1.
A new functional fluorinated material taking n‐propyltrimethoxysilicane (n‐propyl‐TriMOS) and 3,3,3‐trifluoropropyltrimethoxysilicane (TFP‐TriMOS) as precursors was applied to construct a novel dissolved oxygen sensing film. The sensing film was fabricated by dip‐coating the functional fluorinated material‐doped [meso‐tetrakis(pentafluorophenyl) porphyinato] platinum(II) (PtF20TPP) onto a glass slide. The oxygen sensing film exhibited a good linear relationship, fast response time, long stability and high sensitivity to dissolved oxygen. In the developed optical oxygen sensor, an LED and a photodiode were composed to construct a back‐detection optical system not needing an optical fiber based on fluorescence intensity detection. The smart optical oxygen sensor based on the PtF20TPP fluorescence quenching possesses the advantages of portability and low cost and can be applied to the dissolved oxygen in situ monitoring in seawater. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

2.
Non-invasive, simultaneous optical monitoring of oxygen and pH during bacterial cultivation in 24-well microplates is presented using an integrated dual sensor for dissolved oxygen and pH values. The dual sensor is based on oxygen-sensitive organosilica microparticles and pH-sensitive microbeads from a polymethacrylate derivative embedded into a polyurethane hydrogel. The readout is based on a phase-domain fluorescence lifetime-based method referred to as modified frequency domain dual lifetime referencing using a commercially available detector system for 24-well microplates. The sensor was used for monitoring the growth of Pseudomonas putida bacterial cultures. The method is suitable for parallelized, miniaturized bioprocessing, and cell-based high-throughput screening applications.  相似文献   

3.

Background  

Dissolved oxygen tension (DOT) is an important parameter for evaluating a bioprocess. Conventional means to measure DOT in shake flasks using fixed Clark-type electrodes immersed in the bulk liquid are problematic, because they inherently alter the hydrodynamics of the systems. Other approaches to measure DOT that apply fluorescing sensor spots fixed at the inside wall of a shake flask are also suboptimal. At low filling volumes for cultivating microorganisms with a high oxygen demand, the measured DOT signal may be erroneous. Here, the sensor spot is sometimes exposed to gas in the head space of the flask. Merely repositioning the sensor spot elsewhere in the flask does not address this problem, since there is no location in the shake flask that is always covered by the rotating bulk liquid. Thus, the aim of this prospective study is first, to verify the systemic error of Clark-type electrodes for measuring DOT in shake flasks. The second principle aim is to use the newly built "flexitube optical sensor" to verify potential errors in conventional optical DOT measurements based on fixed sensor spots.  相似文献   

4.
Membrane-aerated microbioreactor for high-throughput bioprocessing   总被引:2,自引:0,他引:2  
A microbioreactor with a volume of microliters is fabricated out of poly(dimethylsiloxane) (PDMS) and glass. Aeration of microbial cultures is through a gas-permeable PDMS membrane. Sensors are integrated for on-line measurement of optical density (OD), dissolved oxygen (DO), and pH. All three parameter measurements are based on optical methods. Optical density is monitored via transmittance measurements through the well of the microbioreactor while dissolved oxygen and pH are measured using fluorescence lifetime-based sensors incorporated into the body of the microbioreactor. Bacterial fermentations carried out in the microbioreactor under well-defined conditions are compared to results obtained in a 500-mL bench-scale bioreactor. It is shown that the behavior of the bacteria in the microbioreactor is similar to that in the larger bioreactor. This similarity includes growth kinetics, dissolved oxygen profile within the vessel over time, pH profile over time, final number of cells, and cell morphology. Results from off-line analysis of the medium to examine organic acid production and substrate utilization are presented. By changing the gaseous environmental conditions, it is demonstrated that oxygen levels within the microbioreactor can be manipulated. Furthermore, it is demonstrated that the sensitivity and reproducibility of the microbioreactor system are such that statistically significant differences in the time evolution of the OD, DO, and pH can be used to distinguish between different physiological states. Finally, modeling of the transient oxygen transfer within the microbioreactor based on observed and predicted growth kinetics is used to quantitatively characterize oxygen depletion in the system.  相似文献   

