首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
2.
AimTo investigate the predictive value of convenience of rectum dosimetry with Quantitative Analysis of Normal Tissue Effects in the Clinic (QUANTEC) dose limits, maximum rectum dose (Dmax), total rectal volume (TVrectum), rectal volume included in PTV (VrectumPTV) on Grade 2–3 acute rectal toxicity for utilization in clinical practice.BackgroundNumerous previous data have reported frequent acute proctitis after external-beam RT of prostate cancer. Predicting toxicity limited with dose information is inadequate in clinical practice due to comorbidities and medications used.Materials and MethodSixty-four non-metastatic prostate cancer patients treated with IMRT were enrolled. Patients were treated to a total dose of 70–76 Gy. Rectal dose volume histograms (DVH) of all patients were evaluated retrospectively, and a QUANTEC Score between 0 and 5 was calculated for each patient. The correlation between the rectal DVH data, QUANTEC score, TVrectum, VrectumPTV, rectum Dmax and Grade 2–3 rectal toxicity was investigated.ResultsIn the whole group grade 1, 2 and 3 acute rectal toxicities were 25%, 18.8% and 3.1%, respectively. In the DVH data, rectum doses of all patients were under RTOG dose limits. Statistically significant correlation was found between grade 2–3 rectal toxicity and TVrectum (p = 0,043); however. It was not correlated with QUANTEC score, VrectumPTV and Dmax.ConclusionOur results were not able to show any significant correlation between increasing convenience with QUANTEC limits and lower rectal toxicity. Conclusively, new dosimetric definitions are warranted to predict acute rectal toxicity more accurately in prostate cancer patients during IMRT treatment.  相似文献   

3.
PurposeTreatment plans manually generated in clinical routine may suffer from variations and inconsistencies in quality. Using such plans for validating a DVH prediction algorithm might obscure its intrinsic prediction accuracy. In this study we used a recently published large database of Pareto-optimal prostate cancer plans to assess the prediction accuracy of a commercial knowledge-based DVH prediction algorithm, RapidPlan. The database plans were consistently generated with automated planning using an independent optimizer, and can be considered as aground truth of plan quality.MethodsPrediction models were generated using training sets with 20, 30, 45, 55 and 114 Pareto-optimal plans. Model-20 and Model-30 were built using 5 groups of randomly selected training patients. For 60 independent Pareto-optimal validation plans, predicted and database DVHs were compared.ResultsFor model-114, differences between predicted and database mean doses of more than ± 10% in rectum, anus and bladder, occurred for 23.3%, 55.0%, and 6.7% of the validation plans, respectively. For rectum V65Gy and V75Gy, differences outside the ±10% range were observed in 21.7% and 70.0% of validation plans, respectively. For 61.7% of validation plans, inaccuracies in predicted rectum DVHs resulted in a deviation in predicted NTCP for rectal bleeding outside ±10%. With smaller training sets the DVH prediction performance deteriorated, showing dependence on the selected training patients.ConclusionEven when analysed with Pareto-optimal plans with highly consistent quality, clinically relevant deviations in DVH predictions were observed. Such deviations could potentially result in suboptimal plans for new patients. Further research on DVH prediction models is warranted.  相似文献   

4.
5.
PurposeTo test the performances of a volumetric arc technique named ViTAT (Virtual Tangential-fields Arc Therapy) mimicking tangential field irradiation for whole breast radiotherapy.MethodsViTAT plans consisted in 4 arcs whose starting/ending position were established based on gantry angle distribution of clinical plans for right and left-breast. The arcs were completely blocked excluding the first and last 20°. Different virtual bolus densities and thicknesses were preliminarily evaluated to obtain the best plan performances. For 40 patients with tumor laterality equally divided between right and left sides, ViTAT plans were optimized considering the clinical DVHs for OARs (resulting from tangential field manual planning) to constrain them: ViTAT plans were compared with the clinical tangential-fields in terms of DVH parameters for both PTV and OARs.ResultsDistal angle values were suggested in the ranges [220°,240°] for the right-breast and [115°,135°] for the left-breast cases; medial angles were [60°,40°] for the right side and [295°,315°] for the left side, limiting the risk of collision. The optimal virtual bolus had −500 HU density and 1.5 cm thickness. ViTAT plans generated dose distributions very similar to the tangential-field plans, with significantly improved PTV homogeneity. The mean doses of ipsilateral OARs were comparable between the two techniques with minor increase of the low-dose spread in the range 2–15 Gy (few % volume); contralateral OARs were slightly better spared with ViTAT.ConclusionViTAT dose distributions were similar to tangential-fields. ViTAT should allow automatic plan optimization by developing knowledge-based DVH prediction models of patients treated with tangential-fields.  相似文献   

