首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The productivity of confirmatory EC broth for the isolation of fecal Escherichia coli was determined at 44.5 and 45.5 C. A variety of frozen pre-cooked foods and an assortment of nutmeats were examined after primary incubation in Lauryl Sulfate Tryptose (LST) broth. In 85.3% of the cases, the parallel tubes of EC broth incubated for 24 hr at 44.5 and 45.5 C gave rise to identical E. coli responses of positive, false positive, and negative. The remaining 14.7% of the reactions represent the qualitative difference between the two temperatures. The EC test at 45.5 C was more specific for E. coli, since two- to threefold fewer false positives were produced at this temperature than at 44.5 C. However, fecal E. coli recoveries were slightly higher (4%) at the lower temperature. Incubating the EC tubes from the interval of 24 to 48 hr gave rise to an additional 4.3% of E. coli recovery, but this was accompanied by an excessive production of false positives (75.9%), representing a 3.5-fold decrease in specificity. It is recommended that, in the confirmatory use of EC broth in the examination of frozen foods and nutmeats for the recovery of fecal E. coli, the test be made at 45.5 C in a water bath and limited to 24 hr of incubation only, to insure optimal specificity. During the study, a “fixed” productivity ratio was noted; E. coli+/LST+ equaled approximately one-fourth or 25%. The significance of this ratio is discussed.  相似文献   

2.
Examination of Market Foods for Coliform Organisms   总被引:4,自引:3,他引:1       下载免费PDF全文
Food specimens (490) in nine categories were examined for total aerobic plate count and numbers and types of coliform organisms, including the enteropathogenic Escherichia coli (EEC). The total counts were compared with various suggested standards, and a limit of 100,000/g appeared to be a realistic goal, except for certain food types with a high level of natural flora. Plate counts in VRB were compared to counts obtained by isolation by enrichment in LST Broth, and the latter method produced a higher percentage of isolations. The presence of E. coli was determined by use of EC Medium incubated at 44.5 +/- 0.1 C. Only 40.4% of the positive EC tubes, however, contained E. coli. It appeared that a limit of 10 coliform organisms per g as a suggested standard could be met with several types of foods. Isolation of EEC was obtained only three times, or in 0.6% of the specimens.  相似文献   

3.
The efficiencies of two 24-hr elevated-temperature tests to recover Escherichia coli from estaurine water were compared simultaneously with the 72-hr standard methods procedure of the American Public Health Association (APHA). From 1,710 tubes, E. coli was recovered 222 times in lauryl tryptose medium incubated at 44 +/- 0.2 C for 24 hr, 261 times in an experimental medium incubated at 44.5 +/- 0.2 C for 24 hr, and 257 times by the 72-hr APHA method. The number of false positives enumerated was similar in all three tests. The data indicated that E. coli in raw seawater could be determined in 24 hr without a significant loss of accuracy.  相似文献   

4.
The current investigation was carried out in order to compare directly the multiple tube fermentation method (MTF), using standard procedures (lactose broth, LB) and the Colilert reagent, with the membrane filter method (MF) using Les Endo agar (LEA), m-faecal coliform agar (mFCA) and chromogenic coliform agar (CCA), for recovery of coliforms and Escherichia coli in 80 surface water samples. Total coliforms were isolated from 100% of samples by all methodologies. Faecal coliforms/E. coli were detected in 100% of samples by MTF methods, but only in 75.5% by MF-mFCA and in 86.2% by MF-CCA. Even if MTF-LB counts were consistently higher, the Colilert reagent accurately determined total coliforms and E. coli levels within 24 h with no additional confirmatory tests. Therefore, it could be a powerful tool for rapidly assessing possible faecal contamination and a suitable alternative to the traditional MTF and MF techniques utilized for coliform detection.  相似文献   

