首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
We developed a real-time electrochemical imaging method that uses a multiple enzyme-modified microelectrode. The method will enable the investigation of the functions of biological materials and cells. To test its effectiveness, we imaged the two-dimensional concentration distribution for hydrogen peroxide and L-glutamate in a standard solution. The multiple electrode consists of an 8 x 8 array of 30 x 30 microm2 carbon micro electrode. Each electrode was connected to a 64-channel potentiostat that could apply a potential to all electrodes at the same time. The multiple electrode was coated with an Os-polyvinylpyridine based polymer (Os-gel) containing horse radish peroxidase (HRP) to detect hydrogen peroxide, which is a very common product of oxidase enzyme. When measuring glutamate, which is a well-known neurotransmitter in the mammalian central nerve system, we modified the electrode with a bilayer of Os-gel-HRP and GluOx. The detection limit of our method was 1 microM and images of the glutamate concentration-distribution changes induced by local injection of glutamate through microcapillary were obtained in real time.  相似文献   

2.
A poly(3-methylthiophene) modified glassy carbon electrode coated with Nafion/single-walled carbon nanotubes film was fabricated and used for highly selective and sensitive determination of dopamine. The hybrid film surface of the modified electrode was characterized by scanning electrochemical microscopy (SECM) and the results indicated that the carbon nanotubes were dispersed uniformly on the conductive polymer. The experimental results suggest that the hybrid film modified electrode combining the advantages of poly(3-methylthiophene), carbon nanotubes with Nafion exhibits dramatic electrocatalytic effect on the oxidation of dopamine (DA) and results in a marked enhancement of the current response. In 0.1M phosphate buffer solution (PBS) of pH 7.0, the differential pulse voltammetric (DPV) peak heights are linear with DA concentration in three intervals, viz. 0.020-0.10 microM, 0.10-1.0 microM and 1.0-6.0 microM, with correlation coefficients of 0.9993, 0.9996 and 0.9993, respectively. The detection limit of 5.0 nM DA could be estimated (S/N=3). Moreover, the interferences of ascorbic acid (AA) and uric acid (UC) are effectively diminished. This hybrid film modified electrode can be applied to the determination of DA contents in dopamine hydrochloride injection and human serum. These attractive features provide a potential application for either in vitro measurement of DA in the presence of excess AA and UA or as detectors in flow injection analysis (FIA) and high performance liquid chromatography (HPLC).  相似文献   

3.
Xiao Y  Guo C  Li CM  Li Y  Zhang J  Xue R  Zhang S 《Analytical biochemistry》2007,371(2):229-237
A new approach was applied to modify gold electrode with a unique polymer composite for selectively detecting dopamine (DA), a neurotransmitter, in the presence of an electroactive species of ascorbic acid (AA). After self-assembly of 11-mercaptoundecanoic acid (MUA) monolayer on gold surface, polyethylene glycol (PEG) was used to perform electrochemical esterification with MUA. In general, AA is the main interference of DA detection in a biological system. The resulting composite layer showed high sensitivity to detect DA but selectively blocked the interference from AA. Furthermore, for the first time, an interesting mechanism was demonstrated from our experimental results, namely, that the catalytic effect of AA on DA is limited by DA concentration when AA/DA>1. The modified electrode showed good reproducibility (+/-2% relative standard deviation), a low detection limit (10 nM), a fast response time (<2s), high sensitivity (86 nA/microM), a wide dynamic range of detection (20 microM), and great selectivity (without AA interference). The discovery is very promising for applications of detection of DA in a physiological environment where a high concentration of AA always exists.  相似文献   