6.
7.
PurposeThis study aims to use GATE/Geant4 simulation code to evaluate the performance of dose calculations with Anisotropic Analytical Algorithm (AAA) in the context of lung SBRT for complex treatments considering images of patients.MethodsFour cases of non-small cell lung cancer treated with SBRT were selected for this study. Irradiation plans were created with AAA and recalculated end to end using Monte Carlo (MC) method maintaining field configurations identical to the original plans. Each treatment plan was evaluated in terms of PTV and organs at risk (OARs) using dose-volume histograms (DVH). Dosimetric parameters obtained from DVHs were used to compare AAA and MC.ResultsThe comparison between the AAA and MC DVH using gamma analysis with the passing criteria of 3%/3% showed an average passing rate of more than 90% for the PTV structure and 97% for the OARs. Tightening the criteria to 2%/2% showed a reduction in the average passing rate of the PTV to 86%. The agreement between the AAA and MC dose calculations for PTV dosimetric parameters (V100; V90; Homogeneity index; maximum, minimum and mean dose; CIPaddick and D2cm) was within 18.4%. For OARs, the biggest differences were observed in the spinal cord and the great vessels.ConclusionsIn general, we did not find significant differences between AAA and MC. The results indicate that AAA could be used in complex SBRT cases that involve a larger number of small treatment fields in the presence of tissue heterogeneities.  相似文献   

8.

Aim

To evaluate the association between dose–volume histogram (DVH) values in organs at risk (OAR) and patient-reported HRQoL outcomes.

Background

Data on the association between DVHs and health-related quality of life (HRQoL) in prostate cancer (PCa) patients are limited.

Materials and methods

Five-year follow-up study of 154 patients with organ-confined (stage T1/T2) PCa treated with EBRT between January 2003 and November 2005. HRQoL was evaluated with the Expanded Prostate Cancer Index (EPIC). DVH for OARs (penile bulb, rectum and bladder) were created for all patients for whom data were available (119/154; 77%). The functional data analysis (FDA) statistical method was used. HRQoL data was collected prospectively and data analysis was performed retrospectively.

Results

Worsening of urinary incontinence and obstructive symptoms correlated with higher DVH dose distributions at 24 months. Increased rectal bleeding at months 24 and 60 correlated with higher DVH dose distributions in the 40–70?Gy range. Patients with deterioration in rectal incontinence presented a higher DVH distribution range than patients without rectal incontinence. Penile bulb DVH values and erectile dysfunction were not significantly associated.

Conclusions

DVH parameters and post-radiotherapy HRQoL appear to be closely correlated, underscoring the importance of assessing DVH values prior to initiating EBRT to determine the risk of developing HRQoL related adverse effects. Advanced treatment modalities may be appropriate in high risk cases to minimize treatment-related toxicity and to improve treatment outcomes and HRQoL. Future studies are needed to better elucidate the association between pre-treatment DVH parameters in organs at risk and subsequent HRQoL.  相似文献   

