首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The biological loading of viable, cultivable airborne microbes (heterotrophic bacteria, actinobacteria and fungi) in 6 size fractions as well as the three different fractions of respirable particulate matter (PM1, PM2.5 and PM10) and their relationship to meteorological conditions were studied in the ambient air due to health-related interests. An Andersen six stage viable particle impactor and a MAS 100 sampler were used for microbial measurements. 82 measurements were performed at three different periods (41 days) at a suburban, residential site in the city of Chania (Crete, Greece) during the period from April 2008 to June 2009. The concentrations of the viable, cultivable airborne microbes (bioaerosols) as well as of the PM1, PM2.5 and PM10 were highly variable during the whole measurement period. Among the airborne microbes, fungi presented the most abundant taxonomic group in the ambient air. A characteristic profile of the mean size distribution of biological loading in different PM fractions was obtained for every measured microbial taxonomic group. Although, the highest concentrations of the airborne fungi and actinobacteria were determined at aerodynamic diameters between 2.1 and 3.3 μm, a nearly equal distribution of the mean concentrations of the airborne heterotrophic bacteria was observed in the six different size fractions. However, two small maxima were observed at the airborne heterotrophic bacteria distribution, one at the fraction with aerodynamic diameters between 1.1 and 2.1 μm, and at other at the coarse fraction with aerodynamic diameter larger than 7 μm. A considerable part of the airborne microbes Cycloheximide per mL of growth medium of bacteriwere resistant to drugs. Between 10 and 40 % of the viable, cultivable airborne microbes were resistant to low concentrations of drugs (5–10 μg of Streptomycin or a or fungi, respectively). Furthermore, multiple linear regression of the data showed that the variation in fungi concentrations depends on the variation in PM10 mass concentration, PM1 number concentration, relative humidity and solar radiation. Likewise, the concentration of heterotrophic bacteria was found proportional to the values of relative humidity and fungal concentration, whereas was negatively correlated to the solar radiation.  相似文献   

2.

In recent years, monitoring of airborne bacteria and fungi concentrations has obtained increasing universal attraction not only for influences on ecological balance but also for evaluating their public health consequences. In this study, we aimed to investigate culturable airborne bacteria and fungi levels in different sites of Abadan, and their association with meteorological parameters and PM2.5 levels. Abadan is one of the most industrialized cities in the southwest of Iran where over the current decade has experienced lots of dust storm episodes. In total, 400 air samples were collected in 6 months (autumn and winter) using a single-stage viable Andersen cascade impactor for sampling airborne bacteria and fungi and portable DustTrak Aerosol Monitor 8520 for measuring PM2.5 concentrations and meteorological parameters. Microbial concentrations showed a significant difference between various sites over the study period with averages of 569.57?±?312.64 and 482.73?±?242.86 CFU/M3 for bacteria and fungi, respectively. The air temperature had a significant effect on the concentration of both airborne bacteria and fungi. A significant positive correlation between relative humidity and fungi but no correlation between relative humidity and bacteria concentrations were observed. The average airborne PM2.5 concentrations of all sites among the study period was 93.24?±?116.72 μg/m3. The atmospheric bacterial and fungal communities were strongly positively correlated with the ambient PM2.5 level. The levels of airborne bacteria and fungi along with PM2.5 in the air of the city were relatively higher than the recommended levels. Therefore, the best course of action is needed to control emission sources. Further studies are also needed to evaluate the clinical analysis of the health effects of exposure to these pollutants.

