1.
The present study aimed to compare two commercially available actigraphs, with a concurrent polysomnographic (PSG) recording. Twelve healthy volunteers (six women; age range 19-28 yrs) simultaneously wore the Basic Mini-Motionlogger® and Actiwatch® for seven overnight polysomnographic recordings. Comparisons of the following sleep measures were focused on: sleep onset latency (SOL), total sleep time, wake after sleep onset, and sleep efficiency. Both devices underestimated SOL in comparison to PSG, but they had similar performance compared to PSG for the other sleep measures. A limit of the study is that the results can be only generalized to healthy young subjects.  相似文献   

2.
The last 20 yrs have seen a marked increase in studies utilizing actigraphy in free-living environments. The aim of the present study is to directly compare two commercially available actigraph devices with concurrent polysomnography (PSG) during a daytime nap in healthy young adults. Thirty healthy young adults, ages 18–31 (mean 20.77 yrs, SD 3.14 yrs) simultaneously wore AW-64 and GT3X+ devices during a polysomnographically recorded nap. Mann-Whitney U (M-U) test, intraclass correlation coefficients, and Bland-Altman statistic were used to compare total sleep time (TST), sleep onset latency (SOL), wake after sleep onset (WASO), and sleep efficiency (SE) between the two actigraphs and PSG. Epoch-by-epoch (EBE) agreement was calculated to determine accuracy, sensitivity, specificity, predictive values for sleep (PVS) and wake (PVW), and kappa and prevalence- and bias-adjusted kappa (PABAK) coefficients. All frequency settings provided by the devices were examined. For both actigraphs, EBE analysis found accuracy, sensitivity, specificity, PVS, and PVW comparable to previous reports of other similar devices. Kappa and PABAK coefficients showed moderate to high agreement with PSG depending on device settings. The GT3X+ overestimated TST and SE, and underestimated SOL and WASO, whereas no significant difference was found between AW-64 and PSG. However, GT3X+ showed overall better EBE agreements to PSG than AW-64. We conclude that both actigraphs are valid and reliable devices for detecting sleep/wake diurnal patterns. The choice between devices should be based on several parameters as reliability, cost of the device, scoring algorithm, target population, experimental condition, and aims of the study (e.g., sleep and/or physical activity). (Author correspondence: smednick@ucr.edu)  相似文献   

3.
Middle-aged and elderly populations exhibit gender differences in polysomnographic (PSG) sleep; however, whether young men and women also show such differences remains unclear. Thirty-one young healthy sleepers (16 men and 15 women, aged 18 to 30 yr, mean+/-SD, 20.5+/-2.4 yr) completed 3 consecutive overnight sessions in a sleep laboratory, after maintaining a stable sleep-wake cycle for 1 wk before study entry. Standard PSG sleep and self-rated sleepiness data were collected each night. Across nights, women showed better sleep quality than men: they fell asleep faster (shorter sleep onset latency) and had better sleep efficiency, with more time asleep and less time awake (all differences showed large effect sizes, d=0.98 to 1.12). By contrast, men were sleepier than women across nights. Both men and women demonstrated poorer overall sleep quality on the first night compared with the subsequent 2 nights of study. We conclude young adult healthy sleepers show robust gender differences in PSG sleep, like older populations, with better sleep quality in women than in men. These results highlight the importance of gender in sleep and circadian rhythm research studies employing young subjects and have broader implications for women's health issues relating to these topics.  相似文献   

4.
Middle‐aged and elderly populations exhibit gender differences in polysomnographic (PSG) sleep; however, whether young men and women also show such differences remains unclear. Thirty‐one young healthy sleepers (16 men and 15 women, aged 18 to 30 yr, mean±SD, 20.5±2.4 yr) completed 3 consecutive overnight sessions in a sleep laboratory, after maintaining a stable sleep‐wake cycle for 1 wk before study entry. Standard PSG sleep and self‐rated sleepiness data were collected each night. Across nights, women showed better sleep quality than men: they fell asleep faster (shorter sleep onset latency) and had better sleep efficiency, with more time asleep and less time awake (all differences showed large effect sizes, d=0.98 to 1.12). By contrast, men were sleepier than women across nights. Both men and women demonstrated poorer overall sleep quality on the first night compared with the subsequent 2 nights of study. We conclude young adult healthy sleepers show robust gender differences in PSG sleep, like older populations, with better sleep quality in women than in men. These results highlight the importance of gender in sleep and circadian rhythm research studies employing young subjects and have broader implications for women's health issues relating to these topics.  相似文献   

5.
We evaluated the performance of a consumer multi-sensory wristband (Fitbit Charge 2?), against polysomnography (PSG) in measuring sleep/wake state and sleep stage composition in healthy adults.

