首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A liquid chromatography–tandem mass spectrometry (LC–MS/MS) method was developed for the simultaneous determination of eight β-lactam antibiotics, including ampicillin, cefazolin, cefepime, cefmetazole, cefotaxime, doripenem, meropenem, and piperacillin, in human serum. Sample specimens were subjected to solid phase extraction (SPE) using Waters Oasis® HLB cartridges (30 mg). Chromatographic separation was performed with a high-resolution octadecyl silica column compatible with hydrophilic compounds, using a gradient of 10 mM aqueous ammonium formate containing 0.1% formic acid-methanol. Antibiotics were detected by a triple quadrupole mass spectrometer (MS/MS) with electrospray ionization and quantified by the multiple reaction monitoring mode. A total run time of 13 min was applied. Linearity in the calibration was obtained over a range of 0.1–50 μg/mL of the β-lactam antibiotics, except for doripenem. The lower limit of quantification was 0.005–0.5 μg/mL, using 50 μL serum. The recovery rate exceeded 80.2% for these analytes, except for doripenem (49.1%) and meropenem (62.3%). The present method is applicable to routine therapeutic monitoring of β-lactam antibiotics in clinical practice.  相似文献   

2.
Aβ1-42 measurement in CSF is an important biochemical marker for Alzheimer disease (AD). However, our understanding of why this biomarker is predictive and why it is often difficult to measure in a reproducible fashion is still lacking. To study these questions, the concentration of Aβ1-42 in CSF was compared before and after denaturation with 6M guanidine and reverse-phase HPLC. Measurement of the Aβ1-42 after denaturation and reverse-phase HPLC demonstrated that considerably more Aβ1-42 was present in CSF than revealed when assaying non-denatured CSF. A comparison of Aβ1-42 concentrations before and after HPLC in AD CSF with that in normal controls suggested that matrix interference may affect the differentiation between the diagnostic groups. A similar effect was observed with dilutions of crude CSF. Together, these results suggested that at least part of the mechanism by which low Aβ1-42 concentrations in CSF function as a biomarker of AD is related to matrix components which preferentially hide a portion of the Aβ1-42 from detection in AD CSF. In contrast, we show that the association of the APOEε4 allele with lower Aβ1-42 concentrations in CSF is preserved even after denaturation and HPLC. A similar relationship between the presence of the APOEε4 allele and lower concentrations of Aβ1-40 was also apparent, thereby generating similar ratios of Aβ1-42/ Aβ1-40 across the APOE genotypes. The results from the present study suggested that Aβ1-42 in CSF functions as a biomarker of AD in tandem with other CSF matrix components that are increased in AD CSF. Further studies are needed to identify which matrix factors (e.g. binding of Aβ to proteins) underlie the increased detection of Aβ1-42 concentrations after denaturation and HPLC. The data also suggested that denaturation and HPLC of CSF may be a useful approach for studies using Aβ1-42 as a pharmacodynamic marker or in other paradigms where measurement of total non-covalently bound Aβ1-42 is required.  相似文献   

3.
A liquid chromatographic–mass spectrometric (LC–MS) assay was developed and validated for the determination of itraconazole (ITZ) in rat heparinized plasma using reversed-phase HPLC combined with positive atmospheric pressure ionization (API) mass spectrometry. After protein precipitation of plasma samples (0.1 ml) with acetonitrile containing nefazodone as an internal standard (I.S.), a 50-μl aliquot of the supernatant was mixed with 100 μl of 10 mM ammonium formate (pH 4.0). An aliquot of 25 μl of the mixture was injected onto a BDS Hypersil C18 column (50×2 mm; 3 μm) at a flow-rate of 0.3 ml/min. The mobile phase comprising of 10 mM ammonium formate (pH 4) and acetonitrile (60:40, v/v) was used in an isocratic condition, and ITZ was detected in single ion monitoring (SIM) mode. Standard curves were linear (r2≥0.994) over the concentration range of 4–1000 ng/ml. The mean predicted concentrations of the quality control (QC) samples deviated by less than 10% from the corresponding nominal values; the intra-assay and inter-assay precision of the assay were within 8% relative standard deviation. Both ITZ and I.S. were stable in the injection solvent at room temperature for at least 24 h. The extraction recovery of ITZ was 96%. The validated assay was applied to a pharmacokinetic study of ITZ in rats following administration of a single dose of itraconazole (15 mg/kg).  相似文献   