  相似文献   

3.
We conducted a study to investigate the characteristics and determinants of ambient bacteria in Taipei, Taiwan from August 2004 to March 2005. We monitored ambient culturable bacteria in Shin-Jhuang City, an urban area in the Taipei metropolitan areas, using duplicate Burkard Portable Air Samplers with R2A agar. The average concentration of total bacteria was 1,986 colony-forming units per cubic meter of air (CFU/m3) (median?=?780 CFU/m3) over the study period, with the highest level in autumn. Most bacterial taxa had similar seasonal variation, with higher concentrations in autumn and winter. During the study period, Gram negative rods and cocci were predominant. Multivariate analyses indicated that wind speed and wind direction significantly influenced ambient bacterial distribution. Temperature and relative humidity were also important environmental factors positively associated with ambient bacterial concentrations. We observed statistically significant relationships between ambient bacteria and air pollutants, including sulfur dioxide (SO2), ozone, particulate matter (aerodynamic diameter ≤10 μm (PM10)), methane and total hydrocarbons. The concentrations of methane and total hydrocarbons during the previous day were positively associated with total bacteria and Gram negative rods, respectively. Ozone level on the previous day had a negative relationship with Gram negative cocci. SO2 level with a 3-day lag was positively correlated with concentrations of both total bacteria and Gram negative cocci. In the future, more longitudinal studies are needed to confirm the relationships and possible mechanisms between ambient bacteria and meteorological factors, as well as to evaluate the ecological and health impacts of ambient bacteria.  相似文献   

4.
Ambient outdoor concentrations and size distributions of airborne microbial particles were measured approximately weekly for 2 years in a Washington, D.C., suburban area. The study objective was to characterize microbial air quality in the vicinity of a proposed sewage sludge composting facility. During the study, 379 samples were taken at 17 stations, using Andersen microbial samplers. Concentration ranges (in viable particles per cubic meter) were as follows: airborne mesophilic fungi, 0 to 7,220 with a geometric mean of 273; thermophilic fungi, 0 to 193 with a median of 2.1; Aspergillus fumigatus, 0 to 71 with a median of 1.0; aerobic bacteria, 4.2 to 1,640 with a geometric mean of 79; and fecal streptococci, 0 to 5.7 with a median of 0. No fecal coliforms were recovered. The potentially respirable fraction (less than 8 microns) averaged 34% for total bacteria, 56% for mesophilic fungi, 91% for thermophilic fungi, and 95% for A. fumigatus. The specific sampling location was not a major factor affecting microbial particle concentrations or size distributions. Conversely, the time of year was an important determinant of viable particle concentrations for all groups of microorganisms studied. The highest concentrations were observed in summer and fall, with significantly lower levels detected in winter. In general, the microbial data did not correlate with other variables, including weather conditions, measured in this study.  相似文献   

5.
Ambient outdoor concentrations and size distributions of airborne microbial particles were measured approximately weekly for 2 years in a Washington, D.C., suburban area. The study objective was to characterize microbial air quality in the vicinity of a proposed sewage sludge composting facility. During the study, 379 samples were taken at 17 stations, using Andersen microbial samplers. Concentration ranges (in viable particles per cubic meter) were as follows: airborne mesophilic fungi, 0 to 7,220 with a geometric mean of 273; thermophilic fungi, 0 to 193 with a median of 2.1; Aspergillus fumigatus, 0 to 71 with a median of 1.0; aerobic bacteria, 4.2 to 1,640 with a geometric mean of 79; and fecal streptococci, 0 to 5.7 with a median of 0. No fecal coliforms were recovered. The potentially respirable fraction (less than 8 microns) averaged 34% for total bacteria, 56% for mesophilic fungi, 91% for thermophilic fungi, and 95% for A. fumigatus. The specific sampling location was not a major factor affecting microbial particle concentrations or size distributions. Conversely, the time of year was an important determinant of viable particle concentrations for all groups of microorganisms studied. The highest concentrations were observed in summer and fall, with significantly lower levels detected in winter. In general, the microbial data did not correlate with other variables, including weather conditions, measured in this study.  相似文献   

