首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 93 毫秒
1.
Three high-performance liquid chromatographic methods are described for the detection of the novel antifolate anticancer drug (6R)-5,10-dideaza-5,6,7,8-tetrahydrofolate (lometrexol): one with fluorometric detection and two with detection by UV absorbance. An assay for plasma lometrexol using UV detection (288 nm) and reversed-phase chromatography was developed, with a quantitation limit of 0.2 μg/ml and linearity up to 10 μg/ml. This assay was modified for measurement of lometrexol in urine, with a quantitation limit of 2 μg/ml and linearity up to 25 μg/ml. An alternative assay for plasma lometrexol using derivatization and fluorescence detection (excitation at 325 nm, emission at 450 nm) was also developed, which proved twenty-fold more sensitive (quantitation limit of 10 ng/ml) than the UV assay, and which was linear up to 250 ng/ml. The fluoremetric method requires sample oxidation with manganese dioxide prior to analysis, and uses ion-pair chromatography with tetramethylammonium hydrogensulphate as an ion-pair reagent. All assays use a similar preliminary solid-phase extraction method (recovery as assessed by UV absorption >73%), with C10-desmethylene lometrexol added for internal standardisation. Each assay is highly reproducible (inter-assay precision in each assay is <10%). Applicability of the fluorescence-based assay to lometrexol in plasma and the UV-based assay lometrexol in urine is demonstrated by pharmacokinetic studies in patients treated as part of a Phase I clinical evaluation of the drug.  相似文献   

2.
A highly sensitive method for the determination of cholesterol in biological fluids is described. Unsaponifiable lipids from rat serum and thoracic duct lymph chylomicron samples were treated with cholesterol oxidase. The product of the enzymatic reaction, Δ4-cholestenone, was analysed by normal-phase high-performance liquid chromatography (HPLC) using hexane—isopropanol (95:5, v/v) as a mobile phase and detected with a UV spectrophotometer at 240 nm. When the standard samples containing varying amounts of cholesterol (0.15–3 nmol) were treated with cholesterol oxidase and analysed by HPLC (injected amounts 0.09–1.8 nmol of cholesterol), the peak areas increased proportionally with the amounts of authentic cholesterol with a correlation coefficient of 0.996. The values in these biological fluids determined by the HPLC method were identical to those obtained by enzymatic—colorimetric or gas chromatographic methods. Moreover, the detection limit (0.09 nmol) of the present method (0.15 nmol are required for the sample preparation) is lower than those of conventional methods (approximately 30 nmol). Because of the excellent sensitivity and reproducibility, this method is well suited for the determination of cholesterol in biological fluids where cholesterol concentration is low.  相似文献   

3.
A rapid and sensitive capillary electrophoretic method for the determination of idarubicin and its metabolite idarubicinol in plasma has been developed and validated. Plasma is extracted by liquid-liquid extraction using chloroform. Idarubicin, idarubicinol and the internal standard daunorubicin can be separated in less than 5 min using a phosphate buffer of pH 5 with 70% acetonitrile. Laser-induced fluorescence detection with an Ar ion laser operated at 488 nm provides a sensitive and selective detection method without interferences from biological fluids. The small sample volume of 100 μl is of particular advantage for studies in pediatric oncology. The reproducibility of the method has been shown to be sufficient for drug monitoring or pharmacokinetic studies. The limit of quantification for idarubicin in plasma is 0.5 ng/ml.  相似文献   

4.
In this paper we develop an high-performance liquid chromatographic method with ultraviolet detection for the determination of verapamil and its primary metabolite norverapamil in biological samples. Both compounds, as well as the internal standard, imipramine, were extracted from alkalinised blood, with n-hexane–isobutyl alcohol, back-extracted into 0.01 M phosphoric acid and determined using a reversed-phase column and ultraviolet monitoring at 210 nm. The average coefficient of variation obtained over the concentration range of 1–1000 ng/ml is about 3%. The detection limit is below 5 ng/ml for both compounds, and extraction recoveries close to 80%. The method was applied to a pharmacokinetic study of the drug and its active metabolite and used to analyse blood samples from verapamil treated rabbits.  相似文献   