9.
PurposeThis study aims to investigate the feasibility of using convolutional neural networks to predict an accurate and high resolution dose distribution from an approximated and low resolution input dose.MethodsSixty-six patients were treated for prostate cancer with VMAT. We created the treatment plans using the Acuros XB algorithm with 2 mm grid size, followed by the dose calculated using the anisotropic analytical algorithm with 5 mm grid with the same plan parameters. U-net model was used to predict 2 mm grid dose from 5 mm grid dose. We investigated the two models differing for the training data used as input, one used just the low resolution dose (D model) and the other combined the low resolution dose with CT data (DC model). Dice similarity coefficient (DSC) was calculated to ascertain how well the shape of the dose-volume is matched. We conducted gamma analysis for the following: DVH from the two models and the reference DVH for all prostate structures.ResultsThe DSC values in the DC model were significantly higher than those in the D model (p < 0.01). For the CTV, PTV, and bladder, the gamma passing rates in the DC model were significantly higher than those in the D model (p < 0.002–0.02). The mean doses in the CTV and PTV for the DC model were significantly better matched to those in the reference dose (p < 0.0001).ConclusionsThe proposed U-net model with dose and CT image used as input predicted more accurate dose.  相似文献   

10.
In this study, we verified volumetric modulated arc therapy (VMAT) plans in an Elekta Synergy system with an integrated Agility 160-leaf multileaf collimator (MLC) by comparing them with Monte Carlo (MC)-calculated dose distributions using the AAPM TG-119 structure sets. The head configuration of the linear accelerator with the integrated MLC was simulated with the EGSnrc/BEAMnrc code. Firstly, the dosimetric properties of the MLC were evaluated with the MC technique and film measurements. Next, VMAT plans were created with the Pinnacle3 treatment planning system (TPS) for four regions in the AAPM TG-119 structures. They were then verified by comparing them with MC-calculated dose distributions using dose volume histograms (DVHs) and three-dimensional (3D) gamma analysis. The MC simulations for the Agility MLC dosimetric properties were in acceptable agreement with measurements. TPS-VMAT plans using TG-119 structure sets agreed with MC dose distributions within 2% in the comparison of D95 in planning target volumes (PTVs) evaluated from DVHs. In contrast, higher dose regions such as D20, D10, and D5 in PTVs for TPS tended to be smaller than MC values. This tendency was particularly noticeable for mock head and neck with complicated structures. In 3D gamma analysis, the passing rates with 3%/3mm criteria in PTVs were ≥99%, except for mock head and neck (89.5%). All passing rates for organs at risk (OARs) were in acceptable agreement of >96%. It is useful to verify dose distributions of PTVs and OARs in TPS-VMAT plans by using MC dose calculations and 3D gamma analysis.  相似文献   

11.
AimThe aim of this study is to analyse the dosimetry to the pelvic lymph nodes and its correlation to point B using CT based high dose rate brachytherapy of carcinoma cervix.BackgroundConventionally, dose to pelvic lymph nodes from intracavitary brachytherapy was reported by point B and by the reference points of the lymphatic trapezoid.Materials and methods30 consecutive CT based high dose rate applications were reviewed between February and March 2016. The high risk clinical target volume and the organs at risk and the pelvic nodal groups were contoured. DVH parameters for the right and left obturator nodal group, right and left external iliac nodal group and right and left internal iliac nodal group were recorded. Right and left point B doses were also recorded.ResultsOn analysis of the combined dose, it was found that all the DVH parameters were significantly different from point B, except the D100 obturator and D2cc internal iliac lymph node. There was a significant correlation between all DVH parameters and point B, except D2cc, D1cc and D0.1cc of external iliac. The obturator group received the highest dose contribution from brachytherapy. The mean D90 dose received per fraction for the obturator, external iliac and internal iliac nodes was 2.7 Gy, 1.17 Gy and 1.41 Gy, respectively.ConclusionsThere is a significant dose contribution to the pelvic lymph nodal groups during intracavitary brachytherapy. There is a low degree of correlation between point B dose and dosimetric parameters of the individual nodal groups. Hence, it is important to analyse the dose delivered to individual nodal groups during intracavitary brachytherapy, at least in patients with enlarged lymph nodes to calculate the cumulative dose delivered.  相似文献   

