首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A search for fluorescent emission due to the presence of possible organic molecules in the Jovian atmosphere is described. We first consider natural Jovian fluorescent emission excited by precipitating auroral particles. Due to our lack of knowledge of the Jovian precipitation particle energies and fluxes we next consider fluorescent emission excited by a laser system aboard a Jupiter spacecraft. Laser-induced fluorescence is routinely used to monitor trace constituents and pollutants in the terrestrial atmosphere. Several spacecraft laser systems are currently under development. Our calculations indicate that laser-induced fluorescent detection is approximately two orders of magnitude more sensitive than rocket ultraviolet measurements of possible Jovian absorption features at 2600 A that have been attributed to the presence of adenine or benzene.  相似文献   

2.
A number of histochemical chromogenic substrates for alkaline phosphatase are commercially available and give reaction products with a range of colours for brightfield examination. Some of these reaction products are also fluorescent, exhibiting a wide excitation range and a broad emission peak. We report here that one of these substrates, Vector Blue III, yields a stable, strongly fluorescent reaction product with an excitation peak around 500 nm and a large Stokes shift to an emission peak at 680 nm. The reaction product can be excited using a mercury lamp with a fluorescein excitation filter or an argon ion laser at 488 nm or 568 nm, and the emission detected using a long-pass filter designed for Cy-5. Thus, a single substrate is suitable for brightfield imaging of tissue sections and high-resolution analysis of subcellular detail, using a confocal laser scanning microscope, in the same specimen.  相似文献   

3.
Dual-color fluorescence cross-correlation spectroscopy (FCCS) is a promising technique for quantifying protein-protein interactions. In this technique, two different fluorescent labels are excited and detected simultaneously within a common measurement volume. Difficulties in aligning two laser lines and emission crossover between the two fluorophores, however, make this technique complex. To overcome these limitations, we developed a fluorescent protein with a large Stokes shift. This protein, named Keima, absorbs and emits light maximally at 440 nm and 620 nm, respectively. Combining a monomeric version of Keima with cyan fluorescent protein allowed dual-color FCCS with a single 458-nm laser line and complete separation of the fluorescent protein emissions. This FCCS approach enabled sensitive detection of proteolysis by caspase-3 and the association of calmodulin with calmodulin-dependent enzymes. In addition, Keima and a spectral variant that emits maximally at 570 nm might facilitate simultaneous multicolor imaging with single-wavelength excitation.  相似文献   

4.
BACKGROUND: The aims of this study were (1) to realign cellular preparations when spots and structures are excited by different lasers of a confocal laser scanning microscope (multilaser studies); (2) to avoid the use of realigment methods by selecting fluorochromes that can be excited by only one laser (single-laser experiments). METHODS: In multilaser studies, we used propidium iodide fluorescent beads, as well as tetramethyl rhodamine isothiocyanate (TRITC), fluorescein isothiocyanate (FITC), and 4'-6 diamidino-2-phenylindole (DAPI)-stained human cancer lines. They were excited using HeNe, argon, and ultraviolet (UV) argon laser lines of a confocal laser scanning microscope. Single-laser experiments using UV excitation only were performed using europium as a model for magnetic resonance paramagnetic contrast agents. Nuclei of human cancer lines and tissue were counterstained by DAPI and cytoplasms were labeled with ELF-97 substrates. Factor analysis of medical images (FAMIS) and correlation methods were used to realign shifted images, focus images, and characterize each fluorochrome when necessary. RESULTS: In multilaser studies, superimposition of factor images corrected Z shifts and correlation methods provided X, Y correction values. In single-laser experiments, each fluorochrome was clearly distinguished in the group of fluorochromes. Estimated images in both studies showed colocalizations of structures. CONCLUSIONS: It is possible to characterize differences in the focus and alignment of fluorescent probes and to correct them. It is also possible to study colocalization of UV excitable fluorochromes (DAPI, ELF-97, europium) in cellular and tissular preparations via multilaser or single-laser experiments.  相似文献   

