首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
High-throughput quantitative analytical method for plant N-glycan has been developed. All steps, including peptide N-glycosidase (PNGase) A treatment, glycan preparation, and exoglycosidase digestion, were optimized for high-throughput applications using 96-well format procedures and automatic analysis on a DNA sequencer. The glycans of horseradish peroxidase with plant-specific core α(1,3)-fucose can be distinguished by the comparison of the glycan profiles obtained via PNGase A and F treatments. The peaks of the glycans with (91%) and without (1.2%) α(1,3)-fucose could be readily quantified and shown to harbor bisecting β(1,2)-xylose via simultaneous treatment with α(1,3)-mannosidase and β(1,2)-xylosidase. This optimized method was successfully applied to analyze N-glycans of plant-expressed recombinant antibody, which was engineered to contain a minor amount of glycan harboring β(1,2)-xylose. These results indicate that our DNA sequencer-based method provides quantitative information for plant-specific N-glycan analysis in a high-throughput manner, which has not previously been achieved by glycan profiling based on mass spectrometry.  相似文献   

2.
Rapid resolution liquid chromatography/tandem multi-stage mass spectrometry (RRLC-MS(n)) and rapid resolution liquid chromatography/tandem mass spectrometry (RRLC/MS/MS) methods were developed for the identification and quantification of ergosterol and its metabolites from rat plasma, urine and faeces. Two metabolites (ERG1 and ERG2) were identified by RRLC/MS(n). The concentrations of the ergosterol were determined by RRLC/MS/MS. The separation was performed on an Agilent Zorbax SB-C18 with the mobile phase consisting of methanol and water (containing 0.1% formic acid). The detection was carried out by means of atmospheric pressure chemical ionization mass spectrometry in positive ion mode with multiple reaction monitoring (MRM). Linear calibration curves were obtained in the concentration range of 7-2000, 6-2000 and 8-7500 ng/mL for plasma, urine and faecal homogenate, respectively. The intra- and inter-day precision values (RSD) were below 10%. The method was applied to the pharmacokinetic properties and elimination pathway of ergosterol in rats.  相似文献   

3.
We describe an integrated workstation for the automated, high-throughput, and conclusive identification of proteins by reverse-phase chromatography electrospray ionization tandem mass spectrometry. The instrumentation consists of a refrigerated autosampler, a submicrobore reverse-phase liquid chromatograph, and an electrospray triple quadrupole mass spectrometer. For protein identification, enzymatic digests of either homogeneous polypeptides or simple protein mixtures were generated and loaded into the autosampler. Samples were sequentially injected every 32 min. Ions of eluting peptides were automatically selected by the mass spectrometer and subjected to collision-induced dissociation. Following each run, the resulting tandem mass spectra were automatically analyzed by SEQUEST, a program that correlates uninterpreted peptide fragmentation patterns with amino acid sequences contained in databases. Protein identification was established by SEQUEST_SUMMARY a program that combines the SEQUEST scores of peptides originating from the same protein and ranks the cumulative results in a short summary. The workstation's performance was demonstrated by the unattended identification of 90 proteins from the yeast Saccharomyces cerevisiae, which were separated by high-resolution two-dimensional PAGE. The system was found to be very robust and identification was reliably and conclusively established for proteins if quantities exceeding 1-5 pmol were applied to the gel. The level of automation, the throughput, and the reliability of the results suggest that this system will be useful for the many projects that require the characterization of large numbers of proteins.  相似文献   

4.
An on-line reversed-phase (RP) high-performance liquid chromatography/mass spectrometry (MS) method has been developed for profiling and characterizing N-glycans from recombinant immunoglobulin G antibodies. In this method, released N-glycans are derivatized at their reducing end with 2-aminobenzamide (2AB) and separated on a RP column with on-line fluorescence and MS detection. The method achieves good resolution of all major glycans and segregates glycan types (high-mannose, hybrid, and complex) to different regions of the chromatogram, thus allowing accurate quantification of N-glycans from the fluorescent signal alone. Moreover, the mobile phase used allows high quality on-line MS detection. The 2AB-labeled N-glycans demonstrate good ionization efficiency in electrospray and generate primarily doubly charged [M+2H](2+) ions. The mass and structural information can be readily obtained from the on-line MS and tandem MS data. As little as 70 fmol glycan species can be detected and identified.  相似文献   