12.
13.
PurposeTo derive Normal Tissue Complication Probability (NTCP) models for severe patterns of early radiological radiation-induced lung injury (RRLI) in patients treated with radiotherapy (RT) for lung tumors. Second, derive threshold doses and optimal doses for prediction of RRLI to be used in differential diagnosis of tumor recurrence from RRLI during follow-up.Methods and materialsLyman-EUD (LEUD), Logit-EUD (LogEUD), relative seriality (RS) and critical volume (CV) NTCP models, with DVH corrected for fraction size, were used to model the presence of severe early RRLI in follow-up CTs. The models parameters, including α/β, were determined by fitting data from forty-five patients treated with IMRT for lung cancer. Models were assessed using Akaike information criterion (AIC) and area under receiver operating characteristic curve (AUC). Threshold doses for risk of RRLI and doses corresponding to the optimal point of the receiver operating characteristic (ROC) curve were determined.ResultsThe α/βs obtained with different models were 2.7–3.2 Gy. The thresholds and optimal doses curves were EUDs of 3.2–7.8 Gy and 15.2–18.1 Gy with LEUD, LogEUD and RS models, and μd of 0.013 and 0.071 with the CV model. NTCP models had AUCs significantly higher than 0.5. Occurrence and severity of RRLI were correlated with patients’ values of EUD and μd.ConclusionsThe models and dose levels derived can be used in differential diagnosis of tumor recurrence from RRLI in patients treated with RT. Cross validation is needed to prove prediction performance of the model outside the dataset from which it was derived.  相似文献   

14.
AimTo present a proposed gastric cancer intensity-modulated radiotherapy (IMRT) treatment planning protocol for an institution that have not introduced volumetric modulated arc therapy in clinical practice. A secondary aim was to determine the impact of 2DkV set-up corrections on target coverage and organ at risk (OAR).Methods and MaterialsTwenty consecutive patients were treated with a specially-designed non-coplanar 7-field IMRT technique. The isocenter-shift method was used to estimate the impact of 2DkV-based set-up corrections on the original base plan (BP) coverage. An alternative plan was simulated (SP) by taking into account isocenter shifts. The SP and BP were compared using dose-volume histogram (DVH) plots calculated for the internal target volume (ITV) and OARs.ResultsBoth plans delivered a similar mean dose to the ITV (100.32 vs. 100.40%), with no significant differences between the plans in internal target coverage (5.37 vs. 4.96%). Similarly, no significant differences were observed between the maximal dose to the spinal cord (67.70 and 67.09%, respectively) and volume received 50% of the prescribed dose of: the liver (62.11 vs. 59.84%), the right (17.62 vs. 18.58%) and left kidney (29.40 vs. 30.48%). Set-up margins (SM) were computed as 7.80 mm, 10.17 mm and 6.71 mm in the left-right, cranio-caudal and anterior-posterior directions, respectively.ConclusionPresented IMRT protocol (OAR dose constraints with selected SM verified by 2DkV verification) for stomach treatment provided optimal dose distribution for the target and the critical organs. Comparison of DVH for the base and the modified plan (which considered set-up uncertainties) showed no significant differences.  相似文献   

15.
BackgroundTargeted radionuclide therapy is a rapidly growing modality. A few commercial treatment planning systems are entering the market. However, some in-house systems are currently developed for a more flexible and customized dosimetry calculation at voxel-level. For this purpose, we developed a novel software, VoxelMed, and performed a comparison with the software STRATOS.MethodsThe validation of both of them was undertaken using radioactive phantoms with different volume inserts. A cohort of 10 patients was also studied after a therapeutic administration of 177Lu-labelled radiopeptides. The activity, number of disintegrations, absorbed dose and dose-volume histogram (DVH) were calculated for the phantoms and the kidneys in patients, which were the main critical organs at risk in this study.ResultsIn phantoms the absorbed doses computed with VoxelMed and STRATOS agree within 5%. In patients at the voxel-level the absorbed dose to kidneys (VoxelMed: mean 0.66 Gy/GBq) showed a limited difference of 5%, but with a remarkable range (−40%, +60%) between the two software packages. Voxel-dosimetry allows to estimate the dose non-homogeneities in volumes, which may be evaluated through DVHs.ConclusionThis study demonstrates that a fully 3D voxel-dosimetry with multiple SPECT images is feasible by using home-made or commercial software package and absorbed dose results obtained are similar. The main difference between the studied tools was observed in the activity integration method (effective vs physical half-time to time activity curve tail). We believe that an effective half-time integration method produces a more accurate approximation of clinical uptake and resultant dosimetry.  相似文献   

