+ (bpy = 2,2′‐bipyridine) in an alkaline H3PO4–NaOH buffer solution on a bare Pt electrode, a simple, rapid and sensitive method was developed for the determination of procaterol hydrochloride. The optimum conditions for the enhanced ECL have been developed in detail in this work. Under optimum conditions, the logarithmic ECL enhancement vs. the logarithmic concentration of procaterol hydrochloride is linear over a wide concentration range of 2.0 × 10?7 to 2.0 × 10?4 M (r =  0.9976), with a limit of detection of 1.1 × 10?8 M (S/N =  3), and a relative standard deviation of 2.1% (n =  7, c =  5.0 × 10?6 M). The proposed method was applied to the determination of this drug in tablets with recoveries of 89.7%–98.5%. In addition, a possible mechanism for the enhanced ECL of Ru(bpy)32+, which is caused by ProH, has also been proposed.  相似文献   

10.
A tris(2,2‐bipyridyl)ruthenium(II) (Ru(bpy)32+)‐based electrochemiluminescence (ECL) detection coupled with capillary electrophoresis (CE) method has been established for the sensitive determination of ephedrine for the first time. Under the optimized conditions [ECL detection at 1.15 V, 25 mmol/L phosphate buffer solution (PBS), pH 8.0, as running buffer, separation voltage 12.5 kV, 5 mmol/L Ru(bpy)32+ with 60 mmol/L PBS, pH 8.5, in the detection cell] linear correlation (r = 0.9987) between ECL intensity and ephedrine concentration was obtained in the range 6.0 × 10–8–6.0 × 10–6 g/mL. The detection limit was 4.5 × 10–9 g/mL (S:N = 3). The developed method was successfully applied to the analysis of ephedrine in human urine and the investigation of its interactions with three proteins, including bovine serum albumin (BSA), cytochrome C (Cyt‐C) and myoglobin (Mb). The number of binding sites and the binding constants between ephedrine and BSA, Cyt‐C and Mb were 8.52, 12.60, 10.66 and 1.55 × 104 mol/L, 6.58 × 103 mol/L and 1.59 × 104 mol/L, respectively. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

11.
桔青毒素(citrinin,CTN)是以玉米、谷物、奶酪等为主要成分的食品和动物饲料中常见的、由桔青霉菌产生的酮类真菌毒素,可引起人和动物的慢性中毒或癌症,一直缺少灵敏的快速检测方法。本文通过指数富集适体系统进化技术(简称SELEX)对可能与CTN结合的特异性适体进行了筛选,经过15轮循环,得到17条适体。通过二级结构分析、亲和力检测发现适体13(Apt-13)对CTN有较好的亲和度,解离常数Kd为0.06μmol/L。进一步利用非荧光标记染料PicoGreen,利用其与双链DNA结合的原理,建立了桔青毒素非标记荧光检测方法,30min完成检测,最低检测限达到国家标准(50ppb)且与其他毒素无交叉反应。本研究建立的基于适体的桔青毒素检测技术成本低,可以替代传统的基于抗体的检测方法,为霉菌毒素的精准检测技术的开发提供了实验证据。  相似文献   

12.
《Luminescence》2002,17(2):117-122
The electrogenerated chemiluminescence of Ru(bpy)32+/C2O42? system on a pre‐polarized Au electrode was studied using a potential‐resolved electrochemiluminescence (PRECL) method. Two anodic ECL peaks were observed at 1.22 V (vs. SCE) (EP1), 1.41 V (vs. SCE) (EP2), respectively. The effects of the concentration of oxalate and Ru(bpy)32+, adsorbed sulphur, CO2, O2, pH of the solution and pretreatment of the Au electrode on the two PRECL peaks were examined. The surface state of the pre‐oxidized gold electrode was also studied using the X‐ray photoelectron spectroscopy (XPS) technique. Moreover, comparative studies on i–E and I–E curves were carried out and a possible mechanism involving both the catalytic and the direct electro‐oxidation pathways was proposed for the ECL of Ru(bpy)32+/C2O42? system. EP1 is attributed to the Ru(bpy)32/3+ reaction catalysed by C2O42? to generate Ru(bpy)32+*. EP2 is likely because C2O42? was oxidized at the electrode to form CO2, followed by reaction with Ru(bpy)33+ to generate Ru(bpy)32+*. Copyright © 2002 John Wiley & Sons, Ltd.  相似文献   

