首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A rapid and specific HPLC method has been developed and validated for simultaneous determination of clobazam, the anticonvulsant agent, and its major metabolite in human plasma. The sample preparation was a liquid-liquid extraction with tuloene yielding almost near 100% recoveries of two compounds. Chromatographic separation was achieved with a Chromolith Performance RP-18e 100 mm x 4.6mm column, using a mixture of a phosphate buffer (pH 3.5; 10mM)-acetonitrile (70:30, v/v), in isocratic mode at 2 ml/min at a detection wave-length of 228 nm. The calibration curves were linear (r(2)>0.998) in the concentration range of 5-450 ng ml(-1). The lower limit of quantification was 5 ng ml(-1) for two compounds studied. The within- and between-day precisions in the measurement of QC samples at four tested concentrations were in the range of 0.89-9.1% and 2.1-10.1% R.S.D., respectively. The developed procedure was applied to assess the pharmacokinetics of clobazam and its major metabolite following administration of a single 10mg oral dose of clobazam to healthy volunteers.  相似文献   

2.
Rapid and simple serologic tests that require only a small amount of blood without the euthanization of animals are valuable for microbial control in colonies of laboratory animals. In this study, we developed a multiplex immunochromatographic assay (ICA) for detection of antibodies to Sendai virus (also known as hemagglutinating virus of Japan), hantavirus, and sialodacryoadenitis virus, which are causative agents of major infectious diseases in rats. For this assay, an ICA strip was placed into a microtube containing 150 µl PBS and either 0.75 µl of rat serum or 1.5 µl of whole blood. Binding antibodies were visualized by using anti-rat IgG antibody-conjugated colloidal gold. Under these conditions, the multiplex ICA simultaneously and specifically detected antibodies to multiple antigens. Positive serum samples for each infectious disease were used to evaluate the sensitivity and specificity of the multiplex ICA. The sensitivities of the multiplex ICA for Sendai virus, hantavirus, and sialodacryoadenitis virus were 100%, 100%, and 81%, respectively. No nonspecific reactions were observed in any of the 52 positive sera against heterologous antigens. In addition, 10 samples of uninfected sera did not show any bands except for the control line. These observations indicate high specificity of the multiplex ICA. Moreover, the multiplex ICA could be applied to diluted blood. These results indicate that the multiplex ICA is appropriate for rapid and simple serological testing of laboratory rats.  相似文献   

3.
The rapid, selective and sensitive liquid chromatographic-ion trap mass spectrometric (LC-MS(n)) method was developed and validated for determination of three major components (isovaleryspiramycins, ISV-SPMs) of a novel macrolide antibiotic bitespiramycin and their major active metabolites (spiramycins, SPMs) in rat plasma. The analytes ISV-SPMs, SPMs, internal standard roxithromycin and azithromycin were extracted from plasma samples by liquid-liquid extraction, and chromatographed on a C(18) column using two mobile phase systems. Detection was carried out on an ion trap mass spectrometer by selected reaction monitoring (SRM) mode via electrospray ionization (ESI). Three components (ISV-SPM I, II, III or SPM I, II, III) could be simultaneously determined within 6.5 min. Linear calibration curves were obtained in the concentration ranges of 4-200 ng/ml for ISV-SPM I and SPM I, 12-600 ng/ml for ISV-SPM II and SPM II, and 18-900 ng/ml for ISV-SPM III and SPM III. The intra- and inter-run precision (RSD), calculated from quality control (QC) samples were less than 8.8 and 10.4% for ISV-SPMs, and 9.3 and 11.2% for SPMs, respectively. The method was applied for the evaluation of the pharmacokinetics of bitespiramycin in rats following peroral/intravenous administration.  相似文献   