5.
MacConkey (MC), membrane lauryl sulphate (MIS), membrane faecal coliform amended with rosolic acid (MFC + R) and without the acid (MFC - R) were evaluated in the anaerobic membrane filtration (anaerobic-MF) recovery of faecal coliform populations (FCs), genera and faecal coliform positive (FC-positive) strains isolated from various sources of freshwater, i.e., rivers, rural wells, unchlorinated distributive supplies and hand pumps. Mean counts (x 10(2)/100 ml) of presumptive (typical) FCs varied from 13.69 (MC) to 40.81 (MLS) in river samples, and from 2.0 (MC) to 4.19 (MFC + R) in wells. The proportion of FC-positive, typical FCs ranged from 48.66 (MIS) to 66-67% (MC) in rivers, and from 50 (MC) to 90.22% (MFC + R) in wells. More than 30% of the typical FCs from all sources on each medium was FC-negative. These usually formed small (ca 1.0 mm diam.) colonies on the test agar, and were prevalent in wells. Typical FCs and FC-positive strains were not recovered from piped supplies and hand pumps. In spite of anaerobic incubation, non-faecal coliforms (NFCs) were often higher than the FCs; the FC:NFC ratios for rivers ranged from 1.65 (MC) to 7.65 (MLS) and (MFC + R) but were < 1.0 for wells on each medium. Escherichia coli, Klebsiella and Enterobacter species were recovered on all media: approximately 35-64% of the strains confirmed as FCs were E. coli, 20-42% were Kl. pneumoniae. The FC counts on the media were variable, but the overall performance in recovering 'true' FCs was similar; < 70% of strains per medium were FC-positive. None could count E. coli exclusively.  相似文献   

6.
M.T. OGAN. 1992. MacConkey (MC), membrane lauryl sulphate (MIS), membrane faecal coliform amended with rosolic acid (MFC + R) and without the acid (MFC — R) were evaluated in the anaerobic membrane filtration (anaerobic-MF) recovery of faecal coliform populations (FCs), genera and faecal coliform positive (FC-positive) strains isolated from various sources of freshwater, i.e. rivers, rural wells, unchlorinated distributive supplies and hand pumps. Mean counts (x 102/100 ml) of presumptive (typical) FCs varied from 13.69 (MC) to 40.81 (MLS) in river samples, and from 2.0 (MC) to 4.19 (MFC + R) in wells. The proportion of FC-positive, typical FCs ranged from 48.66 (MIS) to 66.67% (MC) in rivers, and from 50 (MC) to 90.22% (MFC + R) in wells. More than 30% of the typical FCs from all sources on each medium was FC-negative. These usually formed small ( ca 1.0 mm diam.) colonies on the test agar, and were prevalent in wells. Typical FCs and FC-positive strains were not recovered from piped supplies and hand pumps. In spite of anaerobic incubation, non-faecal coliforms (NFCs) were often higher than the FCs; the FC: NFC ratios for rivers ranged from 1.65 (MC) to 7.65 (MLS) and (MFC + R) but were < 1.0 for wells on each medium. Escherichia coli, Klebsiella and Enterobacter species were recovered on all media: approximately 35–64% of the strains confirmed as FCs were E. coli, 20–42% were Kl. pneumoniae. The FC counts on the media were variable, but the overall performance in recovering 'true' FCs was similar; < 70% of strains per medium were FC-positive. None could count E. coli exclusively.  相似文献   

7.
An egg yolk-polymyxin medium (KG) for rapid enumeration of Bacillus cereus is described. The test is presumptive in that differentiation of B. cereus (and closely related organisms) from other species is based on the formation of turbidity in the agar surrounding the colonies of the cereus group organisms. The medium is formulated to encourage sporulation and release of free spores for serological confirmatory tests within the 24-hr incubation period. The production of turbidity in egg yolk and free-spore production by 25 strains of B. cereus on KG agar were measured. The recovery of food poisoning strains of B. cereus inoculated into nonsterile food slurries was assessed. A comparison of KG agar and mannitol-egg yolk-polymyxin-agar indicated that the two media were comparable in their abilities to recover low levels of B. cereus from naturally contaminated foods. Since KG agar enhances spore formation by B. cereus, thus permitting early serological testing, its use in screening food products is advocated.  相似文献   