5.
A capillary electrophoresis method was developed for the determination of the antibiotic fosfomycin in serum, cerebrospinal fluid and aqueous humor. The technique uses indirect UV detection and the working buffer includes an organic cation to improve fosfomycin mobility. The electrophoretic time of migration is less than 7 min in both fluids. The limit of quantification is 2.5 and 1 μg/ml in serum and aqueous fluids, respectively (signal-to-noise RATIO = 3). The method was validated in serum and water over the concentration range 2.5–200 μg/ml. The calibration graph for serum was linear with a correlation coefficient r = 0.999. At a fosfomycin concentration of 2.5 μg/ml in serum, the intra- and inter-day precisions (coefficients of variation) were 5 and 5.2%, respectively. The mean recovery in serum was 94.5% (S.D. = 2.4%).  相似文献   

6.
A rapid and selective assay of nicotine, cotinine and rans-3'-hydroxycotinine in human serum, based on high-performance liquid chromatography with UV detection has been developed. The compounds were subjected to solid-phase extraction, using Extrelut 1 cartridges. Recoveries were ca. 95% for nicotine, 90% for cotinine and 50–55% for trans-3'-hydroxycotinine. The limit of quantitation observed with this method was 10 ng/ml for nicotine and 5 ng/ml for each of the metabolites. The compounds were also identified using high-performance liquid chromatography with particle beam mass spectrometry, to confirm their presence in human serum.  相似文献   

7.
A new simple and sensitive assay has been developed for the quantitative measurement of BN50730 at the picomole level in human plasma and urine. The drug and the internal standard (BN50765) were measured by combined liquid chromatography—negative chemical ionization mass spectrometry with methane as the reagent gas. A simple solid—liquid extraction procedure was used to isolate BN50730 from complex biological matrices. Mild operating conditions were required to assay the parent drug with a particle beam interface from Hewlett-Packard. The mass spectrometer was tuned to monitor the intense ion m/z 333, which was generated in the ion source by a dissociative capture process. This assay was performed with 1 ml of plasma or 0.1 ml of urine, and the quantification limit of the method was statistically calculated as 1 ng ml−1. The very low relative standard deviation and mean percentage of error calculated during the different within-day or between-day repeatability assays clearly demonstrate the ruggedness of the technique for the routine determination of BN50730 in the biological fluids. Some preliminary results on the pharmacokinetics of the drug are presented to illustrate the applicability of this new powerful LC—MS method.  相似文献   

8.
In doping control laboratories the misuse of anabolic androgenic steroids is commonly investigated in urine by gas chromatography–low-resolution mass spectrometry with selected ion monitoring (GC–LRMS–SIM). By using high-resolution mass spectrometry (HRMS) detection sensitivity is improved due to reduction of biological background. In our study HRMS and LRMS methods were compared to each other. Two different sets were measured both with HRMS and LRMS. In the first set metandienone (I) metabolites 17α-methyl-5β-androstan-3α,17β-diol (II), 17-epimetandienone (III), 17β-methyl-5β-androst-1-ene-3α,17α-diol (IV) and 6β-hydroxymetandienone (V) were spiked in urine extract prepared by solid-phase extraction, hydrolysis with β-glucuronidase from Escherichia coli and liquid–liquid extraction. In the second set the metabolites were first spiked in blank urine samples of four male persons before pretreatment. Concentration range of the spiked metabolites was 0.1–10 ng/ml in both sets. With HRMS (resolution of 5000) detection limits were 2–10 times lower than with LRMS. However, also with the HRMS method the biological background hampered detection and compounds from matrix were coeluted with some metabolites. For this reason the S/N values of the metabolites spiked had to be first compared to S/N values of coeluted matrix compounds to get any idea of detection limits. At trace concentrations selective isolation procedures should be implemented in order to confirm a positive result. The results suggest that metandienone misuse can be detected by HRMS for a prolonged period after stopping the intake of metandienone.  相似文献   