5.
In the field of proteomic investigation, the analysis of membrane proteins still faces many technical challenges. A fundamental question in this puzzle is how to maintain a proper solvent environment to allow the hydrophobic proteins to remain solubilized. We propose that the denaturation of membrane proteins in a highly concentrated urea solution enables them to be ionized such that ionic exchange chromatography can be employed to separate them. The membrane proteins prepared from the mouse liver were dissolved in 6M guanidine hydrochloride, 20mM Tris-HCl, pH 9.0, and loaded onto a tandem chromatography apparatus coupled with Q-Sepharose FF and Sephacryl S-200HR. These columns were able to adsorb 97.87% of the membrane protein preparations. Using a linear NaCl (0-1.0M) gradient, the bound proteins were eluted out at 0.1-1.0M NaCl, and examined by SDS-PAGE. Furthermore the protein bands underwent excision and digestion with trypsin, followed by reverse-phase chromatography for the separation of the digested peptides and ionic-trap mass spectrometry for the identification of the proteins. From the SDS-PAGE gels, the overlap between proteins from neighboring bands was only 21.34%, indicating that the anionic-size exclusion coupling chromatography efficiently separated these membrane proteins. Of a total of 392 proteins identified, 306 were membrane proteins or membrane-associated proteins. Based on the calculation of hydrophobicity, the GRAVY scores of 83 proteins are greater than, or equal to, 0.00. Taking all of this evidence together, our results revealed that this approach is satisfactory for studies on the membrane proteome from the mouse liver.  相似文献   

6.
Immunoglobulin M is an especially important product of the immune system because it plays a critical role in early protection against infections. In this report, the glycosylation pattern of the protective murine monoclonal IgM 12A1 to Cryptococcus neoformans polysaccharide was analyzed by high-performance liquid chromatography coupled with electrospray ionization mass spectrometry. Peptide mapping studies covering 88% of the deduced amino acid sequence indicated that of the six potential N-glycosylation sites in this antibody only five were utilized, as the tryptic peptide derived from monoclonal IgM 12A1 containing Asn-260 was recovered without carbohydrates. The oligosaccharide side chains of monoclonal IgM 12A1 were characterized at each of the N-glycosylation sites. Asn-166 possessed 20 monosialylated and nonsialylated, and fucosylated and nonfucosylated complex- and hybrid-type oligosaccharides and one high-mannose-type oligosaccharide. Thirteen oligosaccharides were attached to the site at Asn-401, including six complex-type, four hybrid-type, and three high-mannose-type oligosaccharides. Twelve hybrid-type oligosaccharides were attached to Asn-378, three of which had terminal sialic acids. Eleven hybrid-type oligosaccharides were attached to Asn-331, seven of which had terminal sialic acids. Only two high-mannose type oligosaccharides were attached to Asn-363. These results indicated great complexity in the structure and composition of oligosaccharides attached to individual IgM glycosylation sites.  相似文献   

7.
In the studies of lipid metabolomics, liquid chromatography electrospray ionization mass spectrometry (LC/MS) is a robust and popular technique. Although effective reverse-phase LC methods enabling the separation of phospholipid molecular species have been developed, there are still problems with the separation of phosphatidic acid (PA) and phosphatidylserine (PS). These acidic phospholipids often elute as extensively broad peaks, causing inferior separation, detection, and quantification-a severe limitation of the method. In this study, we have developed reverse-phase LC conditions that reduce the undesired peak tailings in the elution profiles of both PA and PS, by using a starting mobile phase containing a low concentration of phosphoric acid (5 microM) and a high percentage of water (40%). Our method sensitively analyzes PA, PS, and their lysoforms, as well as the other phospholipids within a biological sample, in a single chromatographic step by an LC/MS method and, thus, is suitable for lipidomics.  相似文献   

8.
Evaluation of cellular processes and their changes at the level of protein expression and post-translational modifications may allow identification of novel proteins and the mechanisms involved in pathogenic processes. However, the number of proteins and, after tryptic digestion, of peptides from a single cell can be tremendously high. Separation and analysis of such complex peptide mixtures can be performed using multidimensional separation techniques such as two-dimensional gel electrophoresis or two-dimensional-high-performance liquid chromatography (2-D-HPLC). The aim of this work was to establish a fully automated on-line 2-D-HPLC separation method with column switching for the separation of complex tryptic digests. A model mixture of five proteins as well as a nuclear matrix protein sample were digested with trypsin and separated using a strong cation exchange (SCX) column in the first dimension and nano reversed phase in the second dimension. Separated peptides were detected using an ion trap mass spectrometer. The advantages of this new fully automated method are rapid sample loading, the possibility of injecting large volumes and no introduction of salt into the mass spectrometer. Furthermore, column switching allows the independent control and optimization of the two dimensions independently.  相似文献   