8.
Evidence of the source of carcass contamination of pigs at slaughter was obtained by determining presumptive coliform counts on faeces and on carcass surfaces, and comparing the O-serotypes and antibiotic sensitivity patterns of Escherichia coli from both sites. All of the 16 pig carcasses from the slaughter line of a commercial abattoir were contaminated with presumptive coliform bacilli on most sites examined; the carcasses of six out of eight pigs slaughtered at the Meat Research Institute (MRI) abattoir were also contaminated, but only small numbers of coliforms could be detected on a few of the sites. The proportion of O-serotypes of E. coli present in faeces which were also detected on carcass surfaces, indicating faecal contamination, varied between 0 and 8.6% in MRI slaughtered pigs but reached 66.6% in one group of commercially slaughtered pigs. O-serotypes found on carcass surfaces but not in the faeces of the pigs, were used as an indication of environmental contamination and this was very evident in the commercially slaughtered pigs. A high proportion of E. coli O-serotypes in the gut were resistant to antibiotics and these were also often found on the carcass surface and, since the range of O-serotypes in the pig is similar to that reported in man, the pig must be considered to be a potential reservoir of antibiotic resistant E. coli for man.  相似文献   

9.
Repair and Enumeration of Injured Coliforms in Frozen Foods   总被引:13,自引:6,他引:7       下载免费PDF全文
Two strains of Escherichia coli manifested death and repairable injury after being frozen in water or sterile foods at -20 C. The injured survivors were inhibited from forming colonies on violet red bile agar (VRBA) or deoxycholate lactose agar; this inhibition was greater when enumeration was done by the pour plate method instead of the surface or surface-overlay method. Injured cells repaired rapidly in Trypticase soy broth (TSB), and the repair was about maximum after 1 h at 25 C. When the injured cells were added to different foods and incubated at 25 C, repair also occurred; however, recovery was better and more uniform when the samples were mixed with TSB and incubated 1 h at 25 C. Cell multiplication was not evident until after 90 to 120 min at 25 C. The enumeration of coliforms from commercially frozen foods was increased when the thawed samples were mixed with TSB and the cells were allowed to repair 1 h at 25 C. In some samples, the repair permitted at least a 20-fold increase in the coliform count. The associated flora in the commercially frozen foods gave no evidence of impairing the repair of coliforms, nor did they start multiplication prior to 90 min after being incubated in TSB at 25 C. Generally, the plating gave more reproducible recovery of coliforms than did the most probable number method. Also, a higher number of coliforms were obtained by the surface-overlay method of plating using VRBA.  相似文献   

10.
This study was undertaken to establish and evaluate more rapid methods of estimating Escherichia coli in ground beef than the standard most probable number (MPN) technique. Direct inoculation of and modifications to EC medium gave unreliable estimates of the presumptive E. coli count. Solid media incubated at an elevated temperature were compared to the MPN technique. Anderson and Baird-Parker's tryptone bile agar (TBA) method and prepoured plates of Endo, Levine eosin methylene blue (EMB), and violet red bile (VRBA) agars incubated at 44 degree C gave equivalent counts to the standard MPN method. Anderson and Baird-Parker TBA was the most selective solid medium for E. coli estimation, but all selective media incubated at elevated temperature reduced apparent E. coli counts by as much as 50%. Indole-producing and lactose-fermenting Enterobacteriaceae, capable of growth at elevated temperature, were tested for their growth on TBA, EMB, and VRBA at elevated temperature. TBA was selective for E. coli biotype I compared to other Enterobacteriaceae that predominate in meats. VRBA and EMB incubated at elevated temperature were not as selective as TBA, but differences in colonies could be observed between typical E. coli colonies and other Enterobacteriaceae on these media. Therefore, VRBA incubated at elevated temperature is proposed as a quality assurance screening test for presumptive E. coli in ground meat. Resuscitation techniques and prepoured plates with VRBA increased recovery levels of presumptive E. coli, but, under the conditions of this study, not to levels that represented a significant practical difference.  相似文献   