6.
Limited data are currently available on the concentrations of airborne bacteria, fungi, and endotoxins in indoor environments. The levels of aerial bacteria and fungi were measured at several microenvironments within a well-ventilated residential apartment in Singapore including the living room, kitchen, bedroom, toilet, and at a workplace environment by sampling indoor air onto culture medium plates using the 6-stage Andersen sampler. Total microbial counts were determined by collecting the air samples in water with the Andersen sampler, staining the resultant extracts with a fluorescent dye, acridine orange, and counting the microbes using a fluorescent microscope. The levels of airborne endotoxins were also determined by sampling the airborne microorganisms onto 0.4?μm polycarbonate membrane filter using the MiniVol sampler at 5?l/min for 20?h with a PM2.5 cut-off device. The aerial bacterial and fungal concentrations were found to be in the ranges of 117–2,873?CFU/m3 and 160–1,897?CFU/m3, respectively. The total microbial levels ranged from 49,000 to 218,000?microbes/m3. The predominant fungi occurring in the apartment were Aspergillus and Penicillium while the predominant bacterial strains appeared to be Staphylococcus and Micrococcus. The average indoor endotoxin level was detectable in the range of 6–39?EU/m3. The amount of ventilation and the types of human activities carried out in the indoor environment appeared to be important factors affecting the level of these airborne biological contaminants.  相似文献   

7.
This study was conducted to evaluate the effects of transported Asian dust and other environmental parameters on the levels and compositions of ambient fungi in the atmosphere of northern Taiwan. We monitored Asian dust events in Taipei County, Taiwan from January 2003 to June 2004. We used duplicate Burkard portable air samplers to collect ambient fungi before, during, and after dust events. Six transported Asian dust events were monitored during the study period. Elevated concentrations of Aspergillus (A. niger, specifically), Coelomycetes, Rhinocladiella, Sporothrix and Verticillium were noted (p < 0.05) during Asian dust periods. Botryosporium and Trichothecium were only recovered during dust event days. Multiple regression analysis showed that fungal levels were positively associated with temperature, wind speed, rainfall, non-methane hydrocarbons and particulates with aerodynamic diameters ≤10 μm (PM10), and negatively correlated with relative humidity and ozone. Our results demonstrated that Asian dust events affected ambient fungal concentrations and compositions in northern Taiwan. Ambient fungi also had complex dynamics with air pollutants and meteorological factors. Future studies should explore the health impacts of ambient fungi during Asian dust events, adjusting for the synergistic/antagonistic effects of weather and air pollutants.  相似文献   

8.
Air artificially contaminated with increasing concentrations of benzene was treated in a laboratory scale compost-packed biofilter for 240 days with a removal efficiency of 81–100%. The bacterial community in the packing material (PM) at different heights of the biofilter was analysed every 60 days. Bacterial plate counts and ribosomal intergenic spacer analysis (RISA) of the isolated strains showed that the number of cultivable aerobic heterotrophic bacteria and the species diversity increased with benzene availability. Identification of the isolated species and the main bands in denaturing gradient gel electrophoresis (DGGE) profiles from total compost DNA during the treatment revealed that, at a relatively low volumetric benzene load (1.2≤VBL≤6.4 g m−3 PM h−1), besides low G+C Gram positive bacteria, originally present in the packing compost, bacteroidetes and β- and γ-proteobacteria became detectable in the colonising population. At the VBL value (24.8 g m−3 PM h−1) ensuring the maximum elimination capacity of the biofilter (20.1 g m−3 PM h−1), strains affiliated to the genus Rhodococcus dominated the microflora, followed by β-proteobacteria comprising the genera Bordetella and Neisseria. Under these conditions, more than 35% of the isolated strains were able to grow on benzene as the sole carbon source. Comparison of DGGE and automated RISA profiles of the total community and isolated strains showed that a complex bacterial succession occurred in the reactor in response to the increasing concentrations of the pollutant and that cultivable bacteria played a major role in benzene degradation under the adopted conditions.  相似文献   