4.
A simple and rapid method with high performance liquid chromatography/tandem mass spectrometry is described for the quantitation of the kinase inhibitor sorafenib and its active metabolite sorafenib N-oxide in human plasma. A protein precipitation extraction procedure was applied to 50 μL of plasma. Chromatographic separation of the two analytes, and the internal standard [2H313C]-sorafenib, was achieved on a C18 analytical column and isocratic flow at 0.3 mL/min for 4 min. Mean within-run and between-run precision for all analytes were <6.9% and accuracy was <5.3%. Calibration curves were linear over the concentration range of 50–10,000 ng/mL for sorafenib and 10–2500 ng/mL for sorafenib N-oxide. This method allows a specific, sensitive, and reliable determination of the kinase inhibitor sorafenib and its active metabolite sorafenib N-oxide in human plasma in a single analytical run.  相似文献   

5.
A sensitive and selective method for the determination of domperidone in human breast milk and serum has been developed. The same method may be successfully applied to both matrices to a lower limit of quantitation of 0.5 ng/ml. Samples are processed by a liquid–liquid extraction, and analyzed by LC–ESI-MS in positive ion mode. There was no interference, on the domperidone quantitation, from over 30 drugs. Samples from patients, at various times post-dose, were analyzed and a large number showed significant levels of domperidone in the breast milk as well as in the serum.  相似文献   

6.
Alzheimer's disease (AD) is characterized by the massive deposition in the brain of the 40-42-residue amyloid beta protein (A(beta)). While A(beta)1-40 predominates in the vascular system, A(beta)1-42 is the major component of the senile plaques in the neuropil. The concentration of both A(beta) species required to form amyloid fibrils in vitro is micromolar, yet soluble A(betas) found in normal and AD brains are in the low nanomolar range. It has been recently proposed that the levels of A(beta) sufficient to trigger amyloidogenesis may be reached intracellularly. To study the internalization and intracellular accumulation of the major isoforms of A(beta), we used THP-1 and IMR-32 neuroblastoma cells as models of human monocytic and/or macrophagic and neuronal lineages, respectively. We tested whether these cells were able to internalize and accumulate 125I-A(beta)1-40 and 125I-A(beta)1-42 differentially when offered at nanomolar concentrations and free of large aggregates, conditions that mimic a prefibrillar stage of A(beta) in AD brain. Our results showed that THP-1 monocytic cells internalized at least 10 times more 125I-A(betas) than IMR-32 neuroblastoma cells, either isolated or in a coculture system. Moreover, 125I-A(beta)1-42 presented a higher adsorption, internalization, and accumulation of undigested peptide inside cells, as opposed to 125I-A(beta)1-40. These results support that A(beta)1-42, the major pathogenic form in AD, may reach supersaturation and generate competent nuclei for amyloid fibril formation intracellularly. In light of the recently reported strong neurotoxicity of soluble, nonfibrillar A(beta)1-42, we propose that intracellular amyloidogenesis in microglia is a protective mechanism that may delay neurodegeneration at early stages of the disease.  相似文献   

7.
A liquid chromatographic-tandem mass spectrometric (LC–MS–MS) method with a rapid and simple sample preparation was developed for the determination of scopolamine in biological fluids. Scopolamine and the internal standard atropine in serum samples were extracted and cleaned up by using an automated solid phase extraction method. Microdialysis samples were directly injected into the LC–MS system. The mass spectrometer was operated in the multi reaction monitoring mode. A good linear response over the range of 20 pg/ml to 5 ng/ml was demonstrated. The accuracy for added scopolamine ranged from 95.0 to 104.0%. The lower limit of quantification was 20 pg/ml. This method is suitable for pharmacokinetic studies.  相似文献   