4.
Maturation of primary neuronal cultures is accompanied by an increase in the proportion of cells that exhibit biphasic increase in free cytoplasmic Ca2+ ([Ca2+]i) followed by synchronic decrease in electrical potential difference across the inner mitochondrial membrane (DeltaPsim) in response to stimulation of glutamate receptors. In the present study we have examined whether the appearance of the second phase of [Ca2+]i change can be attributed to arachidonic acid (AA) release in response to the effect of glutamate (Glu) on neurons. Using primary culture of rat cerebellar granule cells we have investigated the effect of AA (1-20 microM) on [Ca2+]i, DeltaPsim, and [ATP] and changes in these parameters induced by neurotoxic concentrations of Glu (100 microM, 10-40 min). At =10 microM, AA caused insignificant decrease in DeltaPsim without any influence on [Ca2+]i. The mitochondrial ATPase inhibitor oligomycin enhanced AA-induced decrease in DeltaPsim; this suggests that AA may inhibit mitochondrial respiration. Addition of AA during the treatment with Glu resulted in more pronounced augmentation of [Ca2+]i and the decrease in DeltaPsim than the changes in these parameters observed during independent action of AA; removal of Glu did not abolish these changes. An inhibitor of the cyclooxygenase and lipoxygenase pathways of AA metabolism, 5,8,11,14-eicosatetraynoic acid, increased the proportion of neurons characterized by Glu-induced biphasic increase in [Ca2+]i and the decrease in DeltaPsim. Palmitic acid (30 microM) did not increase the percentage of neurons exhibiting biphasic response to Glu. Co-administration of AA and Glu caused 2-3 times more pronounced decrease in ATP concentrations than that observed during the independent effect of AA and Glu. The data suggest that AA may influence the functional state of mitochondria, and these changes may promote biphasic [Ca2+]i and DeltaPsim responses of neurons to the neurotoxic effect of Glu.  相似文献   

5.
A glucose detection approach based on the concept of electrochemical depletion of electroactive species in diffusion layer was established, using scanning electrochemical microscopy (SECM). By controlling the glucose oxidase (GOD) modified electrode (substrate electrode) at a proper potential of electrochemical oxidation of interfering electroactive species, i.e., ascorbic acid (AA), an interference-free microcircumstance was formed in the diffusion layer of the substrate electrode. Consequently, we could successfully sense hydrogen peroxide generated from an enzymatic reaction by locating a Pt ultramicroelectrode (UME) (tip electrode, 5 microm in radius) into the diffusion layer of the substrate electrode. Properties of this interference-removing approach based on electrochemical depletion were systematically investigated. Results showed that the interference-removing efficiency was significantly determined by the tip-substrate distance and substrate potential. When the tip-substrate distance was 11 microm (2.2 times of the tip electrode radius) and the substrate potential was 0.5 V, nearly 90% of AA (0.5 mM) could be depleted within 30s without consumption of H2O2. Under these conditions, 0.1 mM AA showed no influence on the detection of 0.5 mM glucose. The linear range of glucose detection is 0.01-1 mM with a detection limit (DL) of 0.005 mM (correlation coefficient is 0.9948). This research will open a new way for developing selective micro-biosensors.  相似文献   

6.
The direct electrocatalytic oxidation of glucose in alkaline medium at nanoscale nickel hydroxide modified carbon ionic liquid electrode (CILE) has been investigated. Enzyme free electro-oxidation of glucose have greatly been enhanced at nanoscale Ni(OH)(2) as a result of electrocatalytic effect of Ni(+2)/Ni(+3) redox couple. The sensitivity to glucose was evaluated as 202 microA mM(-1)cm(-2). From 50 microM to 23 mM of glucose can be selectively measured using platelet-like Ni(OH)(2) nanoscale modified CILE with a detection limit of 6 microM (S/N=3). The nanoscale nickel hydroxide modified electrode is relatively insensitive to electroactive interfering species such as ascorbic acid (AA), and uric acid (UA) which are commonly found in blood samples. Long-term stability, high sensitivity and selectivity as well as good reproducibility and high resistivity towards electrode fouling resulted in an ideal inexpensive amperometric glucose biosensor applicable for complex matrices.  相似文献   

7.
Palladium nanoparticle-loaded carbon nanofibers (Pd/CNFs) were prepared by electrospinning and subsequent thermal treatment processes. Pd/CNFs modified carbon paste electrode (Pd/CNF-CPE) displayed excellent electrochemical catalytic activities towards dopamine (DA), uric acid (UA) and ascorbic acid (AA). The oxidation overpotentials of DA, UA and AA were decreased significantly compared with those obtained at the bare CPE. Differential pulse voltammetry was used for the simultaneous determination of DA, UA and AA in their ternary mixture. The peak separation between UA and DA, DA and AA was 148 mV and 244 mV, respectively. The calibration curves for DA, UA and AA were obtained in the range of 0.5-160 microM, 2-200 microM, and 0.05-4mM, respectively. The lowest detection limits (S/N=3) were 0.2 microM, 0.7 microM and 15 microM for DA, UA and AA, respectively. With good selectively and sensitivity, the present method was applied to the determination of DA in injectable medicine and UA in urine sample.  相似文献   