4.
A new method was developed and validated for quantitating OSI-774 and its metabolite OSI-420 in human plasma. Sample preparation involved initial extraction with methyl t-butyl ether followed by back extraction with HCl and re-extraction with methyl t-butyl ether. This extraction process resulted in significant improvement in the specificity, reproducibility and sensitivity. The analytes were separated on a Water Symmetry C18 analytical column and the mobile phase consisted of acetonitrile-0.05 M potassium phosphate buffer (42:58, v/v) (pH 4.8), and monitored at a wavelength 345 nm. Values of between- and within-day precision and accuracy for both OSI-774 and OSI-420 were <20%. This method was successfully applied to study steady-state pharmacokinetics of OSI-774 and OSI-420 in a phase II clinical trial.  相似文献   

5.
A rapid, selective and sensitive HPLC–tandem mass spectrometry method was developed and validated for simultaneous determination of flupirtine and its active metabolite D-13223 in human plasma. The analytes and internal standard diphenhydramine were extracted from plasma samples by liquid–liquid extraction, and chromatographed on a C18 column. The mobile phase consisted of acetonitrile–water–formic acid (60:40:1, v/v/v), at a flow rate of 0.5 ml/min. Detection was performed on a triple quadrupole tandem mass spectrometer by selected reaction monitoring (SRM) mode via atmospheric pressure chemical ionization (APCI). The method has a limit of quantitation of 10 ng/ml for flupirtine and 2 ng/ml for D-13223, using 0.5-ml plasma sample. The linear calibration curves were obtained in the concentration range of 10.0–1500.0 ng/ml for flupirtine and 2.0–300.0 ng/ml for D-13223. The intra- and inter-run precision (RSD), calculated from quality control (QC) samples was less than 7.2% for flupirtine and D-13223. The accuracy as determined from QC samples was less than 5% for the analytes. The overall extraction recoveries of flupirtine and D-13223 were determined to be about 66% and 78% on average, respectively. The method was applied for the evaluation of the pharmacokinetics of flupirtine and active metabolite D-13223 in volunteers following peroral administration.  相似文献   

6.
A simple HPLC method with photodiode-array (PDA) ultraviolet detection was developed for the simultaneous determination of four active polyphenol components of hawthorn (Crataegus), chlorogenic acid, epicatechin, hyperoside and isoquercitrin, in rat plasma. Following extraction from the plasma samples with ethyl acetate–methanol (2:1, v/v), these four compounds were successfully separated using a C18 column with a gradient elution of 5 and 25% acetonitrile in 25 mM phosphate buffer (pH 2.4). The flow-rate was set at 1 ml/min and the eluent was detected at 325 nm for chlorogenic acid, 278 nm for epicatechin, and 360 nm for both hyperoside and isoquercitrin. Narignin (0.82 μg) was used as the internal standard and was detected at 278 nm. The method is linear over the studied range of 0.16–40, 0.63–160, 0.13–32 and 0.13–30 μg/ml for chlorogenic acid, epicatechin, hyperoside and isoquercitrin, respectively. The correlation coefficient for each analyte was greater than 0.995. The intra-day and inter-day precision of the analysis was better than 4 and 7%, respectively. The extraction recoveries at low to high concentration were greater than 85% for both epicatechin and chlorogenic acid, and greater than 94% for both hyperoside and isoquercitrin. The detection limits were 0.04, 0.20, 0.03 and 0.03 μg/ml for chlorogenic acid, epicatechin, hyperoside and isoquercitrin. The developed method was used to analyze the plasma concentrations of the four analytes after the intravenous administration of hawthorn polyphenol extract to rats.  相似文献   

7.
A simple, precise and accurate high-performance liquid chromatography (HPLC) method using ultraviolet (UV) detection has been developed for simultaneous determination of carbapenem antibiotics: imipenem, meropenem and ertapenem in human plasma. Samples were spiked with ceftazidime as internal standard and proteins were precipitated by acetonitrile. Separation was achieved on a C8 column with a mobile phase composed of phosphate buffer 0.1M (pH 6.8) and methanol in gradient elution mode. Detection was performed at 298 nm. Calibration curves were linear from 0.5 to 80 mg/L for each compound, with correlation coefficients over 0.997. Intra- and inter-day validation studies showed accuracy between -4.5 and 8.1% and precision below 10.4%. Mean recoveries were 82.2, 90.8 and 87.7% for imipenem, meropenem and ertapenem, respectively. This method provides a useful tool for the therapeutic drug monitoring of carbapenems.  相似文献   

