首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 125 毫秒
1.
A method for determination of glutathione (GSH) in single human hepatocarcinoma (HH) cells was described by capillary zone electrophoresis with electrochemical detection at a gold/mercury amalgam micro-disk electrode. When HH cells were washed with the running buffer instead of physiological buffer saline, only one electrophoretic peak for GSH is depicted on the electropherograms of single HH cells. When electroosmotic injection of 0.01 mol/l NaOH for lysing the cell introduced into the capillary, the lysis time can be shorten to 5 s. The whole cell injection and no need of derivatization reaction lead more accurate and precise results. The average amount of GSH in an individual HH cell is 22.3+/-5.8 fmol (mean+/-standard deviation), which is consistent with that of its homogenate.  相似文献   

2.
3.
On-line cell lysis of bacteria and its spores using a microfluidic biochip   总被引:1,自引:0,他引:1  
Optimal detection of pathogens by molecular methods in water samples depends on the ability to extract DNA rapidly and efficiently. In this study, an innovative method was developed using a microfluidic biochip, produced by microelectrochemical system technology, and capable of performing online cell lysis and DNA extraction during a continuous flow process. On-chip cell lysis based on chemical/physical methods was performed by employing a sufficient blend of water with the lysing buffer. The efficiency of lysis with microfluidic biochip was compared with thermal lysis in Eppendorf tubes and with two commercial DNA extraction kits: Power Water DNA isolation kit and ForensicGEM Saliva isolation kit in parallel tests. Two lysing buffers containing 1% Triton X-100 or 5% Chelex were assessed for their lysis effectiveness on a microfluidic biochip. SYBR Green real-time PCR analysis revealed that cell lysis on a microfluidic biochip using 5% Chelex buffer provided better or comparable recovery of DNA than commercial isolation kits. The system yielded better results for Gram-positive bacteria than for Gram-negative bacteria and spores of Gram-positive bacteria, within the limits of detection at 103 CFU/ml. During the continuous flow process in the system, rapid cells lysis with PCR-amplifiable genomic DNA were achieved within 20 minutes.  相似文献   

4.
A nanoliter-scale nucleic acid processor with parallel architecture   总被引:6,自引:0,他引:6  
The purification of nucleic acids from microbial and mammalian cells is a crucial step in many biological and medical applications. We have developed microfluidic chips for automated nucleic acid purification from small numbers of bacterial or mammalian cells. All processes, such as cell isolation, cell lysis, DNA or mRNA purification, and recovery, were carried out on a single microfluidic chip in nanoliter volumes without any pre- or postsample treatment. Measurable amounts of mRNA were extracted in an automated fashion from as little as a single mammalian cell and recovered from the chip. These microfluidic chips are capable of processing different samples in parallel, thereby illustrating how highly parallel microfluidic architectures can be constructed to perform integrated batch-processing functionalities for biological and medical applications.  相似文献   

5.
In this paper, the amount of ascorbic acid (AA) in single rat peritoneal mast cell was determined by the method of capillary electrophoresis (CE) with electrochemical detection (ED) at a carbon fiber microdisk bundle electrode. The CE–ED system and the single-cell injection system were rearranged to make the operation more convenient and efficient. In the experiment, a self-made holder made of foam was used to keep the capillary from swing, which kept the stability of the baseline of the electropherogram. The single cell was lysed completely within 5 s using the 0.1% sodium dodecylsulfate (SDS) as the cell lysis solution together with the lysis voltage of 2 kV. The quantitation analysis was accomplished by the use of calibration curves, and the amount of AA in single rat peritoneal mast cell was from 2.4 to 7.1 fmol.  相似文献   

6.
Microfluidic devices allow assays to be performed using minute amounts of sample and have recently been used to control the microenvironment of cells. Microfluidics is commonly associated with closed microchannels which limit their use to samples that can be introduced, and cultured in the case of cells, within a confined volume. On the other hand, micropipetting system have been used to locally perfuse cells and surfaces, notably using push-pull setups where one pipette acts as source and the other one as sink, but the confinement of the flow is difficult in three dimensions. Furthermore, pipettes are fragile and difficult to position and hence are used in static configuration only.The microfluidic probe (MFP) circumvents the constraints imposed by the construction of closed microfluidic channels and instead of enclosing the sample into the microfluidic system, the microfluidic flow can be directly delivered onto the sample, and scanned across the sample, using the MFP. . The injection and aspiration openings are located within a few tens of micrometers of one another so that a microjet injected into the gap is confined by the hydrodynamic forces of the surrounding liquid and entirely aspirated back into the other opening. The microjet can be flushed across the substrate surface and provides a precise tool for localized deposition/delivery of reagents which can be used over large areas by scanning the probe across the surface. In this video we present the microfluidic probe1 (MFP). We explain in detail how to assemble the MFP, mount it atop an inverted microscope, and align it relative to the substrate surface, and finally show how to use it to process a substrate surface immersed in a buffer.Open in a separate windowClick here to view.(47M, flv)  相似文献   