8.
For simultaneous measurement of glucose, lactate, glutamine, and glutamate a biosensor array is implemented in a micro flow-system thus giving a microsystem. The microsystem consists of a glass chip with the integrated biosensor array and a bottom part, which comprises a gold counter electrode, a 300 microm thick seal, and electrical interconnection lines. The flow device has a total internal volume of 2.1 or 6 microl when integrated with a mixer on chip. The biosensors with no crosstalking and high long term stability were produced by modifying the electrochemical transducers and utilizing photopatternable enzyme membranes. The use of appropriate miniaturization technology leads to mass producable devices for in vivo and ex vivo applications in whole blood and fermentation broth. Due to a novel glutaminase with an activity optimum in the neutral pH range direct and simultaneous monitoring of glutamine together with glucose, lactate, and glutamate could be performed.  相似文献   

9.
An internal standard method has been developed for the determination of the neurotransmitter acetylcholine and/or its metabolic precursor choline. This approach couples the high separation efficiency of capillary electrophoresis with the sensitivity and selectivity of electrochemical detection at an enzyme-modified electrode. Indirect electrochemical detection is accomplished at a 25 microm platinum electrode modified by cross-linking the enzymes choline oxidase and acetylcholinesterase with glutaraldehyde. Although in this simple form of electrode fabrication there is a gradual loss of response from the electrochemical detector with time, accurate quantitation is achieved by the addition of butyrylcholine, which is also a substrate for acetylcholinesterase, as an internal standard. A linear response is achieved between 0 and 125 microM with a limit of detection of 2 microM (25 fmol). The utility of this method was demonstrated by monitoring the kinetics of choline uptake in synaptosomal preparations.  相似文献   

10.
A new type of chemically modified electrode based ring-disk electrode as the dual electrochemical detector (DECD) for high-performance liquid chromatography (HPLC) to simultaneously determine the monoamine neurotransmitters and glucose is described. The ring electrode was modified with an ion-exchange polymer-overoxidized polypyrrole (OPPy) and the disk electrode was modified with nano Au colloid and glucose oxidase (GOD). The electrochemical behaviors of dopamine (DA) and ascorbic acid (AA) at the OPPy chemically modified electrode (CME) were investigated by differential pulse voltammetry (DPV). It was found that the CME could permeate dopamine cations and repelled the ascorbate anions, which could be used to determine the monoamine neurotransmitters and avoid the interference of AA. The electrochemical behavior of glucose at the Nafion/GOD-Au colloid/GC CME was investigated by amperometry and flow injection analysis (FIA). It was found that the sensitivity of the CME increased apparently in determination of glucose. In order to obtain better separation and current responses of the analytes in HPLC-DECD, several operational parameters have been investigated. Under the optimum conditions, the method showed good stability and reproducibility. The application of this method coupled with microdialysis sampling for in vivo simultaneous determination of monoamine neurotransmitters and glucose in rat brain was satisfactory.  相似文献   

11.
Xanthine oxidase (E. C. 1.2.3.2) was immobilized by adsorption on electrochemically modified graphite plate to obtain an enzyme electrode. The current of the enzyme electrode in substrate (xanthine) solutions was found to be a result of the electrooxidation of H2O2 generated in the enzyme layer. The linearity of the amperometric signal was up to a substrate concentration of 65 microM at 0.6 V (vs. Ag/AgCl). The response time was 2 minutes. The enzyme electrode preserves 80% of its initial activity after a three-week storage in air at room temperature.  相似文献   