5.
In extracts of acid treated molybdenum cofactor containing xanthine oxidase, fluorescence is maximally developed upon a three hours incubation. Analysis by means of reversed phase HPLC revealed the presence of several fluorescent compounds, the main one being a blue fluorescent compound with an emission maximum of 465 nm when maximal excited at 395 nm at a neutral pH. Definite proof is presented that this compound is the oxidation product of the molybdenum cofactor. The remaining fluorescent products are shown to be pterin-derivatives, yielding predominantly pterin-6-carboxylic acid upon permanganate oxidation. Purified oxidation product of molybdenum cofactor however, didn's yield a fluorescent derivative at all upon treatment with permanganate.  相似文献   

6.
Detection of Forster resonance energy transfer (FRET) between fluorescent protein labeled targets is a valuable strategy for measurement of protein-protein interactions and other intracellular processes. Despite the utility of FRET, widespread application of this technique to biological problems and high-throughput screening has been limited by low-contrast measurement strategies that rely on the detection of sensitized emission or photodestruction of the sample. Here we report a FRET detection strategy based on detecting depolarized sensitized emission. In the absence of FRET, we show that fluorescence emission from a donor fluorescent protein is highly polarized. Depolarization of fluorescence emission is observed only in the presence of energy transfer. A simple detection strategy was adapted for fluorescence microscopy using both laser scanning and wide-field approaches. This approach is able to distinguish FRET between linked and unlinked Cerulean and Venus fluorescent proteins in living cells with a larger dynamic range than other approaches.  相似文献   

7.
Improvements and extended applications of time-resolved delayed luminescence imaging microscopy (TR-DLIM) in cell biology are described. The emission properties of europium ion complexed to a fluorescent chelating group capable of labeling proteins are exploited to provide high contrast images of biotin labeled ligands through detection of the delayed emission. The streptavidin-based macromolecular complex (SBMC) employs streptavidin cross-linked to thyroglobulin multiply labeled with the europium-fluorescent chelate. The fluorescent chelate is efficiently excited with 340-nm light, after which it sensitizes europium ion emission at 612 nm hundreds of microseconds later. The SBMC complex has a high quantum yield orders of magnitude higher than that of eosin, a commonly used delayed luminescent probe, and can be readily seen by the naked eye, even in specimens double-labeled with prompt fluorescent probes. Unlike triplet-state phosphorescent probes, sensitized europium ion emission is insensitive to photobleaching and quenching by molecular oxygen; these properties have been exploited to obtain delayed luminescence images of living cells in aerated medium thus complementing imaging studies using prompt fluorescent probes. Since TR-DLIM has the unique property of rejecting enormous signals that originate from scattered light, autofluorescence, and prompt fluorescence it has been possible to resolve double emission images of living amoeba cells containing an intensely stained lucifer yellow in pinocytosed vesicles and membrane surface-bound SBMC-labeled biotinylated concanavalin A. Images of fixed cells represented in terms of the time decay of the sensitized emission show the lifetime of the europium ion emission is sensitive to the environment in which it is found.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

8.
Three-photon induced fluorescence of the calcium probe Indo-1.   总被引:1,自引:0,他引:1       下载免费PDF全文
We report the calcium-dependent emission spectral properties of the calcium probe Indo-1 for three-photon excitation. We found that Indo-1 could be readily excited with the femtosecond pulses from a mode-locked Ti:sapphire laser at 885 nm. This wavelength is too long for two-photon excitation, which is expected to occur for wavelengths no longer than twice the longest single-photon absorption wavelength of 400 nm. For excitation at 885 nm the emission intensity was found to depend on the cube of the laser power, as expected for simultaneous interaction with three photons. At wavelengths below 840 nm the emission intensity depends on the square of the laser power, indicating two-photon excitation at shorter wavelengths. The intensity decays of Indo-1 were found to be dependent on Ca2+ and essentially identical for one- and three-photon excitation. The emission anisotropy of Indo-1 was found to be considerably higher for three-photon excitation than for one-photon excitation, consistent with cos6 theta photoselection, as compared with cos2 theta photoselection for one-photon excitation. The high values of the anisotropy are in agreement with those expected for a three-photon process. Calcium-dependent emission spectra were observed for Indo-1 with three-photon excitation, demonstrating that three-photon excitation of Indo-1 can be used for calcium imaging by emission intensity ratio measurements. The calcium-dependent emission spectra indicate a higher three-photon cross-section for the calcium-free form of Indo-1 than for the calcium-bound form. The possible advantages of three-photon excitation include the availability of the appropriate wavelengths with solid-state lasers, enhanced spatial resolution due to a reduced size of the excited volume, absence of light quenching, and possibly high selectivity of the three-photon excitation process.  相似文献   