5.
Oxygen plays a key role in stem cell biology as a signaling molecule and as an indicator of cell energy metabolism. Quantification of cellular oxygen kinetics, i.e. the determination of specific oxygen uptake rates (sOURs), is routinely used to understand metabolic shifts. However current methods to determine sOUR in adherent cell cultures rely on cell sampling, which impacts on cellular phenotype. We present real‐time monitoring of cell growth from phase contrast microscopy images, and of respiration using optical sensors for dissolved oxygen. Time‐course data for bulk and peri‐cellular oxygen concentrations obtained for Chinese hamster ovary (CHO) and mouse embryonic stem cell (mESCs) cultures successfully demonstrated this non‐invasive and label‐free approach. Additionally, we confirmed non‐invasive detection of cellular responses to rapidly changing culture conditions by exposing the cells to mitochondrial inhibiting and uncoupling agents. For the CHO and mESCs, sOUR values between 8 and 60 amol cell?1 s?1, and 5 and 35 amol cell?1 s?1 were obtained, respectively. These values compare favorably with literature data. The capability to monitor oxygen tensions, cell growth, and sOUR, of adherent stem cell cultures, non‐invasively and in real time, will be of significant benefit for future studies in stem cell biology and stem cell‐based therapies.  相似文献   

6.
Microtiter plates with integrated optical sensing of dissolved oxygen were developed by immobilization of two fluorophores at the bottom of 96-well polystyrene microtiter plates. The oxygen-sensitive fluorophore responded to dissolved oxygen concentration, whereas the oxygen-insensitive one served as an internal reference. The sensor measured dissolved oxygen accurately in optically well-defined media. Oxygen transfer coefficients, k(L)a, were determined by a dynamic method in a commercial microtiter plate reader with an integrated shaker. For this purpose, the dissolved oxygen was initially depleted by the addition of sodium dithionite and, by oxygen transfer from air, it increased again after complete oxidation of dithionite. k(L)a values in one commercial reader were about 10 to 40 h(-1). k(L)a values were inversely proportional to the filling volume and increased with increasing shaking intensity. Dissolved oxygen was monitored during cultivation of Corynebacterium glutamicum in another reader that allowed much higher shaking intensity. Growth rates determined from optical density measurement were identical to those observed in shaking flasks and in a stirred fermentor. Oxygen uptake rates measured in the stirred fermentor and dissolved oxygen concentrations measured during cultivation in the microtiter plate were used to estimate k(L)a values in a 96-well microtiter plate. The resulting values were about 130 h(-1), which is in the lower range of typical stirred fermentors. The resulting maximum oxygen transfer rate was 26 mM h(-1). Simulations showed that the errors caused by the intermittent measurement method were insignificant under the prevailing conditions.  相似文献   

7.
Optical methods for O2 determination based on dynamic fluorescence quenching have been applied to measure oxygen uptake rates in cell culture and to determine intracellular oxygen levels. Here we demonstrate the applicability of fluorescence-based probes in determining kinetic parameters for O2 using as an example catalysis by a cofactor-independent oxygenase (DpgC). Fluorescence-based sensors provide a direct assessment of enzyme-catalyzed O2 consumption using commercially available, low-cost instrumentation that is easily customizable and, thus, constitutes a convenient alternative to the widely used Clark-type electrode, especially in cases where chemical interference is expected to be problematic.  相似文献   

8.
O2 uptake rates of animal cells (Chinese hamster ovary-CHO) were measured in 96-well microtiter plates by integrating with fluorescent sensors thereby measuring fluorescence intensity ratios of an O2-sensitive and an insensitive fluorophor. O2 consumption rate was estimated from measured dissolved O2 and from O2 mass transfer coefficient determined in advance. Specific uptake decreased with time from 3.2 x 10(-13) mol O2 cell(-1) h(-1) at 15 h cultivation to 1.8 x 10(-13) mol O2 cell(-1) h(-1) at 48 h. Specific O2 uptake was also determined by sampling from a spinner-flask culture giving identical values. A cell viability assay for cultures based on O2 measurements is described in which cells are incubated outside the fluorescence reader and then the dissolved O2 is measured only once at a fixed time after the start of incubation. This protocol can be directly applied for high-throughput measurements.  相似文献   