In-lab PSG and Fitbit Charge 2? data were obtained from a single overnight recording at the SRI Human Sleep Research Laboratory in 44 adults (19—61 years; 26 women; 25 Caucasian). Participants were screened to be free from mental and medical conditions. Presence of sleep disorders was evaluated with clinical PSG. PSG findings indicated periodic limb movement of sleep (PLMS, > 15/h) in nine participants, who were analyzed separately from the main group (n = 35). PSG and Fitbit Charge 2? sleep data were compared using paired t-tests, Bland–Altman plots, and epoch-by-epoch (EBE) analysis.

In the main group, Fitbit Charge 2? showed 0.96 sensitivity (accuracy to detect sleep), 0.61 specificity (accuracy to detect wake), 0.81 accuracy in detecting N1+N2 sleep (“light sleep”), 0.49 accuracy in detecting N3 sleep (“deep sleep”), and 0.74 accuracy in detecting rapid-eye-movement (REM) sleep. Fitbit Charge 2? significantly (p < 0.05) overestimated PSG TST by 9 min, N1+N2 sleep by 34 min, and underestimated PSG SOL by 4 min and N3 sleep by 24 min. PSG and Fitbit Charge 2? outcomes did not differ for WASO and time spent in REM sleep. No more than two participants fell outside the Bland–Altman agreement limits for all sleep measures. Fitbit Charge 2? correctly identified 82% of PSG-defined non-REM–REM sleep cycles across the night. Similar outcomes were found for the PLMS group.

Fitbit Charge 2? shows promise in detecting sleep-wake states and sleep stage composition relative to gold standard PSG, particularly in the estimation of REM sleep, but with limitations in N3 detection. Fitbit Charge 2? accuracy and reliability need to be further investigated in different settings (at-home, multiple nights) and in different populations in which sleep composition is known to vary (adolescents, elderly, patients with sleep disorders).  相似文献   

6.
ABSTRACT

We compared performance in deriving sleep variables by both Fitbit Charge 2?, which couples body movement (accelerometry) and heart rate variability (HRV) in combination with its proprietary interpretative algorithm (IA), and standard actigraphy (Motionlogger® Micro Watch Actigraph: MMWA), which relies solely on accelerometry in combination with its best performing ‘Sadeh’ IA, to electroencephalography (EEG: Zmachine® Insight+ and its proprietary IA) used as reference. We conducted home sleep studies on 35 healthy adults, 33 of whom provided complete datasets of the three simultaneously assessed technologies. Relative to the Zmachine EEG method, Fitbit showed an overall Kappa agreement of 54% in distinguishing wake/sleep epochs and sensitivity of 95% and specificity of 57% in detecting sleep epochs. Fitbit, relative to EEG, underestimated sleep onset latency (SOL) by ~11 min and overestimated sleep efficiency (SE) by ~4%. There was no statistically significant difference between Fitbit and EEG methods in measuring wake after sleep onset (WASO) and total sleep time (TST). Fitbit showed substantial agreement with EEG in detecting rapid eye movement and deep sleep, but only moderate agreement in detecting light sleep. The MMWA method showed 51% overall Kappa agreement with the EEG one in detecting wake/sleep epochs, with sensitivity of 94% and specificity of 53% in detecting sleep epochs. MMWA, relative to EEG, underestimated SOL by ~10 min. There was no significant difference between Fitbit and MMWA methods in amount of bias in estimating SOL, WASO, TST, and SE; however, the minimum detectable change (MDC) per sleep variable with Fitbit was better (smaller) than with MMWA, respectively, by ~10 min, ~16 min, ~22 min, and ~8%. Overall, performance of Fitbit accelerometry and HRV technology in conjunction with its proprietary IA to detect sleep vs. wake episodes is slightly better than wrist actigraphy that relies solely on accelerometry and best performing Sadeh IA. Moreover, the smaller MDC of Fitbit technology in deriving sleep parameters in comparison to wrist actigraphy makes it a suitable option for assessing changes in sleep quality over time, longitudinally, and/or in response to interventions.  相似文献   