9.
Analysis of dead versus live cells is shown to be possible using Calcoflour White M2R (CFW), a fluorescent brightener. Comparison of CFW with both propidium iodide (PI) and fluorescein diacetate (FDA) was performed on a FACS 440 dual laser flow cytometer on several populations of cultured rat and mouse cell lines, peripheral leukocytes, splenocytes, diatoms, and plant protoplasts. As a measure of cell viability, staining results with CFW were strongly associated with PI (correlation coefficient of 0.9886) and FDA (inverse correlation coefficient of 0.9647). With plant and algal cells, controls are necessary as CFW does stain live cells to some extent. CFW (excitation: UV, emission max: 435 nm) can be used in conjunction with two-color immunofluorescence analysis using fluorochromes excited at 488 nm with no interference.  相似文献   

10.
A microscope based time-correlated single photon counting instrument has been constructed to measure fluorescence intensity and emission anisotropy decays from fluorophores in single cells on a nanosecond time scale. The sample is excited and the emission collected using epi-illumination optics with frequency-doubled pulses from the cavity-dumped output of a synchronously pumped dye laser serving as an excitation source. Collection of decays from a single cell is possible due to the presence of an iris in the emission path that can be reduced to less than the diameter of a single cell. Using the instrument the decay of 60 nM 1,6-diphenyl-1,3,5-hexatriene was measured, demonstrating that adequate data for lifetime analysis can be recorded from fewer 10(3) molecules of the fluorophore in an illuminated volume of 23 fl. In addition, the intensity and anisotropy decays of fura-2 in single adherent cells and in suspensions of fura-2 loaded cells in suspension, although the relative amplitudes and decay constants vary somewhat from cell to cell. The results indicate that a significant but variable fraction of fura-2 is bound to relatively immobile macromolecular components in these cells.  相似文献   

11.
Energy transfer in a bioluminescent system   总被引:19,自引:0,他引:19  
Many (but not all) of the bioluminescent systems in coelenter-ates involve energy transfer from an excited product molecule of the calcium activated photoprotein to a second species, the green fluorescent protein, with emission at 508 nm from its excited state. Although all the luminescent coelen-terates studied possess photoproteins, not all of them have the green fluorescent protein. This green fluorescent molecule is localized in the luminescent cells; they can thus be easily distinguished by fluorescence microscopy. The active components occur in subcellular particles; these have been isolated in an active form by homogenization in isotonic (to sea water) salt solutions.  相似文献   

12.
Helium-neon lasers are economical and efficient light sources; their utility in flow cytometry to date has been limited by the lack of fluorescent probes that can be excited at 633 nm. Allophycocyanin (APC), a highly fluorescent phycobiliprotein, can be used as an antibody label and has spectral characteristics suitable for use with He-Ne lasers; we undertook to resolve whether a low-power (7 mW) He-Ne laser could provide sufficient excitation to permit flow cytometric detection of APC-labeled antibodies on cell surfaces. We made an APC conjugate of monoclonal antibody 4F2, which reacts with an antigen abundant on the surfaces of activated human T-lymphocytes; APC-4F2 was used to stain blood mononuclear cells that had been cultured with and without phytohemagglutinin (PHA). Cells so stained were examined in a flow cytometer with orthogonal illumination at 633 nm from a 7 mW He-Ne laser; antibody-bearing cells were detectable by fluorescence emission above 665 nm. Cells from the same cultures were stained with fluorescein-labeled 4F2 antibody and examined in a flow cytometer with argon ion laser excitation at 488 nm. Percentages of antibody-bearing cells determined from APC fluorescence and from fluorescein fluorescence were in good agreement. It thus appears that He-Ne lasers and APC-antibodies are usable for immunofluorescence measurements; the sensitivity attainable with this technique remains to be determined.  相似文献   

