首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 140 毫秒
1.
Plasmonics - In this study, we propose a silver-coated (SPR—surface plasmon resonance)-based biosensor for the detection of diesel adulteration for the first time in the field of biosensing....  相似文献   

2.
We present a new approach to surface plasmon microscopy with high refractive index sensitivity and spatial resolution that is not limited by the propagation length of surface plasmons. It is based on a nanostructured metallic sensor surface supporting Bragg-scattered surface plasmons. We show that these non-propagating surface plasmon modes are excellently suited for spatially resolved observations of refractive index variations on the sensor surface owing to their highly confined field profile perpendicular to as well as parallel to the metal interface. The presented theoretical study reveals that this approach enables reaching similar refractive index sensitivity as regular surface plasmon resonance (SPR) microscopy and offers the advantage of improved spatial resolution when observing dielectric features with lateral size <10???m for the wavelength around 800?nm and gold as the SPR-active metal. This paper demonstrates the potential of Bragg-scattered surface plasmon microscopy for high-throughput SPR biosensing with high-density microarrays.  相似文献   

3.
Surface Plasmon Resonance Imaging Sensors: A Review   总被引:1,自引:0,他引:1  
Surface plasmon resonance (SPR) imaging sensors realize label-free, real-time, highly sensitive, quantitative, high-throughput biological interaction monitoring and the binding profiles from multi-analytes further provide the binding kinetic parameters between different biomolecules. In the past two decades, SPR imaging sensors found rapid increasing applications in fundamental biological studies, medical diagnostics, drug discovery, food safety, precision measurement, and environmental monitoring. In this paper, we review the recent advances of SPR imaging sensor technology towards high-throughput multi-analyte screening. Finally, we describe our multiplex spectral-phase SPR imaging biosensor for high-throughput biosensing applications.  相似文献   

4.
A new and exciting biosensing avenue based on assessment of the non-monotonous, concentration dependent effect of pore formation is discussed. A novel kinetic model is advanced to relate surface plasmon resonance (SPR) data with actual concentrations of interacting partners. Lipid modified L1 sensor chip provide the accessible platform for SPR exploration of peptide–membrane interaction, with POPC and melittin as model systems. We show that quantitative assessment of the interaction between an antimicrobial peptide and lipid modified sensors is capable to provide both sensing avenues and detailed mechanistic insights into effects of pore-forming compounds. The proposed model combined with appropriate design of the experimental protocol adds a new depth to the classic SPR investigation of peptide–lipid interaction offering a quantitative platform for detection, improved understanding of the manifold facets of the interaction and for supporting the controlled design of novel antimicrobial compounds. This biosensing approach can be applied to an entire set of pore-forming compounds including antimicrobial peptides and exo-toxins.  相似文献   

5.
Plasmonics - Surface plasmon resonance (SPR)-based biosensing is an accurate and sensitive technique used to evaluate the biomolecular interactions in real time in a label-free environment. Several...  相似文献   

6.
《New biotechnology》2015,32(5):473-484
Although the phenomenon of surface plasmon resonance (SPR) is known for more than a century now, traditional prism-based SPR platforms have hardly escaped the research laboratories despite being recognized for the sensitive and specific performance. Significant efforts have been made over the last years to overcome their existing limitations by coupling the SPR phenomenon to the fiber optic (FO) technology. While this platform has been promoted as cost-effective and simpler alternative capable of handling label-free bioassays, quantification and real-time monitoring of biomolecular interactions, examples of its applicability in sensing and biosensing remain to date very limited. The FO-SPR system is still in development and requires further advancements for reaching the stability and sensitivity of the benchmark SPR systems. Among existing strategies for device improvement, those based on modifying the FO tips using nanomaterials are mostly studied. These small-scale objects provide a wide range of possibilities for alternating the architecture of the FO sensitive zone, enabling also unique effects such as localized SPR (LSPR). This mini-review summarizes the latest innovations in the fabrication procedures which use nanoparticles or other nanomaterials, aiming at FO-SPR technology performance improvements, as well as addition of new device features and functionalities.  相似文献   

7.
Plasmonics - Surface plasmon resonance (SPR) for biosensing was demonstrated 30&nbsp;years ago. In the present contribution, its general background is described together with the necessary...  相似文献   