7.
Our aim was to compare the circadian phase characteristics of healthy adolescent and young adult males in a naturalistic summertime condition. A total of 19 adolescents (mean age 15.7 years) and 18 young adults (mean age 24.5 years) with no sleep problems took part in this study. Two-night polysomnographic (PSG) sleep recordings and 24h secretion patterns of urinary 6-sulfatoxymelatonin were monitored in all 37 subjects. Sleep-wake patterns were initially assessed at home using a standard sleep diary. Circadian assessment included the measure of dim light melatonin offset (DLMOff) and the morningness-eveningness (M/E) questionnaire. As expected, compared to young adults, adolescents habitually spent more nocturnal time in bed and spent more time (and percentage) in delta sleep. No difference was found between adolescents and young adults on multiple sleep latency test (MSLT) sleep onset latencies, M/E, melatonin secretion measures (24h total, nighttime, daytime, and night ratio), and DLMOff. For the subjects as a whole, correlational analyses revealed a significant association between the DLMOff and M/E and between both these phase markers and habitual bedtimes, habitual rising times, and melatonin secretion measures (daytime levels and the night ratio). No association was found between phase markers and daytime sleepiness or sleep consolidation parameters such as sleep efficiency or number of microarousals. These results together indicate that adolescents and young adults investigated during summertime showed similar circadian phase characteristics, and that, in these age groups, an evening phase preference is associated with a delayed melatonin secretion pattern and delayed habitual sleep patterns without a decrease in sleep consolidation or vigilance. (Chronobiology International, 17(4), 489–501, 2000)  相似文献   

8.
Although portable instruments have been used in the assessment of sleep disturbance for patients with low back pain (LBP), the accuracy of the instruments in detecting sleep/wake episodes for this population is unknown. This study investigated the criterion validity of two portable instruments (Armband and Actiwatch) for assessing sleep disturbance in patients with LBP. 50 patients with LBP performed simultaneous overnight sleep recordings in a university sleep laboratory. All 50 participants were assessed by Polysomnography (PSG) and the Armband and a subgroup of 33 participants wore an Actiwatch. Criterion validity was determined by calculating epoch-by-epoch agreement, sensitivity, specificity and prevalence and bias- adjusted kappa (PABAK) for sleep versus wake between each instrument and PSG. The relationship between PSG and the two instruments was assessed using intraclass correlation coefficients (ICC 2, 1). The study participants showed symptoms of sub-threshold insomnia (mean ISI = 13.2, 95% CI = 6.36) and poor sleep quality (mean PSQI = 9.20, 95% CI = 4.27). Observed agreement with PSG was 85% and 88% for the Armband and Actiwatch. Sensitivity was 0.90 for both instruments and specificity was 0.54 and 0.67 and PABAK of 0.69 and 0.77 for the Armband and Actiwatch respectively. The ICC (95%CI) was 0.76 (0.61 to 0.86) and 0.80 (0.46 to 0.92) for total sleep time, 0.52 (0.29 to 0.70) and 0.55 (0.14 to 0.77) for sleep efficiency, 0.64 (0.45 to 0.78) and 0.52 (0.23 to 0.73) for wake after sleep onset and 0.13 (−0.15 to 0.39) and 0.33 (−0.05 to 0.63) for sleep onset latency, for the Armband and Actiwatch, respectively. The findings showed that both instruments have varied criterion validity across the sleep parameters from excellent validity for measures of total sleep time, good validity for measures of sleep efficiency and wake after onset to poor validity for sleep onset latency.  相似文献   

9.