7.
For the quantitative analysis of an unknown sample a calibration curve should be obtained, as analytical instruments give relative, rather than absolute measurements. Therefore, researchers should make standard samples with various known concentrations, measure each standard and the unknown sample, and then determine the concentration of the unknown by comparing the measured value to those of the standards. These procedures are tedious and time-consuming. Therefore, we developed a polymer based microfluidic device from polydimethylsiloxane, which integrates serial dilution and capillary electrophoresis functions in a single device. The integrated microchip can provide a one-step analytical tool, and thus replace the complex experimental procedures. Two plastic syringes, one containing a buffer solution and the other a standard solution, were connected to two inlet holes on a microchip, and pushed by a hydrodynamic force. The standard sample is serially diluted to various concentrations through the microfluidic networks. The diluted samples are sequentially introduced through microchannels by electro-osmotic force, and their laser-induced fluorescence signals measured by capillary electrophoresis. We demonstrate the integrated microchip performance by measuring the fluorescence signals of fluorescein at various concentrations. The calibration curve obtained from the electropherograms showed the expected linearity.  相似文献   

8.
Planar patch clamp has revolutionized characterization of ion channel behavior in drug discovery primarily via advancement in high throughput. Lab use of planar technology, however, addresses different requirements and suffers from inflexibility to enable wide range of interrogation via a single cell. This work presents integration of planar patch clamp with microfluidics, achieving multiple solution exchanges for tailor-specific measurement and allowing rapid replacement of the cell-contacting aperture. Studies via endogenously expressed ion channels in HEK 293T cells were commenced to characterize the device. Results reveal the microfluidic concentration generator produces distinct solution/drug combination/concentrations on-demand. Volume-regulated chloride channel and voltage-gated potassium channels in HEK 293T cells immersed in generated solutions under various osmolarities or drug concentrations show unique channel signature under specific condition. Excitation and blockage of ion channels in a single cell was demonstrated via serial solution exchange. Robustness of the reversible bonding and ease of glass substrate replacement were proven via repeated usage of the integrated device. The present approach reveals the capability and flexibility of integrated microfluidic planar patch-clamp system for ion channel assays.  相似文献   

9.
BACKGROUND: Cytomics aims at understanding the function of cellular systems by analysis of single cells. Recently, there has been a growing interest in single cell measurements being performed in microfluidic systems. These systems promise to integrate staining, measurement, and analysis in a single system. One important aspect is the limitation of allowable cell sizes due to microfluidic channel dimensions. Here we want to demonstrate the broad applicability of microfluidic chip technology for the analysis of many different cell types. METHODS: We have developed a microfluidic chip and measurement system that allows flow cytometric analysis of fluorescently stained cells from different organisms. In this setup, the cells are moved by pressure-driven flow inside a network of microfluidic channels and are analyzed individually by fluorescence detection. RESULTS: We have successfully applied the system to develop a methodology to detect viable and dead cells in yeast cell populations. Also, we have measured short interfering RNA (siRNA) mediated silencing of protein expression in mammalian cells. In addition, we have characterized the infection state of Magnaportae grisea fungal spores. CONCLUSIONS: Results obtained with the microfluidic system demonstrate a broad applicability of microfluidic flow cytometry to measurement of various cell types.  相似文献   

10.
We present a microfluidic platform, which provides a simple and efficient means for handling and processing Pseudo-nitzschia, a neurotoxin-producing marine algae. Currently, analyzing the production of such toxins is complicated by multiple environmental factors and high variability among individual Pseudo-nitzschia species. To address this issue, we developed a device that can precisely trap single and multiple cells for subsequent lysis to extract relevant intracellular molecules. Our results show a cell trapping efficiency of up to 96%, which is achieved by hydrodynamic flow focusing. Additionally, complete cell lysis via ultrasonication can be accomplished within a few seconds. This platform can be applied to other algae and non-algae cell types with minimal modification, thus providing a valuable tool for studying biological intracellular mechanisms at the single and multi-cell level.  相似文献   