9.
Short-term effects of ozone (O3) on phyllosphere fungi were studied by examining fungal populations from leaves of giant sequoia (Sequoiadendron giganteum (Lindl.) Buchholz) and California black oak (Quercus kelloggii Newb.). Chronic effects of both O3 and sulfur dioxide (SO2) were studied by isolating fungi from leaves of mature Valencia orange (Citrus sinensis L.) trees. In this chronic-exposure experiment, mature orange trees were fumigated in open-top chambers at the University of California, Riverside, for 4 years with filtered air, ambient air plus filtered air (1:1), ambient air, or filtered air plus SO2 at 9.3 parts per hundred million. Populations of Alternaria alternata (Fr.) Keissler and Cladosporium cladosporioides (Fres.) de Vries, two of the four most common fungi isolated from orange leaves, were significantly reduced by chronic exposure to ambient air. In the short-term experiments, seedlings of giant sequoia or California black oak were fumigated in open-top chambers in Sequoia National Park for 9 to 11 weeks with filtered air, ambient air, or ambient air plus O3. These short-term fumigations did not significantly affect the numbers of phyllosphere fungi. Exposure of Valencia orange trees to SO2 at 9.3 parts per hundred million for 4 years reduced the number of phyllosphere fungi isolated by 75% compared with the number from the filtered-air treatment and reduced the Simpson diversity index value from 3.3 to 2.5. A significant chamber effect was evident since leaves of giant sequoia and California black oak located outside of chambers had more phyllosphere fungi than did seedlings within chambers. Results suggest that chronic exposure to ambient ozone or SO2 in polluted areas can affect phyllosphere fungal communities, while short-term exposures may not significantly disturb phyllosphere fungi.  相似文献   

10.
Aims: We evaluated risks associated with diaper changing in Finnish kindergartens where children were using either modern disposable paper or reusable cloth diapers. Methods and Results: We determined enteric micro‐organisms and ammonia in diaper‐changing rooms in four kindergartens in autumn and winter in the ambient air. No coliphages were detected in the air. The numbers of faecal coliforms and enterococci in air were typically low regardless of whether the children used either paper or cloth diapers. Ammonia concentrations increased over the background level because of diaper changing. Conclusions: The numbers of bacteria or coliphages are not expected to pose any high air hygiene risks, and increased ammonia air concentrations are unlikely to impair the health of staff or children when diapers are changed in modern kindergartens. However, increased ammonia gas concentrations indicate that some other diaper‐related gas‐phase emissions should be studied to understand better diaper‐related health risks. Significance and Impact of the Study: Modern reusable cloth baby diapers and the modern paper baby diapers used in this study are equally safe with respect to risks from airborne virus, bacteria or ammonia.  相似文献   

11.
AIMS: To investigate the survival of cultivable bacteria in the tropical Bangpakong estuary (Eastern Thailand) under different salinities and light conditions. METHODS AND RESULTS: Dark and light microcosm experiments using membrane diffusion chambers were carried out under three different experimental conditions, namely (i) low salinity, (ii) progressive mixing with brackish water and (iii) fast mixing with high salinity water spiked with raw urban sewage. Faecal coliforms declined faster than faecal enterococci, as shown by survival T90 values ranging from 82.2 +/- 4.2 to 14.5 +/- 0.8 h and 97.5 +/- 0.4-20.6 +/- 1.2 h, respectively. The survival of freshwater heterotrophic bacteria was higher but variable (121.2 +/- 5.0-30.1 +/- 14.3 h), whereas that of heterotrophic marine bacteria was rather stable (81.5 +/- 4.2-44.6 +/- 2.5 h). CONCLUSIONS: Overall survival was higher in low salinities. Light had a further deleterious effect, since it accelerated the decay of faecal indicators, particularly in high salinities. Faecal enterococci had a higher resistance to environmental conditions compared with faecal coliforms. SIGNIFICANCE AND IMPACT OF THE STUDY: This study is relevant to the understanding of the behaviour of different faecal indicator bacteria and the optimization of sewage treatment plants aimed at the reduction and/or elimination of faecal load discharged into estuarine waters submitted to salinity variations.  相似文献   