Sleep related bruxism (SB) is the grinding of teeth during sleep and may also be associated with various sleep disorders. However, little is known about sleep structures and disturbances of SB. This study aims to further understand sleep architectures using overnight polysomnography (PSG) in patients with SB. We analyze sleep parameters and architectures in 33 healthy subjects and 25 patients with SB. PSG and sleep questionnaires measured sleep variables including proportions of rapid eye movement (REM) sleep, non-REM sleep (N1, N2 and N3), latency to sleep onset, sleep efficiency, wake after sleep onset (WASO), apnea hypopnea index (AHI), respiratory disturbance index (RDI), and periodic limb movement index (PLMI) during sleep for both groups. Sleep efficiency and the proportion of N3 in the SB group were significantly lower than in the control group (P < 0.05). In addition latency to onset of sleep and WASO were markedly increased in the SB group (P < 0.05). AHI, RDI, and PLMI showed no differences between the groups. Epworth Sleepiness Scale was significantly higher in the SB group than in the control group (P < 0.05). In contrast to previous studies, we conclude that patients with SB are not good sleepers based on PSG study. Further studies are required to assess the relationship between sleep quality and the severity of SB.

  相似文献   

10.
Our aim was to compare the circadian phase characteristics of healthy adolescent and young adult males in a naturalistic summertime condition. A total of 19 adolescents (mean age 15.7 years) and 18 young adults (mean age 24.5 years) with no sleep problems took part in this study. Two-night polysomnographic (PSG) sleep recordings and 24h secretion patterns of urinary 6-sulfatoxymelatonin were monitored in all 37 subjects. Sleep-wake patterns were initially assessed at home using a standard sleep diary. Circadian assessment included the measure of dim light melatonin offset (DLMOff) and the morningness-eveningness (M/E) questionnaire. As expected, compared to young adults, adolescents habitually spent more nocturnal time in bed and spent more time (and percentage) in delta sleep. No difference was found between adolescents and young adults on multiple sleep latency test (MSLT) sleep onset latencies, M/E, melatonin secretion measures (24h total, nighttime, daytime, and night ratio), and DLMOff. For the subjects as a whole, correlational analyses revealed a significant association between the DLMOff and M/E and between both these phase markers and habitual bedtimes, habitual rising times, and melatonin secretion measures (daytime levels and the night ratio). No association was found between phase markers and daytime sleepiness or sleep consolidation parameters such as sleep efficiency or number of microarousals. These results together indicate that adolescents and young adults investigated during summertime showed similar circadian phase characteristics, and that, in these age groups, an evening phase preference is associated with a delayed melatonin secretion pattern and delayed habitual sleep patterns without a decrease in sleep consolidation or vigilance. (Chronobiology International, 17(4), 489-501, 2000)  相似文献   

11.
The literature widely recognizes that shift workers have more health complaints than the general population. The objective of this study was to describe the prevalence of sleep complaints and verify the polysomnographic (PSG) variables of shift workers in two Brazilian nuclear power plants. We carried out a subjective evaluation with a sleep questionnaire. Based on these results, the interviewees that reported sleep‐related complaints were referred for polysomnographic evaluation. Of the 327 volunteers initially evaluated by the sleep questionnaire, 113 (35%) reported sleep complaints; they were significantly older, had higher body mass index (BMI), and worked more years on shifts than those without sleep complaints. Of these 113, 90 met criteria for various sleep disorders: 30 (9%) showed obstructive sleep apnea (OSA), 18 (5.5%) showed limb movement, and 42 (13%) evidenced both sleep problems and had a significantly higher proportion of sleep stage 1 and arousals compared with the 23 shift workers that had no indices of sleep problems. The present study found that 90 (27.5%) of the evaluated participants met the PSG criteria of some type of clinical sleep disorder. This high proportion should be investigated for associations with other aspects of work, such as working hours, working schedule, years performing shift work, and access to health services. Due to the strong association between sleep disorders and the incidence of fatigue and sleepiness, the evaluation of the sleep patterns and complaints of shift workers is essential and should be considered to be one of the basic strategies of industry to prevent accidents.  相似文献   