9.
A rapid method has been developed to analyse for firocoxib (FIRO) residue in bovine milk. Milk samples were extracted with acetonitrile and sample extracts were purified on Evolute? ABN solid phase extraction cartridges. Aliquots were analysed by rapid resolution liquid chromatography tandem mass spectrometry (RRLC–MS/MS). The method was validated in bovine milk, according to the criteria defined in Commission Decision 2002/657/EC. The decision limit (CCα) was 1.18 ng/mL and for the detection capability a (CCβ) value of 2.02 ng/mL was obtained. The measurement uncertainty of the method was 27%. Fortifying bovine milk samples (n = 18) in three separate assays, show the accuracy of the method to be between 96 and 105%. The precision of the method, expressed as RSD values for the within-lab reproducibility at the three levels of fortification (5, 7.5 and 10 ng/mL) was less than 11% respectively.  相似文献   

10.
Lipopolysaccharide (LPS)-binding proteins interact with LPS in human serum and mediate various immune responses. We describe a high-throughput LPS-binding protein profiling platform for discovering unknown LPS-binding proteins and potential inflammatory mediators. As a pull-down method, the LPS molecules were immobilized onto epoxy beads and then directly incubated with human serum to screen LPS-binding proteins. Through the "untargeted" mass spectrometric approach, potential LPS-binding proteins which elicit various immune responses in human serum were identified by a highly sensitive LTQ Orbitrap Hybrid Fourier Transform Mass Spectrometer (LTQ Orbitrap FT MS). Therefore, this mass spectrometry (MS)-based profiling method is straightforward for screening unknown LPS-binding proteins and provides physiologically relevant binding partners in human serum.  相似文献   

11.
Modeling of metabolic networks as part of systems metabolic engineering requires reliable quantitative experimental data of intracellular concentrations. The hydrophilic interaction liquid chromatography–electrospray ionization–tandem mass spectrometry (HILIC–ESI–MS/MS) method was used for quantitative profiling of more than 50 hydrophilic key metabolites of cellular metabolism. Without prior derivatization, sugar phosphates, organic acids, nucleotides, and amino acids were measured under alkaline and acidic mobile phase conditions with pre-optimized multiple reaction monitoring (MRM) transitions. Irrespective of the polarity mode of the acquisition method used, alkaline conditions achieved the best quantification limits and linear dynamic ranges. Fully 90% of the analyzed metabolites presented detection limits better than 0.5 pmol (on column), and 70% presented 1.5-fold higher signal intensities under alkaline mobile phase conditions. The quality of the method was further demonstrated by absolute quantification of selected metabolites in intracellular extracts of Escherichia coli. In addition, quantification bias caused by matrix effects was investigated by comparison of calibration strategies: standard-based external calibration, isotope dilution, and standard addition with internal standards. Here, we recommend the use of alkaline mobile phase with polymer-based zwitterionic hydrophilic interaction chromatography (ZIC–pHILIC) as the most sensitive scenario for absolute quantification for a broad range of metabolites.  相似文献   

12.
A platform using reverse-phase liquid chromatography coupled to tandem mass spectrometry was developed to measure 28 metabolites from photosynthetic metabolism. It was validated by comparison with authentic standards, with a requirement for distinct and clearly separated peaks, high sensitivity and repeatability in Arabidopsis rosette extracts. The recovery of authentic standards added to the plant material before extraction was 80–120%, demonstrating the reliability of the extraction and analytic procedures. Some metabolites could not be reliably measured, and were extracted and determined by other methods. Measurements of 37 metabolites in Arabidopsis rosettes after 15 min of illumination at different CO2 concentrations showed that most Calvin cycle intermediates remain unaltered, or decrease only slightly (<30%), at compensation point CO2, whereas dedicated metabolites in end-product synthesis pathways decrease strongly. The inhibition of end-product synthesis allows high levels of metabolites to be retained in the Calvin cycle to support a rapid cycle with photorespiration.  相似文献   