12.
We have recently developed a new personal sampler and demonstrated its feasibility for detection of viable airborne microorganisms including bacteria, fungi and viruses. To accelerate the time-consuming analytical procedure involving 2-5 days of biological testing, we employed a real-time PCR protocol in conjunction with the personal sampler for collection of airborne viruses. The advantage of this approach is that if the presence of a particular pathogen in the air is detected by the PCR, the remaining collecting liquid can be further analysed by more time-consuming biological methods to estimate the number of airborne infectious/live microorganisms. As sampling of bioaerosols in natural environments is likely to be associated with substantial contamination by a range of microorganisms commonly existing in an ambient air, an investigation of the specificity of detection by targeted PCR analysis is required. Here we present the results of the study on the detection of Influenza virus in the ambient air contaminated with high concentrations of bacteria and fungi using real-time PCR protocol. The combined sampling PCR detection method was found to be fully feasible for the rapid ( approximately 2.5 h) and highly specific (no cross-reactivity) identification of the labile airborne virus in the air containing elevated concentrations of other microorganisms.  相似文献   

13.
Compost windrows for bioremediation of soil were built at a wood-preserving site contaminated with chlorophenols, polychlorinated dibenzo-p-dioxins (PCDDs), and polychlorinated dibenzofurans (PCDFs). Sampling of airborne particles during the mixing of the compost windrows found concentrations of PCDDs and PCDFs in different particle sizes. The congener distribution of PCDDs and PCDFs in the collected air particle fractions was similar to that in the compost windrows, and the level of PCDDs and PCDFs was 1000-fold higher than the atmospheric background values reported previously. Viable particle-sizing samplers and several selective growth media were used to enumerate bacteria and fungi in the airborne particles. From the collected air samples, 40 bacteria were isolated and identified. Among the isolated bacteria, 80% were Gram-positive and spore-forming. Two of the identified airborne bacteria, Pseudomonas aeruginosa and Bacillus cereus, may cause human disease and are classified in biological agent hazard group 2. The amounts of airborne fungi, molds, and yeasts were 1000 to 2000 colony-forming units (CFUs) per m3. The number of actinomycetes was up to 6-fold, and the number of bacteria was 2- to 20-fold compared to background values. The overall level of airborne bacteria (200 to 3500 CFUs per m3) was low compared to the level of bacteria (105 to 108 CFUs per m3) found when composting municipal waste.  相似文献   

14.
Fungi are ubiquitous in outdoor air, and their concentration, aerodynamic diameters and taxonomic composition have potentially important implications for human health. Although exposure to fungal allergens is considered a strong risk factor for asthma prevalence and severity, limitations in tracking fungal diversity in air have thus far prevented a clear understanding of their human pathogenic properties. This study used a cascade impactor for sampling, and quantitative real-time PCR plus 454 pyrosequencing for analysis to investigate seasonal, size-resolved fungal communities in outdoor air in an urban setting in the northeastern United States. From the 20 libraries produced with an average of ∼800 internal transcribed spacer (ITS) sequences (total 15 326 reads), 12 864 and 11 280 sequences were determined to the genus and species levels, respectively, and 558 different genera and 1172 different species were identified, including allergens and infectious pathogens. These analyses revealed strong relationships between fungal aerodynamic diameters and features of taxonomic compositions. The relative abundance of airborne allergenic fungi ranged from 2.8% to 10.7% of total airborne fungal taxa, peaked in the fall, and increased with increasing aerodynamic diameter. Fungi that can cause invasive fungal infections peaked in the spring, comprised 0.1–1.6% of fungal taxa and typically increased in relative abundance with decreasing aerodynamic diameter. Atmospheric fungal ecology is a strong function of aerodynamic diameter, whereby through physical processes, the size influences the diversity of airborne fungi that deposit in human airways and the efficiencies with which specific groups of fungi partition from outdoor air to indoor environments.  相似文献   