9.
A novel method of high performance liquid chromatography with UV detection for the quantification of caprylic acid in formulations of therapeutic immunoglobulins was developed and validated. Samples have interfering proteins that were removed by ultrafiltration in a centrifugal filter unit of 10 kDa nominal molecular weight limit. Then, compounds present in ultrafiltrates were separated on an Eclipse XDB-C8 5 μm column (150 mm × 4.6 mm i.d.), using a mixture of acetonitrile–water (60:40, v/v) as the mobile phase at a flow rate of 1 mL/min. The UV detection was performed at 210 nm. The method was found to be precise and accurate, with a linearity range from 400 μg/mL to 600 μg/mL (r = 0.9948). The limit of detection (LOD) and the limit of quantification (LOQ) were found to be 13.46 μg/mL and 44.85 μg/mL, respectively. To illustrate the usefulness of the method in the in-process and final quality control for production of therapeutic immunoglobulin formulations, permeates obtained from the industrial diafiltration step in the manufacture of equine-derived snake antivenoms and ten batches of finished product were analyzed.  相似文献   

10.
A high-performance liquid chromatographic method has been developed for the determination of a new cephalosporin antibiotic in plasma, urine and saliva (mixed saliva) using normal-phase technique and an NH2 bonded-phase column. The eluent mixture was a combination of acetonitrile and an aqueous solution of ammonium carbonate. The rapid method involved precipitation of protein from fluids by means of acetonitrile followed by automatic injection of the supernatant. The detection limit was 0.4 μg/ml for plasma, 3 μg/ml for urine and 0.03 μg/ml for saliva using UV detection.  相似文献   

11.
A simple and sensitive high-performance liquid chromatographic (HPLC) method with UV absorbance detection is described for the quantitation of risperidone and its major metabolite 9-hydroxyrisperidone in human plasma, using clozapine as internal standard. After sample alkalinization with 1 ml of NaOH (2 M) the test compounds were extracted from plasma using diisopropyl ether–isoamylalcohol (99:1, v/v). The organic phase was back-extracted with 150 μl potassium phosphate (0.1 M, pH 2.2) and 60 μl of the acid solution was injected into a C18 BDS Hypersil analytical column (3 μm, 100×4.6 mm I.D.). The mobile phase consisted of phosphate buffer (0.05 M, pH 3.7 with 25% H3PO4)–acetonitrile (70:30, v/v), and was delivered at a flow-rate of 1.0 ml/min. The peaks were detected using a UV detector set at 278 nm and the total time for a chromatographic separation was about 4 min. The method was validated for the concentration range 5–100 ng/ml. Mean recoveries were 98.0% for risperidone and 83.5% for 9-hydroxyrisperidone. Intra- and inter-day relative standard deviations were less than 11% for both compounds, while accuracy, expressed as percent error, ranged from 1.6 to 25%. The limit of quantitation was 2 ng/ml for both analytes. The method shows good specificity with respect to commonly prescribed psychotropic drugs, and it has successfully been applied for pharmacokinetic studies and therapeutic drug monitoring.  相似文献   

12.
This review is focused on the different chromatographic strategies for determination of finasteride and its analogues in biological fluids. These compounds are used for the treatment of benign prostatic hyperplasia. Particular attention is paid to high-performance liquid chromatography with spectrophotometric and mass spectrometric detection, the clean-up procedures are also included. The relationships between pharmacokinetics of finasteride, dose administered and required limit of quantitation of the chromatographic assays are discussed. Tandem mass spectrometry is recommended as the detection method for measuring concentrations <1 ng/ml, while cheaper spectrophotometric detection may be selected for determination of higher concentrations.  相似文献   