12.
The literature widely recognizes that shift workers have more health complaints than the general population. The objective of this study was to describe the prevalence of sleep complaints and verify the polysomnographic (PSG) variables of shift workers in two Brazilian nuclear power plants. We carried out a subjective evaluation with a sleep questionnaire. Based on these results, the interviewees that reported sleep-related complaints were referred for polysomnographic evaluation. Of the 327 volunteers initially evaluated by the sleep questionnaire, 113 (35%) reported sleep complaints; they were significantly older, had higher body mass index (BMI), and worked more years on shifts than those without sleep complaints. Of these 113, 90 met criteria for various sleep disorders: 30 (9%) showed obstructive sleep apnea (OSA), 18 (5.5%) showed limb movement, and 42 (13%) evidenced both sleep problems and had a significantly higher proportion of sleep stage 1 and arousals compared with the 23 shift workers that had no indices of sleep problems. The present study found that 90 (27.5%) of the evaluated participants met the PSG criteria of some type of clinical sleep disorder. This high proportion should be investigated for associations with other aspects of work, such as working hours, working schedule, years performing shift work, and access to health services. Due to the strong association between sleep disorders and the incidence of fatigue and sleepiness, the evaluation of the sleep patterns and complaints of shift workers is essential and should be considered to be one of the basic strategies of industry to prevent accidents.  相似文献   

13.

We examined the effects of low-dose oral risperidone (RIS) on nocturnal sleep in healthy participants. This study was performed in a placebo-controlled manner in 10 healthy male volunteers (mean age, 23.6 years), with administration of 0.5 mg of RIS oral solution or a placebo in the morning or evening for 2 consecutive days. Each night, polysomnography (PSG) was performed, and PSG data during non-rapid-eye movement (REM) sleep were processed by power spectral analysis. An evening administration of 0.5 mg RIS significantly increased total sleep time, sleep efficiency and sleep stage 3, and significantly decreased total waking time and waking after sleep onset (P < 0.05). A morning administration of 0.5 mg RIS significantly increased sleep stage 3 (P < 0.05). According to power spectral analysis, the evening administration of RIS significantly increased the theta power (P < 0.05) and decreased the beta power (P < 0.05) during non-REM sleep. The administration of 0.5 mg oral RIS increases sleep stage 3 and increases total sleep time following evening administration.

  相似文献   

14.
Electroencephalographic (EEG) arousals are seen in EEG recordings as an awakening response of the human brain. Sleep apnea is a serious sleep disorder. Severe sleep apnea brings about EEG arousals and sleep for patients with sleep apnea syndrome (SAS) is thus frequently interrupted. The number of respiratory-related arousals during the whole night on PSG recordings is directly related to the quality of sleep. Detecting EEG arousals in the PSG record is thus a significant task for clinical diagnosis in sleep medicine. In this paper, a method for automatic detection of EEG arousals in SAS patients was proposed. To effectively detect respiratory-related arousals, threshold values were determined according to pathological events as sleep apnea and electromyogram (EMG). If resumption of ventilation (end of the apnea interval) was detected, much lower thresholds were adopted for detecting EEG arousals, including relatively doubtful arousals. Conversely, threshold was maintained high when pathological events were undetected. The proposed method was applied to polysomnographic (PSG) records of eight patients with SAS and accuracy of EEG arousal detection was verified by comparative visual inspection. Effectiveness of the proposed method in clinical diagnosis was also investigated.  相似文献   

15.
There is good evidence for cognitive and physiological arousal in chronic insomnia. Accordingly, clinical trial studies of insomnia treatments aimed at reducing arousal, including relaxation and meditation, have reported positive results. Yoga is a multicomponent practice that is also known to be effective in reducing arousal, although it has not been well evaluated as a treatment for insomnia. In this preliminary study, a simple daily yoga treatment was evaluated in a chronic insomnia population consisting of sleep-onset and/or sleep-maintenance insomnia and primary or secondary insomnia. Participants maintained sleep–wake diaries during a pretreatment 2-week baseline and a subsequent 8-week intervention, in which they practiced the treatment on their own following a single in-person training session with subsequent brief in-person and telephone follow-ups. Sleep efficiency (SE), total sleep time (TST), total wake time (TWT), sleep onset latency (SOL), wake time after sleep onset (WASO), number of awakenings, and sleep quality measures were derived from sleep–wake diary entries and were averaged in 2-week intervals. For 20 participants completing the protocol, statistically significant improvements were observed in SE, TST, TWT, SOL, and WASO at end-treatment as compared with pretreatment values.  相似文献   