15.
Occurrence of airborne enteric bacteria in Mexico city   总被引:1,自引:0,他引:1  
Summary An investigation of microbial air quality in the area of the National Autonomous University of Mexico, located in the southern part of Mexico City, was conducted for one year. Ambient outdoor concentrations and size distribution of airborne bacteria were measured, 130 samples were taken at noon, using an Andersen 6 stage sampler, located 2 m above ground level. Concentration ranges and colony-forming units per cubic meter of air (CFU m–3) found, were as follows:14 to 12999 for total bacteria, No growth (NG) to 55 for coliform bacteria, NG to 11 for fecal coliform and NG to 10 for fecal Streptococci.Bacteria associated with the potentially respirable fraction (0.65 to 4.7 µm) averaged 37% and 9% for total bacteria and coliform bacteria respectively. In 23% of the samples, coliform bacteria were recovered, with higher incidences during dry season. The most common of these were:Escherichia coli (15%), followed bySerratia (13%) andEnterobacter (10%),The total bacteria correlated significatively (p<0.05) with the following parameters: particulate matter smaller than 10 µm (PM10) (r=0.40), total suspended particulates (TSP) (r=0.26), daily variation of temperature (r=0.18), and vapor pressure (r=–0.16). These relationships indicate that fecal soil pollution could affect air quality with potential health risks.  相似文献   

16.
Characterization of airborne bacteria at an underground subway station   总被引:1,自引:0,他引:1  
The reliable detection of airborne biological threat agents depends on several factors, including the performance criteria of the detector and its operational environment. One step in improving the detector's performance is to increase our knowledge of the biological aerosol background in potential operational environments. Subway stations are enclosed public environments, which may be regarded as potential targets for incidents involving biological threat agents. In this study, the airborne bacterial community at a subway station in Norway was characterized (concentration level, diversity, and virulence- and survival-associated properties). In addition, a SASS 3100 high-volume air sampler and a matrix-assisted laser desorption ionization-time of flight mass spectrometry-based isolate screening procedure was used for these studies. The daytime level of airborne bacteria at the station was higher than the nighttime and outdoor levels, and the relative bacterial spore number was higher in outdoor air than at the station. The bacterial content, particle concentration, and size distribution were stable within each environment throughout the study (May to September 2010). The majority of the airborne bacteria belonged to the genera Bacillus, Micrococcus, and Staphylococcus, but a total of 37 different genera were identified in the air. These results suggest that anthropogenic sources are major contributors to airborne bacteria at subway stations and that such airborne communities could harbor virulence- and survival-associated properties of potential relevance for biological detection and surveillance, as well as for public health. Our findings also contribute to the development of realistic testing and evaluation schemes for biological detection/surveillance systems by providing information that can be used to mimic real-life operational airborne environments in controlled aerosol test chambers.  相似文献   

17.
Exposure to airborne microorganisms in indoor environments may result in infectious disease or elicit an allergic or irritant response. Air handling system components contaminated by fungi have been implicated in the dispersal of spores into the indoor environment, thereby serving as a route of exposure to occupants. This study was conducted to provide quantitative data on the dispersal of spores from fungal colonies growing on three types of duct material. Galvanized metal, rigid fibrous glass ductboard, and fiberglass duct liner were soiled and contaminated with a known concentration of Penicillium chrysogenum spores. The duct materials were incubated in humidity chambers to provide a matrix of growing, sporulating fungal colonies at a contamination level of 109 colony forming units (CFU) per duct section, consistent for all materials. For each experiment a contaminated duct section was inserted into the air handling system of an experimental room, and the air handling system was operated for three 5-minute cycles with an air flow of 4.2 m3 min–1. The duct air velocity was approximately 2.8 m sec–1. The airborne concentration of culturable P. chrysogenum spores (CFU m–3), total P. chrysogenum spores (spores m–3), and total P. chrysogenum-sized particles (particles m–3) were measured in the room using Andersen single-stage impactor samplers, Burkard slide impactor samplers, and an aerodynamic particle sizer, respectively. The highest airborne concentrations (104 CFU m–3; 105 spores m–3; 104 particles m–3) were measured during the first operating cycle of the air handling system for all duct materials with decreasing airborne concentrations measured during the second and third cycles. There was no significant difference in spore dispersal from the three contaminated duct materials. These data demonstrate the potential exposure for building occupants to high concentrations of spores dispersed from fungal colonies on air handling system duct materials during normal operation of the system.  相似文献   