8.
The role of leukotrienes (LTs) in airway inflammatory diseases, such as asthma, has been extensively reported. The measurement of LTs in sputum supernatants, which is commonly done via enzyme immunoassays (EIAs), may prove to be useful for assessing airway inflammation. Despite the many advantages of EIA, these methods suffer from a lack of selectivity. Therefore, a selective and reliable method for the analysis of LTs in human sputum is needed. In this study we developed and validated a sensitive and specific method using ultra high pressure liquid chromatography–tandem mass spectrometry (UHPLC–MS/MS), to measure simultaneously cysteinyl leukotrienes (CysLTs) and leukotriene B4 (LTB4) in human sputum. Sputum supernatants obtained by ultracentrifugation were stabilized by protease inhibitors, spiked with stable isotopic internal standards, and subjected to solid phase extraction (SPE) and UHPLC separation. Multiple reaction monitoring (MRM) transitions were optimized and measured on a mass spectrometer. The limit of detection (LOD) for LTE4 and LTB4 was 9.8 and 19.5 pg/mL, respectively. The lower limit of quantitation (LLOQ) for LTE4 and LTB4 was 19.5 and 39.0 pg/mL, respectively. The dynamic range of the LTE4 assay was from 9.8 to 5000 pg/mL, whereas for the LTB4 assay was from 19.5 to 10,000 pg/mL. The intra- and inter-day % coefficient of variation (%CV) was <6.5% and <10%, for both LTE4 and LTB4, respectively. Spike recovery ranged from 105% to 111% for both analytes. In addition, twenty-two sputum samples were analyzed for cysLTs and LTB4. Fourteen of these samples were purchased commercially and eight were collected during the course of a clinical trial. LTB4 was detectable in all samples tested and it ranged from 79 to 7220 pg/mL. LTE4 was detectable in most of the sputum samples (12.3–891 pg/mL), whereas LTC4 and LTD4 were below limit of detection for majority of sputum samples. The in vitro conversion of LTC4 and LTD4 into LTE4 was observed. The measurement of LTB4 was sensitive to low pH and high temperature. The use of UHPLC–MS/MS method will allow a more accurate and reliable quantitation of LTs in human sputum, which in turn, may lead to a better understanding of the role of LTs in airway disease pathways and the application in associated clinical treatments.  相似文献   

9.
A rapid, specific and sensitive liquid chromatography–electrospray ionization-tandem mass spectrometry method was developed and validated for determination of cymipristone in human plasma. Mifepristone was used as the internal standard (IS). Plasma samples were deproteinized using methanol. The compounds were separated on a ZORBAX SB C18 column (50 mm × 2.1 mm i.d., dp 1.8 μm) with gradient elution at a flow-rate of 0.3 ml/min. The mobile phase consisted of 10 mM ammonium acetate and acetonitrile. The detection was performed on a triple-quadruple tandem mass spectrometer by selective reaction monitoring (SRM) mode via electrospray ionization. Target ions were monitored at [M+H]+ m/z 498  416 and 430  372 in positive electrospray ionization (ESI) mode for cymipristone and IS, respectively. Linearity was established for the range of concentrations 0.5–100 ng/ml with a coefficient correlation (r) of 0.9996. The lower limit of quantification (LLOQ) was identifiable and reproducible at 0.5 ng/ml. The validated method was successfully applied to study the pharmacokinetics of cymipristone in healthy Chinese female subjects.  相似文献   

10.
A rapid liquid chromatography–tandem mass spectrometry (LC–MS/MS) method was developed and validated for the determination of picamilon concentration in human plasma. Picamilon was extracted from human plasma by protein precipitation. High performance liquid chromatography separation was performed on a Venusil ASB C18 column with a mobile phase consisting of methanol ?10 mM ammonium acetate–formic acid (55:45:01, v/v/v) at a flow rate of 0.65 ml/min. Acquisition of mass spectrometric data was performed in selected reaction monitoring mode, using the transitions of m/z 209.0  m/z (78.0 + 106.0) for picamilon and m/z 152.0  m/z (93.0 + 110.0) for paracetamol (internal standard). The method was linear in the concentration range of 1.00–5000 ng/ml for the analyte. The lower limit of quantification was 1.00 ng/ml. The intra- and inter-assay precision were below 13.5%, and the accuracy was between 99.6% and 101.6%. The method was successfully applied to characterize the pharmacokinetic profiles of picamilon in healthy volunteers. This validated LC–MS/MS method was selective and rapid, and is suitable for the pharmacokinetic study of picamilon in humans.  相似文献   