16.
《Chronobiology international》2012,29(12):1752-1760
ABSTRACT

We compared performance of four popular interpretative algorithms (IAs), i.e., Cole–Kripke, Rescored Cole–Kripke, Sadeh, and UCSD, utilized to derive sleep parameters from wrist actigraphy data. We conducted in-home sleep study of 40 healthy adults (17 female/23 male; age 26.7 ± 12.1 years), assessing sleep variables both by Motionlogger® Micro Watch Actigraphy (MMWA) and Zmachine® Insight+ electroencephalography (EEG). Data of MMWA were separately scored per 30 sec epochs by each of the four popular IAs, and data of the Zmachine were also scored per 30 sec epochs by its proprietary IA. In reference to the EEG Zmachine method, all four of the MMWA algorithms showed high (~94 to 98%) sensitivity and moderate (~42 to 54%) specificity in detecting Sleep epochs. All of them significantly underestimated Sleep Onset Latency (SOL: ~9 to 20 min), and all of them, except the Sadeh IA, significantly underestimated Wake After Sleep Onset (WASO: ~22 to 25 min) and overestimated Total Sleep Time (TST: ~32 to 45 min) and Sleep Efficiency (SE: ~7 to 9%). The Sadeh IA showed significantly smaller bias than the other three IAs in deriving WASO, TST, and SE. Overall, application of ‘Rescoring Rules’ improved performance of the Cole–Kripke IA. The Sadeh and Rescored Cole–Kripke IAs exhibited highest agreement with the EEG Zmachine method (Cohen’s Kappa: ~51%), while the UCSD IA exhibited lowest agreement (Cohen’s kappa: ~47%). However, minimum detectable change across all sleep parameters was smallest with use of the UCSD IA and, except for SOL, largest with use of the Sadeh algorithm. Findings of this study indicate the Sadeh IA is most appropriate for deriving sleep parameters of healthy adults, while the UCSD IA is most appropriate for evaluating change in sleep parameters over time or in response to medical intervention.  相似文献   

17.
Our aim was to measure the correlation between fetal electrocardiographic (FECG) recordings of low-risk pregnancies and polysomnographic (PSG) study parameters in low-risk infants born at term as a measurement of perinatal sleep-development continuity.We designed a short, prospective, observational follow-up of physiologic parameters between fetuses and newborns. We studied 10 fetuses from low-risk pregnant female out-patients and the same subjects as low-risk newborns delivered at term. Fetal state (FS) was defined in FECG recordings reassembling the following: fetal state I (quiet sleep or QS); fetal state II (active sleep or AS); fetal state III (quiet waking), and fetal state IV (active waking). Percentages of AS, QS, and wakefulness in PSG studies of newborns were also determined.Comparisons of FS I with QS showed a significant reduction in QS, while comparison of FS II with AS showed significant reduction in AS. Negative correlations were found between FS I with QS, and FS II with AS. Number of cycles in FECG recordings and PSG sleep cycles also demonstrated significant correlation.In conclusion our data showed partial but significant sleep function continuity from fetal to neonatal period.  相似文献   