8.
We report a new high-throughput surface plasmon resonance (SPR) sensor based on combination of SPR imaging with polarization contrast and a spatially patterned multilayer SPR structure. We demonstrate that this approach offers numerous advantageous features including high-contrast SPR images suitable for automated computer analysis, minimum crosstalk between neighboring sensing channels and inherent compensation for light level fluctuations. Applications of a laboratory prototype of the high-throughput SPR sensor with 108 sensing channels for refractometry and biosensing are described. In refractometric experiments, the noise-limited refractive index resolution of the system has been established to be 3 x 10(-6) refractive index unit (RIU). Experimental data on detection of human choriogonadotropin (hCG) suggest that in conjunction with monoclonal antibodies against hCG, the reported SPR imaging sensor is capable of detecting hCG at concentrations lower than 500 ng/ml.  相似文献   

9.
Surface plasmons resonance (SPR) architectures based on grating coupler/disperser combination is an attractive alternative for spectral-based biochemical sensing. In this paper, we investigate theoretically and experimentally a new concept where the plasmon coupling occurs through a thin film grating and sensing occurs via the first evanescent diffraction order in transmitive mode. The surface plasmon wave excitation induces a peak in the wavelength as well as in the angular spectra of the detected first transmitted diffraction order. Accordingly, a change in SPR spectrum of the detected diffraction order can be used to quantify the amount of the target molecules immobilized on the sensor surface, and therefore, the concentration of these molecules in the analyte solution. The developed sensor architecture is dedicated to droplet biochemical sensing and appears to be especially suitable for biosensor integration and miniaturization. The presented sensor concept is perfectly suited for mass production of low-cost and reproducible SPR sensor chip for biochemical analysis. The implemented setup gives access to multichannel biosensing with the potential for efficient internal referencing essential to achieve sufficiently high reproducibility and accuracy of the measurements.  相似文献   

10.
Sensors based on surface plasmon resonance (SPR) allow rapid, label-free, highly sensitive detection, and indeed this phenomenon underpins the only label-free optical biosensing technology that is available commercially. In these sensors, the existence of surface plasmons is inferred indirectly from absorption features that correspond to the coupling of light into a thin metallic film. Although SPR is not intrinsically a radiative process, when the metallic coating which support the plasmonic wave exhibits a significant surface roughness, the surface plasmon can itself couple to the local photon states, and emit light. Here we show that using silver coated optical fibres, this novel SPR transducing mechanism offers significant advantages compare to traditional reflectance based measurements such as lower dependency on the metallic thickness and higher signal to noise ratio. Furthermore, we show that more complex sensor architectures with multiple sensing regions scattered along a single optical fibre enable multiplexed detection and dynamic self referencing of the sensing signal. Moreover, this alternative approach allows to combine two different sensing technologies, SPR and fluorescence sensing within the same device, which has never been demonstrated previously. As a preliminary proof of concept of potential application, this approach has been used to demonstrate the detection of the seasonal influenza A virus.  相似文献   

11.
表面等离子体共振(surface plasmon resonance,SPR)技术作为一种新型的免标记、实时在线研究生物分子间相互作用的高灵敏传感技术,已经在生命科学领域中得到了大量应用。该文简要介绍了SPR生物传感器的基本原理,重点评述了其在新药筛选和药物作用机制方面的研究进展,并对其前景进行了展望。  相似文献   

12.
Surface plasmon resonance (SPR) is a powerful technique for measuring molecular interaction in real-time. SPR can be used to detect molecule to cell interactions as well as molecule to molecule interactions. In this study, the SPR-based biosensing technique was applied to real-time monitoring of odorant-induced cellular reactions. An olfactory receptor, OR I7, was fused with a rho-tag import sequence at the N-terminus of OR I7, and expressed on the surface of human embryonic kidney (HEK)-293 cells. These cells were then immobilized on a SPR sensor chip. The intensity of the SPR response was linearly dependent on the amount of injected odorant. Among all the aldehyde containing odorants tested, the SPR response was specifically high for octanal, which is the known cognate odorant for the OR I7. This SPR response is believed to have resulted from intracellular signaling triggered by the binding of odorant molecules to the olfactory receptors expressed on the cell surface. This SPR system combined with olfactory receptor-expressed cells provides a new olfactory biosensor system for selective and quantitative detection of volatile compounds.  相似文献   