11.
This study aimed to demonstrate the feasibility of generating tumor cell vaccine models by single-cell surgery in a microfluidic device that integrates one-to-one electrofusion, shear flow reseparation, and on-device culture. The device was microfabricated from polydimethylsiloxane (PDMS) and consisted of microorifices (aperture size: ∼3 μm) for one-to-one fusion, and microcages for on-device culture. Using the device, we could achieve one-to-one electrofusion of leukemic plasmacytoid dendritic cells (DC-like cells) and Jurkat cells with a fusion efficiency of ∼ 80%. Fusion via the narrow microorifices allowed DC-like cells to acquire cytoplasmic contents of the Jurkat cells while preventing nuclei mixing. After fusion, the DC-like cells were selectively reseparated from the Jurkat cells by shear flow application to generate tumor nuclei-free antigen-recipient DC-like (tarDC-like) cells. When cultured as single cells on the device, these cells could survive under gentle medium perfusion with a median survival time of 11.5 h, although a few cells could survive longer than 36 h. Overall, this study demonstrates single-cell surgery in a microfluidic device for potential generation of dendritic cell vaccines which are uncontaminated with tumor nucleic materials. We believe that this study will inspire the generation of safer tumor cell vaccines for cancer immunotherapy.  相似文献   

12.
目的:探讨低渗法与红细胞裂解法应用于小鼠少量外周血间期核荧光原位杂交(fluorescence in situ hybridization,FISH)检测的优缺点,以便于根据实验条件选取最合适的方法。方法:小鼠剪尾巴法获取外周血,采用低渗法或红细胞裂解法破坏红细胞,涂片前先用免疫组化笔在玻片上划好预计涂片区域,重悬沉淀后稍等片刻再吸中间部分用于涂片,涂完后在相差显微镜下观察密度,行常规FISH,比较两种方法处理后的FISH结果。结果:低渗法和红细胞裂解法处理后的片子背景都较干净,密度适中,信号较强。结论:在外周血间期核荧光原位杂交技术中,低渗法和红细胞裂解法都可以获得较满意的FISH结果。低渗法的特点在于试剂便宜且易于获取,但耗时稍长;而红细胞裂解法的特点在于可节省实验时间,但需专用试剂。  相似文献   

13.
Capillary electrophoresis with laser-induced fluorescence detection was used to separate and detect doxorubicin and at least five metabolites from NS-1 cells that were treated with 25 microM doxorubicin for 8 h. Using 10 mM borate, 10 mM sodium dodecyl sulfate (pH 9.3) as separation buffer, the 488-nm argon-ion laser line for fluorescence excitation, and a 635 +/- 27.5 nm bandpass filter for detection, the limit of detection (S/N=3) for doxorubicin is 61 +/- 13 zmol. This low limit of detection allows for the detection of a larger number of metabolites than previously reported. Two extraction procedures were performed: a bulk liquid-liquid extraction and an in-capillary single-cell lysis. While in the bulk liquid-liquid extraction procedure, recovery for doxorubicin range from 50 to 99%, in single cell analysis the recovery is expected to be complete. Furthermore performing lysis of a single cell inside the separation capillary prevents doxorubicin or metabolite loss or degradation during handling. Based on the bulk method the calculated metabolite abundance is in the sub-amol per cell range while it varies from 0.1 to 1.1 fmol per cell in single cell analysis confirming metabolite loss during handling. Each metabolite was found at a level less than 0.1% of the doxorubicin content in either method, suggesting a slow metabolism in the NS-1 cell system or effective removal of metabolites by the cell.  相似文献   

14.
A method for the direct determination of ascorbic acid (AA) in individual rat hepatocyte based on capillary electrophoresis (CE) coupled with electrochemical detection (ECD) using a new kind of homemade carbon fiber micro-disk bundle electrode has been described. Individual rat hepatocytes were injected into a fused-silica capillary with an inner diameter of 25 microm, and lysed by 0.1% sodium dodecylsulfate (SDS) as cell lysis solution. The following conditions were suitable for the determination of AA: running buffer, 1.83 x 10(-2) mol/l Na2HPO4-1.70 x 10(-3) mol/l NaH2PO4 (pH 7.8); separation voltage, 20.0 kV; detection potential, 0.80 V (vs. saturated calomel electrode (SCE)). The concentration limit of detection (LOD) of the method was 1.7 x 10(-6) mol/l at a signal-to-noise (S/N) ratio of 3, and the mass LOD was 3.0 fmol. The linear dynamic range was from 5.0 x 10(-6) to 5.0 x 10(-4) mol/l with a correlation coefficient of 0.9962 for the injection voltage of 5.0 kV and injection time of 10s. The relative standard deviation (R.S.D.) was 0.85% for the migration time and 1.8% for the peak current. This method was successfully applied to AA determination in rat hepatocyte. The recovery was between 91% and 97%, and the amount of AA in single rat hepatocyte ranged from 28 to 63 fmol.  相似文献   