13.
It has become evident that the mystery of life will not be deciphered just by decoding its blueprint, the genetic code. In the life and biomedical sciences, research efforts are now shifting from pure gene analysis to the analysis of all biomolecules involved in the machinery of life. One area of these postgenomic research fields is proteomics. Although proteomics, which basically encompasses the analysis of proteins, is not a new concept, it is far from being a research field that can rely on routine and large-scale analyses. At the time the term proteomics was coined, a gold-rush mentality was created, promising vast and quick riches (i.e., solutions to the immensely complex questions of life and disease). Predictably, the reality has been quite different. The complexity of proteomes and the wide variations in the abundances and chemical properties of their constituents has rendered the use of systematic analytical approaches only partially successful, and biologically meaningful results have been slow to arrive. However, to learn more about how cells and, hence, life works, it is essential to understand the proteins and their complex interactions in their native environment. This is why proteomics will be an important part of the biomedical sciences for the foreseeable future. Therefore, any advances in providing the tools that make protein analysis a more routine and large-scale business, ideally using automated and rapid analytical procedures, are highly sought after. This review will provide some basics, thoughts and ideas on the exploitation of matrix-assisted laser desorption/ ionization in biological mass spectrometry – one of the most commonly used analytical tools in proteomics – for high-throughput analyses.  相似文献   

14.
Soy-containing foods and dietary supplements are widely consumed for putative health benefits (e.g., cancer chemoprevention, beneficial effects on serum lipids associated with cardiovascular health, reduction of osteoporosis, relief of menopausal symptoms). However, studies of soy isoflavones in experimental animals suggest possible adverse effects as well (e.g., enhancement of reproductive organ cancer, modulation of endocrine function, anti-thyroid effects). This paper describes the development and validation of a sensitive high throughput method for quantifying isoflavones in blood from experimental animal and human studies. Serum samples containing genistein, daidzein, and equol were processed using reverse phase solid-phase extraction in the 96-well format for subsequent LC-ES/MS/MS or LC-ES/MS analysis using isotope dilution in conjunction with labeled internal standards. The method was validated by repetitive analysis of spiked blank serum and the intra-day and inter-day accuracy (88-99%) and precision (relative standard deviations from 3 to 13%) of measurement determined. The lower limit of quantification for all isoflavones was approximately 0.005 micro M using MS/MS detection, and 0.03 micro M using MS for genistein and daidzein. The degree of method performance, with respect to throughput, sensitivity and selectivity, makes this approach practical for analysis of large sample sets generated from mechanistic animal studies and human clinical trials of soy isoflavones.  相似文献   

15.
We report an ultrahigh-performance liquid chromatography tandem mass spectrometry (UHPLC–MS/MS) method to quantify all-trans-retinal in biological samples of limited size (15–35 mg), which is especially advantageous for use with adipose. To facilitate recovery, retinal and the internal standard 3,4-didehydroretinal were derivatized in situ into their O-ethyloximes. UHPLC resolution combined with high sensitivity and specificity of MS/MS allowed quantification of retinal-O-ethyloximes with a 5-fmol lower limit of detection and a linear range from 5 fmol to 1 pmol. This assay revealed that extraocular concentrations of retinal range from approximately 2 to 40 pmol/g in multiple tissues—the same range as all-trans-retinoic acid. All-trans-retinoic acid has high affinity (kd ? 0.4 nM) for its nuclear receptors (RARα, -β, and -γ), whereas retinal has low (if any) affinity for these receptors, making it unlikely that these retinal concentrations would activate RAR. We also show that the copious amount of vitamin A used in chow diets increases retinal in adipose depots 2- to 5-fold relative to levels in adipose of mice fed a vitamin A-sufficient diet, as recommended for laboratory rodents. This assay also is proficient for quantifying conversion of retinol into retinal in vitro and, therefore, provides an efficient method to study metabolism of retinol in vivo and in vitro.  相似文献   