16.
Aims and objectivesTo compare dosimetrically the manual optimisation with IPSA using dose volume histograms (DVH) among patients treated for carcinoma of cervix with intracavitary brachytherapy.BackgroundWith the advent of advanced imaging modalities, there has been a shift from conventional X-ray based planning to three-dimensional planning. Manual optimisation is widely used across various institutions but it is time consuming and operator dependant. Inverse planning simulated annealing (IPSA) is now available in various brachytherapy planning systems. But there is a paucity of studies comparing manual optimisation and IPSA in treatment of carcinoma cervix with intracavitary brachytherapy and hence this study.Materials and methodsFifteen consecutive patients treated between December 2013 and March 2014 with intracavitary brachytherapy for carcinoma of cervix were selected for this study. All patients were initially treated with external beam radiotherapy followed by intracavitary brachytherapy. The DVH was evaluated and compared between manually optimised plans and IPSA in the same set of patients.ResultsThere was a significant improvement in the HRCTV coverage, mean V100 of 87.75% and 82.37% (p = 0.001) and conformity index 0.67 and 0.6 (p = 0.007) for plans generated using IPSA and manual optimisation, respectively. Homogeneity index and dose to the OARs remained similar between the two groups.ConclusionThe use of inverse planning in intracavitary brachytherapy of cervix has shown a significant improvement in the target volume coverage when compared with manual planning.  相似文献   

17.
18.
The double-strand break (dsb) is one of the most critical lesions leading to a variety of radiobiological effects. In this paper, we reconsider the previously constructed and generally accepted mathematical models for dsb generation, and give a concrete mathematical basis for the generation of dsbs and the calculation of the number of induced dsbs, under the assumption of randomness in the break location in DNA and in the number of breaks. Using these models based on the Poisson distribution and the binomial distribution, we calculate the dose dependence of dsb generation. We deduced from our models that the dose dependence of the number of dsbs is described approximately as a quadratic form in both distribution models where dsb generation is accounted for by two ssbs. Previously reported experimental data on the dsb generation in phage DNA was found to be in good agreement with our models. Though the widely used model, the linear quadratic (LQ) model or the molecular theory of dsb formation based on the Poisson distribution, also gives the quadratic term, in spite of rough estimates or some mathematical incompleteness, a marked feature of our formulation is the absence of a parameter like the $\beta $ in the quadratic term that requires experimental data to determine. Thus in this study we provide mathematical validity to the generally accepted models of the number of dsb.  相似文献   

19.
20.
PurposeImage guided adaptive radiotherapy (IGART) strategies can be used to include the temporal aspects of radiotherapy treatment. A dosimetric evaluation of on- and off-line adaptive strategies are done in this study.MethodsA library of equivalent uniform dose (EUD)-based Intensity Modulated Radiotherapy Treatment plans with incrementally increasing clinical target volume (CTV)-to-planning target volume (PTV) margins were developed for 10 patients. Utilizing daily computed tomography (CT) images an on-line strategy using a margin-of-the-day (MOD) concept that selects the best plan from the library was employed. This was compared to an off-line strategy with full analysis of accumulated dose between fractions where dosimetric deviations from the treatment intent triggered plan adaptation. A fixed margin treatment approach was used as benchmark.ResultsUsing fixed margins of <15 mm lead to under-dosages of more than 5 Gy in total delivered dose. The average CTV EUD for the off-line and on-line strategy was 50.0 ± 5.0 Gy and 50.4 ± 2.0 Gy respectively and OAR doses were comparable.ConclusionA fixed margin treatment approach yields a significant probability of CTV under-dosage. Using EUD dose metrics CTV coverage can be restored in both the off-line and on-line adaptive strategies at acceptable OAR dose levels. Considering the workload and time on the treatment machine, the off-line strategy proves to be sufficient and more practical.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