13.
SPR biosensing coupled to a digital microfluidic microstreaming system   总被引:1,自引:0,他引:1  
This article reports on a proof-of-concept system composed of a droplet based surface plasmon resonance (SPR) system coupled to a surface acoustic wave (SAW) microfluidic plateform. It is now well established that surface based binding analyses such as SPR are highly influenced by the transport of analyte to the sensing surface. Further, obtaining reliable equilibrium in flow cells to realize quantification studies is not straightforward. An original solution compared to generally used pressure driven flows is then proposed to favourably cope with these issues. Efficiency of SAW microstreaming coupled to SPR biosensing is considered, in order to improve the accuracy of kinetic parameter estimation in mass transport limited regime and to realize reliable quantification studies. First, the droplet based SPR technique and its advantages are presented. Then, the integration of the microstreaming on the system is discussed. Streptavidin binding is then monitored in static mode and under SAW streaming mode.  相似文献   

14.
Functionalization of a gold surface is usually accomplished by covalent binding via self-assembled monolayers (SAMs) on the gold surface, followed by attachment of flexible polymeric linker layers such as dextran hydrogels. However, these techniques require multiple steps and also have nonspecific interactions and steric problems. In this study, a self-assembled carboxylated terthiophene monolayer was formed onto a gold surface to create a sensitive and stable surface plasmon resonance (SPR) biosensing system. Compared with a commercial carboxymethyl dextran chip (CM5), the terthiophene SAM surface provided more than six times more antibody-binding signals and nearly three times the SPR assay sensitivity for progesterone (P4).  相似文献   

15.
Large area monolayer of self-assembled polystyrene sphere (PS) arrays were formed by an interface self-assembly method and the gap of PS was adjusted by O2 plasma treatment (OPT). After different duration of OPT, the spacing between the PSs varied from 5 to 88 nm. Then, 20 nm Au film was deposited on the PS arrays by electron beam deposition. The absorption peaks of Au-coated PS array red-shifted obviously by changing the gap of PS. The new absorption peaks emerged when the gap of the PS decreased to about 20 nm. The surface plasmon resonance (SPR) was employed to explain the absorption proportion of this Au-PS structure. These micro-nano structures exhibit tunable SPR bands, which may be useful to the applications in some research fields, such as biosensing, single molecule detection, and novel optoelectronic devices.  相似文献   

16.
An absorption-based surface plasmon resonance (SPR(Abs)) biosensor probe has been developed for simple and reproducible measurements of hydrogen peroxide using a modified Trinder's reagent (a chromogenic reagent). The reagent enabled the determination of the hydrogen peroxide concentration by the development of deep color dyes (lambda(max)=630nm) through the oxidative coupling reaction with N-ethyl-N-(2-hydroxy-3-sulfopropyl)-3,5-dimethylaniline sodium salt monohydrate (MAOS; C(13)H(20)NNaO(4)S.H(2)O) and 4-aminoantipyrine (4-AA) in the presence of hydrogen peroxide and horseradish peroxidase (HRP). In the present study, urea as an adduct of hydrogen peroxide for color development could be omitted from the measurement solution. The measurement solution containing 5mM hydrogen peroxide was deeply colored at a high absorbance value calculated as 46.7cm(-1) and was directly applied to the SPR(Abs) biosensing without dilution. The measurement was simply performed by dropping the measurement solution onto the surface of the SPR sensor probe, and the SPR(Abs) biosensor response to hydrogen peroxide was obtained as a reflectivity change in the SPR spectrum. After investigation of the pH profiles in the SPR(Abs) biosensor probe, a linear calibration curve was obtained between 1.0 and 50mM hydrogen peroxide (r=0.991, six points, average of relative standard deviation; 0.152%, n=3) with a detection limit of 0.5mM. To examine the applicability of this SPR(Abs) biosensor probe, 20mM glucose detection using glucose oxidase was also confirmed without influence of the refractive index in the measurement solution. Thus, the SPR(Abs) biosensor probe employing the modified Trinder's reagent demonstrated applicability to other analyte biosensing tools.  相似文献   