9.
Biofilm‐related research using 96‐well microtiter plates involves static incubation of plates indiscriminate of environmental conditions, making oxygen availability an important variable which has not been considered to date. By directly measuring dissolved oxygen concentration over time we report here that dissolved oxygen is rapidly consumed in Staphylococcus epidermidis biofilm cultures grown in 96‐well plates irrespective of the oxygen concentration in the gaseous environment in which the plates are incubated. These data indicate that depletion of dissolved oxygen during growth of bacterial biofilm cultures in 96‐well plates may significantly influence biofilm production. Furthermore higher inoculum cell concentrations are associated with more rapid consumption of dissolved oxygen and higher levels of S. epidermidis biofilm production. Our data reveal that oxygen depletion during bacterial growth in 96‐well plates may significantly influence biofilm production and should be considered in the interpretation of experimental data using this biofilm model. Biotechnol. Bioeng. 2009;103: 1042–1047. © 2009 Wiley Periodicals, Inc.  相似文献   

10.
Catalase is one of the major antioxidant enzymes that catalyzes the hydrolysis of H2O2. The aim of this study was to suggest a new method for the assay of catalase activity. For this purpose, an amperometric biosensor based on glucose oxidase for determination of catalase activity was developed. Immobilization of glucose oxidase was made by a cross-linking method with glutaraldehyde on a Clark-type electrode (dissolved oxygen probe). Optimization and characterization properties of the biosensor were studied and determination of catalase activity in defined conditions was investigated in artificial serum solution. The results were compared with a reference method.  相似文献   

11.
We measured the light response curve of photosynthetic oxygen evolution by illuminating a leaf disc in an air-tight windowed chamber. Oxygen production was measured by monitoring the quenching of luminescence of an organometallic ruthenium compound. A photodiode based chlorophyll a fluorometer was used to measure the luminescence intensity. Oxygen evolution measurements with a traditional oxygen electrode gave the same numerical values at different light intensities when the same leaf disk was tested. The quality of the measurement signal of the new method was found to be similar to that obtained with the oxygen electrode method. The new luminescence based system is more stable against electrical disturbances than an oxygen electrode, its response to oxygen pressure changes is very rapid, and the new method allows the same basic equipment to be used for chlorophyll fluorescence and oxygen measurements.  相似文献   

12.
A novel trienzyme sensor for the amperometric determination of lactate was constructed by immobilizing salicylate hydroxylase (SHL, E.C. 1.14.13.1), l-lactate dehydrogenase (LDH, E.C. 1.1.1.27), and pyruvate oxidase (PyOD, E.C. 1.2.3.3) on a Clark-type oxygen electrode. The enzymes were entrapped by a poly(carbamoyl) sulfonate (PCS) hydrogel on a Teflon membrane. LDH catalyzes the specific dehydrogenation of lactate consuming NAD(+). SHL catalyzes the irreversible decarboxylation and the hydroxylation of salicylate in the presence of oxygen and NADH produced by LDH. PyOD decarboxylates pyruvate using oxygen and phosphate. SHL and PyOD force the equilibrium of dehydrogenation of lactate by LDH to the product side by consuming NADH and pyruvate, respectively. Dissolved oxygen acts as an essential material for both PyOD and SHL during their respective enzymatic reactions. Therefore, an amplified signal, caused by the consumptions of dissolved oxygen by the two enzymes, was observed in the measurement of lactate. Regeneration of cofactor was found in the trienzyme system. A Teflon membrane was used to fabricate the sensor in order to avoid interferences. The sensor has a fast response (2s) and short recovery times (2 min). The total test time for a measurement by using this lactate sensor (4 min) was faster than using a commercial lactate testing kit (up to 10 min). The sensor has a linear range between 10 and 400 microM lactate, with a detection limit of 4.3 microM. A good agreement (R2 = 0.9984) with a commercial lactate testing kit was obtained in beverage sample measurements.  相似文献   