13.
Flow cytometers based on optical sensing utilize external light sources and fluorescent dyes to measure one or more specific components or properties of individual cells or subcellular particles in liquid suspension. To provide for independent excitation of two dyes used in double staining experiments we have constructed a high resolution flow cytometer that uses two laser beams to provide two wavelengths of excitation. These beams are separated spatially so that cells flow through them sequentially, with a time separation of about 20 musec. Since the dyes are excited sequentially their emission occurs at different times and their emission spectra may overlap without causing any difficulty in analysis. We have developed new light collection optics that permit up to four measurements to be made on each cell. This approach greatly increases the number of dye combinations that can be used in flow cytometry, thus removing a significant limitation of single illumination instruments.  相似文献   

14.
The fluorescence spectral properties of recombinant green fluorescent protein (rGFP) were examined with one- and two-photon excitations using femtosecond pulses from a Ti:sapphire laser. Intensity-dependent properties of the two-photon-induced fluorescence from rGFP excited by an 800-nm, 100-fs laser beam were reported, and the two-photon excitation cross section of rGFP was measured at 800 nm as about 160 x 10(-50) cm(4)s/photon. The possible excited-state proton transfer between two electronic states at about 400 nm in protonated (RH) species and 478 nm in deprotonated (R(-)) species in rGFP was confirmed by fluorescence and fluorescence excitation anisotropy spectra. A subelectronic state (or vibronic progression) at about 420 nm in RH species was identified, which was relatively stable and not involved in the excited state proton transfer in rGFP upon irradiation.  相似文献   

15.
We consider the effect of planar dielectric interfaces (e.g., solid/liquid) on the fluorescence emission of nearby probes. First, we derive an integral expression for the electric field radiated by an oscillating electric dipole when it is close to a dielectric interface. The electric field depends on the refractive indices of the interface, the orientation of the dipole, the distance from the dipole to the interface, and the position of observation. We numerically calculate the electric field intensity for a dipole on an interface, as a function of observation position. These results are applicable to fluorescent molecules excited by the evanescent field of a totally internally reflected laser beam and thus very close to a solid/liquid interface. Next, we derive an integral expression for the electric field radiated when a second dielectric interface is also close to the fluorescent molecule. We numerically calculate this intensity as observed through the second interface. These results are useful when the fluorescence is collected by a high-aperture microscope objective. Finally, we define and calculate a "dichroic factor," which describes the efficiency of collection, in the two-interface system, of polarized fluorescence. The limit when the first interface is removed is applicable for any high-aperture collection of polarized or unpolarized fluorescence. The limit when the second interface is removed has application in the collection of fluorescence with any aperture from molecules close to a dielectric interface. The results of this paper are required for the interpretation of order parameter measurements on fluorescent probes in supported phospholipid monolayers (Thompson, N.L., H. M. McConnell, and T. P. Burghardt, 1984, Biophys. J., 46:739-747).  相似文献   

16.
Ion permeation, triggered by ligand-receptor interaction, is associated with the primary events of membrane depolarization at the neuromuscular junction and synaptic connections. To explore the possible sites of ion permeation, the long-lived fluorescent probe pyrene (fluorescence lifetime ~400 nsec) has been inserted into the lipid phase of acetylcholine receptor-rich membrane (AcChR-M) preparations from Torpedo californica. The pyrene probe is susceptible to both fluidity and permeability changes in the lipid bilayer. These changes are detected by variations in the rate of decay of the excited singlet state of pyrene after pulsation with a 10-nsec ruby laser flash. Variations of these lifetimes in the membrane preparations alone or in the presence of quenchers show that binding of cholinergic agonists and antagonists, neurotoxins, and local anesthetics to AcChR-M produces varying effects on the properties of the pyrene probe in the lipid phase. It is concluded that binding of cholinergic ligands to the receptor does not significantly alter the fluidity or permeability of the lipids in the bilayer in contact with pyrene. On the other hand, local anesthetics do affect these properties.  相似文献   