8.
A HPLC method with on-line solid phase extraction (SPE) and DAD detection was developed for the simultaneous determination of nitrendipine and hydrochlorothiazide in spontaneously hypertensive rat (SHR) plasma. Plasma samples (100 μL) were injected directly onto a CAPCELL MF C(8) SPE column. High-abundance proteins and most matrixes in plasma were removed by on-line SPE technology, while nitrendipine and hydrochlorothiazide trapped on the SPE column were effectively separated on a C(18) analytical column. The column temperature was maintained at 20°C. The optimal detection wavelength was 237 nm for NTDP and 271 nm for HCTZ. The total analytical run time was 34 min. The proposed method was linear over the range 5-500 ng mL(-1) for nitrendipine and 10-1000 ng mL(-1) for hydrochlorothiazide. The lower limit of detection (LLOD) was 0.5 and 0.6 ng mL(-1) for nitrendipine and hydrochlorothiazide, respectively. The sensitivity and precision of the method were within acceptable limits during validation period. The method was successfully used to investigate the pharmacokinetic characteristics of nitrendipine and hydrochlorothiazide in spontaneously hypertensive rats.  相似文献   

9.
To study the pharmacokinetics of Chan Su, a sensitive and selective method was developed and validated for the determination of five main bufadienolides (cinobufagin, resibufogenin, bufalin, bufotalin and arenobufagin) in rat plasma. The analytes were extracted by liquid-liquid extraction with ethyl acetate after internal standard (IS, caudatin) spiked. The separation was performed by a ZORBAX SB-C18 column (3.5 microm, 2.1 mmx100 mm) and a C18 guard column (5 microm, 4.0 mmx2.0 mm) with an isocratic mobile phase consisted of acetonitrile-water-formic acid (50:50:0.05, v/v/v) at a flow rate of 0.3 mL/min. The Agilent G6410A triple quadrupole LC/MS system was operated under the multiple reaction monitoring mode (MRM) using the electrospray ionization technique in positive mode. The nominal retention times for cinobufagin, resibufogenin, bufalin, bufotalin, arenobufagin and caudatin were 3.07, 3.55, 2.30, 1.62, 1.22 and 3.43 min, respectively. All analytes showed good linearity in a wide concentration range (r>0.995) and their lower limits of quantification (LLOQ) were all 1.0 ng/mL. The method was linear for all analytes with correlation coefficients>0.995 for all analytes. The average extract recoveries of the five analytes from rat plasma were all over 85%, the precisions and accuracies determined were all within 15%. This method has been successfully applied to pharmacokinetic study of Chan Su in rats following oral administration.  相似文献   

10.
A simple method for the quantification of tipranavir, the first non-peptidic HIV protease inhibitor, was developed and validated. Quinoxaline, as internal standard, was added to 50 microl of plasma before a liquid-liquid extraction by 600 microl of protein precipitation solution. The extracts were diluted before being injected in the chromatographic system. Chromatographic separation was made on a C18 column using potassium phosphate buffer (pH 3.2) and acetonitrile with gradient. Detection was performed by an UV detector at 260 nm. Relative error at three control quality concentrations ranged from -1.81 to 1.72%. Intra-day (CV%) and inter-day (CV%) precision ranged from 0.94 to 2.55% and from 3.07 to 4.24%, respectively. LOQ and LOD were 0.090 microg/ml and 0.035 microg/ml, respectively. Mean recovery was 87.1%+/-2.4%. Calibration curve was linear up to 180 microg/ml. Concentration range when optimized (0.703-180 microg/ml) proved to be adequate to measure tipranavir concentration in HIV-1-positive patients, therefore this method could be suitable for therapeutic drug monitoring of this drug.  相似文献   