12.
The use of poly(acrylic acid) (PAA)-multiwalled carbon-nanotubes (MWNTs) composite-coated glassy-carbon disk electrode (GCE) (PAA-MWNTs/GCE) for the simultaneous determination of physiological level dopamine (DA) and uric acid (UA) in the presence of an excess of ascorbic acid (AA) in a pH 7.4 phosphate-buffered solution was proposed. PAA-MWNTs composite was prepared by mixing of MWNTs powder into 1 mg/ml PAA aqueous solution under sonication. GCE surface was modified with PAA-MWNTs film by casting. AA demonstrates no voltammetric peak at PAA-MWNTs/GCE. The PAA-MWNTs composite is of a high surface area and of affinity for DA and UA adsorption. DA exhibits greatly improved electron-transfer rate and is electro-catalyzed at PAA-MWNTs/GCE. Moreover, the electro-catalytic oxidation of UA at PAA-MWNTs/GCE is observed, which makes it possible to detect lower level UA. Therefore, the enhanced electrocatalytic currents for DA and UA were observed. The anodic peak currents at approximately 0.18 V and 0.35 V increase with the increasing concentrations of DA and UA, respectively, which correspond to the voltammetric peaks of DA and UA, respectively. The linear ranges are 40 nM to 3 microM DA and 0.3 microM to 10 microM UA in the presence of 0.3 mM AA. The lowest detection limits (S/N=3) were 20 nM DA and 110 nM UA.  相似文献   

13.
A new set up for multi-analyte sensing: at-line bio-process monitoring   总被引:1,自引:0,他引:1  
A multi-analyte sensing device is described, for simultaneous at-line monitoring of glucose, ethanol, pO?-value and cell density. It consists of a dual biosensor, a modified microscope and a fiber optical pO?-sensor that are integrated into a flow analysis (FA) system. The biosensor is based on a conventional thin layer flow-through cell equipped with a gold (Au) dual electrode (serial configuration). The biosensors with no cross-talking were produced by modifying the electrochemical transducers. Each Au surface was initially modified by self-assembled monolayer (SAM) of cysteamine. Alcohol oxidase (AOx) and pyranose oxidase (PyOx) were immobilized each onto a gold surface by means of PAMAM (polyamidoamine) dendrimer via glutaraldehyde cross-linking. The responses for glucose and ethanol were linear up to 0.5 mM. The operational stability of the biosensors was very promising, after 11 h continuous operation, only 6.0% of the initial activity was lost. The potential of the described biosensor was demonstrated by parallel determination of ethanol and glucose in yeast fermentation process. Simultaneously the cell density of the culture was monitored with an in situ microscope (ISM), which was integrated into the FA system. Both the used in situ microscope and the image processing algorithm used for the analysis of the acquired image data are described. Furthermore the pO?-value was monitored using a fiber optical sensor, which was embedded in a flow cell. The multi-sensor device allows the at-line monitoring of several process values without the need for further sampling or time consuming offline measurements.  相似文献   

14.
A biosensor for glucose using glucose dehydrogenase immobilized on a chemically modified graphite electrode was supplied with coenzyme, nicotinamide adenine dinucleotide (NAD+), through pores in the material. A graphite rod was hollowed out, leaving 0.3 mm at the end contacting the solution, filled with 10 mM NAD+ and pressurized. The response factor was 40% of that obtained when 2 mM NAD+ was mixed with the sample solution in a flow system. The coenzyme consumption was 11 microliters h-1 representing a 500-fold saving compared to supply through the bulk solution. The biosensor had a linear calibration curve from the detection limit, 1 microM, to 2 mM glucose and a repeatability of 0.3%. The graphite electrode was modified by adsorption of a bis-(benzophenoxazinyl)-terephthaloyl derivative in order to be able to oxidize NADH at 0 mV versus Ag/AgCl, 0.1 M KCl.  相似文献   