13.
A sensitive and accurate stable isotope dilution assay was developed for the measurement of pipecolic acid in body fluids using capillary gas chromatography with electron-capture detection. The method utilizes [2H11]pipecolic acid as the internal standard. Sample preparation consisted of derivatization in aqueous solution (pH 11.5) of the amine moiety with methyl chloroformate to the N-methylcarbamate, followed by acidic ethyl acetate extraction at pH ≤ 2 and further derivatization of the carboxyl moiety with pentafluorobenzyl bromide, the excess of which was removed by solid-phase extraction. Control values have been determined in the plasma of at-term infants, age > 1 week (n = 21, mean = 1.36 μM, range = 0.47–3.27 μM). The utility of the method was demonstrated by quantitating pipecolic acid in biological fluids derived from patients with peroxisomal disorders. The method was validated against an established electron-capture negative ion mass fragmentographic technique.  相似文献   

14.
A rapid, inexpensive and sensitive high-performance liquid chromatographic method for the quantitation of ibuprofen enantiomers from a variety of biological fluids is reported. This method uses a commercially available internal standard and has significantly less interference from endogenous co-extracted solutes than do previously reported methods. The method involves the acid extraction of drug and internal standard [(±)-fenoprofen] from the biological fluid with isooctane—isopropanol (95:5) followed by evaporation and derivatization with enthylchloroformate and R-(+)-α-phenylethylamine. Excellent linearity was observed between the peak-area ratio and enantiomer concentration (r > 0.99) over a concentration range of 0.25–50 μg/ml. This method is suitable for the quantitation of ibuprofen from single-dose pharmacokinetic studies involving either rats or humans.  相似文献   

15.
A procedure based on gas chromatography–tandem mass spectrometry for identification and quantitation of lorazepam in plasma and urine is presented. The analyte was extracted from biological fluids under alkaline conditions using solid-phase extraction with an Extrelut-1 column in the presence of oxazepam-d5 as the internal standard. Both compounds were then converted to their trimethylsilyl derivatives and the reaction products were identified and quantitated by gas chromatography–tandem mass spectrometry using the product ions of the two compounds (m/z 341, 306 and 267 for lorazepam derivative and m/z 346, 309 and 271 for oxazepam-d5 derivative) formed from the parent ions by collision-induced dissociation in the ion trap spectrometer. Limit of quantitation was 0.1 ng/ml. This method was validated for urine and plasma samples of individuals in treatment with the drug.  相似文献   

16.
We review the methods used to measure phytoestrogens (genistein, daidzein, lignans and their derivatives) in foods and biological fluids, and discuss advantages and disadvantages of each. The range of detection limits reported varies widely between individual laboratories, but generally the best reported sensitivity is as follows: immunoassay>HPLC-mass spectrometry=HPLC-multichannel electrochemical detection (coularray)>GC-single ion monitoring-mass spectrometry>HPLC-UV diode array>HPLC-single channel electrochemical detection. The best sensitivity reported so far is 0.002 pmol per assay for daidzein by radioimmunoassay. HPLC with UV diode array detection is the most commonly employed, but is the least sensitive and specific. GC and HPLC coupled with mass spectrometry or electrochemical detection are the most accurate and reproducible methods for a wide variety of analytes. Generally most methods, with the exception of immunoassay, have not been correlated with other methods. Recoveries from extraction methods, limits of detection, nature of compounds analysed and the internal standards used are summarised for more than 90 reports in the literature. From this data, it is clear that an inter-laboratory validation and correlation between a wide range of methods for phytoestrogen analysis is required. One underdeveloped area that requires particular attention is the analysis of plant lignans.  相似文献   