13.
Cysteamine (CA)‐capped CdTe quantum dots (QDs) (CA–CdTe QDs) were prepared by the reflux method and utilized as an efficient nano‐sized fluorescent sensor to detect mercury (II) ions (Hg2+). Under optimum conditions, the fluorescence quenching effect of CA–CdTe QDs was linear at Hg2+ concentrations in the range of 6.0–450 nmol/L. The detection limit was calculated to be 4.0 nmol/L according to the 3σ IUPAC criteria. The influence of 10‐fold Pb2+, Cu2+ and Ag+ on the determination of Hg2+ was < 7% (superior to other reports based on crude QDs). Furthermore, the detection sensitivity and selectivity were much improved relative to a sensor based on the CA–CdTe QDs probe, which was prepared using a one‐pot synthetic method. This CA–CdTe QDs sensor system represents a new feasibility to improve the detection performance of a QDs sensor by changing the synthesis method. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

14.
Poly(sulfosalicylic acid) and single-stranded DNA composite (PSSA–ssDNA)-modified glassy carbon electrode (GCE) was prepared by electropolymerization and then successfully used to simultaneously determine adenine (A), guanine (G), and thymine (T). The characterization of electrochemically synthesized PSSA–ssDNA film was investigated by scanning electron microscopy (SEM) and electrochemical impedance spectroscopy (EIS). The modified electrode exhibited enhanced electrocatalytic behavior and good stability for the simultaneous determination of A, G, and T in 0.1 M phosphate buffer solution (PBS, pH 7.0). Well-separated voltammetric peaks were obtained among A, G, and T presented in the analyte mixture. Under the optimal conditions, the peak currents for A, G, and T increased linearly with the increase of analyte mixture concentration in the ranges of 6.5 × 10−8 to 1.1 × 10−6, 6.5 × 10−8 to 1.1 × 10−6, and 4.1 × 10−6 to 2.7 × 10−5 M, respectively. The detection limits (signal/noise = 3) for A, G, and T were 2.2 × 10–8, 2.2 × 10–8, and 1.4 × 10–6 M, respectively.  相似文献   

15.
Peng Wang  Guoyi Zhu 《Luminescence》2000,15(4):261-265
Two novel electrochemiluminescent labels, bis(2,2′-bipyridine)[5-(3-carboxylic acid-propionamido)-1,10-phenanthroline]ruthenium(II) hexafluorophosphate dihydrate and bis(2,2′-bipyridine)[5-(4-carboxylic acid-butanamido)-1,10-phenanthroline]ruthenium(II) hexafluorophosphate dihydrate, were synthesized and confirmed by IRelemental analysis, and 1H-NMR spectra were completely assigned using the 1H-1H COSY technique. Cyclic voltammograms with different scan rates showed quasi-reversible electrochemical behaviour of the two Ru (II) complex labels in MeCN solution. Electronic absorption, photoluminescence and electrochemiluminescence of Ru(II) complexes were also characterized. Copyright © 2000 John Wiley & Sons, Ltd.  相似文献   

16.
An amperometric biosensor based on malate quinone oxidoreductase (MQO) was developed for monitoring of the malolactic fermentation of wines. Screen-printed electrodes coupled with appropriate mediators were used as transducers for this novel biosensor. MQO was immobilized by physical entrapment in a photo-cross-linkable poly(vinyl alcohol) polymer (PVA-SbQ) on the surface of the working electrode. Several electrochemical mediators were studied in order to lower the applied potential and minimise the matrix effects. Among them, 2,6-dichlorophenol indophenol (DPIP) and phenazine methosulfate (PMS) were chosen for further development. The working conditions (mediator concentration, applied potential and pH) were optimised for both DPIP and PMS. Detection limits for both types of biosensors were of 5 μM malic acid. Sensitivities obtained for the linear part of the calibration curve were 0.85 and 1.7 mA/M for the biosensors based on DPIP and PMS, respectively. Interferences due to non-specific oxidations were shown to be negligible when using PMS as mediator.  相似文献   