11.
A sensitive, specific and selective method has been developed for the simultaneous determination of bisoprolol and hydrochlorothiazide in human plasma. The method employed a state of the art LC–MS/MS operated in the positive and negative ionization switching modes. A simple sample preparation step involving protein precipitation with acetonitrile has been optimized; the analytes and the internal standard moxifloxacin were separated on a Purosphere® STAR C8 column (125 mm × 4 mm, 5 μm). The mobile phase was an ammonium acetate solution (1 mM) with formic acid (0.2%): methanol and acetonitrile (65:17.5:17.5, v/v/v (%)), the flow rate was set at 0.65 mL/min. Bisoprolol and hydrochlorothiazide were ionized using ESI source prior to detection by Multiple Reaction Monitoring (MRM) mode while monitoring at the following transitions: positive m/z 326  116 for bisoprolol, negative m/z 296  269 and m/z 296  205 for hydrochlorothiazide. Linearity was demonstrated over the concentration range 0.10–30.0 (ng/mL) for bisoprolol and 1.00–80.00 ng/mL for hydrochlorothiazide. The limits of detection were 0.100 (ng/mL) for bisoprolol and 1.00 (ng/mL) for hydrochlorothiazide. The validated method was successfully applied to a pharmacokinetic study of 5 mg bisoprolol fumarate with 12.5 mg hydrochlorothiazide tablet in healthy volunteers.  相似文献   

12.
A simple and reliable high-performance liquid chromatographic method with ultraviolet detection (280 nm) has been developed for the simultaneous analysis of 12 bioactive components in San-huang-xie-xin-tang (SHXXT), a traditional Chinese medicine containing Rhei rhizome, Coptidis rhizome and Scutellariae radix. A relatively simple extraction procedure was employed and optimised, and separation of the components was obtained within 1 h using a reversed-phase column under gradient elution with acetonitrile and a buffer containing 0.01 M sodium 1-pentanesulphonate (pH 3). The lower limit of detection for the analytes ranged from 25 to 75 ng/mL. The correlation coefficients associated with each calibration curve were greater than 0.99. The precision and accuracy of the method ranged from 1.0 to 10.5% at low concentration levels, 0.8 to 8.7% at medium levels and 1.2 to 5.8% at high levels. In commercial products of SHXXT, baicalin and berberine were present in the highest amounts with levels up to 4.0 and 3.3%, respectively, in one sample. The HPLC method was able rapidly and efficiently to analyse constituents in crude herb and traditional Chinese medicinal preparations containing Rhei rhizome, Coptidis rhizome and Scutellariae radix.  相似文献   

13.
建立HPLC同时测定伤科黄水中6个生物碱的方法。采用XBridge C18色谱柱(3. 5μm,2. 1 mm×100 mm),柱温35℃,测定波长280 nm,以0. 1%磷酸溶液(每100 mL加0. 3 g十二烷基苯磺酸钠)(A)-乙腈-水-磷酸-十二烷基苯磺酸钠(90∶10∶0. 1∶0. 3)(B)为流动相,进行梯度洗脱(0~30 min,B%:35~70; 30~31 min,B%:70~35; 31~40min,B%:35)。经方法学验证,黄柏碱、药根碱、表小檗碱、黄连碱、巴马汀、小檗碱等共6个生物碱分离情况良好,在测定时间段内无明显干扰峰;加样回收率均在95%~115%之间,RSD%均小于5%;精密度RSD%均小于5%;在测定浓度范围内(1~50μg/mL)线性关系良好,相关系数(R^2)大于0. 999。3个不同批次供试品的测定结果较一致。本研究建立的HPLC分析方法可用于同时测定伤科黄水中6个生物碱的含量。  相似文献   