17.
B L Roth  M Poot  S T Yue    P J Millard 《Applied microbiology》1997,63(6):2421-2431
A fluorescent nucleic acid stain that does not penetrate living cells was used to assess the integrity of the plasma membranes of bacteria. SYTOX Green nucleic acid stain is an unsymmetrical cyanine dye with three positive charges that is completely excluded from live eukaryotic and prokaryotic cells. Binding of SYTOX Green stain to nucleic acids resulted in a > 500-fold enhancement in fluorescence emission (absorption and emission maxima at 502 and 523 nm, respectively), rendering bacteria with compromised plasma membranes brightly green fluorescent. SYTOX Green stain is readily excited by the 488-nm line of the argon ion laser. The fluorescence signal from membrane-compromised bacteria labeled with SYTOX Green stain was typically > 10-fold brighter than that from intact organisms. Bacterial suspensions labeled with SYTOX Green stain emitted green fluorescence in proportion to the fraction of permeabilized cells in the population, which was quantified by microscopy, fluorometry, or flow cytometry. Flow cytometric and fluorometric approaches were used to quantify the effect of beta-lactam antibiotics on the cell membrane integrity of Escherichia coli. Detection and discrimination of live and permeabilized cells labeled with SYTOX Green stain by flow cytometry were markedly improved over those by propidium iodide-based tests. These studies showed that bacterial labeling with SYTOX Green stain is an effective alternative to conventional methods for measuring bacterial viability and antibiotic susceptibility.  相似文献   

18.
Metallic nanoparticles (NPs) are able to modify the excitation and emission rates (plasmonic enhancement) of fluorescent molecules in their close proximity. In this work, we measured the emission spectra of 20 nm Gold Nanoparticles (AuNPs) fixed on a glass surface submerged in a solution of different fluorophores using a spectral camera and 2-photon excitation. While on the glass surface, we observed the presence in the emission at least 3 components: i) second harmonic signal (SHG), ii) a broad emission from AuNPS and iii) fluorescence arising from fluorophores nearby. When on the glass surface, we found that the 3 spectral components have different relative intensities when the incident direction of linear polarization was changed indicating different physical origins for these components. Then we measured by fluctuation correlation spectroscopy (FCS) the scattering and fluorescence signal of the particles alone and in a solution of 100 nM EGFP using the spectral camera or measuring the scattering and fluorescence from the particles. We observed occasional fluorescence bursts when in the suspension we added fluorescent proteins. The spectrum of these burst was devoid of the SHG and of the broad emission in contrast to the signal collected from the gold nanoparticles on the glass surface. Instead we found that the spectrum during the burst corresponded closely to the spectrum of the fluorescent protein. An additional control was obtained by measuring the cross-correlation between the reflection from the particles and the fluorescence arising from EGFP both excited at 488 nm. We found a very weak cross-correlation between the AuNPs and the fluorescence confirming that the burst originate from a few particles with a fluorescence signal.  相似文献   

19.
A procedure for the synthesis of a ratiometric viscosity fluorescent sensor is described in this protocol. The essential requirement for the design of this sensor is the attachment of a primary fluorophore that has both a viscosity-independent fluorescence emission (coumarin dye shown in blue) and an emission from a fluorophore that exhibits viscosity-dependent fluorescent quantum yield (p-amino cinnamonitrile dye shown in red). The use of sensor 1 in viscosity measurements involves solubilization in a liquid of interest and excitation of the primary fluorophore at lambda(ex) = 360 nm. The secondary fluorophore is simultaneously excited via resonance energy transfer. The ratio of the fluorescent emission of the secondary over the primary fluorophore provides a fast and precise measurement of the viscosity of the solvent. The synthesis of compound 1 using commercially available materials can be completed within 5 d.  相似文献   

20.
Apomyoglobin was labeled with the fluorescent probe 2-p-toluidinylnaphthalene-6-sulfonic acid (TNS). Apparent phase shift and demodulation lifetimes of bound TNS were measured at various emission wavelengths. The lifetimes increased with increasing wavelength. Similar results were obtained for TNS in the viscous solvent glycerol at 10°C but not for TNS in vitrified or fluid solvent. The wavelength-dependent lifetimes suggest apomyoglobin is relaxing around the TNS molecule during its fluorescent lifetime. Importantly, the apparent phase lifetimes exceeded the apparent modulation lifetimes on the long wavelength side of the emission for TNS in apomyoglobin at 3°C and for TNS in glycerol at 10°C. This result proves the increasing lifetimes are a result of an excited state reaction during the lifetime of the excited state and are not a result of heterogeneity in the fluorescence emission. From the lifetimes on the short wavelength side of the emission the relaxation time of apomyoglobin was estimated to be 18 nsec.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号