18.
BackgroundNormal sleep continuity and architecture show remarkable inter-individual variability. Previous studies suggest that brain morphology may explain inter-individual differences in sleep variables.MethodThirty-eight healthy subjects spent two consecutive nights at the sleep laboratory with polysomnographic monitoring. Furthermore, high-resolution T1-weighted MRI datasets were acquired in all participants. EEG sleep recordings were analyzed using standard sleep staging criteria and power spectral analysis. Using the FreeSurfer software for automated segmentation, 174 variables were determined representing the volume and thickness of cortical segments and the volume of subcortical brain areas. Regression analyses were performed to examine the relationship with polysomnographic and spectral EEG power variables.ResultsThe analysis did not provide any support for the a-priori formulated hypotheses of an association between brain morphology and polysomnographic variables. Exploratory analyses revealed that the thickness of the left caudal anterior cingulate cortex was positively associated with EEG beta2 power (24–32 Hz) during REM sleep. The volume of the left postcentral gyrus was positively associated with periodic leg movements during sleep (PLMS).ConclusionsThe function of the anterior cingulate cortex as well as EEG beta power during REM sleep have been related to dreaming and sleep-related memory consolidation, which may explain the observed correlation. Increased volumes of the postcentral gyrus may be the result of increased sensory input associated with PLMS. However, due to the exploratory nature of the corresponding analyses, these results have to be replicated before drawing firm conclusions.  相似文献   

19.
《Chronobiology international》2013,30(7):1024-1028
Wearable fitness-tracker devices are becoming increasingly available. We evaluated the agreement between Jawbone UP and polysomnography (PSG) in assessing sleep in a sample of 28 midlife women. As shown previously, for standard actigraphy, Jawbone UP had high sensitivity in detecting sleep (0.97) and low specificity in detecting wake (0.37). However, it showed good overall agreement with PSG with a maximum of two women falling outside Bland–Altman plot agreement limits. Jawbone UP overestimated PSG total sleep time (26.6?±?35.3?min) and sleep onset latency (5.2?±?9.6?min), and underestimated wake after sleep onset (31.2?±?32.3?min) (p’s?<?0.05), with greater discrepancies in nights with more disrupted sleep. The low-cost and wide-availability of these fitness-tracker devices may make them an attractive alternative to standard actigraphy in monitoring daily sleep–wake rhythms over several days.  相似文献   

20.
Sleep disruption has been associated with increased risks for several major chronic diseases that develop over decades. Differences in sleep/wake timing between work and free days can result in the development of social jetlag (SJL), a chronic misalignment between a person’s preferred sleep/wake schedule and sleep/wake timing imposed by his/her work schedule. Only a few studies have examined the persistence of SJL or sleep disruption over time. This prospective investigation examined SJL and sleep characteristics over a 2-year period to evaluate whether SJL or poor sleep were chronic conditions during the study period. SJL and sleep measures (total sleep time [TST], sleep onset latency [SOL], wake after sleep onset [WASO]), and sleep efficiency [SE]), were derived from armband monitoring among 390 healthy men and women 21–35 years old. Participants wore the armband for periods of 4–10 days at 6-month intervals during the follow-up period (N = 1431 repeated observations).

The consistency of SJL or sleep disruption over time was analyzed using generalized linear mixed models (GLMMs) for repeated measures. Repeated measures latent class analysis (RMLCA) was then used to identify subgroups among the study participants with different sleep trajectories over time. Individuals in each latent group were compared using GLMMs to identify personal characteristics that differed among the latent groups.

Minor changes in mean SJL, chronotype, or TST were observed over time, whereas no statistically significant changes in SOL, WASO, or SE were observed during the study period. The RMLCA identified two groups of SJL that remained consistent throughout the study (low SJL, mean ± SE: 0.4 ± 0.04 h, 42% of the study population; and high SJL, 1.4 ± 0.03 h, 58%). Those in the SJL group with higher values tended to be employed and have an evening chronotype.

Similarly, two distinct subgroups were observed for SOL, WASO, and SE; one group with a pattern suggesting disrupted sleep over time, and another with a consistently normal sleep pattern. Analyses of TST identified three latent groups with relatively short (5.6 ± 1.0 h, 21%), intermediate (6.5 ± 1.0 h, 44%), and long (7.3 ± 1.0 h, 36%) sleep durations, all with temporally stable, linear trajectories. The results from this study suggest that sleep disturbances among young adults can persist over a 2 year period. Latent groups with poor sleep tended to be male, African American, lower income, and have an evening chronotype relative to those with more normal sleep characteristics. Characterizing the persistence of sleep disruption over time and its contributing factors could be important for understanding the role of poor sleep as a chronic disease risk factor.  相似文献   