14.
A sensitive, specific and precise HPLC–UV assay was developed to quantitate cocaine (COC) and its metabolites benzoylecgonine (BE), norcocaine (NC) and cocaethylene (CE) in rat plasma. After adding 50 μl of the internal standard solution (bupivacaine, 8 μg/ml) and 500 μl of Sørensen's buffer (pH 6) to 100 μl of rat plasma sample, the mixture was extracted with 10 ml of chloroform. The organic layer was transferred to a clean test tube and was evaporated under nitrogen. The residue was reconstituted in 100 μl of mobile phase and 35 μl was injected onto the HPLC column. The mobile phase consisted of methanol–acetonitrile–50 mM monobasic ammonium phosphate (5:7:63, v/v/v) and was maintained at a flow-rate of 0.4 ml/min. Separation of COC and its metabolites was achieved using a Supelcosil ABZ+plus deactivated reversed-phase column (250×2.1 mm I.D., 5 μm). Calibration curves were linear over the range of 25–5000 ng/ml for COC and its three metabolites. The absolute extraction efficiencies for BE, COC, NC, CE and bupivacaine were 56.6%, 78.6%, 61.1%, 76.4% and 67.0%, respectively. COC and its metabolites were stable in mobile phase for 24 h at room temperature and in rat plasma for 2 weeks at −20°C. The limits of detection for BE, COC, NC and CE were 20, 24, 15 and 12.9 ng/ml, respectively. These values correspond to 0.70, 0.84, 0.525 and 0.452 ng of the according compound being injected on column. The within-day coefficient of variation for the four compounds ranged from 3.0% to 9.9% while the between-day precision varied from 3.6% to 14%. This method was used to analyze rat plasma samples after administration of COC alone and in combination with alcohol. The pharmacokinetic profiles of COC and its metabolites in these rats are also described.  相似文献   

15.
Tanshinone IIA (TS) and cryptotanshinone (CT) are the major active constituents contained in Radix salvia miltiorrhiza. This paper described a rapid, sensitive and specific assay for the simultaneous quantitative determination of TS and CT in rat plasma. After a single step of liquid-liquid extraction, plasma samples were analyzed by high performance liquid chromatography-electrospray ionization-mass spectrometry (HPLC-ESI-MS) using a reversed-phase C18 column (150 mmx2.0 mm, 5 microm, Shim-pack VP-ODS column). The assay was linear in the concentration range of 2-200 ng/ml. The lower limits of quantification of TS and CT were 1 and 0.2 ng/ml, respectively. Recoveries of TS and CT were greater than 80%. The precisions and accuracies determined from 5 days were all within 12%. The assay was applied to a pharmacokinetic study in rats after an oral administration of total tanshinones with a dose of 150 mg/kg (containing 12% of TS and CT). Results showed that this simple and rapid method was sensitive enough to follow the plasma levels of TS and CT in rats, even though the concentration maximums of both were below 20 ng/ml after an oral administration of total tanshinones.  相似文献   

16.
目的:建立同时测定大鼠血浆中阿霉素和塞来昔布的液相色谱-串联质谱(LC/MS/MS)方法,研究这两种药物联合应用的药代动力学.方法:大鼠尾静脉注射阿霉素和塞来昔布,眼眶取血并抗凝,离心分离血浆,采用乙酸乙酯提取血浆中的阿霉素和塞来昔布,N2吹干乙酸乙酯,残留物用50μL甲醇溶解,取20μL用于LC/MS/MS分析.结果:用LC/MS/MS法检测大鼠血浆中阿霉素和塞来昔布的线性范围为1-800ng/mL,日内、日间精密度(RSD)均小于15%,检测血浆低、中、高三个浓度(8、50、500ng/mL)阿霉素的回收率分别为101.2%、95.1%和91.4%,检测血浆低、中、高三个浓度(8、50、500ng/mL)塞来昔布的回收率分别为105.6%、106.8%和93.7%.大鼠尾静脉注射5.8mg/kg阿霉素和3.8mg/kg塞来昔布的半衰期分别为2.3 h和3.6h,曲线下面积分别为670 ng·h·mL-1和1480ng·h·mL-1.结论:建立的方法灵敏、准确、快速,适甩于阿霉素和塞来昔布的药代动力学研究.  相似文献   