15.
We present a novel method using flow cytometry–fluorescence in situ hybridization (flow–FISH) to detect specific messenger RNA (mRNA) in suspended cells using locked nucleic acid (LNA)-modified oligonucleotide probes. β-Actin mRNA was targeted in whole A549 epithelial cells by hybridization with a biotinylated, LNA-modified probe. The LNA bound to β-actin was then stained using phycoerythrin-conjugated streptavidin and detected by flow cytometry. Shifts in fluorescence signal intensity between the β-actin LNA probe and a biotinylated, nonspecific control LNA were used to determine optimal conditions for this type of flow–FISH. Multiple conditions for permeabilization and hybridization were tested, and it was found that conditions using 3 μg/ml of proteinase K for permeabilization and 90 min hybridization at 60 °C with buffer containing 50% formamide allow cells containing the LNA-bound mRNA to be detected and differentiated from the control LNA with high confidence (< 14% overlap between curves). This combined method, called LNA flow–FISH, can be used for detection and quantification of other RNA species as well as for telomerase measurement and detection.  相似文献   

16.
We present a simple technique for cell loading, culturing, and phenotypic study in a multi-chamber microfluidic device made of polydimethylsiloxane (PDMS). This technique is based on the use of degassing induced aspiration of PDMS which allows loading cells into micro-cavities within 1 min. A large number of triangle cavities are patterned aside main flow channels with narrow connections so that cells can be loaded by aspirating into each cavity. In our device, high throughput and long-term monitoring can be done with minimum shear force of the flow. As a demonstration, we show a controlled loading at single cell level and the phenotypic variation of gene expression of the yeast strain w303 as a function of copper ion concentration of the medium.  相似文献   

17.
A microfluidic array was constructed for trapping single cell and loading identical dynamic biochemical stimulation for gain a better understanding of Ca2+ signaling at single cell resolution in the present study. This microfluidic array consists of multiple radially aligned flow channels with equal intersection angles, which was designed by a combination of stagnation point flow and physical barrier. Numerical simulation results and trajectory analysis have shown the effectiveness of this single cell trapping device. Fluorescent experiment results demonstrated the effects of flow rate and frequency of dynamic stimulus on the profiles of biochemical concentration which exposed on captured cells. In this microarray, the captured single cells in each trapping channels were able to receive identical extracellular dynamic biochemical stimuli which being transmitted from the entrance in the middle of the microfluidic array. Besides, after loading dynamic Adenosine Triphosphate (ATP) stimulation on captured cells by this device, consistent average intracellular Ca2+ dynamics phase and cellular heterogeneity were observed in captured single K562 cells. Furthermore, this device is able to be used for investigating cellular respond on single cell resolution to temporally varying environments by modulating the stimulation signal in terms of concentration, pattern, and duration of exposure.  相似文献   

18.
19.
We present a microfluidic device that enables the quantitative determination of intracellular biomolecules in multiple single cells in parallel. For this purpose, the cells are passively trapped in the middle of a microchamber. Upon activation of the control layer, the cell is isolated from the surrounding volume in a small chamber. The surrounding volume can then be exchanged without affecting the isolated cell. However, upon short opening and closing of the chamber, the solution in the chamber can be replaced within a few hundred milliseconds. Due to the reversibility of the chambers, the cells can be exposed to different solutions sequentially in a highly controllable fashion, e.g. for incubation, washing, and finally, cell lysis. The tightly sealed microchambers enable the retention of the lysate, minimize and control the dilution after cell lysis. Since lysis and analysis occur at the same location, high sensitivity is retained because no further dilution or loss of the analytes occurs during transport. The microchamber design therefore enables the reliable and reproducible analysis of very small copy numbers of intracellular molecules (attomoles, zeptomoles) released from individual cells. Furthermore, many microchambers can be arranged in an array format, allowing the analysis of many cells at once, given that suitable optical instruments are used for monitoring. We have already used the platform for proof-of-concept studies to analyze intracellular proteins, enzymes, cofactors and second messengers in either relative or absolute quantifiable manner.  相似文献   

20.
Abolmaaty A  Vu C  Oliver J  Levin RE 《Microbios》2000,101(400):181-189
A new lysis solution designated TZ, consisting of 2.0% Triton X-100 plus 2.5 mg sodium azide/ml in 0.1 M Tris-HCl buffer at pH 8.0, yielded higher levels of genomic DNA from Escherichia coli O157:H7 cells compared with a number of other commonly used cell lysis methods. Ethidium bromide stained DNA bands resulting from PCR amplification of target DNA from 100 CFU of E. coli O157:H7 were readily detected following electrophoresis of agarose gels. In contrast, conventional cell lysis methods failed to detect target DNA from 100 CFU after PCR amplification. The new solution was highly effective for lysing cell suspensions of Salmonella enteritidis, Pseudomonas putida, Lysteria monocytogenes and Psychrobacter immobilis.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号