17.
The applicability of LC–MS/MS in precursor ion scan mode for the detection of urinary stanozolol metabolites has been studied. The product ion at m/z 81 has been selected as specific for stanozolol metabolites without a modification in A- or N-rings and the product ions at m/z 97 and 145 for the metabolites hydroxylated in the N-ring and 4-hydroxy-stanozolol metabolites, respectively. Under these conditions, the parent drug and up to 15 metabolites were found in a positive doping test sample. The study of a sample from a chimeric uPA-SCID mouse collected after the administration of stanozolol revealed the presence of 4 additional metabolites. The information obtained from the product ion spectra was used to develop a SRM method for the detection of 19 compounds. This SRM method was applied to several doping positive samples. All the metabolites were detected in both the uPA-SCID mouse sample and positive human samples and were not detected in none of the blank samples tested; confirming the metabolic nature of all the detected compounds. In addition, the application of the SRM method to a single human excretion study revealed that one of the metabolites (4ξ,16ξ-dihydroxy-stanozolol) could be detected in negative ionization mode for a longer period than those commonly used in the screening for stanozolol misuse (3′-hydroxy-stanozolol, 16β-hydroxy-stanozolol and 4β-hydroxy-stanozolol) in doping analysis. The application of the developed approach to several positive doping samples confirmed the usefulness of this metabolite for the screening of stanozolol misuse. Finally, a tentative structure for each detected metabolite has been proposed based on the product ion spectra measured with accurate masses using UPLC–QTOF MS.  相似文献   

18.
New methods of ion interaction reagent (IIR) RP-HPLC are presented for the determination of anti-tuberculosis drugs and their metabolites, singly or in multi-component mixtures, in biological fluids. The following analytes are considered: isoniazid, ethionamide, pyrazinamide, morphazinamide, p-aminosalicylic acid, nicotinic and isonicotinic acids. Aqueous solutions of three different ion interaction reagents are alternatively or comparatively used as the mobile phases, namely: (A) 5.00 mM octylamine at pH 3.00 for o-phosphoric acid, (B) 5.00 mM octylamine at pH 8.00 for o-phosphoric acid, and (C) 5.00 mM 1,6 diaminohexane at pH 6.00 for o-phosphoric acid. The response linearity between peak area and analyte concentration is verified for all the analytes in the concentration range within the determination limits and 2.00 mg/l. Detection limits are always lower than 82 μg/l for standard solutions; in the analysis of samples of rat serum, rat plasma and human serum, the matrix effect is negligible, the detection limits are always lower than 94 μg/l and the average recovery yield is always greater than 96%.  相似文献   

19.
An improved high-performance liquid chromatographic assay for the cytostatic drug mitomycin C in plasma is presented. The principal steps are precipitation of plasma proteins with acetonitrile, lyophilization of the supernatant and reversed-phase chromatography on a Hypersil ODS 5 μm column with 0.01 M NaH2PO4 buffer (pH 6.5)-methanol (70:30, v/v) in isocratic mode. At a flow-rate of 1.3 ml/min a column pressure of 180–220 bar resulted. Porfiromycin served as internal standard. UV detection was performed at 365 nm. Quantitation limit based on a coefficient of variation <10% in intra- and inter-day assay was 5 μg/l mitomycin C, detection limit based on a signal-to-noise ratio of 3 was 1 μg/l. Recovery was 100% and linearity was shown for the whole range of concentration (1–500 μg/l). None of the five drugs used during chemoembolisation interfered with the assay in vitro. The assay meets the requirements for pharmacokinetic studies of mitomycin C in patients as regards sensitivity and ease of use.  相似文献   

20.
We developed a rapid and sensitive method of identifying benzodiazepines and zopiclone in human serum using high-performance thin-layer chromatography (HPTLC). These drugs were developed and separated on plates within 8–11 min and detected by means of UV radiation and colour. Each drug was accurately identified by means of the values of RF × 100 and the spot colour in three systems. The detection limit of the benzodiazepines in serum was 0.1-0.4 μg/ml, except for cloxazolam and haloxazolam. The sensitivity was increased about ten-fold over the conventional method. These results suggested that the HPTLC system is useful for the initial detection and identification of these drugs in emergencies.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号