17.
This paper describes a sensitive and specific enzymatic-radioisotopic method for determining plasma choline. Assays may be performed without prior extraction of the tissue. Plasma is first heated to destroy enzymes that would otherwise produce free choline from that which is normally bound. The free choline in plasma is then converted to phosphorylcholine [32P], in the presence of ATP-γ-32P, in a reaction catalyzed by choline kinase. Phosphorylcholine [32P], isolated by ion-exchange chromatography, is measured as an index of the concentration of free choline. The concentration of plasma choline in man and in several species of laboratory animals was determined, and found to range from 5.5 nmoles/ml in dogs to 15.4 nmoles/ml in guinea pigs. The concentration of free choline in plasma of adult rats raised on a choline-deficient diet was half that of littermate controls raised on a control diet supplemented with free choline.  相似文献   

18.
A sensitive and reliable high-performance liquid chromatographic (HPLC) assay is a prerequisite for pharmacokinetic analysis of continuous infusion of levomepromazine adjuvant to midazolam. We developed such a method to determine the levels of levomepromazine, midazolam and their major metabolites (levomepromazinesulfoxide, desmethyl-, didesmethyllevomepromazine, O-desmethyllevomepromazine and alpha-hydroxy-midazolam) simultaneously. Desmethylclomipramine was used as an internal standard (I.S.). The lower limit of quantification of this assay was set for levomepromazine 4.1 microg/l, levomepromazinesulfoxide 4.9 microg/l, O-desmethyllevomepromazine 18.4 microg/l, alpha-hydroxymidazolam 26.6 microg/l, midazolam 23.4 microg/l, didesmethyllevomepromazine 15.8 microg/l, and desmethyllevomepromazine 6.6 microg/l. The between- and within day assay variations were commonly below 5%. The recovery in human plasma for the different analytes varied between 85 and 11%. The accuracy of this assay varied between 95 and 105% for the different concentrations. The linearity of this assay was set between 25 and 800 microg/l (r(2)>0.999 of the regression line). The first results of pharmacokinetic analysis of midazolam indicated that half-life varied between 1.1 and 1.9 h. Pharmacokinetic analysis using a one-compartment model of levomepromazine revealed that the apparent volume of distribution was 4.1+/-2.4 l per kg lean body mass and the metabolic clearance was 309+/-225 l per hour per 70 kg. This assay proved to be robust and reproducible. It can reliably be used for further study of the pharmacokinetics of continuous infusion of levomepromazine.  相似文献   

19.
Pentosidine is an advanced glycation end-product (AGE) appearing when arginine and lysine residues in proteins are cross-linked with carbonyl derivatives. This paper presents an improved method for the synthesis of pentosidine and reversed-phase chromatography of this substance with fluorometric detection that enables sensitive (0.01 pmol/mg protein) and specific determination of pentosidine in plasma. Separation is done twice on the same C(18) Vydac 218TP54 column, first with trifluoroacetic acid and next with heptafluorobutyric acid as ion pair. The inter-day coefficient of variation is 6.4% at pentosidine concentration in plasma of 25 pmol/mg protein and 8% at 1.7 pmol/mg protein. Spectral properties of pentosidine exploited during identification of the substance with UV absorption and fluorescence detectors are described. Maximum of absorbance was observed at 325 nm, maximum fluorescence at lambda(ex)/lambda(em)=330/373 nm. The method may prove useful for the study of processes associated with generation and accumulation of pentosidine in the body as a marker of AGE production in healthy subjects and patients with chronic renal failure.  相似文献   

20.
A new method of amperometric determination of phenolic compounds using an enzyme electrode is proposed. The latter represents the combination of the oxygen electrode and immobilized laccase. Analytical systems of flow injection and batch types were considered. A method of immobilization was developed that provided an increase in the stability of the enzyme. Optimal conditions for biosensor operation were found. The time needed for analysis in the flow injection mode was below 100 s. A column with immobilized enzyme could be used for up to 500 determinations of phenolic compounds without decrease of the enzyme activity. The practical validity of the method was demonstrated by tannin analysis in tea of different brands.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号