18.
The short-term dynamics and distribution of airborne biological and total particles have been assessed in a large university hallway by particle counting using laser particle counters and impaction air samplers. Particle numbers of four different size ranges were determined every 2 min over several hours. Bioaerosols (culturable bacteria and fungi determined as colony-forming units) were directly collected every 5 min on Petri dishes containing the appropriate growth medium. Results clearly show distinct short-term dynamics of particulate aerosols, of both biological and non-biological origin. These reproducible periodic patterns are closely related to periods when lectures are held in lecture rooms and the intermissions in between when students are present in the hallway. Peaks of airborne culturable bacteria were observed with a periodicity of 1 h. Bioaerosol concentrations follow synchronously the variation in the total number of particles. These highly reproducible temporal dynamics should be considered when monitoring indoor environments to determine air quality.  相似文献   

19.
娄彩荣  刘红玉  李玉玲  李玉凤 《生态学报》2016,36(21):6719-6729
颗粒物PM_(2.5)、PM_(10)是近年来我国大气首要污染物,威胁环境和人类健康。地表景观结构直接或间接影响PM_(2.5)、PM_(10)浓度,了解其影响过程和机理对于改善生态环境具有重要意义。系统总结了国内外关于PM_(2.5)、PM_(10)对地表景观结构响应的研究成果,指出研究中出现不确定性的可能影响因素,并对今后的发展方向进行展望。得出基本结论:(1)地表景观类型的构成及其格局显著影响大气颗粒物浓度,对PM_(2.5)、PM_(10)起到"源"和"汇"的作用。(2)地表景观结构引起局地气候变化并影响颗粒物的迁移转化,但其影响过程和机理复杂,研究结论并不明确。(3)颗粒物浓度和地表景观数据主要通过实际监测或遥感处理方法获得,但因为获取方法、监测点微观环境及遥感影像等因素影响,导致数据具有不确定性,加上时空尺度相对应的复杂性,大大限制了地表景观结构与PM_(2.5)、PM_(10)响应关系的研究进展,是未来要突破的难点。(4)PM_(2.5)、PM_(10)对地表景观结构响应的区域时空差异及过程,局地小气候变化对颗粒物浓度的影响过程和强度,主要景观类型尤其是水体、湿地景观对大气颗粒物浓度的影响过程、机理与贡献程度等是未来需要关注的方向。  相似文献   

20.
To evaluate risk via inhalation exposure of polybrominated diphenyl ethers (PBDEs) in office environment, thirty-six pairs air samples including PM2.5 (particles with aerodynamic diameter less than 2.5 μm), PM10 (particles with aerodynamic diameter less than 10 μm), total suspended particles (TSP) with matching gas phase were collected in office environment in Shanghai, China. The average concentrations of PM2.5, PM10 and TSP were 20.4, 27.2 and 50.3 μg/m3, respectively. Σ15PBDEs mean concentrations in PM2.5, PM10, TSP and gas phase were 51.8, 110.7, 148 and 59.6 pg/m3, respectively. Much more PBDEs distributed in fine fractions than coarse ones. PBDEs congener profiles found in PM2.5, PM10 and TSP (dominated by BDE-209) were different from that in gas phase (dominated by the tri- to penta-BDEs). Approximately 3.20 pg/kg/d PM2.5 bound PBDEs can be inhaled into the lung; 3.62 pg/kg/d PM10-PM2.5(particles with aerodynamic diameter of 2.5-10 μm) bound PBDEs tended to be deposited in the upper part of respiratory system, and the intake of PBDEs via gas-phase was 2.74 pg/kg/d. The exposure of PBDEs was far below the minimal risk levels (MRLs), indicating lower risk from PBDEs via inhalation in the studied office in Shanghai.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号