首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Cai H  Zhu N  Jiang Y  He P  Fang Y 《Biosensors & bioelectronics》2003,18(11):1311-1319
Synthesis of the novel Cu@Au alloy nanoparticle and its application in an electrochemical DNA hybridization detection assay is described in this article. We report a low-temperature method for generating core-shell particles consisting of a core of Cu and a thin layer of Au shell that can be readily functionalized with oligonucleotides. Core-shell Cu@Au particles were successfully labeled to a 5'-alkanethiol capped oligonucleotides probe that is related to the colitoxin gene. The DNA genetic sensing assay relies on the electrostatic adsorption of target oligonucleotides onto conducting polypyrrole (PPy) surface at the glassy carbon electrode (GCE), and its hybridization to the alloy particle-oligonucleotides DNA probe. Hybridization events between probe and target were monitored by the release of the copper metal atoms anchored on the hybrids by oxidative metal dissolution and the indirectly determination of the solubilized Cu2+ ions by sensitive anodic stripping voltammetry (ASV). The detection limit is 5.0 pmol l(-1) of target oligonucleotides. The Cu@Au core-shell nanoparticles combining the surface modification properties of Au with the good electrochemical activity of Cu core shows their perspective application in the electrochemical DNA hybridization analysis assay.  相似文献   

2.
We have designed a simple and novel electrochemical biosensor based on glassy carbon electrode (GCE) for DNA detection. GCE was modified with reduced graphene oxide (RGO) and gold nanoparticles (AuNPs) by the electrochemical method, which is helpful for immobilization of thiolated bioreceptors. The electrode modification processes were characterized by scanning electron microscopy (SEM) and electrochemical methods. Then a single-stranded DNA (ssDNA) probe for BRCA1 5382 insC mutation detection was immobilized on the modified electrode for a specific time. The experimental conditions, such as probe immobilization time and target DNA (complementary DNA) hybridization time and temperature with probe DNA, were optimized using electrochemical methods. The electrochemical response for DNA hybridization and synthesis was measured using electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV) methods. The calibration graph contains two linear ranges; the first part is in the range of 3.0 × 10−20 to 1.0 × 10−12 M, and the second segment part is in the range of 1.0 × 10−12 to 1.0 × 10−7 M. The biosensor showed excellent selectivity for the detection of the complementary sequences from noncomplementary sequences, so it can be used for detection of breast cancer.  相似文献   

3.
Kang J  Li X  Wu G  Wang Z  Lu X 《Analytical biochemistry》2007,364(2):165-170
DNA hybridization on the Au(nano)-DNA modified glassy carbon electrode (GCE) was investigated. The thiol modified probe oligonucleotides (SH-ssDNA) at the 5' phosphate end were assembled on the Au(nano)-DNA modified GCE surface. The electrochemical response of the probe immobilization and hybridization with target DNA was measured by differential pulse voltammetry (DPV) using methylene blue (MB) as the electroactive indicator. Gold nanoparticles can be dispersed effectively on the GCE surface in the presence of calf thymus DNA. Au(nano)-DNA modified GCE could greatly increase the active sites and enhance the response signal during immobilization and hybridization. The hybridization amount of target DNA could be greatly increased. The linear detection range of Au(nano)-DNA electrode for the complementary 21-mer oligonucleotide (cDNA) was achieved from 1.52 x 10(-10) to 4.05 x 10(-8) mol L(-1). The detection limit could reach the concentration of 10(-10) mol/L.  相似文献   

4.
DNA hybridization and enzymatic digestion for the detection of mutation was investigated on the gold nanoparticles-calf thymus DNA (AuNPs-ctDNA) modified glassy carbon electrode (GCE). The thiol modified probe oligonucleotides (SH-ssDNA) were assembled on the surface of AuNPs-ctDNA modified GCE. The electrochemical response of the electrode was measured by differential pulse voltammetry and cyclic voltammetry. Methylene blue (MB) was used as the electroactive indicator. AuNPs were then dispersed effectively on the GCE surface in the presence of ct-DNA. When hybridization occurred, a decrease in the signal of MB current was observed. The modified electrode was used for the detection of mutations during the enzymatic digestion reaction in DNA. During this reaction, an increase in the signal of MB current was observed. So, the modified SH-ssDNA had a higher electrochemical response on the AuNPs-ctDNA/GCE because of the strong affinity of MB for guanine residues in it. The electrochemical detection of restriction enzyme digestion can provide a simple and practical method for observing single-base mismatches that can help in distinguishing mismatch sequences of DNA from the complementary ones.  相似文献   

5.
A sensitive electrochemical aptasensor for thrombin detection is presented based on the host-guest recognition technique. In this sensing protocol, a 15 based thrombin aptamer (ab. TBA) was dually labeled with a thiol at its 3' end and a 4-((4-(dimethylamino)phenyl)azo) benzoic acid (dabcyl) at its 5' end, respectively, which was previously immobilized on one Au electrode surface by AuS bond and used as the thrombin probe during the protein sensing procedure. One special electrochemical marker was prepared by modifying CdS nanoparticle with β-cyclodextrins (ab. CdS-CDs), which employed as electrochemical signal provider and would conjunct with the thrombin probe modified electrode through the host-guest recognition of CDs to dabcyl. In the absence of thrombin, the probe adopted linear structure to conjunct with CdS-CDs. In present of thrombin, the TBA bond with thrombin and transformed into its special G-quarter structure, which forced CdS-CDs into the solution. Therefore, the target-TBA binding event can be sensitively transduced via detecting the electrochemical oxidation current signal of Cd of CdS nanoparticles in the solution. Using this method, as low as 4.6 pM thrombin had been detected.  相似文献   

6.
Li XM  Zhan ZM  Ju HQ  Zhang SS 《Oligonucleotides》2008,18(4):321-327
A novel label-free electrochemical DNA biosensor based on 4,4'-diaminoazobenzene (4,4'-DAAB) and multiwalled carbon nanotube (MWNT)-modified glassy carbon electrode (GCE) for short DNA sequences related to the hepatitis B virus (HBV) hybridization detection was presented. Differential pulse voltammetry (DPV) was used to investigate hybridization event. The decrease in the peak current of 4,4'-DAAB was observed on hybridization of probe with the target. This electrochemical approach was sequence specific as indicated by the control experiments, in which no peak current change was observed when a noncomplementary DNA sequence was used. Numerous factors affecting the target hybridization were optimized to maximize the sensitivity. Under optimal conditions, this sensor showed a good calibration range between 7.94 x 10(-8) M and 1.58 x 10(-6) M, with HBV DNA sequence detection limit of 1.1 x 10(-8) M.  相似文献   

7.
A microtiter-based assay system is described in which DNA hairpin probes with dangling ends and single-stranded, linear DNA probes were immobilized and compared based on their ability to capture single-strand target DNA. Hairpin probes consisted of a 16 bp duplex stem, linked by a T2-biotin·dT-T2 loop. The third base was a biotinylated uracil (UB) necessary for coupling to avidin coated microtiter wells. The capture region of the hairpin was a 3′ dangling end composed of either 16 or 32 bases. Fundamental parameters of the system, such as probe density and avidin adsorption capacity of the plates were characterized. The target DNA consisted of 65 bases whose 3′ end was complementary to the dangling end of the hairpin or to the linear probe sequence. The assay system was employed to measure the time dependence and thermodynamic stability of target hybridization with hairpin and linear probes. Target molecules were labeled with either a 5′-FITC, or radiolabeled with [γ-33P]ATP and captured by either linear or hairpin probes affixed to the solid support. Over the range of target concentrations from 10 to 640 pmol hybridization rates increased with increasing target concentration, but varied for the different probes examined. Hairpin probes displayed higher rates of hybridization and larger equilibrium amounts of captured targets than linear probes. At 25 and 45°C, rates of hybridization were better than twice as great for the hairpin compared with the linear capture probes. Hairpin–target complexes were also more thermodynamically stable. Binding free energies were evaluated from the observed equilibrium constants for complex formation. Results showed the order of stability of the probes to be: hairpins with 32 base dangling ends > hairpin probes with l6 base dangling ends > 16 base linear probes > 32 base linear probes. The physical characteristics of hairpins could offer substantial advantages as nucleic acid capture moieties in solid support based hybridization systems.  相似文献   

8.
Li GJ  Liu N  Ouyang PK  Zhang SS 《Oligonucleotides》2008,18(3):269-276
A new Cu(II) complex CuL(2)Br(2) (L = azino-di(5,6-azafluorene)-kappa(2)-NN') was synthesized, and a new method of electrochemical probe has been proposed for the determination of hepatitis B virus (HBV) based on its interaction with [CuL(2)](2+). This ligand, containing functional groups, as well as planar aromatic domains, is capable of binding to double-stranded DNA (dsDNA) more efficiently than to single-stranded DNA (ssDNA). Emphasis has been placed on the elucidation of the nature of the interaction by electrochemical techniques. The electroactive [CuL(2)](2+) could be employed as an electrochemical indicator to detect hybridization events in DNA biosensors. These biosensors have been constructed by immobilization of a probe DNA sequence from HBV onto glassy carbon electrode (GCE). After hybridization with the complementary target sequence, [CuL(2)](2+) was accumulated within the dsDNA layer. Electrochemical detection was performed by differential pulse voltammetry over the potential range. Using this approach, complementary target sequences of HBV can be quantified over the range of 1.74 x 10(-9) to 3.45 x 10(-7) M, with a detection limit of 8.32 x 10(-10) M and a linear correlation coefficient of 0.9936.In addition, this approach is capable of detecting hybridization of complementary sequences containing one or three mismatched bases.  相似文献   

9.
In this work, we present an electrochemical DNA sensor based on silver nanoparticles/poly(trans-3-(3-pyridyl) acrylic acid) (PPAA)/multiwalled carbon nanotubes with carboxyl groups (MWCNTs-COOH) modified glassy carbon electrode (GCE). The polymer film was electropolymerized onto MWCNTs-COOH modified electrode by cyclic voltammetry (CV), and then silver nanoparticles were electrodeposited on the surface of PPAA/MWCNTs-COOH composite film. Thiol group end single-stranded DNA (HS-ssDNA) probe was easily covalently linked onto the surface of silver nanoparticles through a 5′ thiol linker. The DNA hybridization events were monitored based on the signal of the intercalated adriamycin by differential pulse voltammetry (DPV). Based on the response of adriamycin, only the complementary oligonucleotides gave an obvious current signal compared with the three-base mismatched and noncomplementary oligonucleotides. Under the optimal conditions, the increase of reduction peak current of adriamycin was linear with the logarithm of the concentration of the complementary oligonucleotides from 9.0 × 10−12 to 9.0 × 10−9 M with a detection limit of 3.2 × 10−12 M. In addition, this DNA sensor exhibited an excellent reproducibility and stability during DNA hybridization assay.  相似文献   

10.
Xia Q  Chen X  Liu JH 《Biophysical chemistry》2008,136(2-3):101-107
A novel DNA hybridization sensor based on nanoparticle CdS modified glass carbon electrode (GCE) was constructed and characterized coupled with Cyclic Voltammogram (CV) and Differential Pulse Voltammogram (DPV) techniques. The mercapto group-linked probe DNA was covalently immobilized onto the CdS layer and exposed to oligonucleotide (ODN) target for hybridization. The structure of DNA sensor was characterized by X-ray diffraction (XRD), field-emission microscopy (FESEM) and X-ray photoelectron spectra (XPS). Sensitive electrical readout achieved by CV and DPV techniques shown that when the target DNA hybridized with probe CdS-ODN conjugates and the double helix formed on the modified electrode, a significant increased response was observed comparing with the bare electrodes. The selectivity of the sensor was tested using a series of matched and certain-point mismatched sequences with concentration grads ranging from 10(-6) microM to 10(1) microM. The signal was in good linear with the minus logarithm of target oligonucleotide concentration with detection limit <1 pM and the optimized target DNA concentration was 10(-6) microM for the signal amplification. Due to great surface properties, the additional negative charges and space resistance of as-prepared CdS nanoparticles, the sensor was able to robustly discriminate the DNA hybridization responses with good sensitivity and stability.  相似文献   

11.
An electrochemical approach for detection of individual single nucleotide polymorphisms (SNPs) based on nucleobase-conjugated apoferritin probe loaded with metal phosphate nanoparticles is reported. Coupling of the nucleotide-modified nanoparticle probe to the mutant sites of duplex DNA was induced by DNA polymerase I (Klenow fragment) to preserve Watson-Crick base-pairing rules. After sequential liquid hybridization of biotinylated DNA probes with mutant DNA and complementary DNA, the resulting duplex DNA helixes were captured to the surface of magnetic beads through a well known and specific biotin-streptavidin affinity binding. For signaling each of eight possible Single-nucleotide polymorphisms (SNPs), Pb, Cu, Cd and Zn phosphate-loaded apoferritin nanoparticle probes were linked to adenosine (A), cytidine (C), guanosine (G), and thymidine (T) mononucleotides, respectively. Monobase-conjugated apoferritin probes were coupled to the mutant sites of the formed duplex DNA in the presence of DNA polymerase. Electrochemical stripping analyses of the metals loaded in apoferritin nanoparticle probes provide a means for detection and quantification of mutant DNA. Each mutation captures different nucleotide-conjugated apoferritin probe and provide a distinct four-potential voltammogram, whose peak potentials reflect the identity of the mismatch. The method is sensitive enough to accurately determine AG mutation, as the most thermodynamically stable mismatch to detect, in the range of 50-600 pM. The proposed protocol provides a simple, fast, cost-effective, accurate and sensitive method for detection of SNPs.  相似文献   

12.
Li XM  Ju HQ  Zhang SS 《Oligonucleotides》2008,18(1):73-80
An electrochemical method was used to probe the interaction between 2-aminophenoxazine-3-one (AP) and the short DNA sequence related to the hepatitis B virus (HBV), and an electrochemical DNA biosensor was developed. The voltammetric signals of AP have been investigated at bare glassy carbon electrode (bare GCE), hybrid double-stranded DNA-modified GCE (dsDNA/GCE), and single-stranded DNA-modified GCE (ssDNA/GCE) by means of differential pulse voltammetry (DPV), and the peak currents increased with respect to the order of electrodes. The extent of hybridization was evaluated on the basis of the difference between signals of AP with a probe before and after hybridization with the complementary sequence. Control experiments with noncomplementary were performed to test the selectivity of the biosensor. With this approach, a sequence of the HBV could be quantified over the range from 3.53 x 10(-7) to 1.08 x 10(-6) M, with a linear correlation of r = 0.9963 and a detection limit of 1.00 x 10(-7) M.  相似文献   

13.
A new acridone derivative 2-nitroacridone (NAD) was synthesized in this paper, and it was found that NAD had excellent electrochemical activity on the glassy carbon electrode (GCE) with a couple reversible redox peaks at 0.051 V and 0.103 V, respectively. Voltammetry was used to investigate the electrochemical behavior of NAD and the interaction between NAD and salmon sperm DNA. In pH 4.0 phosphate buffer solution, the binding ratio between NAD and salmon sperm DNA was calculated to be 2:1 and the binding constant was 3.19 × 105 L/mol. A Chronic Myelogenous Leukemia (CML, Type b3a2) DNA biosensor was developed by immobilizing covalently single-stranded CML DNA fragments to a modified GCE. The surface hybridization of the immobilized single-stranded CML DNA fragment with its complementary DNA fragment was evidenced by electrochemical methods using NAD as a novel electrochemical indicator, with a detection limit of 6.7 × 10−9 M and a linear response range of 1.8 × 10−8 M to 9.1 × 10−8 M for CML DNA. Selective determination of complementary ssDNA was achieved using differential pulse voltammetry (DPV).  相似文献   

14.
Monosuccinyl β-cyclodextrin (succinyl-β-CD) was synthesized and the selectivity to quercetin and rutin of the succinyl-β-CD-modified, multi-wall carbon nanotube (MWNT)-coated, glassy carbon electrode [(succinyl-β-CD + MWNT)/GCE] was investigated. 1H NMR and MALDI-MS data confirmed molecular structure of the synthesized succinyl-β-CD. As a dopant in carboxylated MWNT-modified electrode, succinyl-β-CD clearly separated the peak potential (Ep) of quercetin from that of rutin. The measured peak potential separation (ΔEp) was 110 mV. More favorable complexation between succinyl-β-CD and quercetin may enhance relative selectivity to quercetin of the (succinyl-β-CD + MWNT)/GCE in quercetin-rutin mixture as compared to the β-CD-modified GCE.  相似文献   

15.
We describe the direct electrochemical detection of DNA methylation in relatively long sequences by using a nanocarbon film electrode. The film was formed by employing the electron cyclotron resonance sputtering method and had a nanocrystalline sp2 and sp3 mixed bond structure. Our methylation detection technique measures the differences between the oxidation currents of both 5-methylcytosine and cytosine without a bisulfite reaction or labeling. This was possible because this film electrode has a wide potential window while maintaining the high electrode activity needed to quantitatively detect both bases by direct oxidation. By optimizing the electrode surface conditions using electrochemical pretreatment, we used this film to quantitatively detect single cytosine methylation regardless of the methylation position in the sequence including retinoblastoma gene fragments (∼24mers). This was probably due to the high stability of this film electrode, which we achieved by controlling the surface hydrophilicity to suppress the fouling, and by maintaining electrode activity against all the bases. The pH optimization of the oligonucleotide measurements was also useful for distinguishing both bases separately. Under the optimized conditions, this film electrode allowed us to realize the quantitative detection of DNA methylation ratios solely by measuring methylated 5′-cytosine-phosphoguanosine (CpG) repetition oligonucleotides (60mers) with different methylation ratios.  相似文献   

16.
N-6 methylation of adenine destabilises duplex DNA and this can increase the proportion of DNA that dissociates into single strands. We have investigated utilising this property to measure the DNA adenine methyltransferase-catalyzed conversion of hemimethylated to fully methylated DNA through a simple, direct, fluorescence-based assay. The effects of methylation on the kinetics and thermodynamics of hybridisation were measured by comparing a fully methylated oligonucleotide product and a hemimethylated oligonucleotide substrate using a 13-bp duplex labeled on adjacent strands with a fluorophore (fluorescein) and quencher (dabcyl). Enzymatic methylation of the hemimethylated GATC site resulted in destabilisation of the duplex, increasing the proportion of dissociated DNA, and producing an observable increase in fluorescence. The assay provides a direct measurement of methylation rate in real time and is highly reproducible, with a coefficient of variance over 48 independent measurements of 3.6%. DNA methylation rates can be measured as low as 3.55 ± 1.84 fmol s−1 in a 96-well plate format, and the assay has been used to kinetically characterise the Pyrococcus horikoshii DNA adenine methyltransferase.  相似文献   

17.
We report a novel electrochemical biosensor for direct discrimination of d- and l-mandelic acid (d- and l-MA) in aqueous medium. The glassy carbon electrode (GCE) surface was modified with reduced graphene oxide (rGO) and γ-globulin (GLOB). Electrochemical characterization of the modified electrodes was investigated by cyclic voltammetry and electrochemical impedance spectroscopy. The modified electrode surfaces were also characterized by scanning electron microscopy. Electrochemical response of the prepared electrode (GCE/rGO/GLOB) for discrimination of d- and l-MA enantiomers was investigated by cyclic voltammetry and was compared with bare GCE in the concentration range of 2 to 10 mM. Whereas the bare GCE showed no electrochemical response for the MA enantiomers, the GCE/rGO/GLOB electrode exhibited direct and selective discrimination with different oxidation potential values of 1.47 and 1.71 V and weak reduction peaks at potential values of −1.37 and −1.48 V, respectively. In addition, electrochemical performance of the modified electrode was investigated in mixed solution of d- and l-MA. The results show that the produced electrode can be used as electrochemical chiral biosensor for MA.  相似文献   

18.
A sensitive electrochemical DNA detection method for the diagnosis of sexually transmitted disease (STD) caused by Chlamydia trachomatis was developed. The method utilizes a DNA-intercalating agent and a peroxidase promoted enzymatic precipitation reaction and involves the following steps. After hybridization of the target C. trachomatis gene with an immobilized DNA capture probe on a gold electrode surface, the biotin-tagged DNA intercalator (anthraquinone) was inserted into the resulting DNA duplex. Subsequently, the polymeric streptavidin/peroxidase complex was applied to the biotin-decorated electrode. Peroxidase catalyzed 4-chloronaphthol to produce insoluble product, which is precipitated on the electrode surface in the presence of hydrogen peroxide. Cyclic voltammograms with the gold electrode exhibited a peak current of ferrocenemethanol in electrolyte, which decreased in a proportional way to increasing concentration of target DNA owing to insulation of electrode surface by the growing insoluble precipitate. Using this strategy, we were able to detect picomolar concentrations of C. trachomatis gene in a sample taken from a real patient.  相似文献   

19.
Molecular beacons are stem–loop hairpin oligonucleotide probes labeled with a fluorescent dye at one end and a fluorescence quencher at the other end; they can differentiate between bound and unbound probes in homogeneous hybridization assays with a high signal-to-background ratio and enhanced specificity compared with linear oligonucleotide probes. However, in performing cellular imaging and quantification of gene expression, degradation of unmodified molecular beacons by endogenous nucleases can significantly limit the detection sensitivity, and results in fluorescence signals unrelated to probe/target hybridization. To substantially reduce nuclease degradation of molecular beacons, it is possible to protect the probe by substituting 2′-O-methyl RNA for DNA. Here we report the analysis of the thermodynamic and kinetic properties of 2′-O-methyl and 2′-deoxy molecular beacons in the presence of RNA and DNA targets. We found that in terms of molecular beacon/target duplex stability, 2′-O-methyl/RNA > 2′-deoxy/RNA > 2′-deoxy/DNA > 2′-O-methyl/DNA. The improved stability of the 2′-O-methyl/RNA duplex was accompanied by a slightly reduced specificity compared with the duplex of 2′-deoxy molecular beacons and RNA targets. However, the 2′-O-methyl molecular beacons hybridized to RNA more quickly than 2′-deoxy molecular beacons. For the pairs tested, the 2′-deoxy-beacon/DNA-target duplex showed the fastest hybridization kinetics. These findings have significant implications for the design and application of molecular beacons.  相似文献   

20.
We have designed an electrochemical DNA biosensor based on stem-loop structured probes for enzymatic detection of Pseudomonas aeruginosa 16S ribosomal RNA (rRNA) in composting degradation. The probe modified with a thiol at its 5′ end and a biotin at its 3′ end was immobilized on a gold electrode through self-assembly. The stem-loop structured probes were “closed” when target was absent, then the hybridization of the target induced the conformational changes to “open”, along with the biotin at its 3′ end binding with streptavidin-horseradish peroxidase (HRP), and subsequent quanti?cation of the target was detected via electrochemical detecting the enzymatic product in the presence of substrate. Under the optimum experiment conditions, the amperometric current response to HRP-catalyzed reaction was linearly related to the logarithm of the target nucleic acid concentration, ranging from 0.3 and 600 pg/μL, with the detection limit of 0.012 pg/μL. A correlation coefficient of 0.9960 was identified. The 16S rRNA extracted from P. aeruginosa was analyzed by this proposed sensor. The results were in agreement with the reference values deduced from UV spectrometric data. The biosensor was indicative of good precision, stability, sensitivity, and selectivity.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号