16.
The tissue distribution of folate in its numerous coenzyme forms may influence the development of disease at different sites. For instance, the susceptibility of human colonic mucosa to localized folate deficiency may predispose to the development of colorectal cancer. We report a sensitive and robust ultra high-performance liquid chromatography (UHPLC) tandem mass spectrometry method for quantifying tissue H4folate, 5-CH3-H4folate, 5-CHO-H4folate, folic acid, and 5,10-CH+-H4folate concentration. Human colonic mucosa (20–100 mg) was extracted using lipase and conjugase enzyme digestion. Rapid separation of analytes was achieved on a UHPLC 1.9-μm C18 column over 7 min. Accurate quantitation was performed using stable isotopically labeled (13C5) internal standards. The instrument response was linear over physiological concentrations of tissue folate (R2 > 0.99). Limits of detection and quantitation were less than 20 and 30 fmol on column, respectively, and within- and between-run imprecision values were 6–16%. In colonic mucosal samples from 73 individuals, the average molar distribution of folate coenzymes was 58% 5-CH3-H4folate, 20% H4folate, 18% formyl-H4folate (sum of 5-CHO-H4folate and 5,10-CH+-H4folate), and 4% folic acid. This assay would be useful in characterizing folate distribution in human and animal tissues as well as the role of deregulated folate homeostasis on disease pathogenesis.  相似文献   

17.
The newly developed SMART Digest™ kit was applied for the sample preparation of human immunoglobulin G1 (hIgG1) in rat serum prior to qualitative and quantitative analyses by liquid chromatography tandem mass spectrometry (LC–MS/MS). The sequence coverages obtained for the light and heavy chains of hIgG1A were 50 and 76%, respectively. The calibration curve was linear from 1.00 to 1000 μg/ml for three of four generic peptides. Overall, the SMART Digest™ kit resulted in similar quantitative data (linearity, sensitivity, accuracy, and precision) compared with the pellet digestion protocol. However, the SMART Digest™ required only 2 h of sample preparation with fewer reagents.  相似文献   

18.
High-performance liquid chromatography with on-line electrospray ionization mass spectrometry (ESI-LC/MS) was investigated for the analysis of carbohydrate heterogeneity using RNase B as a model glycoprotein. Oligosaccharides released from RNase B with endoglycosidase H were reduced and separated on a graphitized carbon column (GCC). GCC-HPLC/MS in the positive-ion mode was successful in the identification of one Man5GlcNAc, three Man6GlcNAc, three Man7GlcNAc, three Man8GlcNAc, one Man9GlcNAc, and an oligosaccharide having six hexose units (Hex) and two N-acetylhexosamine units (HexNAc). The branch structures of the three Man7GlcNAc isomers were determined by liquid chromatography with tandem mass spectrometry (LC/MS/MS). LC/MS/MS analysis was shown to be useful for the detection and identification of a trace amount of Hex6HexNAc2 alditol as a hybrid-type oligosaccharide. Its structure was confirmed by the combination of LC/MS with enzymatic digestion using beta-galactosidase and N-acetyl-beta-glucosaminidase. The relative quantities of high-mannose-type oligosaccharides in RNase B detected by ESI-LC/MS are in reasonable agreement with those by UV, high-pH anion-exchange chromatography with pulsed amperometric detection, fluorophore-assisted carbohydrate electrophoresis. Our results indicate that LC/MS and LC/MS/MS can be utilized to elucidate the distribution of oligosaccharides and their structures, which differ in molecular weight, sugar sequence, and branch structure.  相似文献   

19.
A highly sensitive and specific method of rapid resolution liquid chromatography tandem mass spectrometry (RRLC-MS/MS) in positive ionization mode has been developed and validated for pharmacokinetic study of puerarin in rat plasma. Chromatography was carried out on a Zorbax XDB C18 reversed-phase column using a mobile phase comprising a mixture of methanol and 0.05% acetic acid in water (35:65, v/v) with a flow rate of 0.3 mL/min from 0 min to 5.4 min and then 0.6 mL/min from 5.41 min to 12 min. The mass spectrometer operated in ESI positive ionization mode. Multiple reaction monitoring (MRM) was used to measure puerarin and tectoridin (internal standard). The method was sensitive with a detection limit of 0.33 ng/mL. A good linear response was observed over a range of 10-2000 ng/mL in rat plasma. The inter- and intra-day precision ranged from 2.97% to 7.52% and accuracy from 93.70% to 101.60%. This validated method was applied successfully to a pharmacokinetic study in rat plasma after intravenous administration of puerarin. The main pharmacokinetic parameters were as follows: AUC(0→t) 45.37±13.19 (mgh/L), AUC(0→∞) 47.03±14.78 (mgh/L), MRT 1.03±0.46 (h), T(1/2) 1.31±0.31 (h), V(ss) 0.09±0.02 (L), V(z) 0.17±0.04 (L), Cl 0.10±0.04 (L/h).  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号