17.
Carbon nanotube-assisted enhancement of surface plasmon resonance signal   总被引:1,自引:0,他引:1  
We describe a method of amplifying the biosensing signal in surface plasmon resonance (SPR)-based immunoassays using an antibody–carbon nanotube (CNT) conjugate. As a model system, human erythropoietin (EPO) and human granulocyte macrophage colony-stimulating factor (GM–CSF) were detected by sandwich-type immunoassays using an SPR biosensor. For the amplification of the SPR signal, the CNT was conjugated with a polyclonal antibody, and then the conjugates were reacted with antibodies coupled with the target proteins. This amplification strategy increases the dynamic range of the immunoassays and enhances the detection sensitivity. The SPR immunoassays, combined with the CNT-assisted signal amplification method, provided a wide dynamic range over four orders of magnitude for both EPO and GM–CSF (0.1–1000 ng/ml). The CNT amplification method is expected to realize the detection of picogram levels and a wide dynamic detection range of multiple proteins, enabling it to offer a robust analysis tool for the development of biopharmaceutical production.  相似文献   

18.
Peptide-conjugated gold nanorods for nuclear targeting   总被引:2,自引:0,他引:2  
Resonant electron oscillations on the surface of noble metal nanoparticles (Au, Ag, Cu) create the surface plasmon resonance (SPR) that greatly enhances the absorption and Rayleigh (Mie) scattering of light by these particles. By adjusting the size and shape of the particles from spheres to rods, the SPR absorption and scattering can be tuned from the visible to the near-infrared region (NIR) where biologic tissues are relatively transparent. Further, gold nanorods greatly enhance surface Raman scattering of adsorbed molecules. These unique properties make gold nanorods especially attractive as optical sensors for biological and medical applications. In the present work, gold nanorods are covalently conjugated with a nuclear localization signal peptide through a thioalkyl-triazole linker and incubated with an immortalized benign epithelial cell line and an oral cancer cell line. Dark field light SPR scattering images demonstrate that nanorods are located in both the cytoplasm and nucleus of both cell lines. Single cell micro-Raman spectra reveal enhanced Raman bands of the peptide as well as molecules in the cytoplasm and the nucleus. Further, the Raman spectra reveal a difference between benign and cancer cell lines. This work represents an important step toward both imaging and Raman-based intracellular biosensing with covalently linked ligand-nanorod probes.  相似文献   

19.
We propose the combination of surface plasmon resonance (SPR) with living cells as a biosensing method. Our detection scheme is based on the premise that cellular activity induced by external agents is often associated with changes in cellular morphology, which in turn should lead to a variation of the effective refractive index at the interface between the cell membrane and the metal layer. We monitored surface plasmon resonance signals originating from a gold surface coated with cells on a custom apparatus after injection of various agents known to influence cellular activity and morphology. Specifically, we evaluated three types of stimulation: response to an endotoxin (lipopolysaccharides), a chemical toxin (sodium azide) and a physiological agonist (thrombin). A comparison with phase contrast microscopy reveals that SPR signal variations are associated with the induction of cell death for lipopolysaccharides treatment and a contraction of the cell body for sodium azide. Thrombin-induced cellular response shows a rapid decrease of the measured laser reflectance over 5min followed by a return to the original value. For this treatment, phase contrast micrographs relate the first phase of the SPR variation to cell contraction and increase of the intercellular gaps, whereas the recovery phase can be associated with a spreading of the cell on the sensing surface. Hence, the SPR signal is very consistent with the cellular response normally observed for these treatments. This confirms the validity of the biosensing method, which could be applied to a large variety of cellular responses involving shape remodeling induced by external agents.  相似文献   

20.
In clinical practices, the examination of pentamer C-reactive protein (pCRP) is commonly used as a prognostic indicator of the risk of a patient developing cardiovascular disease (CVD). Structural modification of pCRP produces a modified CRP (mCRP) which exhibits different biological activities in the body. In recent years, mCRP has come to be regarded as a more powerful inducer than pCRP, and hence mCRP measurement has emerged as an important indicator for assessing the risk of developing CVD. The surface plasmon resonance (SPR) biosensing technique can be employed to increase the detection accuracy and real-time response when sensing pCRP or mCRP. In this study, three monoclonal antibodies (Mabs), C8, 8D8, and 9C9, are immobilized on a protein G layer for subsequent CRP detection. The experimental results reveal that the Mab C8 reacts with both pCRP and mCRP, the Mab 8D8 with pCRP, and the Mab 9C9 with mCRP. No false signals caused by non-specific binding are observed. When detecting pCRP using Mab C8, the SPR bioassay provides sufficient sensitivity to evaluate whether or not a patient is at risk of developing CVD. SPR biosensing provides a viable and accurate approach for the real-time evaluation of pCRP and mCRP levels, and is therefore of considerable benefit in clinical examinations of CPR.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号