11.
Estimation of Escherichia coli in raw ground beef.   总被引:2,自引:2,他引:0       下载免费PDF全文
This study was undertaken to establish and evaluate more rapid methods of estimating Escherichia coli in ground beef than the standard most probable number (MPN) technique. Direct inoculation of and modifications to EC medium gave unreliable estimates of the presumptive E. coli count. Solid media incubated at an elevated temperature were compared to the MPN technique. Anderson and Baird-Parker's tryptone bile agar (TBA) method and prepoured plates of Endo, Levine eosin methylene blue (EMB), and violet red bile (VRBA) agars incubated at 44 degree C gave equivalent counts to the standard MPN method. Anderson and Baird-Parker TBA was the most selective solid medium for E. coli estimation, but all selective media incubated at elevated temperature reduced apparent E. coli counts by as much as 50%. Indole-producing and lactose-fermenting Enterobacteriaceae, capable of growth at elevated temperature, were tested for their growth on TBA, EMB, and VRBA at elevated temperature. TBA was selective for E. coli biotype I compared to other Enterobacteriaceae that predominate in meats. VRBA and EMB incubated at elevated temperature were not as selective as TBA, but differences in colonies could be observed between typical E. coli colonies and other Enterobacteriaceae on these media. Therefore, VRBA incubated at elevated temperature is proposed as a quality assurance screening test for presumptive E. coli in ground meat. Resuscitation techniques and prepoured plates with VRBA increased recovery levels of presumptive E. coli, but, under the conditions of this study, not to levels that represented a significant practical difference.  相似文献   

12.
A 1-year study of marine water sample from six beach locations showed that the most-probable-number method failed to recover significant numbers of coli-forms. Modifying this method by transferring, after 48 h, presumptive negatives (growth and no gas production) to confirmed and fecal coliform media significantly improved recovery. Tests which were presumptive negative but confirmed as fecal coliform positive were designated as false negatives. Most-probable-number method false negatives occurred throughout the year, with 143 of 270 samples collected producing false negatives. More than 50% of fecal coliform false-negative isolates were Escherichia coli. Inclusion of false-negative tubes into the coliform most-probable-number method data resulted in increased violation of the California ocean water contact sports standard at all sites. More than 20% of the samples collected were in violation of this standard. These data indicate that modification of the most-probable-number method increases detection of coliform numbers in the marine environment.  相似文献   

13.
The efficiencies of two 24-hr elevated-temperature tests to recover Escherichia coli from estaurine water were compared simultaneously with the 72-hr standard methods procedure of the American Public Health Association (APHA). From 1,710 tubes, E. coli was recovered 222 times in lauryl tryptose medium incubated at 44 ± 0.2 C for 24 hr, 261 times in an experimental medium incubated at 44.5 ± 0.2 C for 24 hr, and 257 times by the 72-hr APHA method. The number of false positives enumerated was similar in all three tests. The data indicated that E. coli in raw seawater could be determined in 24 hr without a significant loss of accuracy.  相似文献   

14.
A 1-year study of marine water sample from six beach locations showed that the most-probable-number method failed to recover significant numbers of coli-forms. Modifying this method by transferring, after 48 h, presumptive negatives (growth and no gas production) to confirmed and fecal coliform media significantly improved recovery. Tests which were presumptive negative but confirmed as fecal coliform positive were designated as false negatives. Most-probable-number method false negatives occurred throughout the year, with 143 of 270 samples collected producing false negatives. More than 50% of fecal coliform false-negative isolates were Escherichia coli. Inclusion of false-negative tubes into the coliform most-probable-number method data resulted in increased violation of the California ocean water contact sports standard at all sites. More than 20% of the samples collected were in violation of this standard. These data indicate that modification of the most-probable-number method increases detection of coliform numbers in the marine environment.  相似文献   