15.
A simple, selective and sensitive method for the detection of NADH and ethanol is presented. Self-assembled monolayers (SAMs) of mercaptopyrimidine (MPM) and their derivatives, thiocytosine (TC) and 4,6-diamino-2-mercaptopyrimidine (DMP) on gold (Au) electrode are used for the voltammetric detection of NADH and ethanol in neutral aqueous solution. A decrease of 200-300 mV in the overpotential associated with an observable increase in the peak current was obtained for the oxidation of NADH on MPM and TC monolayer-modified electrodes without any redox mediator. The facilitated electron transfer for the oxidation of NADH at the TC monolayer is ascribed to the existence of stable cationic p-quinonoid form of TC. The electrode modified with DMP monolayer could not exhibit stable response for NADH owing to the fouling of electrode surface. The MPM and TC monolayer-modified electrodes show high selectivity and excellent sensitivity (MPM: 0.633+/-0.005 microA cm(-2) microM(-1); TC: 0.658+/-0.008 microA cm(-2) microM(-1)) towards NADH with detection limit (3sigma) of 2.5 and 0.5 microM, respectively. Presence of large excess of ascorbate (AA) does not interfere the detection of NADH and the monolayer-modified electrode shows individual voltammetric peaks for AA and NADH. Voltammetric sensing of ethanol using alcohol dehydrogenase on MPM and TC monolayer-modified electrode is successfully demonstrated and these electrode can detect as low as 0.5 mM ethanol in neutral pH. The sensitivity of the MPM and TC monolayer-modified electrodes toward ethanol was found to be 3.24+/-0.03 and 3.435+/-0.04 microA cm(-2) mM(-1), respectively.  相似文献   

16.
An integrated array of micron-dimension capacitors, originally developed for biometric applications (fingerprint identification), was engineered for detection of biological agents such as proteins and bacteria. This device consists of an array of 93,184 (256 x 364) individual capacitor-based sensing elements located underneath a thin (0.8 microm) layer of glass. This glass layer can be functionalized with organosilane-based monolayers to provide groups amenable for the immobilization of bioreceptors such as antibodies, enzymes, peptides, aptamers, and nucleotides. Upon functionalization with antibodies and in conjunction with signal amplification schemes that result in perturbation of the dielectric constant around the captured antigens, this system can be used as a detector of biological agents. Two signal amplification schemes were tested in this work: one consisted of 4 microm diameter latex immunobeads and a second one was based on colloidal gold catalyzed reduction of silver. These signal amplification approaches were demonstrated and show that this system is capable of specific detection of bacteria (Escherichia coli) and proteins (ovalbumin). The present work shows proof-of-principle demonstration that a simple fingerprint detector based on feedback capacitance measurements can be implemented as a biosensor. The approach presented could be easily expanded to simultaneously test for a large number of analytes and multiple samples given that this device has a large number of detectors. The device and required instrumentation is highly portable and does not require expensive and bulky instrumentation because it relies purely on electronic detection.  相似文献   

17.
An interesting electrochemical sensor has been constructed by the electrodeposition of palladium nanoclusters (Pdnano) on poly(N-methylpyrrole) (PMPy) film-coated platinum (Pt) electrode. Cyclic voltammetry, electrochemical impedance spectroscopy (EIS), and scanning electron microscopy were used to characterize the properties of the modified electrode. It was demonstrated that the electroactivity of the modified electrode depends strongly on the electrosynthesis conditions of the PMPy film and Pdnano. Moreover, the modified electrode exhibits strong electrocatalytic activity toward the oxidation of a mixture of dopamine (DA), ascorbic acid (AA), and uric acid (UA) with obvious reduction of overpotentials. The simultaneous analysis of this mixture at conventional (Pt, gold [Au], and glassy carbon) electrodes usually struggles. However, three well-resolved oxidation peaks for AA, DA, and UA with large peak separations allow this modified electrode to individually or simultaneously analyze AA, DA, and UA by using differential pulse voltammetry (DPV) with good stability, sensitivity, and selectivity. This sensor is also ideal for the simultaneous analysis of AA, UA and either of epinephrine (E), norepinephrine (NE) or l-DOPA. Additionally, the sensor shows strong electrocatalytic activity towards acetaminophen (ACOP) and other organic compounds. The calibration curves for AA, DA, and UA were obtained in the ranges of 0.05 to 1 mM, 0.1 to 10 μM, and 0.5 to 20 μM, respectively. The detection limits (signal/noise [S/N] = 3) were 7 μM, 12 nM, and 27 nM for AA, DA, and UA, respectively. The practical application of the modified electrode was demonstrated by measuring the concentrations of AA, DA, and UA in injection sample, human serum, and human urine samples, respectively, with satisfactory results. The reliability and stability of the modified electrode gave a good possibility for applying the technique to routine analysis of AA, DA, and UA in clinical tests.  相似文献   