13.
The bacterial electrode for amperometric determination of iron ions is based on a Clark-type oxygen electrode, on the measuring part of which a paste containing a mixture of jarosite precipitate and iron-oxidizing bacteria is mounted with the aid of a cellophane membrane. In acidic media a biochemical oxidation of Fe2+ connected with oxygen consumption takes place in the biocatalytic layer. Fe3+ is determined after its reduction to Fe2+. The determination limit is 60 μmol/L, the stability of the electrode is two months at room temperature.  相似文献   

14.
Oxygen consumption rate of tissue measured by a micropolarographic method   总被引:3,自引:3,他引:0  
A new method for measuring the oxygen consumption rate of a sheet of homogeneous tissue is described. The method measures, by a Clark-type oxygen electrode without a membrane, the time for the tissue to consume all its dissolved oxygen. The electrode is applied to one surface of the tissue sheet and the other surface is sealed from the atmosphere by a cover slip. The consumption is calculated from an estimate of the oxygen dissolved in the tissue at the moment it is covered and the time for the oxygen tension at one surface to fall to zero. The data also yield the oxygen diffusion coefficient in the oxygen-consuming tissue.  相似文献   

15.
Oxygen binding of hemocyanins results in an absorption band around 340nm and a strong quenching of the intrinsic tryptophan fluorescence. Our study analyses in detail the fluorescence quenching within two hemocyanins, a hexamer (Panulirus interruptus) and a 4 x 6-mer (Eurypelma californicum). Based on the comparison of calculated and measured transfer efficiencies we could show that: (1) For both hemocyanins FRET (fluorescence resonance energy transfer) is exclusively responsible for quenching of the tryptophan fluorescence upon oxygen binding. (2) Tryptophan quenching by FRET is independent of the oxy- or deoxy conformation of the protein. (3) The quenching takes place at the subunit level only and the oligomerization of both hemocyanins has no influence on the amount of quenching. Therefore, tryptophan fluorescence is a linear sensor for bound oxygen. It can be used as a model-free signal to investigate oxygen binding of hemocyanins at all aggregation levels. Furthermore it may provide a new way to analyse oxygen binding of phenoloxidases.  相似文献   

16.
L F Povirk  I H Goldberg 《Biochemistry》1980,19(21):4773-4780
The methanol-extracted, nonprotein chromophore of neocarzinostatin (NCS), which has DNA-degrading activity comparable to that of the native antibiotic, was found to have a strong affinity for DNA. Binding of chromophore was shown by (1) quenching by DNA of the 440-nm fluorescence and shifting of the emission peak to 420 nm, (2) protection by DNA against spontaneous loss of activity in aqueous solution, and (3) inhibition by DNA of the spontaneous generation of 490-nm fluorescence. Good quantitative correlation was found between these three methods in measuring chromophore binding. There was nearly a 1:1 correspondence between loss of chromophore activity and generation of 490-nm fluorescence, suggesting spontaneous degradation of active chromophore to a highly fluorescent product. Chromophore showed a preference for DNA high in adenine + thymine content in both fluorescence quenching and protection studies. NCS apoprotein, which is known to bind and protect active chromophore, quenched the 440-nm fluorescence, shifted the emission peak to 420 nm, and inhibited the generation of 490-nm fluorescence. Chromophore had a higher affinity for apoprotein than for DNA. Pretreatment of chromophore with 2-mercaptoethanol increased the 440-nm fluorescence seven-fold and eliminated the tendency to generate 490-nm fluorescence. The 440-nm fluorescence of this inactive material was also quenched by DNA and shifted to 420 nm, indicating an affinity for DNA comparable to that of untreated chromophore. However, its affinity for apoprotein was much lower than that of untreated chromophore. Both 2-mercapto-ethanol-treated and untreated chromophore unwound supercoiled pMB9 DNA, suggesting intercalation by both molecules. Since no physical evidence for interaction of native neocarzinostatin with DNA has been found, it is likely that dissociation of the chromophore from the protein and association with DNA are important steps in degradation of DNA by neocarzinostatin.  相似文献   

17.
The presence of low levels of oxygen may have profound effects on the cytotoxic activity of radiation, radiosensitizers, and bioreductive alkylating agents. As others have shown, low oxygen tensions may significantly alter rates of cellular and chemical oxygen consumption. When experiments are performed at very low oxygen concentrations, the opposing effects of oxygen leakage into and cellular/chemical oxygen consumption from the system can lead to unpredictable results. Use of a newly designed, highly sensitive Clark-type oxygen sensor has permitted accurate and reproducible measurement of low levels of oxygen. Cellular depletion of oxygen at various cell densities has been monitored for a series of oxygen tensions in solution and the corresponding respiration rates have been calculated. Although oxygen depletion was found to be quite significant at low oxygen tensions, not all oxygen present could be removed by cellular respiration. Respiration rate decreased as oxygen tension decreased and approached zero at low oxygen tensions. This result was independent of cell density. A model is presented to account for the observed effect of oxygen tension on cellular oxygen utilization.  相似文献   

18.
A simple chlorophyll fluorescence (CF) measuring system has been implemented to study temporal characteristics of chlorophyll fluorescence induction (CFI) in dark-adapted freshwater algal cultures of Chlorella emersonii. There were two different decay time constants describing the CF quenching: τ0 (the faster) and τ1 (the slower) with amplitudes A0 and A1, respectively. The relative amplitude of the faster quenching component decreased once the sample was subject to deprivation from dissolved oxygen (DO). The DO concentration of samples was monitored to validate the effects of deprivation from air contact for up to 7 d and to the effect of adding DCMU to the culture (herbicide for blocking electron transport of photosystem 2). CFI analysis and DO measurements showed that the relative amplitude of A0 to (A0 + A1) and the DO concentration can be used as an indication of relative photosynthetic activity, thus allowing for the possibility to classify the physiological state of algal blooms into active and inactive states.  相似文献   

19.
In vivo, the pH value and oxygen partial pressure are the most important physico-chemical parameters in the microenvironment of human tissues. In vitro, the extracellular acidification rate of cell cultures is an indicator of global cellular metabolism, while the rate of oxygen consumption is a measure of mitochondrial activity. Earlier approaches had the disadvantage that these two values had to be measured with two separate sensors at different loci within the tissue or cell culture. Furthermore, conventional Clark-type oxygen sensors are not very compatible for miniaturisation, making it impossible to measure at small cell volumes or even at the single cell level. We have, therefore, developed an ISFET based sensor structure which is able to measure both pH and oxygen partial pressure. This sensor structure was tested in vitro for simultaneous records of cellular acidification and respiration rates at the same site within the cell culture. This sensor is manufactured by a CMOS-process.  相似文献   

20.
In recent years, in-situ fluorometers have been extensively deployed to monitor cyanobacteria in near real-time. Acceptable accuracy can be achieved between measured pigments and cyanobacteria biovolume provided the cyanobacteria species are known. However, cellular photosynthetic pigment content and measurement interferences are site and species specific and can dramatically affect sensor reliability. We quantified the accuracy of an in-situ fluorometer compared with traditional methods using mono- and mixed cultures of four different cyanobacterial species. We found: (1) lower pigment content in cultures in stationary phase, (2) higher precision with the sensor compared to traditional pigment quantification methods of measuring phycocyanin and chlorophyll a, (3) species-specific relationships between sensor readings and measurements related to biovolume, (4) overestimation of pigments in mixed compared with mono cultures, (5) dissolved organic matter causing a loss in signal proportional to its degree of aromaticity, and (6) potential to quantify the degree of cell lysis with a fluorescent dissolved organic matter sensor. This study has provided important new information on the strengths and limitations of fluorescence sensors. The sensor readings can provide accurate biovolume quantification and species determination for a number of bloom-forming species when sensors are properly compensated and calibrated.  相似文献   