17.
The immobilization strategy of cell‐specific aptamers is of great importance for studying the interaction between a cell and its aptamer. However, because of the difficulty of studying living cell, there have not been any systematic reports about the effect of immobilization strategies on the binding ability of an immobilized aptamer to its target cell. Because atomic force spectroscopy (AFM) could not only be suitable for the investigation of living cell under physiological conditions but also obtains information reflecting the intrinsic properties of individuals, the effect of immobilization strategies on the interaction of aptamer/human hepatocarcinoma cell Bel‐7404 was successively evaluated using AFM here. Two different immobilization methods, including polyethylene glycol immobilization method and glutaraldehyde immobilization method were used, and the factors, such as aptamer orientation, oligodeoxythymidine spacers and dodecyl spacers, were investigated. Binding events measured by AFM showed that a similar unbinding force was obtained regardless of the change of the aptamer orientation, the immobilization method, and spacers, implying that the biophysical characteristics of the aptamer at the molecular level remain undisturbed. However, it showed that the immobilization orientation, immobilization method, and spacers could alter the binding probability of aptamer/Bel‐7404 cell. Presumably, these factors may affect the accessibility of the aptamer toward its target cell. These results may provide valuable information for aptamer sensor platforms including ultrasensitive biosensor design. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

18.
Molecularly imprinted polymer‐modified glassy carbon electrode (GCE)‐based electrochemical sensor is prepared using the electropolymerization of aniline in the presence of melamine (MA) as a template. In this work, the advantages of molecularly imprinted conducting polymers (MICPs) and electroanalytical methods were combined to obtain an electronic device with better performances. The sensor performance was evaluated by cyclic voltammetry (CV) and square wave voltammetry (SWV) with the linear range of 0.6‐16 × 10?9M, quantification limit of 14.9 × 10?10M, and detection limit of 4.47 × 10?10M (S/N = 3). The selectivity of the sensor was tested in the presence of acetoguanamine (AGA), diaminomethylatrazine (DMT), casein, histidine, and glycine interfering molecules taken at the triple concentration with MA that demonstrated too small current response compared with that of the analyte indicating high specificity of the sensor towards the template. The sensor was successfully applied to determine MA in infant formula samples with significant recovery greater than 96% and relative standard deviation (RSD) less than 4.8%. Moreover, the good repeatability, recyclability, and stability make this sensor device promising for the real‐time monitoring of MA in different food stuffs.  相似文献   

19.
The structure, stability, and the IR, and EPR spectroscopic properties of bis(methoxyacetato)diaquo-copper(II) were studied both experimentally using FT-IR and theoretically using B3LYP/6-31G**, B3LYP/6-311G, BWP91/6-31G** methods. The same approaches were used to calculate the harmonic frequencies and to compare them to the experimental solid state values. The g-tensors are calculated using the NMR/GIAO computational method.  相似文献   

20.
Based on the fluorescence quenching of Terbium (III)‐sodium hexametaphosphate (Tb/SHMP) chelates in the presence chromate (III), a sensitive fluorimetric method was developed for the determination of trace amounts of chromium (III) in aqueous solutions. Under the optimum conditions, the linear calibration graph was obtained (R = 0.996). The linear range and detection limit of Cr (III) were 7.69 × 10?7 to 1.15 × 10?4 mol L?1 and 4.50 × 10?7 mol L?1, respectively. The proposed method had a wider linear range and was proved to be very sensitive, rapid and simple. The method was applied successfully to the determination of chromium (III) in the synthetic samples and real water samples. Moreover, the reaction mechanism was discussed through the fluorescence lifetime and proved to be dynamic quenching behavior. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号