18.
A stable electroactive thin film of poly(caffeic acid) has been deposited on the surface of a glassy carbon electrode by potentiostatic technique in an aqueous solution containing caffeic acid. Poly(caffeic acid) was used as a modified electrode for the detection of ascorbic acid (AA), epinephrine (EP), uric acid (UA) and their mixture by cyclic voltammetry. This modified electrode exhibits potent and persistent electron-mediating behavior followed by well-separated oxidation peaks towards AA, EP and UA with activation overpotential. For the ternary mixture containing AA, EP and UA, the three compounds can well separate from each other at the scan rate of 20 mVs(-1) with a potential difference of 156, 132 and 288 mV between AA and EP, EP and UA and AA and UA, respectively, which was large enough to determine AA, EP and UA individually and simultaneously. The catalytic peak current obtained, was linearly dependent on the AA, EP and UA concentrations in the range of 2.0 x 10(-5) to 1.0 x 10(-3) mol l(-1), 2.0 x 10(-6) to 8.0 x 10(-5) mol l(-1) and 5.0 x 10(-6) to 3.0 x 10(-4) mol l(-1), and the detection limits for AA, EP and UA were 7.0 x 10(-6), 2.0 x 10(-7) and 6.0 x 10(-7) mol l(-1), respectively. The modified electrode shows good sensitivity, selectivity and stability, and has been applied to the determination of EP in practical injection samples and that of EP, UA and AA simultaneously with satisfactory results.  相似文献   

19.
We are reporting the selective, sensitive and stable determination of L-cysteine (CY) at physiological pH (pH=7.2) using a gold-aminomercaptothiadiazole core-shell nanoparticles (p-GAMCS NPs) film modified GC electrode. The p-GAMCS NPs film was fabricated on GC electrode by potentiodynamic method using 5-amino-2-mercapto-1,3,4-thiadiazole stabilized gold nanoparticles (AMT-AuNPs). The fabricated p-GAMCS NPs film was characterized by cyclic voltammetry and atomic force microscopy (AFM) techniques. The AFM image of the p-GAMCS NPs film showed that it contains a homogeneously distributed AuNPs with a spherical shape of ~10 nm. The p-GAMCS NPs film modified GC electrode was exploited for the determination of CY. The bare GC electrode failed to show any response for CY (pH=7.2) whereas p-GAMCS NPs film on GC electrode showed a well-defined oxidation peak for CY at 0.51 V. Further, p-GAMCS NPs film modified electrode successfully resolved the voltammetric signals of ascorbic acid (AA) and CY with a peak separation of 500 mV. This is the first report for the large voltammetric peak separation between CY and AA to the best of our knowledge. The amperometric current was increased linearly from 10 nM to 140 nM CY with a detection limit of 3 pM (S/N=3). The present modified electrode showed better recoveries for spiked CY into the human blood serum and urine samples.  相似文献   

20.
We are reporting the selective, sensitive and stable determination of l-cysteine (CY) at physiological pH (pH = 7.2) using a gold–aminomercaptothiadiazole core–shell nanoparticles (p-GAMCS NPs) film modified GC electrode. The p-GAMCS NPs film was fabricated on GC electrode by potentiodynamic method using 5-amino-2-mercapto-1,3,4-thiadiazole stabilized gold nanoparticles (AMT-AuNPs). The fabricated p-GAMCS NPs film was characterized by cyclic voltammetry and atomic force microscopy (AFM) techniques. The AFM image of the p-GAMCS NPs film showed that it contains a homogeneously distributed AuNPs with a spherical shape of ∼10 nm. The p-GAMCS NPs film modified GC electrode was exploited for the determination of CY. The bare GC electrode failed to show any response for CY (pH = 7.2) whereas p-GAMCS NPs film on GC electrode showed a well-defined oxidation peak for CY at 0.51 V. Further, p-GAMCS NPs film modified electrode successfully resolved the voltammetric signals of ascorbic acid (AA) and CY with a peak separation of 500 mV. This is the first report for the large voltammetric peak separation between CY and AA to the best of our knowledge. The amperometric current was increased linearly from 10 nM to 140 nM CY with a detection limit of 3 pM (S/N = 3). The present modified electrode showed better recoveries for spiked CY into the human blood serum and urine samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号