15.
Fluorogenic assays for immediate confirmation of Escherichia coli.   总被引:50,自引:23,他引:27       下载免费PDF全文
Rapid assays for Escherichia coli were developed by using the compound 4-methylumbelliferone glucuronide (MUG), which is hydrolyzed by glucuronidase to yield a fluorogenic product. The production of glucuronidase was limited to strains of E. coli and some Salmonella and Shigella strains in the family Enterobacteriaceae. For immediate confirmation of the presence of E. coli in most-probable-number tubes, MUG was incorporated into lauryl tryptose broth at a final concentration of 100 micrograms/ml. Results of both the presumptive test (gas production) and the confirmed test (fluorescence) for E. coli were obtained from a variety of food, water, and milk samples after incubation for only 24 h at 35 degrees C. Approximately 90% of the tubes showing both gas production and fluorescence contained fecal coliforms (they were positive in EC broth incubated at 45 degrees C). Few false-positive reactions were observed. The lauryl tryptose broth-MUG-most-probable-number assay was superior to violet red bile agar for the detection of heat- and chlorine-injured E. coli cells. Anaerogenic strains produced positive reactions, and small numbers of E. coli could be detected in the presence of large numbers of competing bacteria. The fluorogenic assay was sensitive and rapid; the presence of one viable cell was detected within 20 h. E. coli colonies could be distinguished from other coliforms on membrane filters and plates of violet red bile agar if MUG was incorporated into the culture media. A rapid confirmatory test for E. coli that is amenable to automation was developed by using microtitration plates filled with a nonselective medium containing MUG. Pure or mixed cultures containing E. coli produced fluorescence within 4 h (most strains) to 24 h (a few weakly positive strains).  相似文献   

16.
AIMS: This study examined the suitability of three analytical methods for isolating and enumerating Escherichia coli from conventionally treated sewage sludge. METHODS AND RESULTS: Crude sewage, mesophilic anaerobic digested (MAD) sludge, and final product sludge samples were taken from six sewage treatment works for analysis. Two of the three methods tested were membrane filtration techniques, utilizing chromogenic E. coli/coliform (CEC) media and membrane-lactose glucuronide agar (MLGA); the third method was a most probable number (MPN) technique utilizing Colilert in Quantitray 2000 (Idexx). The methods were evaluated for variation, consistency, false-positive and false-negative results, as well as method correlation. The methods gave good and consistent recovery of E. coli for a range of conventionally treated sewage matrices. All of the methods had a false-positive rate of <3%, although MLGA had a high false-negative rate (35.5%) compared with Colilert (3.81%) and the CEC method (6.75%). This resulted in slightly lower presumptive counts but comparable numbers of confirmed counts. CONCLUSIONS: The three detection methods tested, chromogenic, MLGA and Colilert gave comparable recoveries, and did not vary by greater than one order of magnitude (1 log). SIGNIFICANCE AND IMPACT OF THE STUDY: Forthcoming revisions to the Use of Sludge in Agriculture Regulations (1989) will categorize sewage sludge as untreated, conventionally treated or enhanced treated in accordance to microbiological standards. The standard will be based upon numbers of E. coli removed through the sludge treatment process and the numbers remaining in the final product. It is recommended that the Colilert 2000 (Idexx, Westbrook, Maine) and CEC methods would be equally suitable to assess the reduction of indigenous E. coli in conventionally treated sludges, and that MLGA be used with follow-up confirmatory testing.  相似文献   

17.
A 24-h direct plating method for fecal coliform enumeration with a resuscitation step (preincubation for 2 h at 37 +/- 1 degrees C and transfer to 44 +/- 1 degrees C for 22 h) using fecal coliform agar (FCA) was compared with the 24-h standardized violet red bile lactose agar (VRBL) method. FCA and VRBL have equivalent specificities and sensitivities, except for lactose-positive non-fecal coliforms such as Hafnia alvei, which could form typical colonies on FCA and VRBL. Recovery of cold-stressed Escherichia coli in mashed potatoes on FCA was about 1 log unit lower than that with VRBL. When the FCA method was compared with standard VRBL for enumeration of fecal coliforms, based on counting carried out on 170 different food samples, results were not significantly different (P > 0.05). Based on 203 typical identified colonies selected as found on VRBL and FCA, the latter medium appears to allow the enumeration of more true fecal coliforms and has higher performance in certain ways (specificity, sensitivity, and negative and positive predictive values) than VRBL. Most colonies clearly identified on both media were E. coli and H. alvei, a non-fecal coliform. Therefore, the replacement of fecal coliform enumeration by E. coli enumeration to estimate food sanitary quality should be recommended.  相似文献   

18.
A defined substrate method was applied to drinking water to simultaneously enumerate total coliforms and total Escherichia coli directly from samples. After incubation at 35 degrees C for 24 h, the development of yellow in an initially colorless solution was specific for total coliforms; fluorescence at 366 nm in the same tube(s) or vessel demonstrated the presence of E. coli. No confirmatory or completed steps were necessary. Known as autoanalysis colilert (AC), this method was constituted as a presence-absence test and compared with the methods described in Standard Methods (SM) in the P-A format. Seven water utilities representing a wide geological and hydrological spectrum participated in the evaluation. A total of 702 split drinking water samples were analyzed. Of these, 358 were negative in both tests (SM- and AC-); 302 were positive (SM+ and AC+); and 42 were mixed (SM+ and AC-, 20; AC+ and SM-, 22). The overall agreement rate was 94%. Comparison of the SM and AC results by nonparametric statistics demonstrated no differences. Heterotrophic plate count bacteria exerted no discernible effect on the AC test. By subculture, each time the AC test was yellow, a total coliform was present; when the test was fluorescent, E. coli was isolated.  相似文献   

19.
A defined substrate method was applied to drinking water to simultaneously enumerate total coliforms and total Escherichia coli directly from samples. After incubation at 35 degrees C for 24 h, the development of yellow in an initially colorless solution was specific for total coliforms; fluorescence at 366 nm in the same tube(s) or vessel demonstrated the presence of E. coli. No confirmatory or completed steps were necessary. Known as autoanalysis colilert (AC), this method was constituted as a presence-absence test and compared with the methods described in Standard Methods (SM) in the P-A format. Seven water utilities representing a wide geological and hydrological spectrum participated in the evaluation. A total of 702 split drinking water samples were analyzed. Of these, 358 were negative in both tests (SM- and AC-); 302 were positive (SM+ and AC+); and 42 were mixed (SM+ and AC-, 20; AC+ and SM-, 22). The overall agreement rate was 94%. Comparison of the SM and AC results by nonparametric statistics demonstrated no differences. Heterotrophic plate count bacteria exerted no discernible effect on the AC test. By subculture, each time the AC test was yellow, a total coliform was present; when the test was fluorescent, E. coli was isolated.  相似文献   

20.
A membrane filter-Endo agar method for enumerating Escherichia coli as distinct from other coliforms in drinking water was developed. Membranes containing coliform colonies are transferred to nutrient agar containing 4-methyl umbelliferyl-beta-D-glucuronide (MUG) and incubated at 35 degrees C for 4 h. The MUG is hydrolyzed by the glucuronidase of E. coli and the fluorogenic product is visualized. The method recovered 98% of E. coli without false positives and is proposed as an additional test in routine water examination for the detection of pollution.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号