11.
Cholesterol plays an important role in the interaction of Alzheimer’s amyloid beta (Aβ) with cell membranes, an important event in Aβ-induced cytotoxicity. However, it is not fully understood how cholesterol influences the association of Aβ with membrane lateral compartments. We have shown that by modulating membrane fluidity, cholesterol decreased peptide localization in solid-ordered domains and increased that in liquid-ordered domains. It changed the amount of Aβ associating with liquid-disordered (Ld) phase with different tendencies depending on the composition of heterogeneous membrane systems. 7-Ketocholesterol, an oxidized derivative of cholesterol, majorly enhanced the fluidity of and Aβ interaction with Ld phase. These findings are useful for clarifying the impact of cholesterol and its oxidation in Aβ-induced toxicity.  相似文献   

12.
BackgroundAnalysis of sialic acid (SA) metabolites in cerebrospinal fluid (CSF) is important for clinical diagnosis. In the present study, a high-performance liquid chromatography–tandem mass spectrometry (HPLC/MS/MS) method for free sialic acid (FSA) and total sialic acid (TSA) in human CSF was validated.MethodsThe method utilized a simple sample-preparation procedure of protein precipitation for FSA and acid hydrolysis for TSA. Negative electrospray ionisation was used to monitor the transitions m/z 308.2  87.0 (SA) and m/z 311.2  90.0 (13C3-SA). Conjugated sialic acid (CSA) was calculated by subtracting FSA from TSA. We established reference intervals for FSA, TSA and CSA in CSF in 217 control subjects. The method has been applied to patients’ samples with known differences in SA metabolites like meningitis (n = 6), brain tumour (n = 2), leukaemia (n = 5), and Salla disease (n = 1).ResultsLimit of detection (LOD) was 0.54 μM for FSA and 0.45 μM for TSA. Intra- and inter-assay variation for FSA (21.8 μM) were 4.8% (n = 10) and 10.4% (n = 40) respectively. Intra- and inter-assay variation for TSA (35.6 μM) were 9.7% (n = 10) and 12.8% (n = 40) respectively. Tested patients showed values of TSA above established reference value.ConclusionThe validated method allows sensitive and specific measurement of SA metabolites in CSF and can be applied for clinical diagnoses.  相似文献   

13.
Pan J  Han J  Borchers CH  Konermann L 《Biochemistry》2012,51(17):3694-3703
Aβ peptides can assemble into amyloid fibrils, which represent one of the hallmarks of Alzheimer's disease. Recent studies, however, have focused on the behavior of small soluble Aβ oligomers that possess a much greater neurotoxicity than mature fibrils. The structural characterization of these oligomers remains difficult because of their highly dynamic and polymorphic nature. This work explores the behavior of Aβ(1-40) in a slightly basic solution (pH 9.3) at a low salt concentration (10 mM ammonium acetate). These conditions lead to the formation of small oligomers, without any signs of fibrillation for several hours. The structure and dynamics of these oligomers were characterized by circular dichroism spectroscopy, size exclusion chromatography, and millisecond time-resolved hydrogen exchange mass spectrometry (MS). Our results reveal rapid interconversion between Aβ(1-40) oligomers and monomers. The mole fraction of monomeric molecules is on the order of 40%. Oligomers consist of ~4 Aβ(1-40) molecules on average, and the resulting assemblies have a predominantly β-sheet secondary structure. Hydrogen exchange proceeds in the EX1 regime. This feature allows the application of conformer-specific top-down MS. Electron capture dissociation is used for interrogating the deuteration behavior of the Aβ(1-40) oligomers. This approach provides a spatial resolution of ~2 residues. The backbone amide deuteration pattern uncovered in this way is consistent with a β-turn-β motif for L17-M35. The N-terminus is involved in hydrogen bonding, as well, whereas protection gradually tapers off for C-terminal residues 35-40. Our data are consistent with earlier proposals, according to which Aβ(1-40) oligomers adopt a β-barrel structure. In general terms, this study demonstrates how top-down MS with precursor ion selection can be employed for structural studies of specific protein conformers within a heterogeneous mix.  相似文献   

14.
A highly efficient, selective and specific method for simultaneous quantitation of triprolidine and pseudoephedrine in human plasma by liquid chromatography–ion trap-tandem mass spectrometry coupled with electro spray ionization (LC–ESI-ion trap-tandem MS) has been validated and successfully applied to a clinical pharmacokinetic study. Both targeted compounds together with the internal standard (gabapentin) were extracted from the plasma by direct protein precipitation. Chromatographic separation was achieved on a C18 ACE® column (50.0 mm × 2.1 mm, 5 μm, Advance Chromatography Technologies, Aberdeen, UK), using an isocratic mobile phase, consisting of water, methanol and formic acid (55:45:0.5, v/v/v), at a flow-rate of 0.3 mL/min. The transition monitored (positive mode) was m/z 279.1  m/z 208.1 for triprolidine, m/z 165.9  m/z 148.0 for pseudoephedrine and m/z 172.0  m/z 154.0 for gabapentin (IS). This method had a chromatographic run time of 5.0 min and a linear calibration curves ranged from 0.2 to 20.0 ng/mL for triprolidine and 5.0–500.0 ng/mL for pseudoephedrine. The within- and between-batch accuracy and precision (expressed as coefficient of variation, %C.V.) evaluated at four quality control levels were within 94.3–106.3% and 1.0–9.6% respectively. The mean recoveries of triprolidine, pseudoephedrine and gabapentin were 93.6, 76.3 and 82.0% respectively. Stability of triprolidine and pseudoephedrine was assessed under different storage conditions. The validated method was successfully employed for the bioequivalence study of triprolidine and pseudoephedrine formulation in twenty six volunteers under fasting conditions.  相似文献   

15.
A previously described method for the determination of GABA in CSF has been expanded to include both GABA and β-ALA, using a single GC–MS analysis. A stable isotope labelled internal standard for β-ALA was synthesised to achieve accurate quantification. This new combined method expands the diagnostic power compared to an isolated GABA measurement. Control values for free and total GABA and free and total β-ALA are described. Age <2 years: free GABA 0.017–0.067 μM, total GABA 4.2–13.4 μM; free β-ALA 0.049–0.11 μM, total β-ALA 2.1–4.6 μM. Age >2 years: free GABA 0.032–0.17 μM, total GABA 3.3–12.2 μM; free β-ALA 0.021–0.058 μM, total β-ALA 0.91–3.5 μM.  相似文献   

16.
A molecularly imprinted polymer (MIP) using zidovudine (AZT) as template and methacrylic acid as monomer was prepared. The synthesis of the MIP was performed in acetonitrile. The synthesized material was then tested for the solid-phase extraction of AZT from different media (pure organic solvents and hydro-organic mixtures). An optimised procedure was developed for the selective extraction of AZT with a recovery of 96% using the MIP and only 3% on a non-imprinted polymer used as control polymer. A specific capacity of 0.2 μmol g?1 was determined. The specificity of the MIP was evaluated by studying the retention behaviour of two others nucleoside analogues. The feasibility of the MIP to selectively extract AZT and stavudine (d4T) from human serum was also demonstrated with recoveries of 80 and 85% respectively. The lower limit of quantification (LLOQ) and the lower limits of detection (LLOD) for AZT were 5.10?7 and 10?7 M respectively.  相似文献   

17.
A sensitive and specific assay of imidapril and its active metabolite, imidaprilat, in human plasma has been developed. This method is based on rapid isolation and high-performance liquid chromatography (HPLC)–electrospray ionization (ESI)-tandem mass spectrometry (MS–MS). Imidapril and imidaprilat were isolated from human plasma using OASIS HLB (solid-phase extraction cartridge), after deproteinization. The eluent from the cartridge was evaporated to dryness, and the residue was reconstituted in mobile phase and injected into the HPLC–ESI-MS–MS system. Each compound was separated on a semi-micro ODS column in acetonitrile–0.05% (v/v) formic acid (1:3, v/v). The selected ion monitoring using precursor→product ion combinations of m/z 406→234 and 378→206, was used for determination of imidapril and imidaprilat, respectively. The linearity was confirmed in the concentration range of 0.2 to 50 ng/ml in human plasma, and the precision of this assay, expressed as a relative standard deviation, was less than 13.2% over the entire concentration range with adequate assay accuracy. The HPLC–ESI-MS–MS method correlates well with the radioimmunoassay method, therefore, it is useful for the determination of imidapril and imidaprilat with sufficient sensitivity and specificity in clinical studies.  相似文献   

18.
Quantitative analysis of two opioid peptides, DSLET [(d-Ser2)Leu-enkephalin-Thr6] and Met-enkephalin-Arg-Gly-Leu, was performed using microbore liquid chromatography interfaced to electrospray ionization tandem mass spectrometry. Validation of the methodology was demonstrated for each peptide in plasma. Quantitative analyses were performed through the use of a deuterium labelled peptide analog as an internal standard. Linearity was observed for the analysis of DSLET (5–1000 ng/ml) and Met-enkephalin-Arg-Gly-Leu (1–1000 ng/ml) in plasma with a limit of detection of 0.25 ng/ml for Met-enkephalin-Arg-Gly-Leu and 1.0 ng/ml for DSLET. In general, the observed concentrations showed good reproducibility with coefficients of variation of within 15%. In the concentration range studied, only 0.5 ml of plasma was required for optimal detection of Met-enkephalin-Arg-Gly-Leu and 0.25 ml for DSLET. Application of this method was demonstrated by studying the disposition of DSLET in a rat. DSLET administered to a rat exhibited a short half-life and a high clearance value.  相似文献   

19.
A new and sensitive high performance liquid chromatography (HPLC) separation procedure coupled with tandem mass spectroscopy (MS and MS(2)) detection was developed to identify for the first time the oxidation products of 5β-scymnol [(24R)-(+)-5β-cholestan-3α,7α,12α,24,26,27-hexol] catalysed by bacterial hydroxysteroid dehydrogenase (HSD) reactions in vitro. The authentic scymnol (MW 468) standard yielded a protonated molecular ion [M+H](+) at m/z 469 Da, and higher mass adduct ions attributed to [M+NH(4)](+) (m/z 486), [M+H+CH(3)OH](+) (m/z 501) and [M+H+CH(3)COOH](+) (m/z 530). (24R)-(+)-5β-Cholestan-3-one-7α,12α,24,26,27-pentol (3-oxoscymnol, m/z 467 Da, relative retention time (RRT)=0.89) was identified as the principle molecular species of scymnol in the reaction with 3α-HSD pure enzyme. [S](0.5) for the reaction of 3α-HSD with scymnol as substrate was 0.7292 mM. (24R)-(+)-5β-cholestan-7-one-3α,12α,24,26,27-pentol (7-oxoscymnol, m/z 467 Da, RRT=0.79) and (24R)-(+)-5β-cholestan-12-one-3α,7α,24,26,27-pentol (12-oxoscymnol, m/z 467 Da, RRT=0.81) were similarly identified as principle molecular species in the respective 7α-HSD and 12α-HSD reactions. Polarity of the oxoscymnol species was established as 7-oxoscymnol>12-oxoscymnol>3-oxoscymnol>scymnol (in order from most polar to least polar). Confirmation that 5β-scymnol is an oxidative substrate for steroid-metabolising enzymes was made possible by the use of sophisticated liquid chromatography-mass spectrometry (LC-MS) techniques that will likely provide the basis for further exploration of scymnol as a therapeutic compound.  相似文献   

20.
Protein S-glutathionylation is a posttranslational modification that links oxidative stimuli to reversible changes in cellular function. Protein–glutathione mixed disulfide (PSSG) is commonly quantified by reduction of the disulfide and detection of the resultant glutathione species. This methodology is susceptible to contamination by free unreacted cellular glutathione (GSH) species, which are present in 1000-fold greater concentration. A liquid chromatography–tandem mass spectrometry (LC–MS/MS)-based method was developed for quantification of glutathione and glutathione disulfide (GSSG), which was used for the determination of PSSG in biological samples. Analysis of rat liver samples demonstrated that GSH and GSSG coprecipitated with proteins similar to the range for PSSG in the sample. The use of [13C2,5N]GSH and [13C4,5N2]GSSG validated these results and demonstrated that the release of GSH from PSSG did not occur during sample preparation and analysis. These data demonstrate that GSH and GSSG contamination must be accounted for when determining PSSG content in cellular/tissue preparations. A protocol for rinsing samples to remove the adventitious glutathione species is demonstrated. The fragmentation patterns for glutathione were determined by high-resolution mass spectrometry, and candidate ions for detection of PSSG on protein